PART MATERIAL FINISHING. Frame Carbon steel Painted or galvanised

Similar documents
products 22 º C Ventilation Air Conditioning Refrigeration Inside PROVIDED BY HEINEN & HOPMAN

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

products 22 º C Ventilation Air Conditioning Refrigeration Inside PROVIDED BY HEINEN & HOPMAN

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

DSA HIGH EFFICIENCY DROPLET SEPARATOR DROPLET SEPARATOR DSA. With heated vanes

HML - Airflow Unit for Large Volumes. HML Airflow Unit for Large Volumes. with Centralized Airflow Heating

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

NEW. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options.

HMR DUAL DUCT CABIN UNIT CABIN UNITS HMR. For passenger and crew cabins

DAMPERS LSS - R. N-6230 SYKKYLVEN, NORWAY TEL FAX

PK-I-Ex. Fire resistance class Circular: EI60S, EI90S, EI120S Square: EI90S, EI120S. Systemair Fire Dampers for Explosive Areas.

PART MATERIAL PART MATERIAL. Casing Hot galvanized steel / Option: stainless steel EN (AISI316L) Reheat coil EN 1.

7/S5 FIRE DAMPER FD40. v 2.9 (en)

Catef Marine-Fire. A-60 Marine Fire Damper. Includes new casing depths and thickness, Atex rated motor and visual indication options.

PTS - Single-Blade Damper. Halton PTS. Single-Blade Damper

Smoke damper EKO-SRB1

VAV TERMINAL BOXES TYPE: BA BT

KWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

HME SINGLE DUCT CABIN UNIT CABIN UNITS HME. Sound attenuator and balancing box

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

Fire/smoke damper EKO-SRBG1

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

Casing Hot galvanised steel / Option: stainless steel EN (AISI316L) Reheat coil EN (AISI 304)

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

NYBORG AS N-6230 SYKKYLVEN, NORWAY TEL FAX

Marine Fire and Gas Dampers

CAV controllers Type RN

Fire/smoke damper EKO-JBG2

OPTIVENT Housing HVSA, HVSL

PKIR3G, PKIS, PKIS3G and PKIS3GA

Fire & Gas Dampers. Fire & Gas Dampers are used in ventilation systems to prevent the spread of flame and/or smoke between divisions.

Bevent Rasch BSK Fire /04/2017

M A D E L. FOK-EIS-180 Fire dampers CE

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

RVP-R- VAV controller. In explosion-proof version

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

ESAS Smoke control damper

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Systemair Fire Dampers

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

Attachments. Explosion-proof actuators. For opening and closing multileaf dampers installed in potentially explosive atmospheres (ATEX) 09/2017 DE/en

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CFSD Series. Product Description

VOLUME CONTROL / REGULATING DAMPERS

BC 4.3. Gas Tight Dampers GTD-GB40-B-E LISTED

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

3/2-way Solenoid Valve for pneumatics

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

FSD60/MFSD60 Multi-blade Fire Damper

series FSD-FLD Fire and smoke dampers UL Approval

Regulation and shut-off damper SPB and SPC

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006

A-60 Marine Fire Damper

Motorized Fire Dampers

Fire/combustion gas damper EKO-JBG

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

Variable Air Volume Dampers

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Valve series KN-05 acc. to NAMUR, 3/2-way G1/4 780 Nl/min (0.792 Cv)

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

Particle Filter Box FKU

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

NSDZ. Swirl diffusers with adjustable air control blades

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Blade Features. AirShield Control and Shut Off Dampers. AirShield

For installation into ductwork

Short casing. Long casing (L version) Commercial premises

Combustion gas damper EKO-SRB

Slot diffusers, Round duct diffusers. IMP Klima

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Fire/combustion gas damper EKO-JBL

Combustion gas damper EKO-JB

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

NOVENCO FAN CATALOGUE

Specification. Introduction. A-60 Marine Fire Damper

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

Air distribution product

Systemair Fire Dampers

VARYCONTROL VAV Dual Duct Terminal Boxes

CRP. Commissioning damper, Ductwork Leakage Class 0

Transcription:

