WELCOME TO MAGNATROL

Similar documents
WELCOME TO MAGNATROL

High Pressure Solenoid Valves

Prices Effective April 1, 2017 PRICE BOOK * CHECK ONLINE FOR PRICE BOOK UPDATES

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Vacuum Relief Performance Curves

Constructions Suitable for -40 C to -50 C Ambient

Product Manual. EX40, Version Last Updated: 11/7/16. Product Description:

Solenoid Valves Catalogue

GVI Series Industrial Globe Valves for Flow Control

3 Way/2 Position Valves

check valves BIVCO Check Valves

2-Way/2 Position Valves

Specifications. Body Materials: Carbon steel, stainless steel, chrome-moly steel, other castable alloys

Size: 1/4 to 3. Material: 316 Stainless Steel, Carbon Steel,

Installation, Operation and Maintenance Manual

Constructions Suitable for -40 C to -50 C Ambient. 2, 3 and 4 Way Constructions Available. Brass, Aluminum and Stainless Steel Bodies

PROCESS & AUTOMATED VALVES

GATE VALVES ALV-1 FORGED STEEL NOMINAL PRESSURE NOMINAL SIZE MATERIALS CONNECTIONS. ANSI Class PN /4-2 DN 8-50.

Modulating Water Valves and Bulb Wells

SECTION VALVES

SECTION Pressure & Temperature Control

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F

D I V I S I O N O F M A R S H B E L L O F R A M

GACHOT TYPE V16 BALL VALVES CARBON STEEL / FULL BORE / DN 8 TO DN 150

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES

15100 VALVES. E. Section Building Automation and Control System Guidelines

P95H Regulator Applications P95H Part Matrix Specifi cations Materials of Construction P95H Flow Coeffi cients Wide Open Coeffi cients

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE

ACCESSORIES 204 ACCESSORIES

RESILIENT SEATED BUTTERFLY VALVES. Howell Valve & Automation. Toll Free: Howellvalve.com

SOLENOID CONTROL VALVE

Gasket

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

Sizes 1/4" through 4" Medium Throttling Band

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance

4 qwer. Steam and Hot Water Valves 2/2 SERIES. Hot Water/ Steam. Features. Construction. Nominal Ambient Temperature Ranges: Electrical.

Specifications. Body Materials: Carbon steel, stainless steel, chrome-moly steel, other castable alloys

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves

Bourdon Tube Pressure Switches

A. This Section includes general duty valves common to several HVAC piping systems.

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

SECTION VALVES PART 1 - GENERAL

April 2007 / BULLETIN Solenoid Valves. The right solenoid valve for any job.

Solenoid Valves for General Purpose 2 Ways

Deep Well Pump Control Valve

Crispin Valves Operating Guide. Crispin

Titan Check Valves. Call. Fax. . Visit. Titan Flow Control. Your Pipeline to the Future

Cash Valve B SERIES PRESSURE REGULATORS. ISSUED - JANUARY 1999 CAVMC-0509-US-0208 ISO 9001 Certified

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A

Be llows-se aled Valve s

2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

Electronic Control Valves

SOLENOID VALVES no voltage release (lever type) manual reset construction 1/4 to 1/2

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Oil and Gas Products Pressures to 30,000 psi

4 N E X T G E N E R A T I O N

Direct solenoid and solenoid pilot operated valves

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT.

International Standard Valve, Inc. Trunnion Mounted Ball Valve

SECTION MISCELLANEOUS VALVES

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

FLANGED BALL VALVES ASME CLASS 150 & 300

SECTION FACILITY FUEL OIL PIPING

Booster Pump Control Valve

Hoffman Specialty Service Parts Catalog PARTS LIST HS-800C

MARINE INERGEN 150-BAR SYSTEMS Component Sheet Library

Heat Exchanger Accessories

2/2 ) % ) % ) Assemblies. Solenoid and Piloted Piston Valve Series Condensate Drain Valve Assemblies. Brass or Stainless Steel Bodies 1/4" to 1" NPT

/2. Hot Water and Steam Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT ^ % )

packless valves Packless Valves Index Bellows & Diaphragm

Specifications, Applications, Service Instructions & Parts. Flanged and Weld-in 3/4" thru 4" Port (20 mm thru 100 mm) for Refrigerants

Valve Selection. 1. Function and service considerations

Solenoid Valves Magnetic Level Switches

EH50 Product Manual Version

ID & IP SERIES IN-LINE DISC AND PISTON VALVES

Control & Power, Inc

CASH VALVE B SERIES PRESSURE REGULATORS

ALC-3 BUTTERFLY VALVES NOMINAL PRESSURE NOMINAL SIZE MATERIALS CONNECTIONS DESIGN. ANSI Class PN DN

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY

Iron Horse ED Series Pressure Regulator

STYLE B THERMOSTATIC TEMPERATURE REGULATOR

Table of Contents. Automatic Section A B V. Coil Piping Packages A B P P. Water Source Heat Pump Hose Kits A B H K

SECTION VALVES PART 1 -GENERAL

Condensed Catalog 410A January 2008

Hose Length Custom Length Supply Line Options Ball Valve w/ PT UBY Strainer w/ PT and BDV

Operating Instructions. Valves Atkomatic Series ATEX and Series ATEX Series Series

FILTERS, STRAINERS AND VALVES PRODUCT GUIDE

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W

Fire Protection Products LLC

Sinclair Collins. Process Control Valves. For Steam, Hot and Cold Liquids -40 to 450 F up to 500 psi. Catalog SCV-100/USA April 2001

Weksler Accessories STATIONARY RED SET HAND OVERLOAD STOP SPECIAL DIAL MAXIMUM POINTER VACUUM STOP

Transcription:

Catalog 6

BULLETIN 6-INDEX WELCOME TO MGNTROL Process Control Solenoid Valves For Water Oil ir Gas Steam Cryogenics Vacuum Solvents Brine Oxygen Corrosive Fluids Magnatrol Valve Corp. Established 1936 Experienced Dedicated Sales Staff pplication / Engineering ssistance Excellent Product Support Quick Delivery Our continued success has come from manufacturing a top quality product, product support, commitment to service and on-time delivery assuring complete customer satisfaction. Our Products Every valve is manufactured and tested in-house following Quality ssurance Standards where production operations are under the control of our dedicated, experienced staff and workforce. High Quality Bronze and Stainless Steel Solenoid Valves* Pressures up to 0 * Temperatures up to 400 F * Cryogenic and Oxygen Service pplications Normally Closed (Energize to Open) Normally Open (Energize to Close) Continuous Duty Coils for all C & Voltages NO Differential Pressure Required to Open Full Port-Internal Pilot Operated or Direct cting -Way Straight Thru Design Packless Construction * Custom Engineered Valves, Special lloys, Temperatures, Pressures and pplications as well as Modifications to Standard Magnatrol Valves are available through Magnatrol s Clark-Cooper Division. (See bottom of page 3) TBLE OF CONTENTS Category Pages(s) Coils................................... 4 Construction Features.................. 5 Bronze Valves N & NR.......................6 & 7 & R.......................8 & 9 M & MR.................... 10 & 11 S & SR..................... 1 & 13 L & LR...................... 14 & 15 G & GR..................... 16 & 17 D.............................18 Strainers...............................19 Stainless Steel Valves K & KR..................... 0 & 1 W & WR.................... & 3 Optional Features................... 4 & Ordering Information............... 6 & 7 Terms & Conditions/Contact Info....... 8 DDITIONL CTLOGS Technical/Engineering Catalog.. 6-ENG Technical & Engineering Data including: Sandy Well Water Valves Gritty Coolant Valves Universal Mount Catalog.........6-UM Valves can be mounted in any position Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077

