MVOLT

Similar documents
80 Watt Multi-Purpose LED Area Light

LEDMPAL15 15 Watt Multi-Purpose LED Area Light

Performance Package LED Color Distribution Lens Accessories Dimming FLC FLC5 FLC10 FLC20 FLF. Flat Lens Frosted WWD 2 FLCAS

TWH LED TWP LED TWH TWP LED LED

Lumark PFPRV PREVAIL POLE AND FIXTURE COMBO

Catalog Number. Notes

Lumark PFPRV PREVAIL POLE AND FIXTURE COMBO

VINCI-LED Wall/Area/Flood Lighting

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor

LEDMPALPRO LED Area Luminaire

Autobahn Series ATB0 Roadway Lighting

Bavaria Downs. Chaska, MN. Lighting

The PREMIER TM. II Series

Evolve LED Area Lighting EALS

The KAX LED Family. Outdoor. The KAX LED Family

Evolve LED Area Lighting EALP

Phuzion LED High Bay Wet location listed

PhuzionL Large LED High Bay

GE Evolve LED Area Lighting Scalable EASC High Lumen

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

BOW SX - LED Luminaire

GreenCobra LED Street Light GCL G-Series Specification Data Sheet

Visor Compact Architectural LED Wallpack. Technical Specifications VISOR TM. Visor Configuration Information. Project Catalog Number Type Date

SLIM AREA LIGHT. 50,000 Rated Life Hours. Product Description. 360W Type 3 Lens. 100W Type 5 Lens. Color Choices. Features & Benefits

SP Spot. G1 Gen-1 SF Slip Fitter Mount (fits to 2-3/8" O.D. tenon) RSP Rectangular Spot. YK Yoke Mount. A33 Asymmetric 33 Flood


Housing. Mounting EPA. Warranty. Listing

Phuzion Crane Light LED High Bay

SOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot

Evolve LED Flood Lighting EFH1

Evolve LED Area Lighting

LED LINEAR QUICK SUMMARY CO W SI MODEL CORTANA

OSQ Series OSQ LED Area/Flood Luminaire Large

QuadroMAX LED FIXTURE QM SERIES

CFL-LED-KIT Compact FloodLight, LED 2.0 Upgrade Kit kl_cfl_ledkit_spec.pdf

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

Project: 1 IP65 Rated fixtures are rated for use outdoors where exposed directly to water from rain or irrigation.

GE Evolve LED Flood & Spot Lighting EFM1

ORDERING INFORMATION: 120 Volts (120)

Autobahn Series ATBO Roadway Lighting

ARIETA 13 Architectural LED Area Luminaire AR13 M2 Series Specification Data Sheet

GE Evolve LED Post Top Contemporary Twin Support Post Top (EPTC)

ARIETA 18 Architectural LED Area Luminaire AR18 M2 Series Specification Data Sheet

BDT Product Sales & Support (951) (800)

PG Series. Our PG Series has now been expanded to complete your entire site needs. With added housing shapes of round and square we offer

H700 H710 H720. Compact Flood. Typical Applications. Features. Lamp Types. Approvals SPECIALTY LANDSCAPE

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf

19.0" (482mm) Performance Summary 3.1" (79mm) NanoOptic Precision Delivery Grid optic Receptacle location (ordered as an option)

Taxonomies, Classifications, and Categories LED FLOODLIGHTS, WALLPACKS, BOLLARDS & LANDSCAPE LIGHTING

XSP C F 30K + 24 SV Q# 01. Insulation Class CCT 30K 3000K (80 CRI) 35K 3500K 40K 4000K 57K 5700K. + Class 1 ^ Class 2

XSP High Output Series XSP2 High Output LED Street/Area Luminaire Double Module

LSA TM series. BBE LED Roadway, Area & Parking Lighting Luminaire V9: LSA-04/06/16. Performance Data:

XSP Series - IP66. XSP2 TM LED Street /Area Light Double Module - Version B. Product Description. Performance Summary. Accessories

KAD250MR3TBSPD04 Wall Fixture

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

GE Evolve LED Area Lighting Scalable EASC

Autobahn Series ATB2 Roadway Lighting

V-Bollard Architectural LED Luminaire / Bollard

KIT-XSP-AP60-34-G0 Fitter kit to mount to 34mm tenon 303mm XSP B 02 2LG A 30K + 24 SV DIM 01. Insulation Class CCT. Voltage

