Stratomaster Smart Single

MAP-1. Introduction. 1 Features. Manifold Pressure and RPM Indicator. Operating Manual English 1.03

Temperatures can be displayed in degrees Celsius or degrees Fahrenheit from -100ºC to 1200ºC (-148ºF to 2192ºF).

CNV-AT. Introduction. 1 Features. Airtalk serial altitude to parallel Gillham code for mode C transponders. Operating Manual English 1.

ASI-3. Introduction. 1 Features. Airspeed Indicator (ASI) with automatic flight log. Operating Manual English 1.01

ASI-1. Introduction. 1 Features. Airspeed Indicator (ASI) with automatic flight log. Operating Manual English 1.06

The TC-4 is a 2 1/4 sunlight readable 4 channel thermocouple color display instrument.

Blaze TC-6. Introduction. 1 Features. Twelve channel thermocouple (EGT/CHT) indicator. Operating Manual English 1.00

Vega AHRS-1 / MAG-1. Introduction. 1 Features. Artificial Horizon and Magnetic Compass indicator Magnetic Compass Indicator

E-1. Introduction. 1 Features. Universal engine monitor. Operating Manual English 1.00

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02

RV-3. Introduction. 1 Features. Universal engine RPM and rotor RPM indicator. Operating Manual English 1.00

The E-3 can measure up to 4 EGT/CHT channels, a RPM input, a universal temperature sender input and a universal pressure sender input.

AV-1. Introduction. 1 Features. Artificial horizon and advanced magnetic compass indicator. Operating Manual English 1.00

FF-1. Introduction. 1 Features. Fuel management computer for single or dual fuel tanks. Operating Manual English 1.04

EMS-2. Introduction. Features. Engine Management System. Operating Manual English 1.07

FF-3. Introduction. Fuel management computer for single or dual fuel tanks. Operating Manual English 1.02

In addition, the FF-4 can use the actual ground speed from a RS232 NMEA enabled GPS receiver to determine fuel range.

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

Types E2 and D2. Types Q and L. Including products with: Digital Precision Pressure Gauges

Fuel Level FL1. FL1 - User s manual. Rev Revision#2.0, 28/11/2014 For firmware version 1.2

The kit comes with a 100 psi sensor, solenoids and harness.

All information is displayed in an easy to read format on a high resolution wide viewing angle cd/m2 sunlight readable color display.

MGL Avionics AvioGuard. Fault protected, wide input range, isolated, DC to DC converter for avionics applications

RDAC X. Technical installation document

SCHNITZ MOTORSPORTS PNC-202, 2-STAGE PROGRESSIVE NITROUS CONTROLLER USER MANUAL AND INSTALLATION GUIDE NOS PULSE FREQUENCY

HIGH VACUUM GAUGE / CONTROLLER - analogue

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

Piezoresistive single crystal silicon pressure transmitter

Stratomaster Ultra for Rotorcraft

SCHNITZ MOTORSPORTS USER MANUAL AND INSTALLATION GUIDE PRO-MOD BATTERY VOLTS DIAGNOSTICS NOS PULSE FREQUENCY NOS DELAY TIME IN SECONDS

Air Shift Module User Manual

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi

Annunciator Panel. (AP-7H and AP-7V) Operating and Installation Instructions OI

Rotax 912iS HIC/Power Wiring Harness. Part No: CAV11. Option C : Wire-ended EMU/EMS Connections

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

Piezoresistive single crystal silicon pressure transmitter

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

High Pressure Leak Diagnostics System Part No & NA USER MANUAL LEAK DETECTION SERVICE

GLM SERIES CONTROL Users Manual Rev:

Diagnostic Trouble Code (DTC) memory, checking and erasing

MODEL 1100 TURBINE FLOW METER

Time Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments


51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

THE INSIDE STORY OF THE QPV OR MPV:

1900 William Street. Racine, WI (262) Transformer Application Notes

MGL Avionics EFIS G2 and iefis

EMS Installation Instructions

UNIVERSAL, INDEPENDENT DUAL SYSTEM HYDRAULIC TEST STAND

THE INSIDE STORY OF THE QPV OR MPV:

Single crystal silicon digital pressure switch

POWERSPORTS DYNAMOMETER HARDWARE AND SOFTWARE

Diagnostic Trouble Code (DTC) table

Lingenfelter ECSS-001 Ethanol Content Sensor Signal Simulator Installation & Operating Instructions

MSD Boost Control Module PN 7763

ODYR-25-1 & SLX-25-1 rev. A VACUUM/BOOST PRESSURE, TEMP, and EGT GAUGE

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Inspection, Testing, and Maintenance Fire Pumps NFPA 25, Chapter 8 as amended by CCR, Title 19 Page 1 of 8

Classic Instruments. Belera. Installation Manual

DPG-6700 Instruction Sheet The Direct Drive Difference in Digital

Schmidt Mess- und Regeltechnik

Safety-TrimTM. Dual axis servo controller. with 2 speed presets

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

FP-100 Fuel Pressure and Ammeter Indicator Page 1 of 16. All specification subject to change Aerospace Logic Inc.

