Diesel Generating Set 286KW/358KVA 260KW/325KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Standby Power(60Hz) Prime Power(60Hz) 513KW / 642KVA 456KW / 570KVA. Standard Features

Diesel Generating Set

Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features

Standby Power(60Hz) Prime Power(60Hz) 170KW / 212KVA 160KW / 200KVA. Standard Features

Diesel Generating Set 300KW / 375KVA 275KW / 344KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Diesel Generating Set 315KW / 394KVA 280KW / 350KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Diesel Generating Set 520KW / 650KVA NA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

FE - C KW / 650KVA 600KVA

Diesel Generating Set. Generator Ratings

Technical Data 280KW / 350KVA 256KW / 320KVA. Bargh Afshan Alborz. Standby Power(50Hz) Prime Power(50Hz) General Features:

CGT Stamford UCI 274 E1

Technical Data 1600KW / 2000KVA 1450KW / 1813KVA. Bargh Afshan Alborz. Standby Power(50Hz) Prime Power(50Hz)

Diesel Generating Set

Diesel Generating Set

Dual Frequency Diesel Genset

POWERED BY DOOSAN DIESEL GENERATOR SET

Prime Ratings (KW/KVA) 400/ / / /910

Weifang Ricardo Generator

SIVASA Doosan Series. SD250 Technical Data

DW Series Generator. Specification BV-DW145

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

UQ-Power Diesel Generator Set. Model: PE-91 GENERAL DATA. kw/kva Prime Power Continuous. kw/kva Standby power. kw/kva

Model NA 2 L

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Rating Definitions and Conditions

Rating Definitions and Conditions

Model MP150 W W

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

TPD2250H6.3 TECHNICAL DATA

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Rating Definitions and Conditions

Rating Definitions and Conditions

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

ENGINE DATA. 205L/s [434cfm] 565 C [1049 F] 750mm CE [30in. WG

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

Spark-ignited generator set

Prime 60Hz 18 kw / 18 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings Prime Ratings kw/kva 240MONO / / 18

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGKT / / / / / / / / / / / /

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

Spark-ignited generator set

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

DIESEL GENERATOR SET MTU 20V4000 DS3250

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

J80UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J200UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

D330 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PGDLS352KW 380/ / / / / / / / /

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

PGDLS / / / / / / / / /

WPS150/S EP Series. Features:

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

WPS20/S EP Series. Features:

Rental Power QSB7 series engine

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Diesel generator set QSL9-G7 series engine

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

WPS60/S EP Series. Features:

V500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

GE.PK.022/020.SS+0_all

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Voltage adjusting range % Voltage stabilization time(100% load sudden reduce) 3. Voltage fluctuation rate: Frequency volatility ±0.

PGDLS / / / / / / / / /

Diesel generator set QSK23 series engine

Rental Power QSL9 series engine

Diesel generator set 6BT5.9 series engine

Rating Definitions and Conditions

WPS100/S EP Series. Features:

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

GE.VO.360/325.SS+0_all

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Transcription:

MODEL Standby Power(50Hz) Prime Power(50Hz) 1320KW /1650KVA 1200KW /1500KVA Standard Features General Features: Engine ( Perkins 4012-46 TAG2A ) Radiator 50 O C max,fans are driven by belt, with safety guard 24V charge alternator Alternator: single bearing alternator IP23,insulation class H/H Absorber Dry type air filter, fuel filter, oil filter, coolant filter Main line circuit breaker Standard control panel batteries, rack and cable Ripple flex exhaust pipe, exhaust siphone, flange, muffler User manual PHOTO FOR REFERENCE ONLY Generator Ratings Voltage HZ Phase Standby Prime P.F Standby Ratings Ratings (COS ) Amps (KW/KVA) (KW/KVA) 440/254 50 3 0.8 2165 1320/1650 1200/1500 415/240 50 3 0.8 2296 1320/1650 1200/1500 400/230 50 3 0.8 2382 1320/1650 1200/1500 380/220 50 3 0.8 2507 1320/1650 1200/1500 Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97(eqvISO8528); A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation. Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating. Sales Promises Baifa Power provides a full line of brand new and high quality products. Each and every unit is strictly factory tested. Warranty is according to our standard conditions: 12 months or 1,000 running hours, subject to the earlier one. Service and parts are available from Baifa Power or distributors in your location. Specifications may change without notice 1/5