Evolve LED Roadway Lighting

304 Series LED Recessed Canopy Luminaires

XSP Series XSPR LED Street/Area Luminaire Version A

OSQ Series LED Area/Flood Luminaire Medium

XSP C 02 2LG E 30K + 24 SV Q# 01. Insulation Class CCT. Voltage 30K 3000K (80 CRI) 40K 4000K 57K 5700K. + Class 1 ^ Class 2

V-Bollard Architectural LED Luminaire / Bollard

E-Cobra LED Street and Area Light EC M2 Series Specification Data Sheet

Cree Edge Series LED Area Luminaire Round

FC Well Light. Quick Facts. LED Well Lights. LED Well Lights

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl

Lumark NAV NAVION. 1-6 Light Squares

Driver Info. Construction Thermal Management: Superior thermal management with die-cast aluminum heatsink. Ambient Temperature:

Cree Edge Series LED Area/Flood Luminaire

ALG LED Area Light K lm 21000lm 33000lm 100W 150W 300W. Type III Type V

Levanto DETAILS. IP67 EPA: 0.96 FT 2 Weight: 35 lbs - 16 kg

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

Paseo. Luminaire CE21T4UF Pole PA40 base cover BD11

CD20S2 DENVER. Luminaire. Optics. Sources Lamp 4K = High power LED, 4000K (neutral white) ±150K.

LUMINAIRE SCHEDULE _CUSiteLightingSchedule_092815_GJ.xls 9/28/2015 WATTS / LUMINAIRE ALTERNATE MANUFACTURERS

Evolve LED Flood Light

The Induction Cobrahead Series can be used in a variety of roadway lighting applications. All of the

XSP C F 30K + 24 SV Q# 01. Insulation Class CCT. Voltage 30K 3000K (80 CRI) 40K 4000K 57K 5700K. + Class 1 ^ Class 2

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC

ARIETA 13 Architectural LED Area Luminaire AR13 N-Series Specification Data Sheet

1SA / ALT3P35/ 120L5K277/ WH/ A26

GE Evolve LED Roadway Lighting ERL1-ERLH-ERL2

ARIETA 13 Architectural LED Area Luminaire AR13 N-Series Specification Data Sheet

LED DockLight. Sustainable lighting with powerful output. UL listed for wet locations. Standard 5 year warranty

OSQ High Output LED Area/Flood Luminaire featuring Cree TrueWhite Technology. Product Specifications. Electrical Data*

Evolve LED Roadway Lighting

BDT Product Sales & Support (951) (800)

XSP Series XSP2 LED Street/Area Luminaire Double Module Version C

Options. Pole and Arm. Suitable for wet locations

XSP High Output Series

UNIVERSAL LIGHT 15-24W. IP64 WARRANTY

LED Parking Garage. Optional motion sensor

Glass Washington Postlite LED HOLOPHANE. Decorative Glass Washington Postlite LED

Symphony DETAILS. IP66 EPA: 1.8 FT 2 Weight: 52 lbs - 24 kg


Augusta POST-TOP. IP66 EPA: 2.2 FT 2 Weight: 48 lbs - 22 kg

GE Evolve LED Roadway Lighting ERL1-ERLH-ERL2

Transcription:

High Lumen LED Flood Luminaire Notes Type Hit the Tab key or mouse over the page to see all interactive elements. Introduction Specifications EPA: 5.4 ft 2 (0.50 m 2 ) Depth: 10 (25.4 cm) Width: 25 (62.5 cm) Height: 22 (55.8 cm) Overall Height: Weight: 31 (78.4 cm) 70 lbs (31.75 kg) W H OH D The Lithonia High Lumen LED Flood Size 2 () is capable of replacing 1000W metal halide luminaires while delivering exceptional energy savings. Its long service life of over 100,000 hours or 20+ years of nighttime use makes it ideal for high mounting applications, eliminating expensive lamp changes. The instant-on feature eliminates the long strike and re-strike times associated with HID floods. Available in both yoke and slip fitter mounts, the is easy to install on existing poles and brackets. Ordering Information EXAMPLE: LED P1 40K WFL MVOLT IS DDBXD LED Series Performance package Color temperature Distribution Voltage Mounting Options Finish (required) LED P1 P2 P3 30K 40K 50K 3000 K 4000 K 5000 K VNSP Very narrow spot (7 ) 1 NSP Narrow spot (15 ) SP Spot (22 ) NFL Narrow flood (45 ) MNFL Medium narrow flood (70 ) MFL Medium flood (6x6) WFL Wide flood (6x7) MVOLT 2 120 2 208 2 240 2 277 2 347 480 Shipped included IS Integral slipfitter (fits 2-3/8 O.D. tenon) YKC62 Yoke with 16-3 SO cord Shipped installed PER5 NEMA twist-lock receptacle only (no controls) 3,4 SF Single fuse (120, 277, 347V) 5 DF Double fuse (208, 240, 480V) 5 CFB Black faceplate Shipped separately 6 UBV Upper/bottom visor (universal) FV Full visor WG Wire guard VG Vandal guard (polycarbonate) DDBXD DBLXD DNAXD DWHXD Dark bronze Black Natural aluminum White Accessories Ordered and shipped separately. FTS CG6 DDBXD U Slipfitter for 2-3/8 to 2-7/8 OD tenons; mates with yoke mount (specify finish) DSHORT SBK U Shorting cap 7 DLL127F 1.5 JU Photocell - SSL twist-lock (120-277V) 7 DLL347F 1.5 CUL JU Photocell - SSL twist-lock (347V) 7 DLL480F 1.5 CUL JU Photocell - SSL twist-lock (480V) 7 For more mounting options, visit our Floodlighting Accessories pages. For more control options, visit DTL and ROAM online. UBV DDBXD U Upper/bottom visor accessory (specify finish) FV DDBXD U Full visor accessory (specify finish) VG DDBXD U Vandal guard accessory (specify finish) WG U Wire guard accessory NOTES 1. VNSP includes an external reflector that ships separately. For installation instructions, refer to the instruction sheet provided with the reflector. 2. MVOLT driver operates on any line voltage from 120-277V. Specify 120, 208, 240 or 277 options only when ordering with fusing (SF, DF options). 3. Specifies a ROAM enabled luminaire with 0-10V dimming capability. Additional hardware and services required for ROAM deployment; must be purchased separately. Call 1-800-442-6745 or email: sales@roamservices.net. 4. For units with a photocontrol receptacle, the mounting must be restricted to ± 45 from horizontal aim per ANSI C136.10-2010. 5. Single fuse (SF) requires 120, 277 or 347 voltage option. Double fuse (DF) requires 208, 240 or 480 voltage option. 6. Also available as separate accessories; see Accessories information at left. 7. Requires luminaire to be specified with PER5 option. Ordered and shipped as a separate line item. Page 1 of 5

