BR230 MOTORIZED VIP. OPERATION and MAINTENANCE MANUAL

Similar documents
Operating Instructions Pedestrian Turnstile Type MPT 33

JBI Docupunch P33 Automatic Punch

Installation instructions

Operating Instructions Type MPT 53

MST FULL HEIGHT TURNSTILES TYPICAL INSTALLATION SITES COMMON APPLICATIONS DESCRIPTIVE SPECIFICATIONS ALVARADOMFG.COM

Model 2300DL Installation Guide

GLM SERIES CONTROL Users Manual Rev:

MST. Full Height Turnstiles. alvaradomfg.com

TROUBLESHOOTING TP. Index

/ S. Warhawk Road, Conifer, CO /

Model 2300JL Installation Guide

PLC Controlled High Performance Automatic Grease Lubricator

AeroVironment Universal Solar Pump Controllers

PCS 100 SYSTEM INSTALLATION INSTRUCTIONS

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

CAUTION -TABLE OF CONTENTS- II. OPERATING INSTRUCTIONS

TURNSTILES GA2-TM-(DA) CATALOGUE GASTOP PREMIUM

Turbo M Series onboard charger

Centrifuge Operator / Service Manual

Transporter Current Flow Diagram No. 671 / 1 Edition

Semi-automatic Thermal Sealer

SB106WG. LIGHTING SYSTEM (balloon type) SISTEMA DE ILUMINACIÓN (tipo de balón) ISSUE EMD-TU2343 9ZZ PRINTED IN JAPAN March 2007

(1032 mm) 30.5 (775 mm) 44 ( mm)

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

Altec LMAP. (Load Moment and Area Protection) Telescopic Boom Cranes. Calibration

Model SL-12K-A SCISSOR LIFT. wheel alignment model. (11000 LBS / 5000Kg Capacity) INSTALLATION & OPERATION INSTRUCTION (SECOND EDITION)

Surepowr Series Sure 150

Specifications. General

SR8-Plus 2 Phase Step Motor Drive

INSTRUCTION AND USE MANUAL

EDC-E. Waist HIGH Turnstiles. alvaradomfg.com

Operations and Service Manual. X30208 Load Bank

TWO-WAY LED AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide WARNING

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

Vehicle Security System

RE Generation II Troubleshooting Guide Section I Preliminary Information and Evaluation

MN-IST-SD SERIES-E. IST-SD SERIES DIGITAL TORQUE SCREWDRIVER OPERATION MANUAL

SAFETY PRECAUTIONS SAFETY FIRST!... 1 ABOUT THE CODE READER CONTROLS AND INDICATORS... 3 DISPLAY FUNCTIONS... 4

28W WORK LAMP Model: CTL28 Part No:

OPERATING INSTRUCTIONS

WINCHMAX. Hydraulic Winch Instructions b b b

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

PowerLink GW series Eddy Current Dynamometer User Manual

Vehicle Security System

PACKAGE LIST CONTENT. User Manual 1 GIMBAL STABILIZER 1 MICRO USB CABLE 1

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

1000-Watt Energy Center

Smart Battery Charger

MBM8 / MBM11- Barriers. Installer and User s manual

Go Power! Manual. GP-Smart Charger

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm)

DKG-114 MANUAL AND REMOTE START UNIT

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

STEALTH CONTROLS. For. By restomod air

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

WELDING POSITIONER OPERATION MANUAL MODEL TT-100 V1.0

REV 1 THE GRIP IDLE MANAGEMENT SYSTEM

MOVING HEAD. User manual CAUTION!

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

Installation, Operation and Maintenance Manual

MT50 & MT150 Electrical Multi-turn Valve Actuators

PH3 AIR INTAKE EMERGENCY SHUT-OFF VALVE WITH POWERGUARD SMART OVERSPEED LIMITER. Generic PH3 Truck Shut-Off Valve Kit.

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

WARNING: ALWAYS UNPLUG THE TREADMILL FROM THE ELECTRICAL OUTLET BEFORE SERVICING THE UNIT.

HORTICULTURE EQUIPMENT & SERVICES

AUTOMATIC STANDBY ACTIVATION. Operation Manual

EasySelect-Cup Manual Powder Gun

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

Defender 3000 Series Base Instruction Manual

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Torque Test Stands Series TS MODELS TST / TSTH & TSTM / TSTMH. User s Guide

91 (2311 mm) (1581mm) (1375 mm)

Mechanical Key Cutting Machine CONDOR XC-002 CONDOR. Mechanical Key Cutting Machine XC-002. User Manual

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

PANcharge1k Battery Charger User's Manual

ELECTRONIC MANUAL VOLTAGE CONTROL Model: MVC 300. Part Number:

