Ex-proof ISO cartridge valves multicertification ATEX, IECEx, EAC or North American certification CULUS directional control, ISO 7368

Similar documents
Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification ATEX, IECEx, EAC or CULUS certification

ISO cartridge valves type LIDEW* and LIDBH*

ISO cartridge valves type LIDD and LIQV Flow control, ISO 7368 sizes 16 63

DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W

Solenoid directional valves type DHAL8 and DHWL8 direct operated, ISO 4401 size 06, ex-proof or intrinsically safe, low leakage execution

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Safety cartridge valves with poppet position monitoring

ISO cartridge valves type LIM*, LIRA, LIC*

Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - ATEX or IECEx certification

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

Solenoid directional valves type DPHI and DPHE two stage, ISO 4401 size 10, 16, 25 and 32

Pressure control valves type AGIR, AGIS, AGIU two stage, subplate mounting, ISO 5781 sizes 10, 20 and 32

SOLENOID DIRECTIONAL VALVE

Pressure relief valves type ARAM

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06

Solenoid directional valves Pmax 420 bar direct operated, ISO 4401 size 06 and size 10

Safety directional valves with spool position monitoring

Proportional relief valves

Solenoid directional valves type DPHI, DPHU

Proportional reducing valves

Safety valves direct, pilot operated and cartridge execution

Proportional pressure reducing cartridges type LIRCZO normally closed, ISO 7368 sizes from 16 to 40

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES

Proportional relief valves with integral pressure transducer

Proportional reducing valves

Proportional reducing valves with integral pressure transducer

Solenoid directional valves type DPHI, DPHE, DPHER two stage, ISO 4401 size 10, 16, 25 and 32

Proportional reducing valves

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

2/2 Solenoid Cartridge Valve, Size 6

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Proportional relief valves with integral pressure transducer

VSD*HL-*-KD2 - HAZARDOUS LOCATION, SOLENOID, DIRECT & PILOT OPERATED VALVES

VALIADIS S.A. HELLENIC MOTORS

Proportional flow valves

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Q max (see specifications table)

General Specifications DRV DRV-Exm DRV-Exd

Complementary safety valves with /FC mechanical microswitches conforming to Machine Directive 2006/42/CE

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

INSTRUCTION MANUAL (ATEX / IECEx)

Proportional relief valves with integral pressure transducer

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Ex m Solenoid Operator Type 0519

Ex-proof proportional valves multicertification ATEX, IECEx, EAC

The safety you rely on.

Directional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents. RE Edition: Replaces:

2-way cartridge valve, actively controllable. Type LC2A. Features. Contents. RE Edition: Replaces:

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Check valve, pilot operated. Type SV and SL. Features. Contents. RE Edition: Replaces:

INSTRUCTION MANUAL (ATEX / IECEx)

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4

Directional spool valves, direct operated, with solenoid actuation. Type WE. Contents. Features. RE Edition: Replaces:

3/2 directional spool valve, direct operated with solenoid actuation

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

SD3E-B2. Functional Description. 2/2 Way Solenoid Operated Directional Control Valves Poppet Type HA /2012. Replaces HA /2010

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

3-Way Solenoid Valve - Direct Acting

DXPE*J /117 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 31

Spring loaded resistance thermometer

Certificate of Compliance

Position Switches Series 8070/2

98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

ADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

Solenoid coils VACF Type codes

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

2/2- way directional valve type URZS40 Cover of directional valve type ULZS40

Chapter 2: Directional Control Valves

p max (see table of performances) Q max (see table of performances) MD1K MD1KD bar

Operating Instructions

2/2 directional seat valve, direct operated with solenoid actuation

Check valve, pilot operated

solenoid valves

3/2 and 4/2 directional seat valves with solenoid actuation

Lifting / Lowering valve type HSV

Operating Instructions

SOLENOID VALVES no voltage release (lever type) manual reset construction 1/4 to 1/2

Directional spool valves, direct operated, with solenoid actuation. Type WE

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

3/2 and 4/2 directional seat valves with solenoid actuation

Explosion protected hydraulic products. Product overview industrial and mobile hydraulics

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Check valve, pilot operated

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511

Proportional pressure control cartridges with integral pressure transducer

Type Z & Ex pz purge and pressurization system

Proportional pressure valves with remote pressure transducer digital, closed loop high performances, rugged design Available only on request

