PLA-RP BA/BA2/BA3 PEAD-RP JA(L) PEAD-RP EA(2) PEAD-RP GA PKA-RP HAL PKA-RP KAL PKA-RP GAL PKA-RP FAL(2)

Similar documents
PLFY-P-VCM-E PLFY-P-VBM-E

SUBMITTAL DATA: MXZ-4C36NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM. Hermetic Fan Motor (ECM) F.L.A Sound Pressure Level

PARTS CATALOG. February 2009 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. OCB413 REVISED EDITION-B

SUBMITTAL DATA: MXZ-4C36NAHZ MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

Engineering Data Book. High Static Duct 8, 10HP Digital Inverter. Indoor Unit. Outdoor Unit

SUBMITTAL DATA: MXZ-5C42NAHZ MULTI-INDOOR INVERTER HEAT PUMP SYSTEM. Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features

SERVICE MANUAL OUTDOOR UNIT. No. OB387

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER ASY9USBCW AOY9UGBC ASY12USBCW AOY12UGBC. Models Indoor unit Outdoor unit

Digital Inverter 4 series

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

Split-Sky Air RMX-JZ Super Multi Plus

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS.

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

CASSETTE type SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS

CHP20R Basic Unit CHP

SERVICE MANUAL OUTDOOR UNIT. No. OB386

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

CB29M. Multi Position 60 HZ A I R H A N D L E R S. 3 to 5 Tons Optional Electric Heat 5 to 30 kw CB 29 M 41 1 E N G I N E E R I N G D A T A

/ LOSSNAY / LGH-RS2-E2

CEILING CONCEALED LOSSNAY LGH-25RX3

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

GREEN REFRIGERANT R-410A

Engineering Data Book

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type

CEILING CONCEALED LOSSNAY LGH-80RX3

technical data air conditioning systems MXS-B Multi Application Split Sky Air

CEILING CONCEALED LOSSNAY LGH-50RX3

CDK25JVEC, CDK35JVEC, CDX25BVMC, CDX25BVMC9, CDX25JVEC, CDX35BVMC, CDX35BVMC9, CDX35JVEC, CDX50AVMC9, CDX60AVMC9 CDK35HAVER1, CDK60HAVER1

Cooling Capacity Tons (kw) 024 = 2 (7.0) 030 = 2.5 (8.8) 036 = 3 (10.6) 048 = 4 (14.1) 060 = 5 (17.6)

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

CEW SERIES CEILING EXPOSED HORIZONTAL FAN COIL UNITS

Amendment Sheet. Code : ADB-FR Date : Superceded : nil REFRIGERANT CIRCUIT DIAGRAM

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

Engineering Data Book

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS RO-25A RO-25RA RO-30A RO-30RA RC-25A RC-25RA RC-30A RC-30RA

Outdoor Units R-410A ARX-GV1B

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

CBH17-95V Horizontal Unit CB V

PL-612. Split Indoor Units AT09HV2S AT13HV2S AT18HV2S FT09GV2S FT13GV2S FT15GV2S, FT18GV2S FT24GV2S, FT28GV2S FTE09GV2S, FTE12GV2S FTE18GV2S

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

Fault Codes. J control

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

SERVICE MANUAL MU-GA20VB- MU-GA20VB- MU-GA25VB- MU-GA25VB- MU-GA35VB- E1 OUTDOOR UNIT. No. OB386. Wireless type Models HFC

Engineering Data Book

VRF. Technical Data Book. DVM IDU_Vertical AHU for NA (R410A, 60Hz, HP) Model : AM***JNZDCH/AA

PL Split Indoor Units FTKD25GVM, FTKD35GVM FTKD25GVM4, FTKD35GVM4. Split Outdoor Units RKD50GVM RKD60GVM RKD50GVM4 RKD60GVM4

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

ASU18RLB ASU24RLB AOU18RLB AOU24RLB SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS

CHP

PARTS CATALOG R410A AIR TO WATER HEAT PUMP. May No.OCB540. Outdoor unit [Model names]

PL-702. Split Outdoor Units RD50FV1K RD60FV1K

PCB COMMERCIAL SERIES

SERVICE MANUAL MUH-GA25VB - E1 MUH-GA25VB - MUH-GA35VB - E1 HFC. Wireless type Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No. OB387 R410A CONTENTS

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air

PL-804. Remote Controller (RoHS application) BRC7F634F, BRC7F635F

M1 TYPE SLIM VARIABLE STATIC PRESSURE HIDE AWAY CONCEALED DUCT

Split Outdoor Units (RoHS application) RKS71HVMG RXG09HVJU, RXG12HVJU, RXG15HVJU RXS25HV2C RXS60GMV2C RXS60HVMA, RXS71HVMA RXS72GMV2C

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Model 8144NC Fresh Air Ventilator

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

technical data Systems FXMQ-MVE Conceiled ceiling unit (large)

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air

Oil Cooler AKZ328-D142 PL

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES

PL-604. Compressor 3H64QML-F. Split Indoor Units FTYN25DV1A, FTYN35DV1A FTYN50DV1A FTYN60DV1A. Decolation Panels BYCP125K-W1

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

Bosch BOVA Split System Heat Pump

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

6. Troubleshooting. 6-1 Basic items for trouble shooting. Samsung Electronics 17

Q5RD Series Single Packaged Heat Pump, Single Phase

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

GCL Technical Manual. Split System Air Conditioner GCL TAC 640. Electronic Control. Air Conditioners

SERVICE MANUAL MUH-GA20VB- MUH-GA20VB- MUH-GA25VB- MUH-GA25VB- MUH-GA35VB- E1 OUTDOOR UNIT. No. OB387. Wireless type Models HFC

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

PL Split Indoor Units (RoHS application) CDKS30JVLT CDKS40JVLT CDXS30JVLT CDXS40JVLT

VHIA High-Static Ducted Indoor Units - 60HZ

Bosch Climate 5000 Ductless Minisplit System

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)

FCC DUCTABLE AIR TREATMENT UNIT

Transcription:

SPLIT-TYPE, HET PUMP IR CDITIERS TECHNICL DT BOOK <Indoor unit> [Model names] R4 PL-RP B/B/B PED-RP J(L) PED-RP E() PED-RP G PK-RP HL PK-RP KL PK-RP GL PK-RP FL() March No. OCS REVISED EDITI-B INVERTER Revision : PL-RP B, PK-RP HL/KL and PED-RP J(L) are added, and the data of PUHZ-HRP H has been modified in REVISED EDITI-B. Some descriptions have been modified. Please void OCS REVISED EDITI-. <Outdoor unit> [Model names] PUHZ-HRP7/VH PUHZ-HRP/YH PUHZ-HRP7/VH PUHZ-HRP/YH CTENTS. REFERENCE SERVICE MNUL. SPECIFICTIS. OUTLINES ND DIMENSIS 4. WIRING DIGRM 4. REFRIGERNT SYSTEM DIGRM 6 6. PERFORMNCE CURVES 8 7. CORRECTI FCTORS 8. PPLICBLE EXTENSI PIPE FOR ECH MODEL 4 9. IR FLOW DT 44. NOISE CRITERI CURVES. OPTIL PRTS 74 Zubadan

REFERENCE SERVICE MNUL For information on service, please refer to the service manual as follows. -. INDOOR UNIT Model Name Service Ref. Service Manual No. PL-RP////B PL-RP7//B PL-RPB PK-RP/HL PK-RP/KL PED-RP///7//J(L) PL-RP////B#.UK PL-RP7//B.UK PL-RPB PK-RP/HL PK-RP/KL.TH PED-RP///7//J(L).UK OCH4 OCB4 OCH49 OCB49 OCH4 OCB4 OCH4 OCB4 HWE8 BWE8 PK-RP/GL PK-RP/GL# OC PK-RP/FL PK-RPFL PED-RP//7/E PED-RP/E PK-RP/FL# PK-RPFL# PED-RP//7/E#.UK PED-RP/E#.UK OC HWE PED-RP/7/G PED-RP/7/G#.UK HWE6 -. OUTDOOR UNIT Model Name Service Ref. Service Manual No. PUHZ-HRP7/VH PUHZ-HRP/YH PUHZ-HRP7/VH PUHZ-HRP/YH PUHZ-HRP7/VH PUHZ-HRP/YH PUHZ-HRP7/VHR PUHZ-HRP/YHR OCH4 OCB4

SPECIFICTIS -. CEILING CSSETTE TYPE Model name Indoor unit Outdoor unit Cooling Capacity Btu/h kw Total input kw EER Energy label class SHF Heating Capacity Btu/h kw Total input kw COP Energy label class Booster heater kw Power supply Phase Cycle Hz Voltage V Breaker size Indoor unit ir flow CMM (-Medium-Medium-) CFM External pressure Pa Sound level (-Medium-Medium-) External finish (Panel) Dimension Unit (Panel) Weight Unit (Panel) Field drain pipe O.D. db() W : mm D : mm H : mm W : inch D : inch H : inch kg lbs mm inch Outdoor unit ir flow CMM CFM Sound level at cooling db() Sound level at heating db() External finish Dimension W : mm D : mm H : mm W : inch D : inch H : inch Weight kg lbs Refrigerant pipe size Gas side O.D. mm inch Liquid side O.D. mm inch Refrigerant pipe length Height difference m Length m PL-RP7B PL-RPB PUHZ-HRP7VH PUHZ-HRPVH 4, 4, 7. ( 4.9-8. ). ( 4.9 -.4 ).94.44.66 4..7.74 7, 8, 8. ( 4. -. ). ( 4. - 4. ).9.4 4. 4.4 - - 4-6 - 8-49 - 6-6 - 7 8 - - - 4 - - 6-7 - 8-9 - - 4-7 - White Munsell 6.4Y 8.9/.4 8 (9) 8 (9) 8 () 98 () -/6 (7-/8) -/6 (7-/8) -/6 (-/8) -/4 (-/8) (6) () 7 (6) () -/4, Ivory Munsell Y 7.8/. 9 +, 7-/8 + -/6 -/8 6.88 /8 9. /8 Max. Max. 7 NOTE:. Rating conditions (ISO T) Cooling Indoor : D.B. 7 C (8 F) W.B. 9 C (66 F) Outdoor : D.B. C (9 F) W.B. 4 C (7 F) Heating Indoor : D.B. C (68 F) Outdoor : D.B. 7 C (4 F) W.B. 6 C (4 F) Refrigerant piping length (one way) : m (6ft.). Guaranteed operating range. Guaranteed voltage Indoor Outdoor 98~64V, Hz 4. bove data are based on the indicated voltage. Cooling Heating Upper limit D.B. C, W.B. C D.B. 46 C er limit D.B. 9 C, W.B. C D.B. - C * Upper limit D.B. 8 C D.B. C, W.B. C er limit D.B. 7 C D.B. - C, W.B. - C Indoor unit Outdoor unit Single phase V Hz Single phase V Hz * If optional air protect guide is installed : D.B.-8 C PL-RPB PUHZ-HRPVH 4,. ( 4.9 -.4 ).44 4..74 8,. ( 4. - 4. ).4 4.4 - - - 6-7 - 8-9 - - 4-7 - 98 () -/4 (-/8) 6 (6) 7 ()

Model name Indoor unit Outdoor unit Cooling Capacity Btu/h kw Total input kw EER Energy label class SHF Heating Capacity Btu/h kw Total input kw COP Energy label class Booster heater kw Power supply Phase Cycle Hz Voltage V Breaker size Indoor unit ir flow CMM (-Medium-Medium-) CFM External pressure Pa Sound level (-Medium-Medium-) db() External finish (Panel) Dimension W : mm Unit (Panel) D : mm H : mm W : inch D : inch H : inch Weight kg Unit (Panel) lbs Field drain pipe O.D. mm inch Outdoor unit ir flow CMM CFM Sound level at cooling db() Sound level at heating db() External finish Dimension W : mm D : mm H : mm W : inch D : inch H : inch Weight kg lbs Refrigerant pipe size Gas side O.D. mm inch Liquid side O.D. mm inch Refrigerant pipe length Height difference m Length m PL-RPB PL-RPB PL-RPB PUHZ-HRPYH PUHZ-HRPYH PUHZ-HRPYH 4, 4, 4,7. ( 4.9 -.4 ). ( 4.9 -.4 ). (. - 4. )...79 4. 4...74.74.7 8, 8, 47,8. ( 4. - 4. ). ( 4. - 4. ) 4. (. - 6. )...7 4. 4..9 - - - 6 - - 6 - - - 6 - - - 8-7 - 8-9 - 7-8 - 9-78 - 88-99 - 9-4 - 7 - - 4-7 - 4-6 - 9-4 7 (6) () White Munsell 6.4Y 8.9/.4 8 (9) 8 (9) 98 () -/6 (7-/8) -/6 (7-/8) -/4 (-/8) 6 (6) 7 () -/4, Ivory Munsell Y 7.8/. 9 +, 7-/8 + -/6 -/8 4 9.88 /8 9. /8 Max. Max. 7 NOTE:. Rating conditions (ISO T) Cooling Indoor : D.B. 7 C (8 F) W.B. 9 C (66 F) Outdoor : D.B. C (9 F) W.B. 4 C (7 F) Heating Indoor : D.B. C (68 F) Outdoor : D.B. 7 C (4 F) W.B. 6 C (4 F) Refrigerant piping length (one way) : m (6ft.). Guaranteed operating range. Guaranteed voltage Indoor Outdoor 98~64V, Hz(HRP, Y : 4~47V, Hz) 4. bove data are based on the indicated voltage. Cooling Heating Upper limit D.B. C, W.B. C D.B. 46 C er limit D.B. 9 C, W.B. C D.B. - C * Upper limit D.B. 8 C D.B. C, W.B. C er limit D.B. 7 C D.B. - C, W.B. - C Indoor unit Outdoor unit Single phase V Hz phase V Hz * If optional air protect guide is installed : D.B.-8 C 7 (6) () 4

