Energetic independence

Similar documents
MODEL PG 180 AP. Powered by: GENERATING SET PERFORMANCE 50Hz 60Hz STANDBY RATED POWER

MODEL PG 150 SP. Powered by: GENERATING SET PERFORMANCE 50Hz 60Hz STANDBY RATED POWER

400 KW / 500 KVA. POWERED by TP-JD400-T3-60-UL. kva 500 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

105 KW / 130 KVA. POWERED by TP-I100-T2-60. kva 130 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 125 Prime Power Factor 0.

GENERATING SET PERFORMANCE

GENSET PRODUCTS 013 2

Mains. Great performances. Attractive coloured display. PLC functions inbuilt. Several I/O with possibility of expansion modules

MODEL : PP 800 SC. Powered by: GENERATING SET PROFORMANCE 50Hz 60Hz PRIME RATED POWER STANDBY RATED POWER

MODEL PG 400 AP. Powered by: GENERATING SET PROFORMANCE 50Hz 60Hz STANDBY RATED POWER

MODEL : PP 600 SP. Powered by: GENERATING SET PERFORMANCE 50Hz 60Hz PRIME RATED POWER STANDBY RATED POWER

ATS - Automatic Transfer Switch. AMF - Automatic Mains Failure. Synchro/Parallel applications like: MPM - Multiple Prime Mover

GENERATING SET PERFORMANCE

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

Rental Power 4BTAA3.3 series engine

PowerCommand 3300 Control Panel. Our Energy Is Working For You.

Rental Power Kubota V2403 series engine

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Automatic Genset Controller, AGC-3 Functional description Display unit and menu structure PID-controller Procedure for parameter setup Parameter list

MODEL PG 2000AC. Powered by: GENERATING SET PERFORMANCE 50Hz 60Hz PRIME RATED POWER STANDBY RATED POWER FUEL 75%

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list

ASC SWITCHBOARD DATA SHEET

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

2000 KW / 2500 KVA POWERED by

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

EG1299. Variable Speed Engine Controller for Telecom Backup Gensets SEDEMAC EG1299 HIGHLIGHTS

DATA SHEET Genset Control Unit, GCU 100

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

TECHNICAL DATA SHEET KVA UPS Systemss

HGM9510 GENSET PARALLEL (WITH GENSET) UNIT USER MANUAL

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Decision-Makerr Paralleling System

Standby Amper VOLTAGE

Rental Power QSL9 series engine

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

DKG-509 AUTOMATIC MAINS FAILURE UNIT

THESEUS. Digital Generator Management DGM-02. THESEUS Generator Management Control. Suits all engine sizes

DKG-707 MULTI GENSET PARALLELLING UNIT WITH J1939 INTERFACE

Standby Amper VOLTAGE

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

DGC-2020 DIGITAL GENSET CONTROLLER

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

OPERATING INSTRUCTIONS ECON-M

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

Diesel generator set QSK60 series engine

PowerCommand iwatch Wireless

Bi-fuel Control System

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

MKN-DSP SERIES - THREE PHASE

BC DIESEL GENERATORS TECHNICAL DATA DIESEL GENERATING SET 60HZ

Be2K-Plus AMF panel control wiring --

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

Advanced Genset Controller, AGC 200 Display readings Push-button functions Alarm handling Log list

PowerCommand 500/550 Remote Monitoring System

THESEUS. Digital Genset Management. Suits all engine sizes. Compatible with engines and governors from all manufacturers.

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

HGM9520 Genset Parallel (With Mains) Unit USER MANUAL. Smartgen Technology

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

Diesel generator set QSK95 series engine

HGM6310D/6320D AUTOMATIC GENERATOR MODULE USER MANUAL

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Diesel generator set QSK78 series engine

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Technical specification

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Diesel generator set QSK60 series engine

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET MPS180S-1E / MPS180-1E

Diesel generator set QSK60 series engine

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Technical Data Sheets

TPD2250H6.3 TECHNICAL DATA

DGC-2020 DIGITAL GENSET CONTROLLER

Generating Rates SERVICE PRP STANDBY. HEAVY RANGE Container Powered by MTU

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Options G4, G5 and G8 Power management Functional description Display units Power management setup Power management functions Parameter lists

Komatsu Power Generation Systems

Remote on/off switch Connector for remote on/off switch available on all models. DIP switch for 50/60Hz selection (48/350 model only)

DEIF A/S. Application Notes. Automatic Gen-set Controller. Single generator set. Automatic mains failure. Parallel with mains (grid)

