ASL09..S 3-pole Contactors - Spring Terminals

Similar documents
NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

AF40... AF96 3-pole contactors Technical data

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

TAE pole Contactors

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Short form catalogue. Motor protection & control

AE 9... AE 40 Contactors NE... Contactor Relays

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Star Series Motor protection & control

Description. Positive safety relays

Auxiliary contact blocks - with spring terminals Accessories

B Mini Contactor V Hz

Electronic overload relays EF205 and EF370

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Electronic overload relay EF65, EF96 and EF146

Motor Starting Solutions Open Type Version, in Kit Form

Mini contactors B6, BC6 with 3 pole

Accessories for Contactors and Contactor Relays

3 Pole, 27 Amp, Non-Reversing Across The Line Contactor With V Ac Coil and 1 No Auxiliary Contact

Micro Contactor MA Series

Industrial Contactors CTX 3 3P 185A - 800A

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

BC Mini Contactor VDC

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Contactors type AF1350-AF1650

Controls. CONTACTORS CWB Line (up to 40A)

Thermal overload relay TF140DU and TF140DU-V1000

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

MS General Information Extended Product Type: MS

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

CI-TI Contactors and motor starters Types CI 61 - CI 98

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Meta Solution. Contactors and Overload relays

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

Thermal overload relay TF65 and TF96

55 Series - Miniature General Purpose Relays 5-10 A

Application Mini Contactors for Motors and Resistive Loads

SIRIUS 3RU2 Thermal Overload Relays

Manual Motor Starters. Meta-MEC

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Manual motor starter magnetic only MO325

US Catalog. Motor protection and control AF Range contactors & overload relays

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Thermal Overload Relays

FMotor Circuit Controllers

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

KT4 Manual Motor Starter

BETA Switching Switches and Light Indicators

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Limit Switches - Limit Type (PS21L) Metal Body IP66

Ideal for use as a manual starter

Low Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays

Manual motor starter MS132

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Manual motor starter MS132

Technical Information

Short form catalogue Motor protection and control Block contactors and overload relays

Switches Unlimited Phone: * Fax:

Solid State Relays, 3-phase

Page 2-4 Page 2-8. Page Page 2-13

Manual motor starter MS116

Thermal overload relays Type TA Class 10

3 - Protection components Motor circuit-breakers

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Manual motor starter MS132

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

AF series contactors (9 2650)

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65

Quality Products, Prompt Service, Trustful Relationships.

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Manual Motor Starters

DIN EN UL 508 / CSA 3RF A A 0 2

4 - Miniature controls

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Modular contactor for installation into distribution boards

Transcription:

4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil terminals (A1+ and A2-) must be respected, - Rail-mounted, no tools required, - Additional surge suppressor which does not increase overall dimensions. Main accessories available: - Up to 2 add-on CA3..S 1-pole auxiliary contact blocks, - VM3 mechanical interlock unit without additional width, - RV5 or RT5 surge suppressor. IEC AC-3 rated operational power 4 kw 400 V UL/CSA 3-phase motor power 5 hp 440-480 V culus CCC CE Ordering Details Main poles + Built-in aux. contacts A1+ A2 - A1+ A2-1L1 3L2 5L3 2T1 4T2 6T3 1L1 2T1 3L2 4T2 5L3 6T3 13 NO NO 14 21 NC NC 22 For other coil voltage see 1SBC101023S0201.pdf Control coil voltage Type Order code Pack (ing) Weight DC pieces kg (1 pce) 24 V ASL09-30-10S-81M 1SBL 103 004 M8110 40 0.28 48 V ASL09-30-10S-83M 1SBL 103 004 M8310 40 0.28 110 V ASL09-30-10S-86M 1SBL 103 004 M8610 40 0.28 220 V ASL09-30-10S-88M 1SBL 103 004 M8810 40 0.28 24 V ASL09-30-01S-81M 1SBL 103 004 M8101 40 0.28 48 V ASL09-30-01S-83M 1SBL 103 004 M8301 40 0.28 110 V ASL09-30-01S-86M 1SBL 103 004 M8601 40 0.28 220 V ASL09-30-01S-88M 1SBL 103 004 M8801 40 0.28 Mounting positions Main For complete technical data see.pdf Main poles Rated operational voltage U e max. 690 V IEC AC-3 Utilization category (for 1500 r.p.m., 50 Hz or 1800 r.p.m., 60 Hz, 3-phase motors) for air temperature close to contactor θ 55 C AC-3 rated operational power 400 V 4 kw I e / AC-3 max. rated operational current 400 V 9 A I e / AC-1 rated operational current 20 A (Ue max. 690 V, 50/60 Hz for air temperature close to contactor θ 40 C) I e / AC-8a rated operational current 12 A (without thermal overload relay - Ue 400 V - θ 40 C) UL/CSA 3-phase motor (for 1500 r.p.m., 50 Hz or 1800 r.p.m., 60 Hz) Motor power 440-480 V 5 hp Amp rating 440-480 V 7.6 A General use Amp rating 600 V 12 A Magnet system Coil operating limits (acc. to IEC 60947-4-1) 0.85... 1.1 x U c (θ 60 C) Average pull-in coil consumption value 3 W Average holding coil consumption value 3 W Built-in aux. contacts Rated operational voltage U e max. 690 V IEC I e / AC-15 rated operational current 400-415 V 3 A acc. to IEC 60947-5-1 I e / DC-13 rated operational current 24 V DC 6 A (144 W) UL/CSA Pilot duty A600, Q300 Max. electrical AC-3 1200 cycles/h switching frequency AC-1 600 cycles/h Connecting Main pole terminals Rigid capacity Flexible with AWG 1 or 2 AWG 18-12 Coil and built-in Rigid auxiliary contact Flexible with terminals AWG 1 or 2 AWG 18-14 Degree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 IP 20 Pos. 2 +30-30 Pos. 4 Pos. 3 45 1.77" 7 0.28" 72.5 2.85" 10 0.39" 2 x M4 8-32 UNC 35 1.38" ø 4.2 0.17" Pos. 5 Pos. 1 Pos. 1 ± 30 68 2.68" 35 mm EN/IEC 60715 5.5 0.22" 60 2.36" Dimensions: mm, inches 1SBC101008S0202 15