Model name Indoor unit Outdoor unit Cooling Capacity Btu/h kw Total input kw EER Energy label class SHF Heating Capacity Btu/h kw Total input kw COP Energy label class Booster heater kw Power supply Phase Cycle Hz Voltage V Breaker size Indoor unit ir flow CMM (-Medium-Medium-) CFM External pressure Pa Sound level (-Medium-Medium-) db() External finish (Panel) Dimension W : mm Unit (Panel) D : mm H : mm W : inch D : inch H : inch Weight kg Unit (Panel) lbs Field drain pipe O.D. mm inch Outdoor unit ir flow CMM CFM Sound level at cooling db() Sound level at heating db() External finish Dimension W : mm D : mm H : mm W : inch D : inch H : inch Weight kg lbs Refrigerant pipe size Gas side O.D. mm inch Liquid side O.D. mm inch Refrigerant pipe length Height difference m Length m PL-RPB PL-RPB PL-RPB PUHZ-HRPVH PUHZ-HRPYH PUHZ-HRPYH 4, 4, 4,7. ( 4.9 -.4 ). ( 4.9 -.4 ). (. - 4. )...87....74.74.7 8, 8, 47,8. ( 4. - 4. ). ( 4. - 4. ) 4. (. - 6. )...88.6.6.6 - - - 6 - - 6 - - - 8-7 - 8-9 - 78-88 - 99-9 - 4-7 - 4-6 - 9-4 White Munsell 6.4Y 8.9/.4 8 (9) 8 (9) 98 () -/6 (7-/8) -/6 (7-/8) -/4 (-/8) (6) () -/4, Ivory Munsell Y 7.8/. 9 +, 7-/8 + -/6 -/8 4 6 9.88 /8 9. /8 Max. Max. 7 NOTE:. Rating conditions (ISO T) Cooling Indoor : D.B. 7 C (8 F) W.B. 9 C (66 F) Outdoor : D.B. C (9 F) W.B. 4 C (7 F) Heating Indoor : D.B. C (68 F) Outdoor : D.B. 7 C (4 F) W.B. 6 C (4 F) Refrigerant piping length (one way) : m (6ft.). Guaranteed operating range. Guaranteed voltage Indoor Outdoor 98~64V, Hz(HRP, Y : 4~47V, Hz) 4. bove data are based on the indicated voltage. Cooling Heating Upper limit D.B. C, W.B. C D.B. 46 C er limit D.B. 9 C, W.B. C D.B. - C * Upper limit D.B. 8 C D.B. C, W.B. C er limit D.B. 7 C D.B. - C, W.B. - C Indoor unit Outdoor unit Single phase V Hz V:Single phase V Hz, Y: phase V Hz * If optional air protect guide is installed : D.B.-8 C

-. CEILING-CCELED TYPE Model Name Indoor Unit PED-RP7J(L) PED-RPJ(L) PED-RPJ(L) PED-RPJ(L) Outdoor Unit PUHZ-HRP7VH PUHZ-HRPVH PUHZ-HRPYH PUHZ-HRPYH Cooling Capacity Btu/h 4, 4, 4, 4,7 kw 7. (. - 8.). (4.9 -.4). (4.9 -.4). (. - 4.) Total Input kw. (.).6 (.4).6 (.4).89 (.87) EER. (.).7 (.9).7 (.9). (.) Energy label class SHF.8.8.8.84 Heating Capacity Btu/h 7, 8, 8, 47,8 kw 8. (. -.). (4. - 4.). (4. - 4.) 4. (. - 6.) Total Input kw.4...88 COP.4.6.6.6 Energy label class B Booster heater kw - - - - Power supply Phase [ Cycle Hz Voltage V Breaker size 6 Indoor unit ir fl ow CMM 7. - - 4-9 - 4 4-9 - 4 9. -. - 4 ( - - ) CFM 68-74 - 88 847 -,4 -, 847 -,4 -,,4 -, -,48 External pressure Pa / / 7 / / Sound level ( - - /Pa) db() 6 - - 4 9-4 - 8 9-4 - 8-6 - External fi nish Galvanized sheets Dimension W : mm,, D : mm 7 H : mm W : inch 4-/6 -/8 D : inch 8-7/8 H : inch 9-7/8 Weight kg () 4 () 4 () 4 (4) lbs 7 (7) 9 (89) 9 (89) 9 (9) Field drain pipe O.D. mm inch -/4 Outdoor Unit ir fl ow CMM CFM, Sound level at cooling db() Sound level at heating db() External finish Ivory Munsell Y 7.8/. Dimension W : mm 9 D : mm + H : mm, W : inch 7-/8 D : inch + -/6 H : inch -/8 Weight kg 4 lbs 6 9 Refrigerant pipe size Refrigerant pipe length Gas side O.D. mm.88 inch /8 Liquid side O.D. mm 9. inch /8 Height difference m Max. Length m Max. 7 NOTE:. Rating conditions (ISO T) Cooling Indoor : D.B. 7 C (8 F) W.B. 9 C (66 F) Outdoor : D.B. C (9 F) W.B. 4 C (7 F) Heating Indoor : D.B. C (68 F) Outdoor : D.B. 7 C (4 F) W.B. 6 C (4 F) Refrigerant piping length (one way) : m (6ft.). Guaranteed voltage. Guaranteed operating range Indoor unit : 98 ~ 64V, Hz Indoor Outdoor Outdoor unit : 98 ~ 64V, Hz (V) Cooling Upper limit D.B. C, W.B. C D.B. 46 C 4 ~ 47V, Hz (Y) er limit D.B. 9 C, W.B. C D.B. - C * 4. bove data are based on the indicated voltage. Heating Upper limit D.B. 8 C D.B. C, W.B. C Indoor unit Single phase V Hz er limit D.B. 7 C D.B. - C, W.B. - C Outdoor unit (V) Single phase V Hz (Y) phase V Hz * If optional air protect guide is installed : D.B.-8 C 6

Model name Indoor unit Outdoor unit Cooling Capacity Btu/h kw Total input kw EER Energy label class SHF Heating Capacity Btu/h kw Total input kw COP Energy label class Booster heater kw Power supply Phase Cycle Hz Voltage V Breaker size Indoor unit ir flow CMM (-) CFM External pressure Pa Sound level (-) db() External finish (Panel) Dimension W : mm Unit (Panel) D : mm H : mm W : inch D : inch H : inch Weight kg Unit (Panel) lbs Unit drain pipe PED-RP7E PED-RPE PUHZ-HRP7VH PUHZ-HRPVH PUHZ-HRP7VH PUHZ-HRPVH 4, 4, 7. (4.9-8. ). ( 4.9 -.4 )..6..7.8.86 7, 8, 8. ( 4. -. ). ( 4. - 4. ).4..4.6 B - - (VH)/ (VH) -. - 4 76-88,8 -,48 7 7 7-4 44- Galvanized sheets,7,4 7 46-/8 -/6 9-/8 -/6 44 6 97 4 R (External thread) Outdoor unit ir flow CMM CFM Sound level at cooling db() Sound level at heating db() External finish Dimension W : mm D : mm H : mm W : inch D : inch H : inch Weight kg lbs Refrigerant pipe size Gas side O.D. mm inch Liquid side O.D. mm inch Refrigerant pipe length Height difference m Length m 7, (VH)/ (VH) (VH)/ (VH) Ivory Munsell Y 7.8/. 9 +, 7-/8 + -/6 -/8 6.88 /8 9. /8 Max. Max. 7 NOTE:. Rating conditions (ISO T) Cooling Indoor : D.B. 7 C (8 F) W.B. 9 C (66 F) Outdoor : D.B. C (9 F) W.B. 4 C (7 F) Heating Indoor : D.B. C (68 F) Outdoor : D.B. 7 C (4 F) W.B. 6 C (4 F) Refrigerant piping length (one way) : m (6ft.). Guaranteed operating range. Guaranteed voltage Indoor Outdoor 98~64V, Hz 4. bove data are based on the indicated voltage. Cooling Heating Upper limit D.B. C, W.B. C D.B. 46 C er limit D.B. 9 C, W.B. C D.B. - C * Upper limit D.B. 8 C D.B. C, W.B. C er limit D.B. 7 C D.B. - C, W.B. - C Indoor unit Outdoor unit Single phase V Hz Single phase V Hz * If optional air protect guide is installed : D.B.-8 C

Model name Indoor unit Outdoor unit Cooling Capacity Btu/h kw Total input kw EER Energy label class SHF Heating Capacity Btu/h kw Total input kw COP Energy label class Booster heater kw Power supply Phase Cycle Hz Voltage V Breaker size Indoor unit ir flow CMM (-) CFM External pressure Pa Sound level (-) db() External finish (Panel) Dimension W : mm Unit (Panel) D : mm H : mm W : inch D : inch H : inch Weight kg Unit (Panel) lbs Unit drain pipe PED-RPE PED-RPE PUHZ-HRPYH PUHZ-HRPYH PUHZ-HRPYH PUHZ-HRPYH 4, 4,7. ( 4.9 -.4 ). (. - 4. ).6.89.7..86.8 8, 47,8. ( 4. - 4. ) 4. (. - 6. )..88.6.6 - - 6. - 4. - 4,8 -,48,8 -,48 7 7 44-44 - Galvanized sheets,4 7 -/6 9-/8 -/6 6 4 R (External thread) Outdoor unit ir flow CMM CFM Sound level at cooling db() Sound level at heating db() External finish Dimension W : mm D : mm H : mm W : inch D : inch H : inch Weight kg lbs Refrigerant pipe size Gas side O.D. mm inch Liquid side O.D. mm inch Refrigerant pipe length Height difference m Length m 8, (YH)/ (YH) (YH)/ (YH) Ivory Munsell Y 7.8/. 9 +, 7-/8 + -/6 -/8 4 9.88 /8 9. /8 Max. Max. 7 NOTE:. Rating conditions (ISO T) Cooling Indoor : D.B. 7 C (8 F) W.B. 9 C (66 F) Outdoor : D.B. C (9 F) W.B. 4 C (7 F) Heating Indoor : D.B. C (68 F) Outdoor : D.B. 7 C (4 F) W.B. 6 C (4 F) Refrigerant piping length (one way) : m (6ft.). Guaranteed operating range. Guaranteed voltage Indoor Outdoor Indoor unit:98~64v, Hz Outdoor unit:4~47v, Hz 4. bove data are based on the indicated voltage. Cooling Heating Upper limit D.B. C, W.B. C D.B. 46 C er limit D.B. 9 C, W.B. C D.B. - C * Upper limit D.B. 8 C D.B. C, W.B. C er limit D.B. 7 C D.B. - C, W.B. - C Indoor unit Outdoor unit Single phase V Hz phase V Hz * If optional air protect guide is installed : D.B.-8 C

Model name Indoor unit Outdoor unit Cooling Capacity Btu/h kw Total input kw EER Energy label class SHF Heating Capacity Btu/h kw Total input kw COP Energy label class Booster heater kw Power supply Phase Cycle Hz Voltage V Breaker size Indoor unit ir flow CMM (-) CFM External pressure Pa Sound level (-) db() External finish (Panel) Dimension W : mm Unit (Panel) D : mm H : mm W : inch D : inch H : inch Weight kg Unit (Panel) lbs Unit drain pipe mm inch Outdoor unit ir flow CMM CFM Sound level at cooling db() Sound level at heating db() External finish Dimension W : mm D : mm H : mm W : inch D : inch H : inch Weight kg lbs Refrigerant pipe size Gas side O.D. mm inch Liquid side O.D. mm inch Refrigerant pipe length Height difference m Length m 9 PED-RP7G PED-RPG PED-RPG PUHZ-HRP7VH PUHZ-HRPVH PUHZ-HRPYH PUHZ-HRP7VH PUHZ-HRPVH PUHZ-HRPYH 4, 4, 4, 7. ( 4.9-8. ). ( 4.9 -.4 ). ( 4.9 -.4 )..8.8....8.86.86 7, 8, 8, 8. ( 4. -. ). ( 4. - 4. ). ( 4. - 4. ).4.8.8.4.4.4 B B B - - - (VH)/ (VH) 6-6.- 76-88 9-,6 //7 //7-8/7-4/7-4 -4/4-4/4-46 Galvanized sheets,7,4 7 7 46-/8-9/6 9-/8 -/6 4 9 R (External thread) -/4, (VH, YH)/ (VH, YH) (VH, YH)/ (VH, YH) Ivory Munsell Y 7.8/. 9 +, 7-/8 + -/6 -/8 4 6 9.88 /8 9. /8 Max. Max. 7 NOTE:. Rating conditions (ISO T) Cooling Indoor : D.B. 7 C (8 F) W.B. 9 C (66 F) Outdoor : D.B. C (9 F) W.B. 4 C (7 F) Heating Indoor : D.B. C (68 F) Outdoor : D.B. 7 C (4 F) W.B. 6 C (4 F) Refrigerant piping length (one way) : m (6ft.). Guaranteed operating range. Guaranteed voltage Indoor Outdoor 98~64V, Hz(HRPY : 4~47V, Hz) 4. bove data are based on the indicated voltage. Cooling Heating Upper limit D.B. C, W.B. C D.B. 46 C er limit D.B. 9 C, W.B. C D.B. - C * Upper limit D.B. 8 C D.B. C, W.B. C er limit D.B. 7 C D.B. - C, W.B. - C Indoor unit Outdoor unit Single phase V Hz V:Single phase V Hz, Y: phase V Hz * If optional air protect guide is installed : D.B.-8 C