Technical Data Sheets

Emergency Back-up Power Generation for Water & Wastewater Facilities

Designer s Reference Handbook. Automatic Gen-set Controller/GS Multi-line K SW version 2.40.X. Display unit and menu structure

Diesel generator set QSK78 series engine

1800 KW / 2250 KVA POWERED by

Tier4 certified diesel generator set QSK50 series engine

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

INTECH Micro 2300-RTD6

TLE Series UPS 400/500 kw With eboost Technology

16 KW / 20 KVA POWERED by

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Remote Monitoring System

Transcription:

Energetic independence Control cabinet

Manual - automatic - parallel Control cabinet MANUAL CONTROL CABINET KO-R MRS Manual control cabinet can be mounted on genset or delivered separately. It includes the entire control and management of the engine and generator, and remote start of the genset. By pressing a button (key) genset starts and stops (also from a remote location). Genset can also start and stop by signals to be obtained from the outside (remote start). It consists of a metal electrical cabinet, manual control panel of the genset SMC10, the generator protection circuit breaker, emergency stop key and fuses. The cabinet is ready to connect the power cable for consumers on a copper strip or staples. AUTOMATIC CONTROL CABINET KO-A AMF Automatic control cabinet can be mounted on genset or delivered separately. It includes the entire control and management of the engine and generator, and remote start of the genset. It allows the automatic start of the genset at main power network failure and stop on its return. Automatic control cabinet can operate in the following modes: AUTO / MANUAL / TEST / OFF. Genset management is provided by the keys with mechanical feedback and a large graphic display. Management and control can be run also through remote computer (PC). It is possible to connect generating sets in the network. It consists of a metal electrical cabinet, automatic control panell of the genset SAC35, the generator safety switch, emergency stop key and fuses. The cabinet is ready to connect the cable of the consumers on a copper strip or staples.

Control panel SMC 10 Control panel SAC 35 Optional equipment (controls, SMC, SAC) RS232, RS485, USB Mode Bus Adapter, GSM-modem, software, remote screen, interface for starting the device, internet module, expansion I / O module. Functions / controllers Stubelj SMC 10 Stubelj SAC 35 Binary inputs / outputs 6/6 7/7 Analog inputs 3 3 Magnetic pick-up AMF function - Input configuration Output configuration Voltage measurement Genset / Mains 3 ph/- 3 ph/3 ph Current measurement 3 ph 3 ph, IDMT overcurrent kw/kwh measurement /- / History file - RTC with battery GCB/MCB control with feedback -1)/- / Battery charging alternator circuit J1939 interface - Internet support with IB-LITE with IB-LITE Extension modules - IGL-RA15, IG-IOM, IGS-PTM 8 analog gauge drivers o o RS232 or RS485 interface o o Modem interface o o MODBUS interface o o Remote display o o Cummins Modbus o o Legend: included - excluded o optional - plug-in module required 1) Automatic GCB control without feedback 2) Manual / Automatic GCB control, but without feedback

3ph Microprocessor control Stubelj SMC10 / SAC35 includes the following management and control for the genset: 3 phase AMF function* Over/Under frequency Over/Under voltage Voltage asymmetry 3-phase generator protections Over/Under frequency Over/Under voltage Current/Voltage asymmetry Overcurrent/Overload True RMS Voltage measurement 3 phase generator and mains* voltages Voltage range 277 V p-n, 480 V p-p Maximal measured voltage 300 V p-n PT ratio range 0.1 500 True RMS current measurements 3 generator phase currents Current range 5 A Maximal measured current 10 A CT ratio range 1 5000 Power measurements Act / React Power and Power Factor per phase Active and Reactive Energy counter Event and performance log + RTC Event based history with 119 events Reason, Data and Time + all important values are stored Battery backed-up RTC Test Run scheduler User interface Graphic 128 64 pixels display Multiple language capability Setpoints adjustable via keyboard or PC Buttons with mechanical feedback Inputs and outputs 3 analog inputs (0 20 ma or Resistive jumper selectable) 6 or 7* Binary inputs 6 or 7* Binary outputs Magnetic pick-up input D+ preexcitation terminal Optional 8 analog gauge drive outputs, compatible with VDO, Datcon gauges EFI engine support Cummins MODBUS Engine specific J1939 for all major manufacturers Diagnostic messages in plain text Communication interfaces Optional USB and RS232 plug-in modules MODBUS RTU (requires RS232 module) Internet Mechanical and operation parameters Unit dimension 120 180 mm Sealed front face rated for IP65 Hard plexiglass LCD cover Hard plexiglass LCD cover -20 C +70 C standard version -40 C +70 C low temperature version Power supply voltage 8 36 V Voltage drops shorter than 50 ms do not affect operation * - Only for model SAC 35 +24V OR OR OR PC MODEM SMC/SAC/SPC IG-IB C 8 GAUGE DRIVERS PLUG IN MODULE STOP BINARY INPUTS 6x MRS xx 7x AMF xx POWER SUPPLY 8 to 36 VDC + - ALARM BINARY OUTPUTS (OPEN COLLECTOR) 4x MRS xx 5x AMF xx SMC/SAC GENERATOR RS 232 MAINS INTERFACE PLUG IN MODULE MEASUREMENT VOLTAGE CAN - J1939 I/O EXTENSION OR IG-IOM IGS-PTM IGL-RA15 ENGINE D+ BINARY OUTPUTS (OPEN COLLECTOR) ANALOG INPUTS MEASUREMENT VOLTAGE CURRENT GENERATOR C.B. CONTROL MAINS C.B. CONTROL Aux Alternator Preexcitation Oil pressure Starter Fuel Solenoid 2 RPM 3ph 3ph MAINS LOAD DIESEL/GAS ENGINE GENERATOR J1939 Start/Stop - Speed Request Values + Fault Codes