PRODUCT MANUAL OPERATOR S MANUAL VEHICLE SPEED CONTROL SYSTEM TOYOTA SPECIAL DESIGN

materials and workmanship for 2 years. Should the centrifuge require warranty or Phone: or Fax:

Instruction Manual for the. E-SL 450 Series

Setup and Programming Manual

Operation & Maintenance Manual

Induction Power Supplies

Installation, operation and maintenance manual

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

1-50 KVA SINGLE-PHASE SERVO REGULATOR INSTRUCTIONS FOR USE SERVO SINGLE-PHASE VOLTAGE REGULATOR

X100P Load Bank. Read all instructions before using the load bank. Contents

3. Operating instructions: Minor 200

ELECTRONIC PLATFORMS. T and TE SERIES

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

ACCUVERT (tm) DISPENSING SYSTEM

Measurements are expressed in millimeters.

AUTOMATIC CONTROL ROLLING DOOR OPENER

WARNING: ALWAYS UNPLUG THE TREADMILL FROM THE ELECTRICAL OUTLET BEFORE SERVICING THE UNIT.

GCU-10. Automatic Engine Control Unit Operators Manual

Model 8000XL OPERATOR MANUAL

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Paraffin Dispenser Catalog # PD-120, PD-220 Operator s Manual Version 1.5b, Jan 2007

MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 3/2 DIRECT ACTING, UNIVERSAL TYPENUAL RESET SOLENOID VALVE MODEL M3007

Transcription:

BR230 MOTORIZED VIP OPERATION and MAINTENANCE MANUAL 1

TABLE OF CONTENTS TURNSTILE SAFETY INSTRUCTIONS 3 TURNSTILE USER INSTRUCTIONS 3 BR230 MOTORIZED VIP TURNSTILE TECHNICAL SPECIFICATIONS 4 BR230 MOTORIZED VIP TURNSTILE SYSTEM SPECIFICATIONS 5 POWER SUPPLY 5 BR230 MOTORIZED VIP TURNSTILE ASSEMBLY INSTRUCTIONS -1 6 BR230 MOTORIZED VIP TURNSTILE MATERIAL LIST 7 BR230 MOTORIZED VIP TURNSTILE ELECTRICAL CIRCUIT DIAGRAM 8 BR230 MOTORIZED VIP TURNSTILE -HOW TO RUN 9 BR230 MOTORIZED VIP TURNSTILE MAINTENANCE INSTRUCTIONS 11 BR230 TURNSTILE TROUBLESHOOTING 12 2

BEFORE YOU START Thank you for purchasing BR230 MOTORIZED VIP Turnstile. Please, carefully read the instructions contained in this manual for a long and smooth operation of the turnstile and keep the manual for future references. TURNSTILE SAFETY INSTRUCTIONS It is recommended to read all safety and maintenance instructions before installing and using the turnstile. Read the manual, before operating the turnstile. Do not open the turnstile, due to safety precautions. Any repairment must be done only by authorized services. Modifications made by user may result in danger for the turnstile and people. Do not operate damaged turnstiles and call an authorized service immediately. Comply with the power and voltage values specified in the technical specifications of turnstile. Comply with the operating temperature range specified in the technical specifications of turnstile. Check the power supply and control the card connections before reenergizing the turnstile afterwards any maintenance or damage. Use certificated spare parts and accessories approved and allowed by the producer. In any problem, cut off the electrical connections of the turnstile and call an authorized service. During the cleaning and maintenance, cut off the electrical connections. Otherwise damage to the parts may result. Use wet rag for cleaning. Keep the turnstile away from over heated or fire environment. Over heat may result in a damage to the turnstile. Do not use the turnstile in high magnetic areas. Do not expose the turnstile to excessive water in order to prevent any penetration. Provide your turnstile with electrical grounding connection. 3

TURNSTILE USER INSTRUCTIONS The turnstile is designed so as to allow one person to pass each time and more than one person mustn t try to pass at the same time. In case of not functioning properly, avoid actions that may result in damage to the turnstile. In case of any malfunctioning, in order to avoid further damage to the system, should the system be taken in idle state or mustn t be used. Substances harmful to turnstile mustn t be used for cleaning. The manufacturer will not accept any responsibility for any inquiry or damage resulting from incompliance with the security and safety instructions indicated above. BR230 MOTORIZED VIP TURNSTILE TECHNICAL SPECIFICATIONS Power : 220V 50Hz / 30 W Operating Voltage : 24 V DC +- %20 Body Features : Waterproof body with 1,5 mm 304 grade stainless steel System : It is commanded by Dry Contact or any other recommended voltage. It is possible to use with all kinds of access control units or token mechanisms. Additionally, it can be commanded by RS232 and RS485 (optional). Pass Block : By using 15 mm transparent plexiglass with separator. Locking :It is locked by 24DC solenoid with special magnetic gear mechanism, locks when the solenoids are pulled. In emergency, the system is shut down and turnstiles provide free passing in both directions. Motion :Bidirectional entry/exit, free control Arms :15 mm, and made up of plexiglass. Operating Temp : - 10 C 0 - + 50 C 0 Passing Signs :Red light while the plexiglass is closed and green light while it is open (optional). Dimensions :230 x 1030 x 990 mm Weight :35 kg Accessories :Electrical control unit, Remote unit, Button unit, Modular Platform 4