BULLETIN 6-VLVE SELECTION CHRT VLVE SELECTION CHRT Ordering Information - See Pages 6 & 7 For Optional Features - See Pages 4 & VLVE SELECTION CHRT (For Fluids/Gases Not Listed nd For Special pplications, Consult Factory) Max. Temperature Up To 1 F Up To 400 F Construction Bronze Stainless Steel Valve Type D G/GR N/NR /R M/MR S/SR L/LR K/KR W/WR Page 18 16 & 17 6 & 7 8 & 9 10 & 11 1 & 13 14 & 15 0 & 1 & 3 Pressure 30 0 1 180 0 0 180 3/8-1 -3 - -3 3/8 - -3-3 -3-3 Internal Port Full Full Reduced Full Reduced Full Full Full Full ir t t t t t t t Brine t t t t t Gas t t t t t t Oil t t t t t t Solvents t t t t t t t Water t t t t t t t Vacuum t t t t Steam t t t Cryogenic t t t Oxygen, Liquid t t t Oxygen, Gaseous t t t t t Corrosive t Use the chart above to determine suitable types of Magnatrol valves for a given application. Example: normally closed valve for use on 100 psi steam, there are three types suitable and the final selection can only be made after referring to Bulletins 6-M, 6-S and 6-W on pages 10, 1 and respectively. Maximum Differential Pressure: When specifying a valve, the Maximum Differential Pressure must be equal to or greater than the application. Care should be taken not to over specify the valve by choosing a valve with a Maximum Differential Pressure that is excessively beyond the application. If you are unsure please consult the factory. -Way and 3-Way 1/4 Thru 6 Pressures to 10,000 Temperatures up to 5 F Dirty / Viscous & Corrosive Fluids Bronze, 316SS, Monel, lloy 0 & Hastelloy 3-Valve Manifold for CNG Refueling End connections: NPT, Flange, Union, Socket Weld, Butt Weld, Nipples etc. Options: Remote Trip with Manual or utomatic Reset and many others Designs for Navy and Marine Service High Pressure Cartridge Valve 10,000 3-Way Trip Valve with Position Indicating Switches and Manual Reset Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077 3

BULLETIN 6-COIL SOLENOID COILS CONTINUOUS DUTY COILS ELECTRICL CHRCTERISTICS Coils are stocked for the following voltages: Voltage 6 1 4 3 48 64 75 10 08 40 480 575 * *, 60 Hertz C 75V for locomotive applications * Furnished with surge protecting capacitor Reference should be made to the Bulletins to determine the availability of a required valve for a specific power supply. Consult the factory for information regarding voltage and frequencies not listed. ENCPSULTED COIL Valves for.c. service can be converted for use on other.c. voltages simply by changing the coil. Similarly D.C. valves can be converted for other D.C. voltages. Consult factory regarding conversion from.c. to D.C. or D.C. to.c. CURRENT CONSUMPTION: Current values shown in the bulletins are for 10 volts, 60 hertz. For other voltages the current is inversely proportional: For instance, if a given valve draws 0.5 amperes on 10 volts it would draw 0. amperes on 40 volts, or 0.1 amperes on 480 volts. Where power consumption is shown in D.C. watts, the values given should be divided by line voltage to obtain the current in amperes. Power consumption for all valves is shown in the individual bulletins. CONSTRUCTION: Continuous Duty Construction: Coils can be energized continuously without overheating or failure. Wire Leads: 18 long 18 gauge wire standard (longer continuous leads available) Encapsulated: Coils are encapsulated for temperature of intended service, providing excellent resistance to shock, moisture, oil and chemicals COIL CLSS: GENERL SERVICE - CLSS B INSTLLTION: The coil is a two wire device which may be controlled by either a single or double pole switch. The switch should always be installed in the hot leg of 10 volt circuits. Where both legs are hot, such as 40 or 480 volt circuits, a double pole switch is preferable, however, if a single pole switch is used, then the wiring should have top quality insulation since even minute leakage currents may give rise to sticking problems. On motor hookup with step control starter, full voltage should be supplied to coil immediately. Note: Coil can be readily changed while valve is still under pressure. HIGH TEMPERTURE - CLSS H Maximum Fluid Maximum mbient Maximum Fluid Maximum mbient Temperature Temperature Temperature Temperature 1 F (413 C) 104 F (40 C) 400 F (06 C) 1 F (100 C) 4 Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077

BULLETIN 6-CONSTRUCTION VLVE CONSTRUCTION FETURES Valve Construction Features: -way straight thru globe design Bronze or Stainless Steel body w/ female NPT threads standard Stainless Steel available with 1# and # flanged ends Full port-internal pilot operated or direct acting Packless construction Continous duty coils for all voltages No differential pressure required to open Easy In-Line Service Inspect, clean or service all internal parts of full port-internal pilot operated or direct acting while the valve body remains in the pipeline shortening costly down time and increasing productivity. HOUSING Construction: Malleable or Cast Iron Designed for rugged industrial use Self contained terminal box with NPS conduit connection COIL vailable Class B or H insulation Designed for continuous duty service vailable in most C or voltages Coil Enclosure vailable: NEM 1, 4, 4X and Explosion Proof Conduit Boss Coil BONNET PISTON SSEMBLY sturdily constucted stem assembly consisting of a plunger and stainless steel pilot flexibly connected to the piston Discs are available in various materials dictated by operating conditions flanged metallic tube encloses the plunger and hermetically seals the top of the valve VLVE BODY Constructed of high pressure cast bronze or stainless steel in a globe pattern with screwed ends* Bonnet Piston Valve Disc Disc Nut Bonnet Ring Plunger Valve Spring Pilot Valve Valve Body Normally Closed Valve shown is typical of Type, thru 1-1/4 vailable in a full range of sizes * Stainless Steel valves available with flanged ends. Flanged Bronze valves available through Magnatrol s Clark- Cooper Division (See bottom of page 3). MGNTROL SOLENOID OPERTED VLVES are used to control the flow of liquids or gases, generally in conjunction with automatic control apparatus such as thermostat, float switch, time switch, or flow meter. Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077 5

BULLETIN 6-N BRONZE SOLENOID VLVES MX. FLUID TEMP. 1 F MX. STTIC PRESSURE FOR OPTIONS & CCESSORIES SEE PGES 4 & TYPE N - NORMLLY CLOSED TO PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN DIRECT CTING - ORIFICE SIZES 3/3 TO Valve opens when energized and closes when de-energized. In this direct acting valve, when the coil is energized, the stem is lifted from its conical seat by the plunger. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPS conduit conn. *Valve Stem - 303 Stainless Steel *Spring - 30 Stainless Steel *Body Seal - Buna N *Orifice Seal - Metal to Metal *C Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, 18 leads - (Class H available) To control the flow of Water, Oil, ir, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 3/8 Valve Port C DISCONTINUED -- USE VLVE WITH BUSHING Dimensions In 3/8 18N 1/4 18N4 75 3/16 18N5 0.4 1. 18 6 6-1/4 5-3/8 - - 100 5/3 18N8 1 1/8 18N6 3/3 18N7 3/8 33N 75 5/16 33N3 100 1/4 33N4 45 0.8.4 3 10 7-1/8 6-3/8 3- - 1 3/16 33N5 1/8 33N6 15 18N13 35 5/16 18N33 0.4 1.3 18 7 6-5-5/8 - -7/8 30 33N13 45 0.8.5 3 10 7-3/8 6-3- -7/8 75 5/16 33N33 Voltage (C or ) Temperature (See pages 4 & ) 6 Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077

