SUN INGECON. Box 220 / 275 / 300 / 320 / 345 / 360 Vac. M220 / M275 / M300 / M320 / M345 / M360 Outdoor.

Similar documents
Power Station Photovoltaic Energy

20 and 40-feet MV turnkey solutions, customised up to 5400 kva with Outdoor Inverters

We recharge the energy that moves us

Power Station Photovoltaic Energy

Ingecon Sun String Control. Installation manual

40-feet MV turnkey solution, customised up to 4920 kva

ABB central inverters PVS to 1000 kw

ABB central inverters PVS to 1000 kw

PTI/PTO Hybrid Electrical Drives

ABB central inverters PVS to 2091 kva

Solar Energy Solutions Product Catalogue

ABB central inverters ULTRA-750/1100/ kW to 1560kW

ABB central inverters PVS to 2000 kva

Clay Preshaw RE: HPE CM: Beryl Solar Farm - Amended Conditions IS B Series family at 1500 Vdc_v2.pdf; SW103_Constraints_

Photovoltaic Solar Energy. A complete inverter family for grid-connected and off-grid PV plants

INGECON SUN PowerMax B SERIES. A new generation of central photovoltaic inverters

Pre-announcement. Transformerless Solar Inverters

SOLAR2PS 500 / 630 / 750 kw Three Phase Solar PV Inverter

String Inverter (SUN KTL-A)

Features MICRO-0.25-I MICRO-0.3-I PRODUCTS PANEL

ELECTRIC MOBILITY. A charging solution for each specific need

DECLARATION OF CONFORMITY

SOLAR ENERGY KIT MODEL: SEM-CS3000

Maximize your ROI. Conext CL-60 String Inverter. The ideal solution for decentralized power plants and commercial rooftops

INSTALACIONES Y MONTAJES, S.A.

3 Phase Power Systems - Designed for Canada

A flexible and efficient residential solar solution. Conext RL single-phase grid-tie inverter

Power Conversion System The Best Technology for your photovoltaic and storage system

INGEDRIVE E3-Ship Highly-Efficient & Compact Integrated Power System for Electrically propelled vessels

FINHRM FINHRM5 FINHRMA FINHRMAC

SolarMax MT A series A reliable solution for commercial PV applications

APS-PV-Series 1000 V DC

ABB micro inverter system MICRO-0.25/0.3/0.3HV-I-OUTD 0.25kW to 0.3kW

Jorge Álvarez, PM Solar, Abril 15 th - Santiago. ABB Solar Central lnverters (PMGD)

Green Inverters from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters.

SolarMax MT series The all-rounder for trade and industry

Sunny Tripower CORE1.

photovoltaikforum.com

TripleLynx Inverter Range MAKING MODERN LIVING POSSIBLE. The benchmark solar inverter from Danfoss 3 phase Transformerless 8, 10, 12.

GS1500i V central solar inverter. INDUSTRIAL SOLUTIONS

ABB micro inverter system MICRO-0.25/0.3/0.3HV-I-OUTD 0.25kW to 0.3kW

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

SolarMax P series The power package for residential solar plants

APS-ES-Series 1000 V DC

E l ower. Inverters for renewables RENEWABLE SOURCES. elettronica di otenza

SAJ Solar Inverter. Sununo Plus 1K/1.5K BENEFITS. Smart and Easy to Use. Flexible and Efficient. Safe and Reliable. Convenient Installation

RPS TL-UL System. Solutions for the North American Solar Market

MTPi2000C - 80 KW (RANGE)

HYBRID INVERTERS for Energy Storage Systems. Renewable Energy on demand

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

New Central Grid-tied PV Inverters. 500kW/1MW 3-level T-type modular inverters 1MW/2MW PV power containers

PV Inverters. for grid connection Catalogue. APV Solar Inverters. Rev EN

Power conversion systems for energy storage. Engineering that stores

SolarMax MT series. The power pack for maximum yields.

ABB string inverters PVI-3.0/3.6/4.2-TL-OUTD 3 to 4.2 kw

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

ABB string inverters PVI-3.8/4.6-I-OUTD 3.8 to 4.6 kw

Distribution division. Solar Photovoltaic Catalogue. Premier Plaan. Smart solutions for the solar energy sector around the world

Station Identification. Results. PV System Specifications. Energy Specifications. Solar Radiation (kwh/m 2 /day) Energy Value ($) AC Energy (kwh)

SolarMax 330TS-SV. The all-round solution for large-scale PV installations.

AC MODULE P72PCS-300W

Schneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant

INVERTER. MECHANICAL DATA Steel with powder paint Dimension (mm) 527 x 228 x 190 Net Weight (kgs) 18 STANDAR. Cont output power at 20ºC. Cos φ 0.

