IMPORTANT ATTENTION INSTALLERS:

Similar documents
LIGHT COMMERCIAL - 3 HP ECM MOTOR / CONTROLLER HIGH STATIC DRIVE KITS

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

Technical Manual. DLM Module. This manual should remain with the unit.

Installation Instructions

Installation Instructions

Applies to: Models F, B, FE, and BE with spark pilot

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Owner's/Installation Manual

Installation Instructions

Installation Instructions

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

Installation Instructions

Owner s Information Manual

SERVICE INSTRUCTIONS

EconoMi$er, Power Exhaust, and Sensor Installation Instructions

INSTALLATION INSTRUCTIONS

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

Gas Conversion Kits and Instructions

Package Unit Modulating Economizer Installation Instructions

Package Unit Modulating Economizer Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PARTS LIST INSTALLATION INSTRUCTIONS AIR CONTROL KIT (800A0168 OR 800A0169)

Installation Instructions

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

INSTALLATION INSTRUCTION

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

Installation, Operation and Maintenance Manual

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

MODEL SCA Installation and Operation Manual Important:

Installation Instructions

Installation Instructions

PRODUCT SAFETY NOTICE

Electronically Commutated Motor Wiring Manual

Supplemental Installation Instructions -- August 2016

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

PS1201A00, PS1202A00 and PS2401A00 Replacement Power Supplies for Electronic Air Cleaners

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

Supplemental Installation Instructions -- August 2016

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

Checker Unload Checkstand Installation Instructions

Lbs Kgs Ft M

INSTALLATION INSTRUCTIONS

Installation Instructions

Q7RE Series Single Packaged Heat Pump, Single Phase

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

INSTALLATION INSTRUCTIONS

FITTNING INSTRUCTIONS

PRODUCT SAFETY NOTICE DEALER/INSTALLER NOTICE

Installation and Start-Up Instructions

Safety & Installation Instructions

Q7RE Series Single Packaged Heat Pump, Single Phase

Installation and Start Up Instructions

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS

CHROME ALLEY CAT L.E.D. FUEL & BATTERY GAUGE 7381

Installation Instructions

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102

SCION tc SECURITY (V5) Preparation

ZHA/ZHB SERIES WARNING

BCFS Belt Driven Centrifugal Filtered Supply Fans

MicroMetl INSTALLATION INSTRUCTIONS FOR 0689ZJ36EC

Installation instructions for KIT15017, KIT15018, KIT15019, and KIT15020

SYST0101ZP Ion Damper Control Installation and Start---Up Instructions

Source Capture Air Purification System

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

MODEL ELC-12/60-D BATTERY CHARGER

TOYOTA TUNDRA TVIP V4 Preparation

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Installation. Check, Test & Start Procedure

SLIMZONE CLASSIC /

LOW AMBIENT ACCESSORY INSTALLATION INSTRUCTION

RANGER 900 POWER STEERING KIT

EasyStart Installation Instructions for Dometic Family RV A/Cs

ATV/UTV WINCH INSTRUCTION BOOK 3000 LBS

TOYOTA TACOMA TVIP V5

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation Instructions

Ford 6.7 EGR Delete Kit

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps

D5W Z Auxiliary Heater Upgrade D5W Z Auxiliary Heater to Auxiliary Preheating System C

Installation Instructions

Symmetra PX. 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V. Receiving and Unpacking 01/2016.

Galaxy Receiving and Unpacking 09/

P7RE Series Single Packaged Air Conditioner

INSTALLATION GUIDE. Universal System for Zero Turn Mowers

Transcription:

Power Exhaust Kit for P7TQ, Q7TQ & R7TQ Series INSTALLATION INSTRUCTIONS IMPORTANT ATTENTION INSTALLERS: It is your responsibility to know this product better than your customer. This includes being able to install the product according to strict safety guidelines and instructing the customer on how to operate and maintain the equipment for the life of the product. Safety should always be the deciding factor when installing this product and using common sense plays an important role as well. Pay attention to all safety warnings and any other special notes highlighted in the manual. Improper installation of the furnace or failure to follow safety warnings could result in serious injury, death, or property damage. These instructions are primarily intended to assist qualified individuals experienced in the proper installation of this appliance. Some local codes require licensed installation/service personnel for this type of equipment. Please read all instructions carefully before starting the installation. Return these instructions to the customer s package for future reference. DO NOT DESTROY. PLEASE READ CAREFULLY & KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

