SWITCH DISCONNECTORS PLANET -SWITCH.

Similar documents
Products and solutions for photovoltaic applications

Panel-mounting components

Switch disconnectors and fuse switch disconnectors

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

Polymas Watertight PK Enclosures Product Drawings Last Updated 6/18/2008

CS COMPACT ENCLOSURE. CABINETS. method for lifting uses the same eyebolts as ATB8 cabinets. optional 180 hinges available

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

ETA quality, promptly

Bulletin 140U R-Frame Molded Case Circuit Breakers

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

ATB8 MONOBLOC CABINET

Bulletin 194L 194E 194E

(p. 47) (p. 155) (p. 155)


cabinets and equipment Atlantic, Atlantic stainless steel, Marina

ECO/PCI Compact Enclosures Product Drawings Last Updated 6/19/2008

Page 2-4 Page 2-8. Page Page 2-13

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

Switches Unlimited Phone: * Fax:

For Info: Phone: Fax:

Fuse holders and fuses

Fiberglass Watertight Modular Flange Product Drawings Last Updated 1/6/2006

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

PLIO -GRAINS cable ties

PowerLine OS Switch Fuses A, 690V

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Din rail power supplies

Limit, micro and foot switches K series

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES

Description Order Code Order Code Order Code Order Code Order Code

Section 8. Operating Mechanisms and Disconnect Switches Operating Mechanisms and Disconnect Switches 8-2. Table of Contents

7E x0. Nominal current 5 A (32 A Maximum) 1-phase 230 V AC 17.5 mm wide

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

K50H004UP cam changeover switch - 4-pole A - screw mounting

SIRCO M and MV Universal load break switches from 16 to 160 A

An innovative technology

MCBs and RCDs LR TM 6000

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

Cylindrical fuse-link

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

BOXES SOLUTIONS. BOXES

Selection Guide Motor Control Device Solutions

Contents. Volume 5 Motor Control and Protection CA E December

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference

Heavy Duty. this page Page 4-16 Page 4-19 Page Mounting Clamp. 8 ArmorBlock MaXum. 9 Standard Cordsets. 10 DeviceNet Photoelectric

K30H001YP cam star-delta switch - 3-pole A - screw mounting

DC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

UL/CSA Non-fused Disconnect Switches

Modulostar US10 Modular fuse-holders

Solar Installer Range. Bright solutions

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

Page 2-4 Page 2-8. Page Page 2-12

What you need to know. Â Conformity to standards

Modular contactors and relays

Switch Disconnectors

Proximity Sensors and Limit Switches

Thermal Overload Relays

SD Series Non-Fused Load Switches

SERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring:

UltraSafe US22 Modular fuse-holders

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

Load Break Disconnect Switches FSLBS

25A 25A 32A 40A 40A 63A 63A 80A

MS General Information Extended Product Type: MS

NB1 Miniature Circuit Breaker

XACA871 pendant control station XAC-A - 8 pushbuttons

Size for Size Best Value in the Industry

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

K63F003UP cam changeover switch - 3-pole A - screw mounting

K50F003UP cam changeover switch - 3-pole A - screw mounting

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

DisconnectSwitches16Ato250A Enclosed,DoorMountandPanelMountDisconnects 3,4,and6PoleModels 3PadlockableHandle Styles Add-onPowerContacts Auxiliary

RESIDENTIAL BUILDINGS & HOTEL EQUIPMENT

Section Contents. Disconnect Switches

Just the right switch for your application

Vistop TM isolating switches 63 to 160A

XACA871 pendant control station XAC-A - 8 pushbuttons

Ø64 LOAD BREAK SWITCHES Ø4.5 Ø12 Ø48. Panel Door

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

IEC Low Voltage Products Module 4

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Series L9 UL489 Miniature Circuit Breakers

UL Enclosed Disconnect Switches (Fused and Non-Fused)

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

Transcription:

SWITCH DISCONNECTORS 6A to 600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 50A. PLANET -SWITCH SEC. PAGE 6A to 5A Three-pole switch disconnectors................................... - 4 Fourth pole add on............................................... - 4 For photovoltaic applications...................................... - 5 Fourth pole for switch disconnectors for photovoltaic applications....... - 5 Add-on blocks and accessories.................................... - 6 Three-pole switch disconnectors in housing......................... - 0 Empty enclosures............................................... - 0 9 / 0 _

