Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Similar documents
Certi 堵脝 cation Record

C E R T I F I C A T E O F C O M P L I A N C E

Certificate of Compliance

C E R T I F I C A T E O F C O M P L I A N C E

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

C E R T I F I C A T E O F C O M P L I A N C E

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany

Self-protected Combination Starters System PKZ 2-SP

Low-Peak 600V Class RK1

C E R T I F I C A T E O F C O M P L I A N C E

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

TeSys Motor Starter Solutions for the North American Market

Product Specification Sheet #3LD2.1

Bulletin 190-M Compact Starters. Selection Guide

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Magnetic Overload Relays

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Softstarters. Softstarters Power electronic brakes Type PEB

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

File E14900 Project 98NK January 11, 1999 REPORT MOTOR CONTROLLERS MAGNETIC. Siemens Energy & Automation Inc. Batavia, IL

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Switches Unlimited Phone: * Fax:

For Options, Modifications and Accessories, see pages Discount Schedule A6

Short-Circuit Current Ratings

Technical data OT16E3 OT160E3 UL & CSA

Page 2-4 Page 2-8. Page Page 2-13

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940

Certificate of Compliance

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

KT4 Manual Motor Starter

C E R T I F I C A T E O F C O M P L I A N C E

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

[V] Common Control Transformer Control (See page 1-78 Note)

Certificate of Compliance

Selection Guide Motor Control Device Solutions

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

MERCURY TO METAL CONTACTORS AND RELAYS

SD Series Non-Fused Load Switches

4.1. Definite Purpose Contactors and Starters. Contents

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Overload Relay Heater Tables

NEMA Contactors & Starters (Freedom)

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

Bulletin 140M Motor Protectors

Bussmann series Quik-Spec Coordination Panelboard

SECTION MOTOR CONTROL

A200 NEMA Contactors and Starters A200

C E R T I F I C A T E O F C O M P L I A N C E

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

TeSys D Overload Relays

AS-i Metal Enclosed DOL Starters

Ideal for use as a manual starter

Enclosed Molded Case Circuit Breakers

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

Power electronic brakes

Instructions for Type W Three Phase, Standalone Overload Relays, Size 1 through 6

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Enclosed Rotary Switch Product Specification Sheets Table of Contents

UL 508 Non-Fusible Disconnect Switches

Certificate of Compliance

NEMA Full Voltage Power Devices. Section 1. Control Catalog 1-1

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

N0N A 250V One-Time Class H Fuse

Low voltage switch gear

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

A. Submit manufacturer's literature and technical data before starting work.

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

UL 508 Non-Fusible Disconnect Switches

XMC0 Series DEFINITE PURPOSE CONTACTORS

3 - Protection components Motor circuit-breakers

Application Description

Type E/F Simplex & Duplex Pump Controllers

CI-TI Contactors and motor starters Types CI 61 - CI 98

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

Thermal Overload Relays

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

Section Contents. Disconnect Switches

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

Selection Guide. Control Circuit and Load Protection

Data Sheet Manual Motor Starter Ex9S32 Series

MAGNETIC MOTOR STARTERS

Quik-Spec Electrical Gear

3. Coils shall be of molded construction

Technical Information

Low Voltage Fuses For Motor Protection

Transcription:

Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic File Number 060905_S_000 http://www.csagroup.org/services industries/product listing/certificate/?060905_s_000 3211 04 1/12