IMPORTANT SAFETY INFORMATION Please read all instructions before servicing this equipment. Pay special attention to all safety warnings and any other special notes. Safety markings are used frequently throughout these notes. Safety markings are used frequently throughout these instructions to designate a degree or level of seriousness and should not be ignored. WARNING indicates a potentially hazardous situation that if not avoided, could result in personal injury or death. CAUTION indicates a potentially hazardous situation that if avoided, may result in minor or moderate injury of property damage. WARNING: ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury or property damage. Improper servicing could result in dangerous operation, serious injury, death or property damage. Before servicing, disconnect all electrical power to furnace. When servicing controls, label all wires prior to disconnecting. Reconnect wires correctly. Verify proper operation after servicing. WARNING: The safety information listed below must be followed during the installation, service, and operation of this furnace. Unqualified individuals should not attempt to interpret these instructions or install this equipment. Failure to follow safety recommendations could result in possible damage to the equipment, serious personal injury or death. CAUTION: To avoid personal injury or property damage, make certain that the motor leads do not make contact with any uninsulated metal components of the unit. Before beginning the installation, verify the unit model number. The unit model is printed on the data label. Follow all precautions in the literature, on tags and labels provided with the equipment. Read and thoroughly understand the instructions provided with the equipment prior to performing the installation and operational checkout of the equipment. Use caution when handling this equipment or removing components. Personal injury can occur from sharp metal edges present in all sheet metal constructed equipment. Before installation, verify that the economizer ordered is the appropriate size for the unit. Inspect packing for damage or forced entry. Verify that all parts requested are accounted for. See Table 1 and Figure 8 (page 6). ABOUT THE KIT The power exhaust can be used in down flow economizer applications. This power exhaust is designed to relieve excess pressure that may occur with economizers or certain building conditions. All fan motors are recognized by UL. Permanently lubricated ball bearing and motor overload protection are standard. These instructions pertain both to the field installed and factory installed Power Exhaust options (hereafter referred to as the PE ). Due to shipping requirements, factory installed power exhaust hoods are shipped loose, with the wiring internal to the unit completed. These instructions supplement those in 1011418 economizer kit, a required accessory to the PE. Ideally this installation should be conducted after all the steps from the economizer installation are completed, except for the installation of the barometric relief hood. P/N DESCRIPTION QTY 1012664 Power Exhaust Hood Top 1 1012665 Power Exhaust Hood Bottom 1 1012666 Power Exhaust Hood Right Side 1 1012667 Power Exhaust Hood Left Side 1 1012893 Power Exhaust Fan Brace 1 667364 Fan Blade, 3 Propeller (072 Model) 1 Fan Blade, 4 Propeller 271835 (090-150 Models) 1 205628 3/4 HP Fan Motor (208-460V) 1 622545 Capacitor (208-460V) 1 1012078 3/4 HP Fan Motor (575V) 1 622549 Capacitor (575V) 1 285934 Capacitor Strap 1 157107 Motor Mount 1 1013109 Neoprene Isolator 4 669335 Fan Grill 1 295481 Fan Orifice 1 624830 Contactor, 2 Pole 1 1012668 Contactor Bracket 1 038157 Strain Relief Bushing, Snap-in 1 1013012 Liquid Tight Fitting, 1/2 NPT 1 1013752 Installation Manual 1 600255 #10-24 UNC x 1/2 lg, Sheet metal Screw 70 600223 5/16-18 UNC x 3/4 lg, Hex Head Cap Screw 8 612011 5/16 Flat Washer 12 631591 Tie Wrap - 6 6 606291 1/2 Nylon Clamp 6 631337 Closed End Wiring Connector 5 Table 1. Materials List 2

