Reliable Solution for Power Distribution. Air-Insulated Medium-Voltage Switchgear: Cost-Efficient, Sustainable and Safe

Similar documents
Cost-Efficient Solution for Power Distribution. Gas-Insulated Medium-Voltage Switchgear: Safe, Compact and Reliable

Totally Integrated Power. A reliable all-rounder. Gas-insulated medium-voltage switchgear 8DJH 36.

Distributing Power Economically. Totally Integrated Power. Gas-insulated medium-voltage switchgear: safe, compact, and reliable

Low- and Medium-Voltage Systems and Solutions

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy.

Gas-insulated medium-voltage switchgear. For marine and offshore applications. Answers for energy.

Gas-insulated medium-voltage switchgear. For the metal industry. Answers for energy.

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

NXPLUS C Single busbar. Maintenance-free for lifetime

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

High-current and generator switchgear from Siemens siemens.com/generatorswitchgear

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

The Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs

Vacuum Generator Circuit Breaker - A trend-setting power plant technology

8DJ. Maintenance-free for lifetime

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Benefits, typical uses

Reliable, economical and safe siemens.com/rail-electrification

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

XIRIA Green, Smart, Compact solution

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

The Smart Way. HVDC PLUS One Step Ahead. Answers for energy.

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Welcome to the world of electromobility!

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

Xiria the smart solution

Faster project implementation. Earlier return on invest. SIMOTICS HV M shaft height 450 to 800: the modular motor concept up to 19 MW

3AH37 and 3AH38 vacuum generator circuit-breakers for power stations and industry

Xiria the smart solution

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

Enabling the power of wind. Competence and expertise for wind power customers

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

SIGENTICS HV Series S-modyn

GRAND RENEWABLE ENERGY PARK PROJECT DESCRIPTION REPORT. Attachment C. Turbine Specifications

B kv Gas-insulated Substations

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

The SGT5-8000H proven in commercial operation

Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner

OVER 1,000,000 VERSIONS, BUT ONLY ONE ORIGINAL FLENDER GEAR UNITS

ABB Low voltage systems MNS Platform

Xiria 24 kv Ring Main Unit

ABB Next Level Big shift in power attractive opportunities


3AP1 DTC for 145 and 245 kv

Independent Testing Laboratory for High Voltage Equipment

ABB life cycle services Uninterruptible power supplies

This small footprint makes a BIG impact

Powering business worldwide

Power Transmission and Distribution. NXPLUS C double busbar. The economical solution when replacing old systems

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

the safe, reliable, and efficient choice for MV switchgear

Xiria 12 kv Ring Main Unit in IEC and ENATS design

CGMCOSMOS Fully gas-insulated modular and compact (RMU) system Up to 24 kv

SION vacuum circuit-breaker.

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.

Metal Clad Switchgears

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

The Modular System. Modular System

Exceeding the standards with MNS

The specialist in Medium Voltage

Siemens G2 platform 2.3-MW geared wind turbines. Exceptional performance, proven reliability. Answers for energy.

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

SMA Utility Power System

The comprehensive portfolio of the testing laboratories at Schaltwerk Berlin siemens.com/energy/psw

Medium voltage vacuum circuit breaker. E-VAC series

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

Magnefix kv Insulation enclosed switchgear. Magnefix. Compact switchgear for medium voltage distribution

SIMOBREAKER The New Substation with Rotary Disconnector Fully Assembled, Compact and with High Availability

cgm.3 2 ry Distribution Switchgear

Ahead of the challenge, ahead of the change. A comprehensive power transmission & distribution with Totally Integrated Power

Low Voltage Main Distribution Board

Power and Distribution Transformers

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Valid for you. medium voltage switchgear

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Wind is our Element. siemens.com/loher-windgenerators. Answers for industry.

Bright outlook for improved profitability. Direct drive wind turbine SWT Answers for energy.

B kv T&D GAS INSULATED SWITCHGEAR

Siemens G2 platform 2.3-MW geared wind turbines. Exceptional performance, proven reliability. Answers for energy.

ABB Medium Voltage Days MEA 2016 Medium-voltage gas insulated switchgear Technologies for a smarter and greener network

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

UniGear. Technical Guide

MNS PDUpro Intelligent power distribution unit

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Modular medium-voltage switchgear. NorMax

ZX-Family Gas-insulated medium voltage switchgear

New dimensions. Siemens Wind Turbine SWT Answers for energy.

