AMB SERIES AMB PRODUCT SPEC. Fast Electrically Actuated Valves PRECISION GOBE CONTROL VALVES SIZES: 1/2 TO 2 INCHES

Similar documents
PS AMA F (a) 0411 ( )

FAIL-SAFE CONTROL VALVE FOR MODULATING CONTROL OF INSTANTANEOUS WATER HEATER & HEAT EXCHANGER APPLICATIONS SERIES MODELS

58OO SERIES 5800 PRODUCT SPEC PNEUMATIC ACTUATED INDUSTRIAL VALVES COMPACT GLOBE CONTROL VALVES SIZES: 1/2 TO 4 INCHES PRODUCT SPECIFICATION

28OO ILEA SERIES 2800 E PRODUCT SPEC INDUSTRIAL LINEAR ELECTRICALLY ACTUATED THREADED BODY, GENERAL PURPOSE, GLOBE CONTROL VALVES

PRECISION FAIL-SAFE LOCK-UP SPEED. breeds:

Product Specification

29OO SIZES: 2-1/2 TO 10 INCHES

FAIL-SAFE CONTROL VALVE FOR MODULATING CONTROL OF INSTANTANEOUS WATER HEATER & HEAT EXCHANGER APPLICATIONS. ARA - 3-Way,Flanged Steel Mix Valves;

PNEUMATIC ACTUATED INDUSTRIAL VALVES SERIES:

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

ELECTRICALLY ACTUATED DOUBLE SEATED IRON - 1 1/2-2

Product Specification

PYTHON 1500 SERIES CONTROL VALVES. Pneumatic and Electric Actuated

PYTHON 1500 SERIES CONTROL VALVES. Pneumatic and Electric Actuated

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Installation, Operation & Maintenance Instructions

3-WAY MIXING, BRONZE BODY

Features Globe Valve 2-Way & 3-Way Assembly Features:

AMURACT ACTUATORS LS & LE LINKAGES with F3, F4, F5, & F6 MOTORS Installation Operation and Maintenance Instructions AMURACT IOM TABLE OF CONTENTS

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

FAIL-SAFE CONTROL VALVES. Fast Electrically Actuated Control Valves

Python 1500 Series Control Valves. Pneumatic and Electric Actuators PYTHON

GVI Series Industrial Globe Valves for Flow Control

DBOY Series Pneumatic Control Valve

SINGLESEAT BRONZEBODY

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

PNEUMATIC AND ELECTRIC ACTUATED INDUSTRIAL VALVES SERIES:

Python Series Control Valves

3-way 1/2-2 Globe Valves

High Pressure 2-way 2 1/2-6 Globe Valves

Pressure Independent Control Valve

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

Python Series Control Valves

NV Direct Coupled Globe Valve Actuator

Electric Actuator Instructions

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure

BOSS Series D Control Valve

Electronic Ball Valve Guide Specifications

Selection Guide. Vx-2x13-5xx-9-xx Series Vx-2x13-8xx-9-xx Series VB-2x xx Series. Schneider Electric Ball Valve Assemblies

GE Oil & Gas. Becker * and Series V-0 Control Valves

COMMERCIAL. Product PRofile

Flowrite VF 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Flowrite 599 Series Two-Way Valves 1/2 to 2-inch Bronze Body

VE VVG Series Electronic Two-way Valves Normally Closed

Distributed By: M&M Control Service, Inc

Control Valves & Regulators

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

General Stem-Guided Control Valves

SERIES 58OO 5800 IOM. Installation Instructions & Maintenance Document COMPACT GLOBE CONTROL VALVES TABLE OF CONTENTS PRODUCT OVERVIEW

INTRODUCTION BODY SUB-ASSEMBLY (FIGURE 1) 2 G X L GLOBE CONTROL VALVE VALTEK SULAMERICANA. Top entry assembly: quick and easy maintenance

General Stem-Guided Control Valves

NETSIAN TECHNOLOGY VALVE SCHEDULE

Compact Electric Actuated Ball Valves PVC Body, Teflon/EPDM Seals 1/2 to 1 inch Pipe

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

SERIES 830T THREE WAY VALVE

Electric Top-Guided Single-Seated Control Valves

Electronic Globe Valve Guide Specifications

DBO(Y)(S)-3 CONTROL VALVE SIZES 2" 8" ANSI CLASS 125/250, 150/300, 600

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

CONTROL VALVES QUALITY, DEPENDABILITY, SERVICE. REPUTATION BUILT ON. Innovative Solutions

Mark 33 Series. Control Valves Mark 33/39 Electric Motor Control Valves. Electric Motor Control Valves. Features. CRN Registration Number Available

Zone Valves and Parts (Honeywell)

SMAR RIM CAGE GUIDED CONTROL VALVES. Always in control of flow. Previously manufactured by Dezurik and Honeywell

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

KOMBAT K1 Pneumatic Control Valve

Control Valves for General Applications

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

Self-Operating Temperature Regulators

TECHNICAL INSTRUCTIONS Heavy Duty Bronze Series

Control Valve Technical Brochure

VG7000 Female Threaded Cast Bronze Valve Series with Electric Actuators

Baumann NV Electric Actuator with Control Valves

Electronic Globe Valves

OVERVIEW & SECTION GUIDE

599 Series Zone Valve Bodies:

PNEUMATIC ON OFF GLOBE VALVE

Baumann Series Sanitary Regulators

Electric Actuated 3-Way Ball Valves L-Port, PVC Body, Teflon/EPDM Seals 1/2 to 2 inch Pipe

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

Direct or Reverse-Acting?

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

AEL6 Series Smart Electric Actuators for ½" to 4" Control Valves

Powermite 599 Series MT Series Terminal Unit Three-way Valves

Flowrite Globe. Pneumatic 4-inch Valve Actuator. Valves. Description. Applications. Features D-141.

