Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Similar documents
Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Parts and characteristics

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

CAV controllers Type RN

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Type VSD35. Nominal length up to 1500 mm: one spigot

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN.

CONSTANTFLOW Volume Flow Controllers

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Ceiling swirl diffusers with perforated face plate

VARYCONTROL VAV Dual Duct Terminal Boxes

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Slot diffusers for ceiling installation

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION

Volume Flow Limiters Type VFL

Ceiling swirl diffusers

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

VAV Terminal Units SDS

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Ceiling swirl diffusers

Ceiling swirl diffusers with perforated face plate

For installation into ductwork

Technical documentation

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Multileaf damper with actuator

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Pressure relief dampers

VAV terminal units VARYCONTROL. Installation and commissioning manual. GB/en. LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Ventilation grilles for installation into walls, sills or rectangular

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Ventilation grilles for installation into walls, sills or rectangular

Fan - Powered Terminal Unit Series Flow

VAV TERMINAL BOXES TYPE: BA BT

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Home > Products > Filter elements and filter units > Particulate filter air terminal devices > Pharmaceutical clean room terminal filters > Type TFP

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

Ceiling swirl diffusers

Mechanical mixing box MBM

Air distribution product

TYPE EK-EU SMOKE CONTROL DAMPER

Variable Air Volume Dampers

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

Technical information

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

Ducted HEPA filter units for highly sensitive areas

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Technical Brochure. LTG Air Distribution. Variable flow rate controllers VRFactive. Rectangular, with LTG map control.

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

Air Displacement Vent Units

VAV controller. TROX Auranor Norge AS. Telephone Fax

... TROX UK LABCONTROL Facility

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

Transcription:

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Circular VAV terminal units for standard applications regarding the supply air or extract air control in variable air volume systems Suitable for the control of volume flow rate, room pressure or duct pressure Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL) High control accuracy even with upstream bend (R = 1D) Suitable for airflow velocities up to 13 m/s Closed blade air leakage to EN 1751, up to class 4 Casing air leakage to EN 1751, class C Optional equipment and accessories Acoustic cladding for the reduction of case-radiated noise Secondary silencer Type CA, CS or CF for the reduction of air-regenerated noise Hot water heat exchanger Type WL and electric air heater Type EL for reheating the airflow

Application Circular VARYCONTROL VAV terminal units of Type TVR for the precise supply air or extract air flow control in variable air volume systems Closed-loop volume flow control using an external power supply For controlling, restricting, or shutting off the airflow in air conditioning systems Shut-off by means of switching (equipment supplied by others) Special characteristics Integral differential pressure sensor with 3 mm measuring holes (resistant to dust and pollution) Factory set-up or programming and aerodynamic function testing Volume flow rate can be measured and subsequently adjusted on site; additional adjustment tool may be necessary Nominal sizes 100, 125, 160, 200, 250, 315, 400 Variants TVR: VAV terminal unit TVR-D: VAV terminal unit with acoustic cladding TVR-FL: VAV terminal unit with flanges on both ends TVR-D-FL: VAV terminal unit with acoustic cladding and flanges on both ends Units with acoustic cladding and/or a secondary silencer Type CA, CS or CF for demanding acoustic requirements Acoustic cladding cannot be retrofitted Construction Galvanised sheet steel P1: Powder-coated, silver grey (RAL 7001) A2: Stainless steel Parts and characteristics Ready-to-commission unit which consists of mechanical parts and control components. Averaging differential pressure sensor for volume flow rate measurement Damper blade Factory-assembled control components complete with wiring and tubing Aerodynamic function testing on a special test rig prior to shipping of each unit Set-up data is given on a label or volume flow rate scale affixed to the unit High control accuracy (even with upstream bend R = 1D) Attachments Easy controller: Compact unit consisting of controller with potentiometers,

differential pressure transducer and actuator Compact controller: Compact unit consisting of controller, differential pressure transducer and actuator Universal controller: Controller, differential pressure transducer and actuators for special applications LABCONTROL: Control components for air management systems Accessories G2: Matching flanges for both ends D2: Lip seals on both ends (factory fitted) Useful additions Secondary silencer Type CA, CS or CF for demanding acoustic requirements Heat exchanger Type WL Electric air heater Type EL Construction features Circular casing Spigot suitable for circular ducts to EN 1506 or EN 13180 Spigot with groove for lip seal Position of the damper blade indicated externally at shaft extension TVR-FL: Flanges to EN 12220 Materials and surfaces Galvanised sheet steel construction Casing and damper blade made of galvanised sheet steel Damper blade seal made of TPE plastic Aluminium sensor tubes Plastic bearings Powder-coated construction (P1) Casing made of galvanised sheet steel, powder-coated Damper blade and shaft made of stainless steel 1.4301 Sensor tubes made of aluminium, powder-coated Stainless steel construction (A2) Casing, damper blade and shaft made of stainless steel 1.4301 Sensor tubes made of aluminium, powder-coated Variant with acoustic cladding (-D) Acoustic cladding made of galvanised sheet steel Rubber profile for the insulation of structure-borne noise Lining is mineral wool

Mineral wool To EN 13501, fire rating class A1, non-combustible RAL quality mark RAL-GZ 388 Biosoluble and hence hygienically safe according to the German TRGS 905 (Technical Rules for Hazardous Substances) and EU directive 97/69/EG Standards and guidelines Hygiene conforms to VDI 6022 Closed blade air leakage to EN 1751, class 4 (nominal size 100, class 2; nominal sizes 125 and 160, class 3) Nominal sizes 100, 125, and 160 meet the general requirements, nominal sizes 200 400 meet the increased requirements of DIN 1946, part 4, with regard to the acceptable closed blade air leakage Casing air leakage to EN 1751, class C Maintenance Maintenance-free as construction and materials are not subject to wear TECHNISCHE INFORMATION Function, Technical data, Quick sizing, Specification text, Order code, Related Products Variants, Attachments, Dimensions and weight Installation details, Basic information and nomenclature

TROX Italia Online-Services Service-Hotlines TROX Academy Your contact partner Telefono +39 02-98 29 74.1 Telefax +39 02-98 29 74 60 Online fault report Società unipersonale soggetta a direzione e coordinamento di TROX GmbH Sede legale: Via Mecenate 90-20138 Milano Cap. Soc. EUR 2.000.000 R.E.A. n. 659693 Reg. Impr. MI, C.F. e P.IVA IT 00897380150 Casella di posta certificata: trox@pec.it