Re-defining the utility-scale inverter

HUAWEI Smart PV Plant Solutions

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

Greater reliability and flexibility for large solar installations. Conext Core XC-NA series central inverters

500 / 630 / 720 / 760 / 800 / 850 / 900

Technical specifications

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

ABB - DMPC PG Solar, Nov 2016 ABB: a leading company in solar The most comprehensive value proposition

Integrated Marine Solutions

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

MASTERYS IP+ 10 to 80 kva

Retrofit to Single phase / Three phase PV system Micro-grid, UPS, Peak shift, Pure off-grid retrofitting etc multi-working

ABB solar inverters Product portfolio

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Don't let the shadows of yesterday hide the sunshine of tomorrow Nandina Morris

ahead of time Voltage Stabilisers

SMA COMMERCIAL PRODUCTS SUNNY TRIPOWER CORE1. Stands on its own. Up to 60 % faster installation for commercial PV systems

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS 1.2 to 5.0 kw

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS-Q 1.2 to 5.0 kw

SolarMax 50TS/80TS/100TS/300TS. Ready for the future.

Application. Battery. Public Grid GS HYBRID INVERTER

MAX310 BEESMART SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY Apparent Power Control (APC)

CONERGY CIS 1200 Manufactured By Bosch

SolarMax S series (Australia) Maximising solar plant yields can be so easy.

Guidelines for the Design of Residential and Community Level Storage Systems Combined with Photovoltaics (PV)

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

Conext CL. The ideal solution for commercial buildings carports, and decentralized power plants. solar.schneider-electric.com

Residential Energy Storage System SH5K PV ESS

Microinverters: an introduction May 2013

Green Inverters from

Power Conversion System for ESS 100 kw to 30 MW Bi-directional Inverters

MERU Solar Off-Grid Inverters

Voice of GM. Company Profile. Certificates. Product Advantages. Technical Parameters. Service. General Manager GoodWe Power Supply Technology Co.

Growatt Storage Plus. Marketing Dept. Aug 2014

RENEWABLE ENERGY SOLUTION

Catch Eco Range : Technical Specification Sheet

Transcription:

Box 220 / 275 / 300 / 320 / 345 / 360 Vac M220 / M275 / M300 / M320 / M345 / M360 Outdoor INVERTERS FOR OUTDOOR INSTALLATION, IDEAL FOR MULTI-MEGAWATT PV PLANTS Designed for outdoor installation Suitable for outdoor installation thanks to its compact and weatherproof enclosure and to the extended operative temperature range. Maximum efficiency with independent DC stages Modular transformerless design to considerably increase the efficiency of the PV plant. Independent power stages equipped with advanced maximum power point tracking system (MPPT) *. Suitable to multi-megawatt installations with direct connection to a MV transformer. Ease of maintenance Independent operation of the power stages to achieve the maximum efficiency and a useful life of more than 20 years. Modular power stages easy to replace. Compliance with the most demanding standards and regulations The Ingecon Sun Box inverters support all the functions (active power control, reactive power control, voltage dips, etc.) and offer all DC/AC protection devices required by the most demanding standards and regulations. Standard 5 years warranty, extendable up to 25 years on request * The PV array strings configuration of MPPT modules connected to the same transformer must be as much as possible similar one to each other. OPTIONAL ACCESSORIES MAIN FEATURES LVFRT (Low Voltage Fault Ride Through) kit for voltage dips insensitivity. High voltage grid connection kit. Night power supply kit. 1000 V DC option. Communication via Ethernet or Bluetooth. Ethernet or GSM/GPRS board for remote communication. Ingecon Sun ComBox device for remote communication and meteorological variables measurement. PV array strings current monitoring by means of Ingecon Sun String Control device. Robust and weatherproof design with IP54 protection class for outdoor installation. Maximum efficiency up to 98.8 %. Ingeteam Long Life System increasing the useful life of the inverter to more than 20 years by means of polypropylene capacitors and interference inductances reduction. Ingeteam "Fire Safety System" by means of DC contactors for automatic PV array disconnection in case of fire. Reactive power control up to +/- 35% of rated power with active output power 5%. Reduced production losses in case of single power stage failure. Low maintenance costs: same spare parts kit for all independent modules. Ease of maintenance thanks to the modular power stages and to the built-in diagnostic systems. Available with NAC configuration for space reduction and costs optimization. Embedded LCD display and keypad. Embedded RS485 interface for devices interconnection. Internal datalogger for up to 3 months data storage. Ingecon Sun Manager software for parameter display and data recording. Ingecon Web Monitor web portal for PV plants remote access. Compliance with the main medium and high voltage grid standards and regulations. 5 years warranty, extendable up to 25 years on request. www.ingeteam.it italia.energy@ingeteam.com