VG7000 Series Bronze Control Valves

Control valves with pneumatic actuators up to 350 C PN

Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007

2-Way & 3-Way Non Spring Return Characterized Ball Valves

Powermite 599 Series MT Series Terminal Unit Two-way Valves

Model 5400 / 5450 Control Valve

VG8000N Series PN16, DN15 - DN150

VE411 & 431 SERIES ELECTRONIC SYSTEM CONTROL VALVES Universal two way, or three way mixing globe valves - 25mm to 100mm (1 to 4 )

VE411 & 431 SERIES ELECTRONIC SYSTEM CONTROL VALVES Universal two way, or three way mixing globe valves - 25mm to 100mm (1 to 4 )

Compact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT

Specification: Industrial Mixing Center

Transcription:

Fast Electrically Actuated Valves PRECISION GOBE CONTROL VALVES SERIES AMB SIZES: 1/2 TO 2 INCHES Two-Way and Three-Way, Linear, Steel, Bronze, or Stainless Steel Body Valves for the Process and Utility Applications AMURACT_PS_AMB_RevG_0418 AMB PRODUCT SPEC 2600 EMRICK BLVD BETHLEHEM, PA 196%20 USA 96%0-922-0096% WWW.WARRENCONTROLS.COM DEPENDABLE, RUGGED, PRECISION CONTROL VALVES AND ACCESSORIES

TABLE OF CONTENTS Body Style Versus Application...4 Coefficients (Cv) Versus Travel...5-6 Sizing Reference and Load Sizing Calculations...7 Shut-Off P Ratings...8 Actuator Specifications...9 Factory Default Settings...9 Actuator Orientations... 10-12 Dimensions and Weights... 13-14 Heat/Sound Pressure Level Guidelines... 15-16 Typical Construction... 17-20 Configurations... 21-22 Type 20 Two-Way Single Seat Unbalanced Valve Flexible Design Options provide optimum performance and extended reliability in a cost effective, application specific package. Dual Point PEEK Bearing Stem Guiding provides both stability and low friction, yielding reduced hysteresis and optimum control. Trim available in 316SS, 17-4 ph, Alloy 6, and PEEK. Port Guided Plug Assembly provides stability and desired equal percentage flow characteristic. Lower Plug offers easy access for inspection and clean out. Rugged Body with a selection of port reductions. 1 2600 Emrick Blvd Bethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com AMB_PS_RevG_0418

AMURACT OVERVIEW The AmurAct Actuator is a revolutionary product in both function and design with best-in-class performance at a price point previously ignored by other manufacturers. While when configured the valve can fully open from closed in about 8 seconds, the actual response time to a required heavy load change from a normal flow condition is only 2 3 seconds, on par with pneumatically actuated products. The AmurAct linkage has tremendous torque as it approaches closure allowing for increased close off pressure even on larger valves. Under close off, the AmurAct linkage is in FULL LOCK-UP mode that allows removal of the motor for service or replacement quite easily with limited disassembly.** Fail- Safe is of course included with Enerdive*. The patented Enerdrive System. The modern, electronic replacement for antiquated spring return actuator is a super capacitive fail-safe return system. * Enerdrive or the Enerdrive System is both a patent and trademark of National Environmental Products, Ltd. Since its introduction, Enerdrive has proven its versatility and dependability. As a system that is fully incorporated into the PC board for both low and line voltage service, the power generated and stored in its capacitors will drive the control valve at full rated torque to its safety position. It is 100% operational with the resumption of power. Each unit may be manually positioned with the clutch override that is standard on each actuator. Most importantly, the final fail position, either normally open or normally closed may be chosen at any time either before or after installation with the flick of a dip switch. ** Two-way Valves Only. Corrosion-resistant stainless steel safety enclosure. Base and linkage also constructed from corrosionresistant stainless steel. Strong, long-life sintered bronze pre-lubricated bearings at pivot points....the actual response time to a required heavy load change from a normal flow condition is ONLY 2 3 SECONDS! Articulated stem connection to extend valve packing life. Geometric locking for failsafe closure without sustained actuator force, allowing for safe, in-line motor replacement.** Strong and compact... a single actuation package fits and operates a wide selection of valves. Laboratory & field tested for strength and durability. Optional configuration for higher-temperature applications AmurAct Fast Electric Actuator Series AMURACT AMB_PS_RevG_0418 2

SERIES: AMB Precision Globe Control Valves Upper Port Common Port Upper Port Lower Port Lower Port Type 30 Three-Way Mixing Valve Common Port Type 32 Three-Way Diverting/ Mixing Valve Type 28 Two-Way Single Seat Low Unbalanced Valve Long-Life Multi-Stack EPDM Lip Packing Guided Low-Friction PTFE V-Ring Packing Spring Loaded Fluoraz O-Ring Upper and Lower Body Seals in Stainless Steel Body Valves Long-Life Multi-Stack EPDM Lip Packing EPDM (ethelene propylene diene monomer (M-class) rubber), Lip Style packing is best suited for Water or Water/Glycol Services and may also be used with low pressure steam. EPDM Lip Packing is not suitable with oils, hydrocarbons or acids. Guided Low-Friction PTFE V-Ring Packing, Spring Loaded PTFE (Polytetrafluoroethylene, a thermoplastic polymer) packing its V-Ring configuration is the best type of general service packing for non-water services and offers the lowest friction of all packing types, allowing for the best control of the valve under operation. PTFE is best used on steam service and all other gases and liquids that do not contain alkali metals or fluorinating agents. Description: Warren Controls Precision Globe Control Valves feature rugged bronze or stainless steel bodies with a variety of trim materials and port sizes. The equal percentage and linear plugs in the 2-way valves and linear plugs in the 3-way valves provide excellent modulating control of a wide variety of fluids for pressure, temperature, level, and flow applications from -20 to 450ºF. The AMB Series is ideally suited where value and long life are important objectives for applications including but not limited to the Chemical, Food & Beverage, General Service, Refining, District Energy, and Pharmaceutical Industries. 3 2600 Emrick Blvd Bethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com AMB_PS_RevG_0418

