Flameproof Alternator

Similar documents
Flameproof Alternator

Flameproof Alternator

Self-Exciting Flameproof Alternator

Flameproof Alternators

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run Types for Non-Hazardous Areas)

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

Automatic Fuel Shut Down Valves

SELECTION, APPLICATION AND MAINTENANCE

D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range)

Diesel Engine Shutdown System

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Stop Types)

D200 Spindle Type Automatic Engine Overspeed Air Intake Shut Down Valve (including Manual, Oil and Air Pressure Shut Down Control options)

Solenoid Actuated Diesel Engine Air Shut Down Valves

SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop)

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

Operating Instructions

System Selection Guide

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

Tri-Spark Ignition System Installation Triple Cylinder TRI-0001

Cable Glands - American Series - NEC/IEC

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

by AMOT World class diesel engine safety solutions Automatic Engine Overspeed Shut Down Valves - D Series

PLASTIC FOLDING ARM KIT This kit is designed for the 1600 model barrier gate operators only. Recommended for low headroom applications.

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

Armoured / Un-armoured Cable Gland

Diesel Engine Air Intake Shutoff Valves

Operating Instructions

Pressure and Temperature Switches

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS SOLAS LED Luminaire ATEX & IECEx

Operating Instructions

VALIADIS S.A. HELLENIC MOTORS

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDB3 Compact Butterfly Valve. by AMOT. Overview. Typical Applications

Diesel Engine Shutdown Valve

Diesel Engine Shutdown Valves

Modular Explosion Proof Brakes. IECLine rev 0

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

SVX-Series Solenoid Actuated Diesel Air Shut Down Valves

LIVE DEMATEABLE CONNECTOR TERMINATION / HOOK UP PROCEDURE

Instructions for: DIESEL ENGINE SETTING/LOCKING KIT - VOLKSWAGEN 2.5TDi - PUMP DüSE - GEAR DRIVE MODEL No: VS5035. Applications: Kit contents

by AMOT World class diesel engine safety solutions Product Selection Guide

ADE 6F ADE 6F. page 46

0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd

OPERATING INSTRUCTIONS

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel

Flameproof Level Sensor (Flameproof F/S FP)

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Operating Instructions. Valves Atkomatic Series ATEX and Series ATEX Series Series

TIMING BELT COMPONENTS EM 15

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,

HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop)

The ignition coil for the vehicles covered by this guide is in the following locations:


MVX-Series Diesel Engine Air Shut Down Valves

Installation, Operating & Maintenance Instructions. Norbro J-Switch FM 00707

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

ABG Cable Glands Installation Procedure

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL

II 2GD. xxxx. Westlock 2200 Series Quantum - ATEX certified Installation & Operating Instructions

English. Fitting Instructions: Street Triple Rx, Street Triple from VIN and Street Triple R from VIN A , A and A

Clarius EP PLUS LED FLOODLIGHT Installation Guide

INSTALLATION &SAFETY DATA SHEET

Cable Connectors GET CONNECTED

IECEx Certificate of Conformity

Flameproof Enclosures

Explosion and flame-proof single phase electric motors

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Explosion and flame-proof cast iron electric motors

2006 Expedition/Navigator Workshop Manual

Label Information: FPS75 FPS80 Cranking Warning Label

Modular Flameproof Brakes

The Earth-Rite MGV is designed to enable operators establish safe grounding of their vehicle in accordance with these recommended practices.

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

YT-720 SERIES. Rotork YTC Limited VERSION 1.07

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C

66 CHAPTER FOUR. Spark Plug Removal Refer to Figure 28 for spark plug wive routing according to engine.

Explosion Protected Group IIB Zone 1 Ex d Ring Enclosure Ex e Terminal Boxes Hollow Shaft Option OPERATING SPECIFICATION TECHNICAL DETAILS

Explosion protected terminal boxes type, GHG 72.

REMOVAL OF ALTERNATOR

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

630, 631 & 632 Bobcat & Melroe Bobcat

AI352 ATEX INLINE CONNECTOR TERMINATION PROCEDURE

26 - COOLING SYSTEM CONTENTS ENGINE COOLING - DESCRIPTION... 3 ENGINE COOLING - OPERATION... 9 COOLING SYSTEM FAULTS... 1

Welcome VA School Bus Technicians From


p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

SECTION C Engine 5.4L (3V)

Kopex-Ex cable glands offer superior protection in hazardous environments

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Installation Instructions Alternators 8LHA Series

Thermostatic Control Valve

Transcription:

Flameproof Alternator Installation, Operation and Maintenance Alternator Types ASX-400 ASX-401 CE242 (6) ASX_0210

