Operators Manual DL3100. Dualine Automatic Spray Systems Installation, Operation, Parts List. DL3100 r#3

Similar documents
Operators Manual SL3100. Singline Automatic Spray Systems Installation, Operation, Parts List

Farval. Dualine Installation System Start-Up. Bulletin DL300 BIJUR DELIMON INTERNATIONAL

farval DUaLINE SYSTEMS Ideally suited for heavy industry Continuous duty operation Over 80 years of excellence

FARVAL DUALINE SYSTEMS + + Ideally suited for heavy industry + + Continuous duty operation + + Over 80 years of excellence

MultiPort II Lubricator

FARVAL DUALINE SYSTEMS. + Ideally suited for heavy industry + Continuous duty operation + More than half a century of excellence

MultiPort II Lubricator

Airmatic Lubricator. Pneumatic Operation, Oil. General. Application. Operation. Technical Data

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

Operators Manual TTN LUBRICATOR Series Progressive r#9

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

400 psi (28 bar) PDI & INJ. 100 psi (7 bar) PDI & INJ

EQUALIZER International Limited 10T(I) Integral Hydraulic Spreading Wedge Repair Instruction Manual

Instructions for Installation, Operation, Care and Maintenance

DM Valve LINE 1 LINE 1 LINE 2. Positive indication at every bearing. adding or subtracting points at every bearing. Has only two moving parts.

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R6 08/17

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL C ELECTRIC HYDRAULIC PUMP

Low Profile J Series Power Unit with Vane Pump

Operators Manual Electric Barrel Pump r#0

SureFire II Lubricator

Purging Air From Divider Block Lubrication Systems

STERILMATIC DIGITAL ELECTRIC STERILIZER PARTS AND SERVICE MANUAL

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#3

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R8 08/18

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800)

Vickers. Overhaul Manual. Vane Pumps. Small and Large Series Combination Pumps VC(K)(S)-**-(*)*D*-6(1) VC(K)(S)-**-(*)-*-*D*-5(1)

PARTS LIST FOR AIR COMPRESSOR/GENERATOR/WELDER AGW-SH22-20M

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - Q3. MAY FORM Section

REPAIR PROCEDURES MANUAL

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

SERVICE INSTRUCTIONS. Transfer Pump

PARTS LIST FOR AIR COMPRESSOR/GENERATOR/WELDER AGW-SR14-30M AGW-SR14-B

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R3 09/09

3000 psi (207 bar) Output/ min. 115 VAC 10cc (0.61 cu. in.) 24 VDC 12cc (0.73 cu. in.) Discharge Element Output Port.

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

Oil Streak Air-Oil Generating Unit

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - 13C MAY FORM Page. Section - Q3

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800)

INSTALLATION, OPERATING AND SERVICE MANUAL

ATTENTION! READ BEFORE ATTACHING THE AIR HOSE

Form No Parts List for: RWP55 RWP55-4 MODEL C HYDRAULIC PUMP AIR DRIVEN WITH REMOTE CONTROL GENERAL ASS'Y SIDE VIEW SECTION A-A

Model CHASSIS LUBE ELECTRIC GREASE PUMP Series "C"

Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation:

TYPE E Main Valve Sizes 3 /8 through 12

Athletic Field Painting Pointers Line Star Drawing Line Star Parts List 3-4. Spray Boom Drawing Stainless Steel Tank 6

Model AD-29A Automatic Air Spray Gun and Can Marking System

OK-01 TRAM WHEEL FLANGE LUBRICATION APPLICATION DESCRIPTION

Use Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature. See Bijur Engineering Manual for system limitations.

Lubemaster Pump DESCRIPTION

PRESSURE REDUCING CONTROL VALVE

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

CAUTION: The possible problems and causes are listed in order of likelihood and ease of checking.