Main Pole - Utilization Characteristics according to UL/CSA NEMA size 00 00 0 00 00 00 General use rating Amp rating 600 V A 20 20 20 12 12 15.2 3-phase motor rating Amp rating M 3 200-208 V A 7.8 7.8 11 7.8 7.8 11 220-240 V A 6.8 9.6 15.2 6.8 9.6 15.2 440-480 V A 7.6 11 14 7.6 11 14 550-600 V A 9 11 11 9 11 11 Motor power 200-208 V hp 2 2 3 2 2 3 M 220-240 V hp 2 3 5 2 3 5 1500 r.p.m. 50 Hz 3 1800 r.p.m. 60 Hz 440-480 V hp 5 7 1/2 10 5 7 1/2 10 3-phase motors 550-600 V hp 7 1/2 10 10 7 1/2 10 10 Short-circuit protection for contactors without thermal O/L relay - Motor protection excluded Fuse rating A 40 50 60 40 50 60 Fuse type, 600 V J 1-phase motor rating Amp rating 120 V A 7.2 9.8 13.8 7.2 9.8 13.8 240 V A 8 10 12 8 10 12 Motor power 120 V hp 1/3 1/2 3/4 1/3 1/2 3/4 240 V hp 1 1 1/2 2 1 1 1/2 2 Max. electrical switching frequency for general use cycles/h 600 for motor use cycles/h 1200 General Rated insulation voltage U i according to IEC 60947-4-1 V 690 according to UL/CSA V 600 Rated impulse withstand voltage U imp. kv 6 Standards Devices complying with IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 Air temperature close to contactor without thermal O/L relay C -40... +70 for storage C -60... +80 Climatic withstand Category B according to IEC 60947-1 Annex Q Operating altitude m 3000 Shock withstand acc. to IEC 60068-2-27 and EN 60068-2-27 Mounting position 1 1/2 sinusoidal shock for 11 ms: no change in contact position AS contactors - AC operated ASL contactors - DC operated C1 Shock direction Closed position Open position Closed position Open position A 20 20 20 10 A A B1 B2 B1 10 5 15 5 B2 15 15 10 10 C2 C1 20 9 15 8 C2 20 14 14 8 Mounting positions Pos. 2 +30-30 Pos. 4 Pos. 3 Pos. 1 Pos. 1 ± 30 Mounting distances The contactors can be assembled side by side Fixing on rail acc. to IEC 60715 and EN 60715 35 x 7.5 35 x 15 with screws (not supplied) 2 x M4 screws placed diagonally Pos. 5 22