Low Voltage Systems MNS platform

INESING SWITCHGEAR BROCHURE

W-VACi MV circuit breakers

CPG.0 Single busbar gas-insulated cubicles

Eaton Safe, Reliable, Efficient IEC MV Switchgear. xgear Safe, Reliable, Efficient IEC MV Switchgear

3EK7 Distribution Class Surge Arresters. Answers for energy.

Transcription:

www.siemens.com/mediumvoltage Reliable Solution for Power Distribution Air-Insulated Medium-Voltage Switchgear: Cost-Efficient, Sustainable and Safe Answers for infrastructure and cities.

Contents Air-insulated medium-voltage switchgear from Siemens 3 The powerful centerpiece of your medium-voltage grid 4 A class of itself 6 Portfolio overview 10 Selection matrix 11 NXAIR, NXAIR P 12 NXAIR S 13 8BT1, 8BT2 14 8BK80, 8BK88 PLUS 15 GM-SG, GM-SG-AR, GM38 16 SIMOVAC-NAR, SIMOVAC-AR 17 2

Air-insulated medium-voltage switchgear from Siemens The clever solution... Medium-voltage grids are facing great challenges worldwide: On the one hand, energy demand is increasing due to continuous growth of population, progressive urbanization and industrialization, as well as new tasks such as electromobility. On the other hand, more and more power from renewable sources must be supplied to the grids via the medium-voltage level in order to reach the ambitious climate targets. That is why modern medium-voltage switchgear must not only be environmentally compatible, sustainable and safe, but also costefficient, reliable and intelligent, e.g. by allowing integration into higher-level control and protection systems. With Siemens, you have a competent partner by your side for all these questions. Air-insulated medium-voltage switchgear from Siemens is the clever solution for the challenges of today and tomorrow. Your benefits at a glance Comprehensive supply of air-insulated switchgear for primary distribution grids High cost-efficiency by modular design and use of maintenance-free circuit-breakers High switchgear availability and personal safety Contribution to sustainability by environmentally neutral insulating medium High security of investment by optional integration in smart distribution grids High product quality from Siemens, one of the pioneers of air-insulated switchgear Reliable and competent support on site from planning to operation 3

The powerful centerpiece of your medium-voltage grid Flexibility, reliability, maximum personal safety, and low costs for operation and maintenance: Air-insulated medium-voltage switchgear from Siemens is the ideal system for the primary distribution level in industry and infrastructure, or for utilities. As a globally leading technology company, we are also fostering the development of air-insulated switchgear today, offering all switchgear with type tests according to IEC 62271-200 or ANSI/IEEE C37.20.2. Environmentally compatible, sustainable and especially safe, this switchgear can be easily integrated in higher-level control and protection or energy management systems, or in Smart Grids. Security for utilities Our air-insulated medium-voltage switchgear combines high personal and operational safety with excellent cost efficiency: Maintenance-free vacuum circuit-breakers and easily replaceable withdrawable parts reduce downtimes and increase availability. In addition, with our strategically distributed production centers we are close to you worldwide, and we can also integrate local know-how into our switchgear according to the different requirements from country to country. Cost efficiency for the chemical industry Uninterrupted power supply, also under aggressive atmosphere, is indispensable for the chemical industry to guarantee stable processes. This is a task for our reliable air-insulated medium-voltage switchgear. The advantage: Secure supply of large consumers and low-voltage switchboards ensures long-term system availability and security of investment throughout the entire life cycle. High availability for the automobile industry Globally operating automobile manufacturers need highly flexible, profitable and maximally available production lines, as every minute of standstill of the belt causes high costs. Therefore, a reliable power distribution is crucial for success. For our air-insulated medium-voltage switchgear, maintenance-free vacuum circuit-breakers and maintenance intervals of more than ten years provide optimum availability values. 4

