Ordering Keys Electrak DC-actuators Electrak 3 S4-09A4-06 S - = Electrak, Vdc S4 - = Electrak, 4 Vdc 09A4 - = 5 lbf 7A8 - = 75 lbf 0 = inch Electrak SP 3 SP4-09A4-06 SP - = Electrak SP, Vdc SP4 - = Electrak SP, 4 Vdc 09A4 - = 5 lbf 7A8 - = 75 lbf 0 = inch Electrak 050 3 4 5 6 DE4-7W44-06 FN HH N DE - = Electrak 050, Vdc DE4 - = Electrak 050, 4 Vdc DE36 - = Electrak 050, 36 Vdc DEQ = Electrak 050, Vdc, Q-version DE4Q = Electrak 050, 4 Vdc, Q-version DE36Q = Electrak 050, 36 Vdc, Q-version 7W4 - = lbf 7W4 - = 60 lbf 7W44 - = 30 lbf 0 = inch 4. End of stroke limit switches and potentiometer FN = limit switches and no potentiometer FP = limit switches and potentiometer 5. Rear and front mounting HH = standard crosshole in both ends MH = crossholes rotated 90 6. Color N = black housing W = white housing Not possible in combination with 8 inch stroke. Electrak 3 4 D - 0A5 -. Input voltage D - = Vdc and speed 0A5 - = 50 lbf, high speed 0A5 - = 50 lbf, standard speed 4. Shipment version D = distributor version Contact customer service for other stroke lengths. Leave position blank for OEM version. 68
Linear Actuators Ordering Keys Electrak DC-actuators Electrak PPA-DC 3 4 5 6 PPA4-58B65-8 N - LS X PPA - = Electrak PPA-DC, Vdc PPA4 - = Electrak PPA-DC, 4 Vdc PPA36 - = Electrak PPA-DC, 36 Vdc PPA90 - = Electrak PPA-DC, 90 Vdc 8B65 - = 750 lbf 58B65 - = 500 lbf 8 = 8 inch 36 = 36 inch 4. Brake option N - = no brake option 5. Feedback option XX = no feedback option LS = end of stroke limit switches HS = encoder HL = encoder + end of stroke limit switches 6. Bellows option X = no bellows C = bellows Electrak 0 3 D - 0B5-04. Input voltage D - = Vdc D4 - = 4 Vdc D36 - = 36 Vdc and speed 05B5 - = 500 lbf 0B5 - = 000 lbf, high speed 0B5 - = 000 lbf, standard speed Electrak Pro 3 4 5 6 7 PR4 0-8B65-04 R C S PR = Electrak Pro, Vdc PR4 = Electrak Pro, 4 Vdc and screw type 0-A65 = 50 lbf, acme 05-4A65 = 500 lbf, acme 07-8A65 = 750 lbf, acme 05-B65 = 500 lbf, ball 0-4B65 = 000 lbf, ball 5-8B65 = 500 lbf, ball 0-8B65 = 000 lbf, ball 3. Protection class - = IP66 (standard) E = IP67 4. Stroke (S) 5. Control PCB options S = electronic load monitoring, ELM (standard) D = ELM + encoder L = ELM + linear potentiometer P = ELM + programmable limit switches T = ELM + low level power switching R = ELM + end of stroke indication outputs U = ELM + ELM trip indication output W = ELM + PWM speed control monitoring K = ELM + signal follower input / 6. Front adapter and anti-rotation options C = freely rotatable cross hole, no anti-rotation S = cross hole in standard position, anti-rotation 3 M = cross hole rotated 90, anti-rotation 3 7. Finish S = no paint (standard) B = actuator painted black Requires anti-rotation mechanism. Only possible on Vdc input voltage models. 3 Definition of cross hole positions. (S) standard (M) 90 69
Electrak PPA-AC 3 4 5 6 PPA - 8B65-06 SB XX C PPA - = Electrak PPA-AC, 5 Vac PPA - = Electrak PPA-AC, 30 Vac 8B65 - = 500 lbf 58B65 - = 500 lbf 8 = 8 inch 36 = 36 inch 4. Brake option N - = no brake option SB = anti coast brake EB = electrical brake 5. Feedback option XX = no feedback option LS = end of stroke limit switches HS = encoder HL = encoder + end of stroke limit switches 6. Bellows option X = no bellows C = bellows See Brake in the Glossary section on page 74 for more information. Only possible for 5 Vac models. Electrak 5 3 4 A - 05B5-04 D A - = Electrak 5, 5 Vac A - = Electrak 5, 30 Vac 05B5 - = 500 lbf 0B5 - = 000 lbf 8 = 8 inch 4. Shipment version D = distributor version Leave position blank for OEM version. Electrak 05 3 4 ALP - 0B5-04 ALP - = Electrak 05, 5 Vac ALP - = Electrak 05, 30 Vac 05B5 - = 500 lbf 0B5 - = 000 lbf 8 = 8 inch 4. Shipment version D = distributor version Leave position blank for OEM version. 70
