ES150 - se ries. 150 watts DC POWER SUP PLIES. ES V 0-10 A ES V 0-5 A ES V 0-2 A ES V ma

Similar documents
796+<*; 4(5<(3 ES ,3;(

SX - se ries 150 SX 75-75

796+<*; 4(5<(3 240 S 24 +,3;(

S 280 S 6-40 S S 28-10

SM6000-se ries SM SM SM SM SM SM SM SM

SM3000-se ries SM D SM D SM D SM D SM D SM D

SM se ries SM SM SM 70 - AR - 24 SM AR - 4

796+<*; 4(5<(3 600 S 24 +,3;(

SM3300-se ries. Firm ware Up date SM SM 66-AR-110 SM 100-AR-75 SM 330-AR-22 SM 660-AR-11

Targeted en gi ne e ring de sign. Hedge and Grasscutter mowers

YCAS AIR-COOLED LIQUID CHILLERS YCAS0373 THROUGH YCAS0653 STYLE G (R22) (50 Hz)

Pre-installation Manual. PlateWriter 3600 Pro

MODELS CA-1 & CA-2 MODEL CA-1 CA-TB TECHNICAL BULLETIN BACK PRESSURE / RELIEF REGULATOR FEATURES APPLICATIONS CAUTION

Visible Break Load break switches can in cor po rate a visible break of all three phases.

OBSOLETE DESIGN DATA PREACTION FOAM/WATER SYSTEM USING AFFF OR ARC. March 1, Foam 30a

TECHNICAL DATA OBSOLETE

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Ventilated Distribution Transformers

SM15K - In ter faces. Firm ware Up date INT MOD M/S-2 INT MOD CON INT MOD SER INT MOD DIG INT MOD ANA INT MOD SIM-2

AviStart 2501 Owner's Manual

S4 N 250 B W - 2 xxx. Isomax MCCBs. Isomax Molded case circuit breakers S1 S8

CombiTemp Temperature Measuring System

Visible Break Load break switches can in cor po rate a visible break of all three phases.

NEW CONCEPT OF ELECTRICAL DRIVES FOR PAPER AND BOARD MACHINES BASED ON ENERGY EFFICIENCY PRINCIPLES

HOLOPHANE Outdoor Lighting

DESCRIPTION. The MDrive23 uses a NEMA 23 frame size 1.8 high torque stepping

ENERGY AUDIT AND CONSERVATION POTENTIAL ANALYSIS OF A LARGE COMPREHENSIVE COMMERCIAL BUILDING

Open Frame Power Supplies

STAND ALONE ERV M-SERIES

Low Voltage Network Quality Power factor correction Harmonic fl ickering Dynamic fl icker compensation

S4 N 250 B W - 2 xxx. Isomax. Isomax Molded case circuit breakers S3 S8. MCCBs

STAND ALONE ERV O-SERIES

Non-Ventilated Automation Transformers 6

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION

BENEFITS AND CHALLENGES OF VARIABLE COMPRESSION RATIO AT DIESEL ENGINES

Industrial Power Supplies

Load (2) Single or Dual

Pressure controls, differential pressure controls Type RT REFRIGERATION AND AIR CONDITIONING. Technical leaflet

MODELS 1171 AND 2171

MODEL 2171 CAUTION TECHNICAL BULLETIN BACK PRESSURE / RELIEF REGULATOR FEATURES APPLICATIONS. ISO Registered Company

Switching Power Supplies

CONVERSION OF DIESEL ENGINE INTO SPARK IGNITION ENGINE TO WORK WITH CNG AND LPG FUELS FOR MEETING NEW EMISSION NORMS

! NEVER attempt to remote start the engine while the vehicle is in an enclosed area without sufficient ventilation.

TC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0

BY SPORTS TUTOR OWNER S MANUAL

Low Profile DC Power Supply with Zero Voltage Soft Switching

Section 7 FIBERLIGN Hardware Accessories for OPGW and/or ADSS

Efficiency Model dependant 86 ~ 88% Isolation. Isolation Cap. Switching Freq. Safety. Case Material Base Material Potting.

