4HS MultiPower Submersible Pumps. Installation and Operating Manual.

Similar documents
4TCH Submersible Pumps. Installation and Operating Manual

4HS MultiPower Submersible Pumps. Installation and Operating Manual. M u l t i P o w e r. man4hs_mp_11_eng

4 submersible pumps with integrated electronics powered by renewable energy sources ENGLISH

4 submersible pumps powered by renewable energy sources

M u l t i P o w e r. CM MultiPower. Installation and Operating Manual

4 variable speed submersible pumps

Company name: Created by: Phone:

Sun Sensor setting in PumpScanner Daily output in average month 52 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

DIN W.-Nr AISI 304

Daily output in average month 77 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

SunSwitch setting in PumpScanner. Daily output in average month 219 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Daily output in May 32 m³

Water temperature: Dirt loss: Total dynamic head:

SunSwitch setting requirements min. 15 % Daily output in average month 154 m³

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

VASCO. Variable Speed Controller ENGLISH

Daily output in April 193 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Results of annual simulation

VSP solar Photovoltaic energy pumping systems. > we move itfaster > ENGLISH SMART

Example printout. Building project. SDC Example. Dyfi Eco Park SY20 8AX Machynlleth UK. Mr C. Laughton Phone:

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

ENG GENERAL DESCRIPTION

Yield Reduction Due to Shading:

4 variable speed submersible pumps

Available online at ScienceDirect. Energy Procedia 36 (2013 )

Eclipse Solar Suitcase

AeroVironment Universal Solar Pump Controllers

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

Yield Reduction Due to Shading:

User Manual 1.5KVA-3KVA INVERTER / CHARGER

User Manual 1KVA-5KVA INVERTER / CHARGER

GSM Series MPPT PV Controller. Version 1.0. Manual

Energy Produced by PV Array (AC):

Solar Hybrid Inverter SP Efecto Series

PRESENTATION. Pump solar water without battery 4HORAS

OFF GRID PV POWER SYSTEMS SYSTEM DESIGN GUIDELINES FOR THE PACIFIC ISLANDS

User Manual. Solar Charge Controller 3KW

PV Generation System. Solar Charge Controller SPECIFICATION

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

100kW GROUND MOUNTED SOLAR PHOTOVOLTIC POWER PLANT DETAILED PROJECT REPORT AERO SPACE MATERIALS PVT LTD

Power Conversion System The Best Technology for your photovoltaic and storage system

User Manual 1KVA-5KVA INVERTER / CHARGER

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Vunivau, Bua Province Vanua Levu, Fiji Solar Home System Design. Luis A. Vega, Ph.D.

Solar Hybrid Inverter SP Efecto Series

STONESTAR AUSTRALIA PTY LTD

SK-10. Features. Solar Charge Controller User Manual. Important Safety Information

Solar Inverter/Charger

SETEC Power Co.,Ltd

Switching DC Power Supply

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

SCC-MPPT Solar Charge Controller

TripleLynx Inverter Range MAKING MODERN LIVING POSSIBLE. The benchmark solar inverter from Danfoss 3 phase Transformerless 8, 10, 12.

SIZING OF SOLAR GENERATOR

SCC-MPPT Solar Charge Controller

INDEX. 3 BOREHOLE DC SOLAR PUMPS 3LLS...4 PERIPHERAL VANE DC SOLAR PUMP 3LSQB2...6

YSmart Technology Co., Ltd. User Manual. GTI Grid Series. GTI Series Inverters for Grid-connected PV system

Design Criteria Data

User Manual Solar Charge Controller 3KW

Naresuan University, Phitsanulok 65000, Thailand *Corresponding author ABSTRACT

Modeling and Comparison of Dynamics of AC and DC Coupled Remote Hybrid Power Systems