-. WLL-MOUNTED TYPE Model Name Indoor Unit PK-RPKL PK-RPKL Outdoor Unit PUHZ-HRPVH PUHZ-HRPYH Cooling Capacity Btu/h 4, kw. (4.9 -.4) Total Input kw.9 EER.4 Energy label class SHF.7 Heating Capacity Btu/h 8, kw. (4. - 4.) Total Input kw. COP.6 Energy label class Booster heater kw - Power supply Phase [ Cycle Hz Voltage V Breaker size 6 Indoor unit ir fl ow ( - - ) CMM - - 6 CFM 7-8 - 9 External pressure Pa Sound level db() 4-4 - 49 ( - - /Pa) External finish Munsell.Y 9./. Dimension W : mm,7 D : mm 9 H : mm 6 W : inch 46-/6 D : inch -/8 H : inch 4-/8 Weight kg lbs 46 Field drain pipe O.D. mm 6 inch /8 Outdoor Unit ir fl ow CMM CFM, Sound level at cooling db() Sound level at heating db() External finish Ivory Munsell Y 7.8/. Dimension W : mm 9 D : mm + H : mm, W : inch 7-/8 D : inch + -/6 H : inch -/8 Weight kg 4 lbs 6 9 Refrigerant Gas side O.D. mm.88 pipe size inch /8 Liquid side O.D. mm 9. inch /8 Refrigerant pipe length Height difference m Max. Length m Mx. 7 NOTE:. Rating conditions (ISO T) Cooling Indoor : D.B. 7 (8 F) W.B. 9 (66 F) Outdoor : D.B. (9 F) W.B. 4 (7 F) Heating Indoor : D.B. (68 F) Outdoor : D.B. 7 (4 F) W.B. 6 (4 F) Refrigerant piping length (one way) : m (6ft.). Guaranteed operating range Indoor Outdoor Cooling Upper limit D.B. C, W.B.. C D.B. 46 C er limit D.B. 9 C, W.B. C D.B. - C Heating Upper limit D.B. 8 C D.B. C, W.B. C er limit D.B. 7 C D.B. - C, W.B. - C. Guaranteed voltage 98~64V, Hz (V) / 4~47V, Hz (Y) 4. bove data are based on the indicated voltage. Indoor unit Single phase V Hz Outdoor unit V : Single phase V Hz Y : phase V Hz. If optional air protect guide is installed : D.B.-

Model name Indoor unit Outdoor unit Cooling Capacity Btu/h kw Total input kw EER Energy label class SHF Heating Capacity Btu/h kw Total input kw COP Energy label class Booster heater kw Power supply Phase Cycle Hz Voltage V Breaker size Indoor unit ir flow CMM (-) CFM External pressure Pa Sound level (-) db() External finish (Panel) Dimension W : mm Unit (Panel) D : mm H : mm W : inch D : inch H : inch Weight kg Unit (Panel) lbs Field drain pipe I.D. mm inch Outdoor unit ir flow CMM CFM Sound level at cooling db() Sound level at heating db() External finish Dimension W : mm D : mm H : mm W : inch D : inch H : inch Weight kg lbs Refrigerant pipe size Gas side O.D. mm inch Liquid side O.D. mm inch Refrigerant pipe length Height difference m Length m PK-RPFL PK-RPFL PUHZ-HRPVH PUHZ-HRPYH PUHZ-HRPVH PUHZ-HRPYH 4, 4,. ( 4.9 -.4 ). ( 4.9 -.4 ).9.9.4.4.77.77 8, 8,. ( 4. - 4. ). ( 4. - 4. )...6.6 - - (VH)/ (VH) 6-8 78-99 4-46 White Munsell.4Y 7.7/.8 68 66-/8 9-/4 -/8 8 6 /6, (VH, YH)/ (VH, YH) (VH, YH)/ (VH, YH) Ivory Munsell Y 7.8/. 9 +, 7-/8 + -/6 -/8 4 6 9.88 /8 9. /8 Max. Max. 7 NOTE:. Rating conditions (ISO T) Cooling Indoor : D.B. 7 C (8 F) W.B. 9 C (66 F) Outdoor : D.B. C (9 F) W.B. 4 C (7 F) Heating Indoor : D.B. C (68 F) Outdoor : D.B. 7 C (4 F) W.B. 6 C (4 F) Refrigerant piping length (one way) : m (6ft.). Guaranteed operating range. Guaranteed voltage Indoor Outdoor 98~64V, Hz(HRPY : 4~47V, Hz) 4. bove data are based on the indicated voltage. Cooling Heating Upper limit D.B. C, W.B. C D.B. 46 C er limit D.B. 9 C, W.B. C D.B. - C * Upper limit D.B. 8 C D.B. C, W.B. C er limit D.B. 7 C D.B. - C, W.B. - C Indoor unit Outdoor unit Single phase V Hz V:Single phase V Hz, Y: phase V Hz * If optional air protect guide is installed : D.B.-8 C

OUTLINES ND DIMENSIS INDOOR UNIT PL-RPB PL-RPB PL-RPB PL-RP7B PL-RPB PL-RPB PL-RP7B PL-RPB PL-RPB PL-RPB Fresh air intake hole Ceiling hole ~4 8~9 ~4 8 Suspension bolt pitch ~4 Detail connecting of Branch duct(both aspects) 9 9 Cut out hole Unit : mm 8 (7.) Branch duct hole Remote controller terminal block Indoor unit/outdoor unit connecting terminal block Indoor power supply terminal block(option part) Suspension bolt pitch 7 + - 6 8~9 Ceiling hole Branch duct hole 7 Burring hole pitch 4-.8 Burring hole Cut out hole 67 ir intake grille 9 Suspension bolt M or W/8 7 Suspension bolt lower edge 9 C ir outlet hole 8 D ~7 Control wire entry M 87. 8 Drain pipe Connected the attached 84 77 connected to VP- ( socket. ) M Power supply wire, Indoor unit/outdoor unit connecting wire entry 97 ir intake hole M M 4 Ceiling Grille Drain hole Drain pump clean hole and Drain emergency drainage hole 97 ir intake hole (7.) 6 9 7 + uto vane (ir outlet) ~4 B Vane motor Keep approximately to mm space between unit ceiling and ceiling slab. Receiver Detail drawing of fresh air intake hole 8 Burring hole -.8 DEFROST/STND BY lamp Operation lamp Burring hole pitch Cut out hole Ceiling In case of standard grille : PLP-6B / PLP-6BMD In case of uto-grille : PLP-6BJ In case of wireless remote controller : PLP-6BLM Emergency operation switch<cooling>and Emergency Up/Down switch<up> Emergency operation switch<heating>and Emergency Up/Down switch<down> L.L Filter uto Grille ir intake grille up/down discharge ir intake grille Ceiling Max. 4.m Ceiling Grille mm or more 6 Indoor unit mm or more Obstacle ir outlet hole 9 Indoor unit mm or more 8 6 8mm or more from floor For high attachment Note. Please choose the Grille from a standard grille, uto-grille.. s for drain pipe, please use VP-(O.D. PVC TUBE). Drain pump is included. Raise is max 8mm from the ceiling.. s for suspension bolt, please use M or W/8. (Procured at local site) 4. Electrical box may be removed for the service purpose. Make sure to slack the electrical wire little bit for control/ power wires connection.. The height of the indoor unit is able to be adjusted with the grille attached. 6. For the installation of the optional high efficiency filter or optional multi-functional casement. ) Requires E or more space between transom and ceiling for the installation. ) dd mm to the dimensions marked on the figure. ) The optional high efficiency filter must be used jointly with optional multi-functional casement, 7. When installing the branch ducts, be sure to insulate adequately. Otherwise condensation and dripping may occur. (It becomes the cause of dew drops/water dew.) 8. s for necessary installation/service space, please refer to left figure. Floor Models PL-RP/B PL-RPB PL-RP7B,B PL-RP,B PL-RPB PL-RP,,B Refrigerant pipe 6. Flared connection /4F Refrigerant pipe 6. / 9. Flared connection /4F / /8F (compatible) Refrigerant pipe 9. Flared connection /8F Refrigerant pipe.7 Flared connection /F Refrigerant pipe.88 Flared connection /8F B C D E 8 4 8 87 8 98 74 8 77 4

PED-RP,,, 7,, J Unit : mm xe-.9 Suspension bolt hole 4-4x Slot 8 8 x(e-)=f 7 D (Duct) ir outlet 7 64 (Suspension bolt pitch) ir inlet B(Suspension bolt pitch) C G ir Filter Refrigerant piping Flare connection (liquid) -.9 78 (Duct) Refrigerant piping Flare connection (gas) 7 7 8 Drain pipe (O.D. ) 6 67 6 Drain pump 4 Drain pipe(o.d. ) (Spontaneous draining) Terminal block (Remote controller transmission line) 7 Control box Terminal block (Indoor/Outdoor connecting line) 7±mm (ctual length) Less than mm Less than 7mm Drain hose (I.D. ) <accessory> NOTE. Use M screw for the Suspension bolt (field supply).. Keep the service space for the maintenance at the bottom.. This chart indicates for PED-RP 7 J models,which have fans. PED-RP J models have fan. 4. In case of the inlet duct is used,remove the air filter (supply with the unit), then install the filter (field supply) at suction side. Model PED-RP,J PED-RP,7J PED-RP,J PED-RPJ B C D 9 94 8 9 4 44 64 7 E F 8 G 88 8 4 8 6 8 Gas pipe Liquid pipe.7 6..88 9. More than mm More than mm N-.9 Ceiling surface ccess door Make the access door at the appointed position properly for service maintenance. 6 P J K Q Kx(L-)=M Qx(R-)=S J 777 ccess door Model PED-RP,J PED-RP,7J PED-RP,J PED-RPJ H 7 J K L M N P Q R S 4 4 78. 7 4 89 49 4 99 4 4 4 7 8 48 8 H Note 4 ~ 4 More than Required space for service and maintenance

PED-RP,,, 7,, JL Unit : mm xe-.9 Suspension bolt hole 4-4x Slot 8 x(e-)=f 7 D (Duct) ir outlet ir inlet B(Suspension bolt pitch) C G ir Filter 8 7 64 (Suspension bolt pitch) Refrigerant piping Flare connection (liquid) -.9 78 (Duct) Refrigerant piping Flare connection (gas) 7 7 6 67 6 Drain pipe(o.d. ) 7 Terminal block (Remote controller transmission line) 7±mm (ctual length) Control box Terminal block (Indoor/Outdoor connecting line) Drain hose (I.D. ) <accessory> NOTE. Use M screw for the Suspension bolt (field supply).. Keep the service space for the maintenance at the bottom.. This chart indicates for PED-RP 7 JL models,which have fans. PED-RP JL models have fan. 4. In case of the inlet duct is used,remove the air filter (supply with the unit), then install the filter (field supply) at suction side. Model PED-RP,JL PED-RP,7JL PED-RP,JL PED-RPJL B C D 9 94 8 9 4 44 64 7 E F 8 G 88 8 4 8 6 8 Gas pipe Liquid pipe.7 6..88 9. More than mm More than mm N-.9 Ceiling surface ccess door Make the access door at the appointed position properly for service maintenance. 6 P J K Q Kx(L-)=M Qx(R-)=S J 777 ccess door Model PED-RP,JL PED-RP,7JL PED-RP,JL PED-RPJL H 7 J K L M N P Q R S 4 4 78. 7 4 89 49 4 99 4 4 4 7 8 48 8 H Note 4 ~ 4 More than Required space for service and maintenance 4

PED-RPE PED-RPE PED-RPE Unit : mm Model B C D E F G R4 Outdoor unit : 6. R4 Outdoor unit :.7 RP, 77-8 84 R7C Outdoor unit : 9. R7C Outdoor unit :.88 Outdoor unit (SUZ) : 6. RP 8 9 7 44.88 R7C Outdoor unit : 9. Initial setting Service space: or more 4 ~ 9 4 6 7 Refrigerant piping flare connection (liquid F copper tube):hp Refrigerant piping flare connection (gas G copper tube):lp Drain R(External thread) Electrical parts box Drain Pump (Option) Drain Pipe (Option)... Flexible joint VP-(I.D. ) Filter Set 4 ccess door 97 8 C B 8 - (RP,) - (RP) Lifting bolt hole (4 ) 6~46 9 6 In case of rear inlet ir inlet 7. 88. 6 76 Keep duct-work length 8mm or more. Be sure to apply the air filter near the air inlet grille. 4 8 6 6 7 4 9 79 ir outlet 77 4 8 8 8 6 44 7 4 C B 8 - (RP,) - (RP) E D In case of bottom inlet 7 ir outlet - (RP,) - (RP). 76 6 ir inlet 8 C B 8 PED-RP7E PED-RPE PED-RPE Service space: or more 4 ~ 9 - Model B RP7 8 RP, RP 4 Initial setting C 9 7 47 D E F 7 44.88 84 R4 Outdoor unit :.88 6 84 R7C outdoor unit : 9. 4 ccess door 97 8 C B 8 Lifting bolt hole (4x) Refrigerant piping flare connection (liquid 9. copper tube):hp Refrigerant piping flare connection (gas F copper tube):lp Drain R (External thread) 4 Electrical parts box Drain Pump (Option) Set 6 Drain Pipe (Option)... Flexible joint VP(I.D. ) 7 Filter ir inlet 7.. 9 6 8 8 68 69 ir outlet 7 6~46 8 4 6 4 44 7 4 8 C B 8 E D 7 8 - Keep duct-work length 8mm or more. Be sure to apply the air filter near the air inlet grille.

