Vibration studies and on-site balancing of GT-1 assembly

Similar documents
Gearbox Misalignment on Combustion Gas Turbine Generator

TURBOGENERATOR DYNAMIC ANALYSIS TO IDENTIFY CRITICAL SPEED AND VIBRATION SEVERITY

Vibration Report. : Greater Noida. Date of Visit : 9 th & 10 th March 2016 OUR CONTACT: REPORT PREPARED BY. Mr. Udit Sharma

Effects of shaft geometric unconformities on the rotor-dynamic behavior in hard coupled equipment

Large Air Cooled Generator Failure

Effect Of Bearing Faults On Dynamic Behavior And Electric Power Consumption Of Pumps

ELIMINATION OF REPETITIVE THRUST BEARING FAILURES ON A PROCESS AIR COMPRESSOR

Centro América Application of EMI Diagnostics to Diesel Generators

VACUUM PUMP-3A. Running Hour: 8646 Ref Speed: 660 RPM OBSERVATION. Peakvue reading was 0.3 at Vacuum Pump NDE bearing.

Resolving Vibration Issues of Diesel Engine Driven Fire Water Pumps in QP Offshore

ELECTROMECHANICAL OPTIMIZATION AGAINST TORSIONAL VIBRATIONS IN O&G ELECTRIFIED TRAINS MICHELE GUIDI [GE O&G] ALESSANDRO PESCIONI [GE O&G]

Artesis MCM Case Studies. March 2011

ISCORMA-3, Cleveland, Ohio, September 2005

Vibration Measurement and Noise Control in Planetary Gear Train

CRITICAL SPEED ANALYSIS FOR DUAL ROTOR SYSTEM USING FINITE ELEMENT METHOD

Extremely High Load Capacity Tapered Roller Bearings

Grid Stability Analysis for High Penetration Solar Photovoltaics

Compressor Noise Control

Condition Monitoring of Electrical Machines ABB MACHsense Solution

Generator Test Report

GT-Suite Users Conference

Fuse: On-wing engine inspection

IMPROVING BOILER COMBUSTION USING COMPUTATIONAL FLUID DYNAMICS MODELLING

Vibration Signature Analysis as a Diagnostic Tool for Condition Assessment of Rotating Equipments Experience at TAPS

Improvements for Ver November 23, 2017

CASE STUDY ON RESOLVING OIL WHIRL ISSUES ON GAS COMPRESSOR

Balancing and over-speed testing of flexible rotors

IDENTIFICATION OF ABNORMAL ROTOR DYNAMIC STIFFNESS USING MEASURED VIBRATION INFORMATION AND ANALYTICAL MODELING

VIBETEC INC. 394 Collinge Rd. Hinton, AB T7V 1L1 Phone (780) Fax. (780) st Jan 2004.

Steam Turbine Seal Rub

Pump Coupling & Motor bearing damage detection using Condition Monitoring at DTPS

Job Sheet 2 Aerodynamics Power Control

ANTI-BACKLASH GEAR TRAIN INVESTIGATION. Zengxin Gao, Jani Tähtinen

TIGER Diagnostic Report

TIGER Diagnostic Report

Design and Test of Transonic Compressor Rotor with Tandem Cascade

IMPACT OF WIRELESS LASER BASED SHAFT ALIGNMENT ON VIBRATION AND STG COUPLING FAILURE. Ned M. Endres, Senior MDS Specialist

Robustness Analysis in Vehicle Ride Comfort

CHAPTER 6 MECHANICAL SHOCK TESTS ON DIP-PCB ASSEMBLY

A Grinding Solution. By John Donkers

Subsynchronous Shaft Vibration in an Integrally Geared Expander-Compressor due to Vortex Flow in an Expander

Analysis and control of vehicle steering wheel angular vibrations

Load Analysis and Multi Body Dynamics Analysis of Connecting Rod in Single Cylinder 4 Stroke Engine

2 Pole 1222MVA Turbo-Generator & 4 Pole 1690MVA Turbo-Generator

Proceedings of the World Congress on Engineering 2008 Vol II WCE 2008, July 2-4, 2008, London, U.K.