Input 250 M220 Outdoor 375 M220 Outdoor 500 M220 Outdoor Recommended PV array power range (1) 283-325 kwp 424-488 kwp 566-650 kwp MPPT input DC voltage range 405-820 V 405-820 V 405-820 V Maximum Input DC voltage (2) 920 V 920 V 920 V Maximum input DC current 800 A 1200 A 1600 A Number of DC inputs 8 12 16 DC connection type Number of power stages 2 3 4 Number of independent MPPT 2 3 4 Input Protection DC switch Class II DC surge arresters (for each power stage) DC breaker with door control (for each power stage) DC fuses, DC contactor for disconnection from PV array, DC insulation monitor with alarm (for each power stage) Output AC rated power (3) 275 kw 412.5 kw 550 kw AC maximum current 736 A 1104 A 1472 A AC rated voltage 220 V IT system 220 V IT system 220 V IT system Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Cos Phi (4) 1 1 1 Adjustable Cos Phi ± 0.9 at Pnom ± 0.9 at Pnom ± 0.9 at Pnom THD (Total Harmonic Distortion) (4) < 3 % < 3 % < 3 % AC connection type Output Protection AC switch Anti-islanding protection Class II AC surge arresters (for each power stage) AC thermal-magnetic switch with door control (for each power stage) Yes, with automatic disconnection (for each power stage) AC short circuits and overload (for each power stage) Performance Maximum efficiency 98.1 % 98.1 % 98.1 % European efficiency / CEC 97.7 % / 97.3 % 97.7 % / 97.3 % 97.7 % / 97.3 % Stand-by consumption (5) 60 W 90 W 120 W Night-time consumption < 5 W < 5 W < 5 W General Information Ambient temperature range -20 C to +65 C -20 C to +65 C -20 C to +65 C Relative humidity 0 to 95 % 0 to 95 % 0 to 95 % Protection class IP 54 IP 54 IP 54 Maximum operating altitude (6) Cooling system 3000 m a.s.l. Air forced with temperature control (400 V three phase + neutral power supply) Required air cooling flow 4000 m 3 /h (fans power 1590 W) 8000 m 3 /h (fans power 2770 W) 8000 m 3 /h (fans power 3180 W) Noise emission Marking < 55 db (A) at 4 m and < 67 db (A) at 1 m with fans working at maximum power CE Safety and EMC standards EN 50178, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC part 15 Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI 11-20 V1, CEI 0-16, Allegati A68 e A70 TERNA, CEI 0-21, IEEE1547, Arrêté 23-04-08 Size and Weight Size (WxDxH) 2987 x 1067 x 2681 mm 3587 x 1067 x 2681 mm 4209 x 1067 x 2681 mm Weight 2080 Kg 2780 Kg. 3480 Kg. Notes: (1) Depending on the PV modules type and geographical location. (2) 1000 Vdc optional. It must not be exceeded under any circumstances. Consider the voltage increase of the VOC at low temperatures. (3) AC power up to 40 C of ambient temperature. For each C of increase up to 50 C the output power will be reduced of 1.8 %. (4) For Pout > 25% of the rated power and voltage in accordance with IEC 61000-3-4. (5) Consumption from PV field. (6) Rated AC power up to 1200 m a.s.l. without derating. For higher altitudes, please contact Ingeteam.

Efficiency 250 M220 Outdoor 375 M220 Outdoor 500 M220 Outdoor Maximum Efficiency 98,1 % 98,1 % 98,1 % European Efficiency / CEC 97.7 % / 97.3 % 97.7 % / 97.3 % 97.7 % / 97.3 % Efficiency @ Poutput = 5% rated power 95,4 % 95,4 % 95,4 % Efficiency @ Poutput = 10% rated power 97,1 % 97,1 % 97,1 % Efficiency @ Poutput = 20% rated power 97,9 % 97,9 % 97,9 % Efficiency @ Poutput = 30% rated power 98,1 % 98,1 % 98,1 % Efficiency @ Poutput = 50% rated power 98,0 % 98,0 % 98,0 % Efficiency @ Poutput = 100% rated power 97,2 % 97,2 % 97,2 % Efficiency Curve Efficiency (%) 100,00 98,00 96,00 94,00 92,00 90,00 88,00 86,00 84,00 82,00 Ingecon Sun Box 500 M220 Vdc = 500 V 80,00 0 10 20 30 40 50 60 70 80 90 100 P/Pnom (%) Ingecon Sun Box 500 M220 Outdoor MAIN AC POWER CONNECTION Size (WxDxH) and Weight Box 250 M220 Outdoor Box 375 M220 Outdoor Box 500 M220 Outdoor 2987 x 1067 x 2681 mm 3587 x 1067 x 2681 mm 4209 x 1067 x 2681 mm 2080 Kg 2780 Kg 3480 Kg

