Installation and Maintenance Manual. Medical Gas Outlet. British Standard Slim Style Compatible

Similar documents
Installation and Maintenance Manual. Medical Gas Outlet. British Standard Compatible

PRECISION UK Ltd. Medical Gas Outlet BS Standard

Outlets and Accessories

Axis MEDICAL GAS TERMINAL UNITS

Axis AGSS TERMINAL UNITS

FLEXIBLE PENDANTS with Axis MEDICAL GAS TERMINAL UNITS

Service Manual Gemini, Diamond II and Diamond III Medical Gas Outlets for Concealed Piping and Console Applications

RIGID PENDANT. Phoenix Pipeline Products Limited. Installation, Operation and Maintenance Manual

Gemini, Diamond II and Diamond III Medical Gas Outlets for Concealed Piping and Console Applications

Technical Datasheet. SP Terminal Units. Classification. Services. Terminal Block. Check Valve Assembly. Tailpipe Options

At Amico Labs we are dedicated to continued growth while producing products of outstanding quality, and providing excellent service.

PRECISION UK Ltd DUPLEX AGSS PLANT

Pressure Switch with Gauge for Pressure

CEGA FORANO BY GREGGERSEN

Condor Manual. Corporation

Technical Specification

RETRACTABLE CEILING COLUMN

Operating & Maintenance Manual. Automatic Medical Gas Manifold Digital Dome Loaded Regulator NFPA v1.5

Automatic Medical Gas Manifold Dome Loaded Regulator NFPA v1.1

V4043 and V4044 Motorized Valves

Spectra EA Series. the right connection. product benefits. Horizontal positioning radius of 81 (205 cm) Vertical positioning range of 27 (68 cm)

Servicing Instructions

Installation Instructions. ARS (Amico Rail Systems)

6 Bay Battery Charger Operation Manual

Hospital Bed Collection. Amico Care Series Mobility - Simplicity - Versatility

OPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH

Stretchers. Titan Transport and Titan Bariatric

The world's smallest 700 lb patient lift... Weighs less than 10 lbs!

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

Installation Operation Maintenance

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve

A-320 Balanced 1st Stage

LLS-2054BE. Smart Battery Pack Operator Manual. ST Technologies 6018 Bowdendale Avenue Jacksonville, FL USA

1 - S-2251 Showerhead 6 - S-2288 Showerhead AP - Anchor Plate (S-2280 Showerhead Only)

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA Tel: Ref.

Temperature Sensor Series

Installation, Operation, and Maintenance Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Welker Gas Sampler Model MPS-2

SERVICE MANUAL. DiamondCare Recessed Wall Outlet and Electrical. MAN Rev. B

Welker Probe Instrument Regulator with Liquid Eliminator Cartridge

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Model INTERNAL/BOTTOM LOADING VALVES SM Maintenance & Repair Manual. July Applicable addition manuals: None

MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody

2200 North Main Street Washington, PA PH: FX:

CAB TILT HYDRAULIC SYSTEM

Temperature Regulators

DECLARATION OF CONFORMITY FOR THE MEDICAL DEVICE FAMILY OUTLETS FOR COMPRESSED MEDICAL GASES AND VACUUM AND FOR ANAESTHETIC GAS SCAVENGING SYSTEMS

Service Handbook High-Pressure Washer Pump

T60 REGULATOR REPAIR KIT INSTRUCTIONS

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Welker Automatic Insertion Diffusing Probe Model AIP-3DP

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material

Operating Instructions. International English. CCS Dust Extractor

No Infrared Refrigerant Leak Detector

TECHNICAL DATA 1-1/2 (dn40)

Type 289P Pilot-Operated Relief Valve

250L Cartridge Dual Seal

5020 Series Injector

SERVICING INSTRUCTIONS

Maintenance & Repair Manual

Model 210HP Beadbreaker

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Maintenance Information

CYLINDER VALVES. Assembly & Maintenance Guide

Troubleshooting the Transmission Hydraulic System

TECHNICAL DATA OBSOLETE

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Installation Guidelines

Installation Instructions

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER PROBE MOUNTED LIQUID ELIMINATOR

Supplies Required. Teflon Tape Allen Key Wrenches Screwdriver 1/2" NPT Brass Pipe Plug Adjustable Wrench IMPORTANT!

