Easy and safe installation

Similar documents
110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

FL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Linear fittings EVDL LED fitting - zones 21, & 22

Linear fittings EVNL LED fitting - zones 2, & 22

7 Lighting Technology

Linear fittings EVN Fluorescent fitting - zones 2 & 22

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Linear fittings Fluorescent fitting EVN - Zones 2 & 22

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

7 Lighting Technology

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Linear fittings EVT Weatherproof fluorescent fitting - Industrial applications

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

EXEL-L. Detail of the internal side. Transparent polycarbonate

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Linear Luminaire with LED Series EXLUX 6402/2

Emergency Light Fitting for Fluorescent Lamps Series 6009

7 Lighting Technology

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

PROTECTA III. Construction Tough glass reinforced polyester body

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear luminaire with LED Series EXLUX 6002

LED Linear Luminaire Series EXLUX 6402

Emergency Luminaire with LED Series EXLUX 6409/1

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire with LED Series EXLUX 6002

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

Protected

Panelboards & Motor Starters

Linear fittings EVD Fluorescent fitting - zones 21 & 22

explosive environments Lighting

Linear fittings EVT Weatherproof fluorescent fitting - Industrial applications

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

7 Lighting Technology

Floodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2

10 Load and Motor Switchgear

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

EX-REPAIR AND MAINTENANCE RECEPTACLES

ATX PRE Series 125 Amp Plugs and Sockets Increased Safety

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Sheet Steel Emergency Light Fitting Series 6018

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

FHL. Ex d. Body in aluminium

Protecta III GRP ATEX

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

DE 02 Ceiling Luminaire, recessed

HAZ AREA LIGHTING. Product Brochure. Design to Manufacture FOR HAZARDOUS AREAS. Engineering Solutions. An A-Belco Group Company

7 Lighting Technology

PRE Series 63 Amp Plugs and Sockets Increased Safety

Start Waterproof LED START WATERPROOF LED 1265MM TWIN 4000K PRODUCT OVERVIEW

EWE. Ex de. Cooling fins

Floodlight LED Series 6525

Floodlight LED Series 6125

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Sheet-Steel Light Fittings Series 6114

Floodlight LED Series 6525

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Plugs & Sockets PRE Series: 16 A Plugs and Sockets Increased Safety

Making Hazardous Environments Work

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

PRE Series 125 Amp Plugs and Sockets Increased Safety

Operating Instructions

EX-RECESSED CEILING LIGHT FITTINGS

Industrial luminaires

Transcription:

ATX LUMINAIRES 7 Easy and safe installation 1 2 3 Safety Plus : 1- Mounting can be completed with one hand 2- One handed opening using standard tool 3- Reflector swivels easy access 4- Terminal shield cover opens 5- Easy wiring 4 5

8 INCREASED SAFETY EEx e BI-PIN FLUORESCENT LUMINAIRES ATX: Safety Plus every day The whole ATX EEx e bi-pin fluorescent range offers 8 advantages in terms of installation, maintenance, and servicing in hazardous areas. 6 3 1 2 8 7 4 5 1 Positive safety switch enabling lamps to be changed with main power switched on 2 Quick connector for easy replacement of ballast ensuring wiring safety 3 IP 2X terminal shield enabling ballast to be worked on with main power present 4 Lampholders with locating device for easy tube fitting 5 Replaceable IP 66/67 weatherproof elastomer seal for easy maintenance 6 Threaded cable entries : robust construction and direct screwing of the cable gland New: 3 tube solutions 7 Mechanism prevents energizing the luminaire while cover is open ensurng safe operation The use of 3 tube versions provides increased light intensity, thus reducing the number of units required. Units are available on request with alternate use of the tubes providing greater flexibility of use and quicker installation, while reducing the number of boxes + cables... all thanks to the 3 tube solution with dimmer control. 3 tube switch dimmer control on request 8 Central opening using size 10 Allen key or 6 mm flat screwdriver for easy access 3 tubes lit, standard version without dimmer Central tube lit 2 tubes lit 3 tubes lit

Increased safety lighting 9 CONTENTS Equipment for zones 1 and 2 and 21 and 22 Increased safety bi-pin fluorescent luminaires 8-110/127 V - 220/240 V non-armoured cable 10-110/127 V - 220/240 V armoured cable 12-110/127 V - 220/240 V single phase loop in loop out through wiring 14-254 V armoured and non-armoured cable 16 Emergency lighting: Normal and emergency bi-pin 18-110/127 V - 220/240 V non-armoured cable 20-110/127 V - 220/240 V armoured cable 22-110/127 V - 220/240 V single phase loop in loop out through wiring 24-220/240 V AC and 110 V DC 26-230/240 V self-test non-armoured cable 28 Mono-pin fluorescent luminaires - 110/127 V - 220/240 V armoured or non-armoured cable 30 - Normal-emergency 220/240 V armoured or non-armoured cable 32 Level gauge light fitting 110/127 V - 220/240 V non-armoured cable 34 Dimensions of fixing accessories 36 Installation method for fluorescent luminaires 38 Bi-pin metal-glass fluorescent luminaires - 220/240 V non-armoured cable 40 - Normal-emergency 220/240V non-armoured cable 42 Intrinsic and increased safety torches dual lens 45 Intrinsic and increased safety torches 2 cell and 3 cell 46 Round bulkhead light non-armoured cable 47 European Directive and bi-pin fluorescent luminaires 48 Equipment for zones 2 and 22 110/127 V - 220/240 V bi-pin fluorescent luminaires armoured and non-armoured cable - heavy duty 50 - light duty 52 220/240 V normal-emergency fluorescent luminaires - heavy duty 54 - light duty 56 Zone 2 and 22 floodlights armoured and non-armoured cable 58 Zone 2 and 22 round bulkhead light armoured and non-armoured cable 59 Zone 2 and 22 wellglass luminaires armoured and non-armoured cable 60 EGS Group 63 Spare parts 290 Certificates 292 ATX guide 302

10 110/127 V and 220/240 V bi-pin fluorescent luminaires for non-armoured cable increased safety 0963 73 Fluo 2 x 58 W 0965 48 Fluo 2 x 18 W 0965 55 Fluo 2 x 36 W 0963 90 Pole-mounting fluo 2 x 18W 18, 36 and 58 W fluorescent luminaires Ø 26 mm mono and bi-pin tubes, standard G13 lampholders Frequency : 50/60 Hz Power supply via high frequency ballast depending on version : 110/127 V ± 10% AC/DC or 220/240 V~ ± 10%, 198 to 264 V Instant start. Power factor 0.95 2 channel ballast Pre-impregnated fibre glass reinforced polyester body Polycarbonate diffuser hinged to body Polycarbonate multi-parabolic hinged reflector High temperature internal wiring Elastomer gasket Anti-vibration lampholders with spring system Power supply to the unit cut off by positive safety switch which operates when diffuser is opened, for replacing tubes with mains power switched on If one tube fails, the other tubes remain lit. Open and close using an Allen key or flat screwdriver (system automatically protects against over turning of the key or screwdriver) IP 2X terminal strip cover for maintaining the ballast and lampholders without cutting off the mains power supply Ballast fixed by screws, equipped with an anti-vibration fast connector Standard single, twin, three-tube versions Three M25 threaded cable entries, two at one end and the third at the opposite end. Supplied with: One M25 polyamide cable gland (sealed Ø 8 to 18.5 mm) Two M25 blanking plugs One 5 x 4 mm 2 max. flexible or 5 x 6 mm 2 max. rigid connection terminal block Tube (W) Weight Volume Cat. No. Cat. No. Pack not supplied (Kg) (dm 3 ) 110/127 V 220/240 V 1 x 18 5.5 32.3 0915 47 0965 47 1 2 x 18 5.5 32.3 0915 48 0965 48 1 1 x 36 7.9 54.2 0915 53 0965 53 1 2 x 36 7.9 54.2 0915 55 0965 55 1 3 x 36 9.9 54.2 0915 34 0965 34 1 1 x 58 9 65 0913 72 0963 72 1 2 x 58 9 65 0913 73 0963 73 1 3 x 58 11 65 0915 42 0965 42 1 Twin tube through-wiring version Three M25 threaded cable entries, two at one end and the third at the opposite end. Supplied with: Two M25 polyamide cable glands (sealed Ø 8 to 18.5 mm) 1 x M25 blanking plug One connection terminal block at each end: 5 x 4 mm 2 max. flexible or 5 x 6 mm 2 max. rigid (2.5 mm 2 internal wiring) Part number in bold : fast moving references Tube (W) Weight Volume Cat. No. Cat. No. Pack not supplied (Kg) (dm 3 ) 110/127 V 220/240 V 2 x 18 5.5 32.3 0915 18 0965 18 1 2 x 36 7.9 54.2 0915 25 0965 25 1 2 x 58 9 65 0913 83 0963 83 1 Twin tube pole mounting version For mounting on pole or Ø 42 mm tubular wall-mounting support with 1 integrated M25 cable gland entry (sealed Ø 8 to 18.5 mm) Supplied with one 3 x 4 mm 2 connection terminal block and internal clamp for anchoring the cable (positive safety) Tube (W) Weight Volume Cat. No. Cat. No. Pack not supplied (Kg) (dm 3 ) 110/127 V 220/240 V 2 x 18 6.2 34.1 0913 90 0963 90 1 2 x 36 8.7 54.2 0913 91 0963 91 1 Fixing accessories Cat. No. Set of 2 half clamps for fixing to 0965 93 1 Ø 49 mm (1 1/2) or Ø 42 mm (1 1/4) tube For fixing to Ø 60 mm (2 ) tube 0965 91 1 Set of 2 zinc-plated steel M8 ring bolts 0965 94 1 for suspending the unit Ø 42 mm galvanized steel pole 0965 95 1 for wall mounting Set of 2 aluminium brackets for 0965 97 1 fixing unit to flat surface. 316 stainless steel version 0965 90 1 Set of 2 aluminium hinged brackets for adjusting 0965 98 1 direction of luminaire when wall-mounted. 316 stainless steel version 0965 74 1 Set of 2 zinc-plated steel brackets for 0965 96 quick fixing with one hand 316 stainless steel version 0965 89 1 Fall prevention fixing kit 0964 05 1 (1.20 m stainless steel chain) for M25 cable entry NEW For special options, please consult us: Ø 38 mm bi-pin tubes Ø 38 mm bi-pin tubes specially designed for low temperatures 3-tube dimmable Special protection of the diffuser against severe chemical attack Lens fall prevention fixing kit Dimensions of fixing accessories (see page 36-37) Installation and connection method (see page 38-39) Spare parts (see page 290) Pack