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

Design Criteria Data

Installation Manual. Opal Solar QSA Series

P H O T O V O LTA I C

Application of HOMER Software in Wind and Solar Resources Integration

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Design Criteria Data

Solar Hybrid Inverter SP Brilliant Series

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

TECHNICAL DATA SHEET KVA UPS Systemss

Design Criteria Data

DATASHEET PLECTRE - SOLAR CELL LIGHTING COLUMN

Design Criteria Data

Solar Charge Controller

Large scale solar power plant in Nordic conditions. Antti Kosonen, Jero Ahola, Christian Breyer, Albert Albó

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC

SCC-MPPT Solar Charge Controller

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

By: Ibrahim Anwar Ibrahim Ihsan Abd Alfattah Omareya. The supervisor: Dr. Maher Khammash

A 3-Year Case Study of a Residential Photovoltaic System with Microinverters

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

INSTALLATION MANUAL CRYSTALLINE SOLAR MODULES

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

K50. Technical Sheet

User Manual 1KW-5KW SOLAR INVERTER / CHARGER. Version: 1.2

SunRay Triangular. SunRay Triangular comes with tailored Smart City solutions, and is an ideal energy provider for streets and highways.

X600. Technical Sheet

Solar Pumps- High profitability and reliability lead to prosperity.

FlinSlim Lite Solar Hybrid Inverter 1KVA-5KVA USER MANUAL. Version: 1.3

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine

Up and Down Months of the Stock Market

3KW Off-grid Solar Power System LFP Battery

Photovoltaics. MPI Hybrid Series

Transcription:

4HS MultiPower Submersible Pumps. Installation and Operating Manual.

Index 1. Introduction to the 4HS MultiPower submersible pumps range... 3 2. Safety Instructions... 4 3. Stocking conditions... 4 4. Packing content... 4 5. General technical features... 5 6. Pump installation... 6 6.1 Installing pump in the well... 6 6.2 Installing pump in a solar pumping system... 7 6.3 Pump cable... 8 6.4 Water level sensing (only for helical rotor pump models)... 9 7. Sizing of a solar pumping system... 10 7.1 Pump selection... 10 7.2 PV panels number and wiring... 11 8. 4HS Models and performances... 12 9. Troubleshooting... 16 man4hs_mp_02_eng_solon.docx 2

1. Introduction to the 4HS MultiPower submersible pumps range 4HS MultiPower (4HS MP) is a 4 submersible pump for clean water composed by: three phase motor with wet rotor and canned type resin filled stator. Built-in inverter on board. Multi stage pump entirely made of AISI 304 stainless steel (centrifugal models) Helical rotor pump (helical rotor model) Pump driving made by inverter allows: Modify the pump speed. In this way the pump is operated only and when needed thus avoiding unnecessary waste of energy and granting longer system life. Implement the soft start and the soft stop to increase the system life and reducing the current peaks. Protect the motor from overloading and dry running, overvoltage, undervoltage and possible abnormal conditions. 4HS is used on residential and industrial sectors for water pressurized systems, granting: Energy saving. Simplified and quick installation. Long life reliability. 4HS MultiPower pumps can be fed both AC and DC with wide margins of operating voltage (90-265 VAC or 90-340 VDC). This means that the same pump can be powered by photovoltaic panels, by wind or diesel generator or by batteries. The hydraulic performance will be adjusted automatically according to the power source and the power available. In the application with photovoltaic panels an MPPT algorithm maximizes, for various conditions of irradiation and temperature, the electric power obtained from the panels thus the amount of water extracted. Pump speed is adjusted in relation to solar irradiation. When solar irradiation increases, pump will run faster thus pumping more water. When solar irradiation decreases (clouds moving or different hours of the day) pump will reduce its frequency and so delivery but it continues pumping till solar irradiation reaches the minimum value necessary for working. 4HS MultiPower pumps can be installed with or without the surface control module. When installed, the CM MultiPower monitors and records: Running hours. Input voltage, current and power. Alarms: dry running, overload, overvoltage. Digital inputs make it possible to connect a float switch, a pressure switch, a start and stop signal, etc... Running and alarm status are given by two digital outputs. Analogical inputs can be used to connect sensors (i.e. flow meter). 3