Service Manual Air Tech Second Stage

Model 605 Portable Aspirator

MEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.

2 CYLINDER MOBILE CART ASSEMBLY INSTRUCTIONS

Adjustable Differential Relay A1

Operating & Maintenance Manual For Steam Conditioning Valve

TOYOTA COROLLA LOWERING SPRINGS Preparation

EZ-IN Series Turbine Flowmeter

Wastewater Combination Air Valve. Operation, Maintenance and Installation Manual

SV HIGH VACUUM (Positive Relief) SEAL-OFF VALVE 1 Inch Size

MODEL 905V OPERATING INSTRUCTIONS

FkcoqpfEctg Eqpuqng Qwvngv

QA4 Surgery Trolley System Manual Function Operating Instructions

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

MAINTENANCE PROCEDURE FOR MK17

Operation, Model MPS-2DA. Installation, responsibility

Series Roll Seal

M-5000TG/5700TG Steam and Cold Water Mixing Unit

SAFETY MANUAL READ FIRST!

TECHNICAL INSTRUCTIONS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CRUDE OIL COLLECTION ASSEMBLY HIGH PRESSURE

AVK SAUDI VALVES MANUFACTURING COMPANY

Type 289P Pilot-Operated Relief Valve

Transcription:

Installation and Maintenance Manual Medical Gas Outlet British Standard Slim Style Compatible w w w. a m i c o. c o m

Table of Contents Product Description 3 Cleaning and Lubrication 3 Inspection and Testing 4 Installation and Dimensions Console Mount 5 Surface Mount 6 Service Preventive Maintenance 7 Latch-Valve Assembly 8-10 AGSS Flow Control Adjustment 11 Model Numbers Latch-Valve Assembly 12 Rough-in Assembly 12 Complete Outlets 12 Gas indexing 13 Replacement Components Gas Latch-Valve Assembly 14 Vacuum Latch-Valve Assembly 15 AGSS Latch-Valve Assembly 16 Rough-In 17 2 Amico Corporation

Product Description The Amico Medical Gas British Outlet Slim Style is composed of two separated modules: the Rough-in Assembly and the Latch-Valve Assembly. The Rough-in Assembly consists of a brass machined body that incorporates a spring loaded check assembly. The copper pipe is sliver brazed into the body and flared to 12 mm inside diameter for external pipeline connections. The brass body and pipe assembly are inserted in to a gas specific plate. The Rough-in Assembly has a colour coded label on the front plate and the copper pipe, so that the installer can easily identify the gas that the copper pipe should be connected to. The Rough-in Assembly incorporated a check valve that allows the Latch-Valve Assembly to be removed for service, without requiring the pipeline to be shut down. The Rough-in Assembly has a DUAL pin gas specific indexing arrangement to prevent the wrong Latch-Valve assembly from being plugged into the Rough-in Assembly (see page 17). The Latch-Valve Assembly is manufactured with a gas specific housing which accepts, retains and releases the probe, indexed on the back side to match gas specific indexing of the Rough-in Assembly. CAUTION: DO NOT over tighten the Latch-Valve mounting screws! Distortion of the Latch-Valve can occur. Outlets are available for oxygen, medical air, surgical air, nitrous oxide, medical vacuum and anesthetic gas scavenging system. These are designed in accordance with HTM 02-01 and ISO 9170. Cleaning and Lubrication The Amico British Slim Style Outlets are factory cleaned for oxygen service. Exposed surfaces of the Outlet may be cleaned with a mild detergent solution or wiped with a disinfectant commonly used in patient rooms, which is compatible with plastic, anodized aluminum and die cast zinc. Lubricate elastomer seals sparingly with silicone lubricant that is oxygen compatible. DO NOT USE OIL www.amico.com 3