STAND ALONE ERV S-SERIES

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

ENERGY RECOVERY WHEEL

MODEL PRESSURE REDUCING REGULATOR BODY SIZES 1/4" OR 3/8" (DN8 or DN10) TECHNICAL BULLETIN 3381-TB FEATURES APPLICATIONS

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Visible Break Load break switches can in cor po rate a visible break of all three phases.

Owner s Manual SET-UP OPERATION MAINTENANCE. IMPORTANT: Read Safety Rules and Instructions Carefully OG-4905 PRINTED IN CANADA

HAZARDOUS LOCATION SUBMERSIBLE PUMP Model S4NVX (Class I, Division 1, Group C & D): FM

YCAL0014E_ - YCAL0124E_ R-22 & HFC-407C STYLE C (60 Hz)

KEPCO Will Point You In The Right Direction!

COMBUSTION CHARACTERISTICS OF DIESEL ENGINE OPERATING ON JATROPHA OIL METHYL ESTER

INSTALLATION INSTRUCTIONS FOR ROOFTOP STAND ALONE ENERGY RECOVERY UNIT IN SIDE BY SIDE DESIGN

Electrical Data Application Engineering

INSTALLATION INSTRUCTIONS FOR ROOFTOP STAND ALONE ENERGY RECOVERY UNIT IN VERTICAL (UP/DOWN) AIRFLOW DESIGN

COYOTE. Retrofit Closure. Refinement of the Breed. COYOTE Retrofit Closure. The ideal Closure for replacement or expansion 1-29

PERFORMANCE, EMISSION, AND COMBUSTION CHARACTERISTICS OF A CI ENGINE USING LIQUID PETROLEUM GAS AND NEEM OIL IN DUAL FUEL MODE

Z+ Series. 200W, 400W, 600W and 800W Programmable DC Power Supplies. Z+ Series 1. Model Selector. Minimises system rack height

3-D CFD ANALYSIS ON EFFECT OF HUB-TO-TIP RATIO ON PERFORMANCE OF IMPULSE TURBINE FOR WAVE ENERGY CONVERSION

DEVELOPMENT OF DIELECTRIC SENSOR TO MONITOR THE ENGINE LUBRICATING OIL DEGRADATION

REPAIR MANUAL 71 SERIES SUBMERSIBLE GRINDER UNITS

Section 5 FIBERLIGN Hardware for OPGW

INSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM) MODEL HP-1+6+S HIGH PRESSURE DIFFERENTIAL REDUCING REG U LA TOR SECTION I SECTION II

G2HX Explosion-Proof Submersible Grinder Pumps

SUBMERSIBLE SEWAGE PUMP RECESSED IMPELLER

S3HVX Explosion-Proof Submersible Pump

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW)

Polyshot Heated Sprue Bushings

HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP

MODEL 1000HP-5 and MODEL 1000HP-36

True RMS Ampstik Slip-on Ammeters

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM30-E)

Note1: Efficiency is tested by nominal Vin, full load and at 25 C. Package (3) CTRL Logic (2)

COMBUSTION OF LIQUID FUELS FLOATING ON WATER

STANDARD / GENERAL SPECIFICATIONS

OWNER S MANUAL. ZOELLER HAZARDOUS ENVIRONMENT PUMPS (For Class 1, Division 1, Groups C & D Applications) Explosion Proof Motors

ENERGY EFFICIENCY AND THE GROSS DOMESTIC PRODUCT

Nuclear Safety-Related and N-Stamp Butterfly Valves

The 3 kw Models will accept 200*/230 VAC single phase and 200*/208 VAC three phase input power.

MODEL 964. PNEUMATIC CONTROL VALVE 1/2" - 2" Size w/c27 or C53 Actuator TECHNICAL BULLETIN 964-TB FEATURES APPLICATIONS. ISO Registered Company

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Features. Description. Table of Contents

Features. Regulated Converters. RP20-F 20 Watt 2 x 1 Single & Dual Output. RP20- _F/ Package 4) Control Logic (3) DC/DC Converter

DESCRIPTION SINGLE PACKAGE CONVERTIBLE SERIES HEAT PUMPS FEATURES

MODELS 988 and 989 GLOBE-STYLE PNEUMATIC CONTROL VALVE BODY SECTION II II. REFERENCE SECTION I I. DESCRIPTION AND SCOPE IOM-988/

INSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM) MODEL B7 BACK PRESSURE REGULATOR. SECTION l