PED-RPG PED-RP7G PED-RPG Unit : mm Model RP RP7 RP 6 B 9 9 C 9 D E 7 7 9 * Initial setting F G H J 8 8 Outdoor unit(suz) : 6. Other outdoor unit : 9. *.88 8 8 8 9. 9..88 R4 Outdoor unit :.88 * R7C Outdoor unit : 9. 6

PK-RPHL PK-RPHL Unit : mm 87 9 Top side 97 99 Front side Mount board Right side 9 Left side 688 49 Knockout hole for left piping 898 Front side (Grille open) Knockout hole for right piping Sleeve (purchased locally) 6~ 8 Through hole 6~ 8 Terminal block for outdoor unit Terminal block for power supply (option) Terminal block for M-remote controller (option) 47 Gas pipe 9 Liquid pipe 6 Drain hose 69 8 84 Emergency operation switch (cooling/heating) Vane (auto) Under side 6 Operation lamp DEFROST/STND BY lamp 8 Size Refrigerant pipe : 6. Liquid pipe Flared connection : /4F Refrigerant pipe :.7 Gas pipe Flared connection : /F Drain hose 6 O.D Knockout hole for lower piping C Louver (manual) Knockout hole for lower piping B Receiver Center measurement hole. Knockout hole for piping 8.8. 6 C 46 6 4 69 6 6 4 D 4 9 77-. Tapping screw hole 8. 4 78.. 9 6 66 78.... 7. 6. 7. 9. 6 4-9 Bolt hole 7 7 Mount board 8 6 9. 7. 6. 7. Indoor unit outline.8.7. 66 8... 7. 4 6 46 B 449 Wall hole for left piping 94 78. 8 74 67 8. 9. Knockout hole for left rear piping (7 ) 8 449 Wall hole for right rear piping Min.7 mm or greater with optional drain pump installation. Required space (Indoor unit) Min. mm or greater with optional drain pump installation. Min. ir inlet ir inlet Min. ir outlet Min. Min. mm or greater with left or rear left piping or drain pump installation. 7

PK-RPKL PK-RPKL Unit : mm Top side 4.7 4.7. 6. Left side Front side Right side Knockout hole for left piping 6 Mount board C 74 (8) 4 7 9 Operation lamp DEFROST/STND BY lamp Receiver Knockout hole for right piping Front side (Grille open) Terminal block for outdoor unit 8 66 Filter hook 444 (Gas pipe) 48 (Liquid pipe) 8 (Drain hose) 4 4 Terminal block for power supply (option) Terminal block for M-remote controller (option) Emergency operation switch (cooling/heating) Under side Piping connection department Refrigerant pipe : 9. Liquid pipe Flared connection : /8F Refrigerant pipe :.88 Gas pipe Flared connection : /8F Sleeve (purchased locally) Through hole Drain hose 6 O.D 7 7~ 8 B Vane (auto) Louver (manual) Knockout hole for lower piping B C 6 Knockout hole for piping B 67 77 6 77 67.7 77 7.8 7.8 87 6 7-. Tapping screw hole. 7 7 4 9 4 79. 9 7.4 4-9 Bolt hole 44 49 8. 84 64 4 Temporarily fixing hole Center measurement hole. R7. 8. 49 4. 84 9 89 4 Mount board 4 64 84. 8. 49 44 46. Indoor unit outline 4.. 7. 6. 87. 4. 9. 67 7 9. 64 9 8. Min. 7 6 mm or greater with optional drain pump installation Required space (Indoor unit) Min. 7.4 Min. mm or greater with optional drain pump installation ir inlet ir outlet Min.. Min. 48 Min. 8 mm or greater with left or rear left piping or drain pump installation Wall hole for left rear piping Knockout hole for left rear piping (7 48) 6. 9 49. 84 Wall hole for right rear piping 49 449. 8 8

PK-RPGL PK-RPGL Unit : mm Front view Left side 7 ir intake ir intake 8 8 ir intake Right side Less than ir intake Knockout hole for right piping Refrigerant pipe. Drain pipe. Wiring hole 7 4 98 7 4 Knock out hole for left piping Refrigerant pipe.drain pipe.wiring hole. 99 uto vane llowing clearances Front view Right side er side 7 ir outlet -Louvers(manual) Knockout hole for under piping Refrigerant piping.drain pipe. Wiring hole 8 or more or more 4-4hole for bolts 49- hole for tapping screw Left-rear piping hole Knockout hole for left-rear piping Details of installation plate or more or more Installation plate balance point hole Less than (Necessary clearance for unit installation) R. R. Knockout hole for right-rear piping Unit center 4 7 9 4 49 4 9 7 9 4 49 Model, Sleeve 9 Right-rear piping hole Through hole 9~ Sleeves are available on the market. This size shows the lower end of through hole. 8 9 7 Front view(to open the grille) Filter grip R. R. (Left side piping installation) Unit drain pipe O.D. Gas pipe Liquid pipe 7 (Flexible hose total length8) 8 4 449 86 Service panel (Power supply access) Terminal block to outdoor unit Terminal block for 8 8 79 LIQUID SIDE 9 9 7 RP, P, 6. 9. 9. power supply (Heater (PKH-P, GLH only)) (Right side piping installation) Use the current nuts meeting the pipe size of the outdoor unit. vailable pipe size GS SIDE : Initial flare nut size.7.88.88 9

PK-RPFL PK-RPFL Unit : mm Top Display section 4 4 Front 4 6. Receiving section Right side Emergency switch(heat) Emergency switch(cool) Defrosting Initial heating lamp Power lamp Left side 9 ir intake Knockout hole for right piping Refrigerant pipe. Drain pipe 97 C Knockout hole for left piping Liquid pipe Terminal block for indoor/outdoor connecting line Terminal block for heater (PKH only) Gas pipe Bolt 4 8 Drain hose for left-hand side piping Drain hose 8 (Gas pipe) (Liquid pipe) 7 Drain hose O.D. ir outlet er side uto vanes ir outlet Liquid pipe 9.(/8F) Gas pipe.88(/8f) Under panel Louvers (manual) Removable at left-hand side piping Knockout hole for under-piping Refrigerant pipe. Drain pipe B Sleeve Through hole 9 9~ Sleeves are available on the market. Use the current nuts meeting the pipe size of the outdoor unit. Wall fixture 66-ø6 hole for tapping screw -ø hole for bolt Unit center 99 4 9=(9) 9 8 8 Drainage range Drainage range 9 on left-hand side on right-hand side 4 8 9 8 8 4 -ø6 hole for 6 9 tapping screw Range for left rear piping opening 84 9 8 8 Rear piping opening 4 9 B C 7 74 Knockout hole for wiring 9 98 7 6 7 74 9 4 vailable pipe size LIQUID SIDE GS SIDE RP 6. 9..7.88 RP,7 / P,7 9..88 : Initial flare nut size

PK-RPFL Unit : mm Top Display section 6. 4 4 Front Left side 68 7 ir intake 4 4 Knockout hole for right piping Receiving section Emergency switch(heat) Emergency switch(cool) Defrosting Initial heating lamp Power lamp Right side 97 C Knockout hole for left piping Liquid pipe Terminal block for indoor/outdoor connecting line Terminal block for heater (PKH only) Gas pipe Bolt Drain hose for left-hand side piping Drain hose Drain hose er side 8 694 ir outlet 694 ir outlet uto vane Louvers (manual) Under panel (Removable at left-hand side piping) 4 8 (Gas pipe) (Liquid pipe) B Drain hose O.D. vailable pipe size RP LIQUID SIDE 9. GS SIDE.88 9. :Initial flare nut size P 9. 9. Use the current nuts meeting the pipe size of the outdoor unit. Knockout hole for under-piping Refrigerant pipe. Drain pipe Unit out line Unit center 7 Wall fixture 9 9=(8) 84-ø6 hole for 8 8 9 tapping screw Drainage range Drainage range on left-hand side on right-hand side 9 4 8 9 9 Knockout hole for wiring B C 8 4-ø hole for bolt 9 8 8 4 7 9 84 8 Rear piping opening 4 9 7 74 9 98 7 6 7 74 9 4 Range for left rear piping opening Range for left rear piping opening -ø6 hole for tapping screw

OUTDOOR UNIT PUHZ-HRP7VH PUHZ-HRPVH PUHZ-HRPYH PUHZ-HRPYH Unit : mm Example of Notes Refrigerant GS pipe connection (FLRE).88(/8 inch) Refrigerant LIQUID pipe connection (FLRE) 9.(/8 inch) Indication of STOP VLVE connection location. Piping Knockout Hole Details Side ir Intake Handle for moving Handle for moving Rear ir Intake -U Shaped notched holes (Foundation Bolt M) 7 7 Side ir Intake 4 6 8 7 47 (9) Installation Feet ir Discharge 66 4 4 Power supply wiring hole (- 7Knockout) Rear trunking hole (Knockout) 6 9 Rear piping hole (Knockout) - x 6 Oval holes (Foundation Bolt M) 9 Handle for moving Earth terminal Terminal connection Left Power supply wiring Right Indoor/Outdoor wiring Service panel Handle for moving Front piping cover Rear piping cover 9 Front trunking hole (Knockout) Power supply wiring hole (- 7Knockout) 4 Right piping hole (Knockout) 7,79 9 Power supply wiring hole (- 7Knockout) Right trunking hole (Knockout) 7 6 7 9 7 6 7 9 7 7 6 8 9 7 7 6 44 447 Over Handle for moving ir intake 9 Front piping hole (Knockout) 9 6 9 9 Rear ir Intake 7 Bottom piping hole (Knockout) 4 4 4 Drain hole (- ) HRP VH HRP YH Over Over Less than FREE SPCE (round the unit) The diagram below shows a basic example. Explanation of particular details are given in the installation manuals etc. FREE SERVICE SPCE Dimensions of space needed for service access are shown in the below diagram. Over Service space FOUNDTI BOLTS 4 PIPING-WIRING DIRECTIS Please secure the unit firmly with 4 foundation (M) bolts. (Bolts and washers must be purchased locally.) Piping and wiring connections can be made from 4 directions: front, right, rear and below. <Foundation bolt height> FOUNDTI Over mm Over mm Over mm Over mm

PUHZ-HRP7VH PUHZ-HRPVH PUHZ-HRPYH PUHZ-HRPYH,79 Unit : mm Example of Notes Refrigerant GS pipe connection (FLRE).88(/8 inch) Refrigerant LIQUID pipe connection (FLRE) 9.(/8 inch) Indication of STOP VLVE connection location. Handle for moving ir intake Piping Knockout Hole Details Rear ir Intake 9 Side ir Intake Handle for moving Handle for moving Rear ir Intake -U Shaped notched holes (Foundation Bolt M) 7 7 Side ir Intake 4 6 8 7 47 (9) Installation Feet ir Discharge 66 4 4 Power supply wiring hole (- 7Knockout) Rear trunking hole (Knockout) 6 9 Rear piping hole (Knockout) - x 6 Oval holes (Foundation Bolt M) Front piping cover Rear piping cover 9 Front trunking hole (Knockout) Power supply wiring hole (- 7Knockout) 4 Right piping hole (Knockout) 7 Power supply wiring hole (- 7Knockout) Right trunking hole (Knockout) 7 6 7 9 7 6 7 9 7 7 6 8 9 7 9 Front piping hole (Knockout) 9 6 9 9 7 Bottom piping hole (Knockout) 4 4 4 Drain hole (- ) HRP VH HRP YH Over Over Less than FREE SPCE (round the unit) The diagram below shows a basic example. Explanation of particular details is given in the installation manuals etc. SERVICE SPCE Dimensions of space needed for service access are shown in the below diagram. Over Service space Over FOUNDTI BOLTS Please secure the unit firmly with 4 foundation (M) bolts. (Bolts and washers must be purchased locally.) 4 PIPING-WIRING DIRECTIS Piping and wiring connections can be made from 4 directions: front, right, rear and below. <Foundation bolt height> FOUNDTI Handle for moving 9 Earth terminal Terminal connection Left Power supply wiring Right Indoor/Outdoor wiring Handle for moving Service panel Handle for moving 7 44 447 6 Over mm FREE Over mm Over mm Over mm