Inspection and Testing Pressure drops across the Amico British Outlet shall comply with ISO 9170 Standards. Terminal Unit Nominal Distribution Pressure (kpa) Test Pressure (kpa) Test Flow (1/min) Maximum Pressure Drop Across a Terminal Unit (kpa) 400 to 500 320 40 15 400 to 500 320 200 70 700 to 1,000 560 350 70 * Absolute pressure Vacuum *40 25 15 AGSS Requirements for flow and pressure drop across terminal units with probe inserted ISO 9170 Standards. Terminal Type Test Pressure Test Flow (1/min) Maximum Pressure Drop Across a Terminal Unit (kpa) 1 Atmospheric pressure 90 15 Note: The Amico British Slim Style Outlets meet and exceed the requirements at the time of manufacture. However piping source capacity, sizing and restrictions my prevent outlets form attaining these values. Installation and Dimensions The Amico British Slim Style Outlet should be mounted at a height of between 900 mm and 1400 mm above finished floor level and not less than 200 mm from any obstruction. Where more than one Outlet unit is to be mounted in one location, these should be mounted at the following spacing; Two Outlet units 150 mm centres Three or more Outlets units 135 mm centres Outlet units mounted in a horizontal array shall be installed in the following sequence when viewed from the front, left to right; O₂ N₂O; 50% O₂/50% N₂O; Medical Air, Surgical Air, Vacuum; AGSS Please refer to HTM 02-01. 4 Amico Corporation

Installation and Dimensions Console Mount www.amico.com 5

Installation and Dimensions Surface Mount 6 Amico Corporation

Preventative Maintenance Regular inspection and maintenance of the Outlets will prolong its life and reduce the possibility of sudden, inconvenient component failures. The use of damage probes or faulty equipment may require further maintenance. Outlets should be subjected to regular inspection and testing as follows: Monthly; a. Visually inspect the Outlet for signs of damage. b. Check to see if the Front Latch Assembly (2nd Fix) operates smoothly with the gas specific probe. c. If there is any disagreement with the operation of the Front Latch Assembly (2nd Fix), remove the unit for closer inspection/repair/replacement if necessary. Annually; a. Remove Trim Plate and clean debris from the mounting box. b. Remove Front Latch Assembly (2nd fix) and inspect the barrel for any damage. c. Inspect the Rough-in Assembly (1st fix) for any damage. If damage or leaking replace components. d. Test Front Latch Assembly (2nd fix) for correct operation (connection and disconnection of the probe) using a blank probe. www.amico.com 7

Gas Latch-Valve Assembly 5 9 10 11 4 2 6 7 8 1 3 1. Unscrew the two Surface Box Cover screws (1), and remove the Surface Box Cover (2), or pry off Trim Ring (3) with a flat screw driver. 2. Unscrew the two Retaining screws (5) until the Latch-Valve Assembly (4) can be removed from the Outlet. 3. Remove the two Retaining washer screws (11), and remove the Retaining washer (10). 4. Remove the Gas Connector (8) 5. Remove the Body Seal (6), and the Poppet O-Ring (9), then the Poppet (7) from the front of the Gas Connector (8). Inspect the items for wear or damage and replace if needed. 6. Re-install all internal components into the Gas Connector (8). Poppet (7), then install Poppet O-Ring (9), then inset Body Seal (6) are in place. Re-install the round Retaining washer (10) and secure with two Retaining washer screws (11), do not over tighten. 7. Re-install the Latch-Valve Assembly into the outlet. Coat the Gas Connector (8) with a thin coat of oxygen compatible silicone lubricant to aid insertion. Tighten down the Retaining screws (5), DO NOT over tighten, as this could damage the Latch-Valve Assembly 8. Re-install Surface Box Cover (2), install Surface Box screws (1) and tighten down (DO NOT OVER TIGHTEN) or reinstall Trim Ring (3). 9. Connect gas specific adapter into the outlet. The connection should be smooth and the adapter should lock and remain in place allowing gas to flow. If not, replace the entire Latch-Valve Assembly (4). 8 Amico Corporation

