Manifold system Manifold plate Valve ports V6 V6 V62 Model kg Model kg Model kg 2 2222,23 3 2223,28 4 2224,6 6 2226,86 8 2228, 222,36 2 2222,6 4 2224,86 6 2226 2, 8 2228 2,36 2 2222 2,6 2222,28 2223,45 2224,72 2226,2 2228,32 222,62 2222,92 2224 2,22 2226 2,52 2228 2,82 2222 3,2 22222,5 22223,85 22224,25 22226,79 22228 2,33 2222 2,87 22222 3,4 22224 3,95 22226 4,49 22228 5,3 22222 5,57 Drawing dimensions Manifold plate 2 stations + 3 stations Manifold plate 4 stations 2 stations C D A B M C D A B M G H F E J K N S T G H F E J K N U T U R O P O P R Type A B C D E F G H J K M N O P R S T U V6 2 stations 49 98 3 6 8 2 32 35,5 46 G /8 G /4 6 86 28 23 for M5 V6 3 stations 49 98 3 6 8 2 32 35,5 69 G /8 G /4 6 86 28 23 for M5 V6 4-2 stations 49 98 3 6 8 2 32 35,5 (x 23)+23 G /8 G /4 6 86 6,5 (x 23)+ 23 for M5 V6 2 stations 52 4 26 9 8 3 2 33 35,5 52 G /8 G 3/8 4 24 26 26 for M5 V6 3 stations 52 4 26 9 8 3 2 33 35,5 78 G /8 G 3/8 4 24 52 26 for M5 V6 4-2 stations 52 4 26 9 8 3 2 33 35,5 (x 26)+23 G /8 G 3/8 4 24 6,5 (x 26)+ 26 for M5 V62 2 stations 6 2 29 9 8 5 22 38 3 35,5 7 G /8 G /2 44 32 35 35 for M6 V62 3 stations 6 2 29 9 8 5 22 38 3 35,5 5 G /8 G /2 44 32 7 35 for M6 V62 4-2 stations 6 2 29 9 8 5 22 38 3 35,5 (x 35)+26 G /8 G /2 44 32 7 (x 35)+2 35 for M6 N/UK 5.4.34.4 5/2
Manifold system For common pressure supply A M I Manifold 2 to 2 stations complete with connecting and sealing elements Types see table below Bracket for manifold 555485 (V6),8 kg 555484 (V6),5 kg Blanking plug for unused valve station 49586 (V6), kg 49587 (V6),2 kg Drawing dimensions B C D E K ø H N F G P R Pressure supply on both sides if 4 or more valves are to operate at the same time. Type No. of stations A B C D E F G Ø H I K M N P R kg V6 2639622 2 G/4 76 32 22 4 9 6 6,5 2,5 6 6 G/8 48 28 42,53 2639623 3 G/4 8 32 22 4 22 38 6,5 2,5 6 6 G/8 48 28 42,75 2639624 4 G/4 4 32 22 4 54 7 6,5 2,5 6 6 G/8 48 28 42,99 2639625 5 G/4 72 32 22 4 86 22 6,5 2,5 6 6 G/8 48 28 42,23 2639626 6 G/4 24 32 22 4 28 234 6,5 2,5 6 6 G/8 48 28 42,47 2639627 7 G/4 236 32 22 4 25 266 6,5 2,5 6 6 G/8 48 28 42,74 2639628 8 G/4 268 32 22 4 282 298 6,5 2,5 6 6 G/8 48 28 42,94 2639629 9 G/4 3 32 22 4 34 33 6,5 2,5 6 6 G/8 48 28 42,29 263963 G/4 332 32 22 4 346 362 6,5 2,5 6 6 G/8 48 28 42,23 2639632 2 G/4 396 32 22 4 4 426 6,5 2,5 6 6 G/8 48 28 42,28 V6 2639422 2 G3/8 85 35 25 9 6 6,5 3 75 23 G/4 57 35 5,3 2639423 3 G3/8 2 35 25 9 35 5 6,5 3 75 23 G/4 57 35 5,92 2639424 4 G3/8 55 35 25 9 7 86 6,5 3 75 23 G/4 57 35 5,25 2639425 5 G3/8 9 35 25 9 25 22 6,5 3 75 23 G/4 57 35 5,39 2639426 6 G3/8 225 35 25 9 24 256 6,5 3 75 23 G/4 57 35 5,367 2639427 7 G3/8 26 35 25 9 275 29 6,5 3 75 23 G/4 57 35 5,42 2639428 8 G3/8 295 35 25 9 3 326 6,5 3 75 23 G/4 57 35 5,482 2639429 9 G3/8 33 35 25 9 345 36 6,5 3 75 23 G/4 57 35 5,537 263943 G3/8 365 35 25 9 38 396 6,5 3 75 23 G/4 57 35 5,595 2639432 2 G3/8 435 35 25 9 45 466 6,5 3 75 23 G/4 57 35 5,642 5/2 N/UK 5.4.34.5
Accessories Manifolds Blanking plate Blanking plug for 2 station and 3 station manifolds Pressure shut-off part for 4 station up to 2 station manifolds Intermediate supply/exhaust plate (instead of a valve) Adapter plate to connect different manifold sizes 56 (V6),5 kg 563 (V6),6 kg 565 (V62), kg 728 (V6),6 kg 729 (V6),2 kg 72 (V62),2 kg 567 (V6), kg 569 (V6),5 kg 57 (V62),2 kg 88 (V6), kg 797 (V6),22 kg 89 (V62),39 kg 258 (V6appleV6) on request 26 (V6appleV62) on request 262 (V6appleV62) on request Pressure switch adapter plate DIN Rail fixing kit Blanking plug for port 2/4 and 82/84 246 (V6),3 kg 248 (V6),6 kg 25 (V62),26 kg 796 (V6appleV62), kg Blanking plug for port, 3, 5 658 (V6appleV62),8 kg 6528 (V6),5 kg 6538 (V6),2 kg 6548 (V62),35 kg Valves Silencer sintered bronze Exhaust flow