Global VPI Insulated Indirectly Hydrogen-Cooled Turbine Generator for Single-Shaft Type Combined Cycle Power Generation Facilities

KD LV Motor Protection Relay

Balancing of aeroderivative turbine

Root Cause Analysis of a vibration problem in a propylene turbo compressor. Pieter van Beek, Jan Smeulers

Reducing vibration by balancing rotor blades REPRINT. Erneuerbare Energien 08/2009. Dr. Edwin Becker & Johann Lösl, PRÜFTECHNIK Condition Monitoring

Appendix B. Chapter 11. by Resonance

11 Problems 11 Solutions Case Histories of 11 Machinery Vibration Problems Part 1

White Paper. Stator Coupling Model Analysis By Johan Ihsan Mahmood Motion Control Products Division, Avago Technologies. Abstract. 1.

BY: Paul Behnke ITT Industries, Industrial Process. Juan Gamarra Mechanical Solutions, Inc.

MAIN SHAFT SUPPORT FOR WIND TURBINE WITH A FIXED AND FLOATING BEARING CONFIGURATION

Detection of Fault in Gear Box System using Vibration Analysis Method

Drivetrain Simulation and Load Determination using SIMPACK

Condition Monitoring in the Wind Industry, Relevant Technologies, and its Importance.

Tilting Pad Journal Bearings

Electromagnetic Fully Flexible Valve Actuator

Balancing with the presence of a rub

Automotive manufacturing accelerometer applications

ROTATING MACHINERY DYNAMICS

Trouble Shooting in Vertical Fire Hydrant Pump by Vibration Analysis - A Case Study

Expand your vibration program to new heights.

Research on vibration reduction of multiple parallel gear shafts with ISFD

11 Problems 11 Solutions Case Histories of 11 Machinery Vibration Problems Part 2

RNRG WHITE PAPER Early Detection of High Speed Bearing Failures

APPENDIX A GENERAL PURPOSE STEAM TURBINE DATA SHEETS

Application examples in a wind turbine

Automotive manufacturing accelerometer applications

CONJUGATE HEAT TRANSFER ANALYSIS OF HELICAL COIL HEAT EXCHANGE USING CFD

An Investigation into a new method to repair motor cores and improve Efficiency

FLYWHEEL POWER GENERATION AND MULTIPLICATION

TWO PLANE BALANCING OF A CONICAL ROTOR DRIVEN BY VERTICAL BELT SYSTEM DESIGNED TO REDUCE GYRO EFFECT

APPLICATION OF STAR-CCM+ TO TURBOCHARGER MODELING AT BORGWARNER TURBO SYSTEMS

COMPANDER VIBRATION TROUBLESHOOTING. Sébastien Jaouen, Cryostar Cliff Bauer, MOL Stéphane Berger, Flender Alain Guéraud, Cryostar

/ Marley Ultra Low-Noise Fan / User Manual

October - December JCPS Volume 9 Issue 4

PLACE FOR TITLE AUTHORS. Potassium Carbonate Pump Failure High Axial Movement due to Uncontrolled (unbalanced) forces.

Differential Expansion Measurements on Large Steam Turbines

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Reducing vibration by balancing rotor blades REPRINT. Erneuerbare Energien 08/2009. Dr. Edwin Becker & Johann Lösl, PRÜFTECHNIK Condition Monitoring

Rotas Mobile: Vehicle noise measurements. Optimizing test stand to vehicle correlation

Based on the findings, a preventive maintenance strategy can be prepared for the equipment in order to increase reliability and reduce costs.

A Comparison of the Effectiveness of Elastomeric Tuned Mass Dampers and Particle Dampers

TM1018. Geared Systems THEORY OF MACHINES. A set of products for dynamic and static experiments on geared and other drive systems

Technical Report Lotus Elan Rear Suspension The Effect of Halfshaft Rubber Couplings. T. L. Duell. Prepared for The Elan Factory.

Engine Performance Analysis

Operating Conditions that shorten Gas Engine Oil Life NNAMDI J. ACHEBE CLS, OMA I, MLT II, MLA III

Below, you can see the warning symbols used throughout the manual and their meaning.