BODY STYLE VERSUS APPLICATION 2-WAY VALVES (Control of Liquids, Gases, and Steam) Type 20 2-Way Single Seat Unbalanced Valve The most commonly applied solution with ANSI Class IV and VI leakage rates. See Table on page 21 for Fluid Temperature Limits Sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, 2 inch Body: ANSI B16.15 Bronze 250LB Threaded (NPT), or 316 Stainless Steel 300LB Threaded (NPT), or 316 Stainless Steel 300LB SCH 40 Buttweld (BWE) Stainless Steel body valves contain Fluoraz 797 O-Ring upper and lower body seals.* Trim: EQ% or Linear, 316 Stainless Steel, Alloy 6, PEEK, or 17-4 ph Hardened Stainless Steel Leakage Rates: ANSI Class IV (Stainless Steel and Alloy 6 Trim), ANSI Class VI (PEEK Trim) Packing: Long-Life Multi-Stack EPDM Lip Packing Guided Low-Friction PTFE V-Ring, Spring Loaded Packing Rangeability: 50:1 3-WAY VALVES (Control of Liquids) Type 30 3-Way Mixing Valve This valve has two inlets and one outlet, and is the simplest solution for mixing or bypass applications with an ANSI Class IV leakage rate. In normal applications the inlet pressures are near equal and control is possible from 5% to 95% of travel with inlet pressures up to 100 PSI. See Table on page 21 for Fluid Temperature Limits Sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, 2 inch Body: ANSI B16.15 Bronze 250LB Threaded (NPT), or 316 Stainless Steel 300LB Threaded (NPT), or 316 Stainless Steel 300LB SCH 40 Buttweld (BWE) Stainless Steel body valves contain Fluoraz 797 O-Ring upper and lower body seals.* Trim: Linear, 316 Stainless Steel Packing: Long-Life Multi-Stack EPDM Lip Packing (EPDM Lip Packing is not suitable for use with oils, hydrocarbons, or acids.) Guided Low-Friction TFE V-Ring, Spring Loaded Packing Rangeability: 50:1 Stem Down Stem Up Stem Down Stem Up Upper Port Common Port Upper Port Common Por The valve closes The valve opens Lower Port The upper port opens and the lower port closes Lower Port The upper port closes and the lower port opens Type 28 2-Way Single Seat Low Unbalanced Valve Low Trim with ANSI Class IV and VI leakage rates. See Table on page 21 for Fluid Temperature Limits Sizes: 1/2, 3/4, 1 inch Body: ANSI B16.15 Bronze 250LB Threaded (NPT), 316 Stainless Steel 300LB Threaded (NPT), or 316 Stainless Steel 300LB SCH 40 Buttweld (BWE) Stainless Steel body valves contain Fluoraz 797 O-Ring upper and lower body seals.* Trim: Modified Linear, 316 Stainless Steel, or PEEK Leakage Rates: ANSI Class IV (Stainless Steel Trim), ANSI Class VI (PEEK Trim) Packing: Long-Life Multi-Stack EPDM Lip Packing Guided Low-Friction PTFE V-Ring, Spring Loaded Packing Rangeability: 40:1 for Cv 1.00 and 0.50 20:1 for Cv 0.25 Type 32 3-Way Diverting/Mixing Valve Designed as a diverting valve with one inlet and two outlets with ANSI Class III leakage rate. However, flow can be reversed for mixing if this port configuration is desirable. The difference between the upper port and lower port pressure must not exceed 50 PSID. See Table on page 21 for Fluid Temperature Limits (See Piping Note on Page 8) Sizes: 1, 1-1/2, 2 inch Body: ANSI B16.15 Bronze 250LB Threaded (NPT), or 316 Stainless Steel 300LB Threaded (NPT), or 316 Stainless Steel 300LB SCH 40 Buttweld (BWE) Stainless Steel body valves contain Fluoraz 797 O-Ring upper and lower body seals.* Trim: Linear, Bronze (Bronze 250LB Threaded), or 316 Stainless Steel (316 Stainless Steel 300LB Threaded or Buttweld) Packing: Long-Life Multi-Stack EPDM Lip Packing Guided Low-Friction PTFE V-Ring, Spring Loaded Packing O-Ring: EPR (Bronze 250LB Threaded), Fluoraz 797 (316 Stainless Steel 300LB Threaded or Buttweld)* Rangeability: 50:1 Stem Down Stem Up Stem Down Stem Up The valve closes The valve opens Upper Port Lower Port Upper Port Lower Port *Note: Fluoraz o-ring is not compatible with the following solvents: acetates, acetone, benzene, carbon tetrachloride, ethers, Freons, ketones, lacquers, methyl ethyl ketone, and toluene - Consult Factory with service conditions for alternate o-ring selection. Common Port The upper port opens and the lower port closes Common Port The upper port closes and the lower port opens Series AMURACT AMB_PS_RevG_0418 4

FLOW COEFFICIENTS (Cv) VERSUS TRAVEL 2-WAY VALVES (Control of Liquids, Gases, and Steam) Valve Size (IN) VALVE Trim Style 1/2 EQ% 3/4 1 1-1/4 1-1/2 2 Valve Size (IN) Trim %Travel Size Port (IN) Size 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0.876 FULL 4.90 4.78 3.53 2.57 1.92 1.20 0.95 0.69 0.43 0.17 0.876 1SR 3.20 3.16 2.29 1.61 1.19 0.75 0.51 0.39 0.26 0.13 0.626 2SR 1.50 1.44 0.96 0.72 0.52 0.42 0.31 0.21 0.10 0.06 LINEAR 0.876 FULL 6.00 5.40 4.80 4.20 3.60 3.00 2.40 1.80 1.20 0.60 0.876 FULL 7.20 7.09 5.53 3.51 2.53 1.73 1.24 0.88 0.52 0.27 EQ% 0.876 1SR 5.50 5.31 3.73 2.64 1.95 1.21 0.96 0.70 0.43 0.17 0.876 2SR 3.30 3.30 2.34 1.63 1.20 0.75 0.51 0.39 0.26 0.13 0.626 3SR 1.50 1.45 0.96 0.73 0.52 0.42 0.31 0.21 0.10 0.06 LINEAR 0.876 FULL 7.20 6.48 5.76 5.04 4.32 3.60 2.88 2.16 1.44 0.72 1.126 FULL 10.0 9.70 6.52 4.40 2.82 2.04 1.36 0.81 0.55 0.30 0.876 1SR 8.60 8.38 6.09 3.64 2.58 1.74 1.25 0.89 0.52 0.27 EQ% 0.876 2SR 6.00 5.79 3.88 2.70 1.97 1.22 0.96 0.70 0.43 0.17 0.876 3SR 3.40 3.41 2.38 1.64 1.20 0.75 0.51 0.39 0.26 0.13 0.626 4SR 1.50 1.46 0.97 0.73 0.53 0.42 0.31 0.21 0.10 0.06 LINEAR 1.126 FULL 10.0 9.00 8.00 7.00 6.00 5.00 4.00 3.00 2.00 1.00 1.438 FULL 16.0 15.5 10.4 7.04 4.51 3.26 2.18 1.30 0.88 0.48 1.126 1SR 10.0 9.70 6.52 4.40 2.82 2.04 1.36 0.81 0.55 0.30 EQ% 0.876 2SR 8.60 8.38 6.09 3.64 2.58 1.74 1.25 0.89 0.52 0.27 0.876 3SR 6.00 5.79 3.88 2.70 1.97 1.22 0.96 0.70 0.43 0.17 0.876 4SR 3.40 3.41 2.38 1.64 1.20 0.75 0.51 0.39 0.26 0.13 LINEAR 1.676 FULL 17.2 15.5 13.8 12.0 10.3 8.60 6.88 5.16 3.44 1.72 1.676 FULL 24.0 22.5 19.7 15.1 10.3 7.30 4.90 3.20 1.90 0.90 1.438 1SR 16.0 15.5 10.4 7.04 4.51 3.26 2.18 1.30 0.88 0.48 EQ% 1.126 2SR 10.0 9.70 6.52 4.40 2.82 2.04 1.36 0.81 0.55 0.30 0.876 3SR 8.60 8.38 6.09 3.64 2.58 1.74 1.25 0.89 0.52 0.27 0.876 4SR 6.00 5.79 3.88 2.70 1.97 1.22 0.96 0.70 0.43 0.17 LINEAR 1.676 FULL 18.0 16.2 14.4 12.6 10.8 9.00 7.20 5.40 3.60 1.80 2.126 FULL 40.0 37.1 33.1 27.3 19.8 13.2 8.50 5.30 2.80 1.10 1.676 1SR 24.0 22.5 19.7 15.1 10.3 7.30 4.90 3.20 1.90 0.90 EQ% 1.438 2SR 16.0 15.5 10.4 7.04 4.51 3.26 2.18 1.30 0.88 0.48 1.126 3SR 10.0 9.70 6.52 4.40 2.82 2.04 1.36 0.81 0.55 0.30 0.876 4SR 8.60 8.38 6.09 3.64 2.58 1.74 1.25 0.89 0.52 0.27 LINEAR 2.126 FULL 37.0 33.3 29.6 25.9 22.2 18.5 14.8 11.1 7.40 3.70 VALVE Trim Style 1/2 MODIFIED LINEAR 3/4 1 MODIFIED LINEAR MODIFIED LINEAR AGENCY APPROVALS Type 20 Type 28 FLOW COEFFICIENTS (Cv) 2-Way Single Seat Unbalanced Valve FLOW COEFFICIENTS (Cv) 2-Way Single Seat Low Unbalanced Valve Trim %Travel Size Port (IN) Size 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% FULL 1.00 0.85 0.72 0.58 0.47 0.36 0.26 0.17 0.10 0.05 0.250 1SR 0.50 0.43 0.36 0.29 0.23 0.18 0.13 0.09 0.05 0.03 2SR 0.25 0.21 0.18 0.15 0.12 0.09 0.07 0.04 0.03 0.01 0.250 FULL 1.00 0.85 0.72 0.58 0.47 0.36 0.26 0.17 0.10 0.05 1SR 0.50 0.43 0.36 0.29 0.23 0.18 0.13 0.09 0.05 0.03 2SR 0.25 0.21 0.18 0.15 0.12 0.09 0.07 0.04 0.03 0.01 0.250 FULL 1.00 0.85 0.72 0.58 0.47 0.36 0.26 0.17 0.10 0.05 1SR 0.50 0.43 0.36 0.29 0.23 0.18 0.13 0.09 0.05 0.03 2SR 0.25 0.21 0.18 0.15 0.12 0.09 0.07 0.04 0.03 0.01 FLOWING DIFFERENTIAL TRIM MATERIALS PRESSURE LIMIT Bronze 50 PSID 316 Stainless Steel 100 PSID PEEK 100 PSID 17-4 ph Hardened Steel 200 PSID Alloy 6 300 PSID % CV Type 20 100 90 80 70 60 50 40 30 20 10 0 TYPICAL FLOW CURVES 100 90 80 70 60 50 40 30 20 10 0 % TRAVEL Type 28 Pressure ratings are PSIG For applications below 32º F consult factory. For applications above 375º F, 300 THD Stainless Steel Body is recommended. BODY PRESSURE- TEMPERATURE RATINGS: Temp. (F) 250 THD 300 THD& Bronze BWE SS -20 To 100 400 720 150 400 670 175 392 645 200 385 620 225 375 605 250 365 590 275 350 575 300 335 560 325 317 548 350 300 537 375 275 526 400 250 515 450-497 500-480 LINEAR EQUAL% 5 2600 Emrick Blvd Bethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com AMB_PS_RevG_0418

