DIESEL GENERATOR DATA SHEET

Similar documents
Powered by Cummins Model:YN-95C

UQ-Power Diesel Generator Set. Model: PE-91 GENERAL DATA. kw/kva Prime Power Continuous. kw/kva Standby power. kw/kva

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

18 KW / 18 KVA POWERED by

600 KW / 750 KVA POWERED by

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

28 KW / 28 KVA POWERED by

APD-ULJ250. Standby Power

130 KW / 165 KVA POWERED by

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

64 KW / 80 KVA POWERED by

30 KW / 40 KVA POWERED by

2000 KW / 2500 KVA POWERED by

55 KW / 70 KVA POWERED by

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

APD-NG400. NG Standby Power

204 KW / 254 KVA POWERED by

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

TPD2250H6.3 TECHNICAL DATA

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

SIVASA Doosan Series. SD250 Technical Data

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

DIESEL GENERATOR SET MTU 16V4000 DS2500

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

DIESEL GENERATOR SET MTU 12V4000 DS1750

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

DIESEL GENERATOR SET MTU 16V4000 DS2500

WPS350/S EP Series. Features:

WPS60/S EP Series. Features:

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

DIESEL GENERATOR SET MTU 20V4000 DS4000

DIESEL GENERATOR SET MTU 16V4000 DS2250

CGT Stamford UCI 274 E1

WPS150/S EP Series. Features:

WPS100/S EP Series. Features:

DIESEL GENERATOR SET MTU 18V2000 DS1400

kva kw kva kw N/A K.U.N.Z. Handels-&Produktions GmbH

DIESEL GENERATOR SET MTU 12V4000 DS2250

Rating Definitions and Conditions

DIESEL GENERATOR SET MTU 16V2000 DS1000

DIESEL GENERATOR SET MTU 20V4000 DS3600

DIESEL GENERATOR SET MTU 16V2000 DS1100

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Model NA 2 L

WPS250/S EP Series. Features:

70 KW / 90 KVA POWERED by

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 16V2000 DS KVA

DIESEL GENERATOR SET MTU 20V4000 DS2650

WPS20/S EP Series. Features:

Model MP150 W W

Voltage. kva kw kva kw

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET DS01650D5S

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Rating Definitions and Conditions

DIESEL GENERATOR SET DP01800D5S

Rating Definitions and Conditions

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 12V4000 DS2000

DIESEL GENERATOR SET DP03000D5S

kva kw kva kw 9,6 14 Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor

Technical Data 1600KW / 2000KVA 1450KW / 1813KVA. Bargh Afshan Alborz. Standby Power(50Hz) Prime Power(50Hz)

DIESEL GENERATOR SET MTU 12V1600 DS660

DIESEL GENERATOR SET MTU 20V4000 DS3100

DIESEL GENERATOR SET MTU 16V4000 DS2250

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

DIESEL GENERATOR SET MTU 20V4000 DS3300

DIESEL GENERATOR SET DS03200D5S

kva kw kva kw Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor Length mm

Rating Definitions and Conditions

Prime Ratings (KW/KVA) 400/ / / /910

DIESEL GENERATOR SET MTU 12V4000 DS1650

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Diesel Generating Set 315KW / 394KVA 280KW / 350KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

640 KW / 800 KVA POWERED by

Rating Definitions and Conditions

DIESEL GENERATOR SET. DE22E3 (B Series) Output Ratings. Technical Data

DIESEL GENERATOR SET MTU 20V4000 DS3250

PGDLS352KW 380/ / / / / / / / /

57 KW / 71 KVA POWERED by

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGDLS / / / / / / / / /

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Diesel Generating Set 300KW / 375KVA 275KW / 344KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

700 KVA / 550 KW POWERED by

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

Transcription:

YANAN DIESEL GENERATOR Powered by MTU Model:YN3500MTU *Drawing above for illustration purposes only Ⅰ. GENERAL DATA Prime Power kw/kva 2540 3175 Standby Power kw/kva 2800 3500 Frequency Hz/rpm 60 1800 Voltage V 440 254 Current A 4166 Connection / 3P 4W / Y Rated Power Factor / 0.8 Open Type(L W H) mm 7600x3000x2900 Open Type(Weight) kg 18530 Silent Type(L W H) mm 40ft Silent Type(Weight) kg 31400 Available for voltages 400/230V, 480/277V, 380/220V, 440/254V, 416/240V,220/127V, 208/120V All datas based on ISO 3046, altitude 100m (328ft), barometric pressure 100kPa (29.53inHg), air temperature 25 (77 F), relative humidity 30%. Please contact with YANAN engineer for correct generator capacity selection when the load application can't meet with the standard reference. YANAN diesel generators comply with standards :ISO8528,ISO 14000,ISO3046,GB755,BS5000,VDE0530, IEC34-1 All data is subject to change without notice, sorry for inform. Page 1,of 5

