RU Series AFE Unit & Regeneration Unit

Similar documents
Application Case. Issued by Solution Center Date May, 2013 Pages 5

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Common Bus and Line Regeneration

Elevator operation energy consumption problem

SDC,Inc. SCR-Regenerative Ac Drive

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Inverter System Accessories

HYBRID STEPPER MOTOR DRIVER. Model: 2LD880H. MotionKing (China) Motor Industry Co., Ltd. 1. Introduction, Features and Applications

Product Application. Application: Delta C2000 Series AC Motor Drive and AFE2000 Active Front-End Unit for Bridge Crane (Overhead Travelling Crane)

Frequency Converters.

ADV200 & AFE200 Products Overview

SINAMICS GM150 IGCT version

ABB machinery drives. Application guide Common DC system for ACS380 drives

Technical Explanation for Inverters

OFF GRID SOLAR INVERTER

MaxPak Plus Analog DC V S Drive

Protection of Power Electronic Multi Converter Systems in AC and DC Applications

Power Factor Improvement

:

The cement and minerals industry

Unidrive M700 Class leading performance with onboard real-time Ethernet

Energy recovery during the braking operation

Power Electronics

American Traction Systems

Introduction to Variable Speed Drives. Pekik Argo Dahono Electrical Energy Conversion Research Laboratory. Institute of Technology Bandung

WG5Kxxx Modular DC-converter system

SINEE s products and solutions (VFD)

TECHNICAL DATA SHEET KVA UPS Systemss

Single phase to Three phase converter

Your choice for wall and panel mounted AC drives. Emotron FDU & Emotron VFX IP20/21 up to 160 kw

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

From Discrete IGBT Modules to Power Stacks

USER S MANUAL USER S MANUAL

Achieves a high-efficiency conversion of 94% despite being isolated type through digital control

Hitachi America, Ltd.

Course Name: POWER ELECTRONICS Course Code: EE603 Credit: 4

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

Power Conversion System The Best Technology for your photovoltaic and storage system

Application of ALPHA6000 Inverter in the Cement Industry

Oil Lubricating Device

FEATURES 特性 APPLICATIONS 用途 PART NUMBERING SYSTEM 品名系统 STRUCTURAL DRAWING 结构图. containing ferrite powder 1. 表面贴装, 小型 超薄电感器, 大功率, 高饱和, 低电阻之特性.

The Circuit and Control Technology in the Power Conditioner and Converter for Wind Turbine Systems

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

U1000 INDUSTRIAL MATRIX DRIVE

The MICROMASTER has four modes of operation:

Small size High power

Huawei Network Energy, Powering the Future. Huawei UPS Solutions HUAWEI TECHNOLOGIES CO., LTD.

DYNAMO & ALTERNATOR - B FIELD LOGIC PROBE.

Product brochure. Medium voltage AC drive ACS 1000, ACS 1000i 315 kw 5 MW, kv

Lecture 1. Introduction to Power Electronics

Regenerative Utility Simulator for Grid-Tied Inverters

Yueqing Sandi Electric Co., Ltd is an international PV enterprise which is located in the "capital

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

AC DRIVES. AC Drives. The word "drive" is used loosely in the industry. It seems that people involved

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

Lithium Power Cabinets

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

690-V Inverters Equipped with SiC Hybrid Module FRENIC-VG Stack Series

TDBU Series Dynamic brake unit user manual

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Combination control for photovoltaic-battery-diesel hybrid micro grid system

SMS PRODUCT CATALOGUE

D Series: UPS UPTO - 300KVA - Three / Three Phase

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Power Conditioning of Microgrids and Co-Generation Systems

ELECTRIC DRIVES N.K. DE P.K. SEN

Variable Speed Drives Controlling Centrifugal Pumps Energy Savings

Shenzhen Sine Electric Co., Ltd.

