Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-PSG3S/3GD

Similar documents
Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-RS4

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AY1X/S1139

UNIVERSAL MAGNETIC FIELD SENSORS FOR PNEUMATIC CYLINDERS. Sense it! Connect it! Bus it! Solve it!

UNIVERSAL MAGNETIC FIELD SENSORS FOR PNEUMATIC CYLINDERS. Sense it! Connect it! Bus it! Solve it!

Rotative measurement Incremental rotary encoder RI-10S10C-2B500-H1181

Rotative measurement Incremental rotary encoder Ri-10S10C-2B5000-H1181

Rotative measurement Incremental rotary encoder Ri-10S10C-2B1000-H1181

Contactless Encoder with Stainless Steel Housing Incremental: ppr RI360P0-EQR24M0- INCRX2-H1181

Rotative measurement Absolute rotary encoder / Multiturn RM-29S10C-9A28B-R3M12

Universal Magnetic Field Sensors

RI360P0-QR24M0- INCRX2-H1181 Contactless Encoder Incremental

Mechanical Kiln Monitoring (MKM) System

Pneumatic cylinders, piston-ø 8 25 mm Single acting DIN ISO 6432

INDUCTIVE SENSORS FOR ROTARY ACTUATORS. Sense it! Connect it! Bus it! Solve it!

Compact cylinders series NYD Double acting with magnetic piston, ISO M5 to G1/8 Piston Ø 20 to 100 mm

CPLab / CP Factory. Application module magazine. Data sheets

Pneumatic cylinders, piston-ø mm Double acting with magnetic piston DIN ISO 15552

Technical Data. Dimensions

INDUCTIVE SENSORS FOR UTILITY VEHICLES. Sense it! Connect it! Bus it! Solve it!

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

MAGNETO-INDUCTIVE POSITION DETECTORS

Pneumatic control unit for decentralized automation of ELEMENT process valves

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

SERIES 54 Inductive Proximity Sensor

Proximity sensors SMT/SME-10, for C-slot

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Cylindrical Inductive Proximity Sensor GX-M SERIES

INSTRUCTION MANUAL (ATEX / IECEx)

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

MGX. 2-jaw parallel self-centering pneumatic gripper series MGX. Parallel grippers. Pinze parallele MGX

Product Overview. Rotary Encoders for Potentially Explosive Atmospheres (ATEX)

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Ex Pressostat EXPK 944/947/953. Applications. Features

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Ex m Solenoid Operator Type 0519

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

switchcontrol The robust opto-electric position indicator

PMS - PKS / PMW - PKW series

Linear actuators DFPI

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

Your Global Automation Partner. LTX Linear Position Sensors with SSI Interface. Operating instructions

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

UNI EN ISO EN

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

INSTRUCTION MANUAL (ATEX / IECEx)

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Alarm contacts for pressure gauges and thermometers

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

OPERATING INSTRUCTIONS

OPTISWITCH 6500 C Technical Datasheet

Solenoid valves VUVS/valve manifold VTUS, NPT

Normally-open. Normally-open

Control block VOFA with safety function

Type Code Connection and Extension Cables M8

Product specification

YFC. Limit switch. Ex d. 24 operating head types

Direct-acting 3/2 way plunger valve

Operating Instructions

Flow sensors. 324 Hans Turck GmbH & Co. KG Tel Fax

SERIES 54 PROXIMITY SENSORS

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Category II 1 G only applies to the Constructional Variants shown in table 15.2 of annex 1.

Explosion-Protected Pressure Switches

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Product specification

Pressure switch hex 27

ExBin-P Pressure switches 5 Pa Pa

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

HV Gate Valve with pneumatic actuator

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Temposonics. E-Series Analog + Start / Stop. Magnetostrictive Position Sensors. Temposonics EP Measuring range mm / mm SENSORS

Operating Instructions

OPTISWITCH 6500 C Technical Datasheet

Temposonics. M-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

Operating instructions Solenoid interlock EX-AZM About this document. Content

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

3/2 and 4/2 directional seat valves with solenoid actuation

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Capacitive Sensors. Series 80 - PNP

Sentronic PLUS 614 Series

Barrel Size Metal Barrel Plastic Barrel. 5 Nm (3.7 ft-lb) 10 Nm (7.4 ft-lb) 15 Nm (11 ft-lb) 25 Nm (18 ft-lb) 90 Nm (66 ft-lb) 90 Nm (66 ft-lb)

Proportional Solenoid for Hydraulics ATEX + IECEX

Operating Instructions. Angle Seat Control Valve. Type 7020

DIAMOND POINT VIBRATING PROBES

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

Type Electronic Limit Switch

Differential pressure gauge Model , copper alloy Model , stainless steel version

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Solenoid coils VACF Type codes

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Transcription:

ATEX category II 3 G, Ex zone 2 ATEX category II 3 D, Ex zone 22 For T-groove cylinders without mounting accessories Optional accessories for mounting on other cylindrical housings. One-hand mounting possible Fine adjustment tool and stopper directly mountable on the sensor Stable mounting Magneto-resistive sensor DC 3-wire, 10 30 VDC NO contact, PNP output Type designation Ident no. 4685865 Pass speed ð 10 m/s Repeatability ð ± 0.1 mm Temperature drift ð 0.1 mm Hysteresis ð 1 mm Ambient temperature -25 +70 C For explosion hazardous areas see instruction leaflet Pigtail with male end, Ø 8 mm Wiring Diagram Operating voltage Residual ripple DC rated operational current No-load current I 0 Residual current Isolation test voltage Short-circuit protection Voltage drop at I e Wire breakage/reverse polarity protection Output function Switching frequency 10 30 VDC ð 10 % U ss ð 150 ma ð 15 ma ð 0.1 ma ð 0.5 kv yes/ Cyclic ð 1.8 V yes/ Complete 3-wire, NO contact, PNP 1 khz Functional principle Magnetic field sensors are activated by magnetic fields and are used, in particular, for the detection of the piston position in pneumatic cylinders. As magnetic fields can permeate non-magnetizable metals, they detect a permanent magnet attached to the piston through the aluminium cylinder wall. Approval acc. to ATEX declaration of conformity TURCK Ex-07001M X Design Rectangular,UNT Dimensions 28 x 5 x 6 mm Housing material Plastic, PP Active area material Plastic, PP Tightening torque fixing screw 0.4 Nm Electrical connection Cable with connector, M8 1 Cable quality 3 mm, Gray, Lif9Y-11Y, PUR, 0.3m Suited for E-ChainSystems acc. to manufacturers declaration H1063M Cable cross section 3 x 0.14 mm 2 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 2283 years acc. to SN 29500 (Ed. 99) 40 C Packaging unit 1 Mounting on the following profiles. Cylindrical design E N K F Switching state Included in delivery LED,Yellow cable clip, SC-M8/3GD 1 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Mounting instructions/description Mounting instructions Thanks to the mounting lip, the sensor can be inserted into the groove from above with one hand. Mount the sensors as follows using the patented wing screw: The wing screw and the female thread feature a lefthand thread. Two small plastic lips keep the screw in position, ready-to-install. Turn the screw clockwise. The screw moves out of the thread and hits the upper grooves with the wings. The sensor is thus pressed down and locked in position. A few degrees up to approximately 1.5 turns of the screw with a slotted screwdriver (blade width 0.5 mm) or a 1.5 mm Allen key are sufficient to ensure vibration-proof fastening, depending on the shape of the slot. A tightening torque of 0.4 Nm is sufficient for safe mounting without damaging the cylinder. The sensor can now withstand an axial and radial tensile load of F=100N applied on the cable. A cable clip is included in the scope of delivery. It enables smooth cable routing in the groove and ensures that the cable is fastened as securely as possible. The corresponding accessories for mounting on other cylindrical housings must be ordered separately. 2 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories Type code Ident no. Description KLZ1-INT 6970410 Accessories for mounting the sensors BIM-INT and BIM-UNT on tie-rod cylinders; Cylinder diameter: 32 40 mm; material: Aluminium; Further mounting accessories for other cylinder diameters on request KLZ2-INT 6970411 Accessories for mounting the sensors BIM-INT and BIM-UNT on tie-rod cylinders; Cylinder diameter: 50 63 mm; material: Aluminium; Further mounting accessories for other cylinder diameters on request UNT-STOPPER 4685751 Accessories for finetuning the switchpoint on N T-groove cylinders; snap-locked in the BIM-UNT fixture; suited for multiple use; material: plastic UNT-JUSTAGE 4685750 Accessories for finetuning the switchpoint on N T-groove cylinders; snap-locked in the BIM-UNT fixture; suited for multiple use; material: metal/plastic KLRC-UNT1 6970626 Accessories for mounting on E cylinders; diameter: 8 25 mm; material: PA 6I/6T / nickel silver; Fire-hazard classification acc. to UL94 - V2 3 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories Type code Ident no. Description KLRC-UNT2 6970627 Accessories for mounting on E cylinders; diameter: 25 63 mm; material: PA 6I/6T / nickel silver; Fire-hazard classification acc. to UL94 - V2 KLRC-UNT3 6970628 Accessories for mounting the BIM-UNT sensor on E round cylinders; diameter: 63 130 mm; material: PA 6I/6T / nickel silver; Fire-hazard classification acc. to UL94 - V2 KLRC-UNT4 6970629 Accessories for mounting the BIM-UNT sensor on E round cylinders; diameter: 130 250 mm; material: PA 6I/6T / nickel silver; Fire-hazard classification acc. to UL94 - V2 KLDT-UNT2 6913351 Accessories for mounting the BIM-UNT sensor on dovetail cylinders; groove width: 7 mm; material: PPS KLDT-UNT3 6913352 Accessories for mounting the BIM-UNT sensor on K dovetail groove cylinders; groove width: 9.4 mm; material: PPS 4 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories Type code Ident no. Description KLDT-UNT6 6913355 Accessories for mounting on K dovetail groove cylinders; groove width: 7.35 mm; material: PPS 5 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Operating manual Intended use This device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas according to EN60079-0:2012/A11:2013, EN60079-15:2010 and EN60079-31:2014. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 3 G and II 3 D (Group II, Category 3 G, electrical equipment for gaseous atmospheres and category 3 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) É II 3 G Ex na IIC T4 Gc/II 3 D Ex tc IIIC T110 C Dc Local admissible ambient temperature -25 +55 C Installation/Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before inserting the cable or opening the cable socket. Special conditions for safe operation For devices with M8 connectors please use the supplied safety clip SC-M8/3GD. Do not disconnect the plug-in connection or cable under voltage. Please attach a warning label permanently in an appropriate fashion in close proximity to the plug-in connection with the following inscription: Nicht unter Spannung trennen / Do not separate when energized. The device must be protected against any kind of mechanical damage and degrading UV-radiation. This is achieved through mounting in a standard T groove of a pneumatic cylinder. Load voltage and operating voltage of this equipment must be supplied from power supplies with safe isolation (IEC 30 364/UL508), to ensure that the rated voltage of the equipment (24 VDC +20% = 28.8 VDC) is never exceeded by more than 40%. Service/Maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed. 6 / 6 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com