PARALLEL SYNCHRONIZATION CONTROL CABINET KO-P AMF Automatic sync control cabinet can be mounted on genset or separately. It includes the entire control and management of the engine and generator, and remote start of the genset. It enables the automatic start of the genset when main power network fails and stops on its return. It also enables synchronization of network and genset and parallel operation of the genset and main electric network. The parallel synchronization control cabinet can also cover electrical spikes. In case that the designated facility needs additional electricity, genset in parallel operation can add this deficit to the main electrical grid. Genset can also cover a specific part of the power so that is no need to be collected from the main electricity network and pay credits at a higher rate. Genset performs uninterrupted switching between the network and genset. It is also possible for uninterrupted test of the genset at full or partial load. Genset management is possible by keys with mechanical feedback and a large graphical display. Management and control can be run also through remote computer (PC). It is possible to connect generating sets in the network. It consists of a metal electrical cabinet, parallel control panel of the genset Stubelj SPC50, the generator safety switch, battery charger emergency stop key and fuses. The cabinet is ready to connect the cable to consumers on a copper strip or staples. Parallel control SPC 50 Extensions: 4 analog inputs 0-2400 Ω, 8 digital inputs, 8 binary outputs, 1 analogue output, 4 analog inputs Ω/0-20 ma/0-100 0-250 mv, 8 digital inputs, 8 binary outputs, 1 analogue output, 15 green / yellow / red LED indicators. Communication Extensions: Ethernet / Internet communication supports control of multiple generating sets over the Internet, an active e-mail on error on genset, internet function call / callback. Direct or modem control of multiple generating sets RS232 / RS485 / ModeBus support for direct connection, analog / GSM / ISDN modem support, call-back feature on your modem. Software for PC or PC SCADA. Software for PC for long-term monitoring of events multiple generating sets. Controller software for automatic acquisition of data on multiple genset via modem. Remote display connected via RS232, to transfer all of the displayed values to 1.2 km away - the exact copy of the OSD control.

UPGRADING ATS automatic transfer switch genset / mains Control power (for one genset in parallel with the network): automatic synchronization and control of power, cutting peaks, uninterrupted reverse synchronization, voltage control PF (AVR), basic load export / import. Load sharing (for more isolated parallel operation): automatic synchronization and control of power, voltage and PF control (AVR), active load sharing. Load sharing and power management (for more isolated parallel operation or more motors parallel with the network): automatic synchronization and control of power, voltage control PF (AVR), active load sharing, the sharing of Var (via CAN bus). All data in this catalogue are informative and are subiect to changes without prior notice. Optimizing the number of operating generating sets: power management (via CAN bus) in kw or % of the power, monitoring and control of multiple generating sets via MultiEdit. Austria Hungary Italy Stubelj d.o.o. Anhovo Nova Gorica Udine Trieste Croatia STUBELJ d.o.o., Anhovo 14, 5210 Deskle, Slovenia, EU, tel: +386 5 / 33 10 330, fax: +386 5 / 33 10 349, info@stubelj.si, www.stubelj.si