Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Similar documents
Check valve, pilot operated

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Pressure relief valve, pilot operated

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Pressure reducing valve, pilot operated

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Throttle and throttle check valve

Meter-in pressure compensator, direct operated

Pressure reducing valve, direct operated, with pressure monitoring

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

Pressure relief valve, pilot operated

2-way flow control valve

Twin throttle check valve

Supply pressure compensator, direct operated

Check valve, pilot operated

2-way flow control valve

Pressure relief valve, pilot operated

Double throttle check valve Type Z2FS 10

Check valve, pilot operated

Pressure sequence valve, direct operated

Check valve, pilot operated

Check valve, pilot operated

Throttle and throttle check valve

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

3/2 and 4/2 directional poppet valve with solenoid actuation

Pressure reducing valve, direct operated

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Pressure sequence valve, direct operated

Pressure reducing valve, direct operated

Proportional pressure reducing valve, pilot operated

Pressure relief valve, pilot operated

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Throttle check valve. Type Z2FS. Size 16 Component series 3X Maximum operating pressure 350 bar [5076 psi] Maximum flow 250 l/min [66 US gpm]

Check valve cartridge Type M-SR

Proportional pressure relief valve, directly operated, rising characteristic curve

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Hydro-electric pressure switch

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Pressure reducing valve, direct operated

Pressure relief valve, directly operated

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

Bourdon tube pressure switch with infinitely variable switching pressure differential

Proportional flow control valve, 2-way version

Proportional pressure reducing valve, 3-way variant, pilot operated

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Throttle check valve. Type Z2FS. Features. Content. RE Edition: Replaces: 04.08

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Proportional pressure reducing valve, pilot operated

Pressure reducing valve, direct operated

Proportional flow control valve, with integrated pressure compensator

Throttle and throttle check valve

Directional spool and seat valves with electrical actuation and M12x1 plug-in connection

Filling valve sandwich plate

Bourdon tube pressure switch with infinitely variable switching pressure differential

Pipe burst safety valve

Check valve, pilot operated. Type SV and SL. Features. Contents. RE Edition: Replaces:

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition:

3/2 directional spool valve, direct operated with solenoid actuation

2/2-way poppet valves with solenoid operation Type KSDER1

2/2 directional seat valve, direct operated with solenoid actuation

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Pressure relief and feed valve, pilot operated. Type MHDBN. Features. Contents. RE Edition: Replaces:

2-way proportional throttle valve for block installation

Pressure reducing valve, pilot operated Type DR

Reservoir oil filler/breather

Check valve. Type Z1S. Contents. Features. RE Edition: Replaces: 09.10

3/2 and 4/2 directional seat valves with solenoid actuation

Proportional pressure relief valve, pilot operated

RC /

Proportional pressure reducing valve, pilot operated

Accumulator shut-off block. Type 0532VAW. Contents. Features. RE Edition: Replaces: 07.10

Pressure reducing valve, direct operated

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

4-way directional servo-valve

Directional servo-valve of 4-way design

Pressure relief valve, pilot-operated. Type DB and DBW. Features. Contents. RE Edition: Replaces:

Proportional pressure reducing valve, pilot operated

Rexroth Hydraulics. Pressure reducing valve, pilot operated, type 3DR 3DR 10 P 6X Y 00 RE /10.97

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

Pressure limitation and feed valve, pilot-operated Type MHDBN...Y

Hydraulic inch power brake valve LT 31

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

Steering unit. RE 14365/10.07 Replaces: Type LAGC. Sizes 50 to 630 Component series 1X and 2X Nominal pressure 175 bar Maximum flow 63 l/min

Accumulator shut-off block. Type ABZSS. Contents. RE Edition: Replaces: 05.13

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRTE. Features.

LUDV control block in mono block/sandwich plate design M7-20

Radial piston pump, fixed displacement

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

3/2 and 4/2 directional seat valves with solenoid actuation

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

Directional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents. RE Edition: Replaces: 04.

Winch control block. RE 65051/08.04 Replaces: Type YM-WCB

Proportional flow control valve. Type 2FRE. Features. Contents. RE Edition: Replaces: 02.07

Block mounting filter, for sandwich plate mounting

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Safety valves, directly operated

Transcription:

Check valve RE 2536/07.05 Replaces: 05.02 /6 ype ZS Size0 Component series 3X Maximum operating pressure 35 bar Maximum flow 00 l/min H5856 able of contents Contents Page Features Ordering code 2 Standard types 2 Symbols 3 Function, section 4 echnical data 4 Characteristic curves 5 Unit dimensions 5 Features Sandwich plate valve for use in vertical stacking assemblies Position of ports to ISO 440-05-04-0-94 8 different closing functions, optional Information on available spare parts: www.boschrexroth.com/spc

2/6 Bosch Rexroth AG Hydraulics ZS 0 RE 2536/07.05 Ordering code ZS 0 3X V * Check valve, sandwich plate Size 0 = 0 Leak-free closure in channel A (A A2) Leak-free closure in channel B (B B2) Leak-free closure in channel A (A2 A) Leak-free closure in channel B (B2 B) Leak-free closure in channels A and B (A2 A) and (B2 B) Leak-free closure in channels P and (P P2) and (2 ) Leak-free closure in channel P (P P2) Leak-free closure in channel (2 ) (for symbols, see page 3) Cracking pressure = A = B = C = D = E = F = P = 0.5 bar = 3.0 bar = 2 5.0 bar = 3 (Versions 2 and 3 not with soft seal "W4") V = No code = W4 = Further details in clear text Metal seal Soft seal Seal material FKM seals (other seals on enquiry) Caution! Observe compatibility of seals with hydraulic fluid used! 3X = Component series 30 to 39 (30 to 39: unchanged installation and connection dimensions) Standard types ype ZS 0 D-3X/V ZS 0 E-3X/V ZS 0 F-3X/V ZS 0 P-3X/V ZS 0-3X/V ZS 0 2-3X/V Material number R90047595 R90047596 R90047597 R90047590 R9004759 R900334980 Further standard types and components can be found in the EPS (standard price list).

