Installation Dynamic Line I Dynamic Line II Dynamic Line III Baseline TA Motor

Similar documents
COMBIVERT LINE. GB INSTRUCTION MANUAL IO-Filter COMBILINE COMBIVERT L1 L2 L3 U V W E5EE0-K110

COMBIVERT R6 LINE REGEN SYSTEMS UP TO 1000 KVA V EN

THE SOLUTION. Powered and controlled by KEB! hoist. trolley. slewing. luffing. Construction cranes. Container cranes. Harbour cranes.

KEB COMBIVERT R6. Energy saving by using the feed-back an environmental contribution that pays off!

INSTRUCTION MANUAL. Dynamic Line II. GB Servo Motors SM.D Size A1 E3. for COMBIVERT H6 00SM0EB-K016

COMBIVERT R6 MADE IN. Line Regen Systems Up to 1000 kva

DYNAMIC LINE SERVO MOTORS EN

COMBIVERT F5-A-Servo

BETRIEBSANLEITUNG INSTRUCTION MANUAL

COMBIVERT G6. HIGH PERFORMANCE INVERTER kw V EN

CombiVERT R6 LINE REGEN SYSTEMS

COMBIVERT ACCESSORIES INSTRUCTIONS FOR USE INSTALLATION BRAKING RESISTORS. Translation of the original manual Document EN 02

COMBIVERT. F5-A-Servo. closed loop und sensorless closed loop

COMBIVERT. GB INSTRUCTION MANUAL Power Circuit kw 00F50EB-K004. Read Instruction manual part 1 first!

COMBILINE MADE IN GERMANY. EMC solutions

G6 GCOMBIVERT G6 MADE IN GERMANY. High Performance Inverter kw

INSTRUCTION MANUAL. Dynamic Line I. GB Servo motors Size A1 F3 00SM0EB-K014

VEM motors Thurm GmbH

INSTRUCTION MANUAL. Dynamic Line II. GB Servo Motors SM.5 Size A1 E3 00SM0EB-K013

INSTRUCTION MANUAL. Dynamic Line. Translation of original manual. Document Part Version GBR 00

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

BETRIEBSANLEITUNG INSTRUCTION MANUAL

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

SERVO MOTORS BRUSHLESS SERVO MOTORS ATEX ZONE 2-22 OPERATING INSTRUCTIONS 2016

Appendix: Safety and application notes for... 15

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev

Technical Manual Electrical Power Supply System T4002

MADE IN GERMANY COMBIVERT H6. Multi Axis Drives

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

ASYNCHRONOUS MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS INSTRUCCIONES DE SERVICIO OPERATING INSTRUCTIONS 2016

Operating Instructions for Roll-Up Door Operators / MDF

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Solenoid Operator 0513 / 1213

EStrong-series Emergency Stop

Solenoid Operator 0516 / 1216

B 1091 en. Motors. Operating and Assembly Instructions

High Voltage Safety. General Safety Instructions for High Voltage Machines. W. Maes. Department of Marine Engineering Antwerp Maritime Academy

BETRIEBSANLEITUNG INSTRUCTION MANUAL

Table of contents. Three-phase asynchronous motors DA

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

Installation Instructions

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

TGN, TGH AND TGT SERVOMOTORS

General operation manual. induction cage-motors

SMH High Torque Density

BA EN.5ôE. Ä.5ôEä. Operating Instructions SDSGA. Inverter optimised asynchronous motors

23 Synchronous servo motors EZ

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Wilo-Control SC-Fire Jockey

ZE motor-protective relay Overload monitoring of EEx e motors

Operating / Assembly Instructions Type A and CS Coupling

Installation and Operating Instructions. Vibratory hopper. Type BV. Type BVL

Hollister-Whitney Elevator Corporation

LV Capacitor CLMD03 Power Module Instruction manual

User Manual Rittal PMC UPS 6kVA

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

1 Article designation

Ex m Solenoid Operator Type 0519

Operating Instructions

RGZESDI Inverter Duty AC Induction Motors

Commissioning Manual AC Servo Actuator LynxDrive SIEMENS SIMODRIVE

Product Information ECN 425 EQN 437. Absolute Rotary Encoders with Hollow Shaft and Expanding Ring Coupling for Safety-Related Applications

Technical Documentation

1 Article designation

Tina 4A Connection block

Index. Cable Brakemotor cable for decentralized MOVI SWITCH Catalog AC Motors DR , DT56, DR /EN 10/14

