SMP3CTX Series Power Supply/Charger

Similar documents
AL600ULX Series. Power Supply/Charger Installation Guide

DC CCTV Power Supplies Installation Guide

- 4 amp (100VA). - 4 amp (100VA). - Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.

Rack Mount Power Supplies

4 amp (100VA). - 4 amp (100VA). - Four (4) Fuse Protected - Four (4) PTC Protected

CCTV Rack Mount Power Supplies

CCTV Rack Mount Power Supplies

- 4 amp (100VA). - 4 amp (100VA). - Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.

UL Listed CCTV Power Supplies. - 4 amp. - 4 amp. - Eight (8) Fuse Protected - Eight (8) PTC Protected

- 4 amp. - 4 amp. - Sixteen (16) Fuse Protected - Sixteen (16) PTC Protected

- 8 amp (200VA) - 8 amp (200VA) - Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

Installation Instructions

AccuPower AQU128B Installation Instructions

AccuPower AQU126B Installation Instructions

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Product Installation Document

Installation Instructions

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Installation Instructions & Users Manual

DSP led gaming monitor USER MANUAL

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

DIESEL Engine Fire Pump Controllers Features

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

INSTALLATION MANUAL. Recessed In-Ceiling Motorized Projection Screen

Operating and Installation Instruction Manual

IEDA524-H / IEDA520DTB DIGITAL MICROPHONE STATION. Installation Instructions

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

At-FST Series I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S W W W. A I G I S M E C H. C O M

CHARGING UNIT DEM 313

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

Installation and Operations Manual

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG

4-Hour. Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

SAFETY WARNINGS AND GUIDELINES

Innovative Circuit Technology Ltd.

Plena 24 VDC Battery Charger. Installation and User Instructions PLN-24CH10

REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S MANUAL.

SCC-MPPT Solar Charge Controller

Solar Charge Controller

Mini Hi-Fi System *MFL * SIMPLE MANUAL

SCC-MPPT Solar Charge Controller

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Twelve Unit Rapid Charger

General Precautions. Personnel Precautions

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

Multi-Mover Charger for model L25

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

FC-27W 7 dome housing. Installation Instructions

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

SCC-MPPT Solar Charge Controller

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

PSDCB161220E. v.1.0. PSDCB 13,8V/20A/16x1A/65Ah. Buffer power supply for up to 16 HD cameras. EN** Edition: 3 from

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

BMRX Series Rotary Level Indicator

MicroPod Sub User manual / Bedienungsanleitung / Manual del Usario

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

POWERLINE 2000 Energy Management System TM

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

User Manual 1KVA-5KVA INVERTER / CHARGER

Steca Solarix PLI. Inverter / Charger with Solar Charge Controller. Installation and operating instructions. Download manual at

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

Uninterruptible Power System

Solar Hybrid Inverter SP Efecto Series

GENERALITIES TECHNICAL FEATURES

AUTO CHARGE LPC SERIES

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

MIL-24/2600Q MIL-24/3200DQ

Elmdene International Ltd

02OWNER S MANUAL 06 TROUBLESHOOTING 08LIMITED WARRANTY

EMIU 720W Mini Inverter

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

User Manual 1KVA-5KVA INVERTER / CHARGER

Owner s Manual. OutCast 1.2. The Ultimate Outdoor Speaker System

Solar Hybrid Inverter SP Brilliant Series

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

Innovative Circuit Technology Ltd.

KILOVOLT POWER SUPPLY

Fiber Optic Illuminator. Model 21AC Model 21DC

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

MASTERsine Inverter PXA Series Installation Guide

Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology.

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Foreword

Transcription:

SMP3CTX Series Power Supply/Charger Installation Guide Models Include: SMP3CTX SMP3PMCTX SMP3PMCTXX - Single Output. SMP3PMP4 - Four (4) Fuse Protected Outputs. SMP3PMP8 - Eight (8) Fuse Protected Outputs. SMP3PMP16 - Sixteen (16) Fuse Protected Outputs. SMP3PMP4CB - Four (4) PTC Protected Outputs. SMP3PMP8CB - Eight (8) PTC Protected Outputs. SMP3PMP16CB - Sixteen (16) PTC Protected Outputs. Rev. 121812 More than just power. TM