FDO A0(A0) Fire Damper FDO in picture with flanges (available as an option) Halton FDO fire dampers are type-approved class A0(A0) fire dampers for use in marine and offshore ventilation systems. The FDO can be installed in circular ducts. All fire dampers have a fusible link and they prevent the spread of fire within the ventilation ductwork. When the blade is in the open position, the device does not cause significant pressure loss, noise or flow disturbance. Fire dampers are set from outside and can be installed in any position. An open-closed indicator is visible on the outside of the damper. Type-approved by most recognized classification societies, class A0 - A0 fire damper when suitably insulated Fixed frame of painted, galvanized or stainless steel. Blades stainless or galvanized steel. Flanges available as an option. Blade contains seals (effective up to 20 ºC) Nominal fuse release temperature 50 ºC, 4 ºC or 100 ºC. Other temperatures available. Very low leakage Automatic electrical, pneumatic or spring operation system available Maximum duct pressure for damper construction 5000 Pa and maximum air velocity 15 m/s PART MATERIAL FINISHIN Frame Carbon steel Painted or galvanised Frame Stainless steel EN 1.401 (AISI04), EN 1.4404 (AISI1L), EN 1.442 (AISI1L) - Blades Steel alvanized Blades Stainless steel EN 1.401 (AISI04), EN 1.4404 (AISI1L), EN 1.442 (AISI1L) - Maintenance-free bearings Stainless steel EN 1.4404 (AISI1L) - Shafts Stainless steel EN 1.4404 (AISI1L) - FDO - A0(A0) Fire Damper 5

I I I FDO DIMENSIONS AND MATERIAL THICKNESS FDO fire dampers meet international standards for circular ducts (Ø100-500 mm). Sizes Ø100 and Ø125 are not available of stainless steel. Sizes starting from Ø10 can be manufactured with 1 mm division. Flanges and drilling available as an option and according to ISO 151 standards. Special flanges and drilling available on request. Frame material thickness according to SOLAS. ENERAL FDO DRAWIN (without flanges) I T Alt. Position of the actuator A C F FDO DRAWIN (with flanges) H T E ØD Alt. position of the actuator Damper Blade A B F C H FDO - A0(A0) Fire Damper

FDO Dimensions without flanges (standard) FDO Dimensions with flanges (as an option) FDO-EL FDO-PNR FDO-SP Damper Inside Outside Material Housing Blade Elodrive CSQP Belimo Air Torque Air Torque Spring size dimensions dimensions thickness Lenght /Schischek BF AT50 AT100 Ø A C T F H I H I H I H I H I 100 100, 10, 200-150 200 115 200 145 215 15 215 150 115 125 125 1 4 200-150 200 115 200 145 215 15 215 150 115 10 10 1 200-150 200 115 200 145 215 15 215 150 115 200 200 20 20-150 200 115 200 145 215 15 215 150 115 250 250 25 20-150 200 115 200 145 215 15 215 150 115 15 15 21 20-150 200 115 200 145 215 15 215 150 115 400 400 40 4 20 4 150 200 115 200 145 215 15 215 150 115 500 500 50 4 20 9 150 200 115 200 145 215 15 215 150 115 FDO-EL FDO-PNR FDO-SP Damper Inside Bolt Outside Material Bolt Bolt holes Housing Blade Elodrive CSQP/ Belimo Air Torque Spring size dimensions circle dimensions thickness holes Qty Lenght Schischek BF AT 50 Ø A B C T D E F H I H I H I H I 100 100, 120 200,,5 4 20-150 200 115 200 15 105 150 115 125 125 150 225 4,5 4 20-150 200 115 200 15 105 150 115 10 10 15 20,5 4 20-150 200 115 200 15 105 150 115 200 200 225 00,5 4 2-150 200 115 200 15 105 150 115 250 250 20 50 12 4 2-150 200 115 200 15 105 150 115 15 15 55 415 12 2-150 200 115 200 15 105 150 115 400 400 450 500 12 2 40 150 200 115 200 15 105 150 115 500 500 50 00 12 12 2 90 150 200 115 200 15 105 150 115 VM09Y2015/Halton Marine reserves the right to alter products without notice. WEIHTS OF STANDARD HALTON MARINE FDO DAMPERS (K) without an actuator FDO weight without flanges FDO weight with flanges Size ØD (mm) K Size ØD (mm) K 100 4 125 5 10 4,5 200,5 250 9 15 12 400 1 500 22,5 100 5 125,5 10 200 9,5 250 11 15 14,5 400 1 500 22,5 Weights stated above do not include flanges or any actuator. Examples of actuator weights: FDO-EL CSQP +,5 kg, BF20 +,2 kg, BLF20 +1, kg, ExMax or RedMax or InMax +,5 kg, FDO-PNR AT100 (AISI) +,2 kg, AT50 (AISI) + kg, FDO-SP +1 kg. FDO - A0(A0) Fire Damper