Position Switches Series 8060/2

Pneumatic control unit for decentralized automation of ELEMENT process valves

CCAI, CCAIF, CCAIF..H

Transcription:

Table EX5/E Replaces E/E E5/E Exproof ISO cartridge valves multicertification TEX, IECEx, EC or North merican certification CULUS directional control, ISO 7 Functional cover Poppet Sleeve Spring Ex proof pilot valve MODEL CODE OF COVERS to be coupled with cartridge in section 5 LI D EW Y X LIDEW/*O SC LI* Directional ISO cartridge valves equipped with exproof solenoid pilot valve, certified for safe operation in hazardous environments, with potentially explosive atmosphere Certifications: Multicertification TEX, IECEx and EC for gas group II G and dust category II D Multicertification TEX and IECEx for gas group I M (mining) CULUS North merican certification for gas group C&D The flameproof solenoid enclosure prevents the propagation of accidental internal sparks or fire to the external environment The solenoid is also designed to limit its surface temperature within the classified limits LIDEW: directional control with exproof solenoid valve for pilot selection LIDH: directional control with exproof solenoid valve and shuttle valve for pilot selection Size to (ISO 7) Flow to l/min at p 5 bar Max pressure: 5 bar / M O / * DC ** / * * Cover according to ISO 7 D = directional function Optional different setting of the calibrated plugs in the pilot channels see sect EW = with pilot solenoid valve H = as EW plus shuttle valve for pilot selection Cover configuration see section LIDEW:,,,, 5, LIDH:, C,, C Size (ISO 7) = = 5 = 5 = 5 = = Series number Seals material, see section : = NR PE = FKM T = HNR () Solenoid threaded connection for cable gland fitting: GK = GK/ not for CULUS M = Mx,5 not for CULUS NPT = / NPT Certification type O =Multicertifications for Group II G / II D () O/M =Multicertifications for Group I M, TEX (mining) O/UL = CULUS North merican certification Voltage code see section 9 Options: = cartridge piloted via port of solenoid pilot valve E = external attachments X (/" GS) and underneath port X supplied plugged (only for sizes ) O = horizontal cable entrance () WP = manual override protected by metallic cap () Not for multicertification M group I (mining) () The valves with Multicertification for Group II are also certified according to Indian petroleum and Explosion Safety Certification PESO The PESO certificate can be downloaded from wwwatoscom catalog on line, technical information section The pressure at T port makes difficult the manual override operation that can be possible only if its value is lower than 5 bar EX5

VLVES CONFIGURTIONS ND HYDRULIC SYMOLS LIDEW LIDEW* LIDEW* LIDEW* LIDEW5* LIDEW* LIDH LIDH* LIDHC* LIDH* LIDHC* OPTIONS For LIDEW*, LIDH* covers (sizes ): /E = with external attachments Pp and underneath port X supplied plugged; For all the models: / = cartridge piloted via port of solenoid pilot valve; /F = prearranged for coupling to an intermediate element with poppet position detector for safety function See tab EY /WP = prolonged manual override protected by rubber cap for solenoid pilot valve See table K5 *** = Calibrated plugs different from standard ones reported in section The restrictors configuration (if different from the standard) must be indicated at the end of the model code: LIDEW /* O DC ** P Channel where the orifice has to be provided: P = channel X, port P Z = channel Z F = channel F Z = channel Z Size of the throttling hole in teths of millimeters: 5 =,5 mm =, mm 7 =,7 mm =, mm =, mm =, mm =, mm 5 =,5 mm STNDRD ORIFICES CONFIGURTION Cover LIDEW* LIDEW* LIDEW* LIDEW* Port LIDH* LIDH* LIDH* LIDH* Z (only for LIDH**) M M M M 5 7 M P M M M 5 7 M M = screw size; = calibrated orifices diameter in tenths of mm; = short calibrated hole LIDEW*5 LIDH*5 M M LIDEW* LIDH* M M