RDAC X. Technical installation document

P200 P/I Transducer. Installation, Operation, and Maintenance Instructions INTRODUCTION

Proposed Special Condition for limited Icing Clearances Applicable to Large Rotorcraft, CS 29 or equivalent. ISSUE 1

ENGINE MONITORING SYSTEM OPERATOR'S MANUAL. Release: M. MGL Avionics. P O Box 286 Sundowner 2161 South Africa

Contents. Pressure measurement technology Pressure calibrators 18 Exercises 19-20

4 qts 4 qts 6 qts. 10 qts 12.5 qts. 7.2 pints 9 pints. 3.5 pints. 2.2 pints. 2.5 pints 3.13 pints 3.13 pints

ELECTRONIC FUEL INJECTION

Digital Test Pressure Gauge Digi Gauge TX-430 1

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature


Chevy Truck

Sonic Meter. Soni. Operating Manual. Rev. A

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

Seven Features of the Koganei Vacuum Valve


VACUUM MODULATOR COMPOSITION. Layout. EGR valve. Turbocharger actuator. Vacuum pump hose Vacuum pump. Turbocharger vacuum modulator

VIBRATING WIRE SURFACE STRAIN GAUGE. Model SM-5B. Roctest Limited, All rights reserved.

UNIK Pressure Sensing Platform. GE Sensing & Inspection Technologies. Features

All information is displayed in an easy to read format on a high resolution wide viewing angle 4.3 sunlight readable color display.

DPG-6700 Instruction Sheet The Direct Drive Difference in Digital

MITYFLEX PERISTALTIC PUMPS

All information is displayed in an easy to read format on a high resolution wide viewing angle 4.3 sunlight readable color display.

Monosilicon pressure transmitter

Installation guide for the Stratomaster Flight digital aircraft instrument Page 1

AccuSpark. Fitting and Information Guide For. Modules Distributors coils Tools. Modern Ignition for Classic cars

ORDERING INFORMATION # of Ports Pressure Type Device Device Name Options

OWNER S GUIDE REMOTE CAR STARTER ADS-BZ1 ADS-BZ2 ADS-BZ3 ADS-BZ4 CONFORMITY COMPATIBLE WITH:

I - SYSTEM/COMPONENT TESTS

OPERATOR S MANUAL Please read all the information in this booklet before using the unit.

HOLLEY VR2 FUEL PUMPS P/N & Installation Instructions 199R10975

CPi. CoiL PACK IGNiTioN FOR AViATiON. For 4,6 and 8 cylinder 4 stroke applications. Please read the entire manual before beginning installation.

Ford Mustang. Installation Manual

Transcription:

Stratomaster Maxi Single MAP-2 Universal pressure monitor The MAP-2 is a 3.5 instrument which can measure pressures in the range from 0.25 bars (3.6 PSI) to 2.5 bars (36.2 PSI). Pressure can be displayed in units of millibar, bar, PSI, Kg/cm2, inches of Mercury, millimeters of Mercury, kilopascal (KPA) or atmospheres. The pressure display is also available in form of a bargraph with user selectable sensitivity. The MAP-2 is primarily intended as manifold pressure gauge, however, due to the universal nature of this accurate instrument it can be used for many other applications as well. Typical applications: Engine manifold pressure, Turbo boost pressure, Barometer, fuel or oil pressure gauge (with additional isolation kit), pressure reference, airfoil research and testing.

The main display and function buttons Digital pressure display Analog pressure meter Units of measure Setting up the MAP-2 Press the Menu key to enter the menu. You can move forward and backwards in the menu by using the + and keys. To change or select a menu item, move the highlight to the desired item and then press the Select (Enter) key. To end an edit or function, press the Menu key again. To exit the menu and continue normal operation, press the Menu key. Note, all changes you have initiated during your session will only be remembered by the instrument if you exit the menu.. Technical setup functions Calib and ADC : (accessible only if you start up the instrument while pressing both + and - buttons at the same time) Contrast This function allows you to change the display contrast to your liking. You can select values from about 20 to 45. (can vary depending on display type). Backlight This function allows you to switch the display backlight on or off.