2. Safety Instructions The manufacturer strongly suggests to reading carefully this operation manual before using and installing its products Any operation (installation, maintenance and repair) must be carried out by trained, skilled and qualified personnel. Failure to observe and follow the instruction of this manual may result fatal in dangerous electric shock. The unit must be connected to the power supply by a switch granting the complete visual disconnection (separation) from the line before any operation. Disconnect the unit from the power supply before any operation. 4HS MP and pump system must be grounded properly before any operation. Do not start the pump for any reason if not completely immersed in water. Avoid any shock or serious impact during transportation. Damages due to transportation, incorrect installation, or improper use of the device will null and void the warranty. The manufacturer cannot be held responsible for any damage to people and/or property due to improper use of its products. 3. Stocking conditions Store the product on its packaging in a dry and well ventilated environment within a temperature range from -20 C and 70 C. If the pump remains in stock for more than a year is recommended to disassemble the rotating parts and test their functionality. It 'also need to power the electric pump (without running the motor) to allow charging of electrolytic capacitors of the inverter module. If the pump has already been put into operation and is then placed in storage, the minimum storage temperature is 4 C. Alternatively you need to add anti-freeze fluid. 4. Packing content Packing includes: 4HS Multipower submersible pump with 2,5 meters flat cable length. Cable junction kit. Operating Manual. Check the 4HS packing immediately upon delivery and check for damage and/or missing parts; in either cases immediately notify the supplier 4

5. General technical features PUMP 4HS MP Max. temperature of pumped liquid 35 C (92 F) Min. speed of water flow on motor case 0.2 m/s Characteristics of pumped liquid clean, non-corrosive, non-explosive, free of particles and fibers, with a maximum sand content of 50 g/m 3 Grade of protection IP68 Used Materials Pump and motor body in AISI 304 Cable Flat cable ACS KTM - WRAS approved Max. ambient temperature Control Module CM MP 50 C (140 F) Grade of protection IP55 (NEMA 4) Used Materials Aluminium, LCD membrane with PVC stickers, antipull plug in polyamide Analog input 2 x analog input 4-20 ma + 2 settable analog input 4-20 ma or 0-10 V. Digital input 4 inputs, N.O or N.C settable via software Digital output 2 output relays 5 A, 250 Vac, N.O. or N.C settable Auxiliary feeding 15 Vdc (300 ma),10 Vdc (5 ma) User display Backlit LCD display with 16 characters x 2 rows, 5 buttons, buzzer for acoustic Dimensions 180x180x120 mm Short circuit protection With fuse CERTIFICATIONS CE 5

6. Pump installation Entire installation procedure must be performed verifying that pump is not connected to the power supply. Pump can be installed both vertically and horizontally, but the outlet should never be below the horizontal line. Minimum head of 10% than max pump head must be granted. If the pump is not installed in a well, to grant a proper cooling, a cooling sleeve must be used; doing so the minimum speed of the pumped liquid has to be granted. 6.1 Installing pump in the well To reduce noise transmission it is advised to use plastic pipes. The pump must always be secured in the well through a special rope attached to loop on the pump head. It is recommended not to drop the pump in the well by using the electric cable, its integrity must be preserved in all operations. In this regard it is recommended to fix the cable on cable support or on the pipe. During operation the pump suction must always remains at least 1.5 meters below the dynamic water level. Do not drop the pump in the well by using the electric cable Make sure about the electric cable integrity during all the operations. Ensure the pump in the well with a stainless steel rope to be fixed to the hole in the pump head 6