Input 315 M275 Outdoor 500 M275 Outdoor 630 M275 Outdoor Recommended PV array power range (1) 354-410 kwp 531-650 kwp 709-819 kwp MPPT input DC voltage range 445-820 V 445-820 V 445-820 V Maximum Input DC voltage (2) 920 V 920 V 920 V Maximum input DC current 800 A 1200 A 1600 A Number of DC inputs 8 12 16 DC connection type Number of power stages 2 3 4 Number of independent MPPT 2 3 4 Input Protection DC switch Class II DC surge arresters (for each power stage) DC breaker with door control (for each power stage) DC fuses, DC contactor for disconnection from PV array, DC insulation monitor with alarm (for each power stage) Output AC rated power (3) 346.5 kw 519,75 kw 693 kw AC maximum current 736 A 1104 A 1472 A AC rated voltage 275 V IT system 275 V IT sytem 275 V IT system Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Cos Phi (4) 1 1 1 Adjustable Cos Phi ± 0.9 a Pnom ± 0.9 a Pnom ± 0.9 a Pnom THD (Total Harmonic Distortion) (4) < 3 % < 3 % < 3 % AC connection type Output Protection AC switch Anti-islanding protection Class II AC surge arresters (for each power stage) AC thermal-magnetic switch with door control (for each power stage) Yes, with automatic disconnection (for each power stage) AC short circuits and overload (for each power stage) Performance Maximum efficiency 98.5 % 98.5 % 98.5 % European efficiency / CEC 98.2 % / 97.7 % 98.2 % / 97.7 % 98.2 % / 97.7 % Stand-by consumption (5) 60 W 90 W 120 W Night-time consumption < 5 W < 5 W < 5 W General Information Ambient temperature range -20 C to +65 C -20 C to +65 C -20 C to +65 C Relative humidity 0 to 95 % 0 to 95 % 0 to 95 % Protection class IP 54 IP 54 IP 54 Maximum operating altitude (6) Cooling system 3000 m a.s.l. Air forced with temperature control (400 V three phase + neutral power supply) Required air cooling flow 4000 m 3 /h (fans power 1590 W) 8000 m 3 /h (fans power 2770 W) 8000 m 3 /h (fans power 3180 W) Noise emission Marking < 55 db (A) at 4 m and < 67 db (A) at 1 m with fans working at maximum power CE Safety and EMC standards EN 50178, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC part 15 Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI 11-20 V1, CEI 0-16, Allegati A68 e A70 TERNA, CEI 0-21, IEEE1547, Arrêté 23-04-08 Size and Weight Size (WxDxH) 2987 x 1067 x 2681 mm 3587 x 1067 x 2681 mm 4209 x 1067 x 2681 mm Weight 2080 Kg 2780 Kg. 3480 Kg. Notes: (1) Depending on the PV modules type and geographical location. (2) 1000 Vdc optional. It must not be exceeded under any circumstances. Consider the voltage increase of the VOC at low temperatures. (3) AC power up to 40 C of ambient temperature. For each C of increase up to 50 C the output power will be reduced of 1.8 %. (4) For Pout > 25% of the rated power and voltage in accordance with IEC 61000-3-4. (5) Consumption from PV field. (6) Rated AC power up to 1200 m a.s.l. without derating. For higher altitudes, please contact Ingeteam.

Efficiency 315 M275 Outdoor 500 M275 Outdoor 630 M275 Outdoor Maximum Efficiency 98.5 % 98.5 % 98.5 % European Efficiency / CEC 98.2 % / 97.7 % 98.2 % / 97.7 % 98.2 % / 97.7 % Efficiency @ Poutput = 5% rated power 96.3% 96.3% 96.3% Efficiency @ Poutput = 10% rated power 97.7% 97.7% 97.7% Efficiency @ Poutput = 20% rated power 98.3% 98.3% 98.3% Efficiency @ Poutput = 30% rated power 98.5% 98.5% 98.5% Efficiency @ Poutput = 50% rated power 98.4% 98.4% 98.4% Efficiency @ Poutput = 100% rated power 97.7% 97.7% 97.7% Efficiency Curve Efficiency (%) Ingecon Sun Box 630 M275 Vdc = 550 V 100,00 98,00 96,00 94,00 92,00 90,00 88,00 86,00 84,00 82,00 80,00 0 10 20 30 40 50 60 70 80 90 100 P/Pnom (%) Ingecon Sun Box 630 M275 Outdoor MAIN AC POWER CONNECTION Size (WxDxH) and Weight Box 315 M275 Outdoor Box 500 M275 Outdoor Box 630 M275 Outdoor 2987 x 1067 x 2681 mm 3587 x 1067 x 2681 mm 4209 x 1067 x 2681 mm 2080 Kg 2780 Kg 3480 Kg