ENGINE DATA Manufacturer / Model: Air Intake System: Fuel Injection System: Cylinder Arrangement: Perkins 4012TAG2A,4-cycle Turbo, Air/Air cooling Direct Injection 12 in V Displacement: 45.842L Bore and Stroke: 160 190(mm) Compression Ratio: 13.6 Rated RPM: Max. Standby Power at Rated RPM: Governor Type: 1500rpm 1437KW/1955HP Electronic Exhaust System Exhaust Gas Flow(after turbo): 315m 3 /min Exhaust Temperature: 450 Max Back Pressure: 6.12kPa Air Intake System Max Intake Restriction: Consumption: Air Flow: 3.8kPa 128m 3 /min 1308m 3 /min Fuel System 100%( Prime Power) Load: 200 g/kwh 75%(Prime Power) Load: 50%(Prime Power) Load: 201 g/kwh 203 g/kwh 100%( Prime Power) Load: 295.1L/h Oil System Oil Consumption: Engine Oil Tank Capacity: Min Oil Pressure at Rated RPM: 0.52g/KWhr 159L 340kPa Cooling System Total Coolant Capacity: 212L Thermostat: 71-85 Max Water Temperature: 96 Specifications may change without notice 2/5

ALTERNATOR SPECIFICATION GENERAL DATA Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards. Alternator Data Number of Phase: 3 Connecting Type: 3 Phase and 4 Wires, Y type connecting Number of Bearing: 1 Power Factor: 0.8 Protection Grade: IP23 Altitude: 1000m Exciter Type: Brushless, self-exciting Insulation Class, Temperature Rise: H/H Telephone Influence Factor (TIF): <50 THF: <2% Alternator Capacity: 1550KVA Alternator Efficiencies: 95.7% GENERATING SET DATA Voltage Regulation: ±5% Voltage Regulation, Stead State: ±1% Sudden Voltage Warp (100% Sudden Reduce): +25% Sudden Voltage Warp (Sudden Increase): -20% Voltage Stable Time (100% Sudden Reduce): 6S Voltage Stable Time (Sudden Increase) 6S Frequency Regulation, Stead State: 5% Frequency Waving: 1% Sudden Frequency Warp (100% Sudden Reduce): +12% Sudden Frequency Warp (Sudden Increase): -10% Frequency Recovery Time (100% Sudden Reduce): 5S Frequency Recovery Time (Sudden Increase): 5S Specifications may change without notice 3/5

Standard Features COMAP Standard Auto Control System Starting batteries ( Maintenance-Free & Watering-Free) with connective wires Oil Drain Valve Permanent Magnet Generator(PMG) Exhaust System( including until muffler) Documents Options Options Daily Fuel Tank Alternator Heater Remote Control Panel Battery Charger Rainproof Type Paralleling System Engine Heater Soundproof Type Automatic Transfer Switch Water Separator Spare Parts Switch box Dimension & Weight Standard Configuration (Open Type) Overall Size: 4750(mm) 1710(mm) 2300(mm) Weight: 12500kg Soundproof Type(Standard 20 ft high container) Overall Size:6058(mm) 2438(mm) 2896(mm) Weight: 17500kg Specifications may change without notice 4/5

Auto Module Control Panel Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu. Features: MRS10-can receive remote output signal from ATS and realize auto start and stop of generators. MRS16-can realize all functions of MRS10, add RS232 interface which can communicate with PC to realize remote operation. AMF25-Auto Mains Failure controller, can realize all functions of MRS16, furthermore can detect ATS and control directly. Auto Parallel Control Panel Automatic Parallel Control Panel This new automatic parallel system adopts intelligent modules, inserted and folded installed, no need the peripheral relay and logic circuit. The main switch adopts electronic breaker or frame breaker, combined together with the generator, which is very reliable. One generator, one panel. The panel can be used both for singly and parallel. It is only need to parallel generator with such panel when the capability needs to be enlarged in the future. Specifications may change without notice 5/5