In addition, modular design and standardized elements allow for the quick replacement of individual components as well as easy extension, for example during the modernization of your production. Secure supply in the data center Data centers belong to the largest energy consumers worldwide. For this purpose, maximum availability is required and therefore reliable power supply around the clock. Faults or breakdowns for sure mean interruptions of operation and data loss as well as unforeseeable financial consequences. Our well-proven air-insulated medium-voltage switchgear provides a secure and reliable supply of your data center, allowing integration in modern infrastructure thanks to its compact design. Hardest conditions in the oil and gas industry The global demand for oil and gas continues increasing, but new deposits are found more and more in rough, harsh regions of the Arctic Zone or in deep sea. Offshore platforms require vibration- and shock-tested switchgear with a high degree of protection. Therefore, the requirements on power supply are even higher. Thanks to the maintenance-free circuit-breaker and the modular, solid design, air-insulated medium-voltage switchgear from Siemens is an important component for smooth and cost-efficient operation without expensive downtimes. Cost-efficient production processes in mining applications or in the metal industry Also in mining applications and in the metal industry, safe and reliable, highly available power supply is indispensable: High currents, e.g. for the supply of electric arc furnaces, and a large number of operating cycles are typical. Our especially safe air-insulated medium-voltage switchgear meets these requirements with its maintenance-free circuit-breakers, also used as increased-frequency circuit-breakers with a large number of operating cycles, and the maintenance-friendly withdrawable design as well as a high short-time withstand current. Reliable in the paper and pulp industry Increasing cost pressure in aggressive competition, highest demands on quality and availability power supply in the paper industry must reliably accomplish complex tasks. Air-insulated switchgear from Siemens supports you in this, delivering electricity in the range of a hundred megawatt hours safely, reliably and cost-efficiently to the different consumers at peak load. In other branches such as the food and beverage industry, air-insulated switchgear from Siemens puts energy under your control. Allow yourself to be convinced of the benefits of air-insulated medium-voltage switchgear. 5

A class of itself At a time of growing cost and performance pressure it is even more important to decide on the right technology, above all because switchgear represents an investment for the next decades. Therefore, the profile of our air-insulated medium-voltage switchgear is clear: A maximum degree of safety, reliability and availability. In this way, our well-proven technology enables cost-efficient and reliable operation, and also fully exploits its strengths regarding sustainability, because air-insulated switchgear is environmentally neutral. 6

Security of operation Air-insulated switchgear from Siemens is type-tested and fulfills the standard IEC 62271-200. Most modern production processes and quality standards provide for reliable operation of the switchgear. For us, optimum security of operation starts with functions such as the verification of the making and breaking capacity of the circuit-breaker and earthing switch integrated in the panel, and even with the verification of the confinement of an internal arc to the respective compartment, depending on the switchgear type. Measures taken to meet the requirements regarding the optimum degree of protection, as well as a modular design and the use of standardized components allow for uninterrupted operation and a sustainable increase of productivity. Personal safety Every air-insulated switchgear from Siemens for the IEC market is approved with internal arc classification IAC A FLR, and with loss of service continuity category LSC 2B, LSC 2A or LSC1 depending on the switchgear type, as well as with partition class PM. This makes the equipment suitable for universal installation, satisfying the highest requirements regarding personal safety. In this way, air-insulated switchgear from Siemens offers a well-proven, safe design with vacuum circuit-breakers and racking of the circuit-breaker truck with closed high-voltage door, as well as a degree of protection of up to IP51, metal enclosure and earthed shutters and partitions. Cost-efficient A service life of more than 30 years not only optimizes the energy balance, but also makes our air-insulated switchgear a cost-efficient investment. The compact design of our air-insulated medium-voltage switchgear and the use of the vacuum circuit-breakers pays off twice for you. On the one hand, building costs are reduced due to minimum space requirements, and on the other hand, the maintenance-free design of the circuit-breaker enables largely continuous operation without expensive downtimes. In addition, the modular and withdrawable design of our switchgear accelerates repairs, e.g. by means of withdrawable vacuum circuit-breakers or vacuum contactors. Well-accessible cable connections reduce the assembly times and save installation costs. Cable testing can be done easily and quickly. The safety concept is completed with a comprehensive logical mechanical interlocking system which protects against maloperation. All switching operations are possible only with closed high-voltage door, on which unambiguous position indicators and control elements support safe operation. 7