BULLETIN 6-NR BRONZE SOLENOID VLVES TYPE NR - NORMLLY OPEN TO PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN DIRECT CTING - ORIFICE SIZES 3/3 TO Valve closes when energized and opens when de-energized. In this direct acting valve, when the coil is energized, the stem is pressed into its conical seat by the plunger. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPS conduit conn. *Poppet - 304 Stainless Steel *Stem - 303 Stainless Steel *Spring - Inconel *Body Seal - Buna N *Orifice Seal - Metal to Metal *C Shading Coil - Copper *Stem Pin - 304 Stainless Steel Coil - Encapsulated Class B, 18 leads - (Class H available) To control the flow of Water, Oil, ir, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. MX. FLUID TEMP. 1 F MX. STTIC PRESSURE FOR OPTIONS & CCESSORIES SEE PGES 4 & 3/8 Valve Port C DISCONTINUED -- USE VLVE WITH BUSHING Dimensions In Voltage (C or ) Temperature (See pages 4 & ) 3 3/8 18NR 45 1/4 18NR4 70 3/16 18NR5 90 5/3 18NR8 0.5 1.5 18 7 7 6-1/8 - - 135 1/8 18NR6 3/3 18NR7 45 3/8 33NR 70 5/16 33NR3 90 1/4 33NR4 45 1.0.7 3 10 7-7/8 7-1/8 3- - 135 3/16 33NR5 70 1/8 33NR6 13 18NR13 3 5/16 18NR33 0.5 1.6 18 7 7-1/4 6-3/8 - -7/8 7 33NR13 70 5/16 33NR33 45 1.0.8 3 10 8-1/8 7-1/4 3- -7/8 Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077 7

BULLETIN 6- BRONZE SOLENOID VLVES MX. FLUID TEMP. 1 F MX. STTIC PRESSURE Except valves listed for 0 TYPE FULL PORT - NORMLLY CLOSED TO 3 PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve - 303 Stainless Steel *Spring - 30 Stainless Steel *Body Seal - Buna N or Non sbestos Gasket *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) *C Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, 18 leads - (Class H available) To control the flow of Water, Oil, ir, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 1 1-1/4 1- - 3 C 110 184 183 0.4 1. 18 8 7 5-7/8-3-1/4 185 0 E336 45 0.8.4 3 16 8 6-7/8 4-1/8 3-1/4 110 183 1843 0.4 1.3 18 8 7-1/8 6-3- 160 11843 40 0.6.0 8 3333 3353 45 0.8.6 3 1 8-1/8 7 3-3- 0 E13363 65 1. 3.9 33 17 8-1/8 7 4-1/8 3-110 184 1844 0.4 1.5 18 10 7-7/8 6-5/8-4-1/8 160 11844 40 0.6.3 8 3334 3354 45 0.8.8 3 14 8-7/8 7-3- 4-1/8 0 E13364 65 1. 4. 33 19 8-7/8 7-4-1/8 4-1/8 90 18 1845 0.4 1.6 18 1 8-3/8 6- - 4-1 11845 40 0.6.4 8 3335 3355 45 0.8 3.0 3 16 9-3/8 7-3- 4-0 4065 60 1. 6. N/ 0 10-3/8 8-4- 4-115 356 3546 45 0.8 3. 3 0 10 8-1/8 4 4-7/8 160 13546 65 1. 4.8 33 4136 4156 60 1. 6.7 35 4 11 9-1/8 4-4-7/8 0 14166 85.0 10.0 45 100 367 3647 45 0.8 3.5 3 31 11 8-5-3/8 6 1 13647 65 1. 5.0 33 437 457 60 1. 7.4 35 36 1 9-5-3/8 6 0 1467 85.0 11.0 45 438 1 4348 4338 60 1. 8.0 35 43 1-7/8 10-1/8 5-7/8 7-1/4 14358 85.0 1.0 45 449 100 4449 4439 60 1. 8.8 35 56 13-10- 6-5/8 8-3/8 14459 85.0 13.0 45 Dimensions In FOR OPTIONS & CCESSORIES SEE PGES 4 & Voltage (C or ) Temperature (See pages 4 & ) Not available for operation 8 Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077

BULLETIN 6-R BRONZE SOLENOID VLVES TYPE R FULL PORT - NORMLLY OPEN TO 3 PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve - 303 Stainless Steel *Spring - 30 Stainless Steel *Body Seal - Buna N or Non sbestos Gasket *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) *C Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, 18 leads - (Class H available) To control the flow of Water, Oil, ir, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. MX. FLUID TEMP. 1 F MX. STTIC PRESSURE Except valves listed for 0 FOR OPTIONS & CCESSORIES SEE PGES 4 & Voltage (C or ) Temperature (See pages 4 & ) Not available for operation 1 1-1/4 1- - 3 C 110 18R4 18R3 0.5 1.5 18 8 8-1/8 7-3-1/4 18R5 0 E33R6 45 1.0.7 3 16 9-3/8 8-1/4 4-1/8 3-1/4 110 18R3 18R43 0.5 1.6 18 9 8-1/4 7-1/8-3- 33R33 33R53 45 1.0.9 3 13 9-1/4 8-1/8 3-3- 0 E133R63 65 1.5 4.3 33 18 9-8-3/8 4-1/8 3-110 18R4 18R44 0.5 1.8 18 11 9 7- - 4-1/8 33R34 33R54 45 1.0 3.0 3 14 10 8-5/8 3-4-1/8 0 E133R64 65 1.5 4.5 33 19 10-1/4 8-7/8 4-1/8 4-1/8 90 18R 18R45 0.5 1.9 18 13 9-8-1/8-4- 33R35 33R55 45 1.0 3. 3 17 10-9-1/8 3-4- 0 40R65 60 1.7 6. N/ 1 11 9-3/8 4-4- 115 35R6 35R46 45 1.0 3.8 3 1 11-3/8 9-4 4-7/8 41R36 41R56 60 1.7 6.5 35 11-5/8 9-4- 4-7/8 0 141R66 85 3.5 9.7 45 100 36R7 36R47 45 1.0 4. 3 31 1-3/8 10-1/8 5-3/8 6 4R37 4R57 60 1.7 7.3 35 36 1-5/8 10-3/8 5-3/8 6 0 14R67 85 3.5 11.0 45 43R8 1 43R48 43R38 60 1.7 8.0 35 45 13-10- 5-7/8 7-1/4 143R58 85 3.5 13.0 45 44R9 100 44R49 44R39 60 1.7 8.8 35 57 14-3/8 11-1/8 6-5/8 8-3/8 144R59 85 3.5 13.0 45 Dimensions In Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077 9

BULLETIN 6-M BRONZE SOLENOID VLVES MX. FLUID TEMP. 400 F MX. STTIC PRESSURE 1 FOR OPTIONS & CCESSORIES SEE PGES 4 & TYPE M - NORMLLY CLOSED 3/8 TO PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN DIRECT CTING - ORIFICE SIZES 1/8 TO Valve opens when energized and closes when de-energized. In this direct acting valve, when the coil is energized, the stem is lifted from its conical seat by the plunger. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPS conduit conn. *Valve Stem - 303 Stainless Steel *Spring - Inconel *Body Seal - Non sbestos Gasket *Orifice Seal - Metal to Metal *C Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class H, 18 leads To control the flow of Steam, Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-97 F), Liquid rgon (-303 F) and Liquid Nitrogen (-30 F). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. INLET 3/8 10 Valve Port C **Cleaning: Cryogenic valves are degreased and cleaned to keep them free of moisture. Oxygen valves are also black light tested. 3/8 10M1 1/4 10M41 75 3/16 10M51 0.4 1.1 18 6 6-1/4 5- -7/8-5/8 100 5/3 10M81 1 1/8 10M61 3/8 M1 75 100 5/16 1/4 M31 M41 45 0.8.3 3 10 7-1/8 6-3/8 3- -5/8 1 3/16 M51 3/8 10M 1/4 10M4 75 3/16 10M5 0.4 1. 18 6 6-1/4 5- -7/8-100 5/3 10M8 1 1/8 10M6 3/8 M 75 5/16 M3 100 1/4 M4 45 0.8.4 3 10 7-1/8 6-3/8 3- - 1 3/16 M5 35 15 5/16 10M33 10M13 0.4 1.3 18 7 6-5-5/8-7/8-7/8 30 75 5/16 M13 M33 45 0.8.5 3 10 7-3/8 6-3- -7/8 Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077 Dimensions In Voltage (C or ) Temperature (See pages 4 & )

