Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Similar documents
Lumination TM LED Luminaires LAL Series - Continuous Run Option

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Lumination TM LED Luminaire (IS Series)

Wet Rated Batten LED Luminaire

Horticulture Batten LED Luminaire

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

WARNING / AVERTISSEMENT

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

MOONRING 1.5 MOONRING 3

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

Lumination TM LED Luminaire LUR Series

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

Cable Cubby 1202 and 1402 Installation Guide

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

Spun Bay Installation Standard Version (non dimmable), Hook Mount

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

Retractor SM Installation Guide

960 Montage sur staff préfabriqué Mounting in prefabricated plaster

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

LED Utility Wrap Fixture

LED Recessed Troffer Retrofit Kit

Cable Cubby 650 UT Installation Guide

Specification Grade Contemporary Wall Mount/Technical Installation Data

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

Cable Cubby 1200 and 1400 Installation Guide

Installation Instructions 4 Gravity Enhanced Color Adjustable

Installation Instructions

Captivate Illuminated Mirror Light

Cable Cubby 500 and 700 Installation Guide

VWM SERIES U L R. Instruction Sheet. Vertical Wall Mount Rack LISTED

INSTALLATION INSTRUCTION Bollard Light 12V

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Installation Instructions

Installation Instructions

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

I. Pendant Mount Installation

MAXLITE RKT LED Retrofit Kit

IMMERSION. GE Lighting. OEM Installation Guide. imagination at work. LED Display Lighting

Parent s Guide. This guide contains important information. Please keep it for future reference US

Installation Instructions

Installation Instructions

Installation Instructions

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

HBDBM High Bay Series

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

UB-2 2 Universal Button

LAL SERIES LED LUMINAIRE

Installation Instructions

BEAM SPREAD NR = Narrow (36 degree) WD = Wide (56 degree) WW 2 = Wall Wash. REFLECTOR FINISH SD = Semi- Diffused

High Bay Luminaire Series

SF 10C SUB Subwoofer Setup Guide

RSA-MRZ Installation Instructions

Letter Band Phonics Jam

VR44-MU-xxx-8yy-xxxxA

RSA-MRZ Installation Instructions

GETTING STARTED WITH IN-WALL DIMMER SWITCH

Learn & Discover Driver TM

Go! Go! Smart Friends

VR44-MU-xxx-8yy-xxxxA

classic white Refined minimalism

Parent s Guide Mickey Ramps Fun House

100A 225A 400A PATENT PENDING

Parent s Guide Mickey Choo-Choo Express

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

Installation Instructions

SOLA SM and SOLA SM 365 Light Engine Instruction Manual

VR22-MU-xxx-8yy-xxxxA

Bear s Baby Laptop TM

MEDMASTER DOWNLIGHT Luminaires for MRI Applications

Installation Instructions

User s Manual ATTILA THE ANKYLOSAURUS TM VTech Printed in China US

Installation Instructions MX LED Enhanced Color Adjustable

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

2-WAY REMOTE STARTING SYSTEM WITH 1 BUTTONS FOR AUTOMATIC TRANSMISSION RED301-2WAY / ANT-2WDSS. User Guide For Key

Certification Exhibit FCC ID: SK9OW1 IC: 864G-OW1. FCC Rule Part: IC Radio Standards Specification: RSS-247. ACS Project Number:


Instruction Sheet ERK-XXXXKD SERIES KNOCKDOWN STANDALONE RACK

Lumination LED Luminaires

BT300 Variable Frequency Drive Bypass

User s Manual VTech Printed In China US CA Manual new.indd /6/6 10:41:57

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

AF7006 Alarming Camera Display Unit (6.5 ) AF7015 Alarming Camera Display Unit (4.5") AF7216 Camera Sensor

UHC-202 Hardware Guide

ECO-T LED RECESSED TROFFER USER MANUAL

Installation Instruction

Fan Relay Board (FRBii) Assembly

INSTALLATION GUIDE Works in double and single ended wiring.

QTM-eLED INSTALLATION INSTRUCTIONS Must be installed by licensed electrician.

Verax 75 and Verax VPA Installation Manual

User s Manual. Deluxe Car Carrier TM VTech Printed in China

Transcription:

