WMP-Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY WMP-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS. 3 inch.

Similar documents
MFM220 & MFM220DC Plastic-Bodied Magmeter

MFM300 Plastic-Bodied Magmeter

WMP-Series. Plastic-Bodied Magmeter Instructions ISO. 2 inch. Precision Flow Measurement. An ONICON Brand 9001:2008 PROUDLY MADE IN THE USA.

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

SERIES FLMG MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

AG2000 IRRIGATION MAGMETER INSTRUCTIONS

imag 4700 SERIES FLANGED MAGMETER

WMX-SERIES Flanged Magmeter

AG2000 Irrigation Magmeter

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS

Positive Displacement Flowmeters

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

PE202. Low Flow Magmeter Instructions. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

EX80-Series ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX81 EX82 EX :2008 ISO CERTIFIED COMPANY

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX :2008 ISO CERTIFIED COMPANY

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

TX100/200-SERIES INSERTION TURBINE INSTRUCTIONS TX101/201 TX115/215 ISO 9001:2008 CERTIFIED COMPANY

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

TX100/200-SERIES INSERTION TURBINE. T X / S E R I E S I N S E R T I O N T U R B I N E instru c tions TX101/201 TX115/215

TX115/215 Hot-tap Insertion Turbine Instructions

Ultra Mag SUBMITTAL PACKAGE

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

TX101/201 Insertion Turbine Instructions

ISTEC MAGNETIC METERS

SERIES TBS INSERTION TURBINE TBS-0XX TBS-1XX

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

SES. Stainless Single-Jet Meter Instructions PROUDLY MADE IN THE USA

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

TX101/201 Insertion Turbine Instructions

EX100/200 Series. Insertion Magnetic Flow Meter Instructions. EX11x EX21x. EX15x EX25x PROUDLY MADE IN THE USA

imag ISO 9001:2008 Municipal/Industrial Magmeter Instructions Flow Meters & Controls 9 001:2008 ISO CERTIFIED COMPANY CERTIFIED COMPANY

Hydro-Flow Model 3100

TX 115/215 Hot-tap Insertion Turbine Instructions

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Instructions EM 101 Low Flow Electromagnetic Flow Meters

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Signet 2517 Brass Paddlewheel Flow Sensor * *

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

S-Series. Low Flow Meter Instructions SPX SPT. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

Hydro-Flow Model 2300 Installation and Operation Guide B

Propeller Meters. Flow measurement solutions for water and wastewater

TABLE OF CONTENTS Service Information 2 Quick Start Instructions 4-5 Introduction 6 Specifications 6 Controls and Terminology

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

TURBINE METERS - WP Series

FT430/440/450 RATE/TOTAL INDICATOR INSTRUCTIONS

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Appendix. Clearance. Skewed profiles. Application Schematics

Hydro-Flow Model 2200 Installation and Operation Guide B

Propeller. Flowmeter. Technology. For the Real World.

Liquid Turbine Flow Meter OwnerÊs Manual

SeaMetrics Flow Meters and Flow Computers

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

AG3000. Irrigation Magmeter Instructions PROUDLY MADE IN THE USA

MULTI-JET WATER METERS

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

M SERIES Multi-Jet Cold Water Meter

EX800-Series. Electromagnetic Flow Sensor Instructions PROUDLY MADE IN THE USA

Outdoor Bottle Fillers

FLOW METERS FOR MINING

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

F-2700 SERIES INSERTION VORTEX FLOW METER

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

AG3000p. Irrigation Magmeter Instructions ISO 9001:2008. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

MODEL 200 MULTI-JET FLOW METER

Field IT Electro-Magnetic Flowmeters Sensors

Compu-Flow. Electromagnetic Insertion Flow Meter. Compu-Flow EXM MAG

5020 Series Injector

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Vortex Eggs Delta Flowmeter

Magnetic-inductive flow meter for hazardous areas

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

Model Model Model

MODEL 200 MULTI-JET FLOW METER

Model TUR-200D Turbine Flowmeter

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

SIGNET 7002 Vortex Flow Sensor ENGLISH

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

Inline Ultrasonic Flowmeter

F-2700 SERIES INSERTION VORTEX FLOW METER

Flow Measurement Solutions for Water & Waste Water INSTALLATION OPERATION & MAINTENANCE MANUAL

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

INSTRUMENTATION & CONTROL

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Series TTMP PVC Electronic Totalizing Meter

Magnetic Inductive Flowmeter EP / UMF2 (B)

imag 4700p Municipal/Industrial Magmeter Instructions imag 4700p PROUDLY MADE IN THE USA

G2 Industrial Grade Meters

Transcription:

-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS -Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 3 inch 2 inch 1 inch 9001:2008 ISO CERTIFIED COMPANY

