TECHNICAL CATALOG NEPTIS INVERS/INVERS-B ELECTRO-MECHANICAL OPERATOR FOR AUTOMATIC SWING DOORS, WITH SINGLE/DOUBLE LEAF

Similar documents
Max. stand-by power without accessories Use frequency 100% Max leaf width Motor Motor powered at 36V with encoder Max.

Sliding Door Automation For escape routes and emergency exit

SWING DOOR OPERATOR for one or two wings

24 V ENCODER SAFE VERSATILE SETTING. Ditec Qik Automatic barriers for passages up to 7.6 m.

SWING DOOR OPERATOR for one or two wings

GENERAL SAFETY WARNINGS page 4 GENERAL SAFETY OBLIGATIONS 4 1) MODEL DESCRIPTION 5 2) TECHNICAL SPECIFICATIONS 5

USER INSTRUCTIONS FOR SLIDING DOORS

Automation systems for swing gates hydraulic

CATALOGUE 2017 AUTOMATIC DOORS

Gilgen FD 20 swing door drive unit

EC DECLARATION OF CONFORMITY

record DFA 127 > Your platform for all automatic swing door applications your global partner for entrance solutions

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Ditec automatic pedestrian sliding doors.

Installation Manual. Door Automation. Leading the way...

SINAMICS GM150 IGCT version

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

Control panel installation manual for 230 V~ automation with one or two motors D5 S5 JT RF ON TC RP TR R1 OM J7. Electric lock. Flashing light.

ED900. Low energy operator. Customizing Features: Book 3 of 3

Automatic Swing door Operator SD3108 Product manual. Notes: please keep the manual properly for reference. Do carefully read this manual before use.

Automatic Sliding Door Retrofit Drive Assembly. Installation Manual DoorControlsUSA.com

SHUTTER D GARAGE & ROLLER SHUTTER

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

Myto BELOWGROUND AND ABOVEGROUND OPERATOR FOR SWING GATES

REVOLVING DOOR AUTOMATIC TWO-WING REVOLVING DOOR

with leaves up to 2 m Kg

PORTEO PORTEO. Weight Configurations Max door weight 100kg. Parameters Max door width 1100mm Max opening angle 110

access

CB-9 CONTROL BOARD INSTRUCTION MANUAL

Gate 1 DG CONTROL UNIT FOR ONE MOTOR DIGITAL PROGRAMMING. Guide to the Product. Gate 2 DG. Control Units. Control Units. Gate 1 DG.

ECONOMISER SERIES E2T USER MANUAL

Olly Dok. automations and motorized tracks for straight sliding frames

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ED50. Low energy automatic swing door operator. Service Manual

Sliding Door WK120. Technicall Information. January 2018

SLIDER AUTOMATIC DOOR TECHNICAL DATA THE ENERGY SAVING TECHNOLOGY OF SLIDER ENERGY SAVING

In-Head Automatic Swing Door Operator DORMA. ED 200i

Operators for sliding doors

EZS. Motorized Linear Slides. Series. RoHS-Compliant

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

Gilgen FD 20 swing door drive unit

Automatic Swing Door Operator DFA 127 IN (Inverse) Operating instructions E

Type of installation. external motor. underground motor. Leaf max length (m) Leaf max length (m) Max leaf weight (kg) V V V

OVER. Automatisms for swinging doors PATENT PENDING

Tourniket. The all round revolving door. Door Systems

Heat Meter Integrator

Ditec PWR Automation system for swing gates with wings up to 5 metres

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

unipark Parking space saver operator for single CAR space. Gearmotors 24 V DC

Compact Sliding Door Operator Dor-O-Matic 2900 Series

ECU1000 ELECTRONIC CONTROL UNIT

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

L /2010 rev 5 MATRIX MATRIX-RE CP.BULL CP.BULL-RI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Amico. new. Above ground operator for swing gates of up to 1.8 m per gate leaf. A new concept in safety

Tourniket. The all round revolving door. Door Systems

EvoDrive AUTOMATIC INTERNAL DOOR

DIGIWAY plus DWPS102S DWPS102A DWPS102U DWPD102SXX DWPD102AXX DWPD102UXX. The installer s choice INSTALLATION, USE AND MAINTENANCE MANUAL ENGLISH

Technology Versatility Practicality

ENGINE PROTECTION BOARD PDM1

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Garage. and Industrial Door Operators. 60 NiceHansa Catalogue NiceHansa Catalogue

Sliding door operator

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

Over Over Evo Over Heavy

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

UNIK2E _ V2 (COMPLETE) UNIK2ESK _ V2 (WITHOUT BOX AND TRANSFORMER)

Tourniket. The all round revolving door. Door Systems. Door Systems

Automation systems for garage doors

EC DECLARATION OF CONFORMITY

Gate & Door Controller with LCD and Intelligent Technology

HD 200. Automatic Sliding Door Operator

Hansa. Sliding Gate. Operators. 10 NiceHansa Catalogue NiceHansa Catalogue

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

RVS-DN Digital Reduced Voltage Motor Starter

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş.