FLOW COEFFICIENTS (Cv) VERSUS TRAVEL % CV % CV Type 30 110 100 90 80 70 60 50 40 30 20 10 0 120 110 100 90 80 70 60 50 40 30 20 10 0 TYPICAL FLOW CURVE 0 10 20 30 40 50 60 70 80 90 100 % TRAVEL 2832 TYPICAL FLOW CURVE 0 10 20 30 40 50 60 70 80 90 100 % TRAVEL UPPER LOWER COMBINED Type 32 Diverting UPPER LOWER COMBINED 3-Way Valves (Control of Liquids) Valve Size (IN) VALVE Trim Style 1/2 LINEAR 3/4 LINEAR 1 LINEAR VALVE Type 30 Travel Travel Trim Size (IN) Port Size 100% Valve Size(IN) Trim Style Trim Size (IN) Port Size 100% 1.126 FULL 6.30 1.676 FULL 18.5 1-1/4 LINEAR 0.876 1SR 4.00 1.126 1SR 10.0 0.626 2SR 2.00 1.676 FULL 20.0 1-1/2 LINEAR 0.626 3SR 1.00 1.126 1SR 10.0 1.126 FULL 8.20 2.126 FULL 40.0 2 LINEAR 0.876 1SR 4.00 1.676 1SR 20.0 0.626 2SR 2.00 0.626 3SR 1.00 1.126 FULL 10.0 0.876 1SR 4.00 0.626 2SR 2.00 0.626 3SR 1.00 Valve Travel 100% Size (IN) Trim Style Upper Lower 1 LINEAR 12 15 1-1/2 LINEAR 22 26 2 LINEAR 40 47 FLOW COEFFICIENTS (Cv) 3-Way Mixing Valve FLOW COEFFICIENTS (Cv) Type 32 3-Way Diverting/Mixing Valve Series AMURACT AMB_PS_RevG_0418 6

SIZING REFERENCE & LOAD SIZING CALCULATIONS STEAM TABLE Steam Pressure PSIG Temp. ºF Temp. ºC Sensible Heat BTU/Lb. Latent Heat BTU/Lb. Total Heat BTU/Lb. 0 212 100 180 971 1151 10 239 115 207 952 1159 25 266 130 236 934 1170 50 297 147 267 912 1179 75 320 160 290 896 1186 100 338 170 309 881 1190 125 353 178 325 868 1193 150 365 185 339 858 1197 200 387 197 362 838 1200 250 406 208 381 821 1202 300 422 217 399 805 1204 400 448 231 438 778 1216 500 470 243 453 752 1205 600 489 254 475 729 1204 Rectangular Tank Capacity in Gallons Height x Width x Length (inches) Gallons = 230 or Gallons = H x W x L (Ft.) x 7.5 Circular Tank Storage Capacity in Gallons Storage = 6D 2 x L (Gallons) Where: D = Tank Diameter in Feet L = Length in Feet Heating Water with Steam Quick Method GPM Lbs./Hr. = x T 2 Accurate Method GPM x 500 x T Lbs./Hr. = h fg Heating or Cooling Water with Water GPM 1 = F water 2 temp. rise or drop GPM 2 x F water1 temp. rise or drop Heating or Cooling Water BTU / Hr. GPM = ( F water temp. rise or drop ) x 500 Heating Oil with Steam GPM Lbs./Hr. = x ( F oil temp. rise) 4 Conversion Factors 1 Lb. Steam / Hr. = 1000 BTU / Hr. 1 Cubic Meter = 264 U.S. Gallons 1 Cubic Foot Water = 62.4 Lbs. 1 PSI = 2.04 Inches of Mercury 1 PSI = 2.3 Feet of Water 1 PSI = 27.7 Inches of Water 1 U.S. Gallon Water = 231 Cubic Inches 1 U.S. Gallon Water = 8.33 Lbs. Heating Air with Water CFM x ( F air temp. rise) GPM = 2.16 x 1000 x ( F water temp. drop) Heating Liquids with Steam GPM x 60 x Cp x W Lbs./Hr. = x T h fg Heating Liquids in Steam Jacketed Kettles Gallons x Cp x S x 8.33 Lbs./Hr. = x T h fg x t General Liquid Heating W x Cp Lbs./Hr. = h fg x t x T Heating Air with Steam CFM Lbs./Hr. = x T 900 Glossary of Terms t = Time in Hours Cp = Specific Heat of Liquid S = Specific Gravity of Fluid W = Weight in Lbs. T = Temperature Rise or Fall in F hf g = Latent Heat of Steam 7 2600 Emrick Blvd Bethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com AMB_PS_RevG_0418