- Overview 9 / 0 electric 6A to 5A DIRECT OPERATING HANDLE AND DOOR MOUNT VERSION VERSION IN HOUSING DOOR COUPLING VERSION 36mm width 70mm width 36mm width 70mm width 00mm width 0mm width ACA 6A 5A 3A 40A 63A 80A 00A 5A 6A 5A 3A 40A 63A 80A 00A 5A 6A 5A 3A 40A 63A 80A 00A 5A Three pole 4th pole - simultaneous closing 4th pole - early-make closing Three-pole for photovoltaic applications Fuse holder Handle recessed selector, screw fixing protruding selector, screw fixing protruding selector, ring fixing protruding selector with release, defeatable, ring fixing protruding selector low-profile, ring fixing pistol grip with release, defeatable, screw fixing Mechanical 6-8 pole coupling system Mechanical interlock for line switching 50A to 600A DIRECT OPERATING AND DOOR COUPLING VERSION ACA 50A 5A 60A 00A 50A 35A 400A 500A 630A 800A 000A 50A 600A Three and four pole Three and four pole with NFC fuse holder Three and four pole with NH fuse holder Three and four pole with BS fuse holder Four-pole for photovoltaic applications Changeover switches 60A to 600A DIRECT OPERATING AND DOOR COUPLING VERSION ACA 60A 00A 50A 35A 400A 500A 630A 800A 000A 50A 600A Three and four pole Motorised control unit REV. 0_

electric 9 / 0 Overview -3 6A to 5A COMPACT SIZE The three-pole 6A to 40A switch disconnectors, are made up of a single unit body, merely 36mm wide, while the 63A to 5A ratings, of another body size of only 70mm wide. VERSIONS are standard supplied with direct operating handle and for door mount. A shaft extension and rotating handle can be ordered separately to transform the direct operating control into a door coupling type. IP65 PADLOCKABLE HANDLES Wide range of selector or pistol grip handles, with screw or ring fixing. All handles are equipped with built-in padlockable mechanism. The selector handle GAX63... is snapped on to the door-mount switch disconnectors in6a to 40A ratings, with no need of tools. HANDLE ADAPABILITY The extensive number of fixing holes in the front handle plate can replace switch disconnectors, normally found out in the field, without having to drill other holes. VERSION FOR PHOTOVOLTAIC APPLICATIONS The GA...D type switch disconnectors are suitable for both small domestic installations as well as those with a large number of solar cells. Use up to 000V in DCB category. SIDE MOUNT ADD-ON FOURTH POLE Simultaneous or early-make contact operation of the fourth pole with respect to the switch disconnector poles. ADD-ON AUXILIARY CONTACTS One only add-on block suitable for all the 8 ratings of switch disconnectors, having simultaneuous operation with the switch poles. There are versions with an early-break NO contact. REDUCED HANDLE THICKNESS GAX6 and GAX 6 B handles are only 3mm thick. 3mm MAXIMUM COMBINATIONS Mounting up to 4 auxiliary contacts or fourth pole and 3 auxiliary contacts ( blocks always on the right and on the left side) of each switch disconnector. The earth and neutral terminals and fuse holder also can be added. ADD-ON BLOCK MOUNTING Mounting and removal of the fourth pole and add-on blocks are simple and quick operations with no need of tools. 6 AND 8 POLE VERSION A mechanical coupling system is available for the 6A to 5A switch disconnectors with direct operating handle to provide 6/8 pole disconnectors along with a mechanical interlock mechanism for the line changeover function (I - 0 - II). FUSE HOLDERS A three-pole fuse holder can be added to 6A to 3A switch disconnectors, with direct operating handle, to provide a single compact unit. Access to the fuse can be made only when the disconnector is in OFF position. CERTIFICATIONS All GA series switch disconnectors are certified by GOST and by UL for Canada and USA. The 6A to 40A types are certified according to UL508/CSA. n 4 while the 63A to 5A types to UL98/CSA. n 4 standards. The KEMA certification is pending completion. 9mm DEFEATABLE UL508A HANDLE VERSION In compliance with UL508A standards, which require internal panel inspection by authorised personnel with power applied, selector and lever handles are available with defeatable feature of the door coupling when the switch disconnector is closed, i.e. in ON position. SWITCH STATUS INDICATION The switch open or closed state is clearly and unequivocally seen at a distance thanks to the simple and modern design of the handle. DIN RAIL FIXING The fixing on and removal of the switch disconnector from the 35mm (IEC/EN 6075) DIN rail are done, by only pressing downwards, without tools. PAD INSERT FOR NO DIN RAIL SLIDING A rubber pad insert prevents the sliding of switch disconnectors on the DIN rail even when out of tolerance or mounted vertically. TERMINAL ADAPTABILITY Terminals are suitable to accept any type of cable: flexible, rigid, AWG wire. The terminals can withstand high tightening torques. HIGH CAPABILITY IN AC3 The rated currents Ie in AC3 at 690VAC are the highest of the category. MODULARITY The switch disconnectors can be mounted in modular panels. REV. 0_

