RENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25

Similar documents
www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

CD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

www. ElectricalPartManuals. com Type AM ,-6 Magne-Biast Circuit Breakers RENEWAL PARTS GENERAL. ELECTRIC GEF-4438A Supersedes GEF-4438

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

www. ElectricalPartManuals. com

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETIC STARTERS

CR193 B,C,D and E Vacuum Limitamp * Contactors

GEF-4647A. GE Drive Systems. Renewal Parts. HEAVY DUTY DC CONTACTORS DS303Al (600V STYLE) DS303Bl (looov STYLE) www. ElectricalPartManuals.

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

Magnetic Overload Relays

920 Remote Control Switches

Low Voltage Power Circuit Breakers

www. ElectricalPartManuals. com RENEWAL PARTS DATA Westinghouse Electric Corporation WESTINGHOUSE EQUIPMENT FOR FURNISHED TO

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

Westinghouse Molded Case Circuit Breakers Engine Generator FG Amperes

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

Industrial Control Transformers

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

Cutler-Hammer. Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers

GENERAL. ELECTRIC RENEWAL PARTS IC302E HIGH VOLTAGE CONTACTORS. EA A-2300V IEl A-4800V l:c a-sooov

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

CATALOG OF REPLACEMENT PARTS HQC QUICKCHILLS. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO FORM (June 2001)

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Instructions for Replacing

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

RENEWAL PARTS ORDER GUIDE. FCV-500 AND FCV-750 VACUUM CIRCUIT BREAKERS WITH STORED ENERGY OPERATOR NO V

Evolution * Series E9000 Motor Control Center

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

PoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Instructions for Installation, Operation and Maintenance of Low Voltage Power Circuit Breakers Types DSII and DSLII

Multi-Pak Group Control

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Q and M-Frame Circuit Breakers Instruciton Leaflet for Alarm Switch and Auxiliary Switch Combinaiton

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

Crane Control Class 6131

Cutler-Hammer I.L. 29C160G WARNING NOTICE 1-0 INTRODUCTION. General Information

www. ElectricalPartManuals. com

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

ARMOR QUICK LOCATOR GUIDE. Belts , 380 Brake Components Brushes Capacitors Car Signal Components...

COM Overcurrent Relay

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

www. ElectricalPartManuals. com outdoor oillnaken type GC aingle tank descrlpllve bullella page l 14.4 lev 100,380 and BOO mva 23 lev 280 mva

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.

SERVICE AND REPAIR PARTS NEMA SIZE 5, SINGLE POLE, NORMALLY CLOSED, P/N SERIES NEMA SIZE 5A, SINGLE POLE, NORMALLY CLOSED, P/N SERIES

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

PowlVac Type PV STD/CDR Vacuum Circuit Breaker

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

S4 N 250 B W - 2 xxx. Isomax. Isomax Molded case circuit breakers S3 S8. MCCBs

Page 1 of 9 Knowledgebase Technote ID # Q /24/2006

Type SOQ Negative Sequence Time Overcurrent Relay

SECTION MOTOR CONTROL

I.L. 29C184A File WARNING

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

CX-Series. Circuit Breaker

SECTION PANELBOARDS

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

[V] Common Control Transformer Control (See page 1-78 Note)

VOYTEN ELECTRIC & ELECTRONICS

Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description

www. ElectricalPartManuals. com MAGNETIC TIME RELAYS GENERAL. ELECTRIC INSTRUCTIONS *IC *Also identified with prefix CR instead of IC.

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

ABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Circuit Protectors CP31F, 32F, 33F

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

SERVICE PARTS MANUAL

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

B CW POWER RELAY

ichards MANUFACTURING COMPANY, SALES, INC. 517 LYONS AVENUE, IRVINGTON, NJ Phone Fax

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065

SERVICE AND REPAIR PARTS NEMA SIZE 3, SINGLE POLE, NORMALLY OPEN, P/N SERIES NEMA SIZE 4, SINGLE POLE, NORMALLY OPEN, P/N SERIES

SERVICE AND REPAIR PARTS NEMA SIZE 5, SINGLE POLE, NORMALLY OPEN, P/N SERIES NEMA SIZE 5A, SINGLE POLE, NORMALLY OPEN, P/N SERIES

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

C E R T I F I C A T E O F C O M P L I A N C E

A Summary of Major Improvements to the ABB Recloser and Type R Breaker

Enclosed Molded Case Circuit Breakers

J lh. NEMA AC Contactors for Motor Loads (Bulletin 500) and Non-motor Loads (Bulletin 500L) Sizes 0 through 4 (all series), Size 5 (series L)