4 WIRING DIGRM 4-. INDOOR UNIT PL-RPB PL-RPB PL-RPB PL-RP7B PL-RPB PL-RPB PL-RP7B PL-RPB PL-RPB PL-RPB [LEGEND] SYMBOL NME I.B INDOOR CTROLLER BORD CNL CNECTOR (LOSSNY) CN CNECTOR (REMOTE SWITCH) CN4 CNECTOR (H TERMINL-) CN CNECTOR (CENTRLLY CTROL) FUSE FUSE (T6.LV) LED POWER SUPPLY (I.B) LED POWER SUPPLY (R.B) LED TRNSMISSI (INDOOR-OUTDOOR) SW SWITCH (MODEL SELECTI) See table SW SWITCH (CPCITY CODE) See table SWE CNECTOR (EMERGENCY OPERTI) X RELY (DRIN PUMP) DCL RECTOR DP DRIN PUMP FS DRIN FLOT SWITCH Refer to tables and TB6 I-SEE WIRELESS I-SEE SENSOR SENSOR MOTOR CN9 CN4Y CN6Y UTO GRILLE () CNG 9 4 6 () UTO GRILLE POWER CNC TB TRNSMISSI WIRES DCV I.B R.B VNE CNV J4 J4 CN 8 6 4 8 6 4 SW SW 9 7 9 7 Pair No. CN CN4 CNL LED LED LED 4 SWE SYMBOL NME MF FN MOTOR MV VNE MOTOR TB TERMINL BLOCK (Indoor unit Power (option)) TB4 TERMINL BLOCK (INDOOR/OUTDOOR CNECTING LINE) TB,TB6 TERMINL BLOCK (REMOTE CTROLLER TRNSMISSI LINE) TH ROOM TEMP. THERMISTOR ( / k, /. 4k DETECT) TH PIPE TEMP. THERMISTOR/LIQUID ( / k, /. 4k DETECT) TH CD. / EV. TEMP. THERMISTOR ( / k, /. 4k DETECT) OPTI PRT W.B PCB FOR WIRELESS REMOTE CTROLLER BZ BUZZER LED LED (OPERTI INDICTI : GREEN) LED LED (PREPRTI FOR HETING : ORNGE) RU RECEIVING UNIT SW SW EMERGENCY OPERTI (HET / DOWN) EMERGENCY OPERTI (COOL / UP) FLOT SW CN4F 4 INDOOR/OUTDOOR COMMUNICTI CNC (BLU) REMOC CN (BLU) LIQUID/PIPE CN44 4 INTKE CN () + <Table > SW (MODEL SELECTI) SW MODELS SETTING PL-RP B 4 PL-RP7//B PL-RPB PL-RPB <Table > SW (CPCITY CODE) SW CPCITY SETTING CPCITY SETTING 4 4 4 4 4 7 4 4 The black square ( ) indicates a switch position. OUTDOOR CN () FUSE X FN CNMF D.U.M 7 4 CNP (BLU) YLW 4 4 DCL YLW ORN Please set the voltage using the remote controller. For the setting method,please refer to the indoor unit Installation Manual. ORN BRN TB4 YLW S ORN S S TO OUTDOOR UNIT M M M M MV MV MV MV 9 CNB SW SW RU BZ LED LED 4 t t t FS TH TH TH I-SEE M SENSOR U.B MT I-SEE SENSOR CORNER PNEL (OPTI PRT) CNG CN UTOMTIC FILTER ELEVTI PNEL (OPTI PRT) MS ~ MF M ~ DP Be sure to turn off the source power and then disconnect fan motor connector. (Failure to do so will cause trouble in Fan motor) GRILLE W.B Notes:.SymboIs used in wiring diagram above are, : Connector, : Terminal (block)..indoor and outdoor connecting wires have poiarities, make sure to match terminal numbers (S, S, S) for correct wirings..since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring diagram for servicing. 4.This diagram shows the wiring of indoor and outdoor connecting wires.(specification of V), adopting superimposed system for power and signal. :If indoor and outdoor units have separate power supplies, refer to Fig.. :For power supply system of this unit, refer to the caution label located near this diagram. (Fig. ) CN () I.B CNC (BLU) I.B YLW ORN BLU GRN/YLW INDOOR/OUTDOOR COMMUNICTI TB L N YLW TB4 ORN S ORN S BRN S POWER SUPPLY ~(PHSE) V Hz TO OUTDOOR UNIT 4

PED-RPJ(L) PED-RPJ(L) PED-RPJ(L) PED-RP7J(L) PED-RPJ(L) PED-RPJ(L) INSIDE SECTI OF CTROL BOX TB TO M REMOTE CTROLLER CN9 LED CNC (Blue) CN44 4 4 4 SW SW SW CN4F SW6 SWE (Red) CN 4 CN4 CN4F B CN (Red) CNL CN t TH LED CNXB CNXC CN (Red) CN (Black) CN (Blue) LED I.B. (Blue) CNX 4 (Blue) CNP U CNXB 4 ZNR X DS ZNR U CNXC F (Blue) CNX CND (Red) X 4 P.B. DC8-V Rectifier circuit CNMF 7 6 4 CL TB4 S S S TO OUTDOOR UNIT <Table > SW (MODEL SELECTI) <Table > SW (CPCITY CODE) SW CPCITY SETTING CPCITY SETTING MODELS PED-RP J(L) 4 4 4 4 7 SW 4 SW 4 4 4 4 The black square ( ) indicates a switch position. 6 7 8 SW6 t t TH TH FS FOR PED-RP J REFER TO "B" FOR PED-RP JL I.B. Indoor controller board I.B. Connector (-V nalog input) Connector (Lossnay) Connector (Remote switch) Connector (H terminal-) Connector (Centrally control) P.B. CN CNL CN CN4 CN CN9 CN LED LED LED Connector (Wireless) Connector (IT terminal) LED(Power supply) LED(Remote controller supply) LED(Transmission indoor-outdoor) SW SW SW SW6 SWE F ZNR, DS X X Indoor controller board Switch (for model selection) Switch (for capacity code) Switch (for model selection) Switch (for model selection) Connector (emergency operation) Power supply board Fuse CV 6. Varistor rrester ux. relay ux. relay M ~ Drainpump TH TH TH CL FS TB4 TB LY FOR PED-RP J SYMBOL NME SYMBOL NME SYMBOL NME SYMBOL EXPLNTI MS ~ Fan motor Intake air temp. Thermistor Pipe temp. Thermistor/liquid Cond./eva.temp. Thermistor C reactor (Power factor improvement) Float switch Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) NOTE:. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring for servicing.. Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (S,S,S).. Symbols used in wiring diagram above are, terminal block, connector. TO CND < > (IN CSE OF CNECT CL THE REPLCEMENT WIRING) TO CNC L N S S S POWER SUPPLY ~ (PHSE) -V Hz TO OUTDOOR UNIT

PED-RPE PED-RPE PED-RPE PED-RP7E PED-RPE PED-RPE [LEGEND] SYMBOL NME SYMBOL NME SYMBOL NME I.B. INDOOR CTROLLER BORD SW SWITCH(CPCITY CODE) TB4 TERMINL BLOCK FUSE FUSE(T6.LV) SWE SWITCH(EMERGENCY OPERTI) (INDOOR/OUTDOOR CNECTING LINE) ZNR VRISTOR X RELY(DRIN PUMP) TB TERMINL BLOCK(REMOTE CTROLLER) CNL CNECTOR(LOSSNY) X4 RELY(FN MOTOR) TH INTKE IR TEMP. THERMISTOR CN4 CNECTOR(HETER) X RELY(FN MOTOR) ( /kω, /.4kΩ DETECT) CN CNECTOR(REMOTE SWITCH) CN4 CNECTOR(H TERMINL-) X6 P.B. RELY(FN MOTOR) INDOOR POWER BORD TH PIPE TEMP. THERMISTOR/LIQUID ( /kω, /.4kΩ DETECT) CN CNECTOR(CENTRLLY CTROL) DRIN PUMP (OPTIL PRTS) TH CD./EV. TEMP. THERMISTOR CN9 CNECTOR(WIRELESS) DP DRIN PUMP ( /kω, /.4kΩ DETECT) LED POWER SUPPLY(I.B.) DS DRIN SENSOR LED POWER SUPPLY(REMOTE CTROLLER) C CPCITOR(FN MOTOR) LED TRNSMISSI(INDOOR OUTDOOR) MF FN MOTOR SW SWITCH(MODEL SELECTI) INSIDE SECTI OF CTROL BOX DS TH TH TH B B L L U U CN I.B. 4 6 7 8 9 4 4 CN CN CN CN9 CN CN9 CN4 CN4 CN CN (BLU) () () (YLW) WHT LED LED LED CND (BLU) CNC O B RN R N CNL () FUSE (ORN) CND O Y RN L W ZNR () CNDK W B HT L K X X (BLU) CNP X4 X X6 X W HT X4 7 P N K P NK B LK X6 FN SW SW SWE <PED-RP E, E> External static pressure Pa TO M-REMOTE CTROLLER DC8.7-V TO OUTDOOR UNIT TB B L U B L U TB4 S BRN S ORN S YLW W B W B HT L HT L K K P.B. CNS CNSK () DP Optional parts <PED-RP E, E> External static pressure 7Pa () 4 6 4 6 MF C <PED-RP7 E, E> External static pressure 7Pa Optional parts 4 6 () MF C <PED-RP7 E, E> External static pressure Pa SW MODELS Model selection switch E() E E 7E E() E E 4 SW Capacity cord switch 4 4 4 4 4 4 4 The black square ( ) indicates a switch position. < > TO CND (IN CSE OF CNECTING THE REPLCEMENT WIRING) TO CNC L N S S S POWER SUPPLY ~(PHSE) V Hz TO OUTDOOR UNIT Notes:. SymboIs used in wiring diagram above are, : Connector, : Terminal (block).. Indoor and outdoor connecting wires have poiarities, make sure to match terminal numbers (S, S, S) for correct wirings.. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring diagram for servicing. 4. This diagram shows the wiring of indoor and outdoor connecting wires (specification of V), adopting superimposed system for power and signal. : If indoor and outdoor units have separate power supplies, refer to. : For power supply system of this unit, refer to the caution label located near this diagram. 6

PED-RPG PED-RP7G PED-RPG [LEGEND] SYMBOL NME I.B. INDOOR CTROLLER BORD FUSE FUSE(T6.LV) ZNR VRISTOR CNL CNECTOR(LOSSNY) CN4 CNECTOR(HETER) CN CNECTOR(REMOTE SWITCH) CN4 CNECTOR(H TERMINL-) CN CNECTOR(CENTRLLY CTROL) CN9 CNECTOR(WIRELESS) LED POWER SUPPLY(I.B.) LED POWER SUPPLY(REMOTE CTROLLER) LED TRNSMISSI(INDOOR OUTDOOR) SYMBOL NME SW SWITCH(MODEL SELECTI) SW SWITCH(CPCITY CODE) SWE SWITCH(EMERGENCY OPERTI) X RELY(DRIN PUMP) X4 RELY(FN MOTOR) X RELY(FN MOTOR) X6 RELY(FN MOTOR) P.B. INDOOR POWER BORD C CPCITOR(FN MOTOR) MF FN MOTOR TB4 TERMINL BLOCK (INDOOR/OUTDOOR CNECTING LINE) SYMBOL NME TB TERMINL BLOCK(REMOTE CTROLLER) TH INTKE IR TEMP.THERMISTOR ( /kω, /.4kΩ DETECT) TH PIPE TEMP. THERMISTOR/LIQUID ( /kω, /.4kΩ DETECT) TH CD./EV. TEMP. THERMISTOR ( /kω, /.4kΩ DETECT) INSIDE SECTI OF CTROL BOX TH TH TH B B L L U U 4 6 7 8 9 4 4 I.B. CN CN CN CN9 CN CN9 CN4 CN4 CN CN (BLU) () () (YLW) SW WHT LED LED LED CND CNL () ZNR X X X4 X4 X X X6 X6 SW SWE (BLU) CNC O B RN R N FUSE (ORN) CND O Y RN L W () CNDK W B HT L K (BLU) CNP 7 FN G Y Y B RY L L L W W K TO M-REMOTE CTROLLER DC8.7-V TO OUTDOOR UNIT TB B L U B L U TB4 S BRN S ORN S YLW W B W B HT L HT L K K P.B. B B O L L R U K G CNS CNSK 4 6 () MF C * *External static pressure CNECTOR COLOR V BLU Pa WHT (INITIL SETTING) Pa Pa V Pa Pa 7Pa V Pa Pa 7Pa < > TO CND (IN CSE OF CNECT THE REPLCEMENT WIRING) TO CNC L N S S S POWER SUPPLY ~(PHSE) V Hz TO OUTDOOR UNIT MODELS G 7G G SW Model selection switch 4 SW Capacity cord switch 4 4 4 The black square ( ) indicates a switch position. Notes:. SymboIs used in wiring diagram above are, : Connector, : Terminal (block).. Indoor and outdoor connecting wires have poiarities, make sure to match terminal numbers (S, S, S) for correct wirings.. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring diagram for servicing. 4. This diagram shows the wiring of indoor and outdoor connecting wires (specification of V), adopting superimposed system for power and signal. : If indoor and outdoor units have separate power supplies, refer to. : For power supply system of this unit, refer to the caution label located near this diagram. 7