GENERAL INFORMATION and FEATURES GENERAL INFORMATION The -Series is a full-bore, plastic-bodied electromagnetic flow meter designed for flow and usage monitoring applications in 1, 2 and 3 inch pipe. The polypropylene flow tube offers corrosion resistance to a wide range of chemicals. Its light weight and easy to install or remove from the pipe for inspection. With no moving parts, the magmeter permits unobstructed flow, minimizing flow disturbances and hence, straight pipe requirements. The -Series can be used in piping configurations where there is little space between the meter and an elbow or valve. The -Series, like other magmeters, are resistant to wear from sand and debris found in ground or surface water. Since there are no bearings or propeller to wear out, downtime and maintenance and repair costs are kept to a minimum. Because there are no mechanical parts in the flow stream, the meter tolerates high flows without damage. wastewater, gray water, irrigation metering, turf and landscape applications, and other water reclamation operations. In the event of DC power loss, or when changing the battery, the is designed to retain the internal settings and flow total. The 101 is externally powered via a 5-pin connector and the power cable also provides pulse output for use with a variety of Seametrics and other displays and controls for remote reading, data logging, pulse-to-analog conversion, and telemetry applications. The 104 is a battery-operated unit for use when pulse output is not required. The standard batteries are user replaceable with an approximate 1-2 year life depending on usage. An extended battery life option offers an estimated 2-4 year life depending on usage. The hinged, opaque polyethylene cover protects from dust and UV rays, while permitting easy access to the LCD flow rate and total display. The electronics housing is made of rugged powder-coated die-cast aluminum. It can be fitted with cross-drilled screws and seal wire for tamper-evidence. Flow rate and total can be displayed in a variety of units, customer-selected and factory-set. The -Series is used for tracking flow rate and total flow in usage monitoring applications, for instance, in compliance with regulatory requirements. These would include wells, industrial FEATURES Polyethylene protective cover LCD rate and total indicator Powder-coated die cast-aluminum electronics housing Cross-drilled screws (2) for tamper-evidence Seametrics Fitting Kit for 2 and 3 inch models 316SS electrodes Corrosion-resistant glass-filled polypropylene body Lightweight for easy handling 2 inch 1

SPECIFICATIONS* Pipe Size Fittings Pressure Operating Temperature Range Accuracy Flow Range Minimum Maximum Materials Body Electrodes Electronics Housing 1, 2 or 3 inch full port 1 inch NPTF, 2 or 3 inch flange clamps with 2 or 3 inch NPTF fitting kit 150 psi or 10.3 bar working pressure @ 70 F 10 to 130 F (-12 to 54 C) operating, -40 to 176 F (-40 to 80 C) non-operating +/-1% of reading (between 10% and 100% of max flow) +/-3% of reading (between cutoff and 10% of max flow) 1 inch: 2.3 GPM (.145 LPS) 2 inch: 6 GPM (.38 LPS) 3 inch: 14 GPM (.88 LPS) 1 inch: 110 GPM (6.94 LPS) 2 inch: 300 GPM (18.9 LPS) 3 inch: 670 GPM (42.3 LPS) Glass-filled polypropylene 316 stainless steel Diecast aluminum, powder-coated Display Security Power Display Cover Digits Units 101 104 Pulse Output Signal (101 Only) Pulse Rate (101 Only) Low Frequency (-PxU) High Frequency (-HF) Pulse/Unit Polyethylene Rate Total 6 8 Gallons/Minute, Cubic Feet/Second, Acre-Feet, Acre-Inch, Gallons, Gallons x 1000, Cubic Feet/Minute, Liters/Second Cubic Feet, Liters, Megaliters, Cubic Meters Liters/Minute, Cubic Meters/Minute Cross-drilled screws and tamper-evident seal (optional) 10-30 Vdc @ 60 ma max (15 ma average) NOTE: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation 6 each AA alkaline cells, replaceable. Estimated life is 1-2 years depending on usage (standard) 2 each C lithium batteries, replaceable. Estimated life is 2-4 years depending on usage (Extended battery life option) Current sinking pulse, opto isolated, 32 Vdc max at 10 ma max 1 unit/pulse out, pulse width of 10ms depending on unit selection 1 2 3 Pulse width 1.1 ms, min - max frequency, 3-150 hz 80 30 13 Empty Pipe Detection Conductivity Environmental Electrical Connection (101 Only) Hardware/software, conductivity-based >20 microsiemens/cm NEMA 4X standard 5 pin male circular connector, mates to industry standard cable *Specifications subject to change Please consult our website for current data (www.seametrics.com) DIMENSIONS Power/Output Cable - 101 Only 1 Inch 4.3 2 Inch 4.625 3 Inch 4.625 1.00 8.8 3.25 2.00 9.50 4.40 3.00 10.75 4.55 5.50 5.50 7.30 5.38 6.03 7.30 1.63 2.03 2.625 2

