Save Thousands of Dollars Per Year!

Similar documents
Background. The function of wear rings. Wear Rings. Throat Bushing

In order to discuss powerplants in any depth, it is essential to understand the concepts of POWER and TORQUE.

DuPont Vespel CR-6100 APPLICATION AND INSTALLATION GUIDE FOR CENTRIFUGAL PUMP STATIONARY WEAR PARTS

You have probably noticed that there are several camps

SERVICE THE GORMAN-RUPP COMPANY P.O. Box 1217 MANSFIELD, OH FX

BLADEcontrol Greater output less risk

MOTOR SAMPLE PROBLEM #1 Low-Slip Drive Belts

Components of Hydronic Systems

Optimizing Airflow on Dust, Mist and Fume Collection Systems

Best Practice Variable Speed Pump Systems

Pump ED 101. Variable, Fixed Speed Control - - Float Switch Activation. Introduction

Automatic Recirculation Valves One Step Centrifugal Pump Minimum Flow Protection

Using the Phoenix MultiPlus to reduce operating cost of a generator

SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION

VARIABLE DISPLACEMENT OIL PUMP IMPROVES TRACKED VEHICLE TRANSMISSION EFFICIENCY

Performance means how fast will it go? How fast will it climb? How quickly it will take-off and land? How far it will go?

Submersible Turbine Pumps

AR No. # Low Pressure Irrigation

M SERIES. ASTM F998 Close-Coupled Centrifugal Pump

Measuring Pump Efficiency with Mike Eglitis

Baldor Basics: Motors

PWM APi 610 BB3 Multistage Pump

Chapter 7: DC Motors and Transmissions. 7.1: Basic Definitions and Concepts

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

Pumping Station. Marisa Handajani

The Power of Wear Rings

M Series. ASTM F 998 Marine Duty Pumps For Flows to 5,000 GPM

Goulds Lenntech. API th Edition / ISO nd Edition API BB2 Two-Stage, Between-Bearing, Radially Split

Pump ED 101. Power Factor (Part 2) - - Electricity Behaving Better

Efficient Pumping. Presented by: Mark Hemeyer Adam Mudge

BIG BAR SOFT SPRING SET UP SECRETS

Goulds 7200CB. API th Edition / ISO nd Edition API BB5 Barrel Multistage, Radially Split In-Line Diffuser Type

PWM API 610 BB3 Multistage Pump

IntelliPro VS Intelligent Variable Speed Pump By Sta-Rite. The single most valuable investment you can make in your pool

PREMIUM-EFFICIENT MOTORS

RS Multi-Stage, Ring Section Pumps

MOTORS, VOLTAGE, EFFICIENCY AND WIRING. A Deeper Understanding

Electronic Paint- Thickness Gauges What They Are, and Why You Need Them

LogSplitterPlans.Com

Using Variable Speed

Horsepower to Drive a Pump

Diesel Fuel Challenges and Nanofiber Media Filtration Solutions

PROCESS VFD SAVINGS CALCULATOR USER GUIDE CONTENTS ENERGY EFFICIENCY FOR BUSINESS CUSTOM INCENTIVES CUSTOM-TO-GO

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

The Practical Pumping Handbook

ITT. Goulds Pumps. AquaForce PRESSURE BOOSTING SIZING GUIDE. Engineered for life. Building and Municipal Applications.

How do we make city buses cleaner and more comfortable?

TORQUE CONVERTER. Section 2. Lesson Objectives. 6 TOYOTA Technical Training

PWM. API 610 BB3 Multistage Pump

Atlas Copco Air Compressors. ZB VSD range Variable speed direct drive centrifugal air compressors for low pressure applications EFFICIENCY MATTERS

Troubleshooting Guide for Limoss Systems

UNDERSTANDING ROD RATIOS

SHAFT ALIGNMENT FORWARD

CHASSIS DYNAMICS TABLE OF CONTENTS A. DRIVER / CREW CHIEF COMMUNICATION I. CREW CHIEF COMMUNICATION RESPONSIBILITIES

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection

High Speed, Low Weight Momentum/reaction Wheels. Larry Wilhide, Valley Forge Composite Tech, Inc. P.O. Box 344 Carlisle, PA (717)

Goulds API th Edition / ISO nd Edition API BB2 Single-Stage, Between-Bearing, Radially Split


A pump is a machine used to move liquid through a piping system and to raise the pressure of the liquid.

Energy Independence & Securities Act Frequently Asked Questions

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection

Welcome to the SEI presentation on the basics of electricity

Goulds 3640 ISO nd Edition/API th Edition API BB2 Two-Stage, Between-Bearing, Radially Split

Troubleshooting Pumps in a System

A Solar Enhanced, Zero- Waste Energy Management Solution How it Lowers Pump Jack Operating Costs

Light bulbs are almost burnt out

HOW BELT DRIVES IMPACT OVERHUNG LOAD

Exhaust Gas CO vs A/F Ratio

20th. SOLUTIONS for FLUID MOVEMENT, MEASUREMENT & CONTAINMENT. Do You Need a Booster Pump? Is Repeatability or Accuracy More Important?