5 MODEL CODE OF SLIPIN CRTRIDGES, to be coupled with covers in section SC LI /* Cartridge valve Size (ISO 7): 5 5 High flow: = all sizes Seals material: = NR PE = FKM T = HNR Type of poppet, see section for maximum flow, = as but with dumping nose = as but with dumping nose Spring cracking pressure: =, bar for poppet, ; =, bar for poppet, ; =,5 bar for poppet, ; = bar for all poppets = 5,5 bar for all poppets TYPE OF POPPET Type of poppet Functional sketch (Hydraulic symbol) Operating pressure Size Nominal flow 5 at p 5bar (l/min) see diagrams Q/ p 5 at section 9 P P P bar max (only SCLI cartridge) 7 7 55 55 5 5 7 7 5 5 P Typical section rea ratio :p Cracking pressure Cracking pressure Spring Spring :, :,5 :, :,5, bar, bar, bar, bar,5 bar,5 bar bar,5 bar bar,5 bar bar bar bar bar,9 bar bar,9 bar, bar, bar bar, bar 9 bar 59, bar 9 bar bar, bar bar 59, bar 7 GENERL CHRCTERISTICS ssembly position / location ny position Subplate surface finishing Roughness index Ra, flatness ratio,/ (ISO ) MTTFd values according to EN ISO 9 75 years, for further details see technical table P7 mbient temperature Standard = C +7 C /PE option = C +7 C /T option = C +7 C Storage temperature range Standard = C + C /PE option = C + C /T option = C +7 C Surface protection Zinc coating with black passivation (cover and solenoid pilot valve) Compliance Explosion proof protection, see section HYDRULIC CHRCTERISTICS Functional cover operating pressure port,, X, Z, Z = 5; port Y = Rated flow see section EX5

9 ELECTRICL CHRCTERISTICS Valve type VDC ±% Voltage code () VC 5/ Hz ±% Power consumption at C Coil insulation Protection degree with relevant cable gland Duty factor LIDEW*/O LIDH*/O LIDEW*/O/M LIDH*/O/M DC, DC, DC, DC, DC, 5DC, DC C, C, C, C W class H IP/7 to DIN EN59 % LIDEW*/O/UL LIDH*/O/UL DC, DC, DC, 5DC, DC C, C, C, C W raintight enclosure, UL approved () For alternating current supply a rectifier bridge is provided builtin the solenoid For power supply frequency Hz, the nominal supply voltage of solenoids C and C must be 5/ and / respectively SELS ND HYDRULIC FLUIDS for other fluids not included in below table, consult our technical office Seals, recommended fluid temperature NR seals (standard) = C + C, with HFC hydraulic fluids = C +5 C FKM seals (/PE option) = C + C HNR seals (/T option) = C + C, with HFC hydraulic fluids = C +5 C Recommended viscosity 5 mm /s max allowed range 5 mm /s Fluid contamination class ISO class /9/ NS class, in line filters of 5 µm (β5 _>75 recommended) Hydraulic fluid Suitable seals type Classification Ref Standard Mineral oils NR, FKM, HNR HL, HLP, HLPD, HVLP, HVLPD DIN 55 Flame resistant without water FKM HFDU, HFDR Flame resistant with water NR, HNR HFC ISO 9 The ignition temperature of the hydraulic fluid must be 5 C higher than the max solenoid surface temperature () Performance limitations in case of flame resistant fluids with water: max operating pressure = bar max fluid temperature = 5 C EXPROOF SOLENOIDS CERTIFICTION DT Valve type LIDEW*/O LIDH*/O LIDEW*/O/M LIDH*/O/M LIDEW*/O/UL LIDH*/O/UL Certifications TEX IECEx EC TEX IECEx CULUS Multicertification Group II Multicertification Group I North merican CULUS Solenoid certified code Type examination certificate () O O/M O/EC TEX: CESI TEX IECEx: IECEx CES x EC: TC RU CIT 7 TEX: CESI TEX 57x IECEx: IECEx CES 7x 7 E Method of protection Temperature class Surface temperature mbient temperature () Mechanical construction Flameproof enclosure Ex d Cable entrance: threaded connection vertical (standard) or horizontal (option /O) TEX //EU Ex II G Ex d IIC T/T/T Gb Ex II D Ex tb IIIC T5 C/T C Db IECEx Ex d IIC T/T/T Gb Ex tb IIIC T5 C/T C Db EC Ex II G Exd IIC T/T T 5 C +5 C T 5 C +7 C 5 C +7 C EN 79:, EN 79: 7 GK = GK/ M = Mx,5 NPT = / NPT TEX //EU Ex I M Ex db I Mb IECEx Ex db I Mb UL Class I, DivI, Groups C & D Class I, Zone I, Groups II & II T T5 5 C C +55 C +7 C UL and UL9, CS n 9 CS n 9 / NPT NSI/SME () The type examinator certificates can be downloaded from wwwatoscom catalog on line, technical information section () The solenoids Group II and CULUS are certified for minimum ambient temperature C In case the complete valve must withstand with minimum ambient temperature of C, select /T in the model code WRNING: service work performed on the valve by the end users or not qualified personnel invalidates the certification