Input 345 M300 Outdoor 515 M300 Outdoor 690 M300 Outdoor Recommended PV array power range (1) 386-447 kwp 579-671 kwp 772-894 kwp MPPT input DC voltage range 456-820 V 456-820 V 456-820 V Maximum Input DC voltage (2) 920 V 920 V 920 V Maximum input DC current 800 A 1200 A 1600 A Number of DC inputs 8 12 16 DC connection type Number of power stages 2 3 4 Number of independent MPPT 2 3 4 Input Protection DC switch Class II DC surge arresters (for each power stage) DC breaker with door control (for each power stage) DC fuses, DC contactor for disconnection from PV array, DC insulation monitor with alarm (for each power stage) Output AC rated power (3) 378.5 kw 568 kw 757 kw AC maximum current 736 A 1104 A 1472 A AC rated voltage 300 V IT system 300 V IT system 300 V IT system Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Cos Phi (4) 1 1 1 Adjustable Cos Phi ± 0.9 at Pnom ± 0.9 at Pnom ± 0.9 at Pnom THD (Total Harmonic Distortion) (4) < 3 % < 3 % < 3 % AC connection type Output Protection AC switch Anti-islanding protection Class II AC surge arresters (for each power stage) AC thermal-magnetic switch with door control (for each power stage) Yes, with automatic disconnection (for each power stage) AC short circuits and overload (for each power stage) Performance Maximum efficiency 98.6 % 98.6 % 98.6 % European efficiency / CEC 98.3 % / 97.8 % 98.3 % / 97.8 % 98.3 % / 97.8 % Stand-by consumption (5) 60 W 90 W 120 W Night-time consumption < 5 W < 5 W < 5 W General Information Ambient temperature range -20 C to +65 C -20 C to +65 C -20 C to +65 C Relative humidity 0 to 95 % 0 to 95 % 0 to 95 % Protection class IP 54 IP 54 IP 54 Maximum operating altitude (6) Cooling system 3000 m a.s.l. Air forced with temperature control (400 V three phase + neutral power supply) Required air cooling flow 4000 m 3 /h (fans power 1590 W) 8000 m 3 /h (fans power 2770 W) 8000 m 3 /h (fans power 3180 W) Noise emission Marking < 55 db (A) at 4 m and < 67 db (A) at 1 m with fans working at maximum power CE Safety and EMC standards EN 50178, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC part 15 Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI 11-20 V1, CEI 0-16, Allegati A68 e A70 TERNA, CEI 0-21, IEEE1547, Arrêté 23-04-08 Size and Weight Size (WxDxH) 2987 x 1067 x 2681 mm 3587 x 1067 x 2681 mm 4209 x 1067 x 2681 mm Weight 2080 Kg 2780 Kg. 3480 Kg. Notes: (1) Depending on the PV modules type and geographical location. (2) 1000 Vdc optional. It must not be exceeded under any circumstances. Consider the voltage increase of the VOC at low temperatures. (3) AC power up to 40 C of ambient temperature. For each C of increase up to 50 C the output power will be reduced of 1.8 %. To achieve the maximum output power in any operating conditions it is recommended a strings configuration with VOC close to 920 V. (4) For Pout > 25% of the rated power and voltage in accordance with IEC 61000-3-4. (5) Consumption from PV field. (6) Rated AC power up to 1200 m a.s.l. without derating. For higher altitudes, please contact Ingeteam.

Efficiency 345 M300 Outdoor 515 M300 Outdoor 690 M300 Outdoor Maximum Efficiency 98.6 % 98.6 % 98.6 % European Efficiency / CEC 98.3 % / 97.8 % 98.3 % / 97.8 % 98.3 % / 97.8 % Efficiency @ Poutput = 5% rated power 96.6 % 96.6 % 96.6 % Efficiency @ Poutput = 10% rated power 97.9 % 97.9 % 97.9 % Efficiency @ Poutput = 20% rated power 98.4 % 98.4 % 98.4 % Efficiency @ Poutput = 30% rated power 98.6 % 98.6 % 98.6 % Efficiency @ Poutput = 50% rated power 98.5 % 98.5 % 98.5 % Efficiency @ Poutput = 100% rated power 98.0 % 98.0 % 98.0 % Efficiency Curve Efficiency (%) Ingecon Sun Box 690 M300 Vdc = 550 V 100,00 98,00 96,00 94,00 92,00 90,00 88,00 86,00 84,00 82,00 80,00 0 10 20 30 40 50 60 70 80 90 100 P/Pnom (%) Ingecon Sun Box 690 M300 Outdoor MAIN AC POWER CONNECTION Size (WxDxH) and Weight Box 345 X300 Outdoor Box 515 X300 Outdoor Box 690 X300 Outdoor 2987 x 1067 x 2681 mm 3587 x 1067 x 2681 mm 4209 x 1067 x 2681 mm 2080 Kg 2780 Kg 3480 Kg

Input 365 M320 Outdoor 550 M320 Outdoor 730 M320 Outdoor Recommended PV array power range (1) 409-475 kwp 617-715 kwp 819-949 kwp MPPT input DC voltage range 468-820 V 468-820 V 468-820 V Maximum Input DC voltage (2) 920 V 920 V 920 V Maximum input DC current 800 A 1200 A 1600 A Number of DC inputs 8 12 16 DC connection type Number of power stages 2 3 4 Number of independent MPPT 2 3 4 Input Protection DC switch Class II DC surge arresters (for each power stage) DC breaker with door control (for each power stage) DC fuses, DC contactor for disconnection from PV array, DC insulation monitor with alarm (for each power stage) Output AC rated power (3) 401,5 kw 602 kw 803 kw AC maximum current 736 A 1104 A 1472 A AC rated voltage 320 V IT system 320 V IT system 320 V IT system Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Cos Phi (4) 1 1 1 Adjustable Cos Phi ± 0.9 at Pnom ± 0.9 at Pnom ± 0.9 at Pnom THD (Total Harmonic Distortion) (4) < 3 % < 3 % < 3 % AC connection type Output Protection AC switch Anti-islanding protection Class II AC surge arresters (for each power stage) AC thermal-magnetic switch with door control (for each power stage) Yes, with automatic disconnection (for each power stage) AC short circuits and overload (for each power stage) Performance Maximum efficiency 98.7 % 98.7 % 98.7 % European efficiency / CEC 98.4 % / 97.9 % 98.4 % / 97.9 % 98.4 % / 97.9 % Stand-by consumption (5) 60 W 90 W 120 W Night-time consumption < 5 W < 5 W < 5 W General Information Ambient temperature range -20 C to +65 C -20 C to +65 C -20 C to +65 C Relative humidity 0 to 95 % 0 to 95 % 0 to 95 % Protection class IP 54 IP 54 IP 54 Maximum operating altitude (6) Cooling system 3000 m a.s.l. Air forced with temperature control (400 V three phase + neutral power supply) Required air cooling flow 4000 m 3 /h (fans power 1590 W) 8000 m 3 /h (fans power 2770 W) 8000 m 3 /h (fans power 3180 W) Noise emission Marking < 55 db (A) at 4 m and < 67 db (A) at 1 m with fans working at maximum power CE Safety and EMC standards EN 50178, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC part 15 Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI 11-20 V1, CEI 0-16, Allegati A68 e A70 TERNA, CEI 0-21, IEEE1547, Arrêté 23-04-08 Size and Weight Size (WxDxH) 2987 x 1067 x 2681 mm 3587 x 1067 x 2681 mm 4209 x 1067 x 2681 mm Weight 2080 Kg 2780 Kg. 3480 Kg. Notes: (1) Depending on the PV modules type and geographical location. (2) 1000 Vdc optional. It must not be exceeded under any circumstances. Consider the voltage increase of the VOC at low temperatures. (3) AC power up to 40 C of ambient temperature. For each C of increase up to 50 C the output power will be reduced of 1.8 %. To achieve the maximum output power in any operating conditions it is recommended a strings configuration with VOC close to 920 V. (4) For Pout > 25% of the rated power and voltage in accordance with IEC 61000-3-4. (5) Consumption from PV field. (6) Rated AC power up to 1200 m a.s.l. without derating. For higher altitudes, please contact Ingeteam.