1. WARNINGS CAUTION BEFORE FIRST USE GENERAL NOTE. Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş.

CB CONTROL BOARD INSTRUCTION MANUAL VERSION 1.03 DATE 30/10/2000

940SM-SMD. para la naturaleza 100% papel reciclado. ist umweltfreundlich. 100% Altpapier. papier recyclé 100% pour la nature. recycled paper 100%

TOUCH PLS TOUCHSCREEN PLS A NEW HORIZON IN PROGRAMMABLE LIMIT SWITCHES

Index. 4 DESCRIPTION... p. 5 5 PRELIMINARY CHECKS... p. 5 6 ASSEMBLY... p. 6

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

Automatic Operator for swinging doors

SYSTEMS FOR SLIDING GATES

OPERATOR TROUBLESHOOTING GUIDE

TE2010-GE Instructions manual

pg. 2 Using Sensing Edges in Safety Applications How sensing edges work Understanding the fail-safe concept

SiCan Simple CAN Extension Charger to PacMon

QK SW80 V01_2011 USER MANUAL

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

INSTALLATION INSTRUCTIONS

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

DIESEL Engine Fire Pump Controllers Features

GILGEN FD 20 SWING DOOR DRIVE UNIT

CAM-PTZ-AUT Tracking Module for PTZ Camera Installation & User Manual

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Transcription:

NEPTIS INVERS/INVERS-B ELECTRO-MECHANICAL OPERATOR FOR AUTOMATIC SWING DOORS, WITH SINGLE/DOUBLE LEAF FOR SAFETY EXITS IN SMOKE EXHAUSTION SYSTEMS TECHNICAL CATALOG Automatic Door Solutions

NEPTIS INVERS/INVERS-B

Contents PRODUCT PRESENTATION 4 TECHNICAL SPECIFICATIONS 5 OPERATOR DETAILS 6 MOVEMENT TRANSMISSION ARM 7 MECHANICAL DRAWINGS 8 INPUTS/OUTPUTS 9 DIGITAL PROGRAMMER N-DSEL/I 9 PROGRAM SWITCHES 10 FUNCTIONS AND PARAMETERS 11 ACCESSORIES 13 CERTIFICATIONS 14

Product presentation NEPTIS INVERS NEPTIS INVERS-B (with battery) The operator for Neptis Invers swing doors is used in safety exits and in smoke and heat exhaustion systems. The operator can be installed on automatic pedestrian doors with single or double leaf and is suitable for applications in shopping malls, nursing homes, public places and in all environments where the door must ensure an escape route in case of smoke and power outage. In case of power outage and of alarm from the fire detection system, door opening is ensured by the mechanic energy stored in the opening spring. After opening caused by alarm or power outage, normal operation of the door must be restored by the user through the program switch. The operation of the automatism in the automatic work program occurs by means of the opening controls via buttons or by the activation sensors. During the night lock closed door program, the door can be opened via key buttons or Label radio control. The door may remain locked after closing by installing an electromagnet. In case of power outage, the operator INVERS-B with built-in battery ensures a perfect control of the opening movement with the spring. The battery state is constantly monitored by the electronic control unit. The operation of the door is safe thanks to the use and monitoring of the safety sensors, which stop the movement of the door in case of detection of people or objects. Every aspect that concerns safety, from the encoder control to the forces moving the door, is supervised by the software of the electronic control unit, which has passed the tests required by the standard EN 13849 with particular reference to the analysis of faults on electronic components. The operator Neptis Invers complies with European regulations on safety in the use of automatic pedestrian doors EN 16005. 4