Overview: Altronix SMP3CTX Series power supply/chargers convert a 115VAC or 230VAC, 50/60Hz input into a regulated 12VDC or 24VDC output up to 2.5A of continuous load current (see specifications). SMP3CTX Series Power Supply Configuration Reference Chart: Altronix Model Number SMP3CTX SMP3PMCTX SMP3PMCTXX SMP3PMP4 Accessory Power Distribution Module(s) Number of Outputs Fused Outputs PTC Outputs (auto-resettable) Individual Output Rating (A) 1 2.5A PD4 P 2.5A 4 SMP3PMP4CB PD4CB P 2.5A SMP3PMP8 PD8 P 2.5A 8 SMP3PMP8CB PD8CB P 2.5A SMP3PMP16 PD16W P 2.5A 16 SMP3PMP16CB PD16WCB P 2.5A Supervised P 115VAC/ 230VAC Input Current (A) 12VDC/ 24VDC Total Output Current (A) 0.65A/0.35A 2.5A Agency Listings: CE European Conformity. Input: Input 115VAC, 50/60Hz, 0.65A or 230VAC, 50/60Hz, 0.35A. Output: 12VDC or 24VDC selectable output. 2.5A supply current. Filtered and electronically regulated outputs. Short circuit and thermal overload protection. Battery Backup: Built-in charger for sealed lead acid or gel type batteries. Maximum charge current 0.5A. Zero voltage drop when switching over to battery backup. Features: Power ON/OFF switch. Specifications: Supervision (select models): AC fail supervision (form C contacts). Low battery supervision (form C contacts). Visual Indicators: AC input and DC output LED indicators. Electrical: Operating temperature: 0º C to 49º C ambient. Mechanical: Enclosure Dimensions (H x W x D approx.): SMP3CTX, SMP3PMCTX, SMP3PMP4, SMP3PMP4CB, SMP3PMP8, SMP3PMP8CB, SMP3PMP16, SMP3PMP16CB: 13.5 x 13 x 3.25 (342.9mm x 330.2mm x 82.6mm) - Accommodates up to two (2) 12VDC/7AH batteries. SMP3PMCTXX: 15.5 x 12 x 4.5 (393.7mm x 304.8mm x 114.3mm) - Accommodates up to two (2) 12VDC/12AH batteries. Power Supply Voltage Output Specifications:* Output VDC Switch Position Max. Load DC 12VDC SW1 - ON (Fig. 1c, pg. 5) 2.5A 24VDC SW1 - OFF (Fig. 1c, pg. 5) 2.5A *Specified at 25 C ambient. ON OFF - 24V ON - 12V - 2 - SMP3CTX Series

Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure s upper keyholes over the two upper screws; level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pgs. 7, 8). Secure enclosure to earth ground. 2. Slide [Power ON/OFF] switch t o OFF position. 3. Set SW1 on the power supply board to the desired DC output voltage (Fig. 1c, pg. 5) (Power Supply Voltage Output Specification Chart). 4. Connect AC power to the terminals marked [L & N], connect ground to the green flying lead (Fig. 1, pg. 5). Use 18 AWG or larger for all power connections (Battery, DC output). Use 22 AWG to 18 AWG for power-limited circuits (AC Fail/Low Battery reporting). 5. Slide [Power ON/OFF] switch to ON position. 6. Measure output voltage before connecting devices. This helps avoiding potential damage. CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment. There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel. 7. Slide [Power ON/OFF] switch t o OFF position. 8. Connect devices to be powered: a. For Power Supply Board connect to the terminals marked [ DC +]. b. For Power Distribution Module(s) connect devices to be powered to the terminal pairs 1 to 4 marked [1P & 1N] through [4P & 4N] (Fig. 2, pg. 6), 1 to 8 marked [1P & 1N] through [8P & 8N] (Fig. 3, pg. 6), or 1 to 16 marked [1P & 1N] through [16P & 16N] (Fig. 4, pg. 6), carefully observing correct polarity. Note: Power switch is used to disconnect the L (HOT) terminal from the rest of the board (Fig. 1a, pg. 5). When servicing the unit, AC mains should be removed. 9. When using stand-by batteries, they must be lead acid or gel type. Connect battery to the terminals marked [ BAT +] (battery leads included). 12VDC operation: Use one (1) 12VDC battery. 24VDC operation: Use two (2) 12VDC batteries connected in series. Note: When batteries are not used, a loss of AC will result in the loss of output voltage. For supervised models only: 10. Connect appropriate signaling notification devices to AC Fail and Low Bat supervisory relay outputs marked [NC, C, NO] (Fig. 1b, pg. 5). 11. Slide [Power ON/OFF] switch to ON position. LED Diagnostics: Power Supply Board Red (DC) Green (AC) Power Supply Status ON ON Normal operating condition. ON OFF Loss of AC. Stand-by battery is supplying power. OFF ON No DC output. OFF OFF Loss of AC. Discharged or no stand-by battery. No DC output. Power Distribution Module Green Power Distribution Module Status ON Normal operating condition. OFF No Power Output. SMP3CTX Series - 3 -