Built-in Auxiliary Contacts - Utilization Characteristics according to IEC Rated operational voltage U e max. V 690 Conventional free air thermal current I th θ < 40 C A 10 Rated frequency limits Hz 25... 400 Rated operational current I e / AC-15 acc. to IEC 60947-5-1 24-127 V 50/60 Hz A 6 220-240 V 50/60 Hz A 4 400-415 V 50/60 Hz A 3 500 V 50/60 Hz A 2 690 V 50/60 Hz A 2 Rated operational current I e / DC-13 acc. to IEC 60947-5-1 24 V DC A / W 6 / 144 48 V DC A / W 2.8 / 134 72 V DC A / W 1 / 72 110 V DC A / W 0.55 / 60 125 V DC A / W 0.55 / 69 220 V DC A / W 0.3 / 66 250 V DC A / W 0.3 / 75 Making capacity acc. to IEC 60947-5-1 10 x I e AC-15 Breaking capacity acc. to IEC 60947-5-1 10 x I e AC-15 Short-circuit protection gg type fuse A 10 Rated short-time withstand current I cw for 1.0 s A 100 for 0.1 s A 140 Minimum switching capacity V/mA 12 / 3 with failure rate acc. to IEC 60947-5-4 10-7 Non-overlapping time between N.O. and N.C. contacts ms 1.5 Heat dissipation per pole at 6 A W 0.1 Built-in Auxiliary Contacts - Utilization Characteristics acc. to UL/CSA Max. rated voltage 600 V AC, 250 V DC Pilot duty A600, Q300 23

Magnet System Characteristics for AC Operated Contactors Rated control circuit voltage U c - at 50 Hz V 24... 415 - at 60 Hz V 24... 415 Coil operating limits acc. to IEC 60947-4-1 0.85... 1.1 x U c (at θ 60 C) ; U c (at θ 70 C) Drop-out voltage in % of U c approx. 30... 50 % Coil consumption Average pull-in value 50 Hz VA 33 60 Hz VA 33 50/60 Hz VA 33 Average holding value 50 Hz VA / W 6.5 / 1.5 60 Hz VA / W 5 / 1.2 50/60 Hz VA / W 6.5 / 1.5 Operating time between coil energization and: N.O. contact closing ms 9... 24 N.C. contact opening ms 6... 18 between coil de-energization and: N.O. contact opening ms 5... 19 (1) N.C. contact closing ms 7... 22 (1) (1) The use of RC5-1 surge suppressor increases opening time by a factor of 2 to 3. Magnet System Characteristics for DC Operated Contactors Contactor types: Rated control circuit voltage U c V DC 12... 240 Coil operating limits acc. to IEC 60947-4-1 0.85... 1.1 x U c (at θ 60 C) ; U c (at θ 70 C) Drop-out voltage in % of U c approx. 10... 40 % Coil consumption Average pull-in value W 3 Average holding value W 3 Coil time constant open L/R ms 12 closed L/R ms 40 Operating time between coil energization and: N.O. contact closing ms 36... 59 N.C. contact opening ms 31... 53 between coil de-energization and: N.O. contact opening ms 13... 17 (2) N.C. contact closing ms 15... 20 (2) (2) The use of RT5 surge suppressor increases opening time by a factor of 1.1 to 1.2. 24

Connecting Characteristics M3 with cable clamp Delivered in open position. Screws of unused terminals must be tightened. Connecting capacity (min.... max.) Main conductors (poles) Rigid solid 1 x mm² 0.75... 4 0.75... 2.5 2 x mm² 0.75... 4 0.75... 2.5 Flexible with noninsulated 1 x mm² 0.75... 2.5 0.75... 2.5 Flexible with insulated 1 x mm² 0.75... 2.5 0.75... 1.5 2 x mm² 0.75... 1.5 0.75... 1.5 Bars and lugs L mm 7.7 - l L l mm > 3.2 - Capacity acc. to UL/CSA 1 or 2 x AWG 18-12 18-12 Auxiliary conductors (built-in auxiliary terminals + coil terminals) Rigid solid 1 x mm² 0.75... 2.5 0.75... 2.5 Flexible with noninsulated 1 x mm² 0.75... 2.5 0.75... 2.5 Flexible with insulated 1 x mm² 0.75... 2.5 0.75... 1.5 2 x mm² 0.75... 1.5 0.75... 1.5 Bars and lugs L mm 7.7 - l L l mm > 3.2 - Capacity acc. to UL/CSA 1 or 2 x AWG 18-14 18-14 Degree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 IP 20 IP 20 Screwdriver type Flat Ø 6.5 / Pozidriv 2 Flat Ø 3.5 Stripping length mm 9 10 Tightening torque All terminals recommended Nm / lb.in 1.00 / 9 - max. Nm 1.20-25