regulator without silencer Exhaust flow regulator with silencer Diffusor for pilot exhaust Circlip for coil fixing 44 M5,25 kg 45 G/8,8 kg 46 G/4, kg 47 G3/8,25 kg 48 G/2,6 kg 4484 G/8,25 kg 4484 G/4,6 kg (G3/8 on request) 4485 G/8,25 kg 4485 G/4,6 kg (G3/8 on request) 88,2 kg 826, kg Connectors Industrial standard 22 mm 2-pole + PE DIN EN 753-83 (DIN 4365 B) 2-pole + PE DIN EN 753-83 (DIN 4365 C) 3-pole + PE DIN EN 753-83 (DIN 4365 B) with AS-i Interface DIN EN 753-83 (DIN 4365 B) with AS-i Interface 657868,5 kg 2...25 V a.c./d.c. 68,5 kg 5...3 V d.c.; ED, surge suppression 68,5 kg 5...25 V a.c.; glim lamp 683,5 kg 2...25 V a.c./d.c. 6648,5 kg 5...3 V d.c.; ED, surge suppression 66482,5 kg 5...25 V a.c.; glim lamp 588666,2 kg 2...25 V a.c./d.c. 244,2 kg 2...25 V a.c./d.c.; cable 3 m 33,3 kg output 32,3 kg output + 2 inputs with M2 x N/UK 5.4.34.6 5/2
Mounting instructions DIN Rail. Mount screw in rod 3. Position manifold plate on DIN rail. 2. Fix rod on manifold plate with screw. 4. Tighten screws in steps as shown on picture 2.. Mounting instructions Pressure shut-off part. Set stopper at required position (in main pressure line). Stopper Stopfen / stopper Bushes Buchsen / bushes P P2 2. Plug-in two bushes to lock stopper in position. P P2 3. Mount valves on manifold plate (bushes rise into P port of valves). 5/2 N/UK 5.4.34.7
Extension possibilities with manifold plates V6 V6 V62 N/UK 5.4.34.8 5/2
Pneumatic pressure switch and sensors with flange connection ideal for sub-base mounting Series Technical data Pressure ranges/versions Type Data sheet 33D Electronic pressure switch/sensor x PNP; 2 x PNP; x PNP / 4... 2 ma For applications with high accuracy -... + bar, x PNP 8636 5..27 ubricated or unlubricated air and neutral gases -... + bar, 2 x PNP 86326 Electrical connection M2 x -... + bar, x PNP / 4... 2 ma 86346 UB =... 32 V d.c. (5... 32 V DC with 4... 2 ma)... 6 bar, x PNP 86326 Permanent indication of system pressure and unit are indicated... 6 bar, 2 x PNP 863226 Easy programming due to display informations... 6 bar, x PNP / 4... 2 ma 863246 CD-Display illuminated Piezo-resistant silicon-sensor Unit is progammable (bar, psi, kpa) Adjustments can be protected by code Set-/resetpoint, window or hysteresis mode programmable Time functions to 2 s programmable 8S Electronic pressure sensor 4... 2 ma, 2-wire technology For all standard applictions with permanent pressure control -... + bar (M2 x ) 86285 5..26 ubricated or unlubricated air and neutral gases... bar (M2 x ) 86285 Electrical connection M2 x or DIN 4365 A -... + bar (DIN 4365 A) 86286 UB =... 32 V d.c.... bar (DIN 4365 A) 86286 Output signal 4... 2 ma (RImax = ohm) inearity,5 % FS Piezo-resistant silicon-sensor 8D Electromechanical pressure switch For all standard applications with medium accuracy -... bar (DIN 4365 A) 88 5..2 (+/ 3 % repeatability),5... 8 bar (DIN 4365 A) 883 ubricated or unlubricated air and neutral gases -... bar (M2 x ) 886 Electrical connection M2 x or DIN 4365 A,5... 8 bar (M2 x ) 8836 Microswitch with goldplated contacts (SPDT) Approved by U and CSA 5/2 N/UK 5.4.34.9
Drawing dimensions 33D Front view Front view M 2 x Rear view (flange version) Rear view (Flange version).5 22 OUT HYS WIN OUT2 Flange diameter 8 x.2 deep 3 G/4 female Suitable for for M 5 x O-ring 35 5 x.5 (NBR) Pneumatics M 5 screws 2 screws O-ring 4.47 x.78 (FKM) Hydraulics/Allfluid Flange diameter 8 x,2 deep O-ring 5 x,5 (NBR) Pneumatics O-ring 4,47 x,78 (FKM) Hydraulics 8S 8D 2 x ø 5.2 3 3 3 M 2 x 4 25,7 22,5 82 3 2 3 3 5 9 SET 7.5 39.7 98 Incorporating 4 3 5 5.3 72 Ø ø 8 x x,2.2 deep deep 75 2 Ø ø 8 x,2.2 deep 5 5 O-ring 5 x,5.5 O-ring 5 x,5 O-ring 5 x.5 Pg Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. N/UK 5.4.34.2 5/2