BR230 MOTORIZED VIP TURNSTILE SYSTEM SPECIFICATIONS 1. The system is designed to allow free pass. When the power is turned off, the arm turns freely. 2. The parts of the turnstile carrying load and giving motion are made up of stainless steel or galvanized materials. 3. The pass is performed in a silent and smooth manner with the aid of electronic gear and smart control unit. 4. Every turnstile is designed with a control card, however, it can be modified and programmed for customer needs and wants (optional). 5. Turnstiles switch to home mode in 15 sec if there is no pass after the entry data is received (the locking time can be calibrated if needed as optional). 6. The turnstile is switched to the emergency mode by the manual button or any data coming from the fire alarm system. In emergency, the system is shut down and turnstiles provide free passing in both directions. 7. Turnstiles allow only one pass based on the Access type (token, card reader, button, etc.). 8. Entry data is transferred to terminal after the necessary system infrastructure. POWER SUPPLY 1. Do not remove the protecting seal on the power supply. 2. Please perform your operations paying attention to the warnings, electricity and safety fuse data on the protecting seal and power supply. 3. On the label placed on the power supply, the connection points are shown. Please follow the signs on the label while carrying out the connection. NOTE: PLEASE DO NOT PROVIDE THE POWER FROM THE CARD OR POWER SUPPLY ON THE TURNSTILE TO THE EXTERNAL EQUIPMENT. THE MANUFACTURER WILL NOT ACCEPT ANY RESPONSIBILITY FOR ANY INQUIRY OR DAMAGE RESULTING FROM INCOMPLIANCE WITH THE SECURITY AND SAFETY INSTRUCTIONS INDICATED ABOVE. 5

BR230 MOTORIZED VIP TURNSTILE ASSEMBLY INSTRUCTIONS 1. Select a proper location so as not to obstruct turnstile s operation. 2. Check the structure of the ground of installation site to ensure the necessary stability requirements. 3. Mark the hole places on the ground in which the turnstile will be mounted. 4. Drill the marked mounting holes by Ø10 drill bit and clean the dust inside the hole by the help of the air. 5. Fix the steel anchors to the drilled holes. If the ground is not strong, fix the steel anchors after using chemical soil mixture. (Wait 20 minutes for hardening of chemical soil mixture) 6. Pass the power and data cables which are prepared before through the hole on mounting plate. 7. Put the mounting plate on the steel anchors and after putting the washer and nuts, fix the ground. 8. You can see the pictures and drawing illustrating anchor and turnstile s mounting operation. 6

HOLE FOR CABLES ANCHOR BR230 MATERIAL LIST A B C D E M8x25 M8 M8 INBUS RONDELA NUT BOLT M6x10 STEEL ANCHOR M8 WASHER 4 pieces 4 pieces 4 pieces 4 pieces 4 pieces 7

BR230 MOTORIZED VIP TURNSTILE ELECTRICAL CIRCUIT DIAGRAM If you want it not to open anti clockwise, the wire connected to GEMO AUX SUPPLY OUT +18 V is connected to GEMO 12 (INHIBIT CW) entry. If you want it not to open clockwise, the wire connected to GEMO AUX SUPPLY OUT +18 V is connected to GEMO 121 (INHIBIT Microswitch layout brown pink grey white green yellow D I S P L A Y red-led green-led black red red blue brown Power supply black red brown red yellow green white yellow green white grey pink brown 8