DESCRIPTION Twelve pole rotating field coil type externally excited alternators designed and approved as Category 2G/D equipment and rated for a continuous output of 24 volts/50 Amperes at 6000 rpm. ASX-400 range alternators are marked as follows:- CHALWYN by AMOT, Bury St Edmunds, UK 0518 SIRA 07ATEX1171X TYPE ASX-400 SERIAL NO. xxxxx Ex d llb T4 (Ta = -30 c to 50 c) Ex td A21 IP66 T135 c II 2 G D OUTPUT 28V 50A MAX 7000RPM MAX Internal Cable Temp rise 84 C at Max Power - Use suitable Cable Thread Entries - M25 x 1.5 Minimum grade of cover fasteners 12.9 Warning. Do not open when explosive gas and/or dust atmosphere is present The outer enclosure of these alternators is manufactured from LM 25 castings. Fan, fan discs, cowls and pulleys are manufactured from carbon steel. Overall dimensions are as given below. A number of alternative single or multigroove pulleys are available. Contact Chalwyn Sales for up to date details of the standard range. Special pulleys are also available to customer design. ASX-400 The four alternative side entry gland positions are selected by unbolting and rotating the alternator rear cover. ASX-401 Four rear entry gland positions are possible by unbolting and rotating the removable rear cover. 2 Flameproof Alternators CE242 (6) ASX400-401

APPLICATION This product is approved for use in Zone 1, Group IIB, T4 hazardous areas and is designed for use as an engine mounted belt driven alternator. It should NOT be used for other types of application without the prior approval of Chalwyn. A speed signal output is available. Note: The output demand on the alternator is not to exceed the rated 50 amperes. SELECTION At the time of ordering, the following need to be specified :- (a) Whether side entry (ASX-400) or rear entry (ASX-401) cable gland position is required. (b) Pulley selection. Take into account alternator speed range (see page 4 paragraph 2,) as well as belt selection. For latest details of the range of suitable pulleys please contact Chalwyn Sales Dept. Note, if a non-chalwyn pulley is to be fitted, please forward details to Chalwyn for approval. 3 Flameproof Alternators CE242 (6) ASX400-401

INSTALLATION ASX-400 Rear Cover removed to show Terminals Speed Signal (W Terminal) Negative (B- Terminal) Ignition (D+ Terminal) (see note 9) Regulator Positive (B+ Terminal) 1. Remove any existing non flame proof alternator from the diesel engine. 2. Check the alternator drive pulley ratio. In the case of fixed speed applications the pulley drive should be arranged to give a continuous alternator speed of between 4,000 rpm and 6,000 rpm. In the case of variable speed applications the pulley ratio should be selected to give an alternator speed of 2000 to 2,500 rpm at the engine low idle. This typically equates to a normal operating alternator speed range of about 3,000 rpm to 6,000 rpm. MAXIMUM alternator speed should not exceed 7,000 rpm. 3. Inspect original engine mounting arrangement to determine which of the two different brackets supplied with the alternator will give the most suitable mounting of the rear leg. The shorter bracket has a standard SAE J180 inner spacing (approximately 100mm or 4 ) that suits 1/2 mounting bolts. The sliding bush allows for slight variations in the clearance to the original engine casting mount. The wider bracket is designed for engines such as the Caterpillar C9 where the engine mount is behind the rear leg of the bracket. The alternator can be mounted either way up so it should not be necessary to remove the mounting brackets. The unused bracket should be attached to the belt tensioning bar using a long 1/2 bolt and nuts (not supplied) assembled through BOTH legs of the bracket. (See also Special Conditions for Safe Use on page 5). 4. Finalise the position of the cable gland entry by unbolting and rotating the rear cover. Ensure that with the chosen cable entry position and the cable does not snag on any internal component when the alternator rear cover is fitted to the alternator and that the cable can be routed away from the alternator in such a way as to avoid potential mechanical or heat damage. NOTES: CABLE GLAND SUPPLIED WITH ALTERNATOR Gland CG-17 This is intended for use with armoured cable with an inner sheath in the size range 12 to 20.5mm diameter and an outer sheath in the size range 16 to 27.5mm diameter 4 Flameproof Alternators CE242 (6) ASX400-401

