ulletin 617 Rev. Model R ommercial Riser Riser Manifold for ommercial pplications ulletin 617 Rev. vailable Sizes/Pressure Ratings: 1 1 / 2 (40mm) and 2 (50mm) Threaded - 250 psi (17,2 bar) Working Pressure 2 (50mm), 2 1 / 2 (65mm), & (0mm) Grooved - 00 psi (20,7 bar) Working Pressure 4 (0mm), 6 (150mm), & (200mm) Grooved - 00 psi (20,7 bar) Working Pressure Features 1. ast stainless steel body construction for threaded manifolds. 2. Painted, cast ductile iron body construction for grooved manifolds.. rass and galvanized Trim. 4. Factory assembled and pressure tested. 5. vailable with Test and rain Valves in various orifice sizes. Grooved end Test and rain valves are available as MTO. 6. Optional Pressure Relief Valve Kit available for all sizes. 7. Same take-out dimensions for the 1 1 /2 (40mm) and 2 (50mm) threaded sizes.. Same end-to-end dimensions for the 2 (50mm) through (200mm) grooved sizes.. pproved for installation in horizontal or vertical positions.. uilt in drain port allows hydrostatic testing without draining the system.. ¼ three-way valve allows for easy testing and replacing of pressure gauge. 12. edicated UL Listed, UL Listed and FM pproved Waterflow etector assures optimum sensitivity. See Table for triggering flow rates. Product escription The Model R ommercial Riser comes factory assembled with the necessary accessories for a cost effective, yet complete riser assembly. These assemblies are UL Listed, UL Listed and FM pproved as a unit. ast-on lettering on the manifold identifies manifold pipe size, flow direction, gauge and drain outlets, and UL Listing and FM pproval markings. The Model R ommercial Riser is available in four configurations (see Figures 1 and 2): asic Trim ommercial riser manifold assembly includes a cu- drain (ball) valve, and a dedicated waterflow detector containing two sets of SPT (Form ) contacts, having an electrical rating of @ 125/250 V/2.5 @ 24 V. See Table for triggering flow rates. asic Trim with Pressure Relief Kit ommercial riser manifold assembly includes a cu- drain (ball) valve, and a dedicated waterflow detector containing two sets of SPT (Form ) contacts, having an electrical rating of @ 125/250 V/2.5 @ 24 V. See Table for triggering flow rates. The nonadj (2) ustable Pressure Relief Kit will maintain system pressures below 175 psi (12,1 bar). asic Trim with Test and rain Valves Valve ommercial riser manifold assembly includes a cu- Test and rain Valve, and a dedicated waterflow detector containing two sets of SPT (Form ) contacts, having an electrical rating of @ 125/250 V/2.5 @ 24 V. See Table for triggering flow rates. The available test orifice size inside the Test and rain Valve are (hoose one): / (K-2.) (1) 7 /16 (K-4.2) 1 /2 (K-5.6) 17 /2 (K-.0) 5 / (K-.2) () /4 (K-14.0) () 15 (2) () /16 (K-16.) 1 5 (2) () /64 (K-22.4) 1 (2) () /64 (K-25.2) (1) Not available for 4, 6 and risers. (2) Not available for 1 1 /2 to risers. () Not available for 1 1 /2 to 2 threaded & 2 grooved risers. The Reliable utomatic Sprinkler o., Inc., Fairview Park rive, lmsford, New York 52
Fig. 1 Note:1 1/ 4 Grooved end Test and rain valves are available in various orifice size as Made To Order (MTO). 2.
Fig. 2 Note:1 1 /4 Grooved end Test and rain valves are available in various orifice size as Made To Order (MTO)..