BULLETIN 6-MR BRONZE SOLENOID VLVES TYPE MR - NORMLLY OPEN 3/8 TO PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN DIRECT CTING - ORIFICE SIZES 1/8 TO Valve closes when energized and opens when de-energized. In this direct acting valve, when the coil is energized, the stem is pressed into its conical seat by the plunger. INLET Voltage (C or ) Temperature (See pages 4 & ) 3/8 CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPS conduit conn. * Poppet - 304 Stainless Steel *Stem - 303 Stainless Steel *Spring - Inconel *Body Seal - Non sbestos Gasket *Orifice Seal - Metal to Metal *C Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class H, 18 leads To control the flow of Steam, Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-97 F), Liquid rgon (-303 F) and Liquid Nitrogen (-30 F). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. MX. FLUID TEMP. 400 F MX. STTIC PRESSURE 1 FOR OPTIONS & CCESSORIES SEE PGES 4 & **Cleaning: Cryogenic valves are degreased and cleaned to keep them free of moisture. Oxygen valves are also black light tested. Valve Port 3 3/8 10MR1 45 1/4 10MR41 70 3/16 10MR51 0.5 1.4 18 7 7 6-1/4-7/8-5/8 90 5/3 10MR81 135 1/8 10MR61 45 3/8 MR1 70 90 5/16 1/4 MR31 MR41 45 1.0.6 3 10 7-7/8 7-1/8 3- -5/8 135 3/16 MR51 3 3/8 10MR 45 1/4 10MR4 70 3/16 10MR5 0.5 1.5 18 7 7 6-1/4-7/8-90 5/3 10MR8 135 1/8 10MR6 45 3/8 MR 70 5/16 MR3 90 1/4 MR4 45 1.0.7 3 10 7-7/8 7-1/8 3- - 135 3/16 MR5 3 13 5/16 10MR33 10MR13 0.5 1.6 18 7 7-1/4 6-3/8-7/8-7/8 7 70 5/16 MR13 MR33 45 1.0.8 3 11 8-1/8 7-1/4 3- -7/8 UL Listed Valves - Consult Factory C Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077 11 Dimensions In

BULLETIN 6-S BRONZE SOLENOID VLVES MX. FLUID TEMP. 400 F MX. STTIC PRESSURE TYPE S FULL PORT - NORMLLY CLOSED TO 3 PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve - 303 Stainless Steel *Spring - Inconel *Body Seal - Non sbestos Gasket *Orifice Seal - Glass Filled Teflon *C Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class H, 18 leads FOR OPTIONS & CCESSORIES SEE PGES 4 & TO CONTROL THE FLOW OF STEM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 1 1-1/4 1- - 3 C 90 140 14S 114S4 40 0.4 0.6 1. 1.8 18 8 8 7 5-7/8-7/8 3-1/4 180 19S4 65 1. 3.6 33 11 8 6-7/8 3-3-1/4 110 14S3 114S43 40 0.4 0.6 1.3.0 18 8 9 7-1/8 6-7/8 3-180 19S43 65 1. 3.9 33 1 8-1/8 7 3-3- 16S14 0.4 1.5 18 90 116S4 116S44 40 0.6.3 8 11 8 6-5/8 3-1/4 4-1/8 180 131S44 65 1. 4. 33 14 8-7/8 7-3- 4-1/8 17S15 117S 40 0.4 0.6 1.6.4 18 8 1 8-3/8 6-3- 4-140 13S45 65 1. 4.5 33 16 9-3/8 7-3-5/8 4-180 140S45 85.0 9. N/ 0 10-3/8 8-4- 4-35S16 35S6 45 0.8 3. 3 0 10 8-1/8 4 4-7/8 90 135S46 65 1. 4.8 33 180 141S46 85.0 10.0 45 4 11 9-1/8 4-4-7/8 36S17 36S7 45 0.8 3.5 3 31 11 8-5-3/8 6 115 180 4S47 14S47 60 85 1..0 7.4 11.0 35 45 36 1 9-5-3/8 6 43S18 43S8 115 43S48 60 1. 8.0 35 43 1-7/8 10-1/8 5-7/8 7-1/4 175 143S48 85.0 1.0 45 44S19 100 44S9 44S49 60 1. 8.8 35 56 13-10- 6-5/8 8-3/8 1 144S49 85.0 13.0 45 UL Listed Valves - Consult Factory Not available for operation Dimensions In Voltage (C or ) Temperature (See pages 4 & ) 1 Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077

BULLETIN 6-SR BRONZE SOLENOID VLVES TYPE SR FULL PORT - NORMLLY OPEN TO 3 PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. MX. FLUID TEMP. 400 F MX. STTIC PRESSURE CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Poppet - 303 Stainless Steel *Stem - 303 Stainless Steel *Springs - Inconel and 30 Stainless Steel *Body Seal - Non sbestos Gasket *Orifice Seal - Glass Filled Teflon *C Shading Coil - Copper *Stem Pin - 304 Stainless Steel Coil - Encapsulated Class H, 18 leads TO CONTROL THE FLOW OF STEM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. FOR OPTIONS & CCESSORIES SEE PGES 4 & Voltage (C or ) Temperature (See pages 4 & ) 1 1-1/4 1- - 3 C 90 140 14SR 114SR4 40 0.5 0.8 1.5.4 18 8 8 8-1/8 7-7/8 3-1/4 180 19SR4 65 1.5 4. 33 11 9-1/8 8 3-3-1/4 110 14SR3 114SR43 40 0.5 0.8 1.6.6 18 8 9 8-1/4 7-1/8-7/8 3-180 19SR43 65 1.5 4.3 33 13 9-1/4 8-1/8 3-3- 16SR14 0.5 1.8 18 90 116SR4 116SR44 40 0.8.9 8 11 9-1/8 7-3-1/4 4-1/8 180 131SR44 65 1.5 4.5 33 15 10 8-5/8 3-4-1/8 17SR15 117SR 40 0.5 0.8 1.9 3.0 18 8 13 9-8-1/8 3-4- 140 13SR45 65 1.5 4.8 33 17 10-9-1/8 3-5/8 4-180 140SR45 85 3.5 9.0 N/ 0 11 9-3/8 4-4- 35SR16 35SR6 45 1.0 3.8 3 1 11-3/8 9-4 4-7/8 90 135SR46 65 1.5 5.7 33 180 141SR46 85 3.5 9.7 45 11-5/8 9-4- 4-7/8 36SR17 36SR7 45 1.0 4. 3 31 1-3/8 10-1/8 5-3/8 6 115 180 4SR47 14SR47 60 85 1.7 3.5 7.3 11.0 35 45 36 1-5/8 10-3/8 5-3/8 6 43SR18 43SR8 115 43SR48 60 1.7 8.0 35 45 13-10- 5-7/8 7-1/4 175 143SR48 85 3.5 1.0 45 44SR19 100 44SR9 44SR49 60 1.7 8.8 35 57 14-3/8 11-1/8 6-5/8 8-3/8 1 144SR49 85 3.5 13.0 45 UL Listed Valves - Consult Factory Not available for operation Dimensions In Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077 13