5. With the rear cover removed prepare correctly rated cable (10mm 2 conductor section minimum) for fitting to the terminals. Note the B+ and B-terminals are designed for M8 ring connections. The D+ terminal is designed for a M5 ring connection. When slackening or tightening the terminal nuts take care not to slacken the nuts at the base of the terminal posts. Check and tighten these if necessary. If a speed signal is required connect to the W terminal with a M4 ring connection. Again avoid slackening the nut at the base of the post. Use cable ties as appropriate to prevent cable damage. 6. Refit the rear cover after ensuring the O ring seal is undamaged and is properly seated in the seal groove. Torque the rear cover fasteners to 15Nm. 7. Fit alternator to engine. Fit the external earth wire from the M4 tapped hole in the Alternator rear cover to a clean position on the engine as follows. Remove the nut, spring washer and tab washer from the hexagonal terminal post. Use a 4mm 2 section cable and a M4 ring terminal which should be fitted over the terminal stud. Replace the tab washer with the tab orientated towards the rear cover so that it is prevented from rotating by the hexagonal post. Replace the spring washer and nut and tighten securely. NOTE: Check that the engine is also electrically bonded to its base frame or equivalent. 8. Fit an antistatic (conductive) drive belt and check it is correctly tensioned. When using Chalwyn 2 groove or poly V type pulleys it is important that the resulting side force does not exceed 1270 Newtons. 9. The ignition/excitation cable to the Chalwyn alternator (D+ terminal) must be connected via an ignition switch and a warning lamp as in an automotive style arrangement. This warning lamp to illuminate to indicate: a) Engine not running. Ignition (excitation) circuit powered. b) Engine running. Alternator output low (battery discharging). SPECIAL CONDITIONS FOR SAFE USE: a) When finalising the installed position of the alternator ensure that over the range permitted for drive belt adjustment, at no point shall the rotating parts of the alternator come within 5mm. of any item against which rubbing could occur. b) Flamepath gaps within the alternator are smaller than the maximum permitted by EN 60079-1. The flamepath gaps shall not be enlarged during service. c) Output voltage from the alternator is controlled by an internal regulator. It is recommended however that over voltage protection is fitted to any circuit supplied by the alternator in which one or more components could become a potential source of ignition should over voltage occur. OPERATION Operate engine as per a normal diesel engine. ie. Turn ignition on (ignition warning lamp should illuminate). Crank engine and run up to speed (warning lamp should cease to be illuminated). Should ignition warning light illuminate at any time that the engine is running within its normal speed range, the engine must immediately be shut down for alternator, battery and electrical system checks to determine the reasons for the problem. The engine must not be operated again in a hazardous area until the problem has been identified and rectified. 5 Flameproof Alternators CE242 (6) ASX400-401

maintenance Routine maintenance is to be undertaken as follows : MONTHLY - Check drive belt is in serviceable condition and is correctly tensioned. - Check alternator mounting fasteners are tight. - Check alternator cable is properly supported and free from damage. - Check air passages under fan cowl are clear of any significant build up of foreign matter. - Check to ensure good electrical bonding exists between the alternator, engine and engine base frame and,if applicable, the metal braiding of the alternator output armoured cable. THREE MONTHLY - Check end float at alternator cooling fan. This must not exceed 0.2mm when alternator is cold. - Check fan to cowl clearance. At worst point this must be greater than 1.0mm. YEARLY (or each 2,000 hours - whichever occurs sooner) - Remove alternator rear cover. Loosen the two fasteners locating the regulator carefully noting the position of the insulating and steel washers (see diagram under INSTALLATION). Replace regulator and brush assembly with a new assembly ensuring the various washers are replaced correctly and the fasteners are retightened. - Clear any dust from the rear cover area. Check cable condition is acceptable for further service. Check and tighten as necessary all terminals. - Check in turn that each alternator terminal is electrically isolated from the alternator body. - Check rear cover O ring seal is suitable for further service and is properly located in the seal groove. Refit rear cover torqueing fasteners to 15Nm. Tighten cable gland. Maintenance Notes: The M6 socket head cap screws utilised for fastening the end covers must only be replaced by cap screws with a yield strength better or equal to grade 12.9 and standard to the requirements of EN 60079-1:2004. Any maintenance problems not covered by the above routine maintenance schedule should be discussed with your Chalwyn Distributor before any repair work is undertaken. When re-installing the alternator always ensure compliance with the Special Conditions for Safe Use listed on page 5. 6 Flameproof Alternators CE242 (6) ASX400-401

NOTES: 7 Flameproof Alternators CE242 (6) ASX400-401

Chalwyn by AMOT www.chalwyn.com A division of Roper Industries Limited UK Western Way Bury St Edmunds Suffolk, IP33 3SZ Tel: +44 (0)1284 715739 Fax: +44 (0)1284 715747 USA 8824 Fallbrook Drive Houston TX 77064 Tel: +1 281 940 1800 Fax: +1 713 559 9419 Canada 3230 97 Street Edmonton Alberta, T6N 1K4 Tel: +1 780 465 4429 Fax: +1 780 469 6275 Chalwyn's Quality Management System is approved by LRQA. Chalwyn reserves the right to update this PRODUCT specification without prior notice.