Intelligent Today, medium-voltage switchgear must not just offer safe and reliable power distribution. In times of energy efficiency and Smart Grids, it also has the task to acquire and transmit measured values and data about actual states from the panel level, in order to enable their evaluation in a higher-level control center. For this purpose, our switchgear can be equipped with built-in telecontrol units; integration in control and protection systems and Smart Grids can be implemented via several protocols (such as IEC 61850, PROFIBUS, MODBUS, DNP). Depending on the level of the Smart Grid functionality, more benefits result, such as high availability, fast localization of faults, early detection of overload situations, safe operational management. Moreover, load characteristics can be recorded and used for optimal planning of grid expansions. Sustainable The great advantage of air-insulated medium-voltage switchgear: The insulating medium air is available always and everywhere, without further technical efforts, such as for example gas pressure monitoring. Reliable Development and production of our air-insulated medium-voltage switchgear is done worldwide based on the same high quality and environmental standards. Thereby, our customers benefit from the most modern tools in development and production, which allow for maximum quality and reliability of the systems. An example for this is the consequent use of 3D-CAD software, which transfers your data directly from the purchase order through the design department to the production, in order to become a switchgear ready for operation within a short time. Of course, the high quality of our air-insulated switchgear is ensured in our highly-modern, accredited testing and experimental laboratories. Besides type and routine tests of the individual type series, a quality assurance system according to DIN EN ISO 9001 and 14001 accompanies the process. Our testing laboratories range among the largest in the world, and have the status of independent testing institutes because of their affiliation to PEHLA and DAR. This switchgear concept has been well-proven for decades, and represents the most environmentally compatible solution for medium-voltage switchgear: If there is no need to use special insulation gases, those cannot escape either; not to mention the contribution to the greenhouse effect. 8

Local creation of value country-specific flexibility Our air-insulated medium-voltage switchgear type series is developed and manufactured by international teams in the different regions of the world, with a regular exchange of information. In this way we do not only safeguard the local know-how for the different requirements from country to country, but also the transfer of experiences from other locations. All production processes are documented in a comprehensible way in order to reach the quality level our customers can expect in a fast, secure and reproducible way. Reliable support on site Our experts support you worldwide, and advise you, as our customer, to develop optimum solutions for your power distribution grid. In this context you will benefit, for example, not only from our know-how in project management and our financial services, but also from our experienced customer account managers, who consider all relevant aspects to the topics safety, logistics and environmental protection in their quotation. Especially in the planning phase, our experts from Totally Integrated Power (TIP) will accompany you with professional consulting, software tools, specification texts and planning manuals. 9

Portfolio overview Your region, your requirements and the matching solution from Siemens. At the same time, our matrix is your guide to the right air-insulated mediumvoltage switchgear from Siemens. In accordance with the relevant IEC, GB/DL or ANSI standards you will find the suitable offer to your requirements at one glance by selecting the appropriate combination of busbar system, as well as the basic electrical parameters. Transmission level, generation level, high-voltage grid Medium-voltage grid Primary distribution level Secondary distribution level Low-voltage grid 10

Selection matrix Electrical data (max.) Page Standard Distribution level Busbar system Switchgear type U r [kv] I k [ka] I busbar [A] I feeder [A] 7.2 12 15 17.5 24 27.5 36 40.5 20 25 31.5 40 44 50 63 IEC Primary distribution level Single 8BT2 3150 3150 14 8BT1 2000 2000 14 NXAIR 2500 2500 12 4000 4000 12 NXAIR P 4000 4000 12 8BK80 3150 2500 15 4000 3150 15 8BK88 PLUS 1) 2000 1450 15 Primary distribution level Double NXAIR 2500 2500 12 GB/DL Primary distribution level Single NXAIR S 3150 3150 13 4000 4000 13 Selection matrix Electrical data (max.) Page Standard Distribution level Busbar system Switchgear type U r [kv] I k [ka] I busbar [A] I feeder [A] 7.2 13.8 15.0 27.6 38 40.5 20 25 31.5 40 44 50 63 ANSI Primary distribution level Single GM38 3000 3000 16 GM-SG-AR 4000 4000 16 GM-SG 4000 4000 16 SIMOVAC-AR 4000 720 17 SIMOVAC-NAR 4000 720 17 1) Short-time withstand current up to 26.3 ka 11