Efficiency 365 M320 Outdoor 550 M320 Outdoor 730 M320 Outdoor Maximum Efficiency 98.7 % 98.7 % 98.7 % European Efficiency / CEC 98.4 % / 97.9 % 98.4 % / 97.9 % 98.4 % / 97.9 % Efficiency @ Poutput = 5% rated power 96.8 % 96.8 % 96.8 % Efficiency @ Poutput = 10% rated power 98.0 % 98.0 % 98.0 % Efficiency @ Poutput = 20% rated power 98.5 % 98.5 % 98.5 % Efficiency @ Poutput = 30% rated power 98.7 % 98.7 % 98.7 % Efficiency @ Poutput = 50% rated power 98.6 % 98.6 % 98.6 % Efficiency @ Poutput = 100% rated power 98.1 % 98.1 % 98.1 % Efficiency Curve Efficiency (%) Ingecon Sun Box 730 M320 Vdc = 550 V 100,00 98,00 96,00 94,00 92,00 90,00 88,00 86,00 84,00 82,00 80,00 0 10 20 30 40 50 60 70 80 90 100 P/Pnom (%) Ingecon Sun 730 M320 Indoor MAIN AC POWER CONNECTION Size (WxDxH) and Weight Box 365 M320 Outdoor Box 550 M320 Outdoor Box 730 M320 Outdoor 2987 x 1067 x 2681 mm 3587 x 1067 x 2681 mm 4209 x 1067 x 2681 mm 2080 Kg 2780 Kg 3480 Kg

Input 400 M345 Outdoor 600 M345 Outdoor 800 M345 Outdoor Recommended PV array power range (1) 448-520 kwp 672-780 kwp 896-1040 kwp MPPT input DC voltage range 502-820 V 502-820 V 502-820 V Maximum Input DC voltage (2) 920 V 920 V 920 V Maximum input DC current 800 A 1200 A 1600 A Number of DC inputs 8 12 16 DC connection type Number of power stages 2 3 4 Number of independent MPPT 2 3 4 Input Protection DC switch Class II DC surge arresters (for each power stage) DC breaker with door control (for each power stage) DC fuses, DC contactor for disconnection from PV array, DC insulation monitor with alarm (for each power stage) Output AC rated power (3) 440 kw 660 kw 880 kw AC maximum current 736 A 1104 A 1472 A AC rated voltage 345 V IT system 345 V IT system 345 V IT system Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Cos Phi (4) 1 1 1 Adjustable Cos Phi ± 0.9 at Pnom ± 0.9 at Pnom ± 0.9 at Pnom THD (Total Harmonic Distortion) (4) < 3 % < 3 % < 3 % AC connection type Output Protection AC switch Anti-islanding protection Class II AC surge arresters (for each power stage) AC thermal-magnetic switch with door control (for each power stage) Yes, with automatic disconnection (for each power stage) AC short circuits and overload (for each power stage) Performance Maximum efficiency 98.8 % 98.8 % 98.8 % European efficiency / CEC 98.5 % / 98 % 98.5 % / 98 % 98.5 % / 98 % Stand-by consumption (5) 60 W 90 W 120 W Night-time consumption < 5 W < 5 W < 5 W General Information Ambient temperature range -20 C to +65 C -20 C to +65 C -20 C to +65 C Relative humidity 0 to 95 % 0 to 95 % 0 to 95 % Protection class IP 54 IP 54 IP 54 Maximum operating altitude (6) Cooling system 3000 m a.s.l. Air forced with temperature control (400 V three phase + neutral power supply) Required air cooling flow 4000 m 3 /h (fans power 1590 W) 8000 m 3 /h (fans power 2770 W) 8000 m 3 /h (fans power 3180 W) Noise emission Marking < 55 db (A) at 4 m and < 67 db (A) at 1 m with fans working at maximum power CE Safety and EMC standards EN 50178, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC part 15 Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI 11-20 V1, CEI 0-16, Allegati A68 e A70 TERNA, CEI 0-21, IEEE1547, Arrêté 23-04-08 Size and Weight Size (WxDxH) 2987 x 1067 x 2681 mm 3587 x 1067 x 2681 mm 4209 x 1067 x 2681 mm Weight 2080 Kg 2780 Kg. 3480 Kg. Notes: (1) Depending on the PV modules type and geographical location. (2) 1000 Vdc optional. It must not be exceeded under any circumstances. Consider the voltage increase of the VOC at low temperatures. (3) AC power up to 40 C of ambient temperature. For each C of increase up to 50 C the output power will be reduced of 1.8 %. To achieve the maximum output power in any operating conditions it is recommended a strings configuration with VOC close to 920 V. (4) For Pout > 25% of the rated power and voltage in accordance with IEC 61000-3-4. (5) Consumption from PV field. (6) Rated AC power up to 1200 m a.s.l. without derating. For higher altitudes, please contact Ingeteam.