POWER ELECTRONICS & DRIVES

GREE Photovoltaic DC Inverter Centrifugal Chiller

An Engineering Guide to. Soft Starters

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

M7612 PIR CONTROLLER GENERAL DESCRIPTION 功能叙述 FEATURES 产品特长 APPLICATIONS 产品应用 PIN ASSIGNMENT M7612P

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Models: PMG A and PMG P

4100C BOSS AC Shovel Drive System Overview. WMEA Edmonton - June 2008

EFFEKTA Power Supplies

PowerFlex 6000 Medium Voltage AC Drives

Sustainable Energy Mod.1: Fuel Cells & Distributed Generation Systems

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

EE 842: ELECTRIC POWER SYSTEM IV (3-1-0) Full marks: Theory 100 Sessional=75

Power Electronics & Drives [Simulink, Hardware-Open & Closed Loop]

The Master of IEEE Projects. LeMenizInfotech. 36, 100 Feet Road, Natesan Nagar, Near Indira Gandhi Statue, Pondicherry

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

ELECTRIC MACHINES EUROLAB 0.3 kw

Study Solution of Induction Motor Dynamic Braking

ACS 1000, ACS 1000i. Medium voltage AC drives for control of induction motors from kw

... RTU Technical Manual. Packaged Air Conditioning Unit...

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Three Phase UPS Systems Range: 10 to 500kVA

Research Challenges in Microgrid Technologies

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

User Manual. Model P403. High Performance Microstepping Driver

3ph UPS NS3000 series kVA

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications

Liebert. FP 50Z kva

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

Transcription:

因技术 得品质 以服务 RU Series AFE Unit & Regeneration Unit JiaWei Yang 08/2014

Contents 1 2 Product Introduction Part of the product 3 4 Applications of product Product Specifications

1. Product Introduction-Basic Concept What is Regeneration Unit? Regeneration Unit, or The Energy Feedback Unit, the full name for special energy feedback unit of frequency converter, is a kind of special inverter braking unit, is mainly used for large inertia frequency speed regulation system, help renewable electricity back to the grid produced in the process of the motor reducing the speed,help system achieve rapid braking.

1. Product Introduction-Basic Concept Classification: 1.Parallel energy feedback refers to feedback device and VVVF used in parallel. 2.Tandem energy feedback refers to feedback device and VVVF used in tandem, usually say "active front end rectifier and inverter"afe(active Front End)

1. Product Introduction- Our product RU Series AFE Unit & Regeneration Unit arise at the historic moment. RU600 was developed and launched in 2013, high-performance, active energy feedback unit It can be used in conjunction with the inverter,can replace the traditional braking resistors, reducing heat generation.the effect of energy-saving is obvious. While minimizing the input side harmonics, Reduce the pollution to the grid in the use process of inverter. With a converter to achieve fourquadrant operation.

1. Product Introduction- Our product Energy flow diagram Energy consumption braking mode Energy feedback mode Power supply VVVF Motor Power supply VVVF Motor Energy resistance Regeneration unit RU630 AFE Mode Power supply AFE VVVF Motor Motor driven RU600 Braking

1. Product Introduction- Our product A Structure Design B Easy to use C Guaranteed by design Galvanized chassis effective safety ground Wall-mounted installation program supports and floor Independent duct design Efficient design parameters Pluggable terminal block design. Simplify loading and unloading. Design of new features and ease of keyboard IPD complete development process Optimized thermal design model Power chip thermal assessment program A common platform of design and manufacture to ensure the quality.

Contents 1 2 Product Introduction Part of the product 3 4 Applications of product Product Specifications

2.Part of the product- The whole system diagram Drive and protection circuits Functional circuits and optical isolation DC-Bus

2.Part of the product -RU600 Wiring Diagram The three 三相 phase 电源 grid MCCB MC R/L1 S/L2 T/L3 RU600 + - 变频器 M 多 功 Multi-function 能 terminals 输 Input 入 Others: Standard RS485 端 communication 子 terminals, Modbus protocol support RUN STOP ET RES External expansion card, Multi-machine communication interconnection 通讯端口 Communi cation port X1 X2 X3 X4 X5 X6 GND A+ A- RA RB RC Y1 GND PE ground 接地 继电器输出触点 AC250V 10mA 以上 3A 以下 DC30V 10mA 以上 1A 以下多功能开路集电极输出 0V~24V/0mA~200mA 接地 ground PE

Contents 1 2 Product introduction Part of the product 3 4 Applications of product Product specifications

3. Applications of product - Typical applications Large cargo lifting equipment when removing the cargo,installation RU600 / RU630 can replace conventional braking resistor. Elevator light load upward, overload downward,motor in the state of renewable energy, installation RU600 / RU630 can make Energy back to the grid, to save energy.

3. Applications of product - Typical applications Energy feedback unit used in high inertia loads such as: fan, cement pipe, balancing machines, centrifuges grinder, etc. Energy feedback unit for applications requiring quick stop occasions, such as rolling mills, large planer, machine tools, presses, etc.

