GQW1400V. 1MWe TWINGEN in container 20 HC

Similar documents
GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW-705V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS - 600V 06/05/2016 GMS - 600V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW415V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW555V. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW570M. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW870M. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS-110V. Power Rating Standby power LTP kva Standby power LTP kw Prime power PRP kva Prime power PRP kw 81.14

GSW275V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW145V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW415P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GSW170I. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMR - 67P 67P 09/05/2016 GMR - 067P

GSW145I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW80I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW275P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

P6000s 230V 50Hz #CONN #DPP

P V 50HZ #CONN #DPP

THE COMPLETE PETROL PACKAGE

GQW1400V Product Guide

GAS MODEL SERIES: HFGE/O 16.5kW 60Hz FUEL: Propane (Natural Gas) PRIME MOVER: Ford TSG 416

MSW Series P. Main applications: Construction Mobile Workshop Emergency stand-by (residential / industry) Island/Mains synchro (from 100kVA)

1 / Genset general description

Rating Definitions and Conditions

1 / Genset general description

1 / Genset general description

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Rating Definitions and Conditions

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

Diesel generator set QSX15 series engine

S V50HZ #AVR #CONN #DPP

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

Diesel generator set QSX15 series engine

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

DIESEL GENERATOR SET MTU 16V2000 DS1100

Diesel generator set QSK50 series engine

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous

GE.VO.360/325.SS+0_all

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

DIESEL GENERATOR SET MTU 16V2000 DS KVA

DIESEL GENERATOR SET MTU 16V2000 DS1000

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

DIESEL GENERATOR SET MTU 18V2000 DS1400

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

Diesel generator set QSK23 series engine

RENTAL DIESEL GENERATOR SET

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

GE.PK.022/020.SS+0_all

Diesel generator set 6BT5.9 series engine

Diesel generator set QSK23 series engine

DIESEL GENERATOR SET MTU 20V4000 DS3600

Diesel generator set QSB7 series engine

DIESEL GENERATOR SET MTU 12V1600 DS660

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

Perkins 1006TG2A diesel engine Mecc Alte ECP34-2S/4 alternator Standard Generator Features

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

Model NA 2 L

DIESEL GENERATOR SET MTU 20V4000 DS4000

DIESEL GENERATOR SET MTU 12V4000 DS2250

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1

Rental Power QSB7 series engine

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

DIESEL GENERATOR SET MTU 12V4000 DS1750

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

Better Soundproof, Better Life!

The GRW Series Designed for rental businesses POWER FOR RENT

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 12V4000 DS1650

45 KW / 55 KVA POWERED by

Diesel generator set QSK78 series engine

CUKUROVA GENERATOR SYSTEMS

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENERATOR SET MTU 16V4000 DS2250

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

kva kw kva kw N/A K.U.N.Z. Handels-&Produktions GmbH

Transcription:

GQW1400V 1MWe TWINGEN in container 20 HC Pramac TWINGEN system designed and engineered to work in a wide variety of applications where high power, modular and safe supply is needed. Power Rating Frequency Hz 50 Voltage V 400 Phases 3 Standby power LTP kva 1394 Standby power LTP kw 1114 Prime power PRP kva 1252 Prime power PRP kw 1000 Dual Frequency Switch 50/60Hz Frequency Hz 60 Voltage V 480 Phase 3 Standby power LTP kva 1562 Standby power LTP kw 1250 Prime power PRP kva 1436 Prime power PRP kw 1140 Ratings definition (According to standard ISO8528 1:2005) PRP - Prime Power: It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power. LTP - Limited-Time running Power: It is defined as the maximum power available, under the agreed operating conditions, for which the generating set is capable of delivering for up to 500 h of operation per year (whose no more than 300 for continuative use) with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. No overload capability is available.

TWINGEN PACKAGE A. 20 HQ SOUNDPROOF CONTAINER: Soundproof and weatherproof 20 feet High Cube container with proper insulation and openings for twingen service and maintenance B. GENSETS: Two gensets placed inside the container assembled on a skid base without radiator C. COOLING SYSTEM: Complete with two remote electrical radiators (one for each genset) D. FUEL SYSTEM: Complete with double wall metal fuel tank (for both gensets) E. AIR FILTER: Heavy-duty air filters F. COMMAND AND CONTROL PANEL: Single automatic synchronizing control panel to run one or both gensets according to power demand G. EXAUST SILENCERS: Integrated with high insulation