NXAIR, NXAIR P High-end technology in best form Technical features NXAIR NXAIR NXAIR P Rated values up to 17.5 kv, 40 ka, 3 s 24 kv, 25 ka, 3 s 17.5 kv, 50 ka, 3 s Busbar current up to 4000 A 2500 A 4000 A Feeder current up to 4000 A 2500 A 4000 A Busbars Single busbar Single and double busbar Single busbar Insulation Type of switchgear Air-insulated Factory-assembled, type-tested, metal-enclosed switchgear according to IEC 62271-200 Modular and extendable as individual panels Classification according to IEC 62271-200 Partition class PM Loss of service continuity LSC 2B category Accessibility to compartments Busbar compartment: Tool-based Switching-device compartment: Cable compartment: Interlock-controlled Interlock-controlled or tool-based Internal arc classification IAC A FLR 40 ka, 1 s IAC A FLR 25 ka, 1 s IAC A FLR 50 ka, 1 s Dimensions Panel width 435 mm, 600 mm, 800 mm, 1000 mm 800 mm, 1000 mm 400 mm, 800 mm, 1000 mm Panel height 2300 mm 2560 mm 2550 mm Panel depth For further information, see catalog HA 25.71 1350 mm, 1400 mm, 1500 mm, 1540 mm 1600 mm 1635 mm, 1650 mm Product range (in excerpts) Circuit-breaker panel Circuit-breaker panel Circuit-breaker panel NXAIR 17.5 kv NXAIR 24 kv NXAIR P 12 1) PI for switch-disconnector panel

NXAIR S High-end technology in best form for the Chinese market Technical features NXAIR S NXAIR S Rated values up to 12 kv, 40 ka, 4 s 24 kv, 31.5 ka, 4 s Busbar current up to 4000 A 3150 A Feeder current up to 4000 A 3150 A Busbars Insulation Single busbar Air-insulated Type of switchgear According to GB 3906-2006, DL 404 Modular and extendable as individual panels Classification according to GB 3906-2006, DL 404 Partition class PM Loss of service continuity LSC 2B category Accessibility to compartments Busbar compartment: Tool-based Switching-device compartment: Interlock-controlled Cable compartment: Interlock-controlled or toolbased Internal arc classification IAC A FLR 40 ka, 1 s IAC A FLR 31.5 ka, 1 s NXAIR S 12 kv Dimensions Panel width 650 mm, 800 mm, 1000 mm 1000 mm Panel height 2200 mm 2620 mm Panel depth 1350 mm, 1500 mm 1810 mm For further information, see catalog 1719-D909007-0213X for NXAIR S 12 kv, 1735-D909014-06131 for NXAIR S 24 kv NXAIR S 24 kv Product range (in excerpts) Circuit-breaker panel NXAIR S 12 kv Circuit-breaker panel NXAIR S 24 kv 13

8BT1, 8BT2 Compact design and simple construction Technical features 8BT1 8BT2 Rated values up to 24 kv, 25 ka, 3 s 36 kv, 31.5 ka, 3 s Busbar current up to 2000 A 3150 A Feeder current up to 2000 A 3150 A Busbars Insulation Type of switchgear Single busbar Air-insulated Factory-assembled, type-tested, metal-enclosed switchgear according to IEC 62271-200 Modular and extendable as individual panels Classification according to IEC 62271-200 Partition class PM / PI 1) PM Loss of service continuity category LSC 2A LSC 2B Accessibility to compartments Busbar compartment: Tool-based 8BT1 Switching-device compartment: Interlock-controlled Cable compartment from the front: Interlock-controlled Internal arc classification IAC A FLR 25 ka, 1 s IAC A FLR 31.5 ka, 1 s Dimensions Panel width 600 mm, 800 mm, 1000 mm 1200 mm Panel height 2300 mm 2750 mm (25 ka), 2800 mm (31.5 ka) Panel depth 1410 mm 2450 mm (FL), 2700 mm (FLR) For further information, see catalog 8BT1, HA 26.31, and catalog 8BT2, HA 26.41 8BT2 Product range (in excerpts) Circuit-breaker panel Switch-disconnector panel Circuit-breaker panel 8BT1 8BT2 14 1) PI for switch-disconnector panel