0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd

DRIVESPIN ROTARY ACTUATORS

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

ASYNCRONOUS MOTORS OPERATING INSTRUCTIONS 2018

BMH. Servo motor Motor manual V2.1, , V2.1,

SIZING OF SOLAR GENERATOR

Tina 11A Connection block

SCOPELITE TIMING LIGHT OPERATING MANUAL

INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For THREE-PHASE INDUCTION MOTORS TYPE HJN / HJA

Swing Piston Compressors and Vacuum Pumps

BAH series Use and Maintenance Manual

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Lenze. Drives with worm gearboxes 52.

Description AX5806. List of permissible motors. Version: Date:

Installation and Operating Instructions Electric Vibrators HV/VFL Series

Use and maintenance manual and ATEX provisions

BoWex FLE-PA. BoWex FLE-PAC. KTR-N Sheet: Edition: EN 1 of BoWex FLE-PA / FLE-PAC Operating/Assembly instructions

BODAS Pressure sensor PR3 series 10

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Level Measuring Sensor for Diesel Fuel Tanks

Rexroth IndraDyn E. Standard Motors MOT-FC for Frequency Converter Operation. Project planning manual R Edition 03

FACTORY AUTOMATION MANUAL ENI11HD

Assembly and Maintenance Manual Type ASNU

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

Appendix: Safety and application notes for 19

MODVAR Low voltage reactive power compensation modules Installation manual

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning.

Aurora Wind Interface Box

BA EN.CD( Ä.CD(ä. Operating Instructions SDS.. SDSGS. Synchronous servo motors

PERFECT COMBINATION EFFICIENTLY USED. Competent customer consulting Professional selection Integrated tools Powerful products Reliable quality

Bowl feeder WV401-1 / Translation of operating and installation instructions

Transcription:

Installation Dynamic Line I Dynamic Line II Dynamic Line III Baseline TA Motor GB Safety and start-up of three-phase motors Mat.No. 00SMNEM-000 Rev. 1B

1. General The use of our units in the target products is outside of our control and therefore lies exclusively in the area of responsibility of the machine manufacturer. The information contained in the technical documentation, as well as any user-specific advice in spoken and written and through tests, are made to best of our knowledge and information about the application. However, they are considered for information only without responsibility. This also applies to any violation of industrial property rights of a third-party. Selection of our units in view of their suitability for the intended use must be done generally by the user. Tests can only be done by the machine manufacturer in combination with the application. They must be repeated, even if only parts of hardware, software or the unit adjustment are modified. Unauthorised opening and tampering may lead to bodily injury and property damage and may entail the loss of warranty rights. Original spare parts and authorized accessories by the manufacturer serve as security. The use of other parts excludes liability for the consequences arising out of. The suspension of liability is also valid especially for operation interruption damages, loss of profit, data loss or other damages. This is also valid, if we referred first to the possibility of such damages. If individual regulations should be futile, not effective or impracticable, then the effectivity of all other regulations or agreements is not affected by this. Qualified personnel Three-phase motors have dangerous, live parts and rotating components as well as surfaces that may become hot. Improper assembly, installation, startup, operation and maintenance as well as unauthorized removal of covers and other protective measures may result in serious injury and damage to property. Only qualified personnel are allowed to perform any planning, installation or maintenance work (observe EN 50110-1, DIN VDE 0105-100, IEC 364). The personnel must be trained for the job and must be familiar with the installation, assembly, start-up and operation of the product. The applicable national, local and works regulations and requirements must be complied with. The instructions given in the manual or any other documentation must always be observed. Improper operation can cause damages to personnel and equipment. Non-observance of the safety instructions leads to the loss of any liability claims. This list is not exhaustive. 2. Intended use Three-phase motors are intended for industrial systems. They comply with the harmonized standards of the series EN 60034 (VDE 0530). Utilization in areas subject to explosion hazard is not permitted, unless expressly intended for this purpose. If requirements are more strict it is the responsibility of the customer to ensure compliance on installing the equipment. The conditions on site must correspond to all rating plate specifications respectively information in the instruction manual. This applies particularly to the degree of protection, ambient temperature and site altitude. Components for installation Low voltage motors are components for installation in machinery in terms of the machine directive 2006/42/EC. Commissioning must not take place until it has been provided that the end product conforms with this guideline (please note EN 60204-1). No mains operation Download INSTRUCTION MANUAL The motors are not designed for direct connection to the three-phase system but are to be operated via an electronic power inverter. Direct connection to the system may destroy the motor. This installation manual contains only an excerpt from the instruction manual. The instruction manual is available for download on our homepage www. keb.de. GB -2