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Rosa Power Supply Company Limited (RPSCL) Rosa Unit-2 AVR Sensitivity

Theory of Machines II EngM323 Laboratory User's manual Version I

Clutch Damper High Cycle Fatigue

Dynamic Study of Bonaire Island Power System: Model Validation and Project Experience

Equipment Maintenance: Impact on Efficiency. Matt Killen, LACAP, Baton Rouge, LA

PERFORMANCE AND EMISSION ANALYSIS OF DIESEL ENGINE BY INJECTING DIETHYL ETHER WITH AND WITHOUT EGR USING DPF

PNEUMATIC HIGH SPEED SPINDLE WITH AIR BEARINGS

Turbostroje 2015 Návrh spojení vysokotlaké a nízkotlaké turbíny. Turbomachinery 2015, Design of HP and LP turbine connection

Transcription:

Page 1 of 32 Fig-1 showing the bump test measurements made on exciter rear end. A predominant frequency at 220 Hz was seen in the spectrum

Page 2 of 32 Fig-2 showing bump test measurements made on generator NDE fan blade showing predominant frequencies at 338 Hz and 414 Hz which are quite far away from operating speeds

Page 3 of 32 Fig-3 showing bump test measurements made on generator NDE fan showing predominant frequencies at 414 Hz which are quite far away from operating speeds

Page 4 of 32 The above snap showing the existing balancing correction mass provided initially by the manufacturer on the generator rear fan assembly

Page 5 of 32 Picture-1 Picture-2 Picture-1 and 2 shows the mass correction provided on the exciter rear end. This might have been added on the exciter assembly during static balancing (slow speed balancing) at shop conditions.

Page 6 of 32 The above snaps showing dial gauge being used on the low speed coupling to check the run outs and was found to be within limits. The above snap showing physical inspection of the outer surface of the low speed coupling which was carried out at site conditions

Page 7 of 32 The above snaps showing oil inlets for low speed side gear coupling. It showed that on the left hand side of the gear coupling the oil supply was limited since there is no separate oil nozzle to supply oil to the meshing teeth, while on the right hand side the oil supply was adequate to the meshing teeth.

Page 8 of 32 Table-1 showing overall vibration levels recorded on GT-1 train before and after balancing at no load Location Horizontal Vertical Axial Before After Before After Before After Turbine front 1.83 1.35 3.16 2.97 1.21 1.02 Turbine rear 4.33 3.77 3.49 3.35 2.56 2.08 Generator front 2.66 1.63 3.02 1.51 3.91 2.19 Generator rear 6.17 4.00 4.11 2.96 1.80 1.18 Table-2 showing vibration levels recorded on gearbox input and output bearing after balancing Location Horizontal Vertical Axial Gearbox input 7.81 5.28 3.22 Gearbox output 6.22 6.44 1.76 Table-3 showing vibration levels recorded on Generator front and Generator Rear bearing after balancing and the set loaded to 12 MW Location Horizontal Vertical Axial Gearbox input 3.89 1.47 2.62 Gearbox output 5.84 5.00 1.87 Comparative casing vibration levels of Turbine front before and after balancing Vibration levels in mm/sec RMS 3.5 3 2.5 2 1.5 1 0.5 0 Before balancing After balancing Horizontal Vertical Axial Direction of measurement

Page 9 of 32 Comparative casing vibration levels of Turbine rear before and after balancing Vibration levels in mm/sec RMS 5 4 3 2 1 0 Before balancing After balancing Horizontal Vertical Axial Direction of measurement Vibration levels in mm/sec RMS 5 4 3 2 1 0 Comparative casing vibration levels of Generator front before and after balancing Before balancing After balancing Horizontal Vertical Axial Direction of measurement Vibration levels in mm/sec RMS 7 6 5 4 3 2 1 0 Comparative casing vibration levels of Generator rear before and after balancing Before balancing After balancing Horizontal Vertical Axial Direction of measurement

Page 10 of 32 Horizontal Vertical Axial Fig-4 showing comparative frequency spectrum of turbine front in HVA direction after balancing, all vibrations are in mm/sec RMS