11 TECHNICAL DATA Zones : 1 and 2 and 21-22 Classification : According to CENELEC: Conforming to ATEX - 94/9 EC Directive and standards EN 50014-18-19 EC 0081 II 2 G for gas EEx ed II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards. EC 0081 II 2 D T = + 85 C : for dust According to IEC: Conforming to IEC standards 60079-0/1/7 Ex eds II C T4 or T5 to Ta max. 40 C horizontal position, lighting facing downwards. DIP A21 TA = + 85 C Approvals : Approved type FLe CENELEC LCIE 98 ATEX 6004 IEC LCIE Ex 98.012 declaration of conformity No. 50201 Conforming to standards EN 60598-1 and IEC 60598-1 for luminaires Conforming to standards EN 50281-1-1 and IEC 61241-1-1 combustible dust Conforming to electromagnetic compatibility (EMC) standards - EN 55015 - EN 61547 Protection index : IP 66/67 according to EN 60529 and IEC 60529 Mechanical resistance: IK10 according to EN 50102 Operating temperature : - 20 C to + 55 C Anticorrosion treatment and climate protection : see page G50 Positive safety : Safety switch for opening luminaire, see glossary Anti-wiring-error connector Dimmable 3-tube operation : Alternate use possible (1, 2 or 3 tubes) controlled by a double switch, available on request Zone 1 & 2-21 & 22 ATEX IEC EC II2 G/D EEx ed IIC T4 or T5 T = 85 C IP 66/67 IK 10 Dimensions (mm) : Standard/through-wiring version 18 W 36 W 217 217 145 400 700 785 1390 145 Pole-mounting version 785 1390 700 1690 258,5 50 411 Ø 42 Photometric data (photometry p. G62) polar curves for a 1000 lm flux, according to NF C 71-120: longitudinal Luminaire symbol according to NF C 71-121 transverse (1 x 18 W) Efficiency 94,8 % NF C 71-121 : 0,86 H + 0,09 T (1 x 36 W) Efficiency 89,3 % NF C 71-121 : 0,81 H + 0,08 T 58 W 36 W 18 W (2 x 18 W) Efficiency 85,1 % NF C 71-121 : 0,78 H + 0,08 T (2 x 36 W) Efficiency 80,5 % NF C 71-121 : 0,73 H + 0,07 T 50 (3 x 36 W) Efficiency 68,1 % NF C 71-121 : 0,63 G + 0,05 T Ø 42 Central tube lit 2 tubes lit 3 tubes lit Product features/customer benefits - Positive safety switch : Safety Plus - Multi-parabolic reflector : increased efficiency - Ballast with plug in connectors : rapid, error-free maintenance - Opening system automatically protected : no over turning of the key or screwdriver possible - Standard 3-tube : increased light intensity, fewer units, installation possible at increased height - 3-tube dimmable : alternate use of the tubes with a double switch, flexibility of use (1 x 58 W) Efficiency 87,5 % NF C 71-121 : 0,80 H + 0,07 T (2 x 58 W) Efficiency 76,9 % NF C 71-121 : 0,70 H + 0,07 T (3 x 58 W) Efficiency 65,6 % NF C 71-121 : 0,61 G + 0,04 T Data sheet available on request

12 110/127 V and 220/240 V bi-pin fluorescent luminaires for armoured cable increased safety 0963 43 Fluo 2 x 58 W 0965 45 Fluo 2 x 36 W 0965 38 Fluo 2 x 18 W 18, 36 and 58 W fluorescent luminaires Ø 26 mm bi-pin tubes, standard G 13 lampholders Frequency: 50/60 Hz Power supply via high frequency ballast depending on version : 110/127 V ± 10% AC/DC or 220/240 V~ ± 10%, 198 to 264 V Instant start. Power factor 0.95 2 channel ballast Pre-impregnated fibre glass reinforced polyester body Polycarbonate diffuser hinged to body Polycarbonate multi-parabolic hinged reflector High temperature internal wiring Elastomer gasket Anti-vibration lampholders with spring system Power supply to the unit cut off by positive safety switch which operates when diffuser is opened, for replacing tubes with mains power switched on If one tube fails, the other tubes remain lit. Open and close using an Allen key or flat screwdriver (system automatically protects against over turning) IP 2X terminal strip cover for maintaining the ballast and lampholders without cutting off the mains power supply Ballast fixed by screws, equipped with an anti-vibration fast connector Standard single, twin, three-tube version Two M20 threaded cable entries with earth continuity plate for armoured cables at one end (cable gland not supplied) One clearance hole for M20 cable gland at the opposite end Supplied with: Two M20 blanking plugs and one M20 locknut One 5 x 4 mm 2 max. flexible or 5 x 6 mm 2 max. rigid connection terminal block Tube (W) Weight Volume Cat. No. Cat. No. Pack not supplied (Kg) (dm 3 ) 110/127 V 220/240 V 1 x 18 5.5 32.3 0915 35 0965 35 1 2 x 18 5.5 32.3 0915 38 0965 38 1 1 x 36 7.9 54.2 0915 43 0965 43 1 2 x 36 7.9 54.2 0915 45 0965 45 1 3 x 36 9.9 54.2 0915 39 0965 39 1 1 x 58 9 65 0913 42 0963 42 1 2 x 58 9 65 0913 43 0963 43 1 3 x 58 11 65 0915 49 0965 49 1 Through-wiring version with possibility of phase balancing Three M20 threaded cable entries with earth continuity plate for armoured cables, 2 cable entries at one end, and the third at the opposite end (cable gland not supplied) Supplied with: 1 x M20 blanking plug One 5 x 4 mm 2 max. flexible or 5 x 6 mm 2 max. rigid (2.5 mm 2 internal wiring) connection terminal block at each end Tube (W) Weight Volume Cat. No. Cat. No. Pack not supplied (Kg) (dm 3 ) 110/127 V 220/240 V 2 x 18 5.5 32.3 0913 50 0963 50 1 2 x 36 7.9 54.2 0915 15 0965 15 1 2 x 58 9 65 0913 53 0963 53 1 Fixing accessories NEW Cat. No. Set of 2 half clamps for fixing to 0965 93 1 Ø 49 mm (1 1/2) or Ø 42 mm (1 1/4) tube For fixing to Ø 60 mm (2 ) tube: 0965 91 1 Set of 2 zinc-plated steel M8 ring bolts 0965 94 1 for suspending the unit Set of 2 aluminium brackets for 0965 97 1 fixing unit to flat surface. 316 stainless steel version 0965 90 1 Set of 2 aluminium hinged brackets for adjusting 0965 98 1 direction of luminaire when wall-mounted. 316 stainless steel version 0965 74 1 Set of 2 zinc-plated brackets for 0965 96 1 quick fixing with one hand 316 stainless steel version 0965 89 1 Fall prevention fixing kit 0964 06 1 (1.20 m stainless steel chain) for M20 cable entry For special options, please consult us: Ø 38 mm bi-pin tubes Ø 38 mm bi-pin tubes specially designed for low temperatures 3-tube dimmable Special protection of the diffuser against severe chemical attack Lens fall prevention fixing kit Dimensions of fixing accessories (see page 36-37) Installation and connection method (see page 38-39) Spare parts (see page 290) Cable glands for armoured cable (see pages 252-262) Pack Part number in bold : fast moving references

13 TECHNICAL DATA Zones : 1 and 2 and 21-22 Classification : According to CENELEC: Conforming to ATEX - 94/9 EC Directive and standards EN 50014-18-19 EC 0081 II 2 G for gas EEx ed II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards EC 0081 II 2 D T = + 85 C: for dust According to IEC: Conforming to IEC standards 60079-0/1/7 Ex eds II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards. DIP A21 TA = + 85 C Approvals : Approved type FLe CENELEC LCIE 98 ATEX 6004 IEC LCIE Ex 98.012 declaration of conformity No. 50201 Conforming to standards EN 60598-1 and IEC 60598-1 for luminaires Conforming to standards EN 50281-1-1 and IEC 61241-1-1 combustible dust Conforming to electromagnetic compatibility (EMC) standards - EN 55015 - EN 61547 Zone 1 & 2-21 & 22 ATEX IEC EC II2 G/D EEx ed IIC T4 or T5 T = 85 C IP 66/67 IK 10 Dimensions (mm) : Standard/through-wiring version 18 W 36 W 400 700 217 785 1390 145 700 1690 Photometric data (photometry p. G62) polar curves for a 1000 lm flux, according to NF C 71-120 : longitudinal Luminaire symbol according to NF C 71-121 transverse (1 x 18 W) Efficiency 94,8 % NF C 71-121 : 0,86 H + 0,09 T 58 W (2 x 18 W) Efficiency 85,1 % NF C 71-121 : 0,78 H + 0,08 T Protection index : IP 66/67 according to EN 60529 and IEC 60529 Mechanical resistance: IK10 according to EN 50102 Operating temperature : - 20 C to + 55 C Anticorrosion treatment and climate protection : see page G50 (1 x 36 W) Efficiency 89,3 % NF C 71-121 : 0,81 H + 0,08 T (2 x 36 W) Efficiency 80,5 % NF C 71-121 : 0,73 H + 0,07 T (3 x 36 W) Efficiency 68,1 % NF C 71-121 : 0,63 G + 0,05 T Positive safety : Safety switch for opening luminaire, see glossary Anti-wiring-error connector Dimmable 3-tube operation : Alternate use possible (1, 2 or 3 tubes) controlled by a double switch, available on request Central tube lit 2 tubes lit 3 tubes lit (1 x 58 W) Efficiency 87,5 % NF C 71-121 : 0,80 H + 0,07 T (2 x 58 W) Efficiency 76,9 % NF C 71-121 : 0,70 H + 0,07 T (3 x 58 W) Efficiency 65,6 % NF C 71-121 : 0,61 G + 0,04 T Product features/customer benefits - Positive safety switch : Safety Plus - Multi-parabolic reflector : increased efficiency - Ballast with plug in connectors : rapid, error-free maintenance - Opening system automatically protected : no over turning possible - Standard 3-tube : increased light intensity, fewer units, installation possible at increased height - 3-tube dimmable : alternate use of the tubes with a double switch, flexibility of use Data sheet available on request