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

Unit/Comments. %; Equal Output Loads %; Equal Output Loads Full Load

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 91% Six-Sided Continuous Shield Available as Power Module (RPM60-G)

GB60S 60W Single Output General Purpose Series

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

Transcription:

P.O. BOX 27 4300 AA ZIERIKZEE NETH ER LANDS TEL. +31 111 413656 FAX +31 111 416919 www.deltapowersupplies.com ES150 - se ries 150 watts DC POWER SUP PLIES ES 015-10 0-15 V 0-10 A ES 030-5 0-30 V 0-5 A ES 075-2 0-75 V 0-2 A ES 0300-0.45 0-300 V 0-450 ma 4 mm Safety Sockets Weight only 1.7 kg Wide in put volt age range: 90-265 VAC, 48-62 Hz Ac tive Power Fac tor Cor rec tion Efficiency up to 84 % an alog pro grammable (on both volt age and cur rent) Iso lated an a log pro gram ming with op tional ex ter - nal ISO AMP MOD ULE to pre vent earth loops Pro gramming In puts and Mon i toring Out puts have a very low off set Ethernet or RS232 pro gramming with op tional in ter nal cards IEEE488 pro gram ming with op tional ex ter nal in ter face PSC-488 Very low out put rip ple Stable out put volt age or cur rent In put / out put in su la tion 3750 V rms EMC: high im munity and low emis sion Designed for long life at full power Protected against all over load and short cir cuit con di tions Voltage and cur rent con trol with 10 turn po ten ti om eters, res o lu tion 0.03 % Optional rear panel out put con nection (op tion in cludes re mote sens ing) 48 hours burn-in

DELTA ELEKTRONIKA BV ES150 Out put volt age cur rent 0-15 V 0-10 A 0-30 V 0-5 A 0-75 V 0-2 A 0-300 V 0-450 ma In put AC DC single phase, 48-62 Hz Input cur rent @ 230 VAC power fac tor, 110 / 230 VAC full load in ter nal fuses 90-265 V 1 A 0.99 / 0.83 con tact fac tory 4 AT standby in put power (Vo=Io=0) standby in put power (Vo=Vmax) 6 W 11 W Ef fi ciency AC 230 V in put, full load AC 110 V in put, full load 83 % 80 % 84 % 82 % 84 % 81 % 84 % 81 % Reg u la tion Load 0-100% in ter nal sens ing op tional ex ter nal sens ing 15 mv 2 mv 6 mv 2 mv 5 mv 5 mv 10 mv 10 mv Line 90-265 V AC 0.2 mv 0.5 mv 1 mv 3 mv Load 0-100% CC Line 90-265 V AC CC (in ter nal volt age sens ing) 3 ma 1 ma 0.2 ma 0.1 ma 0.3 ma 0.05 ma Ripple + noise (full load) rms (BW=300 khz) p-p (BW=50 MHz) rms (BW=300 khz) CC p-p (BW=50 MHz) CC 0.5 mv 8 mv 1.5 ma 10 ma 0.6 mv 10 mv 2 ma 1 mv 15 mv 0.1 ma 7 mv (typ i cal 30 mv) 0.03 ma 0.2 ma Temp. coeff., per C CC 5.10-5 Sta bil ity af ter 1 hr warm-up dur ing 8 hrs CC tamb = 25 ± 1 C, Vin = 230 VAC (in ternal volt age sens ing for CC-stab.) 12.10-5 An a log Pro gram ming CC Pro gram ming in puts in put range ac cu racy off set temp. coeff. off set in put im ped ance Mon i tor ing out put out put range ac cu racy off set temp. coeff. off set out put im ped ance ± 0.2% 0 + 3 mv (on 5 V) 10 μv / C 1 MOhm ± 0.2% 1 + 1 mv (on 5 V) 10 μv / C 2 Ohm / max. 4 ma ± 0.8% 0 + 10 mv (on 5 V) 60 μv / C 1 MOhm ± 0.8% 10 0 mv (on 5 V) 60 μv / C 2 Ohm / max. 4 ma Ref er ence volt age on prog. con nec tor TC Vref 5.137 ± 10 mv (Ro = 2 Ohm, max. 4 ma) 50 ppm Page 1-2 SPECIFICATIONS 2001, rev. November 2007