SHUT-OFF P RATINGS AMB SERIES Type 30 AMB Shut-Off P Ratings LOWER SEAT SHUTOFF MOTOR CHOICES UPPER SEAT SHUTOFF MOTOR CHOICES SIZES SEAT DIAMETER F3 & F5 F4 & F6 F3 & F5 F4 & F6 1/2-1 0.626 220 708 237 720 1/2-1 0.876 113 361 95 345 1/2-1 1/2 1.126 68 219 42 193 1 1/4-2 1.676 31 99 11 86 2 2.126 61 46 AMB SERIES Type 32 AMB SERIES Type 20 SHUTOFF MOTOR CHOICES SIZES SEAT DIAMETER F3 & F5 F4 & F6 1/2-1 1/4 0.626 250 400 1/2-2 0.876 150 300 1-2 1.126 100 175 1 1/4-2 1.483 65 125 1 1/2-2 1.676 50 100 2 2.126 30 60 AMB SERIES Type 28 SHUTOFF MOTOR CHOICES SIZES F3 & F5 F4 & F6 1/2 720 -- 3/4 720 -- 1 720 -- LOWER SEAT SHUTOFF MOTOR CHOICES UPPER SEAT SHUTOFF MOTOR CHOICES SIZES F3 & F5 F4 & F6 F3 & F5 F4 & F6 1 150 300 150 300 1 1/2 -- 250 -- 250 2 -- 200 -- 200 NOTES: 1. (TYPE 30 and 32) The two output ports must not have more than 100 PSI differential between them. Type 30 Three-Way Mixing Valve 2. (TYPE 30 and 32) Under power fail conditions the valve leakage rate is at the next lower ANSI leakage class. 3. (ALL) For maximum trim life observe maximum sustained flowing differential pressure trim limits. See page 5. Stem Down Upper Port Lower Port The upper port opens and the lower port closes Common Port Upper Port Stem Up Lower Port The upper port closes and the lower port opens Common Port *PIPING NOTE: The Type 32 is NOT compatible with an elbow directly connected or in close proximity to the bottom port w/o the use of a flow straighter. Otherwise a minimum of 10 diameters of straight pipe are required for the bottom port connection. Type 32 Three-Way Diverting Valve Stem Down Stem Up Upper Port Lower Port Upper Port Lower Port Common Port The upper port opens and the lower port closes Three-Way Diverting Common Port The upper port closes and the lower port opens Series AMURACT AMB_PS_RevG_0418 8

ACTUATOR SPECIFICATIONS & FACTORY DEFAULT SETTINGS AMURACT ELECTRIC MOTOR ACTUATOR SPECIFICATIONS: Control Signal: Analog 4-20 madc (Factory Default), or 2-10 Vdc Control Action: 2-Way Valves, Increasing Signal Opens Valve (Factory Default) Reversible, Dip-Switch Selectable 3-Way Valves, Increasing Signal Raises Stem (Opening the L port and Closing the U port, Factory Default) Reversible, Dip-Switch Selectable Output: Linear Stem Lift (Factory Default 2-Way Valves), Non-linear Stem Lift (Factory Default 3-Way Valves) Dip-Switch Selectable Power Supply: 120 (110 to 130) VAC 50/60 Hz, 24 VAC, or 30 Vdc (F3 & F4), 220 (220 to 250) VAC 50/60 Hz (F5 & F6) Power Consumption: 50VA Peak, 30VA Normal Operation Timing: 12 Seconds Typical Feedback Signal: 4-20 madc (Factory Default),or 2-10 Vdc, Dip-Switch Selectable Fail Safe: Yes (Enerdrive Failsafe System, Stem Down (Factory Default), or Stem Up, Dip-Switch Selectable) Calibration: Push Button Auto-Calibration Torque: 120 in-lbs (F3 & F5), 240 in-lbs (F4 & F6) Motor: Brushless DC Motor Rating: 100% Duty Cycle Connections: Screw Terminal Block Wiring: 18 AWG Minimum Locations: No Rating (Standard), NEMA 4X (Optional with LS Standard Linkage Orientation) Temperature Limits: Ambient... 0 º F to 122 º F Relative Humidity: 5 to 95% Non-Condensing Weight: 5 Lbs (F3 & F5), 8 Lbs (F4 & F6) Approvals: UL pending, CE, c CSA us, AMURACT FACTORY DEFAULT SETTINGS Unless a purchase order specifically requests it to be configured differently, an AmurAct control valve will accept a 4-20 madc input signal, provide 4-20 ma feedback, will fail shut (lower port shut for 3-way valves) upon loss of either operating power or input signal or both, and will have linear stem lift on 2-way valves. NOTES: 1 Linkage Model LS at factory is aligned with the pipe center line. This configuration of linkage is suitable for process fluids up to 200º (AMA, AMC, AMD) and 250ºF (AMB) when the pipelineand valve are not insulated or up to 325ºF (AMA, AMC, AMD) and 340ºF (AMB) when the pipeline and valve are insulated. 2. Linkage Model LE must be installed perpendicular to the pipe center line. This configuration of linkage is suitable for process fluids up to 250ºF (AMA, AMC, AMD) and 290ºF (AMB) when the pipeline and valve are not insulated, or up to 400ºF (AMC), 450ºF (AMB), and 550ºF (AMA,AMD) when the pipeline and valve are insulated. The 180-degree offset anti-rotation tailpiece is integral to this design. 3. Actuators F3, F4, F5 and F6 are identical in appearance. 4. Loosening either the stem or bonnet connection will affect performance, may cause damage and will void the warranty. Refer to procedures in the IO&M instruction document. Contact the Warren Controls factory at (610) 317-096%0 before attempting to reconfigure or reposition either the motor or linkage. Failure to do so will void the warranty APPLICABLE ON 2-WAY VALVES ONLY LINEAR STEM LIFT VS. NON-LINEAR STEM LIFT Linear stem lift is the factory default dipswitch selection. Linear stem lift means the stem position is linear with respect to the input signal. For example if the valve is closed with a 0% input signal, the valve will be at 25% Stroke with a 25% input signal, at 50% Stroke with a 50% input signal, at 75% Stroke with a 75% input signal, and at 100% Stroke with a 100% input signal. Linear stem lift preserves the inherent flow characteristic of the valve. When non-linear stem lift is selected the actuator has an ever gain changing stroke curve that accelerates in the last half of the stroke and is relatively slow on startup. Extreme gain changes as present in the Non- linear configuration are difficult for a control system to manage. If an application s turndown requirements are only 3:1 to 5:1 for example such that a valve could be sized to only operate from 50% to 100% of stroke, some level of speed of response can be achieved in the Non-linear configuration. Otherwise, in all other circumstances, the Linear Stem Lift (factory default) will be the desired setting. In either case, correct control valve sizing is critical to good operation. 9 2600 Emrick Blvd Bethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com AMB_PS_RevG_0418