PK-RPHL PK-RPHL [Explanation of symbols] Symbol Name Symbol Name I.B Indoor controller board M Vane motor CNL Connector (LOSSNY) MS Fan motor CN Connector ( Remote switch) S.W Switch board CN4 Connector (H terminal-) SWE Emergency operation CN Connector (Centrally control) TB Terminal block(indoor unit Power (option)) CN9 Connector (Remote operation adapter) TB4 Terminal block (Indoor/outdoor connecting line) FUSE FUSE(T.LV) TB Terminal block (Remote controller transmission line(option)) LED Power supply (I.B) TH Room temp. Thermistor LED Power supply (R.B) ( /kω, /.4kΩ Detect) LED Transmission (Indoor-outdoor) TH Pipe temp. Thermistor/liquid SW Switch (Model selection) See table ( /kω, /.4kΩ Detect) SW SWE Switch (Capacity code) See table Connector (Emergency operation) TH Cond./eva. temp. Thermistor ( /kω, /.4kΩ Detect) X Relay (Drain pump (option)) W.B PCB for wireless remote controller CNP Drain pump (option) power supply (Drain pump (option)) LED LED (Operation indication : Green) CN4F Drain float switch (Drain pump (option)) LED LED (Preparation for heating: Orange) R.B Wired remote controller(option) REC Receiving unit TB6 Terminal block (Remote controller transmission line) DCL RECTOR DP DRIN PUMP (OPTI) FS DRIN FLOT SWITCH (OPTI) Refer to tables and I.B SWE CN CN () T LED LED LED DB CN9 9 CN 4 CNL () CN4 CN CN44 CN4F 4 4 MS ~ CNMF 6 FUSE CN () DP M X ~ CNP(BLU) S.W CNC ORN BRN (BLU) LDSWE(B) SWE LDSWE() W.B (BLU) 6 CNRU RU LD(B) REC CN (BLU) DCL YLW YLW ORN LED TB4 YLW S ORN S S LED TO OUTDOOR UNIT <Table > SW (MODEL SELECTI) SETTING 4 <Table > SW (CPCITY CODE) MODELS SETTING 4 RP BLU BLU TB RP R.B TB6 4 The black square ( ) indicates a switch position. (OPTI PRTS) M t t t TH TH TH When attaching drain pump(option), remove the jumper connector CN4F and fit the drain float switch (FS). When attaching drain pump (option) FLOT SW CN4F 4 FS (Fig. ) CN () I.B YLW ORN TB L BLU N GRN/YLW POWER SUPPLY ~(PHSE) V Hz Notes:. SymboIs used in wiring diagram above are, : Connector, : Terminal (block).. Indoor and outdoor connecting wires have poiarities, make sure to match terminal I.B numbers (S, S, S) for correct wirings.. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring diagram for servicing. 4. This diagram shows the wiring of indoor and outdoor connecting wires. (specification of V), adopting superimposed system for power and signal. : If indoor and outdoor units have separate power supplies, refer to Fig. : For power supply system of this unit, refer to the caution label located near this diagram. CNC(BLU) YLW ORN ORN BRN TB4 S S S INDOOR/OUTDOOR COMMUNICTI TO OUTDOOR UNIT 8

PK-RPKL PK-RPKL [LEGEND] SYMBOL NME SYMBOL I.B Indoor controller board M CNL Connector (LOSSNY) MS CN Connector (Remote switch) S.W CN4 Connector (H terminal-) SWE CN Connector (Centrally control) TB CN9 Connector (Remote operation adapter) TB4 FUSE FUSE (T.LV) TB LED Power supply (I.B) TH LED Power supply (R.B) LED Transmission (Indoor-outdoor) TH SW Switch (Model selection) See table SW Switch (Capacity code) See table TH SWE Connector (Emergency operation) X Relay (Drain pump(option)) W.B CNP Drain pump (option) power supply (Drain pump(option)) LED CN4F Drain float switch (Drain pump (option)) LED R.B Wired remote controller REC TB6 Terminal block (Remote controller transmission line) DCL DP FS NME Vane motor Fan motor Switch board Emergency operation Terminal block (Indoor unit Power (option)) Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) Room temp. Thermistor ( / k, /. 4k Detect) Pipe temp. Thermistor/liquid ( / k, /. 4k Detect) Cond. / eva. temp. Thermistor ( / k, /. 4k Detect) PCB for wireless remote controller LED (Operation indication : Green) LED (Preparation for heating : Orange) Receiving unit RECTOR DRIN PUMP (OPTI) DRIN FLOT SWITCH (OPTI) MF (Fig. ) CN () I.B YLW ORN BLU GRN/YLW TB L N POWER SUPPLY ~(PHSE) V Hz I.B CNC (BLU) YLW TB4 ORN S ORN S BRN S INDOOR/OUTDOOR COMMUNICTI TO OUTDOOR UNIT The black square ( ) indicates a switch position. Notes:. SymboIs used in wiring diagram above are, :Connector, : Terminal (block).. Indoor and outdoor connecting wires have poiarities, make sure to match terminal numbers (S, S, S) for correct wirings.. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring diagram for servicing. 4. This diagram shows the wiring of indoor and outdoor connecting wires.(specification of V), adopting superimposed system for power and signal. If indoor and outdoor units have separate power supplies, refer to Fig. For power supply system of this unit, refer to the caution label located near this diagram. 9

PK-RPGL PK-RPGL [LEGEND] SYMBOL NME P.B INDOOR POWER BORD I.B INDOOR CTROLLER BORD FUSE FUSE (T6.LV) ZNR VRISTOR CNL CNECTOR <LOSSNY> CN CNECTOR <REMOTE SWITCH> CN4 CNECTOR <H TERMINL-> CN CNECTOR <CENTRLLY CTROL> SW SWITCH <MODEL SELECTI> See Table. SW SWITCH <CPCITY CODE> See Table. SWE SWITCH <EMERGENCY OPERTI> X4 RELY <FN MOTOR> BCR FN CTROL ELEMENT LED POWER SUPPLY <I.B> LED POWER SUPPLY <R.B> LED TRNSMISSI <INDOOR-OUTDOOR> SYMBOL C MF MV TB TB4 TB,TB6 TH TH TH NME CPCITOR <FN MOTOR> FN MOTOR VNE MOTOR TERMINL BLOCK (HETER) PKH-P.GLH models only or option for PK-RP.GL models. TERMINL BLOCK <INDOOR/ OUTDOOR CNECTING LINE> TERMINL BLOCK <REMOTE CTROLLER TRNSMISSI LINE> <OPTI> ROOM TEMP.THERMISTOR < / k, /.4k DETECT> PIPE TEMP.THERMISTOR/ LIQUID < / k, /.4k DETECT> CD./ EV.TEMP.THERMISTOR < / k, /.4k DETECT> SYMBOL NME W.B WIRELESS REMOTE CTROLLER BORD RU RECEIVING UNIT BZ BUZZER LED LED <RUN INDICTOR> LED LED <HOT DJUST> SW SWITCH (HETING / > SW SWITCH (COOLING / > R.B WI REMOTE CTROLLER BORD HETER FS THERML FUSE <4 > FS THERML FUSE <84 > H HETER 6H HETER THERML SWITCH 88H HETER CTCTOR I.B FN BCR SWE I.B MF C WHT SW X4 X4 Refer to tables and for service PCB. YLW YLW HETER CN4 (YLW) 6 6 GRY 88H P.B CNDK () DC.V WHT YLW ORN CNS POWER POWER VNE CNDK CND CN6V () (ORN) POWER INDOOR/OUTDOOR (GRN) CND COMMUNICTI CNC(BLU) ZNR CN4 CNL WIRELESS CN9 CN CN LED LED LED SW INTKE LIQUID PIPE REMOC CN CN CN9 CN () () (BLU) 6H H FUSE TH WHT TH TH PKH-P,GLH models only FS YLW ORN ORN BRN FS 88H TB L WHT BLU N GRN/YLW TB4 S S S 6 TO OUTDOOR UNIT MV YLW ORN I.B POWER CND (ORN) 9 TRNSMISSI WIRES DCV TB POWER SUPPLY ~(PHSE) V Hz (Fig.) TB L BLU N GRN/YLW INDOOR/OUTDOOR COMMUNICTI CNC (BLU) RU RECEIVER YLW TB4 S ORN ORN S BRN S BZ LED LED SWSW W.B R.B CNB POWER SUPPLY ~(PHSE) V Hz TO OUTDOOR UNIT TB6 Please set the voltage using the remote controller. For the setting method, please refer to the indoor unit Installation Manual. SW Service board 4 MODELS PK-RPGL PKH-PGLH SW Service board MODELS 4 The black square ( ) indicates a switch position. PK-RPGL PKH-PGLH Service board 4 Notes:. SymboIs used in wiring diagram above are, : Connector, : Terminal (block).. Indoor and outdoor connecting wires have poiarities, make sure to match terminal numbers (S, S, S) for correct wirings.. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring diagram for servicing. 4. This diagram shows the wiring of indoor and outdoor connecting wires (specification of V), adopting superimposed system for power and signal. : If indoor and outdoor units have separate power supplies, refer to Fig. : For power supply system of this unit, refer to the caution label located near this diagram.

PK-RPFL PK-RPFL PK-RPFL [LEGEND] SYMBOL NME P.B INDOOR POWER BORD I.B INDOOR CTROLLER BORD FUSE FUSE(T6.LV) ZNR VRISTOR CNL CNECTOR(LOSSNY) CN CNECTOR(REMOTE SWITCH) CN4 CNECTOR(H TERMINL-) CN CNECTOR(CENTRLLY CTROL) SW SWITCH (MODEL SELECTI) See Table. SW SWITCH (CPCITY CODE) See Table. SWE SWITCH(EMERGENCY OPERTI) X4 RELY(FN MOTOR) BCR FN CTROL ELEMENT LED POWER SUPPLY(I.B) LED POWER SUPPLY(R.B) LED TRNSMISSI(INDOOR-OUTDOOR) SYMBOL C MF MV TB TB4 TB TH TH TH NME CPCITOR(FN MOTOR) FN MOTOR VNE MOTOR TERMINL BLOCK (HETER) PKH-P.FLH models only or option for PK-RP.FL models. TERMINL BLOCK(INDOOR/OUTDOOR CNECTING LINE) TERMINL BLOCK(REMOTE CTROLLER TRNSMISSI LINE )(OPTI) ROOM TEMP.THERMISTOR ( /k, /.4k DETECT) PIPE TEMP.THERMISTOR/LIQUID ( /k, /.4k DETECT) CD./EV.TEMP.THERMISTOR ( /k, /.4k DETECT) SYMBOL NME W.B WIRELESS REMOTE CTROLLER BORD RU RECEIVING UNIT BZ BUZZER LED LED(RUN INDICTOR ) LED LED(HOT DJUST) SW SWITCH(HETING /) SW SWITCH(COOLING /) R.B WI REMOTE CTROLLER BORD(OPTI) TB6 TERMINL BLOCK(REMOTE CTROLLER TRNSMISSI LINE) HETER FS, H 6H 88H THERML FUSE(7 :,7FLH/ 7 6:FLH) HETER HETER THERML SWITCH HETER CTCTOR I.B FN BCR SWE MF C WHT SW X4 X4 Refer to tables and for service PCB. P.B CNDK () DC.V WHT YLW ORN POWER POWER VNE CNDK CND CN6V () (ORN) POWER INDOOR/OUTDOOR (GRN) CND COMMUNICTI CNC(BLU) ZNR CN4 CNL WIRELESS CN9 CN CN LED LED LED SW INTKE LIQUID PIPE REMOC CN CN CN9 CN () () (BLU) Table SW Service board 4 Table MODELS PK-RPFL PK-RPFL PKH-PFLH CNS FUSE TH WHT TH Please set the voltage using the remote controller. For the setting method, please refer to the indoor unit Installation Manual TH TB4 YLW S ORN S ORN S BRN 6 TO OUTDOOR UNIT MV YLW ORN I.B POWER CND (ORN) 9 TRNSMISSI WIRES DCV TB (Fig.) TB L BLU N GRN/YLW INDOOR/OUTDOOR COMMUNICTI CNC (BLU) RU RECEIVER SW Service board MODELS Service board MODELS Service board 4 The black square ( ) indicates a switch position. PKH-P PK-RP7FL PKH-P7FLH 4 PFLH models only PK-RPFL PKH-PFLH 4 YLW TB4 S ORN ORN S BRN S BZ LED LED SWSW W.B R.B CNB POWER SUPPLY (PHSE) V Hz TO OUTDOOR UNIT TB6 I.B YLW YLW HETER CN4 (YLW) 6 6 GRY 88H 6H H FS FS WHT 88H GRN/YLW TB L BLU N POWER SUPPLY (PHSE) V Hz Notes:. SymboIs used in wiring diagram above are, : Connector, : Terminal (block).. Indoor and outdoor connecting wires have poiarities, make sure to match terminal numbers (S, S, S) for correct wirings.. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring diagram for servicing. 4. This diagram shows the wiring of indoor and outdoor connecting wires (specification of V), adopting superimposed system for power and signal. : If indoor and outdoor units have separate power supplies, refer to Fig. : For power supply system of this unit, refer to the caution label located near this diagram.