3. Transport and storage Transport Any damage detected after delivery should be reported immediately to the transport company. Damaged products may not be set into operation. The eyebolts are designed for the weight of the motor only therefore do not attach any additional loads. Do not transport machines on the fan cover. If necessary, use suitable, adequately dimensioned transporting equipment (e.g. rope guides). Storage Storage only in dry and dust-free rooms, protected against mechanical damage and vibration (v eff 0.2 mm/s) (bearing standstill damage). Do not store machines on the fan cover! On long-term storage, the grease interval of the bearings is reduced. Checking of bearing grease must be carry out when motors are longer than 12 months storaged. When storage conditions are the cause of grease depreciation (ingress of condensate, consistency change) the grease must be exchanged. Grease exchanging must be carry out no later than in three year interval. 4. Installation Remove existing shipping braces and reuse for subsequent transport. Measure insulating resistance before commissioning (for values 1kΩ/V rated voltage dry winding). Remove rust-proofing of the output shaft before assembly and grease joining area Ensure an even underlying surface, good foot or flange fixing and precise alignment for direct coupling. Observe maximum length of the used flange fixing screws! Observe preset screw tightening torque at the assembly of shrink discs. Components to be assembled on the motor shaft end must be balanced dynamically. Rotors are balanced ex factory with half feather key. The balancing type is specified on the shaft end face or rating plate (H = half-, F = full-key balancing). Couplings or other transmission elements may be mounted only with the help of the helical threaded hole in the output shaft. Avoid shocks and impacts during installation of transmission elements (possibly warm-up). Coupling elements must be covered during operating. Avoid resonances with the rotary frequency and double mains frequency. Do not obstruct ventilation, observe minimum distances to the cooling air supply. Avoid re-suctioning of the heated cooling air. Prevent falling from foreign bodies for construction types with vertical motor assembly. Turn rotor by hand, pay attention to unusual slipping noises. Check direction of rotation in decoupling state Avoid resonances with the rotary frequency and double mains frequency. Damage can be caused for motors with cylinder roller bearing for increased radial load by the operation with smaller than the minimum radial load. The radial load should be at least 30% of the maximum permissible radial load during operation. Avoid inadmissible belt tensions! No foreign bodies, dirt and moisture may be in the terminal box. Close non-required cable entry-holes and the box itself dust and waterproof. GB -3

5. Electrical connection Dangerous voltage During the operation (even at zero speed) the motors posses dangerous live parts. In the case of synchronous motors with rotating rotor a high voltage is applied onto the motor connections. All work may be carried out only by qualified technical personnel on the motor at rest in de-energized status and secured against restarting. This also applies to auxiliary circuits (e.g. separately-driven fan).the isolation from supply must be checked. If the permissible tolerance limits are exceeded that are specified in EN 60034-1/ IEC 34-1 (voltage ±5 %, frequency ±2 %, shape of curve and symmetry) the heating effect is increased and the electromagnetic compatibility is affected. Please note the specifications on the rating plate and the connection diagram in the terminal box. The following minimum clearances must be observed in the terminal box (prevent protruding wire ends): UN 550 V = 8 mm UN 25 V = 10 mm The thermistor fitted in the winding is to be connected and evaluated by a suitable wiring, for the protection of the motor against thermal overload in case of slow changes. Attention: The temperature switch offers no comprehensive protection of the winding. Suitable measures in the controller electronic are required to protect the motor against thermal overload in case of fast changes. Absolutely observe the direction of rotation in case of separate ventilation! Secure feather key for the test run without output components. A varistor should be connected parallel to the brake coil of the holding brake. Degree of protection The connection must be carried out in such a way that a permanently safe, electrical connection is maintained. Pay attention to a safe protective conductor connection. In the case of improper execution of the work the type of protection IP65 is no longer warranted. If connector systems are used, then the type of protection IP65 is only achieved with correctly wired and firmly tightened mating connector. 5.1 Motor connection Assignment of the motor cable Motor Brake* Temperature sensor Description U V W PE + - T1 (+) T2 (-) Marking at the cable 1 2 3 greenyellow 5 6 8 * Optional (supply via external braking power supply unit) GB -4