Owner s and Maintenance Manual for: Lincoln QuickLub Systems

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

CXL2 Injectors & Manifolds

ELECTRIC HYDRAULIC PUMP

Centro-Matic. Automated Lubrication Systems

PARTS LIST FOR AIR COMPRESSORS AC-SH20-2 AC-SV20-2 ENGINE OIL GRADE: HONDA: SAE 10W-30. Below 40 F=SAE 10W-30 ENGINE OIL CAPACITY:

Form No CE Parts List for:

Property of American Airlines

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

CENTRO-MATIC PUMP, MODELS 84050, & 85460

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

MODEL 10LH SPECIFICATION

MAINTENANCE MANUAL. Covering Models: Series (1/4-10 ) S Series (1/4-1 ) Series (3-10 )

SureFire II Lubricator

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

Service Handbook HD /97

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

MACH 1A HVLP (MACH 1AV HVLP) Automatic Airspray Gun

Series 3000 Divider Valve Manifold

Table of Contents WARRANTY

Troubleshooting the Transmission Hydraulic System

Your key to maximum design flexibility with seriesprogressive

PARTS LIST FOR WLP-40-0M10 WATER RECYCLING TREATMENT SYSTEM

OPERATION AND PARTS MANUAL

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800)

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

CAUTION: The possible problems and causes are listed in order of likelihood and ease of checking.

SERIES G3DB/AG3DB ELEVATOR

IMT Bead Breaker 1000

Instructions for Installation, Operation Care and Maintenance

OPERATION AND PARTS MANUAL

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

AIR-OIL injector BLOCK. Oil Streak Generating, Mixing and PDI systems

JACKALL HYDRAULIC SYSTEM

Signet 2517 Brass Paddlewheel Flow Sensor * *

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

CW-2004-SME3: PARTS LIST FOR (AFTER SERIAL # ) Motor Horsepower: Pump Oil Capacity: Nozzle Size: CW-2004-SME3: 5.5

MODEL B ELECTRIC HYDRAULIC PUMP

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

Installation & Operator s Manual

Transcription:

Operators Manual DL3100 Dualine Automatic Spray Systems Installation, Operation, Parts List DL3100 r#3

TABLE OF CONTENTS Introduction.................................................................... 2 Typical system (Pump close to valve panel)......................................... 3 System - Sequence............................................................... 3 Typical System (Pump remote from valve panel).................................... 4 Central Pumping Stations........................................................ 5 Valve Panels.................................................................... 6 Lance Design................................................................... 7 SC400 Controller................................................................ 8 Air Requirements............................................................... 9 SC1-2 Spray Control Valves - Dimensions & Parts.................................. 10 SC1-2 Spray Control Valves - Operation & Adjustment.............................. 11 SC1-2 Spray Control Valves - Conversion For After Blow............................ 12 Installation Instructions......................................................... 13 Location For Valve Panels And Spray Lance........................................ 14 Startup And Maintenance Procedures............................................. 15 System Diagnosis............................................................... 16 INTRODUCTION The spray systems described in this bulletin are used to lubricate large gear and pinion sets such as found on ball mills, rod mills, kilns, etc. Each systems includes an air operated pumping station, a measuring valve panel, a spray nozzle, electrical controls and a number of optional features. Gear face widths of 2" to 42" can be lubricated with nozzles and nozzle spacing designed accordingly. Since Bijur Delimon gear spray systems operate intermittently they can be thought of as film maintaining devices. The electrical controls provide broad cycling flexibility as well as fault monitoring and after blow to purge the nozzles. Illustrations and specifications are not binding in detail. Designs are subject to modification and improvement without notice. 2

TYPICAL SYSTEM (Pump Close To Valve Panel) Figure - 1 SEQUENCE OF OPERATION (System Shown in Fig.1) 1. SC400 times out, opening the two solenoid air valves. The pump starts. A measured volume of lubricant discharges from each of the measuring valves to its spray nozzle. Air flows thru the air manifold to the spray nozzles, atomizing the lubricant to a penetrating spray. 2. When each measuring valve has discharged once to its spray nozzle, system pressure begins to increase until at a predetermined point, it shifts the reversing valve; (Factory set @ 1500 psi) Reversing valve limit switch is operated closing the pump solenoid air valve, but a time delay device in the SC400 keeps the nozzle solenoid air valve open for a preset time period after lube flow stops. The air thoroughly cleanses the nozzles. Lube pressure in the system is relieved to reservoir by the reversing valve and alternate supply line is readied for pressurizing during next pumping cycle when the foregoing sequence is repeated. NOTE: For component part numbers, refer to fig's. 2 and 3. 3