Table 1 Threaded (See Fig. 1) Grooved (See Fig. 2) Manifold Pipe Size 1 1 /2 (40) 2 1 /2 (65) (0) 4 (0) 6 (150) (200) (27) (27) 12 /4 (24) 12 /4 (24) 12 /4 (24) 12 1 /2 (1) 12 1 /2 (1) 12 1 /2 (1) asic ssembly 1 /2 (22) 12 1 /4 () 15 (1) (4) 16 (406) 1 (457) 20 (50) 22 (55) 1 /4 () () (4) 4 /4 5 1 /4 () 6 1 /4 (15) (14) 7 /4 (17) 1 /2 (22) (20) imensions & s asic ssembly with Pressure Relief Kit. (.).1 (4.1).7 (4.) 12. (5.) 17.6 (.0) 21. (.7) 26. (12) 1.0 (14.1) 1 /2 (4) 1 /2 (4) 16 /4 16 /4 16 /4 16 /4 16 /4 16 /4 12 /4 (24) 1 /2 (4) 16 /4 17 1 /4 (4) 17 /4 (451) 1 1 /2 20 1 /2 (521) 22 1 /2 (572) 1 /4 () () (4) 4 /4 6 (152) 7 (17) 7 /4 (17) 1 /2 (22) (20).4 (4.7).2 (5.1). (6.0) 16.7 (7.6) 1. (.) 26.7 (12) 1. (14.4) 6.5 (16.6) Table 2 Threaded (See Fig. 1) Grooved (See Fig. 2) Manifold Pipe Size 1 1 /2 (40) 2 1 /2 (65) (0) 4 (0) 6 (150) (200) imensions & s asic ssembly asic ssembly with Test and rain Valve with Test and rain Valve & Pressure Relief Kit (27) (27) 12 /4 (24) 12 /4 (24) 12 /4 (24) 14 (56) 14 (56) 1 (62) 16 (406) 16 1 /2 (41) 17 1 /2 (445) 1 (457) 1 /4 (476) 22 (55) 25 1 /2 (64) 27 (66) 1 /4 () () (4) 4 /4 5 /4 (146) (22) 7 /4 (17) 1 /2 (22) (20).0 (4.5). (4.).7 (4.) 12. (5.) 17.6 (.0) 25. (.6) 0 (.6) 5. (16) 15 (1) 15 (1) (4) (4) (4) 1 1 /2 1 1 /2 1 1 /2 16 (406) 16 1 /2 (41) 17 1 /2 (445) 1 (457) 1 /4 (476) 22 (55) 25 1 /2 (64) 27 (66) 1 /4 () () (4) 4 /4 5 /4 (146) (22) 7 /4 (17) 1 /2 (22) (20). (4.).6 (5.). (6.0) 16.1 (7.) 17.0 (7.7) 26 (.) 1 (14.1) 6. (16.5) 4.
asic Trim with Test and rain Valve & Pressure Relief Kit ommercial riser manifold assembly includes a cu- Test and rain Valve, and a dedicated waterflow detector containing two sets of SPT (Form ) contacts, having an electrical rating of @ 125/250 V/2.5 @ 24 V. See Table for triggering flow rates. The non-adjustable Pressure Relief Kit will maintain system pressures below 175 psi (12,1 bar). The available test orifice size inside the Test and rain Valve are (hoose one): / (K-2.) (1) 7 /16 (K-4.2) 1 /2 (K-5.6) 17 /2 (K-.0) 5 / (K-.2) () /4 (K-14.0) () 15 (2) () /16 (K-16.) 1 5 (2) () /64 (K-22.4) 1 (2) () /64 (K-25.2) (1) Not available for 4, 6 and risers. (2) Not available for 1 1 /2 to risers. () Not available for 1 1 /2 to 2 threaded & 2 grooved risers. Installation 1. ttach the pressure gauge as shown in Figures 1-4. 2. Install the manifold with the flow arrow pointing towards the SYSTM side using threaded fittings or grooved pipe couplings.. onnect the appropriately sized drain line. 4. nsure that the drain valve is in the LOS position. 5. Place the sprinkler system in service. 6. Installation must comply with NFP, Section.16.4.2 aution: utomatic sprinkler systems having non-fire protection connection (permitting continual water flow) require dielectric fittings, according to NFP sect. 4-6, when dissimilar metal piping materials are joined. Note: Use a non-hardening pipe joint compound, or teflon tape. Follow the manufacturer s instructions when using grooved pipe couplings. Listings and pprovals 1. Listed by Underwriters Laboratories Inc. and UL Listed. 2. Factory Mutual pproved.. NY M 25-- ngineering Specification [Model R ommercial Riser ssembly] shall be [UL Listed][UL Listed] [Factory Mutual (FM) pproved] for horizontal or vertical installation as a one-piece, fabricated assembled unit. The [Model R ommercial Riser ssembly] shall consist of a (choose one): 1 1 /2 (40 mm) cast, non-welded stainless steel body with threaded end connections 2 (50 mm) cast, non-welded, stainless steel body with threaded end connections 2 (50 mm) cast, non-welded, ductile iron body with 2 1 /2 (65 mm) cast, non-welded, ductile iron body with (0 mm) cast, non-welded, ductile iron body with 4 (0 mm) cast, non-welded, ductile iron body with 6 (150 mm) cast, non-welded, ductile iron body with (200 mm) cast, non-welded, ductile iron body with having all brass and galvanized trim. The manifold piping shall clearly identify the manifold s pipe size, flow direction, UL Listing/ UL Listing/ FM pproval, drain, and gauge outlets. built-in drain port shall be available to permit hydrostatic testing without draining the system. This drain port shall be sized per the following: 1 (25mm) for 1½ (40mm) and 2 (50mm) sizes. 1 1 /4 (2 mm) for 2½ (65mm), and (0mm) sizes. 2 (50mm) for 4 (0mm), 6 (150mm) and (200mm) sizes. Take-out dimensions shall be the same for the 1½ (40mm) and 2 (50mm) threaded sizes. nd-to-end dimensions shall be the same for the 2 (50mm) through (0mm) grooved sizes. ssembly shall have a working pressure rating of [250 psi (17,2 bar) (for 1½ (40mm) and 2 (50mm) threaded manifold assemblies)] [00 psi (20,7 bar) (for 2 through grooved manifold assemblies)]. nd-to-end dimensions shall be the same for the 4 (0mm) through (200mm) grooved sizes. ssembly shall have a working pressure rating of [00 psi (20,7 bar) (for 4 (0mm) through (200mm) grooved manifold assemblies)]. Table Manifold Sizes 1½ (40mm), 2 (50mm), 2½ (65mm) & (0mm) 4 (0mm), 6 (150mm), & (200mm) Triggering Flow Rate - GPM (LPM) 4 (15) to () 4 (15) to () 5.