AC starters: Class 8536 non reversing, Class 8736 reversing, Class 8810 two speed; and AC Contactors: Class 8502 non reversing, Class 8702, reversing: Size 00, across the line, magnetically operated, rated 10 Amax (open) or 9 Amax (enclosed), single phase: 1/3hp, 115V; 1hp, 230V; three phase: 1.5hp, 200V; 1.5hp, 230V; 1.5hp, 380V; 2hp, 575V, three phase. Standard fault shortcircuit withstand rating: 5kA RMS sym. 600Vac; High fault short circuit withstand rating: 100kA RMS sym. 600Vac max. Size 0, across the line, magnetically operated, rated 20 Amax (open) or 18 Amax (enclosed), single phase: 1hp, 115V; 2hp, 230V; three phase: 3hp, 200V; 3hp, 230V; 5hp, 380V; 5hp, 575V, three phase. Size 1, across the line, magnetically operated, rated 30 Amax (open) or 27 Amax (enclosed), single phase: 2hp, 115V; 3hp, 230V; three phase: 7.5hp, 200V; 7.5hp, 230V; 10hp, 380V; 10hp, 575V, three phase. Standard fault short circuit withstand rating: 5kA RMS sym. 600Vac; High fault short circuit withstand rating: 100kA Size 1P, across the line, magnetically operated, rated 36 Amax (open) or 30 Amax (enclosed), single phase: 3hp, 115V; 5hp, 230V. Size 2, across the line, magnetically operated, open type, rated 45A (max), 3 hp, 115V and 7.5 hp, 230V, single phase, 10 hp, 200V, 15 hp, 230V, 25 hp, 380V, 25 hp, 575V, three phase. Size 3, across the line, magnetically operated, open type, rated 90A (max), 7.5 hp, 115V; 15 hp, 230V single phase; 25 hp, 200V; 30 hp, 230V; 50 hp, 380V; 50 hp, 575V, three phase. Size 4, across the line, magnetically operated, open type, rated 135A (max), 40 hp 200V, 50 hp 230V, 75 hp 380V, 100 hp 575V, three phase. Standard fault short circuit withstand rating: 10kA RMS sym. 600Vac; High fault short circuit withstand rating: 100kA Size 5, across the Line, magnetically operated, open type, rated 270A (max), 75 hp, 200V; 100 hp, 230V; 150 hp, 380V; 200 hp, 575V, three phase. Standard fault short circuit withstand rating: 10kA RMS sym. 600Vac; High fault short circuit withstand rating: 100kA Size 6, across the line, magnetically operated, open type, rated 540A (max), 150 hp, 200V, 200 hp, 230V, 300 hp, 380V, 400 hp, 575V, three phase. Standard fault short circuit withstand rating: 18kA RMS sym. 600Vac; High fault short circuit withstand rating: 100kA AC Contactors: Class 8502, Type REQ 2617 G1, non reversing, across the line, magnetically operated, open type, rated 20 hp, 230V, 30 hp, 460V, three phase. AC Contactors: Class 8502, Type REQ 2686 G1, non reversing, across the line, magnetically operated, open type, rated 40 hp, 230V; 75 hp, 460V, three phase. AC starters: Class 8536 non reversing, Class 8736 reversing, Class 8810 two speed; and AC Contactors : Class 8502 non reversing, Class 8702, reversing: Size 7, across the line, magnetically operated, open type, rated 750A (max), 250 hp, 200V, 300 hp, 230V, 450 hp, 380V, 600 hp, 575V, three phase. http://www.csagroup.org/services industries/product listing/certificate/?060905_s_000 3211 04 Class 8502 contactors, Types PG, PJ and PK (with suffixes), Series A and B, open or enclosed types, 3 pole, may be 2/12

Class 8502 contactors, Types PG, PJ and PK (with suffixes), Series A and B, open or enclosed types, 3 pole, may be provided with auxiliary contacts, coils 24 600V ac, 50/60Hz, for max contact ratings see Table 1. Table 1: Horsepower Current (A) 3 phase Type 600V 200 230V 460V 575V PG1 80 20 40 50 PG3 100 25 50 60 PJ1 125 30 60 75 PJ3 160 40 75 100 PJ5 160 50 100 125 PK1 200 60 125 150 PK3 250 75 150 200 PK5 315 100 200 250 Class 8702, reversing contactors, open or enclosed, Sizes 00 to 6. Class 8702, reversing contactors, open or enclosed, Size 7. AC across the line contactors and starters for crane and hoist application, max ratings as follows: Designation Type Size No of Poles Amps 230V 460V Contactors U 11454 03 Non Rev. 0 3 20 3 5 U 11454 13 " 1 " 30 7 1/2 10 http://www.csagroup.org/services industries/product listing/certificate/?060905_s_000 3211 04 3/12