Compressor Noise Control

Dynamics of Machines. Prof. Amitabha Ghosh. Department of Mechanical Engineering. Indian Institute of Technology, Kanpur. Module No.

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15

HIGH FUEL PRESSURE LINE

Vertical Pumps for the Oil & Gas Industry

Single Phase Induction Motors

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps

Pump Division MSP Vertical, In-line, Medium Speed Pump

Industry Standard for Reliability. Durability. Exclusive Features. Heavy-Duty Construction

Jeff Fehr, Senior Application Engineer. ACH550 Flux Optimization White Paper

Troubleshooting Guide for Okin Systems

A comparison between various pump systems for high flow rate tailings pipelines

APIFLO-M series Series

Interim report on noise in F2C, October 2010 Rob Metkemeijer

Basic Hydraulic Features. Basic Mechanical Features

BLOWERS EXHAUSTERS. Positive Displacement blowers (PD), as the name implies, compress CONTINENTAL INDUSTRIE

MOTOR SURVEY. Solutions for Industry

Actual CFM = VE Theoretical CFM

System One Pumps Selecting Centrifugal Pumps S1-201

13. The signal check of Vehicle Speed Sensor

General Catalog. A New Vision for Quality Pumps. General Catalog

SHOCK DYNAMOMETER: WHERE THE GRAPHS COME FROM

Industrial Air Motors

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

Canadian Manufacturer of Quality Weighing Systems

blackops: Blackmer Optimum Pump Solutions

Chapter 13: Application of Proportional Flow Control

Reassess your Pump Startup (S/U) and Shutdown (S/D) Procedures By Heinz P. Bloch For TECÉM tecem.com.br Oct,05,2013

Corbrasion resistant, high performance slurry pumps Designed for solids laden waste water to aggressive slurries

[P F/A] CHAPTER ,' II ' Hydraulic Actuators. cylinders. what cylinders consist of.

FAN ENGINEERING. Application Guide for Selecting AC Motors Capable of Overcoming Fan Inertia ( ) 2

Transcription:

Save Thousands of Dollars Per Year! Simsite Re-Engineered Double Suction Impeller Re-Engineer Your Impellers! Pump Company Since 1919 Simsite Structural Composite Pumps, Impellers, Rings and Parts Custom engineers pumps to meet your specific requirements.

It is an all too common problem You purchased a pump for one specific performance and when you put the pump in service in your plant or ship, the pump ends up operating at another point completely different from the original design point (best efficiency point BEP) of the pump. In addition to being very inefficient, when you operate the pump away from the original design point or best efficiency point (BEP) it causes a multitude of problems. These problems include excessive noise & vibration, shaft oscillation, cavitation, premature wear and failure of mechanical seals, bearings, rings, sleeves and impellers. In extreme cases, the shaft will break right behind the impeller from the excessive radial forces that occur when you operate a pump away from the original design point. Damage to these pump internals and poor reliability are a real and direct result of such operation. Fortunately, these problems can be easily resolved by re-engineering the impellers. Companies like SIMS PUMP Company in Hoboken, N.J. can redesign these impellers to operate at the new system design point. Now, the best efficiency point (BEP) will be the true operating point in the plant or ship system. Not only is the efficiency of the pump improved, but also the reliability of the complete pump is substantially improved. The effect of operating a pump away from the best efficiency point (BEP) has a detrimental effect on pump efficiency and wastes energy and money. The larger the pump, the more energy is wasted when a pump operates off the original design point; however, operating any pump away from the BEP wastes a tremendous amount of money since 85% of the total cost of owning a pump is the Operational Cost (Maintenance cost plus the cost of energy). BEP: B =Best E =Efficiency P =point

