V200S. ±1% of flow rate; up to +/-0.5% if calibrated ANSI Class* 600# 150# 150# 600# 600# Drive Rods Single Double (150mm-1050mm)

Similar documents
Model Specifications V400S V400D Sensor Code Sensor Diameter 7/16 (11mm) 7/8 (22mm) 1-3/8 (35mm) 7/8 (22mm) 1-3/8 (35mm) Accuracy

Regular Models. V150 Spring Lock Threaded Components

V550 Spring Lock Flanged Connection with Packing Gland

VERIS FLOW MEASUREMENT GROUP

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

V200D VERIS Verabar (Double Rod) Installation and Maintenance Manual

VERIS FLOW MEASUREMENT GROUP

VERIS VERABAR VELOCITY AVERAGING FLOW SENSORS TRUE PERFORMANCE IN FLOW MEASUREMENT

V150 VERIS Verabar Installation and Maintenance Manual

V500 and V510 VERIS Verabar Installation and Maintenance Manual

Verabar Velocity Averaging Flow Sensors. True Performance in Flow Measurement

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

Averaging Pitot Tube Flowmeter Catalogue ED IN AUSTRALIA

Manifold and Isolation Valve Mounting System for Direct Mounting DP Transmitters

Rosemount 3051CFA Annubar Flowmeter

KB Series self averaging pitot flowmeter for gas, liquids and steam flows


Rosemount 285 Annubar Primary Element Series

Toroidal Conductivity Sensor

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes

Rosemount 485 Annubar Pak-Lok Assembly

Rosemount 1195 Integral Orifice Primary Element

Instrument Manifolds. V, VB, and VL Series. 2-, 3-, and 5-valve instrument manifolds

Mid-West Instrument FLOW MEASUREMENT PRODUCTS PRECISION FLOW TEST KITS VERABAR FLOW SENSORS

Rosemount TM 222 Toroidal Flow-Through Conductivity Sensor. Instruction Manual LIQ-MAN-222 Rev.D June 2017

Instrument Manifold Systems

PRESSURE GAUGES DIAL THERMOMETERS PRESSURE & TEMP. SWITCHES PRESSURE & TEMP. TRANSMITTERS PIPES, PIPE FITTINGS & FLANGES

ABB MEASUREMENT & ANALYTICS DATA SHEET. FPD350 Torbar Averaging pitot tubes

Static Pressure Manifolds M4AP and M4TP Manifolds

ANDERSON GREENWOOD LARGE BORE INTELLIMOUNT SYSTEM

Armstrong In-Line and Insertion Vortex Flow Meters

MANIFOLDS VALVE. Mfg & Exp. : Valves & Fittings. A Trusted Name in Valves and Fittings ISO 9001:2008 COMPANY. Catalogue No.

ANDERSON GREENWOOD M4AP/M4TP STATIC PRESSURE MANIFOLDS

Forged steel socket Welding fittings 6 ~ 13. Forged steel threaded fittings 14 ~ 20. Forged steel outlet fittings 21 ~ 23

Rosemount 3051T In-Line Pressure Transmitter

Vortex In Line Flow Meter

Engineered for control from tap to transmitter

Rosemount Manifolds. Rosemount Manifolds. Product Data Sheet , Rev NB January Contents

CONSTRUCTION MATERIAL 2 HOW TO ORDER 2 DESIGN FEATURES 3 PRODUCTS INDEX 4

OAKLEAF INVESTMENT HOLDINGS 52 (Pty) ltd

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011

ACCUTUBE Madison Avenue Cleveland, Ohio (216) FAX (216) web site:

Technical Manual MSI Hydraulic Adjustable Choke

Anderson Greenwood M4TL Liquid Level Manifolds

Forged Fittings. High Technology Valve & Fitting Series

FPD350 Torbar Averaging pitot tubes

F-2700 SERIES INSERTION VORTEX FLOW METER

ANDERSON GREENWOOD M25/M25A/M25B/M251/M251B MANIFOLDS

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

IFOA Integral Flow Orifice Assembly

Rosemount Manifolds. Product Data Sheet October , Rev PB. Factory assembled, leak-tested, and calibrated

Rosemount DP Flowmeters and Primary Elements

KDM ARMORED FLOW METER & SWITCH

F-2700 SERIES INSERTION VORTEX FLOW METER

VORTEX IN-LINE FLOW METERS

Table of Contents. Section 5: Installation Installation Procedure Pipe Preparation... S.l Accelabar Installation

Micro Motion Model D and DL Coriolis Flow and Density Meters

Signet 2517 Brass Paddlewheel Flow Sensor * *

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Rosemount 3051 Pressure Transmitter

PERFECTION IS OUR STANDARD...