U 11454 23 " 2 " 67 20 40 U 12399 12 " 1 2 30 3 U 12399 22 " 2 " 67 7 1/2 U 11451 03 Reversing 0 3 20 3 5 U 11451 13 " 1 " 30 7 1/2 10 U 11451 23 " 2 " 67 20 40 Starters U 11452 03 Reversing 0 3 20 3 5 U 11452 13 " 1 " 30 7 1/2 10 2 pole devices are single phase; 3 pole devices are three phase. http://www.csagroup.org/services industries/product listing/certificate/?060905_s_000 3211 04 4/12

Class 8965, reversing contactors, Type R, open type, rated 1 hp, 100 115V, 1 1/2 hp, 220 230V, single phase, 2 hp, 110 115V, 3 hp, 220 480V, 2 or 3 phase. Class 8965, 8 (two unwired, 3 pole mech. interlocked contactors), Type R, Series A or D, open type, rated 3 hp, 600V max, 3 ph. AC contactor and starter ratings include the following (maximums): Horsepower Single Phase Three Phase Starter or Contactor Size Amps (Open) 115V 230V 200V 230V 380V 575V 00 9 1/3 1 1 1/2 1 1/2 1 1/2 2 0 18 1 2 3 3 5 5 1 27 2 3 7 1/2 7 1/2 10 10 1P 30 3 5 2 45 3 7 1/2 10 15 25 25 3 90 7 1/2 15 25 30 50 50 4 135 40 50 75 100 5 270 75 100 150 200 6 540 150 200 300 400 7 750 250 300 450 600 Medium voltage contactors (ac). http://www.csagroup.org/services industries/product listing/certificate/?060905_s_000 3211 04 5/12

Class 8944, Type MVO 7, 1000/1200/1500V, 100 FLA, 800/700/560 LRA; Type MVO 8, 1000/1200/1500V, 150 FLA, 1200/1120/900 LRA; Min. P.F. 30 percent (1200V max), 45 percent (1500V max). Contactors Class 8910, open, single phase, Type DP12..S5, 115V ac, 1 hp, 230V ac, 2 hp; Type DP22..S5, 115V ac, 2 hp, 230V ac, 3 hp; Type DP32..S5, 115V ac, 2 hp, 230V ac, 5 hp. Note: Open type units are CSA Certified for use only as components of other equipment where the acceptability of the combination has been determined by CSA International. Contactors, open, Series DPA 122, DPA 123, rated as follows: Horsepower Type Phase Poles 115V 230V 460V 575V DPA122 1 2 10 25 DPA123 1 3 3 3 10 25 40 75 75 Notes: 1. Contactors and Starters, Sizes 0 to 6, Classes 8502, 8536, 8702, 8736, 8810, 8903, 2510, 2511 and 2512 may be provided with Class 9999 kits as follows: Type SX Series auxiliary contacts, rated A600. 2. These contactors are Certified as components for use only in other Certified equipment where the suitability of the combination is determined by CSA International. 3. Class 8536, 8736, 8810, 8502, 8702 devices may be provided in special purpose enclosures, CSA Types 1, 3R, 4, 4X or 12. http://www.csagroup.org/services industries/product listing/certificate/?060905_s_000 3211 04 6/12

Class 8536, Type W (with suffixes), vacuum starters, open type, Sizes 4 to 6, 400 hp max, 575V ac max, 3 ph. Electrical ratings are as follows: HP Rating Type 200V 230V 460V 575V WF03 40 50 100 100 WG03 75 100 200 200 WH03 150 200 400 400 Note: Open type devices are Certified as components for use only in other Certified equipment where the suitability of the combination has been determined by CSA International. http://www.csagroup.org/services industries/product listing/certificate/?060905_s_000 3211 04 7/12