14 110/127 V or 220/240 V bi-pin single phase loop in loop out connection and through wiring fluorescent luminaires for armoured cable increased safety 0963 09 Fluo 2 x 58 W 0963 08 Fluo 2 x 36 W 0963 07 Fluo 2 x 18 W 18, 36 and 58 W fluorescent luminaires Ø 26 mm bi-pin tubes, standard G 13 lampholders Designed for single phase mains supplies with a choice of possible installation methods: terminal position loop in loop out connection and through wiring Frequency: 50/60 Hz Power supply via high frequency ballast depending on version : 110/127 V ± 10% AC/DC or 220/240 V~ ± 10%, 198 to 264 V Instant start. Power factor 0.95 2 channel ballast Pre-impregnated fibre glass reinforced polyester body Polycarbonate diffuser hinged to body Polycarbonate multi-parabolic hinged reflector High temperature internal wiring Elastomer gasket Anti-vibration lampholders with spring system Power supply to the unit cut off by positive safety switch which operates when diffuser is opened, for replacing tubes with mains power switched on If one tube fails, the other tube remains lit. Open and close using an Allen key or flat screwdriver (system automatically protects against over turning) IP 2X terminal strip cover for maintaining the ballast and lampholders without cutting off the mains power supply Ballast fixed by screws, equipped with a fast connector Three M20 threaded cable entries with earthing plates for armoured cable (cable gland not supplied) Supplied with: Two M20 blanking plugs One connection terminal block at each end 4 x 4mm 2 flexible or 4 x 6mm 2 rigid max., including 1 earth terminal Single phase dual loop in loop out connection/through wiring version Tube (W) Weight Volume Cat. No. Cat. No. Pack not supplied (Kg) (dm 3 ) 110/127 V 220/240 V 2 x 18 5.5 32.3 0913 07 0963 07 1 2 x 36 7.9 54.2 0913 08 0963 08 1 2 x 58 9 65 0913 09 0963 09 1 Fixing accessories Cat. No. Set of 2 half clamps for fixing to 0965 93 1 Ø 49 mm (1 1/2) or Ø 42 mm (1 1/4) tube For fixing to Ø 60 mm (2 ) tube 0965 91 1 Set of 2 zinc-plated steel M8 ring bolts 0965 94 1 for suspending the unit Set of 2 aluminium brackets for fixing 0965 97 1 unit to flat surface. 316 stainless steel version 0965 90 1 Set of 2 aluminium hinged brackets for adjusting 0965 98 1 direction of luminaire when wall-mounted. 316 stainless steel version 0965 74 1 Set of 2 zinc-plated steel brackets for 0965 96 1 quick fixing with one hand 316 stainless steel version 0965 89 1 Fall prevention fixing kit 0964 06 1 (1.20 m stainless steel chain) for M20 cable entry NEW For special options, please consult us: Ø 38 mm bi-pin tubes Ø 38 mm bi-pin tubes specially designed for low temperatures 3-tube dimmable Special protection of the diffuser against severe chemical attack Lens fall prevention fixing kit Dimensions of fixing accessories (see page 36-37) Installation and connection method (see page 38,39) Spare parts (see page 290) Cable glands for armoured cable (see pages 252-262) Pack Part number in bold : fast moving references

15 TECHNICAL DATA Zones : 1 and 2 and 21-22 Classification : According to CENELEC: Conforming to ATEX - 94/9 EC Directive and standards EN 50014-18-19 EC 0081 II 2 G: for gas EEx ed II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards. EC 0081 II 2 D T = +85 C for dust According to IEC: Conforming to IEC standards 60079-0/1/7 Ex eds II C T4 or T5 to Ta max. 40 C horizontal position, lighting facing downwards. DIP A21 TA = + 85 C Approvals : Approved type FLe CENELEC LCIE 98 ATEX 6004 IEC LCIE Ex 98.012 declaration of conformity No. 50201 Conforming to standards EN 60598-1 and IEC 60598-1 for luminaires Conforming to standards EN 50281-1-1 and IEC 61241-1-1 combustible dust Conforming to electromagnetic compatibility (EMC) standards - EN 55015 - EN 61547 Zone 1 & 2-21 & 22 ATEX IEC EC II2 G/D EEx ed IIC T4 or T5 T = 85 C IP 66/67 IK 10 Dimensions (mm) : Single phase loop in loop out connection/through wiring version 18 W 217 400 700 785 1390 145 58 W Photometric data (photometry p. G62) polar curves for a 1000 lm flux, according to NF C 71-120 : longitudinal Luminaire symbol according to NF C 71-121 transverse (2 x 18 W) Efficiency 85,1 % NF C 71-121 : 0,78 H + 0,08 T 36 W 700 1690 Protection index : IP 66/67 according to EN 60529 and IEC 60529 Impact resistance: IK10 according to EN 50102 Operating temperature : - 20 C to + 55 C Anticorrosion treatment and climate protection : see page G50 (2 x 36 W) Efficiency 80,5 % NF C 71-121 : 0,73 H + 0,07 T Positive safety : Safety switch for opening luminaire, see glossary Anti-wiring-error connector (2 x 58 W) Efficiency 76,9 % NF C 71-121 : 0,70 H + 0,07 T Product features/customer benefits - Positive safety switch : Safety Plus - Multi-parabolic reflector : increased efficiency - Ballast with plug in connectors : rapid error-free maintenance - Opening system automatically protected : no over turning possible Data sheet available on request

16 254 V bi-pin fluorescent luminaires for armoured or non-armoured cable increased safety 0963 64 Fluo 2 x 36 W 0963 63 Fluo 2 x 18 W 18 and 36 W fluorescent luminaires Ø 26 mm bi-pin tubes, standard G 13 lampholders Frequency: 50/60 Hz Power supply via high frequency electronic ballast 254 V + 6% - 10%, 229 to 269 V Instant start. Power factor 0.95 2 channel ballast Pre-impregnated fibre glass reinforced polyester body Polycarbonate diffuser hinged to body Polycarbonate multi-parabolic hinged reflector High temperature internal wiring Elastomer gasket Anti-vibration lampholders with spring system Power supply to the unit cut off by positive safety switch which operates when diffuser is opened, for replacing tubes with mains power switched on If one tube fails, the other tube remains lit. Open and close using an Allen key or flat screwdriver (system can be disengaged at end of travel) IP 2X terminal strip cover for maintaining the ballast and lampholders without cutting off the mains power supply Ballast fixed by screws, equipped with a fast connector Standard twin version for non-armoured cable Three threaded cable entries, 2 at one end and the third at the opposite end for M25 cable gland. Supplied with: One M25 polyamide cable gland (sealed Ø 8 to 18.5 mm) Two M25 blanking plugs One 5 x 4 mm 2 max. flexible or 5 x 6 mm 2 max. rigid connection terminal block Tube (W) Weight Volume Cat. No. Pack not supplied (Kg) (dm 3 ) 254V 2 x 18 5.5 32.3 0963 63 1 2 x 36 7.9 54.2 0963 64 1 Standard twin version for armoured cable Two M20 threaded cable entries with earthing plate for armoured cable at one end (cable gland not supplied) One clearence hole for M20 cable gland at the opposite end Supplied with Two M20 blanking plugs and one M20 locknut One 5 x 4 mm 2 max. flexible or 5 x 6 mm 2 max. rigid connection terminal block Tube (W) Weight Volume Cat. No. Pack not supplied (Kg) (dm 3 ) 254V 2 x 18 5.5 32.3 0963 74 1 2 x 36 7.9 54.2 0963 75 1 Fixing accessories Cat. No. Set of 2 half clamps for fixing under 0965 93 1 Ø 49 mm (1 1/2) or Ø 42 mm (1 1/4) tube For fixing under Ø 60 mm (2 ) tube 0965 91 1 Set of 2 zinc-plated steel M8 ring bolts 0965 94 1 for suspending the unit Set of 2 aluminium brackets for fixing 0965 97 1 unit to flat surface. 316 stainless steel version 0965 90 1 Set of 2 aluminium hinged brackets for adjusting 0965 98 1 direction of luminaire when wall-mounted. 316 stainless steel version 0965 74 1 Set of 2 zinc-plated brackets for 0965 96 1 quick fixing with one hand 316 stainless steel version 0965 89 1 Fall prevention fixing kit 0964 06 1 (1.20 m stainless steel chain) for M20 cable entry Fall prevention fixing sling 0964 05 1 (1.20 m stainless steel chain) for M25 cable entry NEW For special options, please consult us: Single tube Fa6 tube Pole mounting version Special protection of the diffuser against severe chemical attack Lens fall prevention fixing kit Dimensions of fixing accessories (see page 36-37) Installation and connection method (see page 38-39) Spare parts (see page 290) Cable glands for armoured cable (see pages 252-262) Pack Part number in bold : fast moving references

17 TECHNICAL DATA Zones : 1 and 2 and 21-22 Classification : According to CENELEC : Conforming to ATEX - 94/9 EC Directive standards EN 50014-18-19 EC 0081 II 2 G : for gas EEx ed II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards. EC 0081 II 2 D T = + 85 C : for dust According to IEC : Conforming to IEC standards 60079-0/1/7 Ex eds II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards DIP A21 TA = + 85 C Approvals : Approved type FLe CENELEC LCIE 98 ATEX 6004 IEC LCIE Ex 98.012 declaration of conformity No. 50201 Conforming to standards EN 60598-1 and IEC 60598-1 for luminaires Conforming to standards EN 50281-1-1 and IEC 61241-1-1 combustible dust Conforming to electromagnetic compatibility (EMC) standards - EN 55015 - EN 61547 Zone 1 & 2-21 & 22 ATEX IEC EC II2 G/D EEx ed IIC T4 or T5 T = 85 C IP 66/67 IK 10 Dimensions (mm) : Standard version 217 145 36 W 18 W Photometric data (photometry p. G62) polar curves for a 1000 lm flux, according to NF C 71-120: longitudinal Luminaire symbol according to NF C 71-121 transverse (2 x 18 W) Efficiency 85,1 % NF C 71-121 : 0,78 H + 0,08 T 785 1390 258,5 50 411 Ø 42 50 Ø 42 Protection index : IP 66/67 according to EN 60529 and IEC 60529 Impact resistance : IK10 according to EN 50102 Operating temperature : - 20 C to + 55 C Anticorrosion treatment and climate protection : see page G50 (2 x 36 W) Efficiency 80,5 % NF C 71-121 : 0,73 H + 0,07 T Positive safety : Safety switch for opening contact luminaire, see glossary Anti-wiring-error connector Product features/customer benefits - Positive safety switch : Safety Plus - Multi-parabolic reflector : increased efficiency - Ballast with connectors : rapid error-free maintenance - Opening mechanism can be disengaged : protected system Data sheet available on request

18 NORMAL - EMERGENCY LIGHTING UNITS ATX emergency lighting : giving you the product, plus many special features Choice of power supply For emergency lighting in hazardous locations, ATX offers fluorescent luminaires with two types of power supply, one centralized with central battery, the other via self-contained units with an integrated battery. Choice between three types of ATEX product Depending on the emergency system and whether it is based on a centralized or self-contained battery, you can choose between three types of product with different functions. You also have the option of manual or automatic tests depending on the range. Beep Beep Beep Memory Central battery (back up) a single electric installation for power supply 220/240 V ~ and 110 V = Self-contained normal-emergency with integrated battery Self-contained normalemergency with auto-test

19 choice of power supply and type of benefits The same benefits as the fluorescent range... The normal-emergency bi-pin fluorescent luminaires incorporate all the technical benefits of the increased safety fluorescent range : safe closing, and easy maintenance. Work can also be performed with the mains power switched on. Plus three special benefits In addition, normal-emergency bi-pin fluorescent luminaires have features specially designed for their applications. See photos below. LED indicates that batteries are charging, and that the unit is in good working order. It also confirms feedback of information for auto-test devices. Two positive safety switches allow work to be carried out with the mains power switched on, by : - Cutting the mains power - Cutting the battery power Plug-in battery pack which is easy to remove in situ with the mains power switched on, for units with integrated battery.