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

Transcription:

Data ubject to change without notice. RENEWAL PARTS POWER CIRCUIT BREAKERS TYPES 225 AMP FRAME SIZE 00 AMP FRAME SIZE GEF-449G Supersedes GEF-449F AK-2-5 AK-2-25 AK-3-25 AKF-2-25 AK-2A-5 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25 Fig.. Type AK-2-25 manually operated power circuit breaker ORDERING INSTRUCTIONS. Always specify the complete nameplate data of the breaker. (PHOTO 802402) 2. Specify the quantity, catalog number (if listed), reference number (if listed), description, and this bulletin number. 3. CAUTION: When local facilities for breaker recalibration are not available, the breaker should be forwarded to the nearest G-E Service Shop, or to the General Electric Company, 90 Elmwood Avenue, Philadelphia 42, Pa. 4. Standard hardware, such as screws, bolts, nuts, washers, etc., is not listed in this bulletin. Such items should be purchased locally. 5. For prices, refer to the nearest office of the General Electric Company. GENERAL. ELECTRIC

GEF - 4490 (PHOTO 802295) fig. 2. Type AK-2-25 power circuit breaker back frame (operating mechanism removed) 5 2 30A 3 --35 33 23 " 29 '-= 3 4 Fig. 4. Cutaway view of type AK-2-25 electrically operated power circuit breaker 2 30 II j r h, Fig. 2A. Spring (back of pivot) 3 7 37 38 39 4 42 27 43 44 2 5 8 9 29?! cf j j 2A Fig. 3. Moving and stationary contacts and cross bar assembly 5 4 4 SA (PHOTO 802425) Fig. 5. Type AK-2-25 electrically operated power circuit breaker (escutcheon removed and dismantled)

Quantity Required Ref. for 3 -pole Breaker Catalog No. Frame Size Number 225 Amp** 00 Amp** la 227D90P Back plate 3 3 29C20G Insulation for upper stud, rear tlb 3 3 29C20G2 Insulation for upper stud, front 2 3-29C2S3G Upper stud assembly 2-3 29C2S3G2 Upper stud assembly 3 3 3 295B40P Barrier *4 3 29C257G Stationary contact assembly 3 29C257G2 Stationary contact assembly *5 * 3-29C257G4 Moving contact * - 3 29C257G5 Moving contact *7 2 2 42A250 Spring (outside poles) Description *7A 29C2SOP5 Spring clip (center pole) s 2 2 29C277P9 Barrier SA 29C277P0 Barrier, complete (includes Ref. Nos. S and SA) 9.29C277Gl Cross bar assembly 0 3 3 29C25SG3 Pivot * 3 3 29C2SOPS Spring (back of pivot) 2-3 29C25SG Lower stud assembly (not used on AK-3 or AK-3A) 2 3-29C25SG2 Lower stud assembly 3 2 2 23C52P Insulation (under lower stud) 4 2 2 29C2SOP7 Support (outside) 5 2 2 29C2SOP Support (intermediate) 3 3 29B2SSG Arc quencher 7-2C754G2 Arc quencher clamp AK -3 or 3A only 7 29C273G2 Arc quencher clamp (sand gray) AK-2 or 2A S 2 2 29C2SOP4 Stud, arc quencher clamp tl9 2 2 77L25P29 Insulation for Ref. No. S t20 2 2 393A993P9 Stop nut for Ref. No. S *2 2 42A2S Stationary contact spring 2A 3 3 42A20S Movable contact spring 2B 29C277Pll Spring clip t22 29C2SOP Moving contact pivot pin (center pole) 23 2 2 29C2SOP2 Moving contact pivot pin (outside poles) *24 042A0290 Spring 25 22C52G omagnet and armature assembly 2 See table B oclo sing coil 27 3 3 See note below Overcurrent trip device 2S 3SA3P Clamp for EC -2 trip device 2S 3 3 555445P Clamp for EC- trip device 29-29C2SP5 Retaining ring 29-29C2SlP Retaining ring 30 3 - S45C27G2 Primary disconnect assembly 30-3 S45C27G4 Primary disconnect assembly 30A 42A222 Spring 3 2 2 29C2SP3 Retainer *32 24 24 453A00P2 Contact finger 33-453A29P Retainer 33-453A29P2 Retainer 34 457ASP4 Spacer 35 --- -- -- - - Screw, hex. hd, /4 in. -20 by 3 /2 in. * Recommended for stock for normal maintenance. t Not shown. ** See breaker nameplate for frame size. 5 Electrically operated breakers Note for overcurrent trip devices: () No parts furnished for field installation on EC- trip devices. GEF-449G (2) Only part furnished for field installation on EC-2 or EC-2A trip devices is plastic cover, Cat. No. 242C45Pl. (3) When replacement trip devices are ordered, it is imperative that order includes complete nameplate reading of the breaker or breakers involved and, if a contemplated ampere rating change is involved, the order should also include information as to ampere rating, time-current characteristic, and instantaneous trip setting desired. Note for operating mechanisms: () Individual parts cannot be furnished for operating mechanisms. (2) When replacement is necessary give complete nameplate reading when ordering. 3

GEF-449G Quantity Required Ref. for 3-pole Breaker No. Frame Size 225 Amp** 00 Amp** 3 37 38 38 39 t39a t40 4 42 43 t43a 44 44 44 t44 t44 t44 45 4 4 47 *48 t49 A* 50 A* 5 TA52 TA*52A TA*52B TA52C A*53 A 54 A 55 *5 57 57 *58 59 *t0 2 2 3 4 4 4 5 7 7 8 8 9 4 maximum 4 maximum 3 3 3 Catalog Number 38All0G2 22C505G 432A7G2 432A7G5 29C28P 29C28P2 42A33 22C502G 22C529G 0C789G 0C789G2 259C07G 259C07P0 259C07G2 259C07G3 259C07Pll 259C07G4 259C08G 27B9P 9D807P 48A2238 295B445P22 295B445P222 295B445P223 B797P22 B797P223 llb797p222 22C50P 22C50P2 29C282G2 29C282G5 t t 72594 29C299G2 293908G275 293908G274 84C85G 3493P 3493P2 3493P3 295B475P2 394Al44P 275B995P 95C3P 394A0P 457A73G 29C27G2 * Recommended for stock for normal maintenance. ** See breaker nameplate for frame size. t Not shown. Description Movable secondary disconnects (drawout breaker) Cutoff switch (electrically operated breaker) Auxiliary switch, 2 stages Auxiliary switch, 5 stages Manual trip button Trip label Spring for manual trip button Shunt trip device with coil Closing switch Shaft assembly (Manual Breaker only) order Ref. 43 and 43A together Link assembly Escutcheon, manual breaker (black) Escutcheon, electrically operated breaker (black) Escutcheon, electrically operated breaker (with handle) (black) Escutcheon, manual breaker (blue) Escutcheon, electrically operated breaker (blue) Escutcheon, electrically operated breaker (blue) with pistol grip handle Indicator Handle (black) Handle (gray) "X" relay (see Table A, page ) "Y" relay (see Table A, page ) Return spring, rear of escutcheon Stationary contacts, "X" relay / On early AK -2-5, AK-2-25 and Moving contacts, "X" relay \, AKF-2-25 With.. o suffix number Springs, moving contacts, "X" relay Stationary contacts, "X" relay / Molded moving arm, "X" relay (with moving contacts) \ all others Armature return spring, "X" relay. Operating coil, "X" relay (see Table A, page ) Cover, "X" relay ( On early AK -2-5, AK-2-25 and AKF -2-25 Jumper, "X" relay f with no suffix number Coil for shunt trip device (see Table B, page 7) tinstantaneous undervoltage device, a-c (with coil) tinstantaneous undervoltage device, d-e (with coil) Time -delay undervoltage device, a-c Time -delay undervoltage device, d-e Coil for undervoltage device (see Table B, page 7) Static time delay, a-c or d-e (replaces complete time delay and volt device coil only) Spring, for undervoltage device :t:bell alarm device Terminal board, terminals Terminal board, 0 terminals Link and bushing for auxiliary switch Cover for auxiliary switch, stage Cover for auxiliary switch, 2 stages Cover for auxiliary switch, 5 stages Base for wall mounted, general purpose breaker Angle for wall mounted, general purpose breaker Terminal for wall mounted, general purpose breaker Terminal for wall mounted, general purpose breaker Cable clamp for wall mounted, general purpose breaker Cable clamp for wall mounted, general purpose breaker Maintenance handle t If at any time a breaker is to have added to it either shunt trip, undervoltage device, or bell alarm device, the order for the device must include the following information: () Complete nameplate reading of breaker involved. (2) Desired voltage rating of device, whether a-c or d-e, and if a -c, the frequency. (3) In the case of undervoltage devices, specify whether instantaneous or time delay. A On -, specify Cat. No. of "X" relay when ordering these parts. b. Order by circuit breaker Serial No. 4 www. ElectricalPartManuals. com

C 53 fig. 0. Cutoff switch (ref. 37) 5 50 54 55 fig.. "X" contactor (ref. 47) fig.. Bell alarm device (ref. ) fig. 7. "y" relay (ref. 48) Fig. 2. Termmal board (ref. 2) 5 fig. 8. Shunt trip device (ref. 4) fig. 3. Auxiliary switch (ref. 38) fig. 9.... J! 57 s,'"irj 58 Time delay undervoltage device (ref. 57) fig. 3A.. ElectricalPartManuals. co Static time delay m., 0 m :;a Q :;a n c: =i "' :;a m m :;a "' '>:! I ""... ""

GEF -449G NOTES FOR FIG. 4: Fig. 4. Manual (left) and electrical (right) front frame assemblies for Type AK-2-5 and -25 power circuit breakers (PHOTO 802400) () Should it become necessary to replace the complete front frame of the breaker, it is necessary that the order include complete nameplate reading of existing breaker. (2) f an existing manual breaker is to be converted to electrical operation, the order must include, in addition to Rating complete nameplate reading, a description of desired change and complete voltage and frequency rating of both closing and tripping circuits. TABLE A Catalog Number "X" Relay_ Relay Coil, only Relay Coil, only Complete, Ref. 47 (Ref. 53) Complete, Ref. 47 (Ref. 53) Volts Cycles tor fl. and Early - for Late -, and all -2 Breakers 24 295B445Pl 295B445P20 295B445P2 295B445P202 D-C 25 295B445P3 295B445P203 48 250 295B445P4 295B445P204 5 295B445P7 295B445P207 208 295B445P0 295B445P20 25 230 295B445P3 295B445P23 40 ---------- - ----- ------ - 230 40 295B445P2 295B445P22 5 295B445P 295B445P20 ' 208 "I 208 295B445P9 295B445P209 230 50 295B445Pl2 295B445P22 380 295B445P7 295B445P24 40 295B445P5 295B445P2 295B445P5 295B445P205 295B445P8 295B445P208 0 230 295B445Pll 295B445P2 fl. 40 295B445P4 295B445P25 Original breaker had no suffix numeral or letter. Only complete relay furnished. B797Pl B797P2 B797P3 B797P4 B797P7 B797P0 B797P3 B797P Breakers B797P20 B797P202 B797P203 B797 P204 B797 P207 B797P20 B797P23 B797P2 - - ----- ---- - ------ - ----- - B797P B797P9 B797Pl2 B797P7 B797P5 B797P5 B797P8 B797 Pll B797P4 B797P20 B797P209 B797P22 B797P27 B797P25 B797 P205 B797P208 B797P2 B797P24 "Y" Relay Complete (Ref. 48) 295B444Pl 295B444P2 295B444P3 295B444P4 295B444P7 295B444Pl0 295B444P3 --- --- -- - -- 295B444Pll 295B444P5 295B444P8 295B444Pll 295B444Pl7 295B444P4 295B444P5 295B444P8 295B444Pll 295B444P4

Fig 5. Accessories for wall mounting (ref. 5,, 7, 8) Volts Rating Cycles Closing Solenoid Coil (Ref. 2) 24 --- 48 3A77307 D-C 25 3A77303 250 3A77305 5 3A77303 208 3A7730 230 3A773G4 40 3A7730 575 3A77302 25 5 3A77302 208 3A77303 230 3A77305 50 380 3A7730 40 3A77308 3A77300 575 5 3A7730 208 3A77303 230 0 3A77304 40 3A77307 575 3A77309 TABLE B (PHOTO 80258) Fig.. Maintenance handle for electrically operated breakers not equipped with manual handles (ref. 9) Catalog Number Undervoltage Device Coil (Ref. 58) Shunt Trip Instantaneous Device or Old Design Coil Oil Dashpot Type Static Time (Ref. 5) Time Delay Delay Type 27508055 2750805 27508028 2750809 27508029 2750808 275080h 27508030 2750809 275080597 2750802 2750802 27508029 2750800 27508029 2750800 2750807 2750807 2750805 2750802 2750805 2750804 2750802 2750802 2750802 2750802 27508027 2750803 2750804 2750803 27508029 2750808 27508025 2750802 2750802 27508027 2750802 2750807 275080597 27508027 2750803 2750807 27508020 Tinput voltage to static timing unit (Fig. 3A) indicated. OEF-4490 7

GEF-449G Without ground trip Fig. 7. Magnetic coil assembly Magnetic Sensor Coils - Assem bly (Fig 7) With ground trip Poles Rating Cat. No. Poles Rating Grd. Trip Range Cat. No. 8 www 2 45/225 07D7554G2 2 45/225 00/400 07D7554G 3 45/225 07D7554G3 3 45/225 00/400 07D7554G7 2 200/00 07D7554G4 2 200/00 00/400 07D7554G8 3 200/00 07D7554G5 3 200/00 00/400 07D7554G9 2 200/00 300/200 07D7554G0 3 200/00 300/200 07D7554Gll Fig. 8. Power supply unit Power Supply Units - Cat. No. 5C4508G0 Fig. 9. Power sensor unit. ElectricalPartManuals. com

With Ground Fault Protection 00 to 400 Amp Range Power Sensor Unit AK-25 (Fig. 9) With Instantaneous Trip With Instantaneous Trip Without Instantaneous 4 to 2X Range 4 to 2X Range Trip Without Short Time Delay 84L373G57 84L373G78 - --- With Short Time Delay 2 to 5X Range 84L373G5 84L373G 84L373G0 4 to OX Range 84L373G54 84L373G9 84L373G3 Without Ground Fault Protection Without Short Time Delay 84L373G43 84L373G50 With Short Time Delay 2 to 5X Range 84L373G4 84L373G4 84L373G44 4 to lox Range 84L373G42 84L373G47 84L373G45 Fig. 20. Magnet trip device with mounting bracket Magnet Trip Device with Mounting Bracket - Cat. No. 084C0882 G4 Fig. 2. Ground sensor coil with neutral mounting Fig. 22. Power sensor kit Fourth Wire Grid Sensor Coils 00/400 Cat. No. 52C928Gl 300/200 Cat. No. 52C928G2 ---- GEF-449G With Long Time Delay Without Long Time With Long Time Delay Without Long 80 to 30% Range Delay 80 to 30% Range Time Delay Power Sensor Test Kit- Cat. No. Without Instantaneous Trip - --- 84L373G72 84L373G75 ---- 84L373G48 84L373G49 002D252 GlO 9

GEF-449G 24 OUTS I DE POLE CONTACTS AND BARRIER 25 2 '----08 CE NTER POLE AND FIELD SWITCH MECH. 00 ---.. 0 09---" 0----J Ill 2 ---.../ 3 ---/ I I 4 ---/ 5 ----" Fig. 2'3. Field switch mechanism and contact assemblies r---i""""c'r--- tttt== l7 NOTE: Parts listed below apply only to Types AKF-2-25 and AKF-2A-25. All other parts are identical to those used on Type AK-2-25. Ref. Qty. Per No. Center Pole Catalog No. Description 00 073-08C997P9 Insulation *0 08C998Gl Moving contact 02 2 08C995P2 Link 03 4 394A33P8 Retaining ring 04 08C995P9 Pin 05 2 48A2279Pl Adjustable bushing 0 2 377A87P2 Bearing 07 08C995P0 Cam follower 08 08C99G Crossbar 09 08C995G3 Cam assembly, left 09 08C995G4 Cam assembly, right 0 08C995P Pivot 08C994P8 Lower stud insulation 2 08C995P3 Connector 3 2 394A33P9 Retaining ring *Recommended for stock for normal maintenance. 0 tnot shown. Ref. Qty. Per No. Center Pole Catalog No. Description 4 073-42A404P3 Pin 5 l08c994p7 Lower pivot * 29C257Gl stationary contact * 29C257G2 Stationary contact 7 2 42A28 stationary contact spring 8 29C283G4 Upper stud 9 08C997Pll Contact spacer right side 9 08C997P2 Contact spacer left side 20 29C280Pl Moving contact pivot pin 2 08C998P4 Spacer 22 29C258G3 Lower stud tl23 293B288Gl Arc quencher 24 08C997G3 Insulation *25 08C998G2 Moving contact 2 2 08C994P5 Spring 20 2 22

MEMORANDUM

2-80 (3M) GENERAL ELECTRIC CO. DISTRIBUTION EQUIPMENT 0 IV IS ION PLAINVILLE, CONN. 002 GENERAL fj ELECTRIC