BULLETIN 6-L BRONZE SOLENOID VLVES MX. FLUID TEMP. 400 F MX. STTIC PRESSURE Except valves listed for 0 TYPE L FULL PORT - NORMLLY CLOSED TO 3 PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPT conduit conn. *Pilot Valve - 303 Stainless Steel *Spring - Inconel *Body Seal - Non sbestos Gasket *Orifice Seal - Glass Filled Teflon *C Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class H, 18 leads FOR OPTIONS & CCESSORIES SEE PGES 4 & FOR STEM PPLICTIONS SEE BULLETIN 6-S Page 1 To control the flow of Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-97 F), Liquid rgon (-303 F) and Liquid Nitrogen (-30 F). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 14 1 1-1/4 1- - 3 C 110 14L4 14L3 0.4 1. 18 8 7 5-7/8-7/8 3-1/4 9L5 45 0.8.4 3 11 8 6-7/8 3-3-1/4 0 E9L6 45 0.8.4 3 16 8 6-7/8 4 3-1/4 110 14L3 14L43 0.4 1.3 18 9 7-1/8 6-7/8 3-9L33 19L53 45 65 0.8 1..6 3.9 3 33 1 8-1/8 7 3-3- 0 E19L63 65 1. 3.9 33 17 8-1/8 7 4 3-110 16L4 16L44 0.4 1.5 18 11 8 6-5/8 3-1/4 4-1/8 31L34 131L54 45 65 0.8 1..8 4. 3 33 14 8-7/8 7-3- 4-1/8 0 E131L64 65 1. 4. 33 19 8-7/8 7-4 4-1/8 90 17L 17L45 0.4 1.6 18 1 8-3/8 6-3- 4-3L35 13L55 45 65 0.8 1. 3.0 4.5 3 33 16 9-3/8 7-3-5/8 4-0 140L65 85.0 9. N/ 0 10-3/8 8-4- 4-115 35L6 35L46 45 0.8 3. 3 0 10 8-1/8 4 4-7/8 41L36 60 1. 6.7 35 0 141L56 141L66 85.0 10.0 45 4 11 9-1/8 4-4-7/8 100 36L7 36L47 45 0.8 3.5 3 31 11 8-5-3/8 6 4L37 4L57 60 1. 7.4 35 36 1 9-5-3/8 6 0 14L67 85.0 11.0 45 43L8 1 43L48 43L38 60 1. 8.0 35 43 1-7/8 10-1/8 5-7/8 7-1/4 143L58 85.0 1.0 45 44L9 100 44L49 44L39 60 1. 8.8 35 56 13-10- 6-5/8 8-3/8 144L59 85.0 13.0 45 Not available for operation Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077 Dimensions In ** CLENING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested. Voltage (C or ) Temperature (See pages 4 & )

BULLETIN 6-LR BRONZE SOLENOID VLVES TYPE LR FULL PORT - NORMLLY OPEN TO 3 PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seal it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. MX. FLUID TEMP. 400 F MX. STTIC PRESSURE Except valves listed for 0 ** CLENING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested. Voltage (C or ) Temperature (See pages 4 & ) CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPT conduit conn. *Poppet - 303 Stainless Steel *Stem - 303 Stainless Steel *Springs - Inconel and 30 Stainless Steel *Body Seal - Non sbestos Gasket *Orifice Seal - Glass Filled Teflon *C Shading Coil - Copper *Stem Pin - 304 Stainless Steel Coil - Encapsulated Class H, 18 leads To control the flow of Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-97 F), Liquid rgon (-303 F) and Liquid Nitrogen (-30 F). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 1 1-1/4 1- - 3 C 110 14LR4 14LR3 0.5 1.5 18 8 8-1/8 7-7/8 3-1/4 9LR5 45 1.0.7 3 11 9-1/8 8 3-3-1/4 0 E9LR6 45 1.0.7 3 16 9-1/8 8 4 3-1/4 110 14LR3 14LR43 0.5 1.6 18 9 8-1/4 7-1/8-7/8 3-9LR33 19LR53 45 65 1.0 1.5.9 4.3 3 33 13 9-1/4 8-1/8 3-3- 0 E19LR63 65 1.5 4.3 33 18 9-1/4 8-1/8 4 3-110 16LR4 16LR44 0.5 1.8 18 11 9-1/8 7-3-1/4 4-1/8 31LR34 131LR54 45 65 1.0 1.5 3.0 4.5 3 33 15 10 8-5/8 3-4-1/8 0 E131LR64 65 1.5 4.5 33 0 10 8-5/8 4 4-1/8 90 17LR 17LR45 0.5 1.9 18 13 9-8-1/8 3-4- 3LR35 13LR55 45 65 1.0 1.5 3. 4.8 3 33 17 10-9-1/8 3-5/8 4-0 140LR65 85 3.5 9.0 N/ 0 11 9-3/8 4-4- 115 35LR6 35LR46 45 1.0 3.8 3 1 11-3/8 9-3/8 4 4-7/8 41LR36 60 1.7 6.5 35 0 141LR56 141LR66 85 3.5 9.7 45 11-5/8 9-4- 4-7/8 100 36LR7 36LR47 45 1.0 4. 3 31 1-3/8 10-1/8 5-3/8 6 4LR37 4LR57 60 1.7 7.3 35 36 1-5/8 10-3/8 5-3/8 6 0 14LR67 85 3.5 11.0 45 43LR8 1 43LR48 43LR38 60 1.7 8.0 35 45 13-10- 5-7/8 7-1/4 143LR58 85 3.5 1.0 45 44LR9 100 44LR49 44LR39 60 1.7 8.8 35 57 14-3/8 11-1/8 6-5/8 8-3/8 144LR59 85 3.5 13.0 45 Not available for operation FOR OPTIONS & CCESSORIES SEE PGES 4 & FOR STEM PPLICTIONS SEE BULLETIN 6-SR Page 13 Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077 15 Dimensions In

BULLETIN 6-G BRONZE SOLENOID VLVES MX. FLUID TEMP. 1 F MX. STTIC PRESSURE 1 TYPE G FULL PORT - NORMLLY CLOSED 1 TO 3 PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stem - 303 Stainless Steel *Pilot Valve Disc er - Brass *Pilot Valve Seal - Buna N (Viton available) *Spring - 30 Stainless Steel *Body Seal - Buna N or Non sbestos Gasket *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) *C Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, 18 leads - (Class H available) FOR OPTIONS & CCESSORIES SEE PGES 4 & To control the flow of Water, ir, Gas, Solvents, Vacuum and any other fluids not reactive with construction materials and free of sediment. Buna N seating of the pilot and main orifices make the valves ideal for TIGHT SETING, LOW PRESSURE and LOW FLOW conditions. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 1 1-1/4 1- - 3 C 0 18G4 0.4 1.4 18 9 7-6-1/8-4-1/8 30 118G4 40 0.6.3 8 9 7-6-1/8-4-1/8 133G4 65 1. 4.0 33 13 8-7-1/8 3-4-1/8 0 18G 0.4 1.5 18 10 8 6-3/8-7/8 4-3/8 30 118G 40 0.6.4 8 10 8 6-3/8-7/8 4-3/8 133G 65 1. 4.1 33 14 8-7/8 7-3/8 3-4-3/8 15 18G6 0.4 1.7 18 1 8-1/8 6-3-1/8 4-118G6 40 0.6.5 8 1 8-1/8 6-3-1/8 4-35 133G6 65 1. 4. 33 16 9-1/8 7-3- 4-18 33G7 45 0.8 3.4 3 0 9-7/8 7-7/8 3-5- 30 133G7 65 1. 4. 33 0 9-7/8 7-7/8 3-5- 33G7 80 1.8 9.0 40 0 9-7/8 7-7/8 3-5- 13 37G8 40 0.8 3.6 3 33 11-1/8 8-5/8 5-7/8 7-1/8 43G8 60 1. 7.8 35 38 1-1/8 9-5/8 5-7/8 7-1/8 35 143G8 85.0 1.0 45 38 1-1/8 9-5/8 5-7/8 7-1/8 44G9 60 1. 8.6 35 46 13 10 6-5/8 8 35 144G9 85.0 13.0 45 46 13 10 6-5/8 8 Dimensions In Voltage (C or ) Temperature (See pages 4 & ) UL Listed Valves - Consult Factory 16 Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077