20 110/127 V - 220/240 V normal-emergency bi-pin fluorescent luminaires for non-armoured cable increased safety 0963 54 Fluo 2 x 58 W Charge indicating light 0963 71 Fluo 2 x 36 W 0963 70 Fluo 2 x 18 W 18, 36 and 58 W fluorescent luminaires for normal and emergency lighting Ø 26 mm bi-pin tubes, standard G13 lampholders Frequency : 50/60 Hz Common power supply circuit to provide both normal lighting and emergency lighting Power supply via high frequency electronic ballast according to model: 110/127 V ± 10% AC/DC or 220/240 V~ ± 10%, 198 to 264 V Instant start - Power factor 0.95 Battery voltage : 18 W : 6 V 4 A - 36 W/58W : 8.4 V 4 A Pre-impregnated fibre glass reinforced polyester body Polycarbonate multi-parabolic hinged reflector Polycarbonate diffuser hinged to body High temperature internal wiring Elastomer gasket Anti-vibration lampholders with spring system Operation : mains power switched on : 2 or 3 tubes lit mains power switched off : 1 tube lit (battery backed) Power supply to the unit (mains supply and battery) cut off by two positive safety switches which operate when diffuser is opened, for replacing tubes with mains power switched on Green LED on when the installation is operating normally and off in the event of a mains power supply failure or battery fault Battery-backed tube identified with green mark Battery pack easily interchangeable on site, fixed by screws and equipped with a fast plug in connector Ballast and converter assembly fixed by screws, equipped with an antivibration fast connector Open and close using an Allen key or flat screwdriver (system automatically protects against over turning) Standard twin, three-tube version Supplied with one M25 polyamide cable gland (sealed Ø : 8 to 18.5 mm) Two M25 blanking plugs Equipped with an IP 2 X terminal strip cover for maintenance of batteries, ballast and lampholders with mains power switched on 18 W version: one 4 x 4 mm 2 flexible or 4 x 6 mm 2 rigid connection terminal block max. including one earth terminal 36/58W version: one 2 x 4 x 4 mm 2 flexible or 2 x 4 x 6 mm 2 rigid connection terminal block max. including 2 earth terminals Tube (W) 1 tube Light Weight Volume Cat. No. Cat. No. Pack (not supplied) standby time intensity (Kg) (dm 3 ) 110/127 V 220/240 V 2 x 18 3 h 29 % 9.3 54.2 0913 70 1 2 x 18 3 h 29 % 7.3 32.3 0963 70 1 2 x 36 3 h 16 % 9.6 54.2 0913 71 0963 71 1 2 x 58 3 h 11% 10.7 65 0913 54 0963 54 1 3 x 36 3 h 16% 11.6 54.2 0913 84 0963 84 1 3 x 58 3 h 11% 12.7 65 0913 94 0963 94 1 Part number in bold : fast moving references Twin tube through-wiring version Supplied with Two M25 polyamide cable glands (sealed Ø: 8 to 18.5 mm) One M25 blanking plug Two 4 x 4 mm 2 flexible or 4 x 6 mm 2 rigid. connection terminal blocks max. 18W : Maintenance of tubes with mains power switched on, maintenance of batteries, ballast and lampholders on site with mains power switched off 36W : Equipped with IP 2 X terminal strip cover, enabling maintenance of the batteries, ballast and lampholders with the mains power switched on Tube (W) 1 tube Light Weight Volume Cat. No. Cat. No. Pack (not supplied) standby time output (Kg) (dm 3 ) 110/127 V 220/240 V 2 x 18 3 h 29 % 7.3 32.3 0963 80 1 2 x 36 3 h 16 % 9.6 54.2 0913 81 0963 81 1 Twin tube pole mounting version For mounting on pole or tubular wall-mounting support ø 42 mm with one integrated M25 polyamide cable gland (sealed Ø 8 to 18.5 mm) Supplied with one 3 x 4 mm 2 connection terminal block and internal bracket for anchoring the cable (positive safety) Tube (W) 1 tube Light Weight Volume Cat. No. Cat. No. Pack (not supplied) standby time output (Kg) (dm 3 ) 110/127 V 220/240 V 2 x 18 W 3h 29 % 10 54.2 0913 92 0963 92 1 2 x 36 W 3 h 16 % 10.4 54.2 0913 93 0963 93 1 Fixing accessories 0963 92 Pole mounting fluo 2 x 18W Cat. No. Set of 2 half clamps for fixing under 0965 93 1 Ø 49 mm (1 1/2) or Ø 42 mm (1 1/4) tube For fixing under Ø 60 mm (2 ) tube: 0965 91 1 Set of 2 zinc-plated steel M8 ring bolts 0965 94 1 for suspending the unit Ø 42 mm galvanized steel pole 0965 95 1 for wall mounting Set of 2 aluminium brackets for fixing 0965 97 1 unit to flat surface. 316 stainless steel version 0965 90 1 Set of 2 aluminium hinged brackets for adjusting 0965 98 1 direction of luminaire when wall-mounted. 316 stainless steel version 0965 74 1 Set of 2 zinc-plated steel brackets 0965 96 1 for quick fixing with one hand 316 stainless steel version 0965 89 1 Fall prevention fixing kit 0964 05 1 (1.20 m stainless steel chain) for M25 cable entry NEW For special options, please consult us : 1 hr 30 mins standby time, remote batteries, other voltages Dimensions of fixing accessories (see page 36-37) Installation and connection method (see page 38-39) Spare parts (see page 290) Pack

21 TECHNICAL DATA Zones : 1 and 2 and 21-22 Classification : According to CENELEC: Conforming to ATEX - 94/9 EC Directive and standards EN 50014-18-19-28 EC 0081 II 2 G: for gas EEx edm II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards EC 0081 II 2 D - T = + 85 C : for dust According to IEC: Conforming to IEC standards 60079-0/1/7/18 Ex edsm II C T4 or T5 to Ta max. +40 C, horizontal position, lighting facing downwards DIP A21 TA = + 85 C Approvals : Approved type FLe CENELEC LCIE 98 ATEX 6004 IEC LCIE Ex 98.012 declaration of conformity No. 50201 Conforming to standards EN 60598-1 and IEC 60598-1 for luminaires Conforming to standards EN 50281-1-1 and IEC 61241-1-1 combustible dust Conforming to electromagnetic compatibility (EMC) standards - EN 55015 - EN 61547 Protection index : IP 66/67 according to EN 60529 and IEC 60529 Impact resistance : IK10 according to EN 50102 Operating temperature : - 20 C to + 55 C (18/36W) ; - 20 C to + 40 C (58W) Zone 1 & 2-21 & 22 ATEX IEC EC II2 G/D EEx edm IIC T4 or T5 T = 85 C IP 66/67 IK 10 Dimensions (mm) : Standard/through-wiring/pole mounting version : 18 W (220/230 V) 18 W (110/127 V) 217 217 58 W (18/36W) 145 145 400 785 Pole mounting version : 258,5 Photometric data (photometry p. G62) polar curves for a 1000 lm flux, according to NF C 71-120: longitudinal Luminaire symbol according to NF C 71-121 transverse (1 x 36 W) Efficiency 89,3 % NF C 71-121 : 0,81 H + 0,08 T 36 W 700 1690 700 1390 785 1390 (2 x 36 W) Efficiency 80,5 % NF C 71-121 : 0,73 H + 0,07 T 400 990 50 411 Ø 42 50 (3 x 36 W) Efficiency 68,1 % NF C 71-121 : 0,63 G + 0,05 T Ø 42 Anticorrosion treatment and climate protection : see page G50 Positive safety : Safety switch for opening luminaire, see glossary Anti-wiring-error connector Dimmable 3-tube operation : Alternate use possible (1, 2 or 3 tubes) controlled by a double switch, available on request (1 x 58 W) Efficiency 87,5 % NF C 71-121 : 0,80 H + 0,07 T (2 x 58 W) Efficiency 76,9 % NF C 71-121 : 0,70 H + 0,07 T (3 x 58 W) Efficiency 65,6 % NF C 71-121 : 0,61 G + 0,04 T Central tube lit 2 tubes lit 3 tubes lit Fluorescent luminaire on Fluorescent luminaire off Emergency function 2 tubes Mains power on Mains power off Emergency function 3 tubes Fluorescent luminaire on Fluorescent luminaire off Mains power on Mains power off Product features/customer benefits - Automatic switch-off function for mains supply and battery : maintainability in hazardous locations - Positive safety switch : Safety Plus - Multi-parabolic reflector : increased efficiency - Ballast with plug in connectors : rapid error-free maintenance - Battery with plug in connectors : rapid error-free maintenance - Opening system automatically protected : no over turning possible - Standard 3-tube : increased intensity, fewer units required - 3-tube dimmable : alternate use of the tubes with a double switch, flexibility of use Data sheet available on request