Lets take a look at the pump curve for a 1 x 1.5 6 pump: Let s consider a relatively small pump first. For example, if a customer is looking for a pump to produce 40 GPM at 140 feet of head, a 1x1.5-6 pump size (with approximately 6 impeller diameter) may be selected from hydraulic curves. The pump will work, but unfortunately will not be operating at its optimum design point or best efficiency point. As is evident from the hydraulic curve for this pump size, this pump will have 40% efficiency (yellow circle). However, the optimum design point or best efficiency point (red angle) is at 58% efficiency. The result is that the pump operates to the left of its BEP point for the impeller diameter required to achieve the desired head. As we have previously stated, issues of radial thrust, vibrations, and premature wear will definitely result. But, let us see what effect this will have on energy consumption. In the above hydraulic curve example, note that the horsepower line that passes near the operating point is approximately at 4 hp, which is roughly 3 kw. How much does it cost to operate this pump if running continuously, 365 days per year, at, say $0.10 per kilowatt-hour? 3 x 24 x 360 x 0.10 = $2,592 Now, what would it cost if the efficiency were somehow improved to the 48% efficiency that this pump would enjoy if the system operating point were to become the best efficiency or design point by redesigning the impeller? Obviously, if a pump runs more efficiently, it will take less power. In fact, the power (and thus cost) would be inversely proportional to efficiency: $2,592 x (40/48) = $2,160 The net ELECTRICAL savings would thus be $2,592 $2,160 = $432 per year, which is 17% less! However, when the pump is operating at 40GPM at 155 FT, instead of 100 GPM at 120 FT, the pump is operating in the danger zone, 60% away from BEP (Best efficiency Point). At this point, the pump is subject to high radial loading, which causes tremendous noise & vibration and excessive shaft oscillation. This leads to premature bearing, mechanical seal, and impeller failure. Old Technology - Metallic New Technology - SIMSITE

The new Re-engineered Simsite will be as follows: Performance Curve Using the chart in (figure 2), you can see that when the pump operates 60% away from design point (40 GPM at 155 FT. like in the example in the pump curve above) the pump failure rate has increase drastically, by 5.2 times! 833 days/163 days = 5.2 Times or 520% Higher Cost In other words, on the average, this pump will have to be overhauled 5 times more than if it operated at BEP. With an estimated overhaul price of $2500, the operational cost is approximately $13,000 more than it should be! Redesigning the Impeller and installing a new SIMSITE re-engineered impeller will save Electrical Costs and more importantly Operational Costs. Electrical Cost = $432 Savings per year per pump. Operational Cost = $13,000 Savings per pump Custom engineers pumps to meet your specific requirements.

Radial Thrust When a centrifugal pump operates to the left of the originally designed BEP (Best Efficiency Point) or to the right of the BEP, many bad things happen. First, radial thrust grows exponentially, resulting in significant shaft deflections and oscillations, which leads to premature mechanical seal failures, bearing failures, excessive bushing, ring, and sleeve wear and even shaft failure (breakage). Also, a hydraulic phenomenon called rotating stall sets-in, which is essentially a back-flow, leaving the impeller eye, and progresses backwards, which can result in violent piping vibrations, pressure pulsations, and premature wear of the components. The problem intensifies when a hydraulic parameter called suction specific speed (NSS) is high. Suction specific speed is the geometric relationship between the impeller eye diameter and the impeller outside diameter, and the NPSHR. It is an indirect indication of the impeller eye being too large, but also depends on several other factors, related to design, installation and application. There are certain engineering rules and principles related to minimum allowable flow - as function of pump energy, specific speed (NS), suction specific speed (NSS), and other factors, which when violated can cause trouble and problems. Operating Away from BEP Figure 2 Operating Away from Design Point The above chart represents an average failure mode based on information compiled by Sims Pump Company. P u m p Fa i l u r e i n D a y s 900 800 700 600 500 400 300 200 100 0 BEP 5 10 15 20 25 30 35 45 50 55 60 % Away from BEP 65 70 75 80 85 90 100 or Shut Off

Next, let s consider a somewhat larger pump. Say we have a 4x6-10 size that is operating in the plant system at 600 gpm and producing 100 feet of head: Again, the pump is off the efficiency peak. It operates at approximately 65%, whereas its peak efficiency at that diameter (10.25 ) should be 82% at the original specified performance of 1100 GPM at 88 Feet! Now, the energy dollars become more pronounced. Its power consumption is approximately 25 hp (19 KW), according to horsepower lines in the proximity of the operating point: 19 x 24 x 360 x 0.10 = $16,416 The electrical cost to operate the pump would be substantially less if efficiency were increased by re-designing the impeller to operate at the system requirements of 600 GPM at 100 Feet instead of 1100 GPM at 88 Feet. The efficiency at this new point would be increased to 78%: $16,416 x (65/78) = $13,680 The electrical savings would be: $16,416 $13,680 = $2,736 per year, about 16% in this case! This pump is operating in the system at 600 GPM at 100 feet instead of 1100 GPM at 88 Feet which is approximately 45% away from the original design point: (600/ 1100 = 55% -100 = 45% away from design point) From the chart above, we can determine that when this pump operates 45% away from the original design point (1100 GPM at 88 Ft. like in the example above) the pump failure rate has increased drastically, by 2.56 times! (833/325 = 2.56 Times or 256% Higher Cost) This pump will have to be overhauled 2.5 times more than if it operated at BEP. With an estimated overhaul price of $5500, the operational cost is approximately $13,750 more than it should be. Redesigning the Impeller and installing a new SIMSITE re-engineered impeller will save Electrical Costs and more importantly Operational Costs. Electrical Cost = $2736 Savings per year per pump. Operational Cost = $13,750 Savings per pump.