Vacuum Latch-Valve Assembly 12 2 4 5 6 7 8 9 10 11 1 3 NOTE: Suction Outlets do not have a secondary check valve. Suction source to the Vacuum Outlet must be turned off before removing the Latch-Valve Assembly 1. Unscrew the two Surface Box Cover screws (1), and remove the Surface Box Cover (2), or pry off Trim Ring (3) with a flat screw driver. 2. Unscrew the two Retaining screws (5) until the Latch-Valve Assembly (4) can be removed from the Outlet. 3. Remove the Primary Vacuum Spring (12), and inspect for damage replace if needed. 4. Remove the two Retaining washer screws (11), and remove the Retaining washer (10). 5. Remove the Gas Connector (8) 6. Remove the Body Seal (6), and the Poppet O-Ring (9), then the Poppet (7) from the front of the Gas Connector (8). Inspect the items for wear or damage and replace if needed. 7. Re-install all internal components into the Gas Connector (8). Poppet (7), then install Poppet O-Ring (9), then inset Body Seal (6) are in place. Re-install the round Retaining washer (10) and secure with two Retaining washer screws (11), do not over tighten. 8. Re-install the Primary Vacuum Spring (12). 9. Re-install the Latch-Valve Assembly into the outlet. Coat the Gas Connector (8) with a thin coat of oxygen compatible silicone lubricant to aid insertion. Tighten down the Retaining screws (5), DO NOT over tighten, as this could damage the Latch-Valve Assembly 10. Re-install Surface Box Cover (2), install Surface Box screws (1) and tighten down (DO NOT OVER TIGHTEN) or reinstall Trim Ring (3). 11. Connect gas specific adapter into the outlet. The connection should be smooth and the adapter should lock and remain in place allowing gas to flow. If not, replace the entire Latch-Valve Assembly (4). www.amico.com 9

AGSS Latch-Valve Assembly 13 12 5 4 2 6 7 8 9 10 11 1 3 1. Unscrew the two Surface box Cover screws (1), and remove the Surface Box Cover (2), or pry off Trim ring (3) with a flat screw driver. 2. Unscrew the two Retaining screws (5) until the Latch-Valve Assembly (4) can be removed from the Outlet. 3. After removing the Latch-Valve Assembly (4) from the Outlet, you can then pull the Check Valve Body Assembly from the back side of the Latch-Valve Assembly (4). Remove the Check Valve Body Seals (10 & 11) and check for any abnormal wear or Damage and replace if needed. Coat the O-Ring with a thin coat of oxygen compatible silicone lubricant. 4. Disassembly of the Check Valve Body Assembly: Hold the Check Valve Assembly in one hand, and push down the Check Valve (6) with your thumb of the same hand, compressing the Check Valve Spring (9). Remove the Check Valve O-Ring (13). Release the Check Valve (6) slowly; The Check Valve Body Assembly will fall apart. Inspect parts for abnormal damage or wear and replace. 5. Reassembly of the Check Valve Body Assembly: Re-install the Check Valve Spring (9) onto the Check Valve (6), and then insert them into the Check Valve Body (12). Again, hold the Check Valve Body Assembly in one hand, and push down the Check Valve (6) with your thumb of the same hand, compressing the Check Valve Spring (9). Before reinstalling the Check Valve O-Ring (13), coat the O-Ring with a thin coat of oxygen compatible silicone lubricant. 6. Insert the Check Valve Body Assembly into the back of the Latch-Valve Assembly. 7. Re-install the Latch-Valve Assembly into the outlet. Coat the outer portion of the Check Valve Body Assembly with a thin coat of oxygen compatible silicone lubricant, to aid insertion. Tighten down Retaining Screws (5). DO NOT over tighten, as this could damage the Latch-Valve. 8. Re-install Surface Box Cover (2), install Surface Box screws (1) and tighten down (DO NOT OVER TIGHTEN) or reinstall Trim Ring (3). 9. Connect gas specific adapter into the outlet. The connection should be smooth and the adapter should remain in place allowing flow. If not, replace the entire Latch-Valve Assembly (4). 10 Amico Corporation