22 110/127 V and 220/240 V normal and emergency bi-pin fluorescent luminaires for armoured cable increased safety 0963 44 Fluo 2 x 58 W 0963 41 Fluo 2 x 36 W Charge indicating light 0963 40 Fluo 2 x 18 W 18, 36 and 58 W fluorescent luminaires for normal and emergency lighting Ø 26 mm bi-pin tubes, standard G13 lampholders Frequency : 50/60 Hz Common power supply circuit to provide both normal lighting and emergency lighting Power supply via high frequency electronic ballast depending on version : 110/127 V ± 10% AC/DC or 220/240 V~ ± 10%, 198 to 264 V Instant start - Power factor 0.95 Battery voltage : 18 W : 6 V 4 Ah - 36/58W : 8.4 V 4 Ah Pre-impregnated fibre glass reinforced polyester body Polycarbonate multi-parabolic hinged reflector Polycarbonate diffuser hinged to body High temperature internal wiring Elastomer gasket Anti-vibration lampholders with spring system Operation : mains power switched on : 2 or 3 tubes lit, mains power switched off : 1 tube lit (battery backup) Power supply to the unit (mains supply and battery) cut off by two positive safety switches which operate when diffuser is opened, for replacing tubes with mains power switched on Green LED on when the installation is operating normally and off in the event of a mains power supply failure or battery fault Battery-backed tube identified with green mark Battery pack easily interchangeable on site, fixed by screws and equipped with a fast plug in connector Ballast and converter fixed by screws, equipped with a fast connector Open and close using an Allen key or flat screwdriver (system automatically protects against over turning) Standard version with earthing plate for armoured cable Two M 20 threaded cable entries with earth continuity plate at one end (cable gland not supplied) One clearence hole for M20 cable gland at the opposite end Supplied with : Two M 20 blanking plugs and one M20 locknut Equipped with an IP 2 X terminal strip cover for maintenance of battery, ballast and lampholders with mains power switched on 18W version: one 4 x 4 mm 2 flexible or 4 x 6 mm 2 rigid connection terminal block max. including one earth terminal 36/58 W version: one 2 x 4 x 4 mm 2 flexible or 2 x 4 x 6mm 2 rigid connection terminal block max. including 2 earth terminals Tube (W) 1 tube Light Weight Volume Cat. No. Cat. No. Pack (not supplied) standby time intensity (Kg) (dm 3 ) 110/127 V 220/240 V 2 x 18 3 h 29 % 7.6 32.3 0963 40 1 2 x 18 3 h 29 % 10 54.2 0913 40 1 2 x 36 3 h 16 % 9.9 54.2 0913 41 0963 41 1 2 x 58 3 h 11 % 10.7 65 0913 44 0963 44 1 3 x 36 3 h 16 % 11.6 54.2 0963 85 1 3 x 58 3 h 11 % 12.7 65 0913 95 0963 95 1 Fixing accessories Cat. No. Set of 2 half clamps for fixing to 0965 93 1 Ø 49 mm (1 1/2) or Ø 42 mm (1 1/4) tube For fixing to Ø 60 mm (2 ) tube: 0965 91 1 Set of 2 zinc-plated steel M8 ring bolts 0965 94 1 for suspending the unit Set of 2 aluminium brackets for 0965 97 1 fixing unit to flat surface. 316 stainless steel version 0965 90 1 Set of 2 aluminium hinged brackets for adjusting 0965 98 1 direction of luminaire when wall-mounted. 316 stainless steel version 0965 74 1 Set of 2 zinc-plated steel brackets 0965 96 1 for quick fixing with one hand 316 stainless steel version 0965 89 1 Fall prevention fixing kit 0964 06 1 (1.20 m stainless steel chain) for M20 cable entry NEW For special options, please consult us: 1.5 hour emergency duration Remote batteries Other voltages Emergency unit only Special protection of the diffuser against severe chemical attack Lens fall prevention fixing kit Dimensions of fixing accessories (see page 36-37) Installation and connection method (see page 38-39) Spare parts (see page 290) Cable glands for armoured cable (see pages 252-262) Pack Part number in bold : fast moving references

23 TECHNICAL DATA Zones : 1 and 2 and 21-22 Classification : According to CENELEC : Conforming to ATEX - 94/9 EC Directive and standards EN 50014-18-19 EC 0081 II 2 G: for gas EEx edm II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards EC 0081 II 2 D - T = + 85 C : for dust According to IEC : Conforming to IEC standards 60079-0/1/7 Ex edsm II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards DIP A21 TA = + 85 C Approvals : Approved type FLe CENELEC LCIE 98 ATEX 6004 IEC LCIE Ex 98.012 declaration of conformity No. 50201 Conforming to standards EN 60598-1 and IEC 60598-1 for luminaires Conforming to standards EN 50281-1-1 and IEC 61241-1-1 combustible dust Conforming to electromagnetic compatibility (EMC) standards - EN 55015 - EN 61547 Zone 1 & 2-21 & 22 ATEX IEC EC II2 G/D EEx edm IIC T4 or T5 T = + 85 C IP 66/67 IK 10 Dimensions (mm) : Standard version 18 W (220/230 V) 18 W (110/127 V) 217 58 W 145 400 785 36 W Photometric data (photometry p. G62) polar curves for a 1000 lm flux, according to NF C 71-120: longitudinal Luminaire symbol according to NF C 71-121 transverse (1 x 36 W) Efficiencyt 89,3 % NF C 71-121 : 0,81 H + 0,08 T 700 1690 700 1390 (2 x 36 W) Efficiency 80,5 % NF C 71-121 : 0,73 H + 0,07 T 400 990 (3 x 36 W) Efficiency 68,1 % NF C 71-121 : 0,63 G + 0,05 T Protection index : IP 66/67 according to EN 60529 and IEC 60529 Impact resistance : IK10 according to EN 50102 Operating temperature : - 20 C to + 55 C (18/36W) ; - 20 C to + 40 C (58W) Anticorrosion treatment and climate protection : Page : G50 (1 x 58 W) Efficiency 87,5 % NF C 71-121 : 0,80 H + 0,07 T (2 x 58 W) Efficiency 76,9 % NF C 71-121 : 0,70 H + 0,07 T (3 x 58 W) Efficiency 65,6 % NF C 71-121 : 0,61 G + 0,04 T Positive Safety Plus : Safety switch for opening luminaire, see glossary Anti-wiring-error connector Dimmable 3-tube operation : Alternate use possible (1, 2 or 3 tubes) controlled by a double switch, available on request Central tube lit 2 tubes lit 3 tubes lit Fluorescent luminaire on Fluorescent luminaire off Emergency function 2 tubes Mains power on Mains power off Emergency function 3 tubes Fluorescent luminaire on Fluorescent luminaire off Mains power on Mains power off Product features/customer benefits - Automatic switch-off function for mains supply and battery : maintenance in hazardous areas - Positive safety switch : Safety Plus - Multi-parabolic reflector : increased efficiency - Ballast with plug in connectors : rapid error-free maintenance - Battery with connectors : rapid error-free maintenance - Opening system automatically protected : no over turning possible - Standard 3-tube : increased intensity, fewer units required - 3-tube dimmable : alternate use of the tubes with a double switch, flexibility of use Data sheet available on request

24 110/127 V or 220/240 V single phase loop in loop out connection and through wiring normal-emergency for armoured cable increased safety 0963 22 Fluo 2 x 58 W 0963 31 Fluo 2 x 36 W 0963 30 Fluo 2 x 18 W 18, 36 and 58 W fluorescent luminaire for normal and emergency lighting Ø 26 mm bi-pin tubes, standard G13 lampholders Designed for single phase mains supplies with a choice of possible installation methods: terminal position, connection and through wiring Frequency : 50/60 Hz Common power supply circuit to provide both normal lighting and emergency lighting Power supply via high frequency electronic ballast depending on the version : 110/127 V ± 10% AC/DC or 220/240 V~ ± 10%, 198 to 264 V Instant start - Power factor 0.95 Battery voltage : 18 W : 6 V 4 Ah - 36/58W : 8.4 V 4 Ah Pre-impregnated fibre glass reinforced polyester body Polycarbonate multi-parabolic hinged reflector Polycarbonate diffuser hinged to body High temperature internal wiring Elastomer gasket Anti-vibration lampholders with spring system Operation: mains power switched on : 2 tubes lit mains power switched off : 1 tube lit (battery backup) Power supply to the unit (mains supply and battery) cut off by two positive safety switches, which operate when diffuser is opened, for replacing tubes with mains power switched on Green LED on when the installation is operating normally and off in the event of a mains power supply failure or a battery fault Battery-backed tube identified with green mark Open and close using an Allen key or flat screwdriver (system automatically protects against over turning) Battery pack easily interchangeable on site, fixed by screws and equipped with a fast plug in connector Ballast and converter fixed by screws, equipped with a fast connector 36/58 W equipped with an IP 2 X terminal strip cover for maintenance of battery, ballast and lampholders with mains power switched on 18W maintenance of the tubes with the mains power switched on, maintenance of the battery, ballast and lampholders with the mains power absent. Three threaded cable entries with earthing plates for M20 cable gland (not supplied) for armoured cable Supplied with: Two M20 blanking plugs 18 W : 4 X 4 mm 2 flexible or 8 x 6 mm 2 rigid connection terminal block max. including one earth terminal at one end One 4 x 4 mm 2 flexible or 4 x 6 mm 2 rigid loop in loop out terminal block including one earth terminal at the other end Catalogue numbers Tube (W) 1 tube Light Weight Volume Cat. No. Cat. No. Pack (not supplied) standby time intensity (Kg) (dm 3 ) 110/127 V 220/240 V 2 x 18 3 h 29% 7.6 32.3 0963 30 1 2 x 18 3 h 29% 10 54.2 0913 40(*) 1 2 x 36 3 h 16 % 9.9 54.2 0913 31 0963 31 1 2 x 58 3 h 11 % 10.7 65 0913 32 0963 32 1 (*) reference 0913 40 possible installation methods : - terminal position and connection : YES - through wiring : NO Fixing accessories Charge indicating light Cat. No. Set of 2 half clamps for fixing to 0965 93 1 Ø 49 mm (1 1/2) or Ø 42 mm (1 1/4) tube For fixing to Ø 60 mm (2 ) tube: 0965 91 1 Set of 2 zinc-plated steel M8 ring bolts 0965 94 1 for suspending the unit Set of 2 aluminium brackets for fixing 0965 97 1 unit to flat surface 316 stainless steel version 0965 90 1 Set of 2 aluminium hinged brackets for adjusting 0965 98 1 the direction of the luminaire when wall-mounted 316 stainless steel version 0965 74 1 Set of 2 zinc-plated steel brackets for 0965 96 1 quick fixing with one hand 316 stainless steel version 0965 89 1 Fall prevention fixing kit 0964 06 1 (1.20 m stainless steel chain) for M20 cable entry NEW For special options, please consult us : 1,5 hour emergency duration Remote battery Other voltages Lens fall prevention fixing kit Dimensions of fixing accessories (see page 36-37) Installation and connection method (see page 38-39) Spare parts (see page 290) Cable glands for armoured cable (see pages 252-262) Pack Part number in bold : fast moving references