KIT INSTALLATION 1. Verify that the MCA and MOP of the installed unit will not be affected appreciably by the addition of the PE option. 2. Unpack and inspect all components for completeness and shipping damage. If any component is damaged, report it immediately to the last carrier so that a claim can be made against the transportation company. 3. Open and lock the unit disconnect switch before attempting to install this accessory. NOTE: If this PE Option was factory installed, skip to step 9 of these instructions. 4. Open the control compartment access doors and identify the mounting location of the PE contactor and bracket. Now install the PE contactor and bracket using the provided screws as shown in Figure 1. Figure 2. Power Wire Location 10. Install the capacitor bracket, brace, fan shroud and guard. 11.Install (4) vibration isolators in the fan panel, ensuring that the outward lower bolts pass through the brace. CAUTION: Misalignment of the motor and blade spacing will cause the blade to contact the grille, shroud and / or basket, causing damage and possible personal injury. Figure 1. Contactor Location 5. Using the supplied wiring leads, connect the tapped power wires from the unit terminal block to the line (right) side of the contactor and the 24 V control wires as shown in the wiring diagram. See Figure 7 (page 5). 6. Locate the two unused black wires in the compressor compartment. Remove the tie wraps securing them. Route the wires into the control compartment through the opening beneath the PE contactor. 7. Connect the 1/4 QC terminals of the two black wires to the load (left) side of the PE contactor. Secure any loose wires with the provided tie wraps. See Figure 2. 8. Move to the economizer section of the unit. Now locate and remove the 1/2 dia. knockout on the economizer damper left side. CAUTION: To avoid personal injury, two people are required to install the hood. 9. Remove the PE hood top from the hood assembly. Now working beneath the economizer intake hood, install the PE side panels and fan (lower) panel. 12. Install one washer on each bottom bolt. NOTE: Measure and confirm that the motor and blade spacing matches the to within +/- 1/16 as shown in the Power Exhaust Assembly drawing (no. D303199). See page 6. 13. Install the fan subassembly as shown in Figure 3. NOTE: Fan assembly may be pre installed. Figure 3. Fan Subassembly Installed 3

e.) Navigate to the CHECKOUT menu and initiate the DAMPER OPEN test. Verify that the damper opens fully and that the exhaust fan energizes. f.) Navigate to the SET POINTS menu and then to the EXH1 SET parameter. Toggle this parameter from 50 to 80. g.) Return to the main menu; the PE is now configured to energize at the 80% damper command setting. If the building conditions dictate, the EXH1 SET value may be changed to reduce the building pressures at a lower command percentage. h.) Close the filter access door. Verify and adjust the building S.P. and unit cfm as needed. i.) Place the unit back in service. Store all the Economizer and PE literature with the unit manuals. Figure 4. Two Pin AMP Plug Location 14. Install two washers on each top bolt. 15. Using a long tool, (such as a screwdriver), manually spin the fan blade to verify that no moving part contacts any other parts. Now wait for the fan to stop spinning before proceeding to the next step. 16. Locate the two-pin AMP plug in the upper right side of the filter compartment and remove any tie wraps securing the plug and wires. See Figure 4. 17. Connect the mating AMP plug from the PE kit. Route and secure the two black wires to the PE fan assembly as shown in Figure 5. NOTE: Make sure to install the provided strain relief bushing in the 1/2 dia. knockout removed in step 8. NOTE: It may be required to use fish tape or similar to route the wires through the 1/2 dia. knockout. 18. Install the 1/2 NPT bushing into the motor connection box. Route the two (2) black wires through the bushing. Remove the motor connection box cover and make the wiring and capacitor connections per the supplied wiring diagram. Reference the motor connection box cover for the wiring based on supply voltage. Use the provided closed end connectors. 19. Replace the motor connection box cover. Secure the wiring using the provided tie wraps. Recheck the fan rotation and clearance as per instructions in steps 10 & 11. 20. Verify that all the connections are correct. 21. Install the PE hood top panel and close all access panels. See Figure 6. 21. Return power to the unit and setup the economizer controller for PE operation as follows: a.) Verify that there is not a call for heat, cooling or blower. b.) Review the manual for the Honeywell JadeTM Economizer Module to determine the basic operating procedures and the menu structure. c.) Open the filter access door, it contains the Honeywell JadeTM Economizer Module. d.) Navigate to the STATUS menu and EXH1 OUT parameter. Toggle this parameter from OFF to ON. Figure 5. Connector Connection Figure 6. Final Assembly 4

WIRING CODE BLACK - BK BROWN - BR RED - RD ORANGE - OR YELLOW - YE GREEN - GN BLUE - BL VIOLET - VI WHITE - WH GRAY - GR TERMINAL BLOCK -- UNIT PANEL (HIGH VOLTAGE SECTION) TERMINAL BLOCK -- UNIT PANEL (LOW VOLTAGE SECTION) 10137510 Figure 7. Wiring Diagram 5

POWER EXHAUST HOOD TOP STRAIGHT FITTING FAN MOTOR FAN SUPPORT ASSEMBLY POWER EXHAUST HOOD RIGHT SIDE FAN POWER EXHAUST FAN PANEL RUBBER ISOLATOR BRACE - POWER EXHAUST ORIFICE ASSEMBLY (24 ) POWER EXHAUST HOOD LEFT SIDE FAN GRILLE (24 ) Figure 8. Power Exhaust Component Locations 6

7

Specifications & illustrations subject to change without notice or incurring obligations (03/18). O Fallon, MO, Nortek Global HVAC LLC 2018. All Rights Reserved. 1013752A (Replaces 10137520)