Rosemount Manifolds. Product Data Sheet September , Rev PA. Factory assembled, leak-tested, and calibrated

ORIFICE PLATE flow meters

F-1500 SERIES INSERTION TURBINE FLOW METER

A type Ejectors (in line) Dimensions and weights

Static Pressure Manifolds M25, M25A, M25B, M251 and M251B

Large chamber type level gauge. Model : L110, L210. Description. Model LEVEL GAUGE GLASS. Model - L110. Model - L220

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY

Smith Meter PD Meter Meter, PD Series, K12- S1, S3, S5, S6, and S7

General Specifications

PROCHEM Stainless Steel Specialists

Kerotest KM4AP & KM4TP Static Pressure Manifolds

Temperature Sensor Series

RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response

mass flowmeter for compressed air

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

3. MECHANICAL SEALS GROUP 3.1 MECHANICAL SEALS 3.2 FLUSHING PLANS

Industrial Pt100 RTD's

Ball Valves. Seal Welded Style BVS2...2 Carbon Steel Technical Data 2200 PSI ¼ Stainless Steel Technical Data 2160 PSI ¼

RHM 12 - Standard 1 inch Coriolis Mass Flowmeter

Natural Gas Manifolds M6A, M6T, M6TA 5-Valve Manifolds

Anderson Greenwood M24A/M24T Differential Pressure Manifolds

RHM30. Coriolis Mass Flow Meter for Plant and Loading Flows. Features. Applications. Benefits

RHM 04. Universal Coriolis Mass Flowmeter with particular Fast Response. Applications. Features. Advantages

Rosemount 485 Annubar Threaded Flo-Tap Assembly

SECTION METERS AND GAGES FOR HVAC PIPING

ANDERSON GREENWOOD INSTRUMENTATION PRODUCTS INSTRUMENT VALVES PRODUCT OVERVIEW

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Powers Controls TT 184 Temperature Transmitters

Valves and manifolds

DIGI-TEL THERMOMETERS

For additional information, please visit our website at SENSOR SPECIFICATIONS

Process Industry. Diaphragm Seal Solutions

Rosemount DP Flowmeters and Primary Elements

Series W&T Pneumatic Control Valve Type RVG Globe valve and angle valve

SV SERIES THE ORIGINATOR OF PISTON-TYPE SAMPLING VALVES

TX115/215 Hot-tap Insertion Turbine Instructions

RHM 03. Flexible Coriolis Mass Flowmeter for low flow measurements. Applications. Features. Advantages

Anderson Greenwood PTM/PT7 Static Pressure Manifolds

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Transcription:

VERIS Verabar Hot Tap Models V200 Screw Drive Threaded Components The Most Accurate and Reliable Technology for Measuring Gas, Liquid and Steam Developed from aerospace technology, the VERIS Verabar averaging pitot flow sensor provides unsurpassed accuracy and reliability. With its solid, one-piece construction and bullet shape, the VERIS Verabar makes flow measurement leak resistant and precise. The unique sensor shape reduces drag and flow induced vibration. The location of the lowpressure ports significantly reduces the potential for clogging and improves signal stability. V200S V200D Pipe Connection Threaded (NPT) Mounting Type Ball or gate access valve Features and Benefits Applications Special Designs - Consult Factory V200 Hot Tap Most commonly used hot tap model Installation, insertion & retraction without system shutdown Economical single threaded rod for most applications Two threaded rods for high pressures Synchro drive simultaneously rotates both rods (double rod drives only) Patented, anti-seize orbital bearing aligns threaded rods and eliminates galling Can mount to existing valves Air (compressed, combustion) Natural gas Water (raw, cooling, feedwater) Steam Custom mounting, lengths, materials, instrument connections, etc. Short straight run Temperature Pressure Limits (ANSI Class)* 150# 275 psig @ 100 F (19 bar @ 38 C) 80 psig @ 800 F (5.5 bar @ 426 C) 600# 1440 psig @ 100 F (99.3 bar @ 38 C) 825 psig @ 800 F (56.9 bar @ 426 C) Model Specifications V200S V200D Sensor 05 10 15 10 15 Sensor Diameter 7/16 (11mm) 7/8 (22mm) 1-3/8 (35mm) 7/8 (22mm) 1-3/8 (35mm) Accuracy ±1% of flow rate; up to +/-0.5% if calibrated ANSI Class* 600# 150# 150# 600# 600# Drive Rods Single Double Pipe Size 2-6 (50mm-150mm) 6-42 (150mm-1050mm) 12-60 (300mm-1500mm) 6-42 (150mm-1050mm) 12-60 (300mm-1500mm) Instrument Connection 1/2 NPT or Direct Mount 1/2 NPT or Direct Mount Components Furnished Weld coupling, close nipple, access nipple and valve Weld Coupling Size 3/4 NPT 1-1/4 NPT 2 NPT 1-1/4 NPT 2 NPT * DIN and JIS flanges available. Consult factory.