SCHEMATIC - TYPICAL SYSTEM (Pump Remote From Valve Panel) Figure - 2 SYSTEM DETAILS AND PART NUMBERS ITEM # PART NUMBER QTY. DESCRIPTION 1 9120 1 120lb Air Operated Barrel Pump 2 DR460A 1 Reversing Valve 3 LD7767CA1 1 Air Control Panel *4 U623 1 Air Pressure switch 5 200275 1 Lube Supply Hose Kit (72") 6 200324 1 Relief Hose Kit (72") 7 200325 1 Air hose Kit (72") 8 U1929D (OIL ONLY) 2 2-Way Line Checks 9 BY USER 1 Supply Line Pipe or Hose to Panel *10 F1194G 1 Air Regulator 11 LD12361V6 1 Valve Panel 12 LD9327-XXXXX 1 Spray Lance 13 SC400 1 Timer Control * Note: Items 4 & 10 sold separately Refer to Fig. 3 for pumping station details and part numbers. (Page 5) The spray system layout shown in (Fig.2) provides guidelines for installations where the pump, reversing valve and controls cannot be located close to the valve panel. To assure good pressure distribution under various operating temperature conditions, two pipe supply lines are run from the reversing calve to within 30" of the valve panel. Two 36" hose assemblies are used to connect to the valve panel. The size of the piping for the supply lines can be selected from the table in page 13(Fig. 15). 4

CENTRAL PUMPING STATION Figure - 3 ITEM PART NO. DESCRIPTION 1 9120 120 LB Air Operated Barrel Pump 2 DR460A Reversing Valve 3 LD7767CA1 Air Control Panel 4 U623 Air Pressure Switch 5 200275 Lube Supply Hose Kit (72") 6 200324 Relief Hose Kit (72") 7 200325 Air Hose Kit (72") 8 U1929D (OIL ONLY) 2-Way Line Checks NOTE: A. The 9120 pump for 120 pound drums is recommended where solvent cut-back lubricants are used. This is to necessitate frequent drum changes to prevent drying and hardening of the lubricant. The 9400 pump for 400 pound drums is available if drying and hardening of the lubricant is not a problem. B. A U623 pressure switch (Item 4) is used to give warning of low pressure and is an optional feature. C. All Central Pumping Stations are for 120 Volts, 60 Cycle, but other voltages and frequencies are available. Electrical timing devices are described on page 8. D. The U1929D two way checks are needed only if the lubricants have fluid characteristics. 5

VALVE PANELS 3/8" NPSF LUBE INLET 24 6 1.81 5 3.94 TABLE 1. 18 23 19 1/2" NPT AIR SUPPLY 7 34.0.62 32.75 17.88 16 START 10 20 21 14 12 15 6.00 11 24 6 22 9 24 17 6 4 24 13 1/2" NPT CONDUIT CONNECTION 3 2 3.94 1.81 3.94 1.81 1.81 7.63 AVAILABLE PANELS PANEL NUMBER NUMBER SPRAY NOZZLES LD12361V1 1 LD12361V2 2 LD12361V3 LD12361V4 LD12361V5 LD12361V6 LD12361V7 3 4 5 6 7 LD12361V8 8 3/4" DIAMETER THRU 8 HOLES 12.88 15.0 1.5 2.5 APPROX. FIGURE - 4 3.94.25 VALVE PANEL LD12361V8 PARTS LIST ITEM # QTY. PART NO. DESCRIPTION 1 4 201222 Hose Assembly with Adapter - 30" long 2 1 201502 Kit - Air Supply Hose - 36" long 3 1 201595 Valve Solenoid 2-way NC 3/4"NPT 50/60Hz 4 8 U1732F Cover Indicator Stem 5 4 DM62100A Dualine Valve 6 4 201223 Hose Assembly with Adapter - 36" long 7 1 F6024MD Filter Air Line 1/2"NPT Auto Drain 8 1 LD9340V8P Plate - Mounting 9 12 U81D3 Sleeve and Nut 3/8" tube x 3/8"NPT 10 1 U101D2 Nipple 1/2"NPT x 1-1/8" long 11 1 U101E1 Nipple 3/4"NPT x 1-3/8" long 12 1 U101E19 Nipple 3/4"NPT x 7" long 13 1 U11354 Elbow Reducing Pipe 3/4" x 1/2" 14 1 U11654 Reducing Coupling 15 4 U119CC Plug 3/8"NPT 16 4 U204C15 Screw Hex Head Cap 3/8"-16 x 5/8" long 17 8 U206K6 Screw Fillet Head Machine 5/16"-18 x 2-1/2" long 18 4 U207G3 Screw Round Head Machine #10-24 x 1/2" long 19 4 U213C Washer Lock #10 20 4 U213G Washer Lock 3/8" 21 2 U2685 Bracket Mounting 3/4"NPT 22.75' U424E6 Tubing Steel 3/8" O.D. 23 1 LE9629B Pushbutton 'start' 24 8 U1104B Ell Street 1/4"NPT Shown in Fig. 4 is a typical measuring valve panel(panel assembly#ld12361v8). This panel has measuring valves to serve 8 nozzles. Panels having from 1 to 8 measuring valves are available as shown in Table 1. All panels have outside dimensions of 34" X 15". The only variable on each panel is the number of measuring valves(one to eight). DM60 size measuring valves are standard on the panels, however, smaller capacity measuring valves can be supplied if required. 6