Installation Guide Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame BEFORE YOU BEGIN Read these instructions completely and carefully. RISK OF ELECTRIC SHOCK Turn power off before inspection, installation or removal. Properly ground electrical enclosure. RISK OF FIRE Follow all NEC and local codes. Use only UL approved wire for input/output connections. Minimum size 18 AWG or 14 AWG for continuous runs. WARNING/AVERTISSEMENT RISQUES DE DÉCHARGES ÉLECTRIQUES Coupez l alimentation avant d inspecter, installer ou déplacer le luminaire. Assurez-vous de correctement mettre à la terre le boîtier d alimentation électrique. RISQUES D INCENDIE Respectez tous les codes NEC et codes locaux. N utilisez que des fils approuvés par UL pour les entrées/sorties de connexion. Taille minimum 18 AWG ou 14 AWG pour les rangées continues. NOTICE Lamp Housings RC6, RC8 or LRC6, LRC8 or RX6, RX8 or LRXR4, LRXR6, LRXR8 may be assembled with part FRAMExR. When Lamp Housings RC6, RC8 or LRC6, LRC8 or RX6, RX8 or LRXR4, LRXR6, LRXR8 is assembled with Part FRAMExR the final assembly complies with UL 1598 category IFAO recessed luminaire requirements. LRX products are suitable for wet location covered ceiling only. Les boîtiers de lampes RC6, RC8 ou LRC6, LRC8 ou RX6, RX8 ou LRXR4, LRXR6, LRXR8 peuvent être montés avec la pièce FRAMExR. Lorsque les boîtiers des lampes RC6, RC8 ou LRC6, LRC8 ou RX6, RX8 ou LRXR4, LRXR6, LRXR8 sont montés avec la pièce FRAMExR, le montage final respecte les exigences des luminaires encastrés de la catégorie IFAO de la norme UL 1598. LRX produits conviennent pour emplacement humide couverte au plafond uniquement. Save These Instructions Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Prepare Electrical Wiring Electrical Requirements The LED luminaire must be connected to the mains supply according to its ratings on the product label. Grounding Instructions The grounding and bonding of the overall system shall be done in accordance to local electric code of the country where the luminaire is installed. 1

Components 1 2 3 4 5 Provided Item Qty. 1 Frame (4-inch, 6-inch or 8-inch) 1 2 Mounting brackets 2 3 L-Bracket 2 4 U-Bracket (used only with RC/LRC Series Installs) 1 5 Wing nut 3 NOTE: Part 4 and 5 are only for RC/LRC product. Frame Installation Fixture Diameter LRXR4 RC6/LRC6 RX6/LRXR6 RC8/LRC8 RX8/LRXR8 Hole Diameter 4.9 5.2 in. 6.4 7.2 in. 5.91 6.60 in. 7.5 8.9 in. 7.68 8.27 in. Mounting brackets L-brackets 1 Cut the appropriate size 2 hole into ceiling tile. Place side L-brackets on existing frame screws and tighten with screwdriver on both sides of the frame. Then attach mounting brackets to both L-brackets with wing nuts (provided). 3 Slide hanger bars through adjustable mounting brackets. Adjust height and tighten wing nut Bars A Conduit B 4 Option A: Mount fixture by attaching hanger bars to T-Grid ceiling (BH3 SKU 94890). Option B: Mount fixture with ½ EMT conduit. Note: Supplied by 3rd party. 5 Adjust fixture height to be flush with ceiling and tighten both mounting bracket wing nuts. 2

RC/LRC-Series Mounting (RX-Series Mounting skip to step 15. LRXR-Series Mounting skip to step 18) Through Wiring for RC-series 15A Circuit Maximum Number of Fixtures Lumen Level (120V Input / 277V Input) 1000 84 / 195 1500 77 / 179 2000 59 / 138 3000 38 / 89 4000 24 / 57 Minimum Spacing Requirements for all Fixture Configurations Center to center of adjacent luminaires 24 Top of Luminaire to overhead building member 3 Luminaire center to side building member 12 (For any other information refer to RC-series or LRC-series Installation Guides) Remove cover Screwdriver tip AC conduit Remove AC wires 6 Open RC or LRC PSU box cover, disconnect AC conduit. Remove AC conduit wire from PSU box knockout hole using flat head screw driver. AC line (Line, Neutral and Ground) LRC Wiring Diagram Black /Red (+) Lead TPC White (-) Lead Blue (+) Lead L N G PSU Enclosure White (-) Lead Black (+) Lead *NOTE: Black Lead - 120V ONLY Red Lead - 277V ONLY (0-10V) Purple (+) Dimming Lead (0-10V) Grey (-) Dimming Lead DRIVER 7 Insert AC line wires into the PSU box through the knockout hole and connect wires (see wiring diagrams at right). RC Wiring Diagram Black (+) Lead TPC White (-) Lead *Blue/Red (+) Lead L N G PSU Enclosure Black (+) Lead *NOTE: Blue Lead - 120V ONLY Red Lead - 277V ONLY (0-10V) Purple (+) Dimming Lead (0-10V) Grey (-) Dimming Lead DRIVER 3