VERIS Verabar Hot Tap Models 1. Enter Pipe Dimensions or Duct Dimensions H W ID Wall Dimension Verabar spans (H) or (W) Pipe Size Sch Pipe ID and Wall Pipe Material Height (H) Width (W) Wall Duct Material Synchro-Drive (Option SYN) Synchro-Drive Description Designed for pressures greater than ANSI Class 150#, Synchro-Drive is equipped with two drive rods that are coupled together by a protected chain drive system. Turning either drive nut simultaneously rotates both rods. Drive Chain 2. Pipe or Duct Orientation (Check one box) Protective Chain Shroud Anti-Seize Orbital Bearing (H) Horizontal (V) Vertical 3. Enter Flow Conditions Short Straight Run Consult Factory Drive Rod Synchro-Drive Benefits *U.S. Patent 5,410,920 95% faster and easier insertion and retraction. Equal load distribution over both rods maintains sensor alignment and eliminates binding. Fluid Name: Maximum Nominal Minimum Units Flow Rate All Fluids Gas Liquid Steam Pressure @ Flow Temperature @ Flow Specific Gravity, or Molecular Weight Specific Gravity VeraCalc Program can calculate Density from Temperature and Pressure 4. Select Model from Page 3 Use the Ordering Information table on Page 3 to determine your model number. 5. Flow Calculation All VERIS Verabar applications require a flow calculation to verify the DP, pressure and temperature limits, structural limits and to size the transmitter. VeraCalc is for use by representatives and end users. It is easy to operate and includes steam tables. 2

Cover Tube Sensor Bushing Instrument Head Sensor Plate Packing Bolts Threaded Bushing Packing Gland Jam Nut Access Nipple Threaded Drive Rod Access Valve Stop Nut Close Nipple Thread-o-let Sensor V200S (Single Rod) Cover Tube Sensor Bushing Instrument Head Sensor Plate Packing Bolts Threaded Bushing Packing Gland Jam Nut Access Nipple Threaded Drive Rod Access Valve Stop Nut Close Nipple Thread-o-let Sensor V200D (Double Rod) 3

Model Hot Tap Threaded Pipe Connections and Components V200S Single Rod, Insert/Retract, General Purpose (05 Class 600#, 10 and 15 Class 150#) V200D Double Rod, Insert/Retract, Higher Pressures (600# max.) (10 and 15 only) Pipe Size and Schedule or Exact ID and Wall Thickness Sensor Pipe Size Range 05 2 to 6 (50mm to 150mm) 10 6 to 42 (150mm to 1050mm) 15 12 to 60 (300mm to 1500mm) H V Pipe Orientation Horizontal Vertical Instrument Connections (Select Remote or Direct Mount) (Transmitter sold separately) Remote Mount Transmitter (1/2 NPT) Direct Mount Transmitter (Flanged 450 F/232 C Max.) Parallel Regular RTD* Valve Transmount Mass Transmount Manifold RTD P R D T F G M Instrument Valves (Opt.) Manifolds (Optional) Remote Mount Direct Mount Needle Gate 3-Valve 5-Valve 1/2 NPT 1/2 NPT Soft Seat Hard Seat Soft Seat C2NC(CS) C2NS(SS) C2GC(CS) C2GS(SS) F3SC(CS) F3SS(SS) F3HC(CS) F3HS(SS) F5SC(CS) F5SS(SS) Hard Seat F5HC(CS) F5HS(SS) Optional Sensor (Valve Size NPT) 05 (3/4 ) 10 (1-1/4 ) 15 (2 ) Mounting Assembly Select Valve Type & Material (Includes valve, close nipple & weld coupling) Type, Material & Rating B3B B5B B8B Ball, Brz., 600 psig @ 100 F, 100 psig @ 400 F (max.) B3C B5C B8C Ball, CS, 1000 psig @ 100 F, 100 psig @ 400 F (max.) B3S B5S B8S Ball, SS, 1000 psig @ 100 F, 100 psig @ 400 F (max.) G3C G3S G5C G5S G8C G8S Gate, CS, ANSI Class 600# Gate, SS, 1200 psig @ 100 F, 660 psig @ 800 F SYN WPS Options Synchronized Two Rod Drive System (Available for V200D-10 and V200D-15 sensors only) SS Wetted Components (Furnished with SS weld coupling, close & access nipple). Must be ordered with SS access valve. V200D 8 sch40 10 H R C2NC B5C SYN Typical Model Number * For high pressure (>500psig) or high temperature (>500 F), remote mount RTD in a thermowell is preferred. Assuming adequate heat dissipation for transmitter. 4

Instrument Head (SS) See options on ordering information page. VERIS Flow Measurement Group armstronginternational.com/veris VERIS Verabar V200 Single & Double Rod, Threaded DATE: 09/20/01 DWG. No. SUB-3936 Scale: NTS Rev: A Page 1 of 1 Armstrong VERIS Flow Measurement Group 6315 Monarch Park Pl, Niwot, CO 80503 - USA Phone: 303-652-8550 Fax: 303-652-8552 armstronginternational.com 1639-EN Printed in U.S.A. - 6/30/16 2016 Armstrong International, Inc.