AGSS Flow Control Adjustment Referencing Part Numbers: O-BSQSL-SUR-AGS O-BSQSL-CON-AGS A.G.S.S. Threaded Nose Valve Flow Control Screw (3mm Allen Key) Surface Mount Box 1. Insert a 3 mm Allen Key into the front of the Check Valve. 2. Adjust the Flow Control Screw to desired setting. www.amico.com 11

Rough In Assembly 4 1 2 3 CAUTION: Ensure that the supply pressure is shut off before performing service. Inside the Rough-in Assembly is a secondary check valve whose function is to shut off gas flow when the Latch-Valve Assembly is removed. This seal O-Ring also prevents leakage around the latch-valve connector. As the secondary seal is only a static seal, it will rarely need replacement. However, if the seal O-Ring does need replacement, follow the following procedure: NOTE: Suction inlets (Vacuum and AGSS) are not supplied with Secondary Check Valve. The Secondary Check Valve (2) and Secondary Check Valve Spring (3) are not required. 1. Ensure that no pressure exists in the line by depressing the secondary check (2). 2. Removal of Internal components: Depress the Secondary Check Valve (2), with a dull screw driver (prevents damage on the Check Valve), at the same time pry out the Secondary Seal O-Ring (1), with a small screws driver. After the Secondary Seal O-Ring (1) is out. The Secondary Check Valve (2) and Secondary Check Valve Spring (3) are no longer locked in place and can be easily removed. Inspect all components for abnormal wear and replace. 3. Reinstallation if internal components: Install the Secondary Check Valve Spring (3) to the back side for the Secondary Check Valve (2). Then insert into the Rough-in Body (4). Insert Secondary Seal O-Ring (1), while depressing the Secondary Check Valve (2). 4. Turn on the pressure and check for leaks. Re-install the Latch-Valve Assembly and perform then inspection and test. 12 Amico Corporation

Model Numbers Surface Mounted Latch-Valve Assembly Rough-in Assembly Complete Assembly Oxygen O-FASC-BSQSL-OXY O-BAKSUR-BSQSL-OXY O-BSQSL-SUR-OXY Medical Air O-FASC-BSQSL-AIR O-BAKSUR-BSQSL-AIR O-BSQSL-SUR-AIR Surgical Air O-FASC-BSQSL-SAI O-BAKSUR-BSQSL-SAI O-BSQSL-SUR-SAI Vacuum O-FASC-BSQSL-VAC O-BAKSUR-BSQSL-VAC O-BSQSL-SUR-VAC Nitrous Oxide O-FASC-BSQSL-N20 O-BAKSUR-BSQSL-N20 O-BSQSL-SUR-N20 Anaesthetic Gas Scavenging System O-FASC-BSQSL-AGS O-BAKSUR-BSQSL-AGS O-BSQSL-SUR-AGS Console Mounted Latch-Valve Assembly Rough-in Assembly Complete Assembly Oxygen O-FASC-BSQSL-OXY O-BAKSUR-BSQSL-OXY O-BSQSL-SUR-OXY Medical Air O-FASC-BSQSL-AIR O-BAKSUR-BSQSL-AIR O-BSQSL-SUR-AIR Surgical Air O-FASC-BSQSL-SAI O-BAKSUR-BSQSL-SAI O-BSQSL-SUR-SAI Vacuum O-FASC-BSQSL-VAC O-BAKSUR-BSQSL-VAC O-BSQSL-SUR-VAC Nitrous Oxide O-FASC-BSQSL-N20 O-BAKSUR-BSQSL-N20 O-BSQSL-SUR-N20 Anaesthetic Gas Scavenging System O-FASC-BSQSL-AGS O-BAKSUR-BSQSL-AGS O-BSQSL-SUR-AGS www.amico.com 13