-4 6A to 5A switch disconnectors Three pole - Fourth pole add on 9 / 0 electric Three-pole switch disconnectors GA06 A- GA040 A GA06 C- GA040 C GA063 A- GA5 A GA063 C- GA5 C Order code Conventional Rated Qty Wt free air operational per thermal current Ie current Ith ACA ACA ( 690V) ( 690V) AC3A ( 45V) [A] [A] n [kg] Direct operating version, complete with black handle. For door-coupling version, separately order the handle and shaft extension; refer to page -8 and -9. GA06 A 6 6 0.35 GA05 A 5 5 0.35 GA03 A 3 3 0.35 GA040 A 40 40 0.35 GA063 A 63 63 0.365 GA080 A 80 80 0.365 GA00 A 00 00 0.365 GA5 A 5 5 0.365 Door-mount version, complete with shaft; separately order the handle, refer to page -8. GA06 C 6 6 0.35 GA05 C 5 5 0.35 GA03 C 3 3 0.35 GA040 C 40 40 0.35 GA063 C 63 63 0.365 GA080 C 80 80 0.365 GA00 C 00 00 0.365 GA5 C 5 5 0.365 General characteristics 6A to 5A ratings Available versions: direct operating door mount door coupling version. Use switch disconnector with direct operating handle and separately order the handle and shaft extension for this version. See page -8 and -9 Compact and modular size Screw or 35mm DIN (IEC/EN 6075) rail fixing Padlockable in 0 position with no extra accessory. Operational characteristics Rated insulation voltage Ui: 000V Rated impulse withstand Uimp: 8kV Electrical life in ACA: 00,000 cycles for GA06-GA040 30,000 cycles for GA063-GA5 Mechanical life: 00,000 cycles for GA06-GA040 30,000 cycles for GA063-GA5. Certifications obtained: GOST; culus (to UL508/CSA. n 4 for GA06... GA040... and corresponding fourth pole; to UL98/CSA C. n 4 for GA063... GA5... and corresponding fourth pole). Certifications pending: KEMA for switch disconnectors only. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-3, UL508, UL98, CSA C.. Fourth pole add on GAX4...A GAX4...A GAX4...C GAX4...C Order code Conventional Rated Qty Wt free air operational per thermal current Ie current Ith ACA ACA ( 690V) ( 690V) AC3A ( 45V) [A] [A] n [kg] Simultaneous closing operation as switch poles. For GA...A versions. GAX4 040A❶ 40 40 0.040 GAX4 063A 63 63 0.0 GAX4 080A 80 80 0.0 GAX4 00A 00 00 0.0 GAX4 5A 5 5 0.0 For GA...C versions. GAX4 040C❷ 40 40 0.040 GAX4 063C 63 63 0.0 GAX4 080C 80 80 0.0 GAX4 00C 00 00 0.0 GAX4 5C 5 5 0.0 Early-make closing operation with respect to switch poles. For GA...A versions. GAX4 040A❶ 40 40 0.040 GAX4 5A❸ 5 5 0.0 For GA...C versions. GAX4 040C❷ 40 40 0.040 GAX4 5C❹ 5 5 0.0 ❶ For GA06 A-GA040 A only. ❷ For GA06 C-GA040 C only. ❸ For GA063 A-GA5 A only. ❹ For GA063 C-GA5 C only. Add-on blocks/accessories page -6 to 9 page D-4 Wiring diagrams page W- Technical characteristics page TC-3 REV. 0_