BULLETIN 6-GR BRONZE SOLENOID VLVES TYPE GR FULL PORT - NORMLLY OPEN 1 TO 3 PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. MX. FLUID TEMP. 1 F MX. STTIC PRESSURE 1 CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stem - 303 Stainless Steel *Pilot Valve Disc er - Brass *Pilot Valve Seal - Buna N (Viton available) *Spring - 30 Stainless Steel *Body Seal - Buna N or Non sbestos Gasket *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) *C Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, 18 leads - (Class H available) To control the flow of Water, ir, Gas, Solvents, Vacuum and any other fluids not reactive with construction materials and free of sediment. Buna N seating of the pilot and main orifices make the valves ideal for TIGHT SETING, LOW PRESSURE and LOW FLOW conditions. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. FOR OPTIONS & CCESSORIES SEE PGES 4 & Voltage (C or ) Temperature (See pages 4 & ) 1 1-1/4 1- - 3 C 0 18GR4 0.5 1.5 18 9 8-5/8 7-1/4-4-1/8 35 33GR4 45 1.0 3.0 3 13 9-5/8 8-1/4 3-4-1/8 0 18GR 0.5 1.9 18 10 9-3/8 7- -7/8 4-3/8 35 33GR 45 1.0 3. 3 14 10-1/4 8-3- 4-3/8 15 18GR6 0.5.0 18 1 9-7-7/8 3-1/8 4-33GR6 45 1.0 3.8 3 16 10-8-7/8 3-4- 18 33GR7 45 1.0 4. 3 1 11-1/4 9-1/4 3-5- 30 133GR7 65 1.5 4.5 33 1 11-1/4 9-1/4 3-5- 13 37GR8 45 1.0 4.4 3 34 1-10 5-7/8 7-1/8 43GR8 60 1.7 8.0 35 39 1-10-1/4 5-7/8 7-1/8 44GR9 60 1.7 8.8 35 47 13-5/8 10-5/8 6-5/8 8 UL Listed Valves - Consult Factory Dimensions In Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077 17

BULLETIN 6-D BRONZE SOLENOID VLVES MX. FLUID TEMP. 1 F MX. STTIC PRESSURE 1 TYPE D FULL PORT - NORMLLY CLOSED 3/8 TO PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN Valve opens when energized and closes when de-energized. In this direct acting valve the disc holder assembly is lifted from its seat by the plunger. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Disc er - Brass Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Stem - 303 Stainless Steel *Spring - 30 Stainless Steel *Body Seal - Buna N *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) *C Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, 18 leads - (Class H available) FOR OPTIONS & CCESSORIES SEE PGES 4 & To control the flow of Water, ir, Gas, Solvents, Vacuum and any other fluids not reactive with construction materials and free of sediment. Buna N seating of the main orifice make the valves ideal for TIGHT SETING, LOW PRESSURE and LOW FLOW conditions. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 3/8 1 1-1/4 1- C 15 18D11 0.4 1.0 18 7 6-1/4 5-3/8 - -7/8 30 33D11 45 0.8.3 3 10 7-1/8 6-3/8 3- -7/8 10 18D1 0.4 1.1 18 7 6-1/4 5- - 3-1/8 0 33D1 45 0.8.4 3 10 7-1/4 6-3/8 3-3-1/8 4 18D13 0.4 1. 18 8 6-7/8 5- - 3-7.5 33D13 45 0.8.5 3 1 7-6- 3-3- 18D14 0.4 1.4 18 9 7-6-1/8-4-1/8 3.5 33D14 45 0.8.7 3 13 8-7-1/8 3-4-1/8 1.3 18D15 0.4 1.5 18 10 8 6-3/8-7/8 4-3/8.3 33D15 45 0.8.8 3 14 8-7/8 7-3/8 3-4-3/8 0.8 18D16 0.4 1.7 18 1 8-1/8 6-3-1/8 4-1.5 33D16 45 0.8 3.0 3 15 9-1/8 7-3- 4-0.8 33D17 45 0.8 3.4 3 19 9-7/8 7-7/8 3-5- 1. 133D17 65 1. 4. 33 19 9-7/8 7-7/8 3-5- Dimensions In Voltage (C or ) Temperature (See pages 4 & ) UL Listed Valves - Consult Factory 18 Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077

BULLETIN 6-STN-Y STRINERS Bronze Stainless Steel The presence of foreign particles in an automatic valve may seriously affect its dependability. The installation of a strainer close to the inlet side of the valve is the best means of preventing the entrance of pipe chips, scale, rust, pipe dope, welding slag or sediment into the valve, provided the screen is periodically removed for cleaning. CONSTRUCTION: Strainer bodies have screwed ends. Screens are stainless steel with opening sizes as listed in tables below. Other sizes can be furnished upon request. Liberal straining area provides for fluid passage at minimum pressure drop. Screens are easily removed for cleaning. furnished with NPT blow-off connections unplugged. See charts below for blow-off sizes (C Dim.) CLENING FOR CRYOGENIC & OXYGEN SERVICE: Strainers for Cryogenic applications are degreased and cleaned to keep them free of moisture. Strainers for Oxygen service are degreased and cleaned then black light tested. BRONZE 1/4 TO 3 PIPE SIZE Screen Dimensions In 1/4 ST 0 - -1/4 1/4 3/8 60 Mesh ST 1 - -1/4 1/4 0.009 ST - -1/4 1/4 Openings ST 3 1-3 -9/16 3/8 1 ST 4-1/4 3- - 3/8 1-1/4 ST 5 3-1/4 4-7/16 3-5/8 1-0.16 Diameter ST 6 4-4-15/16 3-7/8 Perforations ST 7 7 6-1/8 5-1/16 1 Lined With - 30 Mesh ST 8 1-8-1/4 6 1-1/4 3 ST 9 18 9 6-1- B C STINLESS STEEL TO PIPE SIZE Screen Dimensions In 60 Mesh ST SS 1-3 -3/8 1/4 0.009 ST 3SS -1/4 3- -13/16 3/8 1 Openings ST 4SS 3-1/4 4-5/8 3-1/8 3/8 1-0.16 Diameter ST 6SS 6-5-5/8 4- Perforations Lined w/30 Mesh ST 7SS 11-7 6 1 B C PRESSURE TEMPERTURE RTINGS MTERIL STEM LIQUIDS BRONZE @ 400 F 600 @ 100 F STINLESS STEEL 845 @ 7 F 1,440 @ 100 F Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077 19