4-. OUTDOOR UNIT PUHZ-HRP7VH [LEGEND] SYMBOL TB MC MF, MF S4 6H 6L SV TH,TH,TH TH4 TH6 TH7 TH8 LEV-, LEV-B,LEV-C DCL CTM CB CY,CY PUHZ-HRPVH NME SYMBOL NME SYMBOL NME Terminal Block<Power Supply, Indoor/Outdoor> Motor for Compressor Fan Motor Solenoid Valve (Four-Way Valve) Pressure Switch P.B. TBU/V/W TBS/T TBP/P/P TBN/N/N Power Circuit Board Connection Terminal<U/V/W-Phase> Connection Terminal <L/N-Phase> Connection Terminal<DC Voltage> Connection Terminal<DC Voltage> SW6 SW7 SW8 SW9 SWP Switch<Model Select> Switch<Function Setup> Switch<Function Setup> Switch Switch<Pump Down> Pressure Switch DS, DS Diode Bridge CN Connector<Emergency Operation> Solenoid Valve (Bypass Valve) IPM Power Module SS Connector<Connection for Option> Thermistor<Outdoor Pipe> Thermistor<Discharge> Thermistor<Outdoor -Phase Pipe> Thermistor<Outdoor> Thermistor<Heatsink> Electronic Expansion Valve Reactor ctive Filter Module Main Smoothing Capacitor Capacitor N.F. LI / LO NI / NO EI, E C C.B. SW SW4 SW Noise Filter Circuit Board Connection Terminal<L-Phase> Connection Terminal<N-Phase> Connection Terminal<Ground> C Relay Controller Circuit Board Switch<Forced Defrost, Defect History Record Reset, Refrigerant ddress> Switch<Test Operation> Switch<Function Switch> CNM Connector<-Control Service Inspection Kit> CNMNT Connector <Connected to Optional M-NET dapter Board> CNVMNT Connector <Connected to Optional M-NET dapter Board> CNDM Connector < Connected for Option (Contact Input)> LED,LED LED<Operation Inspection Indicators> F~F4 Fuse< T6.LV> X,X,X Relay C. B. MF MS ~ MF MS ~ 7 7 CNDC (PNK) CNF CNF CNS TH TH TH7 TH6 TH TH4 t TH (YLW) TRNS t 4 TH TH7/6 TH TH4 () () F F t t t t CNC 4 6H 6L 6H () (YLW) CN 7 F F4 6L 7 LEV- M 6 LEV- LED LED CN4 LEV-B M 6 LEV-B () X LEV-C M 6 LEV-C (BLU) CNVMNT CNM X CNMNT 4 CNC () SW SW8 SW4 SWP X S4 SV SS (GRN) (BLU) SW6 SW CN SW7 SW9 CNDM CN When M-NET adapter is connected B S TB7 M-NET SW CN SW LED SW LED LED4 M-NET SUBSTRTE CNM LED LED CND S4 SV WHT BLU N. F. LO NO P. B. C CNC () 4 7 TH8 t WHT CB CNF 6 CN 7 CN CN () CN4 TBN TBP TBP IPM TBU TBV TBW CNDC (PNK) TBN U TBN DS DS TBT BLU TBS WHT TBP CNC () CNC E CN () WHT U V W MS ~ MC WHT LI U NI U BLU EI M-NET DPTER SYMBOL TB7 CN CND CNM SW SW SW LED LED LED LED4 LED NME Terminal Block<M-net connection> Connector<Transmission> Connector<Power Supply> Connector<M-NET communication> Switch<Status of communication> Switch<ddress setting : st digit> Switch<ddress setting : nd digit> LED<Power Supply : DCV> LED<Connection to Outdoor Unit> LED<Transmission : Sending> LED<Transmission : Recelving> LED<Power Supply : DCV> DCL L CTM WHT 4 L 6 P N N Io WHT BLU L N S S S POWER SUPPLY ~/N V Hz YLW GRN/YLW ORN BRN INDOOR UNIT CY CY TB MODEL SELECT The black square ( ) indicates a switch position. MODEL 7V V SW6 4678 4678 SW-6 46 46

PUHZ-HRPYH PUHZ-HRPYH [LEGEND] SYMBOL NME SYMBOL NME SYMBOL NME TB Terminal Block<Power Supply> P.B. Power Circuit Board C.B. Controller Circuit Board TB Terminal Block<Indoor/Outdoor > TB-U/V/W Connection Terminal<U/V/W-Phase> SW Switch<Forced Defrost, Defect History Record MC Motor for Compressor TB-L/L/L Connection Terminal<L/L/L-Power Supply> Reset, Refrigerant dress> MF, MF Fan Motor TB-P Connection Terminal SW4 Switch<Test Operation> S4 Solenoid Valve (Four-Way Valve) TB-C Connection Terminal SW Switch<Function Switch> 6H Pressure Switch TB-N Connection Terminal SW6 Switch<Model Select> 6L Pressure Switch X C Relay SW7 Switch<Function Setup> SV Solenoid Valve (Bypass Valve) N.F. Noise Filter Circuit Board SW8 Switch<Function Setup> TH,TH,TH Thermistor<Outdoor Pipe> LI/LI/LI/NI Connection Terminal<L/L/L/N-Power Supply> SW9 Switch TH4 Thermistor<Discharge> LO/LO/LO/NO Connection Terminal<L/L/L/N-Power Supply> SWP Switch<Pump Down> TH6 Thermistor<Outdoor -Phase Pipe> GD, GD Connection Terminal<Ground> CN Connector<Emergency Operation> TH7 Thermistor<Outdoor> CV.B. Converter Circuit Board LED, LED LED<Operatiion Inspection Indicators> LEV-, LEV-B, LEV-C Electronic Expansion Valve L-/IN Connection Terminal<L-Power Supply> F~F4 Fuse<T6.LV> CL~CL4 Reactor L-/OU Connection Terminal<L-Power Supply> CNM Connector<-Control Service Inspection Kit> CB, CB Main Smoothing Capacitor L-/OU Connection Terminal<L-Power Supply> CNMNT Connector CK Capacitor L-/OU Connection Terminal<L-Power Supply> <Connect to Optional M-NET dapter Board> CY, CY Capacitor N-IN Connection Terminal CNVMNT Connector RS Rush Current Protect Resistor CK-OU Connection Terminal <Connect to Optional M-NET dapter Board> CNDM Connector M-NET DPTER < Connection for Option(Contact Input)> TB7 Terminal Block<M-NET connection > SW Switch<ddress setting. nd digit > CNS Connector< Connection for Option> CN Connector<Transmission> LED LED<Power Supply: DCV> CN Connector< Connection for Option> CND Connector<Power Supply> LED LED<Connection to Outdoor Unit> SS Connector< Connection for Option> CNM Connector<M-NET communication> LED LED<Transmission: Sending> X,X,X Relay SW Switch<Status of communication> LED4 LED<Transmission: Receiving> SW Switch<ddress setting: st digit> LED LED<Power Supply: DCV> MF MS ~ MF MS ~ C.B. CNS CNF 7 CNF 7 CNDC (PNK) F F 6H TH TH TH7 TH6 TH TH4 t TRNS t CNC 4 t t t t 4 TH TH TH7/6 TH TH4 (YLW) () () CN F F4 6H (YLW) 7 7 6L 6L () LEV- M 6 LEV- LED X 6 LEV-B () LED LEV-B M X LEV-C S4 SV (GRN) (BLU) M CNVMNT CNMNT CNM 4 6 LEV-C (BLU) CN4 X SS SW SW8 SW4 SWP SW6 SW CN CNDM CNS CN SW7 SW9 When M-NET adapter is connected) CN LED B S TB7 LED LED4 SW SW SW M-NET SUBSTRTE CND CNM LED M-NET LED INDOOR UNIT CY TB S S S CN7 CN4 CN () CN 7 + -- + -- TB-P + TB-C + TB-V TB-N + + CB CB CK TB-W TB-U TB-L TB-L TB-L WHT WHT W MC V MS U ~ L-OU L- L- L-OU L-IN N-IN L- L-OU CK-OU L- CY BRN ORN YLW BLU RS P.B. 7 X S4 WHT SV MODEL SELECT The black square ( ) indicates a switch position. SW6 SW-6 MODEL Y Y 4678 4678. SW - to : Function Switch WHT WHT CN7 CV.B. 46 46 N.F. POWER SUPPLY N~ V Hz NO FUSE BREKER TB L L L N WHT BLU LI LI U LI NI U U U CNC CNCT () CNC () LO LO LO NO WHT BLU BLU CL CL CL GRN/YLW U GD GD CNDC (PNK) + WHT WHT + U -- CNL (BLU) CL4

PUHZ-HRP7VH PUHZ-HRPVH [LEGEND] SYMBOL TB MC MF, MF S4 6H 6L 6HS TH TH4 TH6 TH7 TH TH LEV-, LEV-B,LEV-C DCL CE CY,CY NME SYMBOL NME SYMBOL NME Terminal Block<Power Supply, Indoor/Outdoor> P.B. Power Circuit Board CN Connector<Emergency Operation> Motor for Compressor U/V/W Connection Terminal<U/V/W-Phase> SV Connector<Connection for Option> Fan Motor LI Connection Terminal <L-Phase> SS Connector<Connection for Option> Solenoid Valve (Four-Way Valve) NI Connection Terminal<N-Phase> CNM Connector<-Control Service Inspection Kit> Pressure Switch DCL, DCL Recator CNDM Connector Pressure Switch IGBT Power Module < Connected for Option (Contact Input)> Pressure Sensor E,E,E,E4 Connection Terminal (Ground) LED,LED LED<Operation Inspection Indicators> Thermistor<Liquid> C.B. Controller Circuit Board F~F4 Fuse< T6.LV> Thermistor<Discharge> SW Switch<Manual Defrost, Defect History Record X,X,X4 Relay Thermistor<-Phase> Reset, Refrigerant ddress> Thermistor<mbient> SW4 Switch<Test Operation> M-NET DPTER Thermistor<Suction> SW Switch<Function Switch, Model Select> SYMBOL Thermistor<Ref. check> SW6 Switch<Model Select> Electronic Expansion Valve SW7 Switch<Function Set up> Reactor SW8 Switch<Function Set up> Main Smoothing Capacitor SW9 Switch<Function Switch> Capacitor SWP Switch<Pump Down> TB7 CN CND CNM SW SW SW LED LED LED LED4 LED NME Terminal Block<M-NET connection> Connector<Transmission> Connector<Power Supply> Connector<M-NET communication> Switch<Status of communication> Switch<ddress setting : s digit> Switch<ddress setting : s digit> LED<Power Supply : DCV> LED<Connection to Outdoor Unit> LED<Transmission : Sending> LED<Transmission : Receiving> LED<Power Supply : DCV> MF MS ~ MF MS ~ C.B. 7 7 CNS CNF CNF CNDC (PNK) 6HS 6H 6L TH TH TH7 TH6 TH TH4 F F t 4 TH TH TH7/6 TH TH4 6HS (YLW) () () 6L () 6H (YLW) TRNS t t CNC 4 t t t CN 7 7 F F4 LED LEV- M LEV- LED CN4 S4 (GRN) S4 6 X LEV-C M LEV-B M LEV-B () 6 CNVMNT CNMNT CNM 4 CNC () 6 LEV-C (BLU) X4 SW SW8 SW4 SWP SV (GRY) X SW SW6 CN CNDM SW9 SW7 CN SS When M-NET adapter is connected SW CN SW LED SW LED LED4 M-NET DPTER CNM CND LED LED B S TB7 M-NET P. B. CN4 CN 7 CNC () C CE WHT N P CNDC (PNK) IGBT C E E CNC () E4 CNC WHT W V U WHT W V U MS ~ MC DCL DCL DCL Setting of the starting ambient temp. of the flash injection. The black square ( ) indicates a switch position. mbient temp. C or less (lnitial setting) SW9-,4 4 4 4. SW9- to : Function Switch mbient temp. C or less SW9-,4 4 4 BLU EI POWER SUPPLY ~/N V Hz GRN/YLW YLW NI L N S S S mbient temp. - C or less U U ORN BRN INDOOR UNIT SW9-,4 4 4 LI CY CY TB MODEL SELECT The black square ( ) indicates a switch position. MODEL SW6 SW-6 7V V 4678 4678 SW - to : Function Switch mbient temp. -6 C or less SW9-,4 4 4 46 46 4

PUHZ-HRPYH PUHZ-HRPYH INDOOR UNIT [LEGEND] SYMBOL NME SYMBOL NME SYMBOL NME TB Terminal Block<Power Supply> P.B. Power Circuit Board C.B. Controller Circuit Board TB Terminal Block<Indoor/Outdoor > TB-U/V/W Connection Terminal<U/V/W-Phase> SW Switch<Manual Defrost, Defect History Record MC Motor for Compressor TB-L/L/L Connection Terminal<L/L/L-Power Supply> Reset, Refrigerant ddress> MF, MF Fan Motor TB-P Connection Terminal SW4 Switch<Test Operation> S4 Solenoid Valve (Four-Way Valve) TB-C Connection Terminal SW Switch<Function Switch, Model select> 6H Pressure Switch TB-N Connection Terminal SW6 Switch<Model Select> 6L Pressure Switch X C Relay SW7 Switch<Function Set up> 6HS Pressure Sensor N.F. Noise Filter Circuit Board SW8 Switch<Function Set up> TH Thermistor<Liquid> LI/LI/LI/NI Connection Terminal<L/L/L/N-Power Supply> SW9 Switch<Function Switch> TH4 Thermistor<Discharge> LO/LO/LO/NO Connection Terminal<L/L/L/N-Power Supply> SWP Switch<Pump Down> TH6 Thermistor<Outdoor -Phase Pipe> GD, GD Connection Terminal<Ground> CN Connector<Emergency Operation> TH7 Thermistor<mbient> CV.B. Converter Circuit Board SV Connector<Connection for Option> TH Thermistor<Suction> L-/IN Connection Terminal<L-Power Supply> SS Connector< Connection for Option> TH Thermistor<Ref. check> L-/OU Connection Terminal<L-Power Supply> LED, LED LED<Operation Inspection Indicators> LEV-, LEV-B, LEV-C Electronic Expansion Valve L-/OU Connection Terminal<L-Power Supply> CNM Connector<-Control Service Inspection Kit> CL~CL4 Reactor L-/OU Connection Terminal<L-Power Supply> CNDM Connector RS Rush Current Protect Resistor N-IN Connection Terminal < Connection for Option(Contact Input)> CB, CB Main Smoothing Capacitor CK-OU Connection Terminal F~F4 Fuse<T6.LV> CK Capacitor X,X,X4 Relay MF MS ~ MF MS ~ TB S S S C.B. CNS YLW ORN BRN 7 7 CNF CNF CNDC (PNK) 6HS 6H 6L TH TH TH7 TH6 TH TH4 F F t 4 TH TH TH7/6 TH TH4 6HS (YLW) () () 6L () 6H (YLW) CN4 TRNS t t CNC 4 t t t F F4 RS CN 7 P.B. 7 7 CN7 CN4 CN () X LED LEV- M LEV- LED 7 6 X S4 (GRN) CN + -- + -- TB-P + LEV-B () 6 X4 SV (GRY) TB-C + CNVMNT CNMNT TB-V TB-L TB-L TB-L TB-N + + CB CB CK X SS TB-W TB-U WHT WHT W MC V MS U ~ When M-NET adapter is connected L-OU B S TB7 L- L-OU CN LED LED LED4 SW SW SW CND CNM LED M-NET L- LED L-OU L- L- L-IN N-IN CK-OU S4 WHT CNM 4 6 LEV-C (BLU) LEV-C M LEV-B M SW SW8 SW4 SWP SW SW6 CN CNDM SW9 SW7 CN MODEL Y WHT WHT CN7 SW6 4678 4678 CV.B. MODEL SELECT The black square ( ) indicates a switch position. Y M-NET DPTER SW - to : Function Switch M-NET DPTER SYMBOL TB7 CN CND CNM SW SW SW LED LED LED LED4 LED SW-6 46 46 NME Terminal Block<M-NET connection> Connector<Transmission> Connector<Power Supply> Connector<M-NET communication> Switch<Status of communication> Switch<ddress setting : s digit> Switch<ddress setting : s digit> LED<Power Supply : DCV> LED<Connection to Outdoor Unit> LED<Transmission : Sending> LED<Transmission : Receiving> LED<Power Supply : DCV> N.F. POWER SUPPLY N~ V Hz TB L L L WHT LI LI U LI U U CNC CNCT () CNC () LO LO LO WHT BLU CL CL CL N BLU NI U NO BLU GRN/YLW U GD GD CNDC (PNK) + BRN WHT + U -- CNL (BLU) CL4 Setting of the starting ambient temp. of the flash injection. The black square ( ) indicates a switch position. mbient temp. C or less (lnitial setting) SW9-,4 4 4 4. SW9- to : Function Switch mbient temp. C or less SW9-,4 4 4 mbient temp. - C or less SW9-,4 4 4 mbient temp. -6 C or less SW9-,4 4 4