Technical Specifications TECHNICAL SPECIFICATIONS MODELS: NEPTIS INVERS with opening spring NEPTIS INVERS-B with opening spring and built-in battery POWER SUPPLY POWER POWER SUPPLY OF EXTERNAL ACCESSORIES ELECTRIC MOTOR SHAFT OUTLET MAXIMUM TORQUE LEAF MAXIMUM WEIGHT * LEAF MAXIMUM WIDTH * OPERATOR SIZE (LxHxD) DIMENSIONS OF OPERATOR WITH BATTERY (LxHxD) WEIGHT OF NEPTIS INVERS OPERATOR WEIGHT OF NEPTIS INVERS-B OPERATOR PROTECTION CLASS AMBIENT TEMPERATURE FREQUENCY OF USE LIMIT SWITCH AND ANTICRUSH SAFETY REACTION TO OBSTACLES OPENING TIME for 95 CLOSING TIME for 95 PAUSE TIME 115/230Vac +/-10%, 50-60Hz 95W 24Vdc, 1A 24Vdc 45 Nm max. 250 kg (up to 800 mm) max. 1400 mm (up to 100kg) 550 x 110 x 120 mm 730 x 110 x 120 mm 9.5 kg 11 kg IP31-15 C +50 C continuous encoder controlled reversal of direction 3-8 seconds adjustable 6-15 seconds adjustable 0-60 seconds adjustable * THE WEIGHT OF THE LEAF DEPENDS ON WIDTH (see chart in the section MECHANICAL DRAWINGS) AUTOMATISM WITH SPRING OPENING IN CASE OF POWER OUTAGE 5

Operator details COMPONENTS OF THE OPERATOR LEGEND 1 L-NEP logic card 8 spring preload locking screw 2 PWN-T electrical wiring and power supply card 9 plastic plate 3 opening spring 10 transformer 4 spring preload reference line 11 N-BAT module, battery charger card 5 gear motor with encoder 12 wiring between N-BAT module and PWN-T card 6 motion transmission shaft outlet 13 N-BAT module, batteries 7 inner wiring between the L-NEP and PWN-T cards 14 battery cable connection NEPTIS INVERS 5 6 3 1 4 6 2 7 8 9 10 NEPTIS INVERS-B (with battery) 3 7 11 5 1 6 4 2 5 8 14 9 10 12 13 6

Movement transmission arm MODEL CODE DESCRIPTION BSS2FE Steel BSS2FE articulated push arm 7

Mechanical drawings From design to realization... ASSEMBLY OF THE OPERATOR ON THE TRANSOM FROM THE SIDE OPPOSITE TO THE HINGE BSS2 ARTICULATED PUSH ARM The door opens outwards (seen from the operator side) (standard) A X=12.5 mm 261 730 OPERATOR WITH BATTERY MODULE 546 STANDARD OPERATOR CABLE PASSAGE SLOT 23 123 115 115 123 10 B X=36.5 mm 69 40 18.5 A+C X=60.5 mm X 12 41 6 261 220 50 B+C X=84.5 mm A = STANDARD TAPERED PIN Should it be necessary to increase the distance between the operator and the arm (dimension X), replace the standard tapered pin with the following optional extensions: B = EXTB-Z TAPERED PIN (optional) for mm. 24 shaft extension C = EXTC-Z EXTENSION (optional) for TAPERED PIN for mm. 48 shaft extension 261 220 0...250 mm Kg LEAF WEIGHT/WIDTH CHART OPENING DIRECTION 250 For this application, please consider that the gearmotor must be on the hinged side of the door for a correct opening movement direction. It is necessary to install a mechanic lock in open door position. 200 150 1) Usable leaf length and weight Usable leaf length and weight with different fastening dimensions UNUSABLE leaf length and weight 100 mm 0 500 1000 1500 1) Installation drawings available upon request 8

Inputs/Outputs Digital Programmer N-DSEL/I INPUTS / OUTPUTS INPUTS Internal opening radar External opening radar Start for opening command in all automatic programs Open to control opening in the night lock program with closed door Safety opening sensor Safety closing sensor Input for opening command from the fire alarm system OUTPUTS Electric lock Door status DIGITAL PROGRAMMER N-DSEL/I The digital programmer N-DSEL/I is the tool required to set up automatic door operation and perform the set-up and function/parameter setting operations, to carry out system diagnostics and to access the event memory containing information about the automatism and its operation. Access to the programming menu is protected by a technical password, to ensure that only specialised personnel can perform any operation on the automatism. The digital programmer N-DSEL/I can also be used by the end user, but only to select the operating mode of the automatic door; the user can also select a preferred language and set a user password to prevent the use of the digital programmer by unauthorized persons. INFORMATION AREA AND EVENT MEMORY The digital programmer allows to display automation-related information and to access the event memory. The information area allows to display the total number of operations carried out by the door after the commissioning of the operator and the partial number of operations carried out since the last service, as well as information about the automatism, such as the software versions or the serial number of the electronic board. The event memory allows to display the error messages or the system malfunctions; the unit stores the last 5 events in chronological order. 9