Performance Data Lumen Output Lumen values are from photometric tests performed in accordance. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Contact factory for performance data on any configurations not shown here. Performance Package P1 P2 P3 System Watts 328W 487W 598W Dist. Type Field Angle Beam Angle 30K (3000 K, 70 CRI) 40K (4000 K, 70 CRI) 50K (5000 K, 70 CRI) H V H V Max Cd Lumens LPW Max Cd Lumens LPW Max Cd Lumens LPW VNSP 30 30 11 10 434,853 31,127 95 450,297 32,233 98 456,410 32,670 100 NSP 50 49 26 25 127,616 36,042 110 132,149 37,322 114 133,943 37,829 115 SP 52 50 31 30 119,648 37,432 114 123,897 38,762 118 125,579 39,288 120 NFL 76 75 49 48 55,292 37,531 114 57,256 38,864 118 58,033 39,391 120 MNFL 92 91 68 67 31,938 37,411 114 33,521 39,266 120 33,521 39,266 120 MFL 101 114 84 103 18,401 37,904 116 19,055 39,250 120 14,772 39,783 121 WFL 124 133 107 113 14,073 37,576 115 14,226 38,911 119 17,277 39,439 120 VNSP 30 30 11 10 596,587 42,704 88 617,776 44,221 91 626,163 44,822 92 NSP 50 49 26 25 175,081 49,447 102 181,299 51,203 105 183,760 51,899 107 SP 52 51 31 30 164,148 51,355 105 169,978 53,179 109 172,286 53,901 111 NFL 76 75 49 48 75,857 51,489 106 78,551 53,318 109 79,617 54,042 111 MNFL 92 91 68 67 43,817 51,326 105 45,373 53,149 109 45,989 53,870 111 MFL 101 114 84 103 25,250 52,000 107 26,139 53,847 111 20,269 54,578 112 WFL 124 133 107 113 19,310 51,550 106 19,990 53,381 110 23,707 54,106 111 VNSP 28 28 10 9 787,413 49,438 83 837,947 52,610 88 841,908 52,859 88 NSP 45 45 23 23 239,669 56,590 95 255,050 60,222 101 256,256 60,507 101 SP 49 48 29 29 209,101 58,502 98 222,520 62,257 104 223,572 62,551 105 NFL 72 71 46 45 94,977 58,019 97 101,072 61,742 103 101,550 62,034 104 MNFL 87 85 64 63 56,393 57,755 97 60,012 61,461 103 60,296 61,752 103 MFL 100 113 82 102 24,570 60,373 101 31,332 64,248 107 20,090 64,552 108 WFL 123 132 107 114 18,790 59,775 100 23,566 63,611 106 23,496 63,912 107 Lumen Ambient Temperature (LAT) Multipliers Use these factors to determine relative lumen output for average ambient temperatures from 0-40 C (32-104 F). Ambient Lumen Multiplier 0 C 32 F 1.05 10 C 50 F 1.04 20 C 68 F 1.01 25 C 77 F 1 30 C 86 F 0.98 40 C 104 F 0.94 Projected LED Lumen Maintenance Operating Hours 0 25,000 50,000 100,000 Lumen Maintenance Factor LED P1 1 0.98 0.96 0.93 LED P2 1 0.98 0.96 0.93 LED P3 1 0.93 0.89 0.83 Electrical Load Power Package System Watts Current (A) 120V 208V 240V 277V 347V 480V P1 328W 2.8 1.6 1.4 1.2 1.0 0.8 P2 487W 4.1 2.3 2.0 1.8 1.4 1.1 P3 598W 5.0 2.8 2.4 2.1 1.7 1.3 Mounting, Options and Accessories IS - Integral slipfitter (fits 2-3/8 O.D. tenon) YKC62 Yoke with 16-3 SO cord UBV Upper/Bottom visor (universal) FV Full visor VG Vandal guard WG Wire guard CFB Black faceplate Optics Depending on the distribution chosen, luminaires are built using internal and external reflectors or hybrid silicone optical technology. Internal reflectors MFL, WFL Hybrid silicone optics NSP, SP, NFL, MNFL Internal and external reflectors VNSP Page 2 of 5

Photometric Diagrams To see complete photometric reports or download.ies files for this product, visit Lithonia Lighting s HLF Size 2 homepage. Isofootcandle plots for the LED P3 40K. Distances are in units of mount height (20ft). LEGEND (% Max cd) 10% 20% 30% 40% 50% 60% 75% 90% VNSP Test No. LTL29803P0 tested in accordance NSP Test No. LTL29794P0 tested in accordance SP Test No. LTL29798P0 tested in accordance NFL Test No. LTL29788P0 tested in accordance MNFL Test No. LTL29796P0 tested in accordance MFL Test No. LTL27153P0 tested in accordance WFL Test No. LTL27159P0 tested in accordance Mounting Summary The following is a list of approved mounting brackets for use with the. These are rated for use in up to 90mph wind zones. Steel Bullhorns (3) 3/8" x 1/2" set screws @120 41" (3) 3/8" x 1/2" set screws @120 3 120 90 Cap 2-3/8" O.D.Tubing 2-3/8" O.D.Tubing BS28 21 150 1.0 (0.09) 2 @ 180 2 x 70 = 140 BS32 32 150 1.6 (0.14) 3 @ 180 3 x 70 = 210 BS38 34 150 1.3 (0.12) 3 @ 120 3 x 70 = 210 BS49 44 150 1.6 (0.14) 4 @ 90 4 x 70 = 280 0 2.3 (0.21) 5.6 (0.52) 15 2.5 (0.23) 6.0 (0.56) 30 2.9 (0.26) 6.8 (0.63) 45 4.2 (0.39) 9.4 (0.87) 60 4.6 (0.42) 10.2 (0.95) 90 5.4 (0.50) 11.8 (1.10) 0 2.3 (0.21) 8.5 (0.79) 15 2.5 (0.23) 9.1 (0.85) 30 2.9 (0.26) 10.3 (0.96) 45 4.2 (0.39) 14.2 (1.32) 60 4.6 (0.42) 15.4 (1.43) 90 5.4 (0.50) 17.8 (1.65) 0 2.3 (0.21) 8.2 (0.76) 15 2.5 (0.23) 8.8 (0.82) 30 2.9 (0.26) 10.0 (0.93) 45 4.2 (0.39) 13.9 (1.29) 60 4.6 (0.42) 15.1 (1.40) 90 5.4 (0.50) 17.5 (1.63) 0 2.3 (0.21) 10.8 (1.00) 15 2.5 (0.23) 11.6 (1.08) 30 2.9 (0.26) 13.2 (1.23) 45 4.2 (0.39) 18.4 (1.71) 60 4.6 (0.42) 20.0 (1.86) 90 5.4 (0.50) 23.2 (2.16) Page 3 of 5