Ⅱ. STANDARD CONFIGURATION Engine Alternator Radiator Base frame Circuit Breaker MTU, including air filters, fuel filters, oil filter, starting motor and charging alternator etc. YNNAN brushless AC alternator Silent Type 50 (Open Type 40 ), fan protective shroud 550KW: base mounted fuel tank, anti-vibration pads, battery holder >550KW: channel steel base frame, anti-vibration pads, battery holder >1250A : Air circuit breaker(acb) Control System DEEP SEA 7320 Start Battery Installation Accessories Tool Documents Dry charged battery, available for 6 times starts under standard condition; connection cables. Bellow, Elbow and flange, Exhaust silencer, etc. YANAN standard Electric drawing, operation & maintenance manual, certification etc. Ⅲ. OPTIONAL CONFIGURATION Engine Accessories Heavy-duty air filter Coolant heater Lub oil heater Fuel and Water Separator Alternator And Accessories Stamford Leroy Somer Marathon Anti condensation heater PMG High voltage kv Cooling System Control System Circuit Breaker Automatic Transfer Swtich Start Battery 50 radiator Heat exchanger + water cooling tower + External water circulation pumping system Remote horizontal water tank system AMF Parallel Practical type in low temperature environment Control Screen Heater Other(Comap DEIF) 3/4 poles Fixed/handcart type Electric mechanism ATS cabinet Nickel-cadmium battery Maintenance-free battery Power charger and selector Charging current meter External Fuel Tank 500L 1000L 1500L 2000L 2500L 3000L 4000L 5000L Others All data is subject to change without notice, sorry for inform. Page 2,of 5

Ⅳ. ENGINE DATA Engine Model 20V4000G83 Engine power 3010 kw Aspiration Turbo-Charged Displacement 95.4 L Type V Bore Stroke 170 210 mm No. of Cylinders 20 Compression Ratio 16.4:1 Governor Type ADEC Rated Speed 1800 RPM Fuel System Prime Power Fuel Consumption Fuel # 636 L/h ASTM D975 No.2-D or BS2869 1998 Class A1, A2 Standby Power Fuel Consumption Injection System ADEC 717 L/h Lubrication System Lub Oil Capacity 390 L Lub Oil Consumption 2.15 L/h Lub # API CH-4 15W40 Max.Temperature 99 Coolant System Coolant Capacity 584 L Max. Top Tank Temp. 102 Std. Thermostat (Modulating) Range 38-79 Fan Drive method Shaft drive Cooling Fan Air Flow 3300 m3/min Fan Power 75 kw Air Intake System Combustion Air Flow 228/246 m3/min Exhaust System Maximum Air Intake Restriction 5 kpa Exhaust Gas Flow 546/612 m3/min Max.Back Pressure 8.5 kpa Exhaust Gas Temp 465 Exhaust Pipe Size 3 ф250 mm Starting System Start Mode DC24V Electric start Battery 4 200 Ah All data is subject to change without notice, sorry for inform. Page 3,of 5

Ⅴ. ALTERNATOR DATA Alternator Model SLG564E Rate Power 2870/3587 kw/kva PF. 0.8 Voltage 440/254 V Phase 3 Frequency 60 Hz Connection 3P 4W/ Y Bearing 1 Winding Pitch 2/3 Proteccion Class IP21 Insulation Class H Efficiency 96% Tel. Influence TIF:<50 Voltage Regulation ±0.5% Harmonic Coefficient THF:<2% AVR MX321 Voltage Adjust Scope ±5% Excitation System PMG Ⅵ. CONTROL SY STEM DATA MODEL DSE7320 Main feature Electronic J1939 (CAN) and nonelectronic MPU and alternator sensing engine support for diesel, gas and petrol engines all in one variant. The DSE7320 will also monitor the mains (utility) supply. Key Function 4-Line back-lit LCD text display Five key menu navigation Front panel editing with PIN protection Power save mode Customisable status screens Support for up to three remote Charge alternator failure alarm Manual speed ctrl (oncompatible CAN engines) CAN and Magnetic Pick-up/Alt sensing Overload protection Reverse power (kw & kv Ar)protection 9 configurable inputs LED and LCD alarm indication Display units Power monitoring (kw h, kv Ar,kV A h, kv Ar h) Flexible sender inputs Load switching (load shedding and dummy load outputs) Configurable timers and alarms Automatic load transfer 3 configurable maintenance alarms Unbalanced load protection Multiple date and time scheduler Independent Earth Fault trip Configurable event log (250) USB connectivity Integral PLC editor For more information, please visit the Easy access diagnostic page official website Tier 4 CAN engine support Compatible withelectronic (CAN) and non-electronic(magnetic pick-up/alternatorsensing) engines All data is subject to change without notice, sorry for inform. Page 4,of 5

Ⅶ. WARRANTY POLICY 1.Guarantee for one year or 1000 hours (accord to whichever reach first)from ex-factory date. Refer to YANAN Diesel Generator Warranty Manual for more details. 2.Wearing parts( filters), incorrect man-made operation, maintenance failures are excluded from the warranty policy Ⅷ. DRAWING (for illustration purposes only) All data is subject to change without notice, sorry for inform. Page 5,of 5