EX PROOF SOLENOIDS WIRING n M locking torque Nm Multicertification n M locking torque Nm CULUS certification Standard version Option /O Standard version Option /O cover with threaded connection for vertical cable gland fitting cover with threaded connection for horizontal cable gland fitting terminal board for cables wiring standard manual override screw terminal for additional equipotential grounding = Coil = GND = Coil PC poles terminal board suitable for wires cross sections up to,5 mm (max WG) cover with threaded connection for vertical cable gland fitting cover with threaded connection for horizontal cable gland fitting terminal board for cables wiring standard manual override = Coil + = GND = Coil Pay attention to coil polarity PC poles terminal board suggested cable section up to,5 mm (max WG), see section note alternative GND screw terminal connected to solenoid housing CLE SPECIFICTION ND TEMPERTURE Power supply and grounding cables have to comply with following characteristics: Multicertification Group I and Group II Power supply: section of coil connection wires =,5 mm Grounding: section of internal ground wire =,5 mm section of external ground wire = mm culus certification: Suitable for use in Class I Division, Gas Groups C rmored Marine Shipboard Cable which meets UL 9 Tinned Stranded Copper Conductors ronze braided armor Overall impervious sheath over the armor ny Listed (UVZ/ UVZ7) Marine Shipboard Cable rated V min, 5 min C,5 mm ( WG) having a suitable service temperature range of at least 5 C to + C ( /T Models require a temperature range from C to + C) Note : For Class I wiring the C,5 mm WG cable size is admitted only if a fuse lower than is connected to the load side of the solenoid wiring Cable temperature The cable must be suitable for the working temperature as specified in the safety instructions delivered with the first supply of the products Multicertification Max ambient temperature [ C] Temperature class Group I Group II Max surface temperature [ C] Group I Group II 5 C 5 C 5 C 5 C Min cable temperature 5 C T not prescribed 7 C T 9 C culus certification Max ambient temperature [ C] Temperature class Max surface temperature [ C] Min cable temperature 55 C T 5 C C 7 C T5 C C CLE GLNDS only for Multicertification Cable glands with threaded connections GK/, / NPT or Mx,5 for standard or armoured cables have to be ordered separately, see tech table K Note: a Loctite sealant type 55, should be used on the cable gland entry threads EX5

5 Q/ p DIGRMS based on mineral oil ISO VG at 5 C SC LI High flow series = poppet type and = poppet type and size size 5 size size size 5 size

COVER DIMENSIONS [mm] Multicertified and UL for cartridge cavity dimensions see tech table P Size Drawing of size 5 dotted line: example of double solenoid version Option /WP 7 95 for UL Shuttle valve Only for LIDH 7 5 Option /O 55 Notes referred to the below table: () LIDEW* LIDH*: solenoid at side of port Y of cover LIDEW* LIDH*C: solenoid at side of port X of cover Size () C D max E max F G I J K Ports PpDr Ports ZZ Seals Fastening bolts () Tightening torque [Nm] Mass [Kg] 7 5 9 OR Nr Mx5 5,95 5,7 5 5 5,5 7 7 5 OR Nr Mx5 5,5, 5 7 7 5 5 OR Nr Mx55,5,7 5 5,5 5 5 5 G / OR Nr Mx7 7,75 9, 5 7 5 5 7 G / G / OR Nr Mx,5,7 9 G / G / OR5 Nr Mx9,5, 7 RELTED DOCUMENTTION X TT9 TT5 General guideline for exproof components Safety instruction for Multicertification tex, IECEx, EC Group II Safety instruction for Multicertification tex, IECEx Group I Mining 7/