ACTUATOR ORIENTATIONS Factory default and alternate actuator orientations are shown. If the alternate actuator orientation is required, select code A under special options in AmurAct order code.!! IMPORTANT: SELECT THE CORRECT ACTUATOR ORIENTATION Each AmurAct actuator is precision factory calibrated on each valve prior to shipment. Field re-orientation of the actuator due to piping or other considerations can disturb the calibration and damage your AmurAct voiding the warranty. To prevent unneccessary field re-orientation be sure to select and order each AmurAct with the actuator in the correct orientation. AMURACT LS LO-TEMP 2-WAY ACTUATOR ORIENTATIONS DEFAULT ACTUATOR ORIENTATION ALTERNATE ACTUATOR ORIENTATION AMURACT LE HI-TEMP 2-WAY ACTUATOR ORIENTATIONS DEFAULT ACTUATOR ORIENTATION ALTERNATE ACTUATOR ORIENTATION Series AMURACT AMB_PS_RevG_0418 10

ACTUATOR ORIENTATIONS AMURACT LS LO-TEMP 3-WAY ACTUATOR ORIENTATIONS DEFAULT ACTUATOR ORIENTATION ALTERNATE ACTUATOR ORIENTATION 11 2600 Emrick Blvd Bethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com AMB_PS_RevG_0418

ACTUATOR ORIENTATIONS AMURACT LE HI-TEMP 3-WAY ACTUATOR ORIENTATIONS DEFAULT ACTUATOR ORIENTATION ALTERNATE ACTUATOR ORIENTATION Series AMURACT AMB_PS_RevG_0418 12

DIMENSIONS & WEIGHTS LS LS With Nema 4 Enclosure MOTOR WEIGHT LBS DIMENSIONS F3 & F5 5 lbs 9.13 x 5.2 x 3.55 F4 & F6 8 lbs 9.13 x 5.2 x 3.55 LE LINKAGE WEIGHT LBS DIMENSIONS LS 11 lbs 9.5 x 9.5 x 3.25 LE 11.2 lbs 16.81 x 9.5 x 3.25 13 2600 Emrick Blvd Bethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com AMB_PS_RevG_0418

SERIES: AMB Type 20, 28 DIMENSION (IN) Type 20 VALVE SIZE (IN) Variable 1/2, 3/4, 1 1-1/4 & 1-1/2 2 A B C Weight (LB) 250THD 4-7/8 5-3/4 6-1/2 300THD 5 6-1/8 6-1/2 300BWE 15-3/8 16-7/8 17 250THD 2-3/4 3-1/4 3-5/8 300THD & BWE 3 3-1/2 3-7/8 250THD 2-7/8 3-1/2 3-3/4 300THD & BWE 2-7/8 3-1/2 3-3/4 250THD 8-1/2 14-1/2 18-1/2 300THD 8 15-1/2 19 300BWE 9-1/2 18 22-1/2 DIMENSION (IN) Type 28 VALVE SIZE (IN) Variable 1/2, 3/4, 1 A B C Weight (LB) 250THD 4-7/8 300THD 5 300BWE 15-3/8 250THD 2-3/4 300THD & BWE 3 250THD 2-7/8 300THD & BWE 2-7/8 250THD 8-1/2 300THD 8 300BWE 9-1/2 SERIES: AMB Type 30, 32 DIMENSION (IN) Type 30 VALVE SIZE (IN) Variable 1/2, 3/4, 1 1-1/4 & 1-1/2 2 250THD 4-7/8 5-3/4 6-1/2 A 300THD 5 6-1/8 6-1/2 300BWE 15-3/8 16-7/8 17 250THD 2-23/32 3-13/16 4 B 300THD 2-23/32 3-3/8 3-3/4 300BWE 8 8-3/4 9 C 250THD 2-7/8 3-1/2 3-3/4 300THD & BWE 2-7/8 3-1/2 3-3/4 Weight (LB) 250THD 9 15-1/2 20 300THD 8 15 18-1/2 300BWE 10-1/2 19 23-1/2 DIMENSION (IN) Type 32 VALVE SIZE (IN) Variable 1 1-1/2 2 250THD 4-7/8 5-3/4 6-1/2 A 300THD 5 6-1/8 6-1/2 300BWE 15-3/8 16-7/8 17 250THD 3-15/32 3-13/16 4 B 300THD 2-23/32 3-3/8 3-3/4 300 BWE 8 8-3/4 9 C 250THD 2-7/8 3-1/2 3-3/4 300THD & BWE 2-7/8 3-1/2 3-3/4 250THD 9 16-1/2 21 Weight (LB) 300THD 8 16 19-1/2 300BWE 10-1/2 20 24-1/2 Actual shipping weights may vary. Face to face dimensions conform to Historical Warren Controls standard and are NOT ANSI/ISA compatible. C B A 2-Way or 3-Way Series AMURACT AMB_PS_RevG_0418 14