Across the line motor controllers, enclosed, Cat Nos LE1U and LESU(non reversing) and Cat No LE2U (reversing), 60 hp max, max, 600V ac max and Cat No LE1D, 40 hp max, 600V ac max. Auxiliary contact rated A600, P600. Coils rated 24 600V ac, 50 to 60Hz. Main contact ratings are as follows: Maximum Horsepower Installed Contactor LESU and LE1U Controller 1 ph LE1U and LE2U Controller 3 ph LC1 or LC2 115V 230V 200V 230V 460V 575V D09 D09 0.5 1 2 2 5 7.5 D12 D12 1 2 3 3 7.5 10 D18 D18 1 3 5 5 10 15 D25 D25 1.5 3 5 7.5 15 20 D32 D32 2 5 7.5 10 20 25 D40 D40 3 5 10 10 30 30 D50 D50 3 7.5 10 15 30 40 D65 D65 5 10 15 20 40 50 D80 D80 5 10 20 20 50 60 http://www.csagroup.org/services industries/product listing/certificate/?060905_s_000 3211 04 8/12

Across the line motor controllers, combination starters, Cat No LE1U (non reversing) and Cat No LE2U (reversing), 60 hp max, max, 600V ac max. Auxiliary contact rated A600, P600. Coils rated 24 600V ac, 50 to 60Hz. Combination starters with instantaneous trip circuit breakers, enclosed in CSA Type 3R enclosures, Cat No 8539MESU and 8539ME1U (with suffixes), 10 hp max, 600V ac max. Auxiliary contacts rated A600, P600. Coils rated 120 600V ac, 60Hz. AC Contactor, Cat. No. 8502REQ3537G3, Size 2, non reversing, across the line, magnetically operated, open type, rated 45A (max), 3 hp, 115V and 7.5 hp, 230V, single phase, 10 hp, 200V, 15 hp, 230V, 25 hp, 380V, 25 hp, 575V, three phase. AC Starter, Cat. No. 8536REQ3537G6, Size 2, non reversing, across the line, magnetically operated, open type, rated 45A (max), 3 hp, 115V and 7.5 hp, 230V, single phase, 10 hp, 200V, 15 hp, 230V, 25 hp, 380V, 25 hp, 575V, three phase. AC Contactor, Cat. No. 8502REQ3537G8, Size 3, non reversing, across the line, magnetically operated, open type, rated 90A (max), 7.5 hp, 115V; 15 hp, 230V single phase; 25 hp, 200V; 30 hp, 230V; 50 hp, 380V; 50 hp, 575V three phase. RMS sym. AC starter, Cat. No. 8536REQ3537G4, Size 3, non reversing, across the line, magnetically operated, open type, rated 90A (max), 7.5 hp, 115V; 15 hp, 230V single phase; 25 hp, 200V; 30 hp, 230V; 50 hp, 380V; 50 hp, 575V three phase. AC starter, Cat. No. 8736REQ3537G7, Size 3, reversing, across the line, magnetically operated, open type, rated 90A (max), 7.5 hp, 115V; 15 hp, 230V single phase; 25 hp, 200V; 30 hp, 230V; 50 hp, 380V; 50 hp, 575V three phase. http://www.csagroup.org/services industries/product listing/certificate/?060905_s_000 3211 04 9/12

