Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

Similar documents
630 Series Power Supplies

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG

ACCESS & EGRESS POWER SUPPLY & DOOR CONTROLS SOLUTIONS. The lock behind the system. SDCSecurity.com

Power Supplies DORMA PS

Excel Series Value Engineered Access Hardware

Accessories 286 SDC SECURITY DOOR CONTROLS

SECURITY DOOR CONTROLS

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

cel SECURITY DOOR CONTROLS Value Engineered Access Hardware sdcsecurity.com Power Supplies Exit Switches

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

AccuPower AQU126B Installation Instructions

AccuPower AQU128B Installation Instructions

Installation Instructions

SAFE & SECURE ACTUATOR PRODUCT MANUAL

SECTION DC POWER SUPPLY/BATTERY CHARGER

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

SmartLock Accessories

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

Installation Instructions

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

LOCKNETICS Power Supplies. 510 Series Power Supply Controller 12 and 24 VDC. 505 Series Power Supply. 505DE Series Delayed Egress Controller

AL600ULX Series. Power Supply/Charger Installation Guide

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

Uninterruptible Power Systems

POWER SUPPLIES & RECTIFIERS

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Uninterruptible Power Systems

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

3 Uninterruptible Power Systems

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

Power Supply EL

SECTION MOTOR CONTROL

3 Uninterruptible Power Systems

Illuminator Series CR NEMA 3R

2904 Power Supply Installation Instructions I-EA00041

INSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S

Transfer switch GTEC open or delayed transition

SURE-TRIP OEM RELACEMENT TRIP UNIT

PRODUCTS: POWER SUPPLY

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

Plena 24 VDC Battery Charger. Installation and User Instructions PLN-24CH10

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

MaxPak Plus Analog DC V S Drive

ValveMate 7000 Controller Operating Manual

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

RP-4000 Reserve Power Control

PS24/AC Volt AC 16 Amp

OTEC Transfer switch open transition

3 Uninterruptible Power Systems

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Transfer switch OTEC and OTECSE open transition

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

Sola 3000 Guide Specifications

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Product Installation Document

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Gate & Door Controller with LCD and Intelligent Technology

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Power Product Specifications

3 Uninterruptible Power Systems

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

Transfer switch OTEC open or delayed transition

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

E.S.P. Embedded Sensing Probes for Motor Brushes

Industrial Power Supplies

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

2 Uninterruptible Power Systems

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

"EH SERIES" POWER SUPPLIES "PS SERIES" POWER SUPPLIES EH SERIES PUBLIC SAFETY POWER SUPPLIES PS SERIES PUBLIC SAFETY POWER SUPPLIES

Power Switching Devices

10A 15A 25A 40A 60A 20A 30A

Special Specification 6058 Battery Back-Up System for Signal Cabinets

INSTALLATION INSTRUCTIONS

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

MODEL 422 Submersible Pump Controller

Eclipse Plus VA UPS and Surge Suppressor User s Manual

SURE TRIP RETRO KITS

Application Engineering Europe

Cat/DCG-6D1I/07-08/03/Ver 1 Page 2/10

7000 series. Industrial Electropneumatic Timing Relay AGASTAT. Design Features. On-delay model 7012 (delay on pickup) Design & Construction

DIESEL Engine Fire Pump Controllers Features

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

Transcription:

Security Door Controls & Door Controllers 5 SDC Access Control Power Supplies have been developed specifically to support access controls and electric locking hardware with clean, consistent power. Combined with SDC s door controllers, there s a convenient and reliable way to wire, set dip switches, and install reliable power for virtually any door control application. The circuitry design is ideal for the inductive loads generated by access control hardware for high performance and longevity. The modular design is built around several different control modules to meet the most demanding component interface and control logic requirements. UL Listed filtered and regulated DC power, control logic, component interface, alarm interface and battery back up modules meet the demanding requirements of requirements for single and multiple access controlled openings. 238 SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM

602RF Series 1 Amp Modular Access Control All SDC power supplies are equipped with a high performance transformer and highly reliable electronic components. Filtering and output voltage regulation provide protection and ensure the longevity of all system components. With the addition of SDC programmable controllers or relay modules, the user-friendly modular designs ensure versatility, interface capability and easy installation of electric locking devices, access controls and related safety equipment. 602RF* FEATURES Fire/Life Safety A fire alarm input provides simultaneous release of all fail safe locks and door holders in case of an emergency. Door Control Modules SDC relay modules may be incorporated in the power supplies to meet virtually any application requirement, for single or multiple door control. Input AND Protection The AC input voltage is circuit breaker protected and the secondary output is PTC protected. System Status LED status indicators provide information regarding the AC input, DC output, and battery back up status. s for remote annunciation are available. Low Battery Disconnect Batteries are disconnected from the output circuit prior to deep discharge preventing battery destruction. Battery Charging A separate PTC protected charging output provides 13.5 or 27 volts to fully charge the batteries. The secondary output is always precisely maintained at 12 or 24VDC to protect locking devices and components from over voltage while the batteries are charging. The specified secondary output current is also maintained while batteries are charging. De-rating of the secondary output current is not required when charging batteries. Class 2 s To simplify installations that do not require conduit, a Class 2 output is standard and a 6-foot power cord is optional for the 115VAC input where permitted by code. Modular Design Door control relay modules are available to meet virtually any application need. All wiring for lock hardware, access controls remote control and monitoring is terminated at one central location. Installation and troubleshooting is simplified. Modules may be factory installed or ordered separately for field installation as needed. All modules are individually fused for protection of multiple station systems. MODELS 602RFL 602RFL (less cabinet) 602RF, plus 12 W x 12 H x 3.75 D Cabinet 602RFA, plus 16 W x 14 H x 6.5 D Cabinet * shown with optional batteries SDC SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM FIELD 12 24 SELECTABLE YEAR 5 WARRANTY 239

SPECIFICATIONS Electrical Input Weight 115VAC, 600 ma, 50/60 Hz Field Selectable 12/24VDC, 1 Amp 13.5/27VDC, 250 ma 8.5 lbs Mechanical Cabinet 602RF: 12 x 12 x 4, 20 GA 602RFA: 16 x 14 x 6.5, 16 GA SDC power supplies equipped with batteries provide continuous operation of access controls, locking devices and peripheral components during a power failure. See Table 2 to determine battery requirements for standby power. PRODUCT SKU SAMPLE: 602RF 12VR UR1 HOW TO ORDER 1 SPECIFY MODEL 602RFL 1 Amp, Class 2, Less Cabinet 602RF 1 Amp, Class 2 12 W Cabinet 602RFA 1 Amp, Class 2 16 W Cabinet TABLE 1 CONTROL MODULE CAPACITY* : 602RF 602RFA Battery Qty. 0-2 3-4 0-2 3-4 RB12V4 RB12V4 FB4 2 2 2 2 12VR 2 1 2 1 2 SPECIFY OPTIONS MR PS-1 PS-1A Cover Mounted Manual Reset Switch for Fire/Emergency Release System On-Off Push Switch inside Power Supply Enclosure System On-Off Push Switch on Enclosure Cover 14-2 7 Day Skip a Day Programmable Timer Automatically unlocks and locks all doors or specific doors on programmed days only. PC KL 220V/230V 6 ft. Power Cord Recommended for 1 Amp, eliminating the need for AC conduit. Key Lock Cover 230VAC, 50/60Hz TABLE 2: 12VDC STANDBY POWER 5 Ah Battery Qty 1 2 Amp Hours 5Ah 10Ah PSM 1 1 1 1 UR-1 4 2 4 2 CR-4 2 1 2 1 ACM-1 2 1 2 1 * Total combined load of modules and access control hardware may not exceed 1 amp. 0.25 20 40 0.50 8.5 20 0.75 5.5 12 1.00 3.8 8.5 3 SPECIFY CONTROL MODULES 12VR FB-4 PSM UR1 CR4 12VDC Regulated and Filtered Module Four 2 Amp fuse protected outputs Remote Monitoring Module Universal Door Controller Control Relay - 4 Independent DPDT Relays ACCESSORIES BACKUP BATTERIES SDC power supplies equipped with batteries provide continuous operation of access controls, locking devices and peripheral components during a power failure. ACM-1 Access Control Module see page 257 for more info RB12V4 12V/5Ah Battery, RB12V7 12V/8Ah Battery, 240 SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM

TM 631RF Series 1.5 Amp Modular Access Control The SDC 631RF Power Supplies have been developed specifically to support electric locks and access controls. The high performance, heavy-duty circuitry is ideal for inductive loads and multi-door applications. The modular design is built around several different application control modules to meet your specific needs for virtually any electric lock system. SDC power supplies are designed to provide a well organized installation for individual or multidoor systems that may include locking devices, access controls, station controls and consoles for remote control, annunciation and fire/life safety system interfaces. FEATURES Filtered and Regulated The output filtering stabilizes the DC output voltage and eliminates AC line noise. The solid state regulator maintains the selected output voltage at 12VDC or 24VDC regardless of the output load changes, including battery charging. Field Selectable 12 or 24VDC The output is field selectable for 12 or 24VDC output. 250 ma A separate PTC protected, battery charger output provides 13.5VDC or 27VDC. LED System Status Indicator Amber - AC and DC voltages are OK Green - No DC output Red - No AC input, powered by batteries Class 2 s Where permitted by code, conduit is not required when using Class 2 outputs. 631RF* Emergency Release Input The Fire/Life Safety emergency release input is standard on all SDC power supplies. Large Heavy Gauge Enclosure Model 631RFA is housed in a 16 gauge, 16 W x 14 H x 6.5 D cabinet large enough to accommodate several additional modules and four 8Amp hour batteries with plenty of room for wiring. Low Battery Disconnect Batteries are disconnected from the output circuit prior to deep discharge preventing battery destruction. Isolated Charging Circuit While the charging output is 13.5VDC or 27VDC, the secondary output is unaffected and precisely maintained at the selected 12 or 24VDC. This ensures system components are powered by their specified voltage. The secondary output current is maintained at the full 1.5 Amp capacity and is not de-rated when charging batteries. 631RFA* 631RFL MODELS 631RFL (less Cabinet) 631RF, plus 12 W x 12 H x 4 D Cabinet 631RFA, plus 16 W x 14 H x 6.5 D Cabinet * shown with optional batteries SDC SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM SIA Security Industry Finest ISC Expo FIELD 12 24 SELECTABLE YEAR 5 WARRANTY 241

SPECIFICATIONS Electrical Mechanical Input 115VAC @ 800 ma, 50/60 Hz Fused 631RF Cabinet 12 W x 12 H x 4 D, Steel 20 Ga. Secondary Weight Selectable 12VDC or 24VDC @ 1.5 Amp, Poly Fuse Protected, Class 2 250mA @ 13.5 or 27VDC, PTC Protected 8.8 lbs 631RFA Cabinet 16 W x 14 H x 6.5 D, Steel 16 Ga. SDC power supplies equipped with batteries provide continuous operation of access controls, locking devices and peripheral components during a power failure. See Table 2 & 3 to determine battery requirements for standby power. TABLE 1: CONTROL MODULE CAPACITY* : 631RF 631RFA Battery Qty. 0-2 3-4 0-2 3-4 RB12V4 HOW TO ORDER RB12V7 FB4 4 2 4 4 12VR 1 1 1 1 PSM 1 1 1 1 UR-1 4 2 4 2 UR2-4 NA NA 2 1 UR4-8 NA NA 2 1 CR-4 2 1 4 2 ACM-1 2 1 4 2 PB-8, PB-16 1 1 1 1 * Total combined load of modules and access control hardware may not exceed 1.5 amp. TABLE 2: 12VDC STANDBY POWER 5 Ah Battery Qty 1 2 4 Amp Hours 5Ah 10Ah 20Ah 0.25 20 40 80 0.50 8.5 20 40 1.00 3.8 8.5 20 1.50 2.3 45.5 12 8 Ah Battery Qty 1 2 4 Amp Hours 8Ah 16Ah 32Ah 0.25 36.7 85 175 0.50 15 36 85 1.00 6.5 14.4 36 1.50 4 9 21 PRODUCT SKU SAMPLE: 631RF PS-1 UR1 TABLE 3: 24VDC STANDBY POWER 5 Ah Battery Qty 2 4 Amp Hours 5Ah 10Ah Power Back-up Time in Hrs 0.25 20 40 0.50 8.5 20 1.00 3.8 8.5 1.50 2.3 4.5 8 Ah Battery Qty 2 4 Amp Hours 8Ah 16Ah Power Back-up Time in Hrs 0.25 36.7 85 0.50 15 36 1.00 6.5 14.4 1.50 4 9 1 SPECIFY MODEL 631RFL 1.5 Amp, Class 2, Less Cabinet 631RF 1.5 Amp, Class 2 12 W Cabinet 631RFA 1.5 Amp, Class 2 16 W Cabinet 2 SPECIFY OPTIONS PS-1 PS-1A System On-Off Push Switch inside Enclosure System On-Off Push Switch on Enclosure Cover 14-2 7 Day Skip a Day Programmable Timer PC KL 220V/230V 6 ft. Power Cord Key Lock Cover 230VAC, 50/60Hz 3 SPECIFY CONTROL MODULES 12VR FB-4 PSM UR1 UR2-4 UR4-8 CR4 ACM-1 PB-8 PB-16 12VDC Regulated and Filtered Module Four 2 Amp fuse protected outputs Remote Monitoring Module Universal Door Controllers Two Station Door Controllers Four Station Door Controllers Control Relay - 4 Independent DPDT Relays Access Control Module 8 Amp Power Booster 16 Amp Power Booster see page 257 for more info on control modules ACCESSORIES SDC power supplies equipped with batteries provide continuous operation of access controls, locking devices and peripheral components during a power failure. See Table 2 & 3 to determine battery requirements for standby power. 242 RB12V4 12V/5Ah Battery, 631RF Capacity, 4 Max RB12V7 12V/8Ah Battery, 631RFA Capacity, 4 Max SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM

TM 632RF Series 2 Amp Modular Access Control The SDC 632RF Power Supplies have been developed specifically to support electric locks and access controls. The high performance, heavy-duty circuitry is ideal for inductive loads and its modular design provides a well organized installation for individual or multi-door systems that may include locking devices, access controls, station controls and consoles for remote control, annunciation and fire/life safety system interfaces. 632RF* FEATURES Filtered and Regulated The output filtering stabilizes the DC output voltage and eliminates AC line noise. The solid state regulator maintains the selected output voltage at 12VDC or 24VDC regardless of the output load changes, including battery charging. Field Selectable 12 or 24VDC The output is field selectable for 12 or 24VDC output. A separate PTC protected, battery charger output provides 13.5VDC or 27VDC. LED System Status Indicator Amber - AC and DC voltages are OK Green - No DC output Red - No AC input, powered by batteries Emergency Release Input (Standard) A signal input from the fire life safety system turns off the secondary output releasing all failsafe locks. When not used for emergency release, this input may be used as main on-off control. Large Heavy Gauge Enclosure Model 632RFA is housed in a 16 gauge, 16 W x 14 H x 6.5 D cabinet large enough to accommodate several additional modules and six 8 Amp hour batteries with plenty of room for wiring. Class 2 Where permitted by code, conduit is not required for the Class 2 output. * shown with optional batteries SDC SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM SIA Security Industry Finest ISC Expo California Compliant Manual Reset of Emergency Release and AC Power Loss (Optional) When this feature is required, should an AC power loss occur or the emergency release input is actuated, personnel must restore secondary output power manually at the power supply after the emergency release signal is reset and/or AC power is restored. Low Battery Disconnect (Standard) Batteries are disconnected from the output circuit prior to deep discharge preventing battery destruction. Isolated Charging Circuit (Standard) While the charging output is 13.5VDC or 27VDC, the secondary output is unaffected and precisely maintained at the selected 12 or 24VDC. This ensures system components are powered by their specified voltage.the secondary output current is maintained at the full 2 Amp capacity and is not de-rated when charging batteries. MODELS 632RFL (less cabinet) 632RFL 632RF, plus 12 W Cabinet 632RFA, plus 16 WCabinet FIELD 12 24 SELECTABLE YEAR 5 WARRANTY 243