Engine specifications Engine manufacturer Volvo Model TWD1643GE Engine cooling system Water Nr. of cylinder and disposition 6 in line Displacement cm³ 16120 Aspiration Turbocharged Speed governor Electronic Fan Electric Lube oil consumption @ PRP (max) % 0.1 Coolant capacity l 60 Electric circuit V 24 VERSION SWITCHABLE [50/60Hz] YES ENGINE DATA Hz 50 [50Hz] Operating Speed-Nominal rpm 1500 [50Hz] Exhaust emission level Stage IIIA [50Hz] Specific fuel consumption @ 75% PRP g/kwh 196 [50Hz] Specific fuel consumption @ 100% PRP g/kwh 199 ENGINE DATA Hz 60 [60Hz] Operating Speed-Nominal rpm 1800 [60Hz] Exhaust emission optimized for EPA tier (EPA) Tier 3 [60Hz] Specific fuel consumption @ 75% PRP g/kwh 197 [60Hz] Specific fuel consumption @ 100% PRP g/kwh 202 Engine and block Optimized cast iron cylinder block with optimum distribution of forces Wet, replaceable cylinder liners Crankshaft induction hardened bearing surfaces and fillets with seven bearings for moderate load on main and high-end bearings Keystone top compression rings for long service life Replaceable valve guides and valve seats Tapered connecting rods for increased piston lifetime Overhead camshaft and four valves per cylinder Hot parts protection with metal grids Heavy-duty air filters Fuel system Electronic unit injectors Fuel prefilter with water separator and watering-fuel indicator / alarm Fine fuel filter with manual feed pump and fuel pressure switch Lubrication system Full flow oil cooler Full flow disposable spin-on oil filter, for extra high filtration Gear type lubricating oil pump, gear driven by the transmission Cooling system Efficient cooling with accurate coolant control through a water distribution duct in the cylinder block. Reliable sleeve thermostat with minimum pressure drop Belt driven coolant pump with high degree of efficiency

Alternator Specifications Alternator Mecc Alte Model ECO40 2L Type Brushless Class H IP protection 23 Poles 4 Winding leads 12 Voltage regulation system Electronic Standard AVR DSR Voltage tolerance % 1 Mechanical structure Robust mechanical structure which permits easy access to the connections and components during routine maintenance check-ups. Voltage regulator Voltage regulation with DER 1. The digital DER 1 is a Digital controlled regulator, based on DSP (Digital Signal Processor) that combines function as Voltage Regulation and Alternator Protections and Diagnostic into a very small single board. Voltage supply: 40Vac 270Vac Maximum continuous output current: 4Adc Frequency range: 12Hz 72Hz Single phase sensing automatic recognition Average value of voltage regulation Voltage regulation range (sensing) from 75Vac to 300Vac Precision of voltage regulation: ± 1% from no-load to nominal load in static condition, with any power factor and for frequency variations ranging from -5% to +20% of the nominal value. Precision of voltage regulation: ± 0,5% in stabilized conditions (load, temperature). Transient voltage drop and overvoltage within ± 15% Voltage recovery time within ± 3% of the value set, in less than 300 msec. Underspeed protection with adjustable threshold and slope Overvoltage and undervoltage alarms Excitation overcurrent protection with delayed intervention Allarm conditions storage (type of alarm, number of events, duration of the last event, total time) Memorization of the regulator operation time Windings / Excitation system Generator stator is wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th ) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches. MAUX (Standard): The MAUX MeccAlte Auxiliary Winding is a separate winding within the main stators that feeds the regulator. This winding enables to take an overload of 300% forced current (short circuit maintenance) for 20 seconds. This is ideal for motor starting requirements. PMAUX (optional): Alternator can be equipped with the optional PMAUX (Permanent Magnet Generator) which matches the performance and is capable of supporting both linear and distorted loads. Insulation / Impregnation Insulation is of class H standard. Impregnation is made with premium tropicalised epoxy resins by dipping and dripping. High voltage parts are impregnated by vacuum, so the insulation level is always very good. In the high-power models, the stator windings undergo a second insulation process. Grey protection is applied on the main and exciter stator to give enhanced protection. Reference standards Alternator manufactured according to, and complies with, the most common specification such as CEI 2-3, IEC 34-1, EN 60034-1, VDE 0530, BS 4999-5000, CAN/CSA-C22.2 No14-95-No100-95.