SPRAY LANCE - MODEL LD-9327 Model LD-9327 spray lances described below include spray nozzles in which air under pressure atomizes lubricant from the valve panels and sprays it onto the gear face. Note that guard width must be exactly 3" wider than gear face width. Contact factory for special applications. B6519 "A" "B" "B" "B" "B" "B" "B" "C" A A U1078 1-1/2" PIPE CAP U922C U1104B U101B1 1-1/2" STEEL PIPE 1.5" FORGED STEEL SLIP ON FLANGE (NOT FURNISHED BY BDI) U424C6 GEAR GUARD 3/8"OD TUBING B6514 GEAR GUARD U1103B 1/2 NPT AIR INLET 1/4 NPT LUBE INLET LUBE HOSE - REF. ASSEMBLY PART # Group 1 - Assembly Numbers and Dimensions GEAR NO. OF DIMENSIONS GUARD B FACE SPRAY WIDTH A +/- WIDTH NOZZLES C +/- 1/16" 1/16" LD93271020S 2" 4.5" 1 8" - 2.25 LD93271030S 3" 5.5" 1 10" - 2.75 LD93271040S 4" 6.5" 1 11" - 3.25 LD93271050S 5" 7.5" 1 12" - 3.75 LD93271060S 6" 8.5" 1 13" - 4.50 LD93272070S 7" 9.5" 2 14" 4.00 2.25 LD93272080S 8" 10.5" 2 15" 4.50 3.00 LD93272090S 9" 11.5" 2 16" 4.50 3.50 LD93272100S 10" 12.5" 2 17" 5.00 3.75 LD93272110S 11" 13.5" 2 18" 5.25 4.13 LD93273120S 12" 14.5" 3 19" 4.38 2.87 LD93273130S 13" 15.5" 3 20" 4.38 3.37 LD93273140S 14" 16.5" 3 21" 4.68 3.57 LD93273150S 15" 17.5" 3 22" 5.00 3.75 LD93273160S 16" 18.5" 3 23" 5.25 4.00 LD93274170S 17" 19.5" 4 24" 4.50 3.00 LD93274180S 18" 20.5" 4 25" 4.50 3.50 LD93274190S 19" 21.5" 4 26" 4.75 3.75 LD93274200S 20" 22.5" 4 27" 5.00 4.00 LD93274210S 21" 23.5" 4 28" 5.25 3.88 LD93275220S 22" 24.5" 5 29" 4.50 3.25 LD93275230S 23" 25.5" 5 30" 4.75 3.50 LD93275240S 24" 26.6" 5 31" 5.00 3.75 LD93275250S 25" 27.5" 5 32" 5.25 4.00 LD93276260S 26" 28.5" 6 33" 4.38 3.30 LD93276270S 27" 29.5" 6 34" 4.38 3.80 LD93276280S 28" 30.5" 6 35" 4.68 3.55 LD93276290S 29" 31.5" 6 36" 4.68 4.05 LD93276300S 30" 32.5" 6 37" 5.00 3.75 LD93276310S 31" 33.5" 6 38" 5.25 3.63 LD93277320S 32" 34.5" 7 39" 4.38 4.11 LD93277330S 33" 35.5" 7 40" 4.68 3.71 LD93277340S 34" 36.5" 7 41" 5.00 3.25 LD93277350S 35" 37.5" 7 42" 5.00 3.75 LD93277360S 36" 38.5" 7 43" 5.25 3.50 LD93277370S 37" 39.5" 7 44" 5.25 4.00 LD93278380S 38" 40.5" 8 45" 4.68 3.87 LD93278390S 39" 41.5" 8 46" 4.80 3.95 LD93278400S 40" 42.5" 8 47" 5.00 3.75 LD93278410S 41" 43.5" 8 48" 5.10 3.90 LD93278420S 42" 44.5" 8 49" 5.25 3.88 8.0" 6.7" 5.75" 1.75" 1.67" 3.0" 9.0" 7.75" 1.22" 1.0" 4.75" VIEW A-A 60 6.75" 4.25".625" Ø.75"(X4) NOTE: "S" series spray lances are shipped with round spray nozzles installed. Flat spray nozzle set is also included with each spray lance. 7