25 TECHNICAL DATA Zones : 1 and 2 and 21-22 Classification : According to CENELEC : Conforming to ATEX - 94/9 EC Directive and standards EN 50014-18-19 EC 0081 II 2 G : for gas EEx edm II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards EC 0081 II 2 D - T = + 85 C : for dust According to IEC : Conforming to IEC standards 60079-0/1/7 Ex edsm II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards DIP A21 TA = + 85 C Approvals : Approved type FLe CENELEC LCIE 98 ATEX 6004 IEC LCIE Ex 98.012 declaration of conformity No. 50201 Conforming to standards EN 60598-1 and IEC 60598-1 for luminaires Conforming to standards EN 50281-1-1 and IEC 61241-1-1 combustible dust Conforming to electromagnetic compatibility (EMC) standards - EN 55015 - EN 61547 Protection index : IP 66/67 according to EN 60529 and IEC 60529 Impact resistance : IK10 according to EN 50102 Operating temperature : - 20 C to + 55 C (18/36 W) ; - 20 C to + 40 C (58 W) Anticorrosion treatment and climate protection : see page G50 Zone 1 & 2-21 & 22 ATEX IEC EC II2 G/D EEx edm IIC T4 or T5 T = 85 C IP 66/67 IK 10 Dimensions (mm) : Single phase loop in loop out connection/through wiring version 18 W (220/230 V) 18 W (110/127 V) 217 58 W 145 400 785 36 W 700 1690 Photometric data (photometry p. G62) polar curves for a 1000 lm flux, according to NF C 71-120: longitudinal Luminaire symbol according to NF C 71-121 transverse (2 x 18 W) Efficiency 85,1 % NF C 71-121 : 0,78 H + 0,08 T 700 1390 400 990 Positive Safety Plus : Safety switch for opening luminaire, see glossary Anti-wiring-error connector (2 x 36 W) Efficiency 80,5 % NF C 71-121 : 0,73 H + 0,07 T Emergency function 2 tubes Mains power switched on Mains power switched on Fluorescent luminaire on Fluorescent luminaire off (2 x 58 W) Efficiency 76,9 % NF C 71-121 : 0,70 H + 0,07 T Product features/customer benefits - Automatic switch-off function for mains supply and battery : maintenance in hazardous areas - Positive safety switch : Safety Plus - Multi-parabolic reflector : increased efficiency - Ballast with plug in connectors : rapid error-free maintenance - Battery with plug in connectors : rapid error-free maintenance - Opening system automatically protected : no over turning possible Data sheet available on request

26 220/240 V AC or 110 V DC normal and emergency bi-pin luminaires for central source for armoured and non-armoured cable increased safety 0963 12 Fluo 2 x 36W 0963 10 Fluo 2 x 18W 18 and 36 W fluorescent luminaires Ø 26 mm bi-pin tubes, standard G 13 lampholders Power supply via high frequency ballast for alternate use: in normal mode: 220/240 V~ ± 10%, 198 to 264 V 50/60 Hz in battery back up mode 3 hours maximum: 110 V DC on remote battery powered by the mains supply Pre-impregnated fibre glass reinforced polyester body Polycarbonate diffuser hinged to body Polycarbonate multi-parabolic hinged reflector High temperature internal wiring Elastomer gasket Anti-vibration lampholders with spring system Power supply to the unit cut off by positive safety switch which operates when diffuser is opened, for replacing tubes with mains power switched on If one tube fails, the other tube remains lit. Open and close using an Allen key or flat screwdriver (system automatically protects against over turning) IP 2X terminal strip cover for maintaining the ballast and lampholders without cutting off the mains power supply Ballast fixed by screws, equipped with a fast connector Standard twin version for non-armoured cable Three threaded cable entries, 2 at one end and the third at the opposite end for M25 cable gland. Supplied with: One M25 polyamide cable gland (sealed Ø 8 to 18.5 mm) Two M25 blanking plugs One 5 x 4 mm 2 max. flexible or 5 x 6 mm 2 max. rigid connection terminal block Tube (W) Light Weight Volume Cat. No. Pack not supplied output (Kg) (dm 3 ) 220/240 V 2 x 18 100 % 5.5 32.3 0963 10 1 2 x 36 100 % 7.9 54.2 0963 12 1 Standard twin version for armoured cable Two M20 threaded cable entries with earth continuity plate for cable gland (not supplied) for armoured cable at one end One clearence hole for M20 cable gland at the opposite end Supplied with: Two M20 blanking plugs and one M20 locknut One 5 x 4 mm 2 max. flexible or 5 x 6 mm 2 max. rigid connection terminal block Tube (W) Light Weight Volume Cat. No. Pack not supplied output (Kg) (dm 3 ) 220/240V 2 x 18 100 % 5.5 32.3 0963 18 1 2 x 36 100 % 7.9 54.2 0963 20 1 Fixing accessories Cat. No. Set of 2 half clamps for fixing to 0965 93 1 Ø 49 mm (1 1/2) or Ø 42 mm (1 1/4) tube For fixing to Ø 60 mm (2 ) tube 09665 91 1 Set of 2 zinc-plated steel M8 ring bolts 0965 94 1 for suspending the unit Set of 2 aluminium brackets for fixing 0965 97 1 unit to flat surface. 316 stainless steel version 0965 90 1 Set of 2 aluminium hinged brackets for adjusting 0965 98 1 direction of luminaire when wall-mounted. 316 stainless steel version 0965 74 1 Set of 2 zinc-plated steel brackets for 0965 96 1 quick fixing 316 stainless steel version 0965 89 1 Fall prevention fixing kit 0964 06 1 (1.20 m chain) for M20 cable entry Fall prevention fixing sling 0964 05 1 (1.20 m stainless steel chain) for M25 cable entry NEW For special options, please consult us : Through wiring and pole mounting versions Single tube and Fa6 tube versions Ø 38 mm bi-pin tubes Ø 38 mm bi-pin tubes specially designed for low temperatures Special protection of the diffuser against severe chemical attack Lens fall prevention fixing kit Dimensions of fixing accessories (see page 36-37) Installation and connection method (see page 38-39) Spare parts (see page 290) Cable glands for armoured cable (see pages 252-262) Pack Part number in bold : fast moving references

27 TECHNICAL DATA Zones : 1 and 2 and 21-22 Classification : According to CENELEC: Conforming to ATEX - 94/9 EC Directive and standards EN 50014-18-19 EC 0081 II 2 G : for gas EEx ed II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards. EC 0081 II 2 D T = + 85 C : for dust According to IEC : Conforming to IEC standards 60079-0/1/7 Ex eds II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards. DIP A21 TA = + 85 C Approvals : Approved type Fle CENELEC LCIE 98 ATEX 6004 IEC LCIE Ex 98.012 declaration of conformity No. 50201 Conforming to standards EN 60598-1 and IEC 60598-1 for luminaires Conforming to EN 50281-1-1 and IEC 61241-1-1 combustible dust Conforming to electromagnetic compatibility (EMC) standards - EN 55015 - EN 61547 Zone 1 & 2-21 & 22 ATEX IEC EC II2 G/D EEx ed IIC T4 or T5 T = 85 C IP 66/67 IK 10 Dimensions (mm) : 217 145 36 W 18 W 785 1390 258,5 50 411 Ø 42 Photometric data (photometry p. G62) polar curves for a 1000 lm flux, according to NF C 71-120: longitudinal Luminaire symbol according to NF C 71-121 transverse (2 x 18 W) Efficiency 85,1 % NF C 71-121 : 0,78 H + 0,08 T 50 Ø 42 Protection index : IP 66/67 according to EN 60529 and IEC 60529 Impact resistance : IK10 according to EN 50102 Operating temperature : - 20 C to + 55 C Anticorrosion treatment and climate protection : see page G50 Positive safety : Safety switch for opening luminaire, see glossary Anti-wiring-error connector (2 x 36 W) Efficiency 80,5 % NF C 71-121 : 0,73 H + 0,07 T Product features/customer benefits - Positive safety switch : Safety Plus - Multi-parabolic reflector : increased efficiency - Ballast with plug in connectors : rapid error-free maintenance - Opening system automatically protected : no over turning possible Data sheet available on request

28 230/240 V self-test normal and emergency bi-pin fluorescent luminaires for non-armoured cable increased safety Memory 0963 19 Fluo 2 x 36W 0963 38 Fluo 2 x 58W Beep Beep Beep Visible and audible fault signal 0963 17 Fluo 2 x 18W 18, 36 and 58 W auto-test fluorescent luminaires for normal and emergency lighting Ø 26 mm mono and bi-pin tubes, standard G13 lampholders Frequency: 50/60 Hz Common power supply circuit to provide both normal lighting and emergency lighting Power supply via high frequency ballast 230/240 V~ ± 6%; 216 to 256 V~ Instant start - Power factor 0.96 Battery voltage : 18W, 36W and 58W - 6V Pre-impregnated fibre glass reinforced polyester body Polycarbonate multi-parabolic hinged reflector Polycarbonate diffuser hinged to body High temperature internal wiring Elastomer gasket Anti-vibration lampholders with spring system Power supply to the unit (mains supply and battery) cut off by two positive safety switches which operate when diffuser is opened, for replacing tubes with mains power switched on Operation : mains power switched on : 2 tubes lit mains power switched off : 1 tube lit (battery backed) Automatic tests controlled by microprocessor: monthly : discharge for 5 minutes 6-monthly : discharge for 1 hour annual : discharge for 3 hours with indication (upon request) of the number of months remaining before the next test In the event of a fault: LED flashes Buzzer emits 3 long beeps every 35 minutes until the repair is carried out Battery-backed tube identified with green mark Open and close using an Allen key or flat screwdriver (system automatically protects against over turning) battery pack easily interchangeable on site, fixed by screws and equipped with a fast connector Ballast and converter fixed by screws, equipped with a fast connector Standard twin version for non-armoured cable Supplied with : One M25 polyamide cable gland (sealed Ø: 8 to 18.5mm) Two M25 blanking plugs 18W version : one 4 x 4 mm 2 flexible or 4 x 6 mm 2 rigid connection terminal block max. including one earth terminal 36/58 W version: one 2 x 4 x 4 mm 2 flexible or 2 x 4 x 6mm 2 rigid connection terminal block max. including 2 earth terminals Tube (W) 1 tube Light Weight Volume Cat. No Pack not supplied standby intensity (kg) (dm 3 ) 230/240 V 2 x 18 3 h 24 % 7.6 32.3 0963 17 1 2 x 36 3 h 16 % 9.9 54.2 0963 19 1 2 x 58 3 h 15 % 11 65 0963 38 1 Fixing accessories Cat. No. Set of 2 half clamps for fixing to 0965 93 1 Ø 49mm (1 1/2) or Ø 42mm (1 1/4) tube For fixing to Ø 60 mm (2 ) tube 0965 91 1 Set of 2 zinc-plated steel M8 ring bolts 0965 94 1 for suspending the unit Set of 2 aluminium brackets for 0965 97 1 fixing unit to flat surface. 316 stainless steel version 0965 90 1 Set of 2 aluminium hinged brackets for adjusting 0965 98 1 direction of luminaire when wall-mounted.. 316 stainless steel version 0965 74 1 Set of 2 zinc-plated steel brackets for 0965 96 1 quick fixing with one hand 316 stainless steel version 0965 89 1 Fall prevention fixing kit 0964 05 1 (1.20 m stainless steel chain) for M25 cable entry NEW For special options, please consult us : Other voltages Ø 38 mm bi-pin tubes Ø 38 mm bi-pin tubes specially designed for low temperatures Special protection of the diffuser against severe chemical attack Lens fall prevention fixing kit Dimensions of fixing accessories (see page 36-37) Installation and connection method (see page 38-39) Spare parts (see page 290) Pack Part number in bold : fast moving references