electric 9 / 0 For photovoltaic applications -5 Three-pole switch disconnectors GA5 D Order code Conventional Rated operational Qty Wt free air current Ie per thermal current Ith DCB (800V) Poles in series 4 p 6 p 8 p [A] [A] [A] [A] n [kg] Direct operating version, complete with black handle. For door-coupling version, separately order the handle and shaft extension; refer to page -8 and -9. 40 5 5 35 0.35 80 8 30 40 0.355 GA5 D 5 0 35 45 0.355 General characteristics 40A to 5A ratings Available versions: direct operating door coupling version. Use switch disconnector with direct actuator and separately order the handle and shaft extension for this version. See page -8. Screw or 35mm DIN (IEC/EN 6075) rail fixing Padlockable in 0 position with no extra accessory. Operational characteristics Rated insulation voltage Ui: 000V Rated impulse withstand Uimp: 8kV Mechanical life: 00,000 cycles for 30,000 cycles for and GA5 D. Fourth pole add-on Simultaneous closing operation as switch poles. For GA...D versions. GAX4 040D 40 0.040 GAX4 080D 80 0.0 GAX4 5D 5 0.0 Trasformation of direct operating version into door coupling type GA5 D + with GAX60 00 for 6 and 8 poles GAX4...D (GAX64...) GAX4 040D GAX4 040D GAX60 00 / GA5 D GA5 D / GA5 D GAX4 080D / GAX4 5D / GA5 D / GA5 D GAX4 040D GAX60 00 / GA5 D GAX60 0 GAX4 080D / GAX4 5D UTILISATION IN DCB CATEGORY Operational Maximum operational current voltage in a configuration with: Ue [V] [A] [A] [A] 3 POLES IN SERIES. Products to GA5 D purchase and fit together 48 40 80 5 0 35 70 0 0 3 40 95 4 POLES IN SERIES. Products to + + GA5 D + purchase and GAX4 040D GAX4 080D GAX4 5D fit together 400 35 40 64 440 3 40 64 500 3 40 56 600 0 30 40 700 5 8 0 750 5 8 0 800 5 8 0 6 POLES IN SERIES. Products to + + GA5 D + purchase and + + GA5 D + fit together GAX60 00 GAX60 0 GAX60 0 600 35 40 45 700 5 30 35 750 5 30 35 800 5 30 35 000 0 0 5 8 POLES IN SERIES. Products to + + GA5 D + purchase and + + GA5 D + fit together GAX4040D+ GAX4080D+ GAX45D+ GAX4 040D + GAX4 080D + GAX4 5D + GAX60 00 GAX60 0 GAX60 0 700 35 40 45 750 35 40 45 800 35 40 45 000 5 30 3 GA5 D GAX7... ( 5mm) GAX60 B GAX6... (GAX63... only) GAX6... + / GA5 D + GA5 D with GAX60 0 for 6 and 8 poles GAX750A GAX700A GAX7300A ( 7mm) GAX63... GAX63... GAX64... GAX66 GAX66 B Certifications obtained: GOST; culus (to UL508/CSA C. n 4 for and GAX4 040D; to UL98/CSA C. n 4 for, GA5 D, GAX4 080D and GAX4 5D). Compliant with standards: IEC/EN 60947-, IEC/EN 60947-3, UL508, UL98, CSA C.. GAX60 0 GAX4 080D / GAX4 5D Add-on blocks/accessories page -6 to 9 page D-4 Wiring diagrams page W- Technical characteristics pages TC-3 and 7 REV. 0_

