SpeedSec BP Automatic Barrier System

Similar documents
Gunnebo SpeedStile FL. BA/EV Series. Flap Leaf Speed Gate for Internal Installation

SlimStile EV. Tripod Turnstile for Internal or External Installation (*)

RevoSec. Manual Full-Height Turnstile for Internal Installation. Passage in both directions is electronically controlled.

RevoSec. Manual Full-Height Turnstile for Internal Installation. Passage in both directions is electronically controlled.

RevoSec. Manual Full-Height-Turnstile for Internal Installation

Flight Systems. Replacement for KASSEC DESCRIPTION

REXON TURNSTILE. Security without compromising

SlimStile EV. Tripod Turnstile for Internal or External Installation*

PEDESTRIAN ENTRANCE CONTROL

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm)

RotaSec FOS. Manual Full-Height Turnstile for External Installation. Passage in both directions is electronically controlled.

(1032 mm) 30.5 (775 mm) 44 ( mm)

RevoSec. Manual Full-Height Turnstile for Internal Installation

ROAD BLOCKERS BOLLARDS ARM BARRIERS TYRE KILLERS.

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

MEESONS SPECIFICATION BROCHURE EASYGATE SPEED GATE RANGE SPECIFICATION BROCHURE

Application. Battery. Public Grid GS HYBRID INVERTER

MST. model. alvaradomfg.com

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

MAG. FLB100 series Pedestrian Automatic Flap Barrier. General Description. Application. Features. Specification sheet. Date: April 2012, Revision: V1

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

EDC-E. Waist HIGH Turnstiles. alvaradomfg.com

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

PG300 Data Sheet PG300 DATA SHEET

Operating Instructions Type MPT 53

Product facts Geryon SRD Security Revolving Doors STS Security Turnstiles

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

Photovoltaics. MPI Hybrid Series

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Operating Instructions Pedestrian Turnstile Type MPT 33

MST FULL HEIGHT TURNSTILES TYPICAL INSTALLATION SITES COMMON APPLICATIONS DESCRIPTIVE SPECIFICATIONS ALVARADOMFG.COM

MST. Full Height Turnstiles. alvaradomfg.com

91 (2311 mm) (1581mm) (1375 mm)

TURNSTILES GA2-TM-(DA) CATALOGUE GASTOP PREMIUM

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

GCU-10. Automatic Engine Control Unit Operators Manual

WIRELESS CONTROL MODULE (WCM)

Transparent Charon turnstiles Stylish Perfectly coordinated Timeless

PPU Diesel Power 50/60Hz Containerized Generator Set

INVEOR "Smart connections." on five levels

TRAFFI BARRIE COST EFFECTIVE BARRIER SOLUTIONS TRAFFIC BARRIERS

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

SCCP PWM Charge Controller/Load Manager Owner s Manual

User Manual Rittal PMC UPS 6kVA

Common features. Installation options. Aesthetic options

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Manual and Remote Start Unit with Key Switch, 72x72 DIN Size

UPS. MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

User Manual. Solar Charge Controller 3KW

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Product Cross Reference

Mobile Access, TimeTec Smart Tripod Turnstile TTS 2200B Installation Manual

Application Engineering Europe

Type A - PICV Actuator Series

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

Installation Guide B-BOX Pro2.5 ~ 10.0

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

MCD Pump Application Module

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW

K25000 & KD25000 Series

GS2 Series - Introduction

Choose the future Choose

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

RVS-DN Digital Reduced Voltage Motor Starter

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

INSTRUCTION & INSTALLATION

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

CAM-PTZ-AUT Tracking Module for PTZ Camera Installation & User Manual

USERS MANUAL MCD REMOTE OPERATOR

CX-SERIES ADVANCED BATTERY CHARGER

Liebert PowerSure PSI UPS

Electric actuators type EA25-250

Lighted PushButton Switch

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Technical Specification SENTINEL PRO

TECHNICAL DATA SHEET KVA UPS Systemss

APEM LPI series Front or rear mounting Illuminated or non-illuminated Flexibility of marking Meeting the requirements of EN81-70 Ø 35 mm actuator

SNMP dedicated to ORVALDI Solar Infini

VEHICLE AND PEDESTRIAN CONTROL

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

PowerCommand 1.1 control system

1 / Genset general description

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

SYSTEM COMPONENTS DIALOCK HOTEL

Transcription:

SpeedSec BP Automatic Barrier System Power Requirements 110/220V. 60/50Hz. AC (%±10) 24V.DC -At standby ~10W. During operation ~39W. (Single-sided) -At standby ~20W. During operation ~78W. (Central unit) Dimensions Single unit: 1465 x 1030 x 325 + arm length (275) mm Central unit: 1465 x 1030 x 325 + arm length (275 x 2) mm Wing Movement Wing Features Top Lid Body Features Electronically controlled rapid wing movement for quick and smooth passage. RGB LED illuminative, 10mm thick tempered glass (impact resistant). 20mm thick natural granite (Star Galaxy Black) stone on top is a standard feature for a decorative and aesthetical appearance. Different granite patterns and colours are available. (Opt. Stainless steel or wood) The central and front panels are DIN 304-Grade satin finished stainless steel; lateral panels are standard grid 304-Grade stainless steel. Stainless steel and acrylic plates for both directions are provided with the top lid for covering reader devices. Adequate space is available under these plates for installation of various reader devices and wiring. Acrylic plates are recommended for the integration of RF units. Indicator & Display Features On the front panels, graphical LED status displays of Green Arrow and Red Cross are provided as standard feature. In addition, an illuminated plexiglas layer under the granite top lid is included. At standby, the plexiglas layer illuminated in blue; during authorised passages it flashes green; when an unauthorised attempt is detected or during alert mode it flashes red. Version: changed: 04.11.2014 page 1 of 6

Operating Temperature, Humidity, IP Rating, MCBF -20 C to +68 C / RH 95% non-condensing / IP 44 Indoor Model / 1M cycles Control System All inputs are opto-coupler protected.controlled by dry contact or grounding input. Compatible with all access control systems that provide dry contact or grounding outputs. Optional RS232/RS485/TCP IP control module is available. System Features& Operation Normally Closed Position: The wings are closed crossing the lane at standby. Wings open rapidly to allow passage when input is received by either direction. Internal dip switch selectable free passage by photocell detection, restricted access, controlled access on both or single direction modes are built in features. Increased lane security can be adjusted via dip switch settings. Output Data Emergency Mode The system provides dry contact passage feedback by relays. The system allows free passage by opening the wings while turning all indicators and wings green upon receiving emergency input from an alarm system. Wings open automatically in case of a power failure in default fail-open mode (powered by internal back-up battery). User can select fail-closed mode by internal dip witch. Wing Speed Flow Rate Wing speed is electronically controlled by adjustable PWM motor drive system. -Wing Opening Speed= ~0,8 seconds by default, ~0,6 1,5 sec. adjustable. -Wing Closing Speed= ~0,8 seconds by default, ~0,6 1,5 sec. adjustable. The above figures for standard tempered glass wings. Capacity of Mechanism: ~1-120 passages/minute; Nominal: ~25-50 passages-perminute. (Recommended reference figure). Utilisation of different access control units can change the flow rate. Standard Features Dot matrix direction and status indicators, natural granite top lid, stainless steel and acrylic reader cover plates for both directions. Optional Accessory and Applications Tempered glass side (lateral) panels, Remote control unit, interface unit for PC, RS485, RS232 and LAN, counter, audio-messaging system, alarm sensor, floor mounting plate, coin slot/intelligent coin system and coin box, separator, card reader pole. Version: changed: 04.11.2014 page 2 of 6

Technical Drawings 1465 mm 1030 mm 1030 mm 275 mm 325 mm 1465 mm 275 mm 325 mm 275 mm Version: changed: 04.11.2014 page 3 of 6

Floor construction & installation plan 20 - (50) mm 20 - (50) mm 325 mm 275 mm 275 mm 325 mm 275 mm 275 mm 325 mm 1030 mm 895 - (925) mm 895 - (925) mm 2115 mm 20 mm 325 mm 275 mm 275 mm 325 mm 275 mm 20 mm 275 mm 325 mm L (R) Centre R (L) 570 mm 570 mm Version: changed: 04.11.2014 page 4 of 6

Mounting Details *Floor level must be flat. BASE adjusters BASE ADJUSTMENT SCREW CABLE Cable PASSAGE Entry Holes AREA MOUNTING Floor fixing HOLES holes BASE JUSTIERSCHRAUBE BASE ADJUSTMENT SCREW 310 mm 155 mm 155 mm 147,1 mm 122 mm 788,1 mm 122 mm 147,1 mm 908,1 mm 1446,3 mm Bottom Mounting Bracket S2 R1 P1 S2 R1 P1 S1 S1 Code S1 P1 R1 S2 Name Mounting Accessories Ø10x150 Gewindestift M10 Unterlegscheibe M10 Federring M10 Mutter Anzahl 8 8 8 8 Version: changed: 04.11.2014 page 5 of 6

Card reader cut out dimensions Top View Side View Version: changed: 04.11.2014 page 6 of 6