Mounting Summary The following is a list of approved mounting brackets for use with the. These are rated for use in up to 90mph wind zones. *Aluminum Bullhorns 15" 41-1/2" RBA28 RBA32 RBA28 RBA38 RBA49 15" * This can only be used with 4.0 OD tenon/pole tops *RBA28 8.4 100 1.3 (0.12) 2 @ 180 2 x 70 = 140 *RBA32 14.3 100 1.7 (0.15) 3 @ 120 3 x 70 = 210 *RBA38B 12.5 100 2.0 (0.18) 3 @ 180 3 x 70 = 210 *RBA49 17.5 100 2.2 (0.20) 4 @ 90 4 x 70 = 280 0 2.3 (0.21) 5.9 (0.55) 15 2.5 (0.23) 6.3 (0.59) 30 2.9 (0.26) 7.1 (0.66) 45 4.2 (0.39) 9.7 (0.90) 60 4.6 (0.42) 10.5 (0.98) 90 5.4 (0.50) 12.1 (1.12) 0 2.3 (0.21) 8.6 (0.80) 15 2.5 (0.23) 9.2 (0.85) 30 2.9 (0.26) 10.4 (0.97) 45 4.2 (0.39) 14.3 (1.33) 60 4.6 (0.42) 15.5 (1.44) 90 5.4 (0.50) 17.9 (1.66) 0 2.3 (0.21) 8.9 (0.83) 15 2.5 (0.23) 9.5 (0.88) 30 2.9 (0.26) 10.7 (0.99) 45 4.2 (0.39) 14.6 (1.36) 60 4.6 (0.42) 15.8 (1.47) 90 5.4 (0.50) 18.2 (1.69) 0 2.3 (0.21) 11.4 (1.06) 15 2.5 (0.23) 12.2 (1.13) 30 2.9 (0.26) 13.8 (1.28) 45 4.2 (0.39) 19.0 (1.77) 60 4.6 (0.42) 20.6 (1.91) 90 5.4 (0.50) 23.8 (2.21) *Steel Cross Arms (Square Poles only) Tenon 4" x 2-3/8" Dia. Front Cap Tenon 4" x 2-3/8" Dia. Front Cap SBS28 SBS38 (4) 3/8"-16 Set Screws (4) 3/8"-16 Set Screws *Requires T20 (2-3/8 max OD) tenon on pole for mounting SBS28* 30 250 1.1 (0.10) 2 @ 180 2 x 70 = 140 SBS38* 42 150 1.7 (0.15) 3 @ 180 3 x 70 = 210 0 2.3 (0.21) 5.7 (0.53) 15 2.5 (0.23) 6.1 (0.57) 30 2.9 (0.26) 6.9 (0.64) 45 4.2 (0.39) 9.5 (0.88) 60 4.6 (0.42) 10.3 (0.96) 90 5.4 (0.50) 11.9 (1.11) 0 2.3 (0.21) 8.6 (0.80) 15 2.5 (0.23) 9.2 (0.85) 30 2.9 (0.26) 10.4 (0.97) 45 4.2 (0.39) 14.3 (1.33) 60 4.6 (0.42) 15.5 (1.44) 90 5.4 (0.50) 17.9 (1.66) Page 4 of 5