Zone 1 & 2-21 & 22 ATEX IEC EC II2 G/D EEx ed IIC or IIB T4 or T5 T = 85 C IP 66/67 IK 10 TECHNICAL DATA Zones : 1 and 2 and 21-22 Classification: According to CENELEC: Conforming to ATEX - 94/9 EC Directive and standards EN 50014-18-19 EC 0081 II 2 G : for gas EEx ed IIC* T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards. EC 0081 II 2 D T = + 85 C : for dust According to IEC: Conforming to IEC standards 60079-0/1/7 Ex eds IIC* T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards. DIP A21 TA = + 85 C * IIB with external buzzer Approvals : Approved type Fle CENELEC LCIE 98 ATEX 6004 IEC LCIE Ex 98.012 declaration of conformity No. 50201 Conforming to standards EN 60598-1 and IEC 60598-1 for luminaires Conforming to EN 50281-1-1 and IEC 61241-1-1 combustible dust Conforming to electromagnetic compatibility (EMC) standards - EN 55015 - EN 61547 Protection index : IP 66/67 according to EN 60529 and IEC 60529 Impact resistance : IK10 according to EN 50102 Operating temperature : - 20 C to + 55 C (18/36 W) ; -20 C to + 40 C (58 W) Dimensions (mm) : 18 W 217 400 700 785 1390 145 (2 x 18 W) Efficiency 85,1 % NF C 71-121 : 0,78 H + 0,08 T 58 W 36 W (2 x 36 W) Efficiency 80,5 % NF C 71-121 : 0,73 H + 0,07 T Product features/customer benefits 700 1690 (2 x 58 W) Efficiency 76,9 % NF C 71-121 : 0,70 H + 0,07 T - Positive safety switch : Safety Plus - Multi-parabolic reflector : increased efficiency - Ballast with plug in connectors : rapid error-free maintenance - Battery with connectors : rapid error-free maintenance - Opening system automatically protected : no over turning possible - Automatic tests with alarm and memory : easy maintenance NORMAL AND EMERGENCY BI-PIN FLUORESCENT LUMINAIRES Self-test with integrated alarm and memory visual indication Beep Beep Beep External audible indication Memory Mémorisation of tests Easy maintenance ATX : Safety Plus The LED indicates: - Charging status of battery and charger - Presence of mains power - State of the lamps - 3 long beeps every 35 min until the fault is repaired - 1 beep each time the unit is switched on confirms the unit is in good working order. 29 The microprocessor indicates the number of months remaining before the next annual 3-hour discharge test. - On-site maintenance - Plug-in with connector - Quick fixing - Integrated battery Battery discharge tests: 5-minute monthly test, 1-hour halfyear test, 3-hour yearly test. Results of the tests : LED on with steady light > battery present, charged > satisfactory charging current > mains supply present and connected. LED flashing > lamp fault. LED off > battery fault > no mains supply

30 110/127 V - 220/240 V mono-pin fluorescent luminaires for armoured or non-armoured cable increased safety 0965 50 Fluo 2 x 58W 0965 88 Fluo 2 x 36W 0969 05 Adaptator for Fa8 tube on Fa6 lampholder 0965 79 Fluo 2 x 18W 18/20, 36/40 and 58/65W fluorescent luminaires Ø 38 mm (20, 40 and 65 W) and Ø 26 mm (20, 36 and 58 W) mono-pin tubes with Fa 6 lampholders according to IEC 60061-1 Power supply via high frequency ballast depending on version : 99 to 140 V 110/127 V ± 10% AC/DC or 220/240 V~ ± 10%, 198 to 264 V Frequency: 50/60 Hz Instant start. Power factor 0.95 Pre-impregnated fibre glass reinforced polyester body Polycarbonate multi-parabolic hinged reflector Polycarbonate diffuser hinged to body Elastomer gasket High temperature internal wiring Anti-vibration lampholders with spring system Separate operation of the tubes: if one tube fails, the other tube remains lit Power supply to the unit cut off by positive safety switch which operates when diffuser is opened, for replacing tubes with mains power switched on Open and close using an Allen key or flat screwdriver (system automatically protects against over turning) IP 2X terminal strip cover for maintaining the ballast and lampholders without cutting off the main power supply Ballast fixed by screws, equipped with a fast connector Standard version for non-armoured cable Three threaded cable entries, 2 at one end and the third at the opposite end for M25 cable gland. Supplied with: One M25 polyamide cable gland (sealed Ø: 8 to 18.5 mm) Two M25 blanking plugs One 5 x 4 mm 2 flexible or 5 x 6mm 2 rigid connection terminal block maximum. Tube (W) Weight Volume Cat. No. Cat No. Pack not supplied (Kg) (dm 3 ) 110/127 V 220/240 V 2 x 18/20 7.54 54.2 0915 79 1 2 x 18/20 5.54 32.3 0965 79 1 2 x 36/40 7.88 54.2 0915 88 0965 88 1 2 x 58/65 9.00 65 0915 50 0965 50 1 Part number in bold : fast moving references Standard version for armoured cable Two M20 threaded cable entries with earth continuity plate for armoured cables at one end (cable gland not supplied) One clearance hole for M20 cable gland at the opposite end. Supplied with : Two blanking plugs and one M20 locknut One 5 x 4 mm 2 max. flexible or 5 x 6 mm 2 max. rigid connection terminal block Tube (W) Weight Volume Cat. No. Cat No. Pack not supplied (Kg) (dm 3 ) 110/127 V 220/240 V 2 x 18/20 7.54 54.2 0913 67 1 2 x 18/20 5.54 32.3 0963 67 1 2 x 36/40 7.88 54.2 0913 69 0963 69 1 2 x 58/65 9.00 65 0913 82 0963 82 1 Fixing accessories Cat. No. Set of 2 half clamps for fixing to 0965 93 1 Ø 49 mm (1 1/2) or Ø 42 mm (1 1/4) tube For fixing to Ø 60 mm (2 ) tube : 0965 91 1 Set of 2 zinc-plated steel M8 ring bolts 0965 94 1 for suspending the unit Set of 2 aluminium brackets for fixing 0965 97 1 on flat surface. 316 stainless steel version 0965 90 1 Set of 2 aluminium hinged brackets for adjusting 0965 98 1 direction of luminaire when wall-mounted. 316 stainless steel version 0965 74 1 Set of 2 zinc-plated steel brackets 0965 96 1 quick fixing with one hand 316 stainless steel version 0965 89 1 Fall prevention fixing kit 0964 06 1 (1.20 m stainless steel chain) for M20 cable entry Fall prevention fixing kit 0964 05 1 (1.20 m stainless steel chain) for M25 cable entry NEW Adaptor for Fa8 tube on Fa 6 lampholders 0969 05 1 For special options, please consult us: Electronic ballast 254 V 50/60 Hz + 6% - 10% Pole mounting and through wiring versions Single version (1 x 18 W - 1 x 36 W - 1 x 58 W) Special protection of the diffuser against severe chemical attack Lens fall prevention fixing kit Dimensions of fixing accessories (see page 36-37) Installation and connection method (see page 38-39) Spare parts (see page 290) Cable glands for armoured cable (see pages 252-262) Pack

31 TECHNICAL DATA Zones : 1 and 2, and 21-22 Classification : According to CENELEC : Conforming to ATEX - 94/9 EC directive and standards NP EN 50014-18-19 EC 0081 II 2 G: for gas EEx ed II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards EC 0081 II 2 D - T = + 85 C : for dust According to IEC : Conforming to IEC standards 60079-0/1/7 Ex ed II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards DIP A21 TA = + 85 C Approvals : Approved type Fle CENELEC LCIE 98 ATEX 6004 IEC LCIE Ex 98.012 declaration of conformity No. 50201 Conforming to standards EN 60598-1 and IEC 60598-1 for luminaires Conforming to EN 50281-1-1 and IEC 61241-1-1 combustible dust Conforming to electromagnetic compatibility (EMC) standards EN 55015 EN 61547 Zone 1 & 2-21 & 22 ATEX IEC EC II2 G/D EEx ed IIC T4 or T5 T = 85 C IP 66/67 IK 10 Dimensions (mm) : 18 W 36 W 217 400 700 785 1390 145 58 W 700 1690 Photometric data (photometry p. G62) polar curves for a 1000 lm flux, according to NF C 71-120 : longitudinal Luminaire symbol according to NF C 71-121 transverse (2 x 18 W) Efficiency 85,1 % NF C 71-121 : 0,78 H + 0,08 T Protection index : IP 66/67 according to EN 60529 and IEC 60529 Impact resistance: IK10 according to EN 50102 Operating temperature : - 20 C to + 55 C Anticorrosion treatment and climate protection : see page G50 Positive safety : Safety switch for opening luminaire, see glossary Anti-wiring-error connector (2 x 36 W) Efficiency 80,5 % NF C 71-121 : 0,73 H + 0,07 T (2 x 58 W) Efficiency 76,9 % NF C 71-121 : 0,70 H + 0,07 T Product features/customer benefits - Positive safety switch: Safety Plus - Multi-parabolic reflector: increased efficiency - Ballast with plug in connectors: rapid error-free maintenance - Opening system automatically protected : no over turning possible Data sheet available on request