Power Supply Board: Terminal Identification: Terminal Legend Function/Description L, G, N Connect 115VAC/230VAC to these terminals: L to Hot, N to Neutral. DC + 12VDC / 24VDC @ 2.5A continuous output. *AC FAIL NC, C, NO *Low Battery NC, C, NO Used to notify loss of AC power, e.g. connect to audible device or alarm panel. Relay normally energized when AC power is present. Contact rating 1A @ 120VAC / 28VDC. Used to indicate low battery condition, e.g. connect to alarm panel. Relay normally energized when DC power is present. Contact rating 1A @ 120VAC / 28VDC. Low battery threshold: 12VDC output threshold set @ approximately 10.5VDC, 24VDC output threshold set @ approximately 21VDC. BAT + Stand-by battery connections. Maximum charge rate 0.5A. *Note: Supervised models only PD4/PD4CB/PD8/PD8CB/PD16W/PD16WCB - Power Distribution Module: Terminal Legend PD4/PD4CB PD8/PD8CB PD16W/PD16WCB Function/Description 1P to 4P 1P to 8P 1P to16p Positive DC power outputs. 1N to 4N 1N to 8N 1N to 16N Negative DC power outputs. Caution: Equipment to be installed / serviced by authorized / trained personnel only. Shut branch circuit power before installing / servicing equipment. WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes. The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel. - 4 - SMP3CTX Series

ON Fig. 1 Fig. 1a Switch disables power mains line voltage input. If stand-by battery (batteries) are connected, the DC output remains on OFF ON OFF ON 5A 250V Fig. 1b C FAIL NC C NO NC C NO Green Lead 115/230VAC power mains LOW BAT L G N AC FAIL NC C NO NC C NO --- BAT + --- DC + LOW BAT Power Supply Board AC DC See LED Diagnostics, pg. 3 OFF - 24V ON - 12V Power Distribution Module(s) ns Optional Rechargeable Stand-by Battery Optional Rechargeable Stand-by Battery ON OFF - 24V ON - 12V Fig. 1c SW1 12VDC - ON 24VDC - OFF SMP3CTX Series - 5 -

Fig. 2 - PD4/PD4CB Power Distribution Module(s): F1 F2 F3 F4 Used on PTC Models 1P, 2P, 3P, 4P = FUSED OUTPUTS 1N, 2N, 3N, 4N = COMMON OUTPUTS LED 1P 1N 2P 2N 3P 3N 4P 4N COMMON POWER OUTPUTS DC Output to devices INPUT From Power Supply Board (Factory Installed) Fig. 3 - PD8/PD8CB SW1 Used on PTC Models P 1 2 3 4 5 6 7 8 ON OFF D1 FUSED POWER OUTPUTS R1 LED N COMMON POWER OUTPUTS INPUT DC Output to devices From Power Supply Board (Factory Installed) Fig. 4 - PD16W/PD16WCB common outputs protected outputs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 N P Used on PTC Models S P P N N XFMR Input 3.5A 250V For continuous protection against risk of fire replace fuses with same type and rating. - 6 - SMP3CTX Series

Enclosure Dimensions (BC300): SMP3CTX, SMP3PMCTX, SMP3PMP4, SMP3PMP4CB, SMP3PMP8, SMP3PMP8CB, SMP3PMP16, SMP3PMP16CB 13.5 x 13 x 3.25 (342.9mm x 330.2mm x 82.6mm) Enclosure accommodates up to two (2) 12VDC/7AH batteries. 1.40 (36mm) 4.85 (123mm) 4.85 (123mm) 1.40 (36mm) 1.20 (31mm) 3.25 (83mm) 1.20 (31mm) 0.75 (19mm) 12.5 (318mm) 11.0 (279mm) 0.75 (19mm) 1.20 (31mm) 1.40 (36mm) 0.9375 (24mm) 1.40 (36mm) 5.10 (130mm) 5.10 (130mm) 13.0 (330mm) 5.10 (130mm) 6.5625 (167mm) 0.9375 (24mm) 3.25 (83mm) 3.25 (83mm) 3.25 (83mm) 1.0 (25mm) 1.0 (25mm) 1.0 (25mm) 10.5 (267mm) 1.0 (25mm) SMP3CTX Series - 7 -

Enclosure Dimensions (BC400): SMP3PMCTXX 15.5 x 12 x 4.5 (393.7mm x 304.8mm x 114.3mm) Enclosure accommodates up to two (2) 12VDC/12AH batteries. 4.615 (117.22mm) 4.615 (117.22mm) 1.75 (44.45mm) 1.375 (34.925mm) 1.125 (28.575mm) 1.25 (31.75mm) 4.5 (114.3mm) 1.1 (27.94mm) 12.23 (310.64mm) 1.1 (27.94mm) 4.5 (114.3mm) 1.25 (31.75mm) 0.91 (23.114mm) 0.91 (23.114mm) 2.0 (50.8mm) 15.5 (393.7mm) 2.0 (50.8mm) 5.0 (127.0mm) 5.0 (127.0mm) 1.25 (31.75mm) 1.1 (27.94mm) 0.79 (20.06mm) 1.25 (31.75mm) 1.75 (44.45mm) 4.615 (117.22mm) 4.615 (117.22mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA phone: 718-567-8181 fax: 718-567-9056 website: www.altronix.com e-mail: info@altronix.com Lifetime Warranty Made in U.S.A. IISMP3CTX Series C23R MEMBER - 8 - SMP3CTX Series