Mounting Summary The following is a list of approved mounting brackets for use with the. These are rated for use in up to 90mph wind zones. Aluminum Cross Arms (Square Poles only) 18" SBA28 SBA38 SBA49 18" SBA28-4 12 100 0.9 (0.08) 2 @ 180 2 x 70 = 140 SBA38-4 17 100 1.5 (0.13) 3 @ 180 3 x 70 = 210 SBA49-4 22 100 1.7 (0.15) 4 @ 90 4 x 70 = 280 0 2.3 (0.21) 5.5 (0.51) 15 2.5 (0.23) 5.9 (0.55) 30 2.9 (0.26) 6.7 (0.62) 45 4.2 (0.39) 9.3 (0.86) 60 4.6 (0.42) 10.1 (0.94) 90 5.4 (0.50) 11.7 (1.09) 0 2.3 (0.21) 8.4 (0.78) 15 2.5 (0.23) 9.0 (0.84) 30 2.9 (0.26) 10.2 (0.95) 45 4.2 (0.39) 14.1 (1.31) 60 4.6 (0.42) 15.3 (1.42) 90 5.4 (0.50) 17.7 (1.64) 0 2.3 (0.21) 10.9 (1.01) 15 2.5 (0.23) 11.7 (1.09) 30 2.9 (0.26) 13.3 (1.24) 45 4.2 (0.39) 18.5 (1.72) 60 4.6 (0.42) 20.1 (1.87) 90 5.4 (0.50) 23.3 (2.16) Wall Mount s Weight (lbs.) EPA Luminaire Tilt Luminaire EPA Total EPA 7" 9/1 Dia. 7" 13" FRWB 12 80 N/A 1 1 x 70 = 70 0 2.3 (0.21) 15 2.5 (0.23) 30 2.9 (0.26) 45 4.2 (0.39) N/A 60 4.6 (0.42) 90 5.4 (0.50) FEATURES & SPECIFICATIONS INTENDED USE The contemporary design of the High Lumen LED Flood reflects its embedded high performance LED technology and its versatility. It is ideal for large signage, retail, sports fields, truck yards, and many commercial applications. CONSTRUCTION The High Lumen LED Flood s die-cast aluminum housing has integral heat sink fins to optimize thermal management through conductive and convective cooling. The LED drivers are mounted in direct contact with the casting to promote low operating temperature and long life. Housing is completely sealed against moisture and environment contaminants (IP66). Low EPA 5.7 ft 2 (0.52 m 2 ) for optimized wind loading. FINISH Exterior parts are protected by a zinc-infused Super Durable TGIC thermoset powder coat finish that provides superior resistance to corrosion and weathering. A tightly controlled multi-stage process ensures a minimum 3 mils thickness for a finish that can withstand extreme climate changes without cracking or peeling. OPTICS Specular reflectors are engineered for superior field-to-beam ratios, uniformity, and spacing. Light engines are available in 3000 K (70 CRI min.), 4000 K (70 CRI min.) and 5000 K (70 CRI min.) configurations. Optional visors minimize uplight and reduce light trespass. ELECTRICAL Light engines consist of chip-on-board (COB) LEDs directly coupled to the housing to maximize heat dissipation and promote long life (100,000 hrs at 25 C, L83). Class 1 electronic driver has a power factor >90%, THD <20%, and has an expected life of 100,000 hours with <1% failure rate. 10kV surge protection meets a minimum Category C low operation per ANSI/IEEE C62.41.2. INSTALLATION Integral adjustable slipfitter or yoke mounting assemblies facilitate quick and easy installation with a variety of mounting accessories. This secure connection enables the High Lumen LED Flood to withstand up to a 1.5 G vibration load rating per ANSI/IEEE C136.31. LISTINGS CSA certified to U.S. and Canadian standards. IP 66 rated for outdoor applications. Rated for -40 C minimum ambient conditions. DesignLights Consortium (DLC) qualified product. Not all versions of this product may be DLC qualified. Please check the DLC Qualified Products List at www.designlights.org to confirm which versions are qualified. WARRANTY 5-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/customerresources/terms_and_conditions.aspx. Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 C. Specifications subject to change without notice. Page 5 of 5