Program switches The program switch allows the user to choose the operating mode of the automatic door. It is possible to install one of the following program switches: Manual switch integrated in the side panel of the operator I = Automatic Program, 0 = manual program, II = night lock / open door (selectable) EV-MSEL manual key switch Automatic bi-directional, exit only, manual program, open door, night lock. N-DSEL/I digital programmer Automatic bi-directional, exit only, open door, night lock, manual program, partial opening of just master leaf for double leaf doors. 10

Functions and parameters FUNCTIONS AND PARAMETERS Functions and parameters are programmed by the technical staff with the aid of the digital programmer N-DSEL/I. FUNCTIONS SINGLE/DOUBLE LEAF DOOR OPERATION Using two operators allows to synchronise the operation of double-leaf doors. ELECTRIC LOCK MANAGEMENT The operator is designed to control a 24V electric strike/electromagnet BATTERY MONITORING Should the battery get damaged, the door can either keep operating normally, just signalling the fault, or open and stay like that. MONITORING OF SAFETY SENSORS (complying with standard EN12978) A sensor test is performed every time the door starts moving. STEP-BY-STEP FUNCTION Automatic reclosing disabled; the opening and closing cycle must be controlled by operating the Start or OPEN input. PARTIAL OPENING FUNCTION (for double-leaf doors) In a double-leaf door only the master leaf may be opened. PUSH & GO FUNCTION The automatic opening cycle may be triggered by slightly pushing the leaf. 11

Functions and parameters PARAMETERS ADJUSTMENTS OPENING SPEED CLOSING SPEED PAUSING TIME WITH OPEN DOOR THRUST POWER SLOW-DOWN DISTANCE AT THE END OF THE OPENING AND CLOSING CYCLE WIND STOP, CONTRASTING WIND ACTION POWER/DURATION OF THE MOTOR THRUST AT THE END OF THE CLOSING CYCLE HOLDING TENSION WITH DOOR CLOSED OPENING DELAY AFTER ELECTRIC LOCK ACTIVATION CLOSING STRIKE TO EASE THE RELEASE OF THE ELECTRIC SWITCH 12

Accessories N-DSEL/I Digital programmer for door control. It allows to select all the functions, to set all the parameters (acceleration, speed, distances, etc.), to check the state of all the inputs by means of diagnostic functions and to access the information area. EV-MSEL Mechanic switch to select the work program. OM105L Black two-direction microwave sensor OM106C Black one-direction microwave sensor OA-EDGE-T 340 L safety sensor, 340mm, 1 module, safety test, LH closing* OA-EDGE-T 340 R safety sensor, 340mm, 1 module, safety test, RH closing* OA-EDGE-T 900 L safety sensor, 900mm, 1 module, safety test, LH closing* OA-EDGE-T 900 R safety sensor, 900mm, 1 module, safety test, RH closing* * LH closing or RH closing indicates that the sensor is designed to be installed with the lens bearing the TX mark on the main closing edge (on the side opposite to the pivots). WR5MS MASTER/SLAVE CONNECTION CABLE for double swing door CENTRAL CASING for double wing door, mm 1000 A B A B Pin for shaft extension mm.24 Pin for shaft extension mm.48 FIXPLATE-P Fixing plate for the operator NEPTIS INVERS SPYCO Single-channel transmitter for remote operation EN-RF1 Coupling single-channel radio receiver 13

Certifications CERTIFICATIONS ELECTROMAGNETIC COMPATIBILITY DIRECTIVE "2014/30/EU" Standard EN 61000-6-2 Standard EN 61000-6-3 LOW VOLTAGE DIRECTIVE LVD 2014/35/EU Standard EN 60335-1 Machinery Directive 2006/42/EC Standard EN 13849-1 Standard EN 13849-2 Category=2, PL=d EN 16005 14

15

NEPTIS INVERS/INVERS-B NEPTIS INVERS/INVERS-B TECHNICAL CATALOG - GB - Rel.1.0-10-2016 www.labelspa.com Automatic Door Solutions LABEL S.p.A. - Via Ilariuzzi, 17/a - 43126 San Pancrazio Parmense (PARMA) ITALY - T: +39 0521 6752 - F: +39 0521 675222 - Email: infocom@labelspa.it