Connector assignment at the motor Motor size Terminal assignment Connector motor side size 1,0 Ax DxSM5xx-xxxx 1 Motor phase U Ax ExSM0xx-xxxx TA2x...TA5xxx-xxxx Protective earth D 3 2x xsm2xx-xxxx C 3 Motor phase W 4 Motor phase V A Brake + B Brake - C Temperature sensor + GB Temperature sensor - B A 1 4 2 Motor size Terminal assignment Connector motor side size 1.5 ExSM5xx-xxxx U Motor phase U FxSM0xx-xxxx V Motor phase V TA6xxxx-xxxx - V + W Motor phase W 8xSM2xx-xxxx Protective earth W U 5.2 Encoder connection + Brake + - Brake - 1 Temperature sensor + 2 Temperature sensor - 2 1 Resolver Resolver plug View No. Signal Color Angle socket 1 SIN- red rotatable 2 COS- pink 9 12-pole 1 8 5 REF- yellow Connector 2 10 12 6 10 REF+ SIN+ green blue 3 11 5 11 COS+ gray View of the connector pins at the motor 4 All other contacts are not assigned. Encoder cable A-Servo 00F50C1-0yyy F5-Multi 00F50C1-1yyy ready-made, shielded, trailing capable, yyy - line length [m] GB -5

Hiperface Hiperface connector View No. Signal Color Angle socket 4 REF_SIN- red rotatable 5 REF_COS- yellow 12-pole 9 6 Data+ gray 8 Connector 1 Data- pink 8 SIN+ blue 2 10 12 6 9 COS+ green 11 3 5 10 +.5 V brown 4 View of the connector pins at the 11 COM white motor All other contacts are not assigned. Encoder cable F5-Multi 00S4809-yyyy ready-made, shielded, trailing capable, yyyy - line length [m] EnDat EnDat-connector View No. Signal Color Angle socket +5V white rotatable 8 Clock+ black 3 4 1-pole 9 Clock- purple 2 13 5 Connector 10 COM brown View of the connector pins at the motor 1 14 6 1 12 15 11 16 10 8 9 Encoder cable 00F50C1-4yyy ready-made, shielded, trailing capable, yyyy - line length [m] 12 B+ blue 13 B- red 14 Data+ gray 15 A+ green 16 A- yellow 1 Data- pink All other contacts are not assigned. SIN/COS SIN/COS-connector View No. Signal Color Angle socket 1 A+ green rotatable 2 A- yellow 1-pole 3 4 3 R+ gray Connector 5 4 D- purple View of the connector pins at the motor 2 13 1 14 6 1 12 15 11 16 10 8 9 5 C+ white 6 C- brown COM white/green 10 +5V gray/pink 11 B+ blue 12 B- red 13 R- pink 14 D+ black All other contacts are not assigned. Encoder cable ready-made, shielded, trailing capable, yyyy - line length [m] 00S4209-yyyy GB -6

BiSS BiSS connector View No. Signal Color Angle socket 15 A+ green rotatable 16 A- yellow 3 4 12-pole 12 B+ blue 2 13 5 Connector 13 B- red View of the connector pins at the motor 1 14 6 1 12 15 11 16 10 8 9 14 DATA+ gray 1 DATA- pink 8 CLOCK+ black 9 CLOCK- purple 10 COM white +5,25V brown All other contacts are not assigned. Encoder cable ready-made, shielded, trailing capable, yyyy - line length [m] 00.F5.0C1-V0yy GB -