REFRIGERNT SYSTEM DIGRM -. INDOOR UNIT unit : mm PL-RP B/B/B PK-RP GL PK-RP FL() PED-RP J(L) PED-RP E() PED-RP G Heat exchanger Thermistor TH (Cond./Eva. temperature) Strainer(#) Refrigerant GS pipe connection (Flare) Refrigerant flow in cooling Refrigerant flow in heating Thermistor TH (Room temperature) Distributor with strainer(#) Thermistor TH Pipe temperature (Liquid) Strainer(#) Refrigerant LIQUID pipe connection (Flare) PK-RP HL PK-RP KL Heat exchanger Strainer (#) Refrigerant GS pipe connection (Flare) Thermistor TH Pipe temperature(liquid) Refrigerant flow in cooling Refrigerant flow in heating Thermistor TH (Cond./ Eva.temperature) Refrigerant LIQUID pipe connection (Flare) Thermistor TH (Room temperature) Distributor with strainer (#/#: HL) (#/#: KL) Strainer (#) 6

Unit : mm (inch) -. OUTDOOR UNIT PUHZ-HRP7VH PUHZ-HRPVH PUHZ-HRPYH PUHZ-HRPYH Refrigerant GS pipe connection (/8 inch) Ball valve Strainer # Charge plug ( pressure) Strainer # Linear expansion valve B Power receiver Solenoid valve (Four-way valve) Strainer # Charge plug ( pressure) pressure switch 6L Strainer # Muffler Compressor pressure switch 6H Thermistor TH (Outdoor pipe) Thermistor TH4 (Discharge) Heat exchanger Linear expansion valve Injection port Strainer # Thermistor TH7 (Outdoor) Thermistor TH6 (Outdoor -phase pipe) Thermistor TH (Outdoor pipe) Distributor Thermistor TH (Outdoor pipe) Bypass valve Replace filter Refrigerant LIQUID pipe connection Strainer (/8 inch) # Stop valve (with service port) Linear expansion valve C Heat interchange circuit Restrictor valve Strainer # Refrigerant flow in cooling Refrigerant flow in heating PUHZ-HRP7VH PUHZ-HRPVH PUHZ-HRPYH PUHZ-HRPYH Refrigerant GS pipe connection (/8 inch) Ball valve Strainer # Charge plug ( pressure) Solenoid valve (Four-way valve) Strainer # pressure sensor(6hs) Charge plug ( pressure) pressure switch 6L Muffler pressure switch 6H Thermistor TH (Outdoor pipe) Thermistor TH4 (Discharge) Heat exchanger Strainer # Thermistor TH7 (Outdoor) Thermistor TH6 (Outdoor -phase pipe) Thermistor TH (Outdoor pipe) Distributor Thermistor TH (Outdoor pipe) Strainer # Strainer # Linear expansion valve Linear expansion valve B Power receiver Compressor Injection port Refrigerant LIQUID pipe connection Strainer (/8 inch) # Stop valve (with service port) Linear expansion valve C Heat interchange circuit Refrigerant flow in cooling Refrigerant flow in heating 7

6 PERFORMNCE CURVES FOR THE COMBINTI OF OUTDOOR UNIT PUHZ-HRP VH(), PUHZ-HRP YH() Rated cooling capacity.4 Indoor intake air wet-bulb temperature <W.B. :> Cooling capacity ratio...8 8 6.6-46 Outdoor intake air dry-bulb temperature <D.B. > Rated cooling input. 8 6 Cooling input ratio..8.6 Indoor intake air wet-bulb temperature <W.B. :>.4-46 Outdoor intake air dry-bulb temperature <D.B. > Note : This diagrams show the case where the operation frequency of a compressor is fixed. 8

Rated heating capacity.4. Capacity ratio..8 Indoor intake air dry-bulb temperature <: D.B.>.6 - - - - - Outdoor ambient temp.( CWB) Rated heating input.. Input ratio.. Indoor intake air dry-bulb temperature <: D.B.>. - - - - - Outdoor ambient temep.(ºcwb) 9

7 CORRECTI FCTORS PUHZ-HRP7, VH() PUHZ-HRP, YH() Cooling capacity correction factors Refrigerant piping length (one way) Outdoor unit m m m m m m m m 7m 8m PUHZ-HRP7VH()..988.966.946.99.9.9.897.876.87 PUHZ-HRPVH() PUHZ-HRPYH()..98.97.9.98.886.876.86.846.89 PUHZ-HRPYH()..98.946.94.88.88.84.84.8.79 Heating capacity correction factors Refrigerant piping length (one way) Outdoor unit m m m m m m m m 7m 8m PUHZ-HRP7VH()..997.99.98.979.97.97.967.96.9 PUHZ-HRPVH() PUHZ-HRPYH()..997.99.98.979.97.97.967.96.9 PUHZ-HRPYH()..997.99.98.979.97.97.967.96.9

8 PPLICBLE EXTENSI PIPE FOR ECH MODEL 8-. PIPE LENGTH 8--. : SYSTEM Pipe length <Table > Maximum pipe length Liquid pipe (mm) Gas pipe (mm) OD Thickness OD Thickness HRP7~.7 t.8 9. t.8.88 t. Standard size m [m] 9. t. m [m].88 t. m [m] The maximum length is 7m in case of new pipes..7 t.8 9. t. m [m] <Marks in the table> m [m] : It can be used. : dditional refrigerant charge is required when the pipe length exceeds m. The maximum pipe length Charge-less pipe length 8--. TWIN SYSTEM () TWIN SYSTEM <Table > Maximum pipe length HRP7(RP ) HRP(RP ) Main pipe Liquid pipe 6. 9. 9. 9. (mm) [] Gas pipe.7.88.88 9. Liquid pipe 6. Standard size Standard size Gas pipe.7 m [m] m [m] m [m] Branch pipe Liquid pipe 9. m m m (mm) Gas pipe.88 [B, C] [m] [m] [m] Liquid pipe 9. Gas pipe 9. The maximum length is 7m in case of new pipes..7 9. m [m] m [m] 9..88 Standard size m [m] HRP(RP ) 9. 9. m [m].7 9. m [m] h Indoor unit B Indoor unit side C Indoor unit H Distribution pipe Outdoor unit Outdoor unit side <TWIN SYSTEM> Total length + B + C Max. 7 m Height difference H(Indoor unit-outdoor unit) h(indoor unit-indoor unit) Max. m Max. m Distance between indoor and indoor units Pipe length B-C Max. 8m Number of bends (one way) Max. (Max. 8 points between main pipe and each branch pipe(b, C)) 4

8-. DJUSTING THE MOUNT OF REFRIGERNT Check additional refrigerant charging amount referring to table, 6 when liquid pipe is one size larger than standard diameter. <Table > Required additional charge when the liquid pipe is one size larger than the standard diameter (: SYSTEM) Outdoor unit Liquid pipe O.D. Refrigerant amount to be added (Exceeding m) PUHZ-HRP7-.7 g per m <Table 6> Required additional charge when the liquid pipe is one size larger than the standard diameter (TWIN SYSTEM) Outdoor unit When the extension pipe length (main piping + branch piping) exceed m PUHZ-HRP7- dditional refrigerant amount W(g) = ( L) + ( L) + ( L) - If the calculation produces a negative number ( W ), additional charging is not necessary. L:.7 liquid pipe length (m) L: 9. liquid pipe length (m) L: 6. liquid pipe length (m) <Table 7> dditional refrigerant charging amount for pipe of standard diameter Type : system Outdoor unit PUHZ-HRP7- Permitted pipe length 7m or less mount of unit filling refrigerant (kg).kg m.6kg dditional refrigerant charging amount for pipe length exceeding m (kg) 4 m.kg m.8kg 6 7m 7 7m.4kg Type Twin system Outdoor unit PUHZ-HRP7- Permitted pipe length 7m or less mount of unit filling refrigerant (kg).kg m.6kg dditional refrigerant charging amount for pipe length exceeding m (kg) 4 m.kg m.8kg 6 7m 7 7m.4kg 4

8-. CPCITY CORRECTI CURVES Cooling and heating capacity is lowered according to pipe length. Capacity can be obtained by referring to the capacity curves below. When the diameter of gas pipe is one size smaller than standard diameter, cooling capacity is lowered comparing to the standard diameter. The lowered capacity can be obtained by referring to capacity curves for gas pipe which is one size smaller than standard size. Corrected pipe length (m) = actual pipe length (m) + number of bends. (m) [Sample calculation] Indoor unit RP o units (Twin system) Outdoor unit HRP o Condition Using existing pipes. Outdoor unit side Liquid pipe [.7 / Gas pipe [9. pipe length () m Indoor unit side Liquid pipe [9. / Gas pipe [.88 pipe length (B) m + (C) m ) Farthest piping length m + m = m Number of bends : ) Corrected piping length m +. o = 8m ) Capacity correction Outdoor unit side s gas pipe [9. Standard [.88 size up Refer to Capacity curves <Standard size> 4) Capacity Cooling capacity = Standard cooling capacity o.89 Heating capacity = Standard heating capacity o.98 Capacity curves for PUHZ-HRP H() model <Standard size> 9 Heating HRP7- Capacity ratio [%] 9 8 8 7 Note: The permitted pipe length is up to 8m. 7 4 6 7 7 8 Corrected pipe length [m] Cooling HRP7 model Cooling HRP model Cooling HRP model Cooling Heating When gas pipe is one size larger than standard size for PUHZ-HRP7-. Capacity can be obtained by referring to capacity curves of standard size. 4

9 IR FLOW DT 9-. OUTLET IR SPEED ND COVERGE RNGE PL-RP6B PL-RPB PL-RPB PL-RP7B PL-RPB PL-RPB PL-RPB PL-RPB PL-RPB ir fl ow m /min. 8 8 ir speed m/sec..6...7..4 Coverage range m 4. 4.8 4.8.6 8 8. PK-RPGL PK-RPGL ir fl ow m /min. ir speed m/sec... Coverage range m (ft) (.8) (.8) PK-RPFL PK-RPFL PK-RPFL ir fl ow m /min. 8 ir speed m/sec. 4.9.4 Coverage range m (ft).4(.7). (.) PK-RPHL PK-RPHL ir fl ow m /min. ir speed m/sec. 6. 6. Coverage range m (ft).8 (.4).8 (.4) PK-RPKL PK-RPKL ir fl ow m /min. 6 ir speed m/sec. 6. 6.8 Coverage range m (ft) 4. (46.9) 6. (.8) w The air coverage range is the distance to which the. m/sec air can reach, when air is blown out horizontally from the unit at the notch position. The coverage range should be used only as a general guideline since it varies according to the size of the room and the furniture inside the room. 44

9-. PL-RP B/B/B 9-- FRESH IR INTKE ND BRNCH DUCT. Branch duct hole and fresh air intake hole (Fig. ) t the time of installation, use the duct holes (cut out) located at the positions shown in Fig., as and when required. fresh air intake hole for the optional multi function casement can also be made. Note: The figure marked with * in the drawing represent the dimensions of the main unit excluding those of the optional multi function casement. When installing the optional multi function casement, add mm to the dimensions marked on the figure. When installing the branch ducts, be sure to insulate adequately. Otherwise condensation and dripping may occur. Fresh air intake hole Branch duct hole Fresh air intake hole diagram -.8 burring hole burring hole pitch Indoor unit *8 cut out hole Drain pipe Ceiling Refrigerant pipe Branch duct hole diagram (view from either side) 9 9 7 * *67 7 burring hole pitch 4-.8 burring hole cut out hole Fig. 4