Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Similar documents
Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

CAV controllers Type RN

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Parts and characteristics

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

CONSTANTFLOW Volume Flow Controllers

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Type VSD35. Nominal length up to 1500 mm: one spigot

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN.

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Ceiling swirl diffusers with perforated face plate

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

Volume Flow Limiters Type VFL

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Slot diffusers for ceiling installation

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

VARYCONTROL VAV Dual Duct Terminal Boxes

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Ceiling swirl diffusers with perforated face plate

Multileaf damper with actuator

Technical documentation

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Ceiling swirl diffusers

Ceiling swirl diffusers

Pressure relief dampers

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

For installation into ductwork

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

VAV Terminal Units SDS

Mechanical mixing box MBM

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Fan - Powered Terminal Unit Series Flow

CAV-S Mechanical constant volume fl ow controller, steel

Ventilation grilles for installation into walls, sills or rectangular

Home > Products > Filter elements and filter units > Particulate filter air terminal devices > Pharmaceutical clean room terminal filters > Type TFP

Ventilation grilles for installation into walls, sills or rectangular

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Ceiling swirl diffusers

VAV TERMINAL BOXES TYPE: BA BT

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION

Marine Fire and Gas Dampers

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

Technical information

Ducted HEPA filter units for highly sensitive areas

VAV terminal units VARYCONTROL. Installation and commissioning manual. GB/en. LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK

TYPE EK-EU SMOKE CONTROL DAMPER

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

Waterside Fancoil Units

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

Type Pneumatic actuators

Fan coil unit NBS 100/150

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

Transcription:

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate can be set using an external scale, no tools required High control accuracy No on-site test measurements required for commissioning Suitable for airflow velocities of up to 12 m/s Any installation orientation; maintenance-free Casing air leakage to EN 1751, class C Optional equipment and accessories Acoustic cladding for the reduction of case-radiated noise Secondary silencer Type CA, CS or CF for the reduction of air-regenerated noise Hot water heat exchanger Type WL and electric air heater Type EL for reheating the airflow Actuator for switching between setpoint values

Application Circular CONSTANTFLOW CAV controllers of Type RN for the precise supply air or extract air flow control in constant air volume systems Mechanical self-powered volume flow control without external power supply Simplified project handling with orders based on nominal size Volume flow rate setpoint can be set on external scale Switching between V and V using optional actuator min max Special features Volume flow rate can be set using an external scale; no tools required High volume flow rate control accuracy Any installation orientation Nominal sizes RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400 Variants RN-S: Compact-height volume flow controller RN: Volume flow controller RN-D: Volume flow controller with acoustic cladding RN-FL: Volume flow controller with flanges on both ends RN-D-FL: Volume flow controller with acoustic cladding and flanges on both ends Units with acoustic cladding and/or a secondary silencer Type CA, CS or CF for demanding acoustic requirements Acoustic cladding cannot be retrofitted Construction Galvanised sheet steel P1: Powder-coated, silver grey (RAL 7001) A2: Stainless steel Parts and characteristics Ready-to-commission controller Damper blade with low-friction bearings Bellows that acts as an oscillation damper Cam plate with leaf spring Scale with pointer to set the volume flow rate setpoint Aerodynamic function testing of each unit on a special test rig prior to shipping Correct operation even under unfavourable upstream conditions (1.5 D straight section required upstream) Attachments

Min/Max actuators: Actuators for switching between minimum and maximum volume flow rate setpoint values Modulating actuators: Actuators for the stepless adjustment of volume flow rates or to switch between minimum and maximum volume flow rate setpoint values Retrofit kits: Actuators and installation accessories Variant RN-S cannot be combined with an actuator Accessories Lip seals on both ends (factory fitted) Matching flanges for both ends Useful additions Secondary silencer Type CA, CS or CF Heat exchanger Type WL Electric air heater Type EL Construction features Circular casing Spigot suitable for circular ducts to EN 1506 or EN 13180 Spigot with groove for lip seal (RN-P1/80 and RN-A2/80 without groove) RN-FL: Circular flanges to EN 12220 Materials and surfaces Galvanised sheet steel construction Casing made of galvanised sheet steel Interior parts, nominal sizes 80 125: stainless steel 1.4301, nominal sizes 160 400: galvanised sheet steel Polyurethane bellows Plain bearings with PTFE coating Leaf spring made of stainless steel Powder-coated construction (P1) Casing made of galvanised sheet steel, powder-coated Interior parts, nominal sizes 80 125: stainless steel 1.4301, nominal sizes 160 400: galvanised sheet steel, powder-coated Stainless steel construction (A2) Casing made of stainless steel 1.4301 Interior parts made of stainless steel Variant with acoustic cladding (-D) Acoustic cladding made of galvanised sheet steel

Rubber profile for the insulation of structure-borne noise Lining is mineral wool Mineral wool To EN 13501, fire rating class A1, non-combustible RAL quality mark RAL-GZ 388 Biosoluble and hence hygienically safe according to the German TRGS 905 (Technical Rules for Hazardous Substances) and EU directive 97/69/EC Standards and guidelines Hygiene conforms to VDI 6022 Casing air leakage to EN 1751, class C Maintenance Maintenance-free as construction and materials are not subject to wear TECHNICAL INFORMATION Function, Technical data, Quick sizing, Specification text, Order code, Produktbeziehungen Variants, Attachments, Dimensions and weight Installation details, Basic information and nomenclature