0 MX. FLUID TEMP. 400 F MX. STTIC PRESSURE Except valves listed for 0 FOR OPTIONS & CCESSORIES SEE PGES 4 & 1 1-3 110 14K4 14K3 C BULLETIN 6-K STINLESS STEEL SOLENOID VLVES TYPE K FULL PORT - NORMLLY CLOSED TO 3 PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. CONSTRUCTION: (*Wetted parts - No Copper Bearing lloys in contact with fluid) *Valve Body - 304 Stainless Steel Globe Pattern - NPT ends (For Flanged Ends see Options page 4) *Piston - 303 Stainless Steel Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve - 303 Stainless Steel *Spring - Inconel *Body Seal - Non sbestos Gasket *Orifice Seal - Glass Filled Teflon *C Shading Coil - Silver *Stem Pin - Inconel Coil - Encapsulated Class H, 18 leads To control the flow of Corrosive Fluids, Deionized Water, Condensate, mmonias, Vegetable Oils, Fuel Oils, Cryogenics**, Flammable Liquids. Cryogenic fluids include liquid oxygen (-97ºF), liquid argon (-303ºF) and liquid nitrogen (-30ºF). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. ping Weights above apply to Threaded Ends Only (except 3 which are Flanged Only) For Flanged Ends contact factory for complete weight and dimensions 3 STINLESS STEEL VLVES RE SUPPLIED WITH FLNGED ENDS ONLY Dimensions In FOR STEM PPLICTIONS SEE BULLETIN 6-W Page Voltage (C or ) Temperature (See pages 4 & ) Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077 B C D NPT D (Flanged) 1# # 0.4 1. 18 7 7 5-7/8-7/8 9K5 45 0.8.4 3 10 8 6-7/8 3-0 E9K6 15 4 3-1/4 6 6-110 14K43 0.4 1.3 18 8 7-1/8 6-7/8 9K33 45 0.8.6 3 11 3-3- 6 6-19K53 65 1. 3.9 33 8-1/8 7 0 E19K63 16 4 110 16K44 0.4 1.5 18 10 8 6-5/8 3-1/4 31K34 45 0.8.8 3 13 3-4-1/8 6-7- 8-7/8 7-0 131K54 E131K64 65 1. 4. 33 18 4 115 35K46 45 0.8 3. 3 17 10 8-1/8 4 41K36 60 1. 6.7 35 4-7/8 6-7- 141K56 85.0 10.0 45 1 11 9-1/8 4-0 141K66 100 36K47 45 0.8 3.5 3 7 11 8-4K37 4K57 60 1. 7.4 35 3 1 9-5-3/8 6 8 9 0 14K67 85.0 11.0 45 100 44K49F1 60 1. 8.8 35 68 9- N/ 44K39F1 13-10- 6-5/8 N/ 144K59F3 85.0 13.0 45 81 N/ 1- ** CLENING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested.

BULLETIN 6-KR STINLESS STEEL SOLENOID VLVES TYPE KR FULL PORT - NORMLLY OPEN TO 3 PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. CONSTRUCTION: (*Wetted parts - No Copper Bearing lloys in contact with fluid) *Valve Body - 304 Stainless Steel Globe Pattern - NPT ends (For Flanged Ends see Options page 4) *Piston - 303 Stainless Steel Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Poppet - 303 Stainless Steel *Stem - 303 Stainless Steel *Spring - Inconel *Body Seal - Non sbestos Gasket *Orifice Seal - Glass Filled Teflon *C Shading Coil - Silver *Stem Pin - 304 Stainless Steel Coil - Encapsulated Class H, 18 leads To control the flow of Corrosive Fluids, Deionized Water, Condensate, mmonias, Vegetable Oils, Fuel Oils, Cryogenics**, Flammable Liquids. Cryogenic fluids include liquid oxygen (-97ºF), liquid argon (-303ºF) and liquid nitrogen (-30ºF). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. ** CLENING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested. Voltage (C or ) Temperature (See pages 4 & ) 1 1-3 FOR STEM PPLICTIONS SEE BULLETIN 6-WR Page 3 C MX. FLUID TEMP. 400 F MX. STTIC PRESSURE Except valves listed for 0 FOR OPTIONS & CCESSORIES SEE PGES 4 & 110 14KR4 14KR3 0.5 1.5 18 7 8-1/8 7-7/8 9KR5 45 1.0.7 3 10 9-1/8 8 3-0 E9KR6 15 4 3-1/4 6 6-110 14KR43 0.5 1.6 18 8 8-1/4 7-1/8-7/8 9KR33 45 1.0.9 3 1 3-3- 6 6-19KR53 65 1.5 4.3 33 9-1/4 8-1/8 0 E19KR63 17 4 110 16KR44 0.5 1.8 18 10 9-1/8 7-3-1/4 31KR34 45 1.0 3.0 3 14 3-4-1/8 6-7- 10 8-5/8 0 131KR54 E131KR64 65 1.5 4.5 33 0 4 115 35KR46 45 1.0 3.8 3 18 11-3/8 9-4 41KR36 60 1.7 6.5 35 4-7/8 6-7- 141KR56 85 3.5 9.7 45 11-5/8 9-4- 0 141KR66 100 36KR47 45 1.0 4. 3 7 1-3/8 10-1/8 4KR37 4KR57 60 1.7 7.3 35 3 1-5/8 10-3/8 5-3/8 6 8 9 0 14KR67 85 3.5 11.0 45 100 44KR49F1 60 1.7 8.8 35 69 9- N/ 44KR39F1 14-3/8 11-1/8 6-5/8 N/ 144KR59F3 85 3.5 13.0 45 8 N/ 1- Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077 1 Dimensions In D (Flanged) 1# # ping Weights above apply to Threaded Ends Only (except 3 which are Flanged Only) For Flanged Ends contact factory for complete weight and dimensions 3 STINLESS STEEL VLVES RE SUPPLIED WITH FLNGED ENDS ONLY

BULLETIN 6-W STINLESS STEEL SOLENOID VLVES MX. FLUID TEMP. 400 F MX. STTIC PRESSURE TYPE W FULL PORT - NORMLLY CLOSED TO 3 PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. 1 1-3 FOR OPTIONS & CCESSORIES SEE PGES 4 & C CONSTRUCTION: (*Wetted parts - No Copper Bearing lloys in contact with fluid) *Valve Body - 304 Stainless Steel Globe Pattern - NPT ends (For Flanged Ends see Options page 4) *Piston - 303 Stainless Steel Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve - 303 Stainless Steel *Spring - Inconel *Body Seal - Non sbestos Gasket *Orifice Seal - Glass Filled Teflon *C Shading Coil - Silver *Stem Pin - Inconel Coil - Encapsulated Class H, 18 leads To control the flow of STEM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 90 140 14W 114W4 40 0.4 0.6 1. 1.8 18 8 7 7 5-7/8-7/8 3-1/4 6 180 19W4 65 1. 3.6 33 10 8 6-7/8 3-110 14W3 114W43 40 0.4 0.6 1.3.0 18 8 8 7-1/8 6-7/8 3-6 180 19W43 65 1. 3.9 33 11 8-1/8 7 3-16W14 0.4 1.5 18 90 116W4 116W44 40 0.6.3 8 10 8 6-5/8 3-1/4 180 131W44 65 1. 4. 33 13 8-7/8 7-3- 35W16 35W6 45 0.8 3. 3 17 10 8-1/8 4 90 135W46 65 1. 4.8 33 180 141W46 85.0 10.0 45 1 11 9-1/8 4-36W17 36W7 45 0.8 3.5 3 7 11 8-115 180 4W47 14W47 60 85 1..0 7.4 11.0 35 45 3 1 9-44W19F1 44W9F1 60 1. 8.8 35 100 44W49F1 1 144W49F1 85.0 13.0 45 Dimensions In D (Flanged) 1# 4-1/8 6-4-7/8 6-5-3/8 6 8 68 13-10- 6-5/8 N/ 9- ping Weights above apply to Threaded Ends Only (except 3 which are Flanged Only) For Flanged Ends contact factory for complete weight and dimensions 3 STINLESS STEEL VLVES RE SUPPLIED WITH FLNGED ENDS ONLY Voltage (C or ) Temperature (See pages 4 & ) Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077