BR230 MOTORIZED VIP TURNSTILE -HOW TO RUN [A] THE CONTROL IS STARTED IN 3 SEC AFTER POWER CUT. IF THE ARM IS IN ZERO MODE (CLOSED MODE), IT IS LOCKED AT THIS POSITION. IF THE ARM IS BETWEEN OPEN & CLOSED POSITION, IT MOVES IN CCW DIRECTION. IF THE ARM COMES TO THE CLOSED MODE, IT STOPS & LOCKS. IF THE ARM IS OPEN IN CCW DIRECTION, IT STOPS AND CLOSES AFTER 5 SEC. NOTE: IF IT IS INHIBITED IN CCW DIRECTION IN SETUP, ZERO MODE DIRECTION IS CW. [B] THE BUTTONS ON THE REMOTE CONTROL; 1) CCW (COUNTER CLOCKWISE) BUTTON: IT IS FOR MOVING THE ARM IN ANTI CLOCKWISE DIRECTION. IF THE ARM IS CLOSED, IT OPENS IN CCW DIRECTION. IF CW IS OPEN, THE ARM IS CLOSED. 2) CW (CLOCKWISE) BUTTON: IT IS FOR MOVING THE ARM IN CLOCKWISE DIRECTION. IF THE ARM IS CLOSED, IT OPENS IN CW DIRECTION. IF CCW IS OPEN, THE ARM IS CLOSED. NOTE: IF THE BUTTON IS PRESSED DURING OR AFTER THE ARM IS OPENED, THE ARM REMAINS OPEN. IN ORDER TO CLOSE THE ARM, PRESS THE OTHER BUTTON. IF THE ARM IS OPEN AND NOT IN IDLE MODE, IT IS CLOSED AFTER 5 SEC (TIME CAN BE CALIBRATED IN SETUP). 3) IDLE/CONTROLLED BUTTON: WHEN PRESSED, THE ARM IS IDLE AND IT CAN BE MOVED BY HAND. WHEN THE BUTTON IS IN NORMAL POSITION, THE EQUIPMENT IS CONTROLLABLE. [C] USING SENSOR WHILE OPENING; IF THE SENSOR DETECTS A PERSON, THE ARM IS OPENED AFTER PRESSING THE OPEN ARM BUTTON. [D] RED: READY / GREEN: ON WARNING LIGHT; AS OPENING GREEN BLINKS, WHEN OPENED GREEN IS ON. AS THE ARM IS CLOSING RED BLINKS, WHEN CLOSED RED IS ON. 9

Closed Open in CW Opening in CCW direction Closing in CCW direction Open in CCW direction Closed Closing Closed 10

BR230 MOTORIZED VIP TURNSTILE MAINTENANCE INSTRUCTIONS 1. The clothing of the turnstile must be cleaned with wet rag. 2. The connection screws of turnstile should be visually checked every 6. 3. Turnstile arm connection must be visually checked. NOTE: Turnstile must have maintenance service by authorized service or distributors periodically. In case it is not able to contact with an authorized service or dealer, get into contact with producer firm and obtain information on periodical maintenance. BR250 Electro mechanic Turnstile Time Operation General Turnstile Plexi Bolts 12 Ground Fixing Bolts 12 Turnstile Mechanism Solenoids 12 Wheel 12 Carrier Shaft Nut 12 Gear Connection Bolts 12 Microswitches 12 Carrying mechanism 12 Electronic Card Electrical Connections 12 Motor Connection Cables 12 PLC 12 + Cleaning + Cleaning + Lubrication 11

BR230 TURNSTILE TROUBLESHOOTING Fault Reason(s) Solution(s) Although the electricity is on, the arms cannot be locked, the displays are turned off, and the turnstile is functionless. After one pass, the turnstile is not locked and it allows multiple passes. Although the electricity is on the arms are turning freely. The turnstile does not send info after pass. Turnstile arms are giving noise due to friction while turning. The entry and exit speeds are different. The turnstile is not standing at 90 degrees, and it is exceeding the level. 1. Power supply may be off or broken. 2. Electrical fuse could be blown out. 1. Direction sensor microswitches could be broken. 2. Electronic card could be broken. 3. Magnetic gear could be broken. 1. Solenoid could be broken or there may be connection defects. 2. Electronic card could be broken. 1. Cycle sensor micro switches could be broken or there may be connection defects. 2. There may be defects in the cable transferring data. 3. Electronic card could be broken. The main mechanism may have been hit and/or the nut could be loosened up. The turnstile may not be mounted in a level ground. Switch positions may be tilted due to hit or switches could be broken due to hits. 1. Check whether the electrical cable is plugged in. 2. Change power supply if needed. 1. Replace microswitches. 2. Replace electronic card. 3. Check the magnetic gear connections and replace if broken. 1. Replace solenoid and also check the connections. 2. Replace electronic card. 1. Replace microswitches and check the connections. 2. Check the cables carrying data. 3. Replace electronic card. Tighten the nut. If that is not the case, replace the entire mechanism. The turnstile should be mounted on a level ground and this operation should be checked by water balance. 1. Calibrate the switch positions. 2. Replace the switches. 12

B a r k o d e s B i l g i s a y a r S i s t e m l e r i B i l g i l e t i ı i m V e Y a z ı l ı m T i c. L t d. t i. A l t a y Ç e ı m e M a h a l l e s i S a n a y i S o k a k N o : 8 D e m i r l i S i t e s i B B l- o sk t am na bl ut l e / p Te u r k e y T e l : + 9 0 ( 2 1 6 ) 4 4 2 2 0 k6 s: 2 + F9a 0 ( 2 1 6 ) 4 5 9 0 4 8 4 W e b : w w w. b a r k o d e s. c o m. t r m a i l : i n f o @ b a r k o d e s. c o m. r t 13