SPECIFICATIONS Electrical Input Secondary Weight 115VAC @ 800mA, 50/60 Hz, Fused. (220/230VAC 50/60 Hz optional) Selectable 12VDC or 24VDC @ 2 Amp, poly fuse protected, Class 2 PTC protected 250mA @ 13.5 or 27VDC 8.8 lbs Mechanical 632RF Cabinet 632RFA Cabinet 12 W x 12 H x 4 D, Steel 20 Ga. 16 W x 14 H x 6.5 D, Steel 16 Ga. SDC power supplies equipped with batteries provide continuous operation of access controls, locking devices and peripheral components during a power failure. See Table 2 & 3 to determine battery requirements for standby power. TABLE 1: CONTROL MODULE CAPACITY* TABLE 2: 12VDC STANDBY POWER TABLE 3: 24VDC STANDBY POWER : 632RF 632RFA Battery Qty. 0-2 3-6 0-2 3-4 RB12V4 RB12V7 FB4 4 2 4 4 12VR 4 2 4 4 PSM 1 1 1 1 UR-1 4 2 4 2 UR2-4 NA NA 2 1 UR4-8 NA NA 2 1 CR-4 2 1 4 2 ACM-1 2 1 4 2 PB-8, PB-16 2 2 2 2 * Total combined load of modules and access control hardware may not exceed 2 amp. HOW TO ORDER 5 Ah Battery Qty 1 2 4 Amp Hours 5Ah 10Ah 20Ah 0.25 19.6 49 124 0.50 7.8 20 49 1.00 3.8 11.3 19.4 1.50 1.8 4.5 11.3 8 Ah Battery Qty 1 2 4 6 Amp Hours 8Ah 16Ah 32Ah 48Ah 0.25 36.7 85 175 400 0.50 15 36 85 157 1.00 6.5 14.4 36 62 1.50 4 9 21 36 PRODUCT SKU SAMPLE: 632RFA PS-1A UR4-8 5 Ah Battery Qty 2 4 Amp Hours 5Ah 10Ah Power Back-up Time in Hrs 0.25 250 40 0.50 8.5 20 1.00 3.8 8.5 1.50 2.3 5.5 8 Ah Battery Qty 2 4 6 Amp Hours 8Ah 16Ah 24Ah Power Back-up Time in Hrs 0.25 36.7 85 158 0.50 15 36 62.7 1.00 6.5 14.4 24.8 1.50 4 9 15 1 SPECIFY MODEL 632RFL 2 Amp, Class 2, Less Cabinet 632RF 2 Amp, Class 2, 12 W Cabinet 632RFA 2 Amp, Class 2, 16 W Cabinet 2 SPECIFY OPTIONS MR PS-1 PS-1A Cover Mounted Manual Reset Switch for Fire/Emergency Release System On-Off Push Switch inside Enclosure System On-Off Push Switch on Enclosure Cover 14-2 7 Day Skip a Day Programmable Timer PC KL 6 ft. Power Cord Key Lock Cover 220V/230V 230VAC, 50/60Hz 3 SPECIFY CONTROL MODULES 12VR FB-4 PSM UR1 UR2-4 UR4-8 CR4 ACM-1 PB-8 PB-16 12VDC Regulated and Filtered Module Four 2 Amp fuse protected outputs Remote Monitoring Module Universal Door Controllers Two Station Door Controllers Four Station Door Controllers Control Relay - 4 Independent DPDT Relays Access Control Module 8 Amp Power Booster 16 Amp Power Booster see page 257 for more info on control modules 632RF x PC x 2 RB12V4 ACCESSORIES RB12V4 12V/5Ah Battery, 632RF Capacity, 4 Max 244 RB12V7 12V/8Ah Battery, 632RFA Capacity, 6 Max RB12V4 RB12V7 632RFA x UR4-8 x 4 RB12V7 SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM

TM 634RF 4 Amp The SDC 634RF Power Supplies have been developed specifically to support electric locks and access controls. The high performance, heavy-duty 4 Amp circuitry is ideal for inductive loads and multi-door applications. The modular design is built around several different application control modules to meet your specific needs for virtually any electric lock system. Documentation is provided to ensure a well organized installation for individual or multi-door systems that may include locking devices, access controls, station controls and consoles for remote control, annunciation and auxiliary emergency release interface. SDC 600 Series power supplies are manufactured according to Quality Assurance standards. 634RF* FEATURES Filtered and Regulated The output filtering stabilizes the DC output voltage and eliminates AC line noise. The solid state regulator maintains the selected output voltage at 12VDC or 24VDC regardless of the output load changes, including battery charging. Field Selectable 12 or 24VDC The output is field selectable for 12 or 24VDC output. Class 2 The 634RF may be configured to use one 4 Amp output or two 2 Amp, Class 2 outputs. Where permitted by code, conduit is not required for low voltage wiring when using Class 2 outputs. The total current draw from all outputs must not exceed 4 Amps. LED System Status Indicator Amber - AC and DC voltages are OK Green - No DC output Red - No AC input, powered by batteries Large Heavy Gauge Enclosure Model 634RF is housed in a 16 gauge, 16 W x 14 H x 6.5 D cabinet large enough to accommodate several additional modules and six 8 Amp hour batteries with plenty of room for wiring. A separate PTC protected, battery charger output provides 13.5VDC or 27VDC. Emergency Release Input (Standard) A signal input from the fire life safety system turns off the secondary output releasing all failsafe locks. When not used for emergency release, this input may be used as main on-off control. California Compliant Manual Reset of Emergency Release and AC Power Loss (Optional) When this feature is required, should an AC power loss occur or the emergency release input is actuated, personnel must restore secondary output power manually at the power supply after the emergency release signal is reset and/or AC power is restored. Low Battery Disconnect (Standard) Batteries are disconnected from the output circuit prior to deep discharge preventing battery destruction. Isolated Charging Circuit (Standard) While the charging output is 13.5VDC or 27VDC, the secondary output is unaffected and precisely maintained at the selected 12 or 24VDC. This ensures system components are powered by their specified voltage. The secondary output current is maintained at the full 4 Amp capacity and is not derated when charging batteries. MODEL 634RF 4 Amp * shown with optional batteries SDC SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM SIA Security Industry Finest ISC Expo FIELD 12 24 SELECTABLE YEAR 5 WARRANTY 245

SPECIFICATIONS Input 1 Amp @115VAC 50/60 Hz (230VAC 50/60Hz Optional, Not UL listed) 500 ma @ 13.5 or 27VDC Input Protection Secondary 1 Amp, Manually Resettable Circuit Breaker Selectable One, 4 Amp @ 12VDC or 24VDC or Two, Class 2, 2 Amp @12VDC or 24VDC Protection Dimensions Auto Resetting Poly Fuse 16 W x 14 H x 6.5 D Battery Protection Auto Resetting Poly Fuse per Material 16 Gauge Steel HOW TO ORDER 1 SPECIFY MODEL 634RF 4 Amp One 4 Amp or Two 2 Amp Class 2 s Standard MR PS-1 PRODUCT SKU SAMPLE: 634RF 14-2 UR4-8 2 SPECIFY OPTIONS Cover Mounted Manual Reset Switch for Fire/Emergency Release System On-Off Push Switch inside Enclosure Weight 20.3 lbs TABLE 1: CONTROL MODULE CAPACITY * : 634RF Battery Qty. 0-2 3-6 RB12V7 FB4 8 4 12VR 4 4 PSM 1 1 UR-1 4 4 UR2-4, UR4-8 2 1 CR-4 4 2 ACM-1 4 2 PS-1A System On-Off Push Switch on Enclosure Cover 14-2 7 Day Skip a Day Programmable Timer PC KL 220V/230V 6 ft. Power Cord Key Lock Cover 230VAC, 50/60Hz 3 SPECIFY CONTROL MODULES 12VR FB-4 PSM UR1 12VDC Regulated and Filtered Module Four 2 Amp fuse protected outputs Remote Monitoring Module Universal Door Controllers PB-8, PB-16 4 4 * Total combined load of modules and access control hardware may not exceed 4 amp. TABLE 2: 12VDC STANDBY POWER 8 Ah Battery Qty 1 2 4 6 Amp Hours 8Ah 16Ah 32Ah 48Ah 2 3 6.5 15 19 2.5 2.3 5 11.5 15 3 1.8 4 9 12.5 3.5 1.5 3.4 7.5 11 4 1.3 2.8 6.5 6.1 UR2-4 UR4-8 CR4 Two Station Door Controllers Four Station Door Controllers Control Relay - 4 Independent DPDT Relays TABLE 3: 24VDC STANDBY POWER 8 Ah Battery Qty 2 4 6 Amp Hours 8Ah 16Ah 24Ah 246 ACM-1 PB-8 PB-16 Access Control Module 8 Amp Power Booster 16 Amp Power Booster see page 257 for more info on control modules ACCESSORIES RB12V7 12VDC, 8 Amp Hour Battery 634RF x 2-UR4-8 x 2 RB12V7 2 3 6.5 11 2.5 2.3 5 8.3 3 1.8 4 6.5 3.5 1.5 3.4 5.5 4 1.3 2.8 4.8 SDC power supplies equipped with batteries provide continuous operation of access controls, locking devices and peripheral components during a power failure. See Table 2 & 3 to determine battery requirements for standby power. SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM

TM 636RF 6 Amp The SDC 636RF Power Supplies have been developed specifically to support electric locks and access controls. The high performance, heavy-duty 6 Amp circuitry is ideal for inductive loads and multi-door applications. The modular design is built around several different application control modules to meet your specific needs for virtually any electric lock system. Documentation is provided to ensure a well organized installation for individual or multi-door systems that may include locking devices, access controls, station controls and consoles for remote control, annunciation and auxiliary emergency release interface. SDC 600 Series power supplies are manufactured according to Quality Assurance standards. 636RF* FEATURES Filtered and Regulated The output filtering stabilizes the DC output voltage and eliminates AC line noise. The solid state regulator maintains the selected output voltage at 12VDC or 24VDC regardless of the output load changes, including battery charging. Field Selectable 12 or 24VDC The output is field selectable for 12 or 24VDC output. Class 2 The 636RF may be configured to use one 6 Amp output or three 2 Amp, Class 2 outputs. Where permitted by code, conduit is not required for low voltage wiring when using Class 2 outputs. The total current draw from all outputs must not exceed 6 Amps. A separate PTC protected, battery charger output provides 13.5VDC or 27VDC. LED System Status Indicator Amber - AC and DC Voltages are OK Green - No DC Red - No AC Input, Powered by Batteries Low Battery Disconnect (Standard) Batteries are disconnected from the output circuit prior to deep discharge preventing battery destruction. Large Heavy Gauge Enclosure Model 636RF is housed in a 16 gauge, 16 W x 14 H x 6.5 D cabinet large enough to accommodate several additional modules and six 8 Amp hour batteries with plenty of room for wiring. Emergency Release Input (Standard) A signal input from the fire life safety system turns off the secondary output releasing all failsafe locks. When not used for emergency release, this input may be used as main on-off control. California Compliant Manual Reset of Emergency Release and AC Power Loss (Optional) When this feature is required, should an AC power loss occur or the emergency release input is actuated, personnel must restore secondary output power manually at the power supply after the emergency release signal is reset and/or AC power is restored. Isolated Charging Circuit (Standard) While the charging output is 13.5VDC or 27VDC, the secondary output is unaffected and precisely maintained at the selected 12 or 24VDC. This ensures system components are powered by their specified voltage. The secondary output current is maintained at the full 6 Amp capacity and is not derated when charging batteries. MODEL 636RF 6 Amp * shown with optional batteries SDC SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM SIA Security Industry Finest ISC Expo FIELD 12 24 SELECTABLE YEAR 5 WARRANTY 247