HEAT/SOUND PRESSURE LEVEL GUIDELINES Fluid Temperature Limit Thresholds Actuator Mounting vs Insulating Blankets The engineering data within our product specification will share information about MAX fluid temperature limits as if it is an absolute for any configurable valve assembly. It is not. The MAX fluid temperatures listed, sometimes as high as 800 Deg. F depending on the valve is only an absolute one for the valve body itself. It does not take into consideration the actuation. AmurAct actuators have their own MAX ambient temperature limit 122 ºF. It is nearly impossible to correlate JUST fluid temperature to determine when these actuators will have their ambient exceeded. When working with higher fluid temperatures thermal insulating blankets can dramatically reduce surface temperatures on pipes, valves and other fixtures in a fluid control system such that the ambient room temperatures in these environments are dramatically reduced as well. This is often required for valve actuators to reliably survive when fluid temperatures rise well above the safe ambient temperatures of the devices. Radiant heat and convected heat are the major sources for damage to these actuators. When a valve actuator is mounted to the side of a valve there is still radiant heat but convected heat is mostly eliminated. For globe control valves, having the actuator mounted vertically above the valve is best for optimum valve packing life but will then suffer the most with both radiant and convected heat to deal with. Alternatives to blankets and the mounting orientation listed include longer yoke actuators and extension bonnets on valves. These put distance between the heat sources and the components you are trying to protect from heat. THERE ARE SEVERAL FACTORS THAT INCLUDE BUT ARE NOT LIMITED TO: valve size bonnet style/size actuator orientation conducted heat versus radiated heat room ambient temperature ventilation distance from the valve body to the components of interest LE LINKAGE AND BLANKET LS LINKAGE AND BLANKET LE LINKAGE AND NO BLANKET LS LINKAGE AND NO BLANKET AMB 250º F 290º F 340º F ACTUATOR FLUID TEMPERATURE LIMITS 450º F 450º F (VBA limit) 425º F 400º F 375º F 350º F 325º F 300º F 275º F 250º F 225º F 200º F 150º F 0º F FLUID TEMP With all of these variables it is a challenge to come up with some guidelines. However, we have attempted to do that in the chart on page 16. 15 2600 Emrick Blvd Bethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com AMB_PS_RevG_0418

HEAT/SOUND PRESSURE LEVEL GUIDELINES Choose the right blanket vs At Warren Controls our AcoustiGuard & ThermiGuard blankets are nearly identical. In fact they have identical thermal properties. The AcoustiGuard has an additional layer of high density barium sulfate vinyl reflector for sound reflection. Each blanket is specifically designed in a one or two piece design that is made to be easily removable for valve servicing. When used in conjunction with high temperature fluids, significant energy savings, lower surface & ambient temperatures and a safer environment for employees are just some of the benefits. Valve Series AMB AMB 28 AMB 30 AMB 32 AMURACT BLANKETS 032515 Valve Series TMAX Valve Size Inches Thermiguard for Fluid Temperatures to 450º F Acoutstiguard for Fluid Temperatures to 450ºF End Connection PART # PART # 450F 1/2 250 NPT/ 300 NPT TB-282W-050-S AB-282W-050-S 450F 3/4 250 NPT/ 300 NPT TB-282W-075-S AB-282W-050-S 450F 1 250 NPT/ 300 NPT TB-282W-100-S AB-282W-050-S 450F 1-1/4 250 NPT/ 300 NPT TB-282W-125-S AB-282W-050-S 450F 1-1/2 250 NPT/ 300 NPT TB-282W-150-S AB-282W-050-S 450F 2 250 NPT/ 300 NPT TB-282W-200-S AB-282W-200-S 450F 1/2 250 NPT/ 300 NPT TB-282W-050-S AB-282W-050-S 450F 3/4 250 NPT/ 300 NPT TB-282W-075-S AB-282W-075-S 450F 1 250 NPT/ 300 NPT TB-282W-100-S AB-282W-100-S 450F 1/2 250 NPT/ 300 NPT TB-283W-050-S AB-283W-050-S 450F 3/4 250 NPT/ 300 NPT TB-283W-075-S AB-283W-075-S 450F 1 250 NPT/ 300 NPT TB-283W-100-S AB-283W-100-S 450F 1-1/4 250 NPT/ 300 NPT TB-283W-120-S AB-283W-125-S 450F 1-1/2 250 NPT/ 300 NPT TB-283W-150-S AB-283W-150-S 450F 2 250 NPT/ 300 NPT TB-283W-200-S AB-283W-200-S 450F 1/2 250 NPT/ 300 NPT TB-283W-100-S AB-283W-100-S 450F 1-1/2 250 NPT/ 300 NPT TB-283W-150-S AB-283W-150-S 450F 2 250 NPT/ 300 NPT TB-283W-200-S AB-283W-200-S Series AMURACT AMB_PS_RevG_0418 16

THIS DRAWING AND THE DEVICE, PROCESS, METHOD AND/OR PRODUCT SHOWN THEREIN ARE THE PROPRIETARY PROPERTY OF WARREN CONTROLS INCORPORATED. THIS DRAWING IS FOR REFERENCE PURPOSES ONLY. POSSESSION OF IT DOES NOT IN ITSELF CONVEY ANY RIGHT OR LICENSE TO MAKE, MANUFACTURE, USE AND/OR SELL THE DEVICE, PROCESS, METHOD OR PRODUCT SHOWN THEREIN NOR DOES IT CONVEY THE RIGHT OR LICENSE TO REPRODUCE THE DRAWING OR ANY PART THEREOF. SUCH RIGHTS OR LICENSES CAN ONLY BE GRANTED BY EXPRESS WRITTEN CONSENT OF WARREN CONTROLS INCORPORATED. D3400007 AMURACT TM ACTUATOR LS TYPICAL CONSTRUCTION 17 2600 Emrick Blvd Bethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com AMB_PS_RevG_0418

D3400007 AMURACT TM ACTUATOR LS TYPICAL CONSTRUCTION D Series AMURACT AMB_PS_RevG_0418 18

THIS DRAWING AND THE DEVICE, PROCESS, METHOD AND/OR PRODUCT SHOWN THEREIN ARE THE PROPRIETARY PROPERTY OF WARREN CONTROLS INCORPORATED. THIS DRAWING IS FOR REFERENCE PURPOSES ONLY. POSSESSION OF IT DOES NOT IN ITSELF CONVEY ANY RIGHT OR LICENSE TO MAKE, MANUFACTURE, USE AND/OR SELL THE DEVICE, PROCESS, METHOD OR PRODUCT SHOWN THEREIN NOR DOES IT CONVEY THE RIGHT OR LICENSE TO REPRODUCE THE DRAWING OR ANY PART THEREOF. SUCH RIGHTS OR LICENSES CAN ONLY BE GRANTED BY EXPRESS WRITTEN CONSENT OF WARREN CONTROLS INCORPORATED. D3400011 AMURACT TM ACTUATOR LE TYPICAL CONSTRUCTION 19 2600 Emrick Blvd Bethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com AMB_PS_RevG_0418