Genset Equipment Container 20 feet High Cube High structural resistance ISO lifting hooks CSC SAFETY APPROVAL Double seal gaskets Roof access ladder roof security anchorage points Leak proof basement with double leak detection system Double draining Aspiration: available with standard aspiration or with sand trap filter (optional). Internal canopy lighting system with manual switch for easy operation even with low ambient light conditions. Hot part and rotating part protection. Coolin system The cooling system includes n 2 electro-fans mounted on a common monobloc support, main features of the system: N 2 Electrical Motors Siemens with PTC thermal sensor and oversized shaft bearing (2x30kW, 26KW certificated up to 55 C) Double water circuit (LT and HT) Fan profile optimized for greater efficiency Metal water piping with draining valves Thermal sensor on engine hot water outlet Easy control (front doors) and refiling (from roof) The cooling system fans speed can be controlled by inverter (optional) Exaust System Exhaust thermal insulation: Each silencers is equipped of a double insulation to limit the increase of temperature inside the container. Insulated exhaust piping form engine exhaust manifold to exhaust silencer. Flexible exhaust compensator (one for each engine) Efficient roof fixed exhaust silencers rectangular type (one for each engine) Rain flaps on container roof Fuel system Fuel tank integrated Double wall Metal (weld sealing certificated) Leak detection system External refiling cap under lockable panel Quick fuel connectors for external fuel tank Easy extraction from container without disassembly of other element Water Separator Filter RACOR (n.1 common filter for two gensets) Heavy-Duty air Filters Donalson (N.2 - One for each genset) Battery 4 Optima battery 75Ah/12V/975A with manual battery switch. Easy and Fast Service & Maintenance TWINGEN designed for easy inspection, service and maintenance through inspection doors and panels. Each macro element is easily removable for extraordinary maintenance if needed: Generators Fuel tank Cooling system Control panel

MPP - Modular Parallel Panel The Twingen unit is equipped with an automatic synchronizing control panel that allow work with one or two gensets according to the load demand. The control panel is set on a rear side with dedicated access doors to each section, which are: 1. CONTROL SECTION 2. POWER SECTION 3. OUTPUT POWER SECTION 1. CONTROL SECTION It integrates all control and command devices such as: ON/OFF selector switch Comap Inteligen BaseBox control unit + InteliVision 5 Display (one for each genset) Master genset selector switch (G1 G2) Power Management selector switch (On-Off), in order to start/stop the gensets according to load demand with set parameters on the control units Mechanical hour counter (one for each genset) Fuel level gauge 5A Battery charger (one for each genset) Emergency push-button Eart fault current with selector switch Possible to synchronize up to n 16 Twingen units. 2. POWER SECTION It includes: N 2 four poles motorized moulded case circuit breaker suitably rated with thermal and magnetic overloads (one for each genset). 3. OUTPUT POWER SECTION: OUTPUT POWER Common bus bar suitably rate Multi-pin connector IN and OUT for parallel with other gensets INPUT Plug for auxiliary power supply Supplements available on request: Socket Kit Power lock

Dimensional data Length (L) mm 6060 Width (W) mm 2438 Height (H) mm 3095 Dry weight Kg 15500 Fuel tank material Metal Fuel tank capacity l 1800 Autonomy [50Hz] Fuel consumption @ 75% PRP l/h 195.72 [50Hz] Fuel consumption @ 100% PRP l/h 261.37 [50hz] Running time @ 75% PRP h 9.20 [50Hz] Running time @ 100% PRP h 6.89 [60Hz] Fuel consumption @ 75% PRP l/h 218.63 [60Hz] Fuel consumption @ 100% PRP l/h 295.32 [60hz] Running time @ 75% PRP h 8.23 [60Hz] Running time @ 100% PRP h 6.10 Noise level 50Hz Guaranteed noise level (LWA) db(a) 105 Noise pressure level @ 1 mt db(a) 84 Noise pressure level @ 7 mt db(a) 75

GENSET EQUIPMENT - Options Available: TWINGEN TROPICAL VERSION (with variable speed fans) TRV Pre-heating system PHS Automatic Fuel Pump AFP Sand Trap SAF Kit with n.3 Water Separator Filter (Racor) RWS Different Canopy Colour DCC CONTROL PANEL - Options Available: Control section internal lighting (automatic with door switch) CLS Engine Analogue Gauges EAG Differential Protection type B ADI-B Insulation Monitoring Device (Replace standard differential protection) Free Voltage Contacts with module IGS-PTM+IR-B8 relay board IMD TLP-M Remote control trough with InternetBridge-NT RCG-13 OUTPUT POWER SECTION - Options Available: Power lock 5x400A PWL Socket kit SKT The information is aligned with the Data file at the time of download. Printed on 14/05/2018 (ID 7550) 2018 PR INDUSTRIAL s.r.l. All rights reserved Image shown may not reflect actual package. Specifications subject to change without notice