AC Starters: Class 8536, non reversing, open type and general purpose enclosed; Class 8736, reversing, open type; Class 8810, two speed, open type; and AC Contactors: Class 8502, non reversing, open type and general purpose enclosed; Class 8702, reversing, open type; Sizes 00, 0, 1 and 1P, across the line, magnetically operated, rated: Starter Size Current (A) Horsepower Short circuit (ka RMS sym.) Single Phase Three Phase Standard High fault* Open Enclosed 115V 230V 200V 230V 380V 575V fault* 480V 600V 00 10 9 1/3 1 1.5 1.5 1.5 2 5 100 100 0 20 18 1 2 3 3 5 5 5 100 100 1 30 27 2 3 7.5 7.5 10 10 5 100 100 1P 36 30 3 5 5 100 100 * See note 3 for application details. AC Contactors: Class 8502, open or enclosed, Type REQ 2616 G1, 3 phase, Ratings: 10 hp, 230V, 15 hp, 460V. RMS sym. 600Vac max (See note 3 for application details). AC Contactor, Cat. No. 8502REQ3537G1, Size 1, non reversing, across the line, magnetically operated, open type, rated 30A max, single phase, 2 hp, 115V and 3 hp, 230V; three phase, 7.5 hp, 200V, 7.5 hp, 230V, 10 hp, 380V, 10 hp, 575V. RMS sym. 600Vac max (See note 3 for application details). AC Starter, Cat. No. 8536REQ3537G5, Size 1, non reversing, across the line, magnetically operated, open type, rated 30A max, single phase, 2 hp, 115V and 3 hp, 230V; three phase, 7.5 hp, 200V, 7.5 hp, 230V, 10 hp, 380V, 10 hp, 575V. RMS sym. 600Vac max (See note 3 for application details). Notes: 1. Type designation are suffixed with letters and/or numbers to denote type of enclosure O for open, G for general purpose enclosed, contact arrangement, etc. 2. Open type units are CSA Certified for use only as components of other equipment where the acceptability of the combination has been determined by CSA Group. 3. Class 8502 and 8702 contactors: These devices are suitable for use on a circuit capable of delivering not more than 100,000rms symmetrical A, 600 V~ maximum, when protected by Class RK5, RK1, T or J fuses with a maximum rating of 60 A; 480 V~ maximum, when protected by a circuit breaker with a maximum rating of 70 A. For a circuit capable of delivering more than 5,000 rms symmetrical A the minimum enclosure volume is 300 cu in. The equipment enclosure must have a minimum of four fastening points or a piano hinge and two fastening points. 4. Class 8536 and Class 8736 devices of the E Series and class 8810 of A series shipped with a Tesys D class 10 or 20 overload relay, in such cases, these starters have the following characteristics: Optional high fault ratings: Maximum 65kA RMS at 480V when protected by thermal magnetic circuit breaker rated not more than shown in the table below. Maximum 100kA RMS at 600V when protected by class CC or class J fuses rated not more than shown in the table below. For a circuit capable of delivering more than 5,000 rms symmetrical A, the minimum enclosure volume is 480 cu in. and the enclosure must have a minimum of four fastening points or a piano hinge and two fastening points. Overload Relay Catalog Number Max. Circuit Breaker Ampacity Max. Class J or CC Fuse Ampacity LRD03 LRD07, LR3D03 LR3D07 15 10 http://www.csagroup.org/services industries/product listing/certificate/?060905_s_000 3211 04 10/12

LRD04L LRD07L, LR3D04L LR3D07L LRD08, LR3D08, LRD08L, LR3D08L 15 15 LRD10, LR3D10, LRD10L, LR3D10L 15 20 LRD12, LR3D12, LRD12L, LR3D12L 15 30 LRD14, LR3D14, LRD14L, LR3D14L 20 40 LRD16, LR3D16, LRD16L, LR3D16L 25 50 LRD21, LR3D21, LRD21L, LR3D21L 35 60 LRD22, LR3D22, LRD22L, LR3D22L 45 60 LRD32, LR3D32, LRD32L, LR3D32L 60 60 5. Short Circuit Ratings for Units with Tesys D Solid State Overloads: The starter is suitable for use on a circuit capable of delivering not more than 5,000 rms symmetrical A,600 V~ maximum, when protected by branch circuit overcurrent protection in accordance with the Canadian Electrical Code (CEC). The starter is also suitable for use on a circuit capable of delivering not more than 100,000 rms symmetrical Amps; at 600 V~ maximum when protected by a Class J or CC fuse rated not more than shown in the table below. The starters are also rated for the rms symmetrical short circuit current in amps shown below at 480 V~ maximum when protected by thermal magnetic circuit breakers rated not more than shown in the table below. For a circuit capable of delivering more than 5,000 rms symmetrical A, the minimum enclosure volume is 480 cu in. and the enclosure must have a minimum of four fastening points or a piano hinge and two fastening points. Overload Relay Catalog Number Max. Circuit Breaker Ampacity (A) Max SC Current rating with Circuit Breaker (A)@ Voltage (V) Max. Class J or CC Fuse Ampacity (A) for 100,000 A SC rating LR9D01 15 5,000 @ 480 1 LR9D02 15 5,000 @ 480 6 LR9D08 30 5,000 @ 480 25 LR9D32 70 65,000 @ 480 80 /ds http://www.csagroup.org/services industries/product listing/certificate/?060905_s_000 3211 04 11/12

http://www.csagroup.org/services industries/product listing/certificate/?060905_s_000 3211 04 12/12