Page 11 of 32 Horizontal Vertical Axial Fig-5 showing comparative time plots of turbine front in HVA direction, all vibrations is in mm/sec RMS

Page 12 of 32 Horizontal Vertical Axial Fig-6 showing comparative frequency spectrum of turbine rear in HVA direction, all vibrations are in mm/sec RMS

Page 13 of 32 Horizontal Vertical Axial Fig-7 showing comparative frequency spectrum of gearbox input in HVA direction, all vibrations are in mm/sec RMS

Page 14 of 32 Horizontal Vertical Axial Fig-8 showing comparative frequency spectrum of gearbox output in HVA direction, all vibrations is in mm/sec RMS

Page 15 of 32 Before Balancing After Balancing Fig-9 showing comparative frequency spectrum of generator front in horizontal direction before and after balancing, all vibrations are in mm/sec RMS

Page 16 of 32 After Balancing Before Balancing Fig-10 showing comparative frequency spectrum of generator front in vertical direction before and after balancing, all vibrations are in mm/sec RMS

Page 17 of 32 After Balancing Before Balancing Fig-11 showing comparative frequency spectrum of generator front in axial direction before and after balancing, all vibrations are in mm/sec RMS

Page 18 of 32 After Balancing Before Balancing Fig-12 showing comparative frequency spectrum of generator rear in horizontal direction before and after balancing, all vibrations are in mm/sec RMS

Page 19 of 32 After Balancing Before Balancing Fig-13 showing comparative frequency spectrum of generator rear in vertical direction before and after balancing, all vibrations are in mm/sec RMS

Page 20 of 32 After Balancing Before Balancing Fig-14 showing comparative frequency spectrum of generator rear in axial direction before and after balancing, all vibrations are in mm/sec RMS

Page 21 of 32 Horizontal Vertical Axial Fig-15 showing comparative frequency spectrum of generator front bearing in HVA directions after balancing and at 12 MW load

Page 22 of 32 Horizontal Vertical Axial Fig-16 showing comparative frequency spectrum of generator rear bearing in HVA directions after balancing and at 12 MW load

Page 23 of 32 On-site balancing protocol: The above snap showing the correction mass of 154 gm was added at 55 deg on the Generator front in the direction of rotating from the reflecting sticker which is being the 0 deg reference. It was ensured that all the allen bolts with split mass was tightened with metal lock. 1. A 2-plane balancing was attempted on the generator assembly by taking generator front as plane-1 and generator rear as plane-2 2. Based on the correction mass as shown by the balancing software a correction mass of 550 gm at 355 deg was added on generator front fan assembly and 300 gm at 55 deg on generator rear fan assembly 3. The train was rolled to FSNL, but there was increase in vibrations on generator front. 4. Hence a calculated mass of 154 gm was added on generator front at 55 deg while the above masses were removed 5. With 154 gm there was a considerable decrease in vibration levels on both generator front and rear in HVA directions and hence this mass was retained on the assembly

Page 24 of 32 Comparison of panel vibration readings with DI 440 FFT analyser The above snap showing the vibration junction box from where the vibration readings were recorded. The settings of DI 440 were made as per the parameters shown on the panel box Frequency band width: 2-2000 Hz Sensitivity: 200 mv/unit Measuring parameter: Peak Table-4 showing comparative vibration levels recorded directly from the vibration panel and also from DI 440 FFT vibration analyzer, GT-1 at FSNL Turbine front Turbine rear Gen front Gen rear All vibrations are in inch/sec (ips), pk Panel 0.21 0.08 0.22 0.26 DI 440 0.166 0.067 0.21 0.184 All vibrations are in mm/sec, pk Panel 5.7 2.2 5.7 6.8 DI 440 4.16 1.59 5.32 4.62 All vibrations are in mm/sec, RMS DI 440 3.03 1.12 3.94 3.21

Page 25 of 32 Comparative vibration levels recorded from the vibration panel and DI 440 FFT analyser Vibration levels in mm/sec Peak 8 6 4 2 0 Panel DI 440 Turbine front Turbine rear Gen front Gen rear Bearing locations Comparative vibration levels recorded from the vibration panel and DI 440 FFT analyser Vibration levels in inch/sec Peak 0.3 0.25 0.2 0.15 0.1 0.05 0 Panel DI 440 Turbine front Turbine rear Gen front Gen rear Bearing locations

Page 26 of 32 Fig-16 showing frequency spectrum recorded from the vibration junction box of GT-1 at FSNL, top: Turbine front, bottom: Turbine rear, the red circled peak is at a frequency of 30 Hz (1800 rpm).