ES150 DELTA ELEKTRONIKA BV +12 V out put Vo on prog. Con nec tor Ro 12 V ± 0.5 V 100 Ohm Sta tus out put CC - sta tus CC - op eration 5 V / 5 ma = logic 1 Re mote shut down In di ca tors (front panel) with + 5 V, 1 ma or re lay con tact -mode, CC-mode Con trols (front panel) Mains on/off, - and CC-potmeter Pro gram ming speed (re sis tive load) Rise time (10-90%) out put volt age step time, (100% load) time, (10% load) 0 15 V 7 ms 3 ms 0 30 V 15 ms 6 ms 0 75 V 17 ms 7 ms 0 300 V 10 ms 4 ms Fall time (90-10%) out put volt age step time, (100% load) time, (10% load) 15 0 V 7 ms 70 ms 30 0 V 15 ms 150 ms 75 0 V 17 ms 160 ms 300 0 V 10 ms 100 ms Re cov ery time re cov ery within di/dt of load step time, @ 50-100% load step max. de vi a tion @ 230 VAC in put voltage 250 ma/μs 100 μs 160 mv 125 ma/μs 100 μs 160 mv 70 ma/μs 100 μs 1 200 mv 6 ma/μs 130 μs 700 mv Out put im ped ance, 0-100 khz < 100 mohm < 200 mohm < 250 mohm < 5 Ohm Pul sat ing load max. tol er a ble AC com po nent of load cur rent f > 1 khz f < 1 khz 10 A peak 5 A peak 2 A peak 0.45 A peak In su la tion input / output creepage / clear ance input / case output / case 3750 Vrms (1 min.) 8 mm 2500 Vrms 600 V DC Safety EN 60950 / EN 61010 EMC Power Sup ply Stan dard EN 61204-3, Emis sion: res i den tial, light in dus trial en vi ron ment (CISPR22-Class B) Im mu nity: in dus trial en vi ron ment Ge neric Emis sion Ge neric Im mu nity EN 61000-6-3, res i den tial, light in dus trial en vi ron ment (EN 55022 B) EN 61000-6-2, in dus trial en vi ron ment Op er at ing Tem per a ture at full load 20 to + 50 C de rate output to 75% at 60 C Hu mid ity max. 95% RH, non con densing, up to 40 C max. 75% RH, non con densing, up to 50 C Stor age tem per a ture 40 to + 85 C Ther mal pro tec tion MTBF Output shuts down in case of in sufficient cooling 500 000 hrs 2001, rev. November 2007 SPECIFICATIONS Page 1-3

DELTA ELEKTRONIKA BV ES150 Hold-Up time (230 VAC in put) Vout = 100%, Iout = 100% Vout = 85%, Iout = 100% Vout = 100%, Iout = 50% Turn on de lay (230 VAC in put) after mains switch on In rush cur rent 25 ms 40 ms 60 ms 250 ms 10 A with NTC re sistor 30 Ohms cold resistance Se ries op er a tion max. total voltage Mas ter / Slave op er a tion Par al lel op er a tion max. total cur rent Mas ter / Slave op er a tion 600 V with op tional ex ter nal Mas ter / Slave Adapter no limit max. 4 units Re mote sens ing (op tional) op tion P119 op tion P120 op tion P121 op tion P122 max. voltage drop per load lead 2 V Note: voltage drop across load leads will subtract from max. available out put voltage Over Volt age Limit (fixed) max. 18 V max. 40 V max. 90 V max. 330 V Po ten ti om eters front panel con trol with knobs res o lu tion screw driver ad just ment at front panel stan dard 0.03% op tion P001 Me ters scale volt age scale cur rent ac cu racy V-me ter ac cu racy A-me ter 0-15.00 V 0-10.00 A 0-30.0 V 0-5.00 A 0-75.0 V 0-2.00 A 0-300 V 0-450 ma In put Con nec tor Euro-connector at rear panel 10 Amp / 65 C IEC320/C14, EN60320/C14 Out put Ter mi nals Stan dard: 4 mm safety sockets at front-panel Pro gram ming con nec tor Cool ing En clo sure de gree of pro tec tion Di men sions (h x w x d) Weight Op tion: screw ter mi nals (0.2-4 mm 2 ) at rear-panel (sockets at front re moved) only com bined with re mote sensing, see re mote sensing for op tion num bers (P119-122) 15 pole D-con nector at rear panel (FE MALE) Con vec tion cool ing IP20 52 x 222 x 202 mm 1.7 kg = Con stant Voltage CC = Con stant Current OVL = Over Voltage Limit Spec i fi ca tions mea sured at t amb = 25 ± 5 C and Vin = 230 VAC, 50 Hz un less oth erwise noted. Connections pro gram ming con nec tor Di men sions Page 1-4 SPECIFICATIONS 2001, rev. November 2007