Efficiency 400 M345 Outdoor 600 M345 Outdoor 800 M345 Outdoor Maximum Efficiency 98.8 % 98.8 % 98.8 % European Efficiency / CEC 98.5 % / 98 % 98.5 % / 98 % 98.5 % / 98 % Efficiency @ Poutput = 5% rated power 97.0 % 97.0 % 97.0 % Efficiency @ Poutput = 10% rated power 98.1 % 98.1 % 98.1 % Efficiency @ Poutput = 20% rated power 98.7 % 98.7 % 98.7 % Efficiency @ Poutput = 30% rated power 98.8 % 98.8 % 98.8 % Efficiency @ Poutput = 50% rated power 98.7 % 98.7 % 98.7 % Efficiency @ Poutput = 100% rated power 98.2 % 98.2 % 98.2 % Efficiency Curve Efficiency (%) Ingecon Sun Box 800 M345 Vdc = 600 V 100,00 98,00 96,00 94,00 92,00 90,00 88,00 86,00 84,00 82,00 80,00 0 10 20 30 40 50 60 70 80 90 100 P/Pnom (%) Ingecon Sun Box 800 M345 Outdoor MAIN AC POWER CONNECTION Size (WxDxH) and Weight Box 400 M345 Outdoor Box 600 M345 Outdoor Box 800 M345 Outdoor 2987 x 1067 x 2681 mm 3587 x 1067 x 2681 mm 4209 x 1067 x 2681 mm 2080 Kg 2780 Kg 3480 Kg

Input 420 M360 Outdoor 630 M360 Outdoor 840 M360 Outdoor Recommended PV array power range (1) 466-546 kwp 700-819 kwp 933-1092 kwp MPPT input DC voltage range 524-820 V 524-820 V 524-820 V Maximum Input DC voltage (2) 920 V 920 V 920 V Maximum input DC current 800 A 1200 A 1600 A Number of DC inputs 8 12 16 DC connection type Number of power stages 2 3 4 Number of independent MPPT 2 3 4 Input Protection DC switch Class II DC surge arresters (for each power stage) DC breaker with door control (for each power stage) DC fuses, DC contactor for disconnection from PV array, DC insulation monitor with alarm (for each power stage) Output AC rated power (3) 458 kw 688 kw 917 kw AC maximum current 736 A 1104 A 1472 A AC rated voltage 360 V IT system 360 V IT system 360 V IT system Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Cos Phi (4) 1 1 1 Adjustable Cos Phi ± 0.9 at Pnom ± 0.9 at Pnom ± 0.9 at Pnom THD (Total Harmonic Distortion) (4) < 3 % < 3 % < 3 % AC connection type Output Protection AC switch Anti-islanding protection Class II AC surge arresters (for each power stage) AC thermal-magnetic switch with door control (for each power stage) Yes, with automatic disconnection (for each power stage) AC short circuits and overload (for each power stage) Performance Maximum efficiency 98.8 % 98.8 % 98.8 % European efficiency / CEC 98.6 % / 98.1 % 98.6 % / 98.1 % 98.6 % / 98.1 % Stand-by consumption (5) 60 W 90 W 120 W Night-time consumption < 5 W < 5 W < 5 W General Information Ambient temperature range -20 C to +65 C -20 C to +65 C -20 C to +65 C Relative humidity 0 to 95 % 0 to 95 % 0 to 95 % Protection class IP 54 IP 54 IP 54 Maximum operating altitude (6) Cooling system 3000 m a.s.l. Air forced with temperature control (400 V three phase + neutral power supply) Required air cooling flow 4000 m 3 /h (fans power 1590 W) 8000 m 3 /h (fans power 2770 W) 8000 m 3 /h (fans power 3180 W) Noise emission Marking < 55 db (A) at 4 m and < 67 db (A) at 1 m with fans working at maximum power CE Safety and EMC standards EN 50178, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC part 15 Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI 11-20 V1, CEI 0-16, Allegati A68 e A70 TERNA, CEI 0-21, IEEE1547, Arrêté 23-04-08 Size and Weight Size (WxDxH) 2987 x 1067 x 2681 mm 3587 x 1067 x 2681 mm 4209 x 1067 x 2681 mm Weight 2080 Kg 2780 Kg. 3480 Kg. Notes: (1) Depending on the PV modules type and geographical location. (2) 1000 Vdc optional. It must not be exceeded under any circumstances. Consider the voltage increase of the VOC at low temperatures. (3) AC power up to 40 C of ambient temperature. For each C of increase up to 50 C the output power will be reduced of 1.8 %. To achieve the maximum output power in any operating conditions it is recommended a strings configuration with VOC close to 920 V. (4) For Pout > 25% of the rated power and voltage in accordance with IEC 61000-3-4. (5) Consumption from PV field. (6) Rated AC power up to 1200 m a.s.l. without derating. For higher altitudes, please contact Ingeteam.