Units: Select the units of measure you prefer for your instrument. You can choose from: mb - millbars bar - bars PSI - pounds per square inch KGcm2 - kilograms per square centimeter HG - inches of Mercury mmhg - millimeters of Mercury KPA - kilopascal atm - atmospheres (1013.25mB on a standard day) The highest resolution can be obtained by setting the unit to millibars. Zoom Yes/No Select if you would like the bargraph to display from 0 to 2.5 bars (full range of unit) or if you would like to zoom the display to show pressures from 0.5 bars to 1.5 bars. Filter Select if your want to apply a digital filter to the signal received from the pressure sensor. Off: The value shown is the mean pressure calculated from a total of 2000 samples taken in the last 0.5 seconds. Fast: The value shown is filtered using a digital filter with a fast time constant. The filter is weighted such that new readings have a greater weighting than historical values. Time constant for this filter is approximately 2 seconds. Slow: Similar to the fast filter, this option chooses a slower filter response with a time constant of approximately 4 seconds. Calib This function is for technical personal. It is not used for ordinary operation of the unit. During manufacture of your instrument a calibration value has been entered here that results in optimum accuracy of your instrument. Never change this value unless you have a very accurate reference (accuracy better than 0.1% with a valid and current calibration certificate that has been issued by an accepted standards body. ADC This function is for technical personal. It is not used for ordinary operation of the unit.

Technical specifications: Display temperature range (operational): -20 to +80 degrees C Supply voltage: +8 to +18V. +24/28V with optional pre-regulator. Supply current: 40mA/60mA (backlight off/on) Pressure range: Absolute, 0.25 bars to 2.5 bars. Maximum error over full range: Less than 1% of full scale when operated at calibration temperature. Never exceed pressure: 5 bars. Weight: 90 grams. Warranty: MGL avionics warrants their products for a period of one year from date of purchase against faulty workmanship. Warranty is limited to the replacement of faulty components and includes the cost of labor. Shipping costs are for the account of the purchaser. Note for operation on supplies with inductive loads: Any operation of electronic instrumentation on power supplies that are subject to high voltages caused by operation of inductive loads (starter motors, solenoids, relays) are required to be fitted with suitable protection. All Smart Singles are guaranteed to withstand temporary over voltage up to 40V without additional protection. We recommend that measures are taken to prevent voltage transients in excess of this limit. MGL Avionics recommends the fitment of a fuse in line with a 33V transorb (available from MGL Avionics at low cost) to protect electronic instruments, radios and intercom systems. Only one such arrangement is required for a cluster of instruments. Please note that product warranty excludes damages caused by unprotected, unsuitable or incorrectly wired electrical supplies. This instrument is not certified by the FAA. Fitting of this instrument to certified aircraft is subject to the rules and conditions pertaining to such in your country. Please check with your local aviation authorities if in doubt. This instrument is intended for ultralight, microlight, homebuilt and experimental aircraft. Operation of this instrument is the sole responsibility of the pilot in command (PIC) of the aircraft. This person must be proficient and carry a valid and relevant pilots license. This person has to make him/herself familiar with the operation of this instrument and the effect of any possible failure or malfunction. Under no circumstances does the manufacturer condone usage of this instrument for IFR flights.

Installing the MAP-2 To other instruments RED Fuse BLACK Power switch Positive supply (+12V from battery) Negative supply (airframe ground) Cannon D-9 connector Suggested fuse rating: 1.0 A slow blow Pressure port Connect the supply terminals to your aircrafts power supply (you need a dropping resistor or preregulator for 24/28V systems). Install suitable power supply protection if you have a supply that can contain large voltage transients such as can be created by starter motors and solenoids. Ensure that the supply voltage will not drop below 8V during operation as this may result in incorrect pressure readings. Standard polyester or silicon hosing with an inside diameter of 3-4mm is suitable as pressure hosing. For high pressure applications the hose should be clamped onto the connector to avoid it slipping off due to expansion of the hose. For applications where a pressure leak may prove troublesome, such as a typical engine manifold application, a restrictor valve should be inserted into the hose so that only very little gas leakage will be present in a case of failure or if the instrument is removed with the engine running. For applications where liquid pressure is to be measured, it must be ensured that the liquid is compatible with flouro-silicon. Fuel is NOT compatible. If in doubt, install an isolation kit. A suitable liquid that can be used to transfer the pressure is ordinary antifreeze as used in cars. Pressure sensor damage as a result of applying aggressive or otherwise incompatible gas or liquid to the internals of the pressure sensor are expressly excluded from warranty.