6.2 Installing pump in a solar pumping system 4HS MultiPower pump can be installed with CM control module (optional) or not, so becoming plug-in operation. All protections of overload, overvoltage and dry running protection are integrated into the on board inverter. If the signal cables are connected to the CM control module, is possible to: Control the electric parameters (current, power, voltage). Record and store all the alarms related to the working hours Connect a pressure or a flow sensor to control the pump performances Connect a pressure or a float switch. Provide an alarm digital output for remote control 5 1. 4HS MultiPower 2. CM 3. PV panels 4. Tank 5. Float switch 4 3 2 1 7

6.3 Pump cable 4HS MultiPower are equipped, in their standard configuration, with 2,5 meter flat cable length. 4HS MP pump communicates with CM MP (surface control module) (if installed) by signal wires. If CM is not installed it s recommended to insulate signal wires. If the distance between the pump and the power supply is longer than the supplied cable it is necessary to make a junction performed by the special kit supplied as standard. The cable section for additional power conductors must be calculated considering the maximum allowed power loss. S: wire section [mm^2] : specific resistance = 0,018 [Ω mm^2/m] L: cable length [m] P1: pump electrical power [W]. V: voltage at maximum power. P: allowed power loss [%]. It is recommended not to exceed 3%. 8

To make the junction is necessary to follow carefully the instructions inside the kit. At the time of joining and electrical connection is essential to maintain the correspondence between the signal cables. After cable joining and placed the pump in the well you must perform, before connecting to power supply, a test of insulation: join together the two power cables and, applying a voltage of 500V, an insulation resistance from the ground higher than 100 Mohm must be verified. Join together the two signal cables and, applying a voltage of 500V, an insulation resistance from the ground higher than 100 Mohm must be verified. 6.4 Water level sensing (only for helical rotor pump models) WATER LEVEL SENSOR Water level sensing is based on variation of measured impedance. Keep it clean and not in direct contact with pipes in order to grant its function. 9

7. Sizing of a solar pumping system 7.1 Pump selection For the correct selection of a 4HS MultiPower pump, it is necessary to know: Desired daily water quantity. Total head (static + dynamic). Installation location. Working period (seasonal or year). Based on location it is possible to get from maps and tables (available in the web) the following values: a) Average daily radiation per year, minimum and maximum (KWh/m 2 ) b) Average daily radiation per months, minimum and maximum. c) Optimal tilt angle of the photovoltaic panels. Starting from daily radiation could be considered the number of hours with 1kW/m2, standard value to which PV panels performances are referred. Dividing the required water quantity by the number of hours of sun we can get the flow rate and in addition to the required head we can select the right pump. Latitude Longitude Daily delivery Qd [m3] Total head H [m] Daily average irradiance [kwh/m2] 1 kwh/m2 1 h @ 1kW/m2 Q [m3/h] = Qd / h 10

7.2 PV panels number and wiring The power rating of the selected pump (P1) defines the total power of the PV system to be adopted. The photovoltaic panels are characterized by: Rated power (Pmax) Rated voltage (Vmpp) Rated current (Impp) Open circuit voltage (Voc) P1/Pmpp will determine the number of panels needed. The panels are connected in series until the total open circuit voltage (Voc x n. Panels) does not exceed the voltage limit of the pump (400 VDC). Beyond this limit the panels are connected in parallel. The panels are connected in parallel as long as the current does not exceed the current limit of the pump (16 A). Sizing : example Daily delivery Qd = 26 m 3 Total head H = 50 m Location : Mossano, Vicenza, Italia Latitude: 45 25 Longitude: 11 33 Optimal tilt angle is 35 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Year kwh/m 2 1,54 2,44 3,72 4,81 5,81 6,34 6,39 5,42 4,16 2,69 1,73 1,19 3,85 If the pump is used the full year, have to be considered the average daily radiation per year that is 3,85 kwh/m2 (3,85 h @ 1kW/m2) and, considering the required daily delivery Qd, a pump granting 26/3,85 = 6,75 m3/h should be selected. If the pump is used only in the summer (June, July, August), have to be considered the average daily radiation for the selected months that is 6,05 kwh/m2 (6,05 h @ 1kW/m2). * Sizing considering photovoltaic panels of 240 Wmpp, nominal voltage 30 Vmpp, nominal current 8 Impp, no load voltage 38 Voc. Year Summer Q [m 3 /h] 6,75 4,3 H [m] 50 50 4HS MultiPower 06/04 04/03 P1 [W] 2600 2000 PV panels * 12 9 Series 6 9 Parallel 2 0 11