Gas Indexing As seen from the front of the Rough-In Assemblies VACUUM OXYGEN NITROUS OXIDE MEDICAL AIR SURGICAL AIR AGSS 14 Amico Corporation

Replacement Components Gas and Vacuum Latch-Valve Assembly 12 4 5 8 9 10 11 2 6 7 1 3 Item Description Model Numbers 1 Surface Box Cover screws (2 req'd) H-STPP-6150AB 2 Surface Box Cover O-X-BSQC-SBX2-375 3 Trim Ring O-X-BSQC-FACTRM2 4 British Standard Slim Style Latch-Valve See Above 5 Outlet Retaining Mounting screws (2 req'd) H-MPP-0608 6 Body Seal O-X-OXE-SEAT* 7 Poppet O-X-BSQC-POPET2* 8 Gas connector O-X-BSQC-VLV2 9 Poppet O-Ring H-ORING105VTN* 10 Retaining washer O-X-BSQC-WASH 11 Retaining washer screws (2 req'd) H-HLTPP-04037 12 Vacuum spring (Only used for Vacuum Outlet) O-X-LVAPB-SPGAS* Above parts with and * are found in repair kit: O-RK-LVA-BSQSL www.amico.com 15

Replacement Components AGSS Latch-Valve Assembly 2 4 5 6 7 8 9 10 11 12 13 1 3 Item Description Model Numbers 1 Surface Box Cover screws (2 req'd) H-STPP-6150AB 2 Surface Box Cover O-X-BSQC-SBX2-375 3 Trim Ring O-X-BSQC-FACTRM2 4 British Standard Slim Style Latch-Valve See Above 5 Outlet Mounting screws (2 req'd) H-MPP-0608 6 AGSS Check Valve O-X-BSQC-CHKVLV 7 Flow Adjustment screw H-HSSS-CPM601-6SS 8 Locking screw H-HSSS-CPM601-6SS 9 AGSS Check Valve Spring O-X-BSQC-VLV-SPR* 10 Check Valve Body Seal H-ORING-020VTN* 11 Check Valve Body Seal H-ORING-020VTN* 12 Check Valve Body O-X-BSQC-LATCH2 13 Check Valve O-Ring O-X-LVAQ-ORING* Above parts with and * are found in repair kit: O-RK-LVA-BSQSL-AGS 16 Amico Corporation

Replacement Components Rough-in Assembly 4 3 1 2 Item Description Model Numbers 1 Secondary Seal O-Ring H-ORING-115VTN* 2 Secondary Check Valve O-X-BSQC-BKCHK2* 3 Secondary Check Valve Spring O-X-BSQC-BAKSPR* 4 Rough-in Body See above Above parts with an * are found in repair kit: O-RK-BAK-BSQSL www.amico.com 17

www.amico.com Amico Corporation www.amico.com 85 Fulton Way, Richmond Hill Ontario, L4B 2N4, Canada Toll Free Tel: 1.877.462.6426 Toll Free Fax: 1.866.440.4986 Tel: 905.764.0800 Fax: 905.764.0862 Email: info@amico.com Authorized Representative: RMS-UK Limited 28 Trinity Road Nailsea, Somerset BS484NU England Phone & Fax: 01275 858891 APE-INSTAL-MANI-BRIT-STD-OUTLET-SLM 10.26.2015