SC400 MULTI-FUNCTION CONTROLLER/MONITOR General The SC400 Controller is a full featured lubrication control, offering two plus one functionality. The controller has the ability to operate a single pump and two zone valves (e.g. frequent/infrequent lubrication cycles) or two separate pumps (e.g. one oil pump & one grease pump). For single zone systems, the SC400 Controller also offers two intervals (e.g. weekday /weekend). The controller can activate a fill pump as needed to maintain proper fluid levels in the oil or grease reservoir. Features + 2 zone operation (for Progressive, Injector and Dualine Hydraulic systems). + IP56 enclosure, constructed of molded polyester fiberglass. + CE approved. + Four supported languages (English, French, Spanish, German). + Pump output may be powered externally or via control power. + Valve A, Valve B and Fill pump may be powered exrternally or via controller. + Critical Inputs accept PNP, NPN or mechanical switches. + 500 ma of 24 VDC is available to power customer's accessories. + Primary alarm inputs may be programmed for N.O. or N.C. functionality. + Machine watchdog and cycle monitoring. + Pause (standby), jog (manual operation). + Accepts all BDI electric reversing valves and cycle/pressure/"end-of-line" switches. Refer to the following documents for more info: Technical Data Input Voltage 85 to 265 VAC, 50/60 Hz Output Rating (Line A & B) 8 amp (90 to 250 VAC) Enclosure Rating IP-56 Idle Time Range 1 second to 100 days Machine Cycle Counts 1 to 999,999 Counts (30 counts/second at 50% duty cycle) Watchdog Timer 1 second to 60 minutes Monitor Time 1 second to 24 hours Cycle Counts On 1 to 999 counts Over Counts 0 to 9 Net Weight 5 lb Length x Width x Height 12.3 x 9.2 x 5 Fault Relay Contacts 5 amp + Datasheet #35980: SC400 Controller 8

SYSTEM AIR REQUIREMENTS A free air volume of V a cubic feet, calculated by the equation below, should be provided for each lube cycle. This is twice the theoretical air volume needed to operate both pump and nozzle. A lube cycle is defined on page 3. V a = 2V 1 (T 1 +T 2 )+2V 2 (T 1 +T 2 +T 3 ) Where: V 1 = Free air volume used by the pump*. assume = 5.0 cfm. V 2 = Free air volume used by the nozzles in cu.ft. per minute see Fig. 9. T 1 = Time in minutes to compress lube in distribution lines. see Fig. 10. NO. OF T2 NOZZLES FOR DD5X FOR DM6X V2 (cfm) 1.005.015 13.5 2.010.030 27.0 3.015.045 40.5 4.020.060 54.0 5.025.075 67.5 6.030.090 81.0 7.035.105 94.5 8.040.120 108.0 Fig. 9 - Values for T 2 and V 2..80.70 T 2 = Time in minutes required by a pump to discharge lube from the nozzles during one count. See Fig. 9. T 3 = Time in minutes for air to clean lube from nozzles after discharge. Allow 0.50 minutes. Example: Find the free air volume needed by the spray system shown in Fig.2. (Page 4) The lance has six U922C nozzles. The valve panel has six valves - DM62 valve blocks. Distribution lines consist of 100' of 1" pipe. The system is to be operated four times an hour. V a = 2 x 5 (.18 + 0.09) + 2 x 81 (.18 + 0.09 +.5) = 127cu.ft. per lube cycle Volume of free air required for one hour is: 4 x 127 = 508 cu.ft. LUBE COMPRESSION TIME T2 IN MINUTES.60.50.40.30.20.10 1-1/2 PIPE 1-1/4 PIPE 1 PIPE 3/4 PIPE 1/2 PIPE 0 0 50 100 150 200 LENGTH OF DISTRIBUTION LINES IN FEET Fig. 10 - Lube compession time T1 (based on 1% compressibility of lubricant). *The pump is assumed to be operating with air pressure regulator set between 80 and 100 psi and a line back pressure of 1000 psi (the line back pressure is usually much lower). Lube volume discharged by the pump is assumed to be 40 cubic inches per minute. 9