Linear Actuators Ordering Keys Lifting Columns TC6 3 4 5 TC6-4 TM 300 9 X TC6-4 = TC6, 4 Vdc TM = 450 lbf (S) = distance in mm 4. Length of the retracted unit (L) = distance in mm 5. Options X = no option E = encoder S min. = 00 mm (7.87 in) S max. = 400 mm (5.74 in) Max. possible stroke = L - 8 mm (. in) L min. = 50 mm (9.84 in) L max. = 400 mm (5.74 in) DMD 3 4 DMD4-0B5-6 PO DMD - = DMD, Vdc DMD4 - = DMD, 4 Vdc DMD36 - = DMD, 36 Vdc. Dynamic / static load capacity and screw type 05A5 - = 50 / 550 lbf, acme 05B5 - = 500 / 4050 lbf, ball 0A5 - = 500 / 550 lbf, acme 0B5 - = 000 / 4050 lbf, ball 0A5 - = 500 / 550 lbf, acme 0B5 - = 000 / 4050 lbf, ball B5 - = 500 / 4050 lbf, ball 0 = 0 inch 4 = 4 inch 6 = 6 inch 8 = 8 inch 0 = 0 inch 4. Options Leave position blank for no option. DMA 3 4 DMA - 0A5-06 DMA - = DMA, 5 Vac DMA - = DMA, 30 Vac. Dynamic / static load capacity and screw type 05A5 - = 50 / 550 lbf, acme 05B5 - = 500 / 4050 lbf, ball 0A5 - = 500 / 550 lbf, acme 0B5 - = 000 / 4050 lbf, ball 0A5 - = 500 / 550 lbf, acme 0B5 - = 000 / 4050 lbf, ball B5 - = 500 / 4050 lbf, ball 0 = 0 inch 4 = 4 inch 6 = 6 inch 8 = 8 inch 0 = 0 inch 4. Options Leave position blank for no option. 7
Ordering Keys Rodless Actuators LM80-H 3 4 5 6 7 DT4 - B6M - 40 A C H X DT - = LM80, Vdc DT4 - = LM80, 4 Vdc. Load torque capacity and screw type T68M - = 00 lbf-in, acme B6M - = 3540 lbf-in, ball B6M - = 600 lbf-in, ball B65M - = 6640 lbf-in, ball 050 = 500 mm (9.68 in) 060 = 600 mm (3.6 in) 070 = 700 mm (7.56 in) 080 = 800 mm (3.49 in) 090 = 900 mm (35.43 in) 00 = 000 mm (39.37 in) 0 = 00 mm (43.30 in) 0 = 00 mm (47.4 in) 30 = 300 mm (5.8 in) 40 = 400 mm (55. in) 50 = 500 mm (59.05 in) 60 = 600 mm (6.99 in) 4. Motor position A = 0 (standard) B = 60 C = 0 D = 80 E = 40 F = 300 5. Motor enclosure C = with enclosure (IP44) U = no enclosure (IP33) 6. Mounting position H = horizontal 7. Options X = no option H = manual override LM80-V 3 4 5 6 7 DT4 - B6M - 40 A C V X DT - = LM80, Vdc DT4 - = LM80, 4 Vdc. Load torque capacity and screw type T68M - = 00 lbf-in, acme B6M - = 3540 lbf-in, ball B6M - = 600 lbf-in, ball B65M - = 6640 lbf-in, ball 050 = 500 mm (9.68 in) 060 = 600 mm (3.6 in) 070 = 700 mm (7.56 in) 080 = 800 mm (3.49 in) 090 = 900 mm (35.43 in) 00 = 000 mm (39.37 in) 0 = 00 mm (43.30 in) 0 = 00 mm (47.4 in) 30 = 300 mm (5.8 in) 40 = 400 mm (55. in) 50 = 500 mm (59.05 in) 60 = 600 mm (6.99 in) 4. Motor position A = 0 (standard) B = 60 C = 0 D = 80 E = 40 F = 300 5. Motor enclosure C = with enclosure (IP44) U = no enclosure (IP33) 6. Mounting position and spline safety function V = vertical with motor down, no spline safety function F = vertical with motor down, with spline safety function 7. Options X = no option H = manual override 7
Linear Actuators Ordering Keys Non-driven and Rotary Actuators Electrak PPA-M 3 4 PPA00-0B65-4 N-XXX. Model PPA00 - = Electrak PPA-M 0B65 - = 500 lbf 8 = 8 inch 36 = 36 inch 4. Bellows option N-XXX = no bellows N-XXC = bellows DGB 3 D36 - GB - XXCL. Input voltage D - = Vdc D4 - = 4 Vdc D36 - = 36 Vdc. Load torque capacity and no load speed GB - = 75 lbf-in, 00 rpm 30GB - = 75 lbf-in, 40 rpm 3. Version XXCL = one output shaft + clevis mount XXMO = one output shaft + manual override XXDS = dual output shafts 73