8. 4HS Models and performances 50 40 3,5 3 2,5 4HS 02/02H MP 66 ft 20 m 30 m 40 m 50 m 98 ft 131 ft 60 m 164 ft 197 ft 70 m 230 ft 80 m 262 ft 295 ft 90 m 328 ft 100 m Q [l/min] 30 Q [m^3/h] 2 1,5 20 1 10 0,5 0 0 P1 [W] 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 14 12 4HS 02/02H MP 66 ft 98 ft 131 ft 164 ft 197 ft 230 ft 262 ft 295 ft 328 ft 10 Q [U.S.gpm] 8 6 4 2 0 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 P1 [W] Model Voltage Max. absorbed current Power factor Max absorbed power Length Delivery Pump weight Max. diameter Packing size Total weight 4HS [A] P1 [W] [mm] [kg] [mm] [cm] [Kg] 02/02H MP 90-340 VDC 90-265 VAC 10 (130 VDC) 10 (130 VAC) 1 1300 1350 1 1/4 19,5 101 ** 120x20x29 20,5 ** including cable guard 12

Model Voltage Max. absorbed current Power factor Max absorbed power Length Delivery Pump weight Max. diameter Packing size Total weight 4HS [A] P1 [W] [mm] [kg] [mm] [cm] [Kg] 02/04 MP 90-340 VDC 90-265 VAC 16 (130 VDC) 16 (130 VAC) 1 2100 936 1 1/4 19,5 101 ** 120x20x29 20,5 02/08 MP 90-340 VDC 90-265 VAC 16 (220 VDC) 16 (220 VAC) 1 3500 1065 1 1/4 22 101 ** 120x20x29 23 13

Model Voltage Max. absorbed current Power factor Max absorbed power Length Delivery Pump weight Max. diameter Packing size Total weight 4HS [A] P1 [W] [mm] [kg] [mm] [cm] [Kg] 04/03 MP 90-340 VDC 90-265 VAC 16 (150 VDC) 16 (150 VAC) 1 2400 915 1 1/4 19,4 101 ** 120x20x29 20 04/05 MP 90-340 VDC 90-265 VAC 16 (207 VDC) 16 (207 VAC) 1 3300 1002 1 1/4 21 101 ** 120x20x29 22 14

Model Voltage Max. absorbed current Power factor Max absorbed power Length Delivery Pump weight Max. diameter Packing size Total weight 4HS [A] P1 [W] [mm] [kg] [mm] [cm] [Kg] 06/02 MP 90-340 VDC 90-265 VAC 16 (130 VDC) 16 (130 VAC) 1 2100 894 1 1/2 19,5 101 ** 120x20x29 20,5 06/04 MP 90-340 VDC 90-265 VAC 16 (225 VDC) 16 (225 VAC) 1 3600 981 1 1/2 21,4 101 ** 120x20x29 22 15

9. Troubleshooting If the pump, after the installation and power supply connection, doesn t provide any water please verify: correct wiring. voltage conditions (90 340 VDC, 90 265 VAC). enough power available (solar irradiance). water presence:if pump during operation runs dry, an alarm occurs and pump will stop. Every 5 minutes pump will attempt to restart the operation after 5 minutes. 16

SOLON S.p.A. Via dell Industria e dell Artigianato 2 35010 Carmignano di Brenta PD Italy Phone + 39 049 9458200 Fax + 39 049 9458299 E-Mail components.it@solon.com For more information on SOLON products please visit www.solon.com