32 220/240 V normal and emergency mono-pin fluorescent luminaires for armoured or non-armoured cable increased safety 0969 12 Fluo 2 x 58W 0969 11 Fluo 2 x 36W Charge indicating light 0969 10 Fluo 2 x 18W 18/20, 36/40 and 58/65W fluorescent luminaires Ø 38 mm (20, 40 and 65 W) and Ø 26 mm (18, 36 and 58 W) mono-pin tubes with Fa 6 lampholder according to IEC 60061-1 Frequency : 50/60 Hz Power supply : high frequency ballast 220/240V~ (+ 6%, - 10%) 198 to 264 V Instant start. Power factor 0.95 Battery voltage: 18W 6V 4A h - 36/58W 8.4V 4A h Pre-impregnated fibre glass reinforced polyester body Polycarbonate multi-parabolic hinged reflector Polycarbonate diffuser hinged to body High temperature internal wiring Elastomer gasket Anti-vibration lampholder with spring system Common power supply circuit to provide both normal lighting and emergency lighting Operation : mains power switched on, 2 tubes lit mains power switched off, 1 tube lit (battery backed) Power supply to the unit (mains supply and battery) cut off by two positive safety switches which operate when diffuser is opened, for replacing tubes with mains power switched on Green LED on when the installation is operating normally and off if there is a mains power supply failure or a battery fault Battery-back up tube identified with green mark Battery pack easily interchangeable on site, fixed by screws and equipped with a fast connector Ballast and converter fixed by screws, equipped with a fast connector Open and close using an Allen key or flat screwdriver (system automatically protects against over turning) Equipped with an IP 2 X terminal strip cover for maintenance of battery, ballast and lampholders with mains power switched on 18W version: one 4 x 4 mm 2 flexible or 4 x 6 mm 2 rigid connection terminal block max. including one earth terminal 36/58 W version: one 2 x 4 x 4 mm 2 flexible or 2 x 4 x 6mm 2 rigid connection terminal block max. including 2 earth terminals Standard version for non-armoured cable Three threaded cble entries for M25 cable glands. Supplied with: One M25 polyamide cable gland (sealed Ø: 8 to 18.5mm) Two M25 blanking plugs Tube (W) 1 tube Light Weight Volume Cat. No. Pack not supplied standby time output (Kg) (dm 3 ) 220/240V 2 x 18/20 3 h 29 % 7.6 32.3 0969 10 1 2 x 36/40 3 h 16 % 9.9 54.2 0969 11 1 2 x 58/65 3 h 11 % 11 65 0969 12 1 Standard version with earthing plate for armoured cable Two M20 threaded cable entries with earth continuity plate at one end (cable gland not supplied) One clearance hole for M20 cable gland at the opposite end Supplied with: Two M20 blanking plugs and one M20 locknut Tube (W) 1 tube Light Weight Volume Cat. No. Pack not supplied standby time output (Kg) (dm 3 ) 220/240 V 2 x 18/20 3 hrs 29% 7.6 32.3 0969 20 1 2 x 36/40 3 hrs 16% 9.9 54.2 0969 21 1 2 x 58/65 3 hrs 11% 9 65 0969 22 1 Fixing accessories Cat. No. Set of 2 half clamps for fixing to 0965 93 1 Ø 49 mm (1 1/2) or Ø 42 mm (1 1/4) tube For fixing to Ø 60 mm (2 ) tube 0965 91 1 Set of 2 zinc-plated steel M8 ring bolts 0965 94 1 for suspending the unit Set of 2 aluminium brackets for fixing 0965 97 1 unit on flat surface. 316 stainless steel version 0965 90 1 Set of 2 aluminium hinged brackets for adjusting 0965 98 1 direction of luminaire when wall-mounted. 316 stainless steel version 0965 74 1 Set of 2 zinc-plated steel brackets for 0965 96 1 quick fixing with one hand 316 stainless steel version 0965 89 1 Fall prevention fixing kit (1.20 m stainless steel chain) for M20 cable entry 0964 06 1 Fall prevention fixing kit (1.20 m stainless steel chain) for M25 cable entry 0964 05 1 NEW Adaptor for Fa8 tube 0969 05 1 For special options, please consult us: 1,5 hour emergency duration External battery Other voltages Special protection of the diffuser against severe chemical attack Lens fall prevention fixing kit Dimensions of fixing accessories (see page 36-37) Installation and connection method (see page 38-39) Spare parts (see page 290 ) Cable glands for armoured cable (see pages 252-262) Pack Part number in bold : fast moving references

33 TECHNICAL DATA Zones : 1 and 2, and 21-22 Classification : According to CENELEC : Conforming to ATEX - 94/9 EC Directive and standards EN 50014-18-19-28 EC 0081 II 2 G : for gas EEx edm II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards. EC 0081 II 2 D - T = + 85 C : for dust According to IEC : Conforming to IEC standards 60079-0/1/7/18 Ex edm II C T4 or T5 to Ta max. + 40 C horizontal position, lighting facing downwards. DIP A21 TA = + 85 C Approvals : Approved type Fle CENELEC LCIE 98 ATEX 6004 IEC LCIE Ex 98.012 declaration of conformity No. 50201 Conforming to standards EN 60598-1 and IEC 60598-1 for luminaires Conforming to standards EN 50281-1-1 and IEC 612241-1-1 combustible dust Conforming to electromagnetic compatibility (EMC) standards EN 55015 and EN 61547 Zone 1 & 2-21 & 22 ATEX IEC EC II2 G/D EEx edm IIC T4 or T5 T = 85 C IP 66/67 IK 10 Dimensions (mm) : Standard/through-wiring version 18 W 36 W 217 400 700 785 1390 145 58 W 700 1690 Photometric data (photometry p. G62) polar curves for a 1000 lm flux, according to NF C 71-120: longitudinal Luminaire symbol according to NF C 71-121 transverse (2 x 18 W) Efficiency 85,1 % NF C 71-121 : 0,78 H + 0,08 T Protection index : IP 66/67 according to EN 60529 and IEC 60529 Impact resistance : IK10 according to EN 50102 Operating temperature : 20 C to + 55 C Anticorrosion treatment and climate protection : see page G50 Positive safety : Safety switch for opening contacts Anti-wiring-error connector (2 x 36 W) Efficiency 80,5 % NF C 71-121 : 0,73 H + 0,07 T (2 x 58 W) Efficiency 76,9 % NF C 71-121 : 0,70 H + 0,07 T Product features/customer benefits - Positive safety switch: Safety Plus - Multi-parabolic reflector: increased efficiency - Ballast with plug in connectors: rapid error-free maintenance - Ballast with connectors: rapid error-free maintenance - System automatically protected : no over turning possible Data sheet available on request

34 110/127 V - 220/240 V level gauge light fitting for non-armoured cable increased safety 0965 32 level gauge light fitting 1 x 36W Installation in vertical position 18, 36 and 58 W level gauge light fitting Ø 26 mm tube, standard G13 caps Frequency : 50/60 Hz Power supply via high frequency ballast according to model: 110/127 V ± 10% AC/DC or 220/240 V~ ± 10%, 198 to 264 V Instant start. Power factor 0.95 Pre-impregnated fibre glass reinforced polyester body Polycarbonate diffuser hinged to body Lighting concentrated on level indicator High temperature internal wiring Elastomer gasket Anti-vibration lampholders with spring system Power supply to the unit cut off by positive safety switch which operates when diffuser is opened, for replacing tube with mains power switched on Open and close using an Allen key or flat screwdriver (system automatically protects against over turning) IP 2X terminal strip cover for maintaining the ballast and lampholders without cutting off the main power supply Ballast fixed by screws, equipped with a fast connector Level gauge light version Three threaded cable entries, 2 at one end and the third at the opposite end for M25 cable gland. Supplied with : One M25 polyamide cable gland (sealed Ø 8 to 18.5 mm) Two M25 blanking plugs One 5 x 4 mm 2 max. flexible or 5 x 6 mm 2 max. rigid connection terminal block Fixing accessories Cat. No. Set of 2 half clamps for fixing to 0965 93 1 Ø 49 mm (1 1/2) or Ø 42 mm (1 1/4) tube For fixing to Ø 60 mm (2 ) tube 0965 91 1 Set of 2 aluminium brackets for 0965 97 1 fixing unit to flat surface 316 stainless steel version 0965 90 1 Set of 2 aluminium hinged brackets for adjusting 0965 98 1 direction of luminaire when wall-mounted. 316 stainless steel version 0965 74 1 Set of 2 zinc-plated steel brackets for 0965 96 1 quick fixing with one hand 316 stainless steel version 0965 89 1 NEW For special options, please consult us: Ø 38 mm standard or bi-pin tubes specially designed for low temperatures Special protection of the diffuser against severe chemical attack Dimensions of fixing accessories (see page 36-37) Installation and connection method (see page 38-39) Spare parts (see page 290) Timer switch (see page 211) Pack Tube (W) Weight Volume Cat. No. Cat No. Pack not supplied (Kg) (dm 3 ) 110/127 V 220/240 V 1 x 18 5.5 32.3 0915 31 0965 31 1 1 x 36 7.9 54.2 0915 32 0965 32 1 1 x 58 9 65 0915 33 0965 33 1 Part number in bold : fast moving references

35 TECHNICAL DATA Zones : 1 and 2 and 21-22 Classification : According to CENELEC: Conforming to ATEX - 94/9 EC Directive and standards EN 50014-18-19 EC 0081 II 2 G : for gas EEx ed II C T4 EC 0081 II 2 D - T = + 85 C: for dust According to IEC : Conforming to IEC standards 60079-0/1/7 Ex ed II C T4 DIP A21 TA = + 85 C Approvals : Approved type Fle CENELEC LCIE 98 ATEX 6004 IEC LCIE Ex 98.012 declaration of conformity No. 50201 Conforming to standards EN 60598-1and IEC 60598-1 for luminaires Conforming to standards EN 50281-1-1 and IEC 61241-1-1 combustible dust Conforming to electromagnetic compatibility (EMC) standards - EN 55015 - EN 61547 Protection index : IP 66/67 according to EN 60529 and IEC 60529 Impact resistance : IK10 according to EN 50102 Operating temperature : 20 C to + 55 C Anticorrosion treatment and climate protection : see page G50 Zone 1 & 2-21 & 22 ATEX IEC EC II2 G/D EEx ed IIC T4 or T5 T = 85 C IP 66/67 IK 10 Dimensions (mm) : 36W 58W 700 1390 700 1690 145 400 785 217 18W Positive safety plus : Safety switch for opening luminaire, see glossary Anti-wiring-error connector Installation Gauge Tank Product features/customer benefits - Positive safety switch : Safety Plus - Multi-parabolic reflector : increased efficiency - Ballast with plug in connectors : rapid error-free maintenance - Opening system automatically protected : no over turning possible - Concentrated beam : improved legibility Gauge lit on its full length in normal position of the luminaire Data sheet available on request

36 Dimensions of fixing accessories Quick fixing brackets Zinc plated steel or stainless steel 0965 96 0965 89 Ø 9 30 25 49 8.5 4 64 Fixing brackets for flat surface (painted aluminium alloy or stainless steel) 0965 97 0965 90 232 200 9.5 13 38 14.5 32 Set of pole claps (1 1/4 to 2 tube) (zinc-plated steel) 0965 93 0965 91 75 Ø 49 95 pour 1"1/4 / 1"1/2 30 14 1" 1/4 ou 1" 1/2 ou 84 pour 2" 14 85 Ø 60 2"

Ø 42 Dimensions of fixing accessories 37 Set of 2 ring blots (zinc-plated steel) 0965 94 Ø 20 36 Ø 8 15 M 8x1.25 Set of 2 hinged brackets (painted aluminium alloy or stainless steel) 0965 98 0965 74 5.5 77 32 18 82 30 30 100 132 90 30 14.5 41 13 M 8X1.25 9.5 42 mm diam galvanized steel wall mounting pole 0965 95 152 128 12 Ø 20 5 75 140 200 430 Ø 10.5