Ordering Information: Model R ommercial Riser ssembly Part Number ode Key 1.5NT 1.5MT 2NT 2MT 2G 2.5G G 4G 6G G 1.5NT = 1 1 /2 (40 mm) NPT Threaded ssembly 1.5MT = 1 1 /2 (40 mm) Metric Threaded ssembly 2NT = 2 (50 mm) NPT Threaded ssembly 2MT = 2 (50 mm) Metric Threaded ssembly 2G = 2 (50 mm) 2.5G = 2 1 /2 (65 mm) G = (0 mm) 4G = 4 (0 mm) 6G = 6 (150mm) G = (200 mm) T2 (K-2.) (1) T42 (K-4.2) T56 (K-5.6) T0 (K-.0) T2 (K-.2) () T140 (K-14.0) () (2) () T16 (K-16.) (2) () T224 (K-22.4) (2) () T252 (K-25.2) = asic ssembly T2 = W / K-2. Test & rain Valve T42 = W / K-4.2 Test & rain Valve T56 = W / K-5.6 Test & rain Valve T0 = W / K-.0 Test & rain Valve T2 = W / K-.2 Test & rain Valve () T140 = W / K-14.0 Test & rain Valve () (2) () T16 = W / K-16. Test & rain Valve (2) () T224= W / K-22.4 Test & rain Valve (2) () T252 = W / K-25.2 Test & rain Valve (1) Not available for 4, 6 and risers. (2) Not available for 1 1 /2 to risers. () Not available for 1 1 /2 to 2 threaded & 2 grooved risers. For Grooved end Test and rain valves (See note ) 0 1 2 0 = ssembly without Pressure Relief Kit Water etector - UL & FM 1 = ssembly with Pressure Relief Kit Water etector - UL & FM 2 = ssembly without Pressure Relief Kit Water etector - UL = ssembly with Pressure Relief Kit Water etector - UL xample #1: 1.5NT 1 (1½ (40mm) Model R ommercial Riser ssembly with NPT female inlet and outlet threads, basic trim with installed Pressure Relief Kit). xample #2: G T56 0 ( (0mm) Model R ommercial Riser ssembly with grooved ends, basic trim with Test and rain Valve having a 5.6 K factor, without a Pressure Relief Kit) xample #: 6G T0 0 (6 (150mm) Model R ommercial Riser ssembly with grooved ends, basic trim with Test and rain Valve having a.0 K factor, without a Pressure Relief Kit) Notes: 1. ll Model R ommercial Riser ssemblies come with a 00 psi (20,7 bar) UL Listed and FM pproved pressure gauge for 175 psi (12,1 bar) applications. If the Model R ommercial Riser ssembly is to be installed in a 00 psi (20,7 bar) application, please purchase a 600 psi (41,4 bar) (P/N 24005) pressure gauge. This gauge may or may not be UL Listed and/or FM pproved at the time of purchase. 2. If required, Pressure Relief Kits may also be installed in the field. Please contact Reliable s ustomer Service epartment for details.. 1 1 /4 and 2 Grooved end Test and rain valves are available in various orifice size K factor as MTO. Please contact Reliable Service epartment for details. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection ssociation, Factory Mutual Research orporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 0 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, anada and foreign countries. Manufactured by The Reliable utomatic Sprinkler o., Inc. (00) 41-15 Sales Offices (00) 4-6051 Sales Fax (14) 2-2042 orporate Offices www.reliablesprinkler.com Internet ddress Recycled Paper Revision lines indicate updated or new data..g. Printed in U.S.. 02/12 P/N 704