Efficiency 420 M360 Outdoor 630 M360 Outdoor 840 M360 Outdoor Maximum Efficiency 98,8 % 98,8 % 98,8 % European Efficiency / CEC 98.6 % / 98.1 % 98.6 % / 98.1 % 98.6 % / 98.1 % Efficiency @ Poutput = 5% rated power 97.1 % 97.1 % 97.1 % Efficiency @ Poutput = 10% rated power 98.2 % 98.2 % 98.2 % Efficiency @ Poutput = 20% rated power 98.7 % 98.7 % 98.7 % Efficiency @ Poutput = 30% rated power 98.8 % 98.8 % 98.8 % Efficiency @ Poutput = 50% rated power 98.8 % 98.8 % 98.8 % Efficiency @ Poutput = 100% rated power 98.3 % 98.3 % 98.3 % Efficiency Curve Efficiency (%) Ingecon Sun Box 840 M360 Vdc = 625 V 100,00 98,00 96,00 94,00 92,00 90,00 88,00 86,00 84,00 82,00 80,00 0 10 20 30 40 50 60 70 80 90 100 P/Pnom (%) Ingecon Sun Box 840 M360 Outdoor MAIN AC POWER CONNECTION Size (WxDxH) and Weight Box 420 M360 Outdoor Box 630 M360 Outdoor Box 840 M360 Outdoor 2987 x 1067 x 2681 mm 3587 x 1067 x 2681 mm 4209 x 1067 x 2681 mm 2080 Kg 2780 Kg 3480 Kg

Box 220 / 275 / 300 / 320 / 345 / 360 Vac Ingeteam Power Technology, S.A. Energy Avda. Ciudad de la Innovación, 13 31621 SARRIGUREN (Navarra) - Spain Tel.: +34 948 28 80 00 Fax.: +34 948 28 80 01 e-mail: solar.energy@ingeteam.com Ingeteam S.r.l. Via Emilia Ponente, 232 48014 CASTEL BOLOGNESE (RA) - Italy Tel.: +39 0546 651490 Fax: +39 0546 655391 e-mail: italia.energy@ingeteam.com web: www.ingeteam.it Ingeteam GmbH DE-153762639 Herzog-Heinrich-Str. 10 80336 MUNICH - Germany Tel.: +49 89 99 65 38 0 Fax.: +49 89 99 65 38 99 e-mail: deutschland@ingeteam.com Ingeteam SAS Parc Innopole BP 87635-3 rue Carmin - Le Naurouze B5 F- 31676 Toulouse Labège cedex - France Tel: +33 (0)5 61 25 00 00 Fax: +33 (0)5 61 25 00 11 e-mail: france@ingeteam.com Ingeteam INC. Headquarters 3550 W. Canal St. MILWAUKEE, WI 53208 - EE.UU. Tel.: 1 414 934 4100 Toll Free: 1 (855) 821-7190 e-mail: usa@ingeteam.com Ingeteam INC. 5201 Great American Parkway, Suite 320 SANTA CLARA, CA 95054 - USA Tel.: +1 (408) 524 2929 Fax.: +1 (408) 824 1327 e-mail: solar.us@ingeteam.com Ingeteam S.A. de C.V. Ave. Revolución, 643, Local 9 Colonia Jardín Español - Monterrey, N.L. 64820 - Mexico Tel.: +52 81 8311 4858 Fax: +52 81 8311 4859 e-mail: northamerica@ingeteam.com Ingeteam Ltda. Rua Luiz Carlos Brunello, 286 Chácara Sao Bento 13278-074 VALINHOS SP - Brazil Tel.: +55 19 3037 3773 Fax.: +55 19 3037 3774 e-mail: brazil@ingeteam.com Ingeteam, a.s. Technologická 371/1 70800 OSTRAVA - PUSTKOVEC Czech Republic Tel.: +420 59 732 6800 Fax.: +420 59 732 6899 e-mail: czech@ingeteam.com Ingeteam Shanghai, Co. Ltd. Shanghai Trade Square, 1105 188 Si Ping Road 200086 SHANGHAI - P.R. China Tel.. +86 21 65 07 76 36 Fax.: +86 21 65 07 76 38 e-mail: shanghai@ingeteam.com www.ingeteam.it italia.energy@ingeteam.com