SPECIFICATIONS Input Input Protection Secondary Protection Protection Dimensions Material Weight 1 Amp @115VAC 50/60 Hz (230VAC 50/60Hz Optional, Not UL listed) 1 Amp, Manually Resettable Circuit Breaker Selectable One, 6 Amp @ 12VDC or 24VDC or Three, Class 2, 2 Amp @12VDC or 24VDC Auto Resetting Poly Fuse per 500 ma @ 13.5 or 27VDC Auto Resetting Poly Fuse 16 W x 14 H x 6.5 D 16 Gauge Steel 25.2 lbs TABLE 1: CONTROL MODULE CAPACITY * : 636RF Battery Qty. 0-2 3-6 RB12V7 FB4 8 4 12VR 4 4 PSM 1 1 UR-1 4 4 UR2-4, UR4-8 2 1 CR-4 4 2 ACM-1 4 2 PB-8, PB-16 4 4 * Total combined load of modules and access control hardware may not exceed 6 amp. HOW TO ORDER 1 SPECIFY MODEL 636RF 6 Amp One 6 Amp or Three 2 Amp Class 2 s MR PS-1 PS-1A PRODUCT SKU SAMPLE: 636RF 14-2 UR4-8 2 SPECIFY OPTIONS Cover Mounted Manual Reset Switch for Fire/Emergency Release System On-Off Push Switch inside Power Supply Enclosure System On-Off Push Switch on Enclosure Cover TABLE 2: 12VDC STANDBY POWER 8 Ah Battery Qty 1 2 4 6 Amp Hours 8Ah 16Ah 32Ah 48Ah 2 3 6.5 15 24.7 2.5 2.3 5 11.5 19 3 1.8 4 9 15 3.5 1.5 2.4 7.5 12.5 4 1.3 2.8 6.5 11 5.9 2.2 5 8 6.8 1.7 4 6.6 14-2 7 Day Skip a Day Programmable Timer PC KL 220V/230V 6 ft. Power Cord Key Lock Cover 230VAC, 50/60Hz 3 SPECIFY CONTROL MODULES 12VR FB-4 PSM UR1 UR2-4 UR4-8 CR4 ACM-1 12VDC Regulated and Filtered Module Four 2 Amp fuse protected outputs Remote Monitoring Module Universal Door Controllers Two Station Door Controllers Four Station Door Controllers Control Relay - 4 Independent DPDT Relays Access Control Module TABLE 3: 24VDC STANDBY POWER 8 Ah Battery Qty 2 4 6 Amp Hours 8Ah 16Ah 24Ah 2 3 6.5 11 2.5 2.3 5 8.3 3 1.8 4 6.5 3.5 1.5 3.4 5.5 4 1.3 2.8 4.8 5.9 2.2 3.6 6.8 1.7 2.9 SDC power supplies equipped with batteries provide continuous operation of access controls, locking devices and peripheral components during a power failure. See Table 2 & 3 to determine battery requirements for standby power. PB-8 8 Amp Power Booster ACCESSORIES 248 PB-16 16 Amp Power Booster see page 257 for more info on control modules 636RF x 2-UR4-8 x 2 RB12V7 RB12V7 12VDC, 8 Amp Hour Battery SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM

621 Series 1 Amp Modular The 621 Series access control power supplies are designed to support access controls and electric locking devices. Equipped with two power limited outputs, the modular design enables versatility for installations with or without battery back-up or fire command center interface for emergency lock release. 621PJ FEATURES 12VDC or 24VDC Field Selectable 1 Amp Maximum, Filtered and Regulated 1 Power Limited Switched 1 Power Limited Auxiliary Two Control Inputs 1 Trigger Input, Normally Open (NO) 1 Supervised Emergency Release Input (Latching with Reset or Non-Latching) When latching emergency release is selected and the switched output is deactivated by emergency release or power loss, power is restored by manual means only Short Circuit and Thermal Overload Protection Automatically Switched to Battery Back-Up when AC Fails Board Equipped with AC Input, DC and Battery Status LED Indicator Enclosure Equipped with AC Input, DC and Battery Status LED Indicator MODELS 621PJ 621J 621P 621B Module and Cabinet with Door Mounted LED System Status Indicator, UL listed 24 VAC, 40 VA Plug-In Transformer Module, Cabinet with Door Mounted LED System Status Indicator Module, Retrofit Mounting Hardware includes Flush Mount Standoffs or Velcro, UL listed 24 VAC, 40 VA Plug-In Transformer Module Only, Retrofit Mounting Hardware includes Flush Mount Standoffs or Velcro 621P-UME Power supply module, with UL Listed plug-in transformer and Universal Module Enclosure (UME). 621P 621B SDC SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM 621P-UME FIELD 12 24 SELECTABLE YEAR 5 WARRANTY 249

SPECIFICATIONS 621P/621PJ Input 24VAC @ 40VA 150mA @ 12VDC 621B Input 115VAC 60Hz, 0.6 Amp Board 3.95 W x 3 H x 1.625 D Filtered and electronically regulated 1 Amp @ 12/24VDC (field selectable) Cabinet Enclosure UME Box Dimensions 7.25 W x 8.375 W x 3.625 D 5.625 H x 7.6875 W x 3.375 D Weight 4.2 lbs ACCESSORIES BACKUP BATTERIES SDC power supplies equipped with batteries provide continuous operation of access controls, locking devices and peripheral components during a power failure. RB12V4 12V/5Ah Battery, 621PJ Accommodates Two RB12V7 12V/8Ah Battery, 621PJ Accommodates One 250 SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM

SDC SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM 251