FLOW RANGE, INSTALLATION FLOW RANGE Minimum Maximum 1 2 3 Gal/Min Liter/Sec Gal/Min Liter/Sec Gal/Min Liter/Sec 2.3.145 6.38 14.88 110 6.94 300 18.9 670 42.3 INSTALLATION Piping Conditions. Installing the meter with a length of straight pipe at least two times the diameter upstream and one diameters downstream is highly recommended. Some piping conditions require more than this. See chart for recommendations. End Connections. The meter comes with Banjo union-type flange connections for ease in servicing the meter. To connect these to piping ends, a variety of kits are available from any Banjo dealer or from Seametrics. Follow the diagram below to make the connections. Step 1. Position gasket at either end Step 2. Place adapter against gasket, open screw clamps to clear flanges Step 3. Place screw-clamps over both adapter and meter flanges and tighten screws NOTE: Above installation instructions are for 101/104-200 (2 ) and 101/104-300 (3 ) only. The 101/104-100 (1 ) is provided with intergrated NPT female threaded ends. Position. This is an all position meter which can be installed either vertically or horizontally, register up, down or angled. However, entrained air or solids may make some positions preferable to others. See the position diagram for guidance. Electrode moved from top by rotating meter Intermittent air bubbles miss electrode Intermittent air bubbles pass over electrode Electrodes free from sediment build-up Possible sediment build-up Recommended: May prevent sediment or bubble problems Less Ideal: Air bubbles and sediment on the electrodes can affect accuracy 3

STRAIGHT and FULL PIPE RECOMMENDATIONS (X = diameter) Reduced Pipe 2X 1X Expanded Pipe 5X 1X Elbows Swirling Flow: Partially Open Butterfly Valve 2X 1X 5X 1X Recommended: Keep pipe full at meter for accuracy Not Ideal: Allows air pockets to form at meter Recommended: Keeps pipe full at meter for accuracy Not Ideal: Post-valve cavitation can create air pocket Recommended: Allows air to bleed off Not Ideal: Air can be trapped 4

ELECTRICAL CONNECTIONS, CABLE CONNECTIONS and OPERATION ELECTRICAL CONNECTIONS 104. The 104 is battery-powered totally self-contained and does not require any electrical connections (there is no output on the 104 model). 101. A connector is provided on the outside of the 101. To connect to the meter, plug the cable in and hand tighten the retaining threads. Follow the diagram to make connections. If you are using the pulse output, connect power first and determine that the meter is working properly by observing the display. Then connect the pulse output. CABLE CONNECTIONS Gray: Pin 5 = Ground Black: Pin 4 = ( ) Power Blue: Pin 3 = (+) Pulse White: Pin 2 = ( ) Pulse Brown: Pin 1 = (+) Power Shield Drain Wire OPERATION Grounding (101). For best performance, especially in chemically noisy environments, the gray ground wire and the bare drain wire should be connected together and to a good earth ground as close to the meter as possible. Metal pipe and fittings in contact with the fluid should also be bonded to the same earth ground with corrosion-resistant connections. Display. The display reads flow rate and accumulated total, in the units for which it was ordered. The top line is total, the bottom line is rate, and indicators give the units (ac-ft, GPM for instance.) Empty or partially-full pipe is automatically detected and is indicated by a reading of EP. Battery. The standard batteries are user replaceable with an approximate 1-2 year life depending on usage. An extended battery life option offers an estimated 2-4 year life depending on usage. On the battery-powered 104 there is a lowbattery indicator ( low bat ) when the battery voltage drops below a certain point. Batteries should be changed within four weeks of the appearance of this indicator. 5

MAINTENANCE, REPAIR and TROUBLE SHOOTING MAINTENANCE AND REPAIR There are no user-serviceable parts in the -Series meters except the batteries in the 104. Battery Replacement. When the low bat indicator appears, the batteries should be changed. Either six each AA alkaline cells are required, or two each C lithium cells with integrated wiring harness, depending on power option ordered with meter. To change the batteries, first remove the four screws which hold the top cover in place. Be careful not to lose the wash ers. Move the top cover to one side and remove the foam retainer which covers the battery tray or pack. > For units with AA alkaline batteries, remove the old bat teries from the battery tray, and replace them with fresh ones, taking care to fol low the polarity indicators in the battery tray. > For units with the optional C lithium batteries, carefully unplug each of the two battery wiring harness connectors. Slip the batteries out from under the elastic retainer, and replace them with the new batteries. Reconnect each of the two wiring harness connectors. The connectors are indexed for correct installation. Replace the foam retainer, then put the top cover back in place. Warning! Use Extreme Caution not to pinch wiring or other assembly parts under the housing seal - this may cause an ingress of water, voiding the product warranty. Replace the four screws and washers, then tighten them securely using cross-pattern to evenly compress the gasket. Environmental and Safety note - take care to dispose of all batteries in accordance with Federal, State, and Local regulations. TROUBLE SHOOTING Problem Probable Cause Try... Blank display: 101 Blank display: 104 Reading -EP- Flow but no flow rate reading No power to unit Batteries dead or misinstalled Empty or partly filled pipe Excessive air pockets or foaming Heavily coated electrodes Check power supply Check wiring Check polarity, replace batteries Rearrange piping to ensure full pipe Remove meter and wipe electrodes 6

Seametrics Incorporated 19026 72nd Avenue South Kent, Washington 98032 USA (P) 253.872.0284 (F) 253.872.0285 1.800.975.8153 www.seametrics.com LT-65200337-012714 1/27/2014