FDO PRODUCT OPTIONS Halton FDO is available with following actuators: FDO-EL: Electrical spring return motor; standard actuators being 24 V or 20 V or 120 V. The motor contains built-in open-closed limit switches. Separate junction box included in the EL-model. A wide range of eex-proof actuators available, including a one second closing time function as an option. FDO-PNR: Pneumatic rotating actuator FDO-SP: Manual spring-actuated damper with fusible link DOT: manual override function available for PNR models. A wide range of accessories available. OPERATION PRINCIPLE In the event of a temperature rise in ductwork: FDO-EL: fusible link releases and cuts off operating voltage to the spring return motor, allowing the spring to close the damper blades. The fire damper opens automatically when the fuse has been changed and the operating voltage to the motor is re-established. FDO-PNR: fusible link releases and cuts off operating pressure to the spring return actuator, allowing springs to close the damper blades. The fire damper opens automatically when the fuse has been changed and the pneumatic air supply is re-established. FDO-SP: fusible link releases allowing the spring to close the damper blades. When the fuse has been changed, the fire damper must be reset into open position manually. FDO LEAKAE CLASS ACCORDIN TO STANDARD EN151 Size ØD (mm) Closed blade leakage Casing leakage 100 2 C 125 2 C 10 C 200 C 250 C 15 C 400 C 500 C FDO-EL WIRIN DIARAM with Elodrive CSQP FDO-EL WIRIN DIARAM with Belimo actuator POWER SUPPLY 120/20 V AC L N POWER SUPPLY 120 V AC DAMPER DAMPER CLOSED OPEN 4 L 1 14 N 4 5 4 5 2 1 9 10 11 9 10 11 (+) 1 14 (-) 4 4 5 9 10 11 4 5 9 10 11 2 1 S1 S2 S S4 S5 S 2 x 0,5 mm² x 0,5 mm² SIHF 2 x 0,5 mm² 14 1 FUSIBLE LINK x 0,5 mm² N T - L1 ~ + ELODRIVE CSQP-15A1E 15A2E 10A1E 10A2E 05A2E 05A2E IP SIHF 2 x 0,5 mm² 14 1 FUSIBLE LINK 4 C M S1 S2 S S4 S5 S 5 0 WHEN DAMPER IS NOT ENERIZED CONTACTS S1-S2, S4-S5 ARE CLOSED BELIMO BF24 BF20 BF120 BLF24 BLF20 IP 54 FDO - A0(A0) Fire Damper

FDO-EL WIRIN DIARAM with ExMax or RedMax actuator PE -EARTHIN RAIL x 0,5 mm² PE POWER SUPPLY 24-20V AC/DC L/+ N/- PE (PE) 4 4 5 9 10 11 12 1 14 15 4 5 9 10 11 12 1 14 15 BK Y BN 2 5 1 4 4 5 BK Y BN FUSIBLE LINK DAMPER DAMPER CLOSED OPEN 4 x 0,5 mm² x 0,5 mm² PE 2 5 1 4 4 5 HEATER 5 5 WHEN DAMPER IS NOT ENERIZED CONTACTS S1-S2, S4-S ARE CLOSED ExMax-15-SF RedMax-15-SF IP FDO-EL WIRIN DIARAM with InMax actuator SIHF 2 x 0,5 mm² 14 1 FUSIBLE LINK 50/4/100 C DAMPER DAMPER CLOSED OPEN 4 PE 4 PE 4 5 9 10 11 12 1 14 PE 4 5 9 10 11 12 1 14 PE 24-20 V AC/DC PE 1 14 ~ ~ 2 5 1 4 4 5 x 0,5 mm² x 0,5 mm² PE 2 5 1 4 4 HEATER 5 5 5 WHEN DAMPER IS NOT ENERIZED CONTACTS S1-S2, S4-S ARE CLOSED InMax-15-SF IP VM09Y2015/Halton Marine reserves the right to alter products without notice. FDO-PNR PNEUMATIC DIARAM ON BOX SE A (2 C) 4/100 C 0 4 OPTION: LIMIT SWITCHES SPRIN RETURN ACTUATOR SPEED CONTROLLER QUICK EXHAUST VALVES PIPELINES:POLYAMIDE FUSIBLE LINK VALVE PORT/2 WAY OPTION: MANUAL VALVE PORT/2 WAY OPTION: SOLENOID VALVE PORT/2 WAY PRESSURE REULATOR PNEU. INLET (5 - BAR) FOR A PLASTIC TUBE Ø MM CLOSED 21 1 1 OPEN 22 14 22 14 12 11 2 4 9 1 10 5 24/220 V 1. SPRIN RETURN VALVE 2. QUICK EXHAUST VALVE. SILENCER 4. FUSIBLE LINK VALVE 5. OPTION: SOLENOID VALVE. MALE CONNECTOR. DOUBLE NIPPLE. PLASTIC TUBE. OPTION: STAINLESS STEEL 9. OPTION: OPEN / CLOSED SWITCHES 10. OPTION: MANUAL VALVE 11. PRESSURE REULATOR 12. SPEED CONTROLLER 24...20 VAC/DC (+)(-) PE ~ ~ FDO - A0(A0) Fire Damper CLOSED AND OPENED INFORMATION OUT JUNCTION BOX ION BOX 9

FDO - A0(A0) Fire Damper 10