8BK80, 8BK88 PLUS Designed for local applications Technical features 8BK80 8BK80 8BK88 PLUS Rated values up to 12 kv, 44 ka, 3 s 36 kv, 31.5 ka, 3 s 12 kv, 26.3 ka, 3 s Busbar current up to 4000 A 3150 A 2000 A Feeder current up to 3150 A 2500 A 1450 A Busbars Single busbar Insulation Air-insulated Type of switchgear Factory-assembled, type-tested, metal-enclosed switchgear according to IEC 62271-200 Modular and extendable as individual panels Classification according to IEC 62271-200 Partition class PM Loss of service continuity category LSC 2B Accessibility to compartments Busbar compartment: Tool-based Switching-device compartment: Interlock-controlled 8BK80 Cable compartment: Tool-based IAC A FLR 40 ka, 1 s IAC A FLR 31.5 ka, 0.1 s IAC A FLR 26.3 ka, 1 s Panel width 700 mm, 800 mm, 1000 mm 1000 mm 600 mm Panel height (each without low-voltage compartment) 1500 mm 1700 mm 1250 mm Panel depth 1750 mm 2620 mm 1350 mm Internal arc classification Dimensions For further information see catalog 8BK80 12kV, ICSG-20-001-001; catalog 8BK80 36kV, ICSG-20-001-002; catalog 8BK88 PLUS, ICSG-20-001-003 8BK88 PLUS Product range (in excerpts) Circuit-breaker panel Circuit-breaker panel Circuit-breaker panel 8BK80 12 kv 8BK80 36 kv 8BK88 PLUS 15

GM-SG, GM-SG-AR, GM38 Flexibility is their strength Technical features GM-SG GM-SG-AR GM38 Rated values up to 15 kv, 63 ka, 3 s 15 kv, 50 ka, 3 s 38 kv, 31.5 ka, 2 s Busbar current up to 4000 A 4000 A 3000 A Feeder current up to 4000 A 4000 A 3000 A Busbars Insulation Type of switchgear Single busbar Air-insulated Factory-assembled, type-tested, metal-enclosed switchgear according to ANSI/IEEE C 37.20.7 Modular and extendable as individual panels Classification according to ANSI / IEEE C 37.20.7 Internal arc classification Not resistant to internal arcing Resistant to internal arcing Not resistant to internal arcing Dimensions Panel width 914 mm (36.0 ) 1016 mm (40.0 ) 1219 mm (48.0 ) Panel height 2419 mm (95.3 ) 2957 mm (116.4 ) 2794 mm (110.0 ) Panel depth 2507 mm (98.7 ) 2502 mm (98.5 ) 3302 mm (130.0 ) For further information, see catalog GM38, IC0001-F320-A131-X-4A00 and catalog GM-SG-/GM-SG-AR, IC1000-F320-A101-X-4A00 GM-SG GM-SG-AR Product range (in excerpts) Circuit-breaker panel GM-SG Switch-disconnector panel GM38 GM38 16

SIMOVAC-NAR, SIMOVAC-AR Medium-voltage motor control center Technical features SIMOVAC-NAR SIMOVAC-AR Rated values up to 7.2 kv, 63 ka, 2 s 7.2 kv, 63 ka, 2 s Busbar current up to 4000 A 4000 A Feeder current up to 720 A 720 A Busbars Insulation Type of switchgear Factory-assembled, type-tested, metal-enclosed switchgear according to ANSI/IEEE C 37.20.7 Modular and extendable as individual panels Klassifizierung gemäß ANSI / IEEE C 37.20.7 Internal arc classification Not resistant to internal arc Typ 2B Dimensions Panel width 915 mm (36 ) 914 mm (36 ) Panel height 2286 mm (90.0 ) 2845 mm (112 ) Panel depth 762 mm (30.0 ) 1029 mm ( 40.5 ) For further information, see catalog SIMOVAC, IC1000-F320-A144-V2-4A00 SIMOVAC-AR Product range (in excerpts) Disconnector panel SIMOVAC 17

Published by and copyright 2013: Siemens AG Wittelsbacherplatz 2 80333 Munich Germany Siemens AG Infrastructure & Cities Sector Low and Medium Voltage Division Medium Voltage & Systems Mozartstr. 31 C 91052 Erlangen Germany www.siemens.com/mediumvoltage For more information, please contact our Customer Support Center. Tel.: +49 180 524 8437 Fax: +49 180 524 2471 Charges depending on provider) E-mail: support.ic@siemens.com Low and Medium Voltage Division Order No. IC1000-G320-A174-V1-7600 Printed in Germany TH 260-130599 WS 0813 WÜ 3.0 Printed on elementary chlorine-free bleached paper. All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases.the required technical options should therefore be specified in the contract. www.siemens.com/mediumvoltage