Let s next take even larger size, 8x10-17: Let s assume this pump operates at 2000 gpm (280 feet head), instead of a peak point of 4000 GPM at 240 feet of head. The efficiency at the actual operating point is only 70% instead of the potentially achievable 83% by this pump. The horsepower at the operating point is roughly 225 hp (168 KW), and the yearly energy bill is: 168 x 24 x 360 x 0.10 = $145,152 The electrical cost to operate the pump would be substantially less if efficiency were increased by re-designing the impeller to operate at the system requirements of 2000 GPM at 280 Feet instead of 4000 GPM at 240 Feet. The efficiency at this new point would be increased to 81%: $145,152 x (70/81) = $125,440 The electrical savings would be: $145,152 $125,152 = $20,000 per year, about 13.8 % in this case! This pump is operating in the system at 2000 GPM at 280 feet instead of 4000 GPM at 240 Feet which is approximately 45% away from the original design point: (2000/ 4000 = 50% -100 = 50% away from design point) From the chart above, we can determine that when this pump operates 50% away from the original design point (4000 GPM at 240 Ft. like in the example above) the pump failure rate has increased drastically, by 2.56 times! (833/300 = 2.56 Times or 256% Higher Cost) This pump will have to be overhauled 2.78 times more than if it operated at BEP. With an estimated overhaul price of $10,000, the operational cost is approximately $27,800 more than it should be. Redesigning the Impeller and installing a new SIMSITE re-engineered impeller will save Electrical Costs and more importantly Operational Costs. Electrical Cost = $20,000 Savings per year per pump. Operational Cost = $27,850 Savings per pump.

As you can see, the net savings depends on how far away from the Best Efficiency Point the pump operates. Unfortunately, this problem exists in all too many actual installations in the field. Many pumps, purchased and installed years ago, often no longer operate at the originally intended hydraulic conditions. As operating conditions change, the pump is simply throttled further and further away from the BEP. The result dollars literally burned up, -- not to mention other problems (high loads, shaft breakage, premature rotating life wear etc.). Obtaining a smaller pump is not a good answer. First of all, a smaller pump may still not (and usually does not) have the hydraulics sized to hit the operating point dead on. It may help somewhat, but is expensive and not as efficient. The user choice is limited only to the standard pump sizes available from the pump manufacturer s catalog, and even with a large number of sizes in the catalog, it is virtually impossible to cover each and every variation of the operating conditions. So, the user is forced to settle for the second best, but not the optimum. More importantly; however, is the issue of economics and feasibility of piping change, to accommodate a proposed pump downsizing. Piping changes alone can often cost more than a pump. A better solution is to install a new Simsite Impeller, custom-designed, engineered, and sized for your operating conditions. By doing that, the pump performance will essentially shift or slide to exactly where the Best Efficiency Point is, - and the net losses and radial loading become zero. Such approach is effective, and the investment is minimal, with a payback of less than a year, and often just a few months. Not only ANSI or single stage overhung-impeller pump designs can benefit from this approach. Split case and multistage pumps, are known to have benefited greatly with improved impeller hydraulics. When a metal impeller is replaced with structural engineered composite impeller such as - Simsite (85% lighter then metal), the combined effect of hydraulic fine-tuning with reduced weight (and thus load), can be dramatic. Rotor dynamic benefits of such an approach are obvious, and savings immediate. Other pump types, such as vertical multistage, river intake pumps, condenser, circulating, etc. can have similar issues, and could be likewise retrofitted with improved hydraulics designs, - quickly, efficiency, and economically. Remember, when you analyze the Total Cost of a Pump over the entire lifetime, you will find the following results: Only 4% of the Total Cost is the Initial Purchase Price, 85% of the Total Cost is the Operational Cost (Includes the Cost of Energy) and 11% of the Total Cost is Maintenance Cost. $ Example: A pump that costs $15,000. If you increase efficiency by 5% by installing a SIMSITE Impeller you will have saved $18,750 (More than the initial cost of the pump) If you suspect that your pump is not operating at the optimum conditions, - send us your hydraulic curve and indicate the desired operating condition. We will evaluate the potential energy savings, as a function of your operating conditions in relation to the actual pump BEP point. We will then evaluate the costs, and impact of rotor dynamics, and will provide our engineering recommendations. You may be surprised how much money you can save. Pump Valve Company, Inc. 1314 Park Ave, Hoboken, New Jersey 07030 USA Phone 1-800-746-7303 (201) 792-0600 Fax (201) 792-4803 www.simsite.com