BULLETIN 6-WR STINLESS STEEL SOLENOID VLVES TYPE WR FULL PORT - NORMLLY OPEN TO 3 PIPE SIZE NO DIFFERENTIL PRESSURE REQUIRED TO OPEN Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. CONSTRUCTION: (*Wetted parts - No Copper Bearing lloys in contact with fluid) *Valve Body - 304 Stainless Steel Globe Pattern - NPT ends (For Flanged Ends see Options page 4) *Piston - 303 Stainless Steel Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Poppet - 303 Stainless Steel *Stem - 303 Stainless Steel *Spring - Inconel *Body Seal - Non sbestos Gasket *Orifice Seal - Glass Filled Teflon *C Shading Coil - Silver *Stem Pin - 304 Stainless Steel Coil - Encapsulated Class H, 18 leads MX. FLUID TEMP. 400 F MX. STTIC PRESSURE To control the flow of STEM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Voltage (C or ) Temperature (See pages 4 & ) 1 1-3 C FOR OPTIONS & CCESSORIES SEE PGES 4 & 90 140 14WR 114WR4 40 0.5 0.8 1.5.4 18 8 7 8-1/8 7-7/8 3-1/4 6 180 19WR4 65 1.5 4. 33 10 9-1/8 8 3-110 14WR3 114WR43 40 0.5 0.8 1.6.6 18 8 8 8-1/4 7-1/8-7/8 3-6 180 19WR43 65 1.5 4.3 33 1 9-1/4 8-1/8 3-16WR14 0.5 1.8 18 90 116WR4 116WR44 40 0.8.9 8 10 9-1/8 7-3-1/4 180 131WR44 65 1.5 4.5 33 14 10 8-5/8 3-35WR16 35WR6 45 1.0 3.8 3 18 11-3/8 9-4 90 135WR46 65 1.5 5.7 33 180 141WR46 85 3.5 9.7 45 11-5/8 9-4- 36WR17 36WR7 45 1.0 4. 3 7 1-3/8 10-1/8 115 180 4WR47 14WR47 60 85 1.7 3.5 7.3 11.0 35 45 3 1-5/8 10-3/8 44WR19F1 44WR9F1 60 1.7 8.8 35 100 44WR49F1 1 144WR49F1 85 3.5 13.0 45 4-1/8 6-4-7/8 6-5-3/8 6 8 69 14-3/8 11-1/8 6-5/8 N/ 9- Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077 3 Dimensions In D (Flanged) 1# ping Weights above apply to Threaded Ends Only (except 3 which are Flanged Only) For Flanged Ends contact factory for complete weight and dimensions 3 STINLESS STEEL VLVES RE SUPPLIED WITH FLNGED ENDS ONLY

BULLETIN 6-OPT OPTIONL FETURES For Solenoid Valves See Individual Options For vailability For Use With Specific Valve Types BOTTOM MOUNTED OPTIONS Note: Only One Bottom Mount Option Can Be Installed On Each Valve MNUL OVERRIDE (Normally Closed valves only) (Designated by Prefix MO ) Enables manual opening of solenoid valve during power failure or to override automatic controls. DSHPOT (Designated by Prefix DP ) Furnished for clean liquids to reduce water hammer effect sometimes encountered in long pipe runs by slowing valve closing. LEVER (Normally Closed valves only) (Designated by Prefix LV ) Enables rapid opening of solenoid valve. Can be chain operated for use at inaccessible locations. FLOW CONTROL (Normally Closed, NR & MR valves, only) (Designated by Prefix FC ) Provides a manual method of reducing or throttling the flow. MOUNTING STUD (Designated by Prefix MS ) 3/8-16 thread can be furnished in bottom of body to facilitate mounting on bracket. (Not available on, - and 3 ) DRIN (Normally Closed, NR & MR valves, only) (Designated by Prefix DR ) - 1/4 NPT plug supplied in bottom of valve to facilitate draining of liquid from valve body. OTHER OPTIONS PILOT TP (Designated by Prefix PT ) Type D, G & GR Valves can be furnished with 1/8 tapped hole for pilot connection or pressure gauge. DIN CONNECTOR (Designated by Suffix DN ) Provides 3 prong connector for easy power connect / disconnect. Not available for Explosion-Proof. 4 HUM FREE : (No C Hum/Buzz) (Designated by Suffix HF ) - The HUM FREE option eliminates the C hum associated with C operated solenoid valves. Enables valves to be used where an C hum would not be acceptable and C is the only power source available. IE: Hospitals, labs, schools (class rooms), homes, office environments etc. & when 4 vac is required for 40 series valves. Leak / Dead Tight: (Normally Closed valves only) (Designated by Suffix LT ) - The Leak / Dead Tight Option offers soft resilient seating or gapless seal for low pressure applications or less. Consult Factory for Pressure and Valve Type availability. Flanged Ends for SS Valves: (Designated by Suffix F1 for 1 lb or F3 for lb Flanges) vailable on stainless steel valves. (Flanged ends for bronze valves available through our Clark-Cooper Division, see bottom of page 3). Explosion-Proof and Watertight Solenoids: (Designated by Prefix F ) are Explosion-proof and NEM 4, 7C & D, 9E, F & G suitable for use in hazardous locations requiring Class I, Groups C & D & Class II Groups E, F, and G equipment. NEM 4X: (Designated by Prefix F ND Suffix ZP ) are suitable for use in locations requiring a NEM 4X designation. ZP (Zinc Plating) replaces the standard paint used on the Coil housing (cup and base). The additional corrosion protection satisfies NEM 4X requirements. Internal construction, pressure ratings, power consumption, and external dimensions are the same as for standard valves. Nickel Plating: (Designated by Suffix NP ) - Plating is 0.0005 Thick Meets Mil Spec. C6074 Universal Mount Valves For Mounting In Vertical Runs (See Magnatrol Universal Mount Catalog 6-UM) Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077

BULLETIN 6-POS/IND POSITION INDICTORS For Normally Closed Solenoid Valves Position Switches CONSTRUCTION: Housing - 316 Stainless Steel with NPT Conduit Connection Contact - SPDT (Single Pole/Double Throw) Lead Wires - 36 inches long, 18 gauge standard leads potted-in PVC Switch is activated by a ferromagnetic target attached to the valve s piston PS shown with valve body adaptor PS - General Purpose/NEM 4, 4X PSF - Explosion Proof SPDT Contact Electrical Rating: 4 @ 10 VC / 3 @ 4 V @ 40 VC / 1. @ 48 V 0.5 @ 1 V & V The PS and PSF can be wired C or, N/O or N/C, consume no power to operate, and leave no current leakage or voltage drop Position Switches With LED Visual Indication Position Switch on right shown energizing Red LED PL - General Purpose/NEM 4, 4X PLF - Explosion Proof SPDT Contact Electrical Rating: 0. @ 10 VC / 3 @ 4 V (3 @ 10 VC / @ 4 V without the LEDs) The PL and PLF can be wired C or, N/O or N/C mbiant Temperature: -40 F to 1 F (106 C) PS General Purpose & Water Tight (SPDT Switch) shown on 3 Stainless Steel Valve NOTE: ONLY ONE BOTTOM MOUNTED OPTION CN BE INSTLLED ON ECH VLVE For multiple switches and where a switch and a bottom mounted option are required, contact our Clark Cooper Division. (See bottom of Page 3) Position Display - Visual Indication ONLY PD - General Purpose / NEM 4, 4X / Explosion Proof CONSTRUCTION: Housing - Clear High-Strength Polycarbonate Visual indication that valve is Open / Closed When the valve is in the closed position, a ferromagnetic target attached to the valve s piston, lifts a green colored magnet into the adapter hiding it from view. When the valve is energized, (open position), the magnet drops down to a visible position. Position Indicators for Normally Closed Valve Only vailable on Type, S, L, K, W & G Valves HOW TO ORDER: Indicate Option when Ordering: Use the appropriate Prefix: PS, PSF, PL, PLF, or PD Example: PS1844 indicates a Position Switch mounted on a Type 1844 valve. Magnatrol Valve Corporation P.O. Box 17 67 Fifth venue Hawthorne New Jersey 077