BDI SPRAY CONTROL VALVE & NOZZLE ASSEMBLIES APPLICATION: SC1-2 spray control valves are used on manually operated spray systems, automatic gear spray systems on shovels and drag lines, and on older gear spray panels. COMPONENT ASSEMBLIES 1. SC1 Series spray control valve 1-3/32 21/64 (X2) (identical for all assemblies) 1-3/8 1 1/2 1-3/4 2-3/4 3-27/32 2. U943 spray nozzle setup (model selected depends on lubricant and application) 1-3/8 1/2 1 2 3/8 1 1 2 1/2 11/16 TO CENTERLINE OF 1/4 NPTF LUBE UNIT NOTE: SC1-2 spray control valve and U943 spray nozzles are sold separately. Must purchase individually. HOW TO ORDER EXAMPLES: A. Spray nozzle setup if known: One SC1-2 spray control valve with spray nozzle setup. (Specify correct spray nozzle setup, whether U943A, C or F.) B. SC1-2 w/after Blow: Order P.N. SPR13241B (Order U943 separately) C. Spray nozzle setup: 1. U943A - for light oil. 2. U943C - for oil or grease - recommended for most spray applications. 3. U943F - used when flat spray pattern is desired such as spraying wire rope. SC1-2 SPRAY CONTROL VALVE WITH U943 SPRAY NOZZLE SET-UP ITEM # PART NO. DESCRIPTION *1 N/A Valve Body *2 N/A Piston 3 SC110061 Spring-Piston Stop 4 SC110072 Air Check Valve Assy. **5 Check Valve Body **6 N/A Lock Nut **7 Spring **8 Quad Ring 9 U204B6 5/16-18 x 1-3/4 Cap Scr. 10 U213F 5/16 Lockwasher 11 U219B 5/16-18 Hex Nut 12 U230D 5/16" Check Ball 19 13 U943 Spray Nozzle Set Up 20 14 U1204D 7/16-20 Dr. Ret. Scr. 13 15 U1305G 7/16" Copper Washer 18 16 U1522D Closure Plug 21 17 U1526 Ball Retainer *Items 1 & 2 shown for reference only - not for resale. **Items must be purchased in item#4. U-943 SPRAY NOZZLE SET-UP ITEM PART NO. U943A U943C U943F NAME 18 UX943A1 UX943C1 UX943C1 Fluid Nozzle 19 UX943A2 UX943C2 UX943F2 Air Nozzle 20 UX943A3 UX943A3 UX943A3 Hex Retainer 21 UX943A4 UX943A4 UX943A4 Gasket 5 14 7 6 4 17 12 8 3 2 1 15 16 10

BDI SPRAY CONTROL VALVE & NOZZLE ASSEMBLY HOW TO ADJUST MODEL SC1 SPRAY CONTROL VALVES SC1 valves are factory adjusted to function properly with NLGI #0 consistency lubricant. If other lubricants are used, the following adjustment may be needed to improve atomization or to eliminate nozzle burping at the start and end of the lube cycle. 1. Pump to 1000 psi on the pressure gauge. Relieve system with the pump solenoid valve and then loosen locknut (item 6, page 10) at the air inlet and turn check valve body (5) clockwise until air slows thru spray nozzle (13). Finally turn check valve body counterclockwise until no air escapes. 2. Repeat "1" several times if needed for good atomization. Then tighten locknut. Caution: To prevent a change in setting, hold check body firmly while tightening locknut. HOW SPRAY CONTROL VALVE & NOZZLE ASSEMBLIES OPERATE 1. Lube under pressure flows thru port A into chamber B causing piston D to move toward ball E. this both unseats the ball and opens a port from chamber B to passage G. 2. Air flows past ball E thru passage F and lube flows thru passage G. They meet in air nozzle H and produce a spray. Removal of the air nozzle will only produce a more concentrated spray. F C E 1/8 DIA. STEM THIS END D B H A G ASSEMBLY NOTES When assembling an SC1 valve, install large (1/8" dia.) end of piston D toward ball as shown in figure. SCI PERFORMANCE DIAGNOSIS - (Valve fails to operate properly) Cause Repair 1. Insufficient air supply. 1. Check pressure - should be 80psi minimum (not less than 60 psi during spray cycle) 2. Incorrect setting of air control valve. 2. Re-adjust - see above for details. 3. Clogged spray nozzle. 3. Wash with solvent and reassemble. 4. Clogged spray control. 4. Remove pilot piston and clean it and the piston bore with solvent. Reassemble. 11