3.Applications of product - Other applications Regeneration unit as inverter device for wind power, the electricity coming from wind power generator can be sent back to the utility grid by means of regeneration unit. Regeneration unit used in photovoltaic power generation, the electricity coming from photovoltaic panels can be sent back to the utility grid by means of regeneration unit. Energy feedback unit used in UPS power supply, EPS power supply, AFE units used in applications where a stable DC voltage is needed, energy feedback unit is used as a power inverter for local load electricity generation.

3.Applications of product applications in spot Regeneration unit RU630 was used in the Construction Machinery Company In Guangxi. R&D Laboratories and production plants in A4 RU600 was used in Motor Test System in our R&D laboratories and product plants.

3. Applications of product - Operating Mode Wiring a CH1: Inverter input current waveform when RU600 is not used CH3: AFE input current waveform Automatic switching of the rectifier / feedback operation mode based on the bus voltage change, the current flow in both directions, the bus voltage is held constant, the power factor is close to 1. And can be limited to a single direction rectifier mode, provided for electrical constraints for irreversible system, such as diesel generators.

3. Applications of product - Operating Mode Wiring b : RU630-11kW CH1: DC-bus voltage. CH3: feedback current When braking the motor, when the bus voltage exceeds the set voltage, the capacitor energy back to the grid. Improve the use of energy-efficient to achieve energy saving,compared with braking resistor.

3. Applications of product - Operating Mode RU60 0 Mode Wiring Current control 1 Four quadrant rectifier Wiring a Controllable bidirectional flow 2 Single rectifier mode Wiring a Controlled rectifier 3 Single feedback mode Wiring b Network side flow RU630 Mode Wiring Current control 1 Single feedback mode Wiring b Network side flow Well,let s watch a video.

Contents 1 2 Product Introduction Part of the product 3 4 Applications of product Specifications and attention

4.Specifications and attention-naming Rules Rated input voltage Type Power(kW) Rated output current(a) Three-phase AC-380V RU600-030-3 30 60

4.Specifications and attention- Shape and Size Product model Shape Size/mm Installation size/mm Remarks W H D W1 H1 D1 RU600-030-3 316 595 249 240 573 8 RU630-011-3 270 480 150 150 482 9 W =316 W1=240 D1=249 H =595 H1=573 4-M6 12 RU600 4-M8 14 RU630

4.Specifications and attention- Selection guide When using the four-quadrant mode rectifier mode, in accordance with the following selection table : Inverter power(kw) 7.5 9 11 15 22 30 RU power(kw) 11 30 Dedicated to energy feedback mode (instead of braking resistor), you can press the selection table: Inverter power(kw) 15 18.5 22 30 37 45 RU power(kw) 11 30 Other products are in development.

4.Specifications and attention-technical Feature Low harmonic value :Advanced PWM technology, harmonic value of the current less than 5%. Power Factor: Real-time monitoring of the grid, to ensure that the power factor> 0.95(usually 0.98). Group control features: supports two sets of parallel, system expansion, networking group control Dynamic performance: solve fast transient braking problems, improve system braking performance Personalized solution:solve lift type equipment overload problem Automatic current limiting: Automatically switched according to the external environment and usage Perfect solution in parallel circulation:reduce energy consumption, improve performance Perfect voltage loop control strategy:to ensure the DC-bus voltage of frequency converter accurate and stable

4.Specifications and attention-attention Check program: First power off Then check carefully First outside and then inside First control and then power part Three-phase grid Inductance IGBT Model Soft-Drive capacitor Frequency Convert Fuse Switching Power Run time, to ensure Running lights are lit The control logic is normal Operating current and the detected current is consistent Input and Output terminals are normal The red dashed box for RU600

4.Specifications and attention-attention In my experiment, encountered some problems, and share 5 tips with you: Tip1. It is different with the inverter, RU600 require real-time monitoring of the grid voltage.if it shows LP,after power on,firstly check the grid voltage detection line wiring is properly connected to the grid. Tip2. When using an external inductor,grid detection wire needs to be connected to the grid side. Tip3. Energy feedback unit and inverter applications in parallel mode, need to use Commonmode Choke in series with the bus, or will cause circulation, affecting the normal use. Tip4. Power normal, keyboard display properly on RU600, but the bus voltage and bus voltage of the inverter are inconsistent, to confirm the internal fuse is damaged or not. Tip5. It is different from the inverter, losing uncontrolled rectifier bridge, increasing the grid voltage detection circuit, so we can handle the rest of the abnormal as the inverter.

Figures

Thanks!