ES150 DELTA ELEKTRONIKA BV Screw driver ad just ment OP TION P001 For a fixed set ting of the output val ues, avoids ac cidental ad justing of the and CC set tings. The potmeters are moved back wards just be hind the frontpanel and plas tic caps are in serted to cover the holes, see pic ture. Mas ter / Slave op er a tion Parallel and Se ries op eration with equal Cur rent and Voltage shar ing. This way two or more ES-units can be used to gether as one high power unit. Voltage and cur rent of the units is con trolled by the mas ter (by po tentiometers or by pro gramming). For Par allel op eration use 15 pole shielded ca bles, no spe cial op tion re quired. For Se ries op er a tion use the Master / Slave Series Adapter to gether with 15 pole shielded ca bles (1:1). In creased max. out put volt age/cur rent Enforced secondary isolation 1000 V OP TION P069 The max imum out put volt age or cur rent can be in creased by ap proximately 10%. Normally this results in a de rating of the maximum am bient tem perature or other pa ram e ters. Always add in creased value for volt age or cur rent in ordercode, for ex am ple ES 030-5 P069 out put 32V. For ex act de tails con sult the tech nical de partment, email 'Sup port@delta-elektronika.nl'. OP TION P089 The sec ondary iso lation be tween out put and ground is in creased from standard 600 V to 1000 V. Remote sensing / Rear power outlet OP TION P119-122 The volt age across the load is con stant re gardless of the out put cur rent. Rear con nections for power leads. Maximum 2 V per load lead can be com pensated. The sense leads are pro tected against ac cidental interruption. Ex ter nal ISO AMP for iso lated an a log pro gram ming Pro vides gal vanic iso la tion when pro gram ming and mon i tor ing. Prevents prob lems with earth loops and com mon mode volt ages. Pin com patible with the pro gramming con nector on the rear side. Bench op eration and rail mounting. ISO AMP MODULE In ter nal Ethernet Power Sup ply Con trol ler OPTION P150 Internal Ethernet com patible interface to pro gram a unit by a com puter. Com bi na tion pos si ble with P119 - P122 (rear out put ter minals). Note: built in side the ES150, the dig ital user in- and out puts of the PSC-ETH are not avail able. Use the ex ternal mod ule PSC-ETH mod ule in stead. In ter nal RS232 Power Sup ply Con troller OPTION P148 In ter nal RS232 com patible interface to pro gram a unit by a com puter. Com bi na tion pos si ble with P119 - P122 (rear out put ter minals). Ex ter nal IEEE488 Power Sup ply Con troller PSC-488 Ex ter nal IEEE488 com patible interface to pro gram a unit by a com puter. Pin com patible with the pro gramming con nector on the rear side. Bench op eration and rail mounting. Note: it is not pos sible to have a combination of multiple in ternal and/or ex ternal in terfaces. 2001, rev. November 2007 SPECIFICATIONS Page 1-5

DELTA ELEKTRONIKA BV ES150 19" rack mount ing Panel RA 19-1ES for one ES Panel RA 19-2ES for two ES Panel RA 19-ES-PSC for one ES and one PSC-488 module Rear Con nec tions Stan dard unit: An a log pro gram ming Linecord supplied In put Con nec tor An alog pro gramming Op tion P150: Ethernet pro gram ming Ethernet pro gramming Com bi na tion pos si ble with option P119-122 Op tion P148: RS232 pro gram ming RS232 pro gram ming Com bi na tion pos si ble with option P119-122 Op tion P119-122: Rear power out let / rem. sens ing Rear power out / Re mote sensing An alog pro gramming Page 1-6 SPECIFICATIONS 2001, rev. November 2007