SCI CONVERSION - TO PROVIDE AFTER BLOW (FOR EXISTING SPRAY PANELS EQUIPPED WITH SC1 VALVES) STAINLESS STEEL BODY LUBRICANT SOCKET SET SCREW 5/16-18 X 5/16 LG. (LOCTITE THREADS).257 DRILL 5/16-18 TAP AIR LUBE CROSSPORT TO NOZZLE FLUID NOZZLE HEX RETAINER AIR NOZZLE (MUST ORDER SEPARATELY) AIR RELEASE VALVE BODY AIR ENTRY PORT TO NOZZLE JAMB NUT FIGURE - 14 NOTES Existing spray panels equipped with SC1-2 spray control valves can be upgraded to incorporate after blow by employing the following procedure: 1. Remove items (shown on page 10) numbers 2, 3, 8, 12, 17, 7 and 14. 2. Drill piston bore.257" then tap 5/16"-18. 3. Insert 5/16"-18 x 5/16" long set screw coated with Loctite thread locker. 4. Insert solenoid air shut-off valve in air line to nozzles and wire in parallel with air operated barrel pump. 5. Install time delay relay in control circuit to provide approximately 60 seconds after blow. CAN ORDER SC1-2 WITH AFTER BLOW FROM BDI. PART # SPR13241B. MUST ORDER AIR NOZZLE SEPARATELY(SEE PG 10) 12

INSTALLATION INSTRUCTIONS INSTALLATION 1. Pump Close To Valve Panel (See Page 3): In most installations of this type, hoses are used to make all air and lubricant connections. Hose lengths must be adequate to allow movement of the pump during lubricant drum changes. Clean inside of hoses thoroughly before installing to remove foreign material. Tighten all hose connections securely using a thread lubricant and sealant. 2. Pump Remote From Valve Panel (See Page 4): Hoses are used to connect the air line to the pump and the pump to the reversing valve. Pipe is run from the reversing valve to within 30" of the valve panel with the final connection to the valve panel made with hose assemblies. Pipe size selection is important, as it will affect the operating pressure of the system. For guidance in selecting proper pipe size, see pipe sizing table in Figure 15. Pipe Sizing Table - Fig. 15 (Pump Remote From Valve Panel) PIPE SIZE OPERATING TEMPERATURE ( F) 50-90 32-50 0-32 1/2 60 FT. 40 FT. 20 FT. 3/4-60 FT. 30 FT. 1 - - 40 FT. NOTE: Longer lengths and larger diameter pipe is not recommended due to the fact that the compressed volume of lubricant, within a pipe, causes the valve manifold to cycle after the pump shuts down. This can result in excessive consumption of lubricant and/or cause the SC400 control to fault. Clean pip thorougly before installation to remove all scale, chips, dirt and burrs. Install pipe in protected locations and firmly clamp in place. Pipe threads should be cut clean and free of burrs. Use a good thread lubricant and sealant. Use 3000 pound forged steel fittings and schedule 80 pipe. Pull all connections tight. 3. For valve panel and spray lance locations - see page 14. 4. The Lubricant: High quality open gear lubricants are readily available that can be pumped and sprayed at low temperatures without requiring heat. Be sure that the lubricant selected will remain pumpable at the minimum operating temperature that will be encountered. 13

INSTALLATION & LAYOUT INSTALLATION LOCATION FOR VALVE PANEL LD12361 AND SPRAY LANCES LD9327 AS SHOWN IN FIGS. 16 & 17. ANGLE OF SPRAY 8 +/- 1/2 GEAR 30 +/- 10 GEAR PITCH CIRCLE GEAR GUARD SPRAY LANCE LD9327 GEAR GUARD FIGURE - 16 SPRAY LANCE LD9327 1-7/32 8 +/- 1/2 SPRAY LANCE LD9327 GEAR GUARD 30 +/- 10 SPRAY PATTERN CENTERLINE FIGURE - 17 PITCH CIRCLE - GEAR GEAR TOOTH CENTERLINE PITCH CIRCLE - PINION 30 +/- 10 8 +/- 1/2 CENTERLINE SPRAY PATTERN GEAR GUARD 1-7/32 14