Page 27 of 32 Fig-17 showing frequency spectrum recorded from the vibration junction box of GT-1 at FSNL, top: Gen front, bottom: Gen rear, the red circled peak is at a frequency of 15 Hz (900 rpm). Also this 15 Hz frequency was not seen on the Gen rear data.

Page 28 of 32 High temperatures in the Gen front and Gen rear bearing assembly area The above snap showing the poor ventilation and it is suspected that the hot air may have a churning action heating the generator front bearing as well as the vibration probe assembly It is recommended to have a better cooling system for the generator rear bearing assembly area as here also the hot air is being circulated during full speed which may be over heating the vibration probe. Needs to be studied.

Page 29 of 32 Observations and Conclusive Remarks: 1. The vibration levels recorded from the vibration panel was high as compared to the data recorded using DI 440 FFT vibration analyzer. 2. All the vibration probes mounted on the train needs calibration 3. Inspection and replacement of electronic vibration panels if required 4. All the couplings can be changed to diaphragm flexible couplings for better reliability and maintenance free operation 5. For the time being it is recommended to check the physical condition of the gear coupling for any dust accumulation or muck formation or deposits 6. Based on the trend data from the panel 960 rpm is the generator critical speed, 2000 rpm is the turbine rotor critical speed 7. The mass addition effected on the generator front fan assembly for the purpose of unbalance correction should not be altered in any manner. Doing so would alter the balance quality achieved. 8. Any change / alteration in the rotating mass of the generator front fan assembly will change the balance quality achieved. 9. The temperatures at generator front and rear are very high and due to this the vibration probe is misbehaving. Proper exhaust facility is to be provided for hot air coming out of generator. It is recommended to design a chimney or exhaust fan, or copy the cooling system of the GT-2. 10.It is recommended to inspect the thermal insulation of the gas turbine exhaust. 11.It is preferable to have new vibration probes which can withstand at least 150 to 200 deg temperatures. 12.A portable handheld vibration meter is recommended to take frequent measurements. Model will be selected and recommended shortly to BAFA. 13.It was observed that there is no any mechanical issues as such for the generator front or rear vibrations to reach 25 or 27 mm/sec as the vibration data from DI 440 were recorded at this location several times which showed no higher vibrations 14.If the spikes still exist before replacing the probes, for the time being it is advisable to disconnect generator bearing probes and take periodic measurements with handheld equipment till the system gets established to avoid unwanted trips. 15.As such with these defects, the machine cannot run with unpredictable trips due to high temperature. 16. The spectrums recorded from the vibration panel box from turbine front and rear showed 1800 rpm (30 Hz) and from generator front showed 900 rpm (15 Hz) frequency components. Mostly likely it is attributed for temperatures or probe fixing related issues. However, if the critical speeds of the respective machines happen to be these components, it will appear if there may be rotating looseness.

Page 30 of 32 17. After taking care of all other corrections, if still this appears, it is advisable to check the health of rotating components and their fitment. For such investigations, detailed rotor dynamic calculations will help. 18. Several failures were recorded earlier at other gas turbine sites. Failures were seen on first two stage blades because of location problems like sea coast. 19. Hence to reduce the extensive damage it is better to install probes near to the tip of the blade to monitor blade crack growth so that the equipment can be stopped and the damaged blade can be replaced to avoid further secondary damages. 20. Whenever there is an opportunity it is advisable to carry out natural frequency tests on all blades to prepare a document and check the structural integrity 21. It is advisable to take each component and prepare manufacturing drawings of all important components like bearings, couplings etc. 22. A few balance masses that can be fit into the fan slot of generator front and rear assembly are to be made ready for any field balancing activity in future. 23. It can be in the range of 20, 30, 40, 50 and 60 gm. >>>>BAFA<<<<