RE 2536/07.05 ZS 0 Hydraulics Bosch Rexroth AG 3/6 Symbols ( = component side, 2 = plate side) ype ZS 0 A.-../.. ype ZS 0 D.-../.. P A 2 B P A 2 B ype ZS 0 P.-../.. ype ZS 0 B.-../.. P A 2 B P A 2 B ype ZS 0 E.-../.. ype ZS 0.-../.. P A 2 B P A 2 B ype ZS 0 C.-../.. ype ZS 0 F.-../.. P A 2 B P A 2 B

4/6 Bosch Rexroth AG Hydraulics ZS 0 RE 2536/07.05 Function, section Valves of type ZS are direct operated check valves of sandwich plate design. hey are used to check a flow leak-free in one direction and allow free flow in the opposite direction. he stroke of poppet (3) is limited by spring plate (4). An integrated spring (5) supports the closing movement. When no fluid flows through the valve, spring (5) holds poppet (3) in the closed position. ype ZS 0..-3X/V (with metal seal) his valve version is provided with a metal seal between poppet (3) and housing (). Valves of this version are particularly suitable for applications that involve operating pressures higher than 00 bar and flow velocities of more than 4 m/s. ype ZS 0..-3X/VW4 (with soft seal) his valve version is fitted with a soft seal between poppet (3) and housing () and provides hermetic sealing. Valves of this version are particularly suitable for applications with flow velocities of up to 4 m/s and low operating pressures. 4 A B 4 A B 5 5 3 3 A2 ype ZS 0 A-3X/V B2 A2 B2 ype ZS 0 A-3X/VW4 echnical data (for applications outside these parameters, please consult us!) General Weight kg approx. 2.3 Installation orientation Optional Ambient temperature range C 20 to +80 Hydraulic Maximum operating pressure bar 35 Cracking pressure Metal seal bar 0.5; 3; 5 Soft seal bar 0.5 Maximum flow l/min 00 Flow velocity Metal seal m/s > 4 Hydraulic fluid Soft seal m/s < 4 Hydraulic fluid temperature range C 20 to +80 Viscosity range mm 2 /s 2.8 to 500 Mineral oil (HL, HLP) to DIN 5524; fast bio-degradable hydraulic fluids to VDMA 24568 (see also RE 9022); HEG (rape seed oil); HEPG (polyglycols); HEES (synthetic esters); other hydraulic fluids on enquiry Max. permissible degree of contamination of the hydraulic fluid - cleanliness class to ISO 4406 (c) ) he cleanliness classes specified for components must be adhered to in hydraulic systems. Effective filtration prevents malfunction and, at the same time, prolongs the service life Class 20/8/5 ) of components. For the selection of filters, see data sheets RE 50070, RE 50076, RE 5008, RE 50086 and RE 50088.

RE 2536/07.05 ZS 0 Hydraulics Bosch Rexroth AG 5/6 Characteristic curves (measured with HLP46, ϑ oil = 40 C ± 5 C) Δp-q V characteristic curves (A to A2) Pressure differential in bar 8 6 4 2 With soft seal With metal seal Application limit for valve with soft seal 0 0 20 30 40 50 60 70 80 90 00 Flow in l/min Unit dimensions (nominal dimensions in mm) 6 Identical seal rings for ports A, B, P, and 2 his port is plugged in versions "F" and "". 50 3 With versions "F" and "", the check valve is installed in this channel. 4 3 Ø6,7 F 5 A A P B B F2 7 32,5 2 70 4 Nameplate 5 Position of ports to ISO 440-05-04-0-94; deviating from standard: Port (Ø Ø ) Ports X, Y as required: Caution! For drilled X and Y port (e.g. for pilot operated directional valve of size 0) version SO30 is valid! 6 Component side 7 Plate side F4 8,5 50,8 9 0,0/00mm F3 2 Valve fixing screws (separate order) 4 socket head cap screws ISO 4762 - M6-0.9 (friction coefficient µ total = 0.4); tightening torque M = 5.5 Nm ± 0% (please adapt in the case of changed surfaces) Rzmax 4 Required surface quality of mating part

6/6 Bosch Rexroth AG Hydraulics ZS 0 RE 2536/07.05 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 9786 Lohr am Main, Germany Phone +49 (0) 93 52 / 8-0 Fax +49 (0) 93 52 / 8-23 58 documentation@boschrexroth.de www.boschrexroth.de his document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. he data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. he information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.

RE 2536/07.05 ZS 0 Hydraulics Bosch Rexroth AG 7/6 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 9786 Lohr am Main, Germany Phone +49 (0) 93 52 / 8-0 Fax +49 (0) 93 52 / 8-23 58 documentation@boschrexroth.de www.boschrexroth.de his document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. he data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. he information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.

8/6 Bosch Rexroth AG Hydraulics ZS 0 RE 2536/07.05 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 9786 Lohr am Main, Germany Phone +49 (0) 93 52 / 8-0 Fax +49 (0) 93 52 / 8-23 58 documentation@boschrexroth.de www.boschrexroth.de his document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. he data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. he information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.