START UP AND MAINTENANCE START UP PROCEDURE 1. Program the SC400 controller in accordance with instructions given. 2. Fill air line lubricator with light oil (SAE #10). 3. Adjust pump air regulator to obtain 1800 psi pump line pressure. 4. The DR4 reversing valve is set to reverse at 1500 psi at the factory. 5. Set the air regulator for the spray nozzles to 60-80 psi. Re-adjust for best spray. 6. To fill the two main supply lines to the measuring valves: a) Remove the pipe plugs from the last measuring valve. b) Start pump by pressing SC400 manual/reset button. c) Bleed (1) pint of lubrication from line 1 at the last measuring valve. d) Stop pump by pressing SC400 manual/reset button again. e) Insert pipe plug in last measuring valve (line that was purged). f) Start the pump again. Pressure will build up to operate the reversing valve. g) Follow steps c, d, and e for purging supply line 2. 7. After purging both suply lines, the system is ready to operate. Cycle the system manually until the spray nozzles are operating properly and the gear face is being completly covered with lubricant. 8. Coat the entire gear face (all teeth) with lubricant before starting up the mill. MAINTENANCE A. Too much water in the air filter drain bowl on the air control panel will make the filter ineffective and water will enter the pump. Empty it regularly, a drain cock is provided. If moisture in the air supply line requires frequent draining of the air filter we suggest installing automatic drain assembly. B. Be sure lube container has plenty of lubricant. Pumping from an empty drum may force air into system, causing difficulty in building pressure. C. Use clean lubricant. Foreign matter might clog valve manifold. D. Keep line stainers clean. These are usually installed in the line leading to the valve manifold. Establish regular intervals for this service. E. Inspect entire system regularly including hose (replace if damaged), connections (they should be tight), and the gear (see that the teeth are being properly lubricated). Check spray pattern frequently by inserting a piece of cardboard in front of the spray nozzles while the system is operating. Complete coverage of the gear face is important. F. Completely clean the system with a flushing solvent every year or two to extend its life. 15

TROUBLE SHOOTING SYSTEM DIAGNOSIS A. Pump doesn't operate* CONDITION CAUSE REMEDY 1. Insufficient air supply. 1. Adjust air pressure to 40/50 psi. 2. Timer control failing to operate solenoid shut-off. 3. Lubricant has hardened in drum. 2. Check wiring of system timer according to instructions and SC400 controller. Also check timer for proper programming. 3. Use smaller sized drums - diluent in some lubricants tends to evaporate causing lubricant to harden. B. Pump operates but doesn't build pressure. 1. Reservoir empty. 1. Check and renew lubricant supply. Purge air from lines. 2. Broken line. 2. Repair or replace as necessary. 3. Air in system. 3. Bleed lines and valves as described on page 15. C. Manifold valve indicator doesn't operate. 1. Lack of pressure. 1. Repair - see condition B. 2. Incorrect operation of reversing valve.. 3. Dirt in Dualine measuring valve. 2. Check valve condition by "shortcircuiting" it with two 3/8" pipe plugs installed in reversing valve discharge ports. Start air-operated barrel pump, and reversing valve will oscillate if properly adjusted for type of system. Clean any strainer in lines every six months. 3. Remove inlet bore plugs and piston. Clean bore by pouring solvent through it. Clean piston and re-assemble. 4. Locate obstruction, remove line 4. Plugged discharge line. and blow clean, or replace faulty section. *For more information on the air operated barrel pump, see Data Sheet # 35993. 16

Notes 17

Notes 18

Notes 19

Whatever your automatic lube requirement We have the solution! Series Progressive Injectors Dualine Flowmeters Oil Recovery Unit SureFire-PDI Refillable Single Point Let 80+ Years Of Experience Design Your Next Lube System BDI has been a manufacturer of automatic lubricating systems for over 80 years. We offer a complete line of pumps, valves, controllers, and accessories. Our pump line includes manual, air, electric, and hydraulic actuated models. Our valve offering is the most comprehensive in the industry. We manufacture oil and grease Dualine valves, series progressive modular valves, and injectors. We also offer air/oil mixing modules, oil flow meters, and single point lubricators. Your local distributor: BIJUR DELIMON INTERNATIONAL 2685 Airport Road Kinston, NC 28504 Tel. 800-227-1063 Fax: 252-527-9232 Website: www.bijurdelimon.com BIJUR DELIMON -DENCO FARVAL LUBESITE DL3100-R3 (05/16)