5.3 Separate ventilator connection Separate ventilator connection Cx DxSM5xx-xxxx Cx ExSM0xx-xxxx ExSM5xx-xxxx FxSM0xx-xxxx TAxxxxx-xxxx View of the connector pins at the motor 1 2 3 1 Terminal assignment 1 L1 0.12 A 1 U 1 x 230 Vac 2 N 0.30 A 2 V 3 W 6. Start-up/operation 2 3 x 400 Vac 0.15 A PE Protective earth PE Protective earth For motors with brakes, check that the brakes are operating perfectly before start-up. Secure the feather key on the test operation of the motor without coupling elements! In the case of motors with separate ventilation, the separately-driven fan must be switched on throughout motor operation. Do not disconnect protective equipment, even under test operation. Operate drive temporarily idle and check for irregularities. Pay attention to temperatures, noise, vibrations. In case of doubt, switch off the motor. Switch load - vibration levels of veff 3.5 mm/s (PN 15 kw) and 4.5 mm/s (PN 15 kw) are quite acceptable in the coupled mode. Check the current input at load. If deviations from normal operation occur (vibration, noises) or increased temperatures determine the causes and contact the manufacturer if necessary. Under dirty operating condition, clean the air channels regularly. Check occasionally the air gap at mounted brake. Adjustment, if the air gap has reached the level Xn (see type plate).. EC Manufacturer s Declaration CE marked motors were developed and manufactured to comply with the regulations of the Low-Voltage Directive 2006/95/EC. The motors must not be started until it is determined that the installation complies with the machine directive (2006/42/EC) as well as the EC EMC Directive (2004/108/EC). If necessary, a manufacturer's declaration is available at KEB. 8. Further information Information provided about any additional equipment must be observed! These notes on safety and commissioning must be retained for future reference! For more details please refer to our detailed instruction manual and maintenance guide. GB -8

Notes D - 9

KEB Automation KG Südstraße 38 D-32683 Barntrup fon: +49 5263 401-0 fax: +49 5263 401-116 net: www.keb.de mail: info@keb.de KEB worldwide KEB Antriebstechnik Austria GmbH Ritzstraße 8 A-4614 Marchtrenk fon: +43 243 53586-0 fax: +43 243 53586-21 net: www.keb.at mail: info@keb.at KEB Antriebstechnik Herenveld 2 B-9500 Geraadsbergen fon: +32 5443 860 fax: +32 5443 898 mail: vb.belgien@keb.de KEB Power Transmission Technology (Shanghai) Co.,Ltd. No. 435 Qianpu Road, Chedun Town, Songjiang District, CHN-Shanghai 201611, P.R. China fon: +86 21 346688 fax: +86 21 346600 net: www.keb.de mail: info@keb.cn KEB Antriebstechnik Austria GmbH Organizační složka K. Weise 165/5 CZ-30 04 České Budějovice fon: +420 38 699 111 fax: +420 38 699 119 mail: info.keb@seznam.cz KEB Antriebstechnik GmbH Wildbacher Str. 5 D 08289 Schneeberg fon: +49 32 6-0 fax: +49 32 6-281 mail: info@keb-drive.de KEB España C/ Mitjer, Nave 8 - Pol. Ind. LA MASIA E-0898 Sant Cugat Sesgarrigues (Barcelona) fon: +34 93 89 0268 fax: +34 93 899 2035 mail: vb.espana@keb.de Société Française KEB Z.I. de la Croix St. Nicolas 14, rue Gustave Eiffel F-94510 LA QUEUE EN BRIE fon: +33 1 49620101 fax: +33 1 456495 net: www.keb.fr mail: info@keb.fr KEB (UK) Ltd. Morris Close, Park Farm Industrial Estate GB-Wellingborough, NN8 6 XF fon: +44 1933 402220 fax: +44 1933 40024 net: www.keb.co.uk mail: info@keb.co.uk KEB Italia S.r.l. Via Newton, 2 I-20019 Settimo Milanese (Milano) fon: +39 02 3353531 fax: +39 02 3350090 net: www.keb.de mail: kebitalia@keb.it KEB Japan Ltd. 15 16, 2 Chome, Takanawa Minato-ku J-Tokyo 108-004 fon: +81 33 445-8515 fax: +81 33 445-8215 mail: info@keb.jp KEB Korea Seoul Room 109, 415 Missy 2000 25 Su Seo Dong, Gang Nam Gu ROK-135-5 Seoul/South Korea fon: +82 2 6253 61 fax: +82 2 6253 60 mail: vb.korea@keb.de KEB RUS Ltd. Lesnaya Str. House 30, Dzerzhinsky (MO) RUS-140091 Moscow region fon: + 495 632 021 fax: + 495 632 021 net: www.keb.ru mail: info@keb.ru KEB America, Inc. 5100 Valley Industrial Blvd. South USA-Shakopee, MN 5539 fon: +1 952 224-1400 fax: +1 952 224-1499 net: www.kebamerica.com mail: info@kebamerica.com More and latest addresses at http://www.keb.de KEB Mat.No. 00SMNEM-000 Rev. 1B Date 10/2016