Loop around L-bracket Wing nut U-bracket 8 Place PSU box onto frame next to unused junction 9 box and secure with U-bracket by tightening wing nut. Take the provided safety tether and loop one end of the tether around the L-bracket. Safety tether Feed button stop and toggle through hole in bracket Toggle Button stop Connect two quick connects Assembled connector housing 10 Attach the other end of the safety tether to the fixture using one of the three holes located on the fixture brackets. Feed the button stop and toggle through the hole and slide into the hole in the bracket. Allow the fixture to hang freely. 11 Plug together the light fixture to the driver enclosure with the supplied quick connects and assemble the connector housing when finished. Position fixture so L-bracket does not interfere with springs 12 Cut cable tie on light fixture. 13 Align the fixture so that two of the three springs are on each side of the L-bracket. This is necessary in order to make sure that when the springs release, the L-bracket does not interfere and prevent the springs from making contact with the top of the ceiling for proper support. 4

14 Final installation position for springs Push fixture through the hole in the ceiling. This will engage the protruding arms, thus, releasing the springs. The springs will draw the fixture up into the ceiling and hold it their tightly. CAUTION RISK OF PERSONAL INJURY - Operators shall ensure no appendages are in the path of the torsion springs as they are a pinch hazard when released. The springs will release when the arm is flexed downward. Be cautious that no body part is in the path of the spring when released. RISQUE DE BLESSURE CORPORELLE - Les techniciens veilleront à ce qu aucun appendice ne se trouve sur le chemin des ressorts de torsion, car ils présentent un risque de pincement lorsqu ils sont libérés. Les ressorts seront libérés au moment de fléchir le bras vers le bas. Faites attention à ce qu aucune partie du corps ne se trouve sur le chemin du ressort à sa libération. RX-Series Mounting Wiring Diagram Line (black) Neutral (white) Ground (green) Black White DRIVER Green/Yellow AC line 15 Connect AC line to existing junction box. Connect conduit fitting to the existing junction box. Connect the black, white and green/yellow wires of the input leads to the black, white and green AC line wires using UL Listed twist-on wire connectors and close the junction box (see wiring diagram). Springs up Connect plugs Reassembled connector box 16 Connect the two quick connectors and reassemble the connector box. 17 Load springs into upright position by twisting the springs upward and carefully insert the fixture to the hole of the frame. Ensure fixture is secure. CAUTION RISK OF PERSONAL INJURY - Operators shall ensure no appendages are in the path of the torsion springs as they are a pinch hazard when released. The springs will release when the arm is flexed downward. Be cautious that no body part is in the path of the spring when released. RISQUE DE BLESSURE CORPORELLE - Les techniciens veilleront à ce qu aucun appendice ne se trouve sur le chemin des ressorts de torsion, car ils présentent un risque de pincement lorsqu ils sont libérés. Les ressorts seront libérés au moment de fléchir le bras vers le bas. Faites attention à ce qu aucune partie du corps ne se trouve sur le chemin du ressort à sa libération. 5

LRX-Series Mounting Wiring Diagram L Black N White Dimming + Dimming Violet Gray LRX Fixture AC line Ground Green/Yellow 18 Connect conduit end with input leads to existing junction box and make proper connections. Connect the black, white, and green/yellow wires of the input leads to the black, white and green wires using twiston wire connectors and close junction box. Optional dimmer: When connecting with dimming controller, wires must be run through another separate knockout hole. Connect the violet (dimming +) and gray (dimming -) wires to the violet and gray wires of the fixture. 0-10 Volt Dimming LED Driver Gray Violet 0-10V 0-10V + To 0-10V Dimmer NOTE: Please cover dimming leads with wire nuts if you won t connect with dimming leads. Dimming compatibility for both 0-10V and phase cut, please refer to GE website: www.gelighting.com/dimming. Lumens Setting Switch NOTE: For 1000/650lm and 4000/3000lm, default output lumen is 1000lm and 4000lm respectively. Push switch up or left to activate 650lm and 3000lm respectively. 6

Springs up Connect plugs: 3 pole to 3 pole 2 pole to 2 pole Reassemble connector box 19 Connect the two quick connectors and 20 reassemble the connector box. Load springs into upright position by twisting the springs upward and carefully insert the fixture to the hole of the frame. Verify reflector trim is flush with ceiling. CAUTION RISK OF PERSONAL INJURY - Operators shall ensure no appendages are in the path of the torsion springs as they are a pinch hazard when released. The springs will release when the arm is flexed downward. Be cautious that no body part is in the path of the spring when released. RISQUE DE BLESSURE CORPORELLE - Les techniciens veilleront à ce qu aucun appendice ne se trouve sur le chemin des ressorts de torsion, car ils présentent un risque de pincement lorsqu ils sont libérés. Les ressorts seront libérés au moment de fléchir le bras vers le bas. Faites attention à ce qu aucune partie du corps ne se trouve sur le chemin du ressort à sa libération. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAN ICES-005 (A) / NMB-005 (A). Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. All trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. Current, powered by GE is a business of the General Electric Company. 2018 GE. www.currentbyge.com IND259 (Rev 08/15/18) GE2029-8519