-6 electric 6A to 5A switch disconnectors Add-on blocks and accessories 9 / 0 Add-on blocks and accessories GAX0 A GAX3...A GAX 0EA GAX 0EA GAX50... GAX60... GAX0 C GAX3...C Order code Characteristics Qty Wt per n [kg] Auxiliary contacts, simultaneous operation as switch poles. GAX0 A NO+NC for GA...A and GA...D 0.030 GAX0 C NO+NC for GA...C 0.030 Auxiliary contacts, early-break operation with respect to switch poles. GAX 0EA EB (NO) for GA06 A-GA040 A 0.035 and GAX 0EA EB (NO) for GA063 A-GA5 A, 0.035 and GA5 D Neutral terminal. GAX3 A For GA06 A-GA040 A and GA040D 0.040 GAX3 A For GA063 A-GA5 A and 0.0 - GA5 D GAX3 C For GA06 C-GA040 C 0.040 GAX3 C For GA063 C-GA5 C 0.0 Earth terminal. GAX33 A For GA06 A-GA040 A and GA040D 0.040 GAX34 A For GA063 A-GA5 A and 0.0 - GA5 D GAX33 C For GA06 C-GA040 C 0.040 GAX34 C For GA063 C-GA5 C 0.0 Mechanical interlock for line changeover (I-0-II). GAX50 00 For GA06 A-GA040 A, 0.050 and GAX67 B; 5mm ❶ GAX50 0 For GA063 A-GA5 A, 0.075 GA5 D and GAX67 B; 5mm ❶ Mechanical coupling system for 6-8 pole switch disconnectors. GAX60 00 For GA06 A-GA040 A, ; 0.050 5mm ❶ GAX60 0 For GA063 A-GA5 A,, 0.075 GA5 D; 7mm ❷ ❶ Use GAX7 shaft extensions. ❷ Use GAX66.. handles and GAX7 A extensions for a door-coupling version. General characteristics of auxiliary contacts Conventional free air thermal current Ith: 0A IEC/EN 60947-5- designation: A600-Q600. Transformation of direct operating versions into door couplimg types GA063 A-GA5 A + GA063 A-GA4 A / + / GA5 D + GA5 D with GAX50 0 for line changeover GAX7... ( 5mm) GA06 A-GA040 A + GA06 A-GA040A / + with GAX50 00 for line changeover Certifications obtained: GOST; culus (to UL508/CSA C. n 4 standards for auxiliary contacts, neutral terminal GAX3..., earth terminal GAX33..., interlock GAX60 00 and coupling system GAX50 00; to UL98/CSA C. n 4 for neutral terminal GAX3..., earth terminal GAX34..., interlock GAX50 0 and coupling system GAX60 0). Certifications pending: culus for GAX 0EA and GAX 0EA. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-3, UL508, UL98, CSA C.. 0 GAX67 B I 0 I GA06 A-GA5 A, GA080D and GA5 D Sequence and maximum combination of accessories on direct operating switch disconnectors Left side Switch disconnector Right side Fourth pole is always mounted directly on the switch side. Refer to page -4. Auxiliary contacts GAX0 A are always mounted directly on the fourth pole side, if any, or on the switch side. For GA06...GA040, neutral and earth on the fourth pole side, if any, or on the switch side. It is indifferent whether the first is the neutral terminal or earth terminal. For GA063...GA5, neutral and earth on the fourth pole side but NOT when auxiliary contacts GAX0 A are fitted. It is indifferent whether the first is the neutral terminal or earth terminal. GAX3 A GAX33 A GAX0 A GAX4 040A GAX4 040A GAX0 A GAX33 A GAX3 A ❸ GAX4 040A/D GAX4 040A/D ❸ GA06 A GA05 A GA03 A GA040 A GAX3 A GAX34 A GAX0 A GAX4 5A GAX4 5A GAX0 A GAX34 A GAX3 A ❸ GAX4...A/D GAX4...A/D ❸ GA063 A GA080 A GA00 A GA5 A GA5 D ❸ Contact our Customer Service (Tel. +39 035 484; email: service@lovatoelectric.com) for combinations with GAX 0EA and GAX 0EA contact types. pages D-4 and 5 Wiring diagrams page W- REV. 0_

electric 9 / 0 6A to 5A switch disconnectors Add-on blocks and accessories -7 GA06 C-GA5 C Sequence and maximum combination of accessories on door-mounting switch disconnectors Left side Switch disconnector Right side Fourth pole is always mounted directly on the switch side. Refer to page -4. Auxiliary contacts GAX0 C are always mounted directly on the fourth pole side, if any, or on the switch side. For GA06 GA040, neutral and earth on the fourth pole side, if any, or on the switch side. It is indifferent whether the first is the neutral terminal or earth terminal. For GA063 GA5, neutral and earth on the fourth pole side but NOT when auxiliary contacts GAX0 C are fitted. It is indifferent whether the first is the neutral terminal or earth terminal. GAX3 C GAX33 C GAX0 C GAX4 040C GAX4 040C GAX0 C GAX33 C GAX3 C GAX4 040C GAX4 040C GA06 C GA05 C GA03