D3400011 AMURACT TM ACTUATOR LE TYPICAL CONSTRUCTION Series AMURACT AMB_PS_RevG_0418 20

AMB AmurAct Order Code SERIES: AMB Model VBA Series Valve Type Size Body Material End Connection VALVE BODY Trim Style Trim Material Trim Cv Packing Type 20 2-Way Single Seat 28 2-Way Lo- 30 3-Way Mixing 32 3-Way Diverting Type TYPE 20 TYPE 28 TYPE 30 TYPE 32 050 1/2 inch 075 3/4 inch 100 1 inch 125 1-1/4 inch 150 1-1/2 inch 200 2 inch Size Available 1/2 inch 3/4 inch 1 inch 1-1/4 inch 1-1/2 inch 2 inch 1/2 inch 3/4 inch 1 inch 1/2 inch 3/4 inch 1 inch 1-1/4 inch 1-1/2 inch 2 inch 1 inch 1-1/2 inch 2 inch B Bronze F CF8M S Screwed B Buttweld End E Equal % L Linear M Mod Lin Type 20 Equal % or Linear ONLY, Types 30/32, Linear Only, Types 28 Mod Lin Only S 316SS* B Bronze 6 Alloy 6 H 17-4 PH P PEEK NOTE: * Type 28, 316SS trim uses a harder Nitronic 60 seat. F Full Port 1 1st Port Reduction 2 2nd Port Reduction 3 3rd Port Reduction 4 4th Port Reduction NOTE: Port reductions only available on Type 20/28/30. Check pages 5 & 6 for availability. VALVE TYPE/TRIM MATERIAL COMBINATIONS: SIZE TRIM MATERIAL S B 6 H P 316 SS Bronze Alloy 6 17-4 PH PEEK 1/2 inch 20, 28, 30 N/A 20 20 20, 28 3/4 inch 20, 28, 30 N/A 20 20 20, 28 1 inch 20, 28, 30, 32SS 32 BRZ 20 20 20, 28 1-1/4 inch 20, 30 N/A 20 20 20 1-1/2 inch 20, 30, 32SS 32 BRZ 20 20 20 2 inch 20, 30, 32SS 32 BRZ 20 20 20 T Teflon V Vacuum Service L NLP FLUID TEMPERATURE LIMITS Valve Type 20 2-Way Single Seat 28 2-Way Low 30 3-Way Mixing 32 3-Way Diverting Body Material Code Trim Material Code Packing Type Code T MAX T MIN Bronze B 316 S, Alloy 6 6, 17-4 PH H, PEEK P EPDM L 400 F -20 F Bronze B 316 S, Alloy 6 6, 17-4 PH H, PEEK P Teflon T, Vacuum Service V 400 F 60 F CF8M F 316 S, Alloy 6 6, 17-4 PH H EPDM L 400 F -20 F CF8M F 316 S, Alloy 6 6, 17-4 PH H Teflon T, Vacuum Service V 450 F 60 F CF8M F PEEK P EPDM L 400 F -20 F CF8M F PEEK P Teflon T, Vacuum Service V 400 F 60 F Bronze B 316 S, PEEK P EPDM L 400 F -20 F Bronze B 316 S, PEEK P Teflon T, Vacuum Service V 400 F 60 F CF8M F 316 S EPDM L 400 F -20 F CF8M F 316 S Teflon T, Vacuum Service V 450 F 60 F CF8M F PEEK P EPDM L 400 F -20 F CF8M F PEEK P Teflon T, Vacuum Service V 400 F 60 F Bronze B 316 S EPDM L 400 F -20 F Bronze B 316 S Teflon T, Vacuum Service V 400 F 60 F CF8M F 316 S EPDM L 400 F -20 F CF8M F 316 S Teflon T, Vacuum Service V 450 F 60 F Bronze B Bronze B Teflon T, Vacuum Service V 300 F 60 F Bronze B Bronze B EPDM L 300 F -20 F CF8M F 316 S EPDM L 400 F 23 F CF8M F 316 S Teflon T, Vacuum Service V 450 F 60 F NOTE: -20 F T MIN temperature limit is for indoor applications with low humidity where ice will not form on the valve stem. 21 2600 Emrick Blvd Bethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com AMB_PS_RevG_0418

LINKAGE MOTOR ENCLOSURE RATING SPECIAL LS Standard Linkage with orientation parallel to the pipe line. LE Extended Temperature Linkage with orientation perpendicular to the pipeline and motor extended beyond linkage box. F3 120 in-lb Torque Motor with Enerdrive Fail Safe Back-Up 120VAC, 24VAC or 30Vdc Power Supply F4 240 in-lb Torque Motor with Enerdrive Fail Safe Back-Up 120VAC, 24VAC or 30Vdc Power Supply F5 120 in-lb Torque Motor with Enerdrive Fail Safe Back-Up 220VAC Power Supply 00 No rating, somewhat splash resistant with proper fittings E2 NEMA 4X enclosure with heater and thermostat for use on 24 vac supply voltage only. (Check availability before ordering.) E3 NEMA 4X enclosure with heater and thermostat for use on 120 vac supply voltage only. (Check availability before ordering.) 0 No Special Options S Special Options verbally described on order, priced separately A Alternate actuator orientation F6 240 in-lb Torque Motor with Enerdrive Fail Safe Back-Up 220VAC Power Supply Size MOTOR TO USE TYPE 20 1/2 inch F3 or F5 YES F4 or F6 YES 3/4 inch YES YES 1 inch YES YES 1-1/4 inch YES YES 1-1/2 inch YES YES 2 inch YES YES TYPE 28 1/2 inch YES NO 3/4 inch YES NO 1 inch YES NO TYPE 30 1/2 inch YES YES 3/4 inch YES YES 1 inch YES YES 1-1/4 inch YES YES 1-1/2 inch YES YES 2 inch YES* YES TYPE 32 1 inch YES YES 1-1/2 inch NO YES 2 inch NO YES Notes: Please refer to page 8 for Shut-off P ratings. *1SR Port only N4 Enclosure option for NEMA 4X. NOTE: Enclosure rating MUST match the operating voltage supplied to the motor.! IMPORTANT SELECT THE CORRECT ACTUATOR ORIENTATION Each AmurAct actuator is precision factory calibrated on each valve prior to shipment. Field re-orientation of the actuator due to piping or other considerations can disturb the calibration and damage your AmurAct voiding the warranty. To prevent unneccessary field re-orientation be sure to select and order each AmurAct with the actuator in the correct orientation. Series AMURACT AMB_PS_RevG_0418 22

AMB - is the breed defined for a wide range of compact 2-way and 3-Way applications. Available in bronze or CF8M bodies, this NPT end design is chocked full of design choices, from five different kinds of hard and soft trim to Cv s ranging from 0.25 up to 40...from 1/2 through 2. AMB PRODUCT SPEC 2600 EMRICK BLVD BETHLEHEM, PA 18020 USA 800-922-0085 WWW.WARRENCONTROLS.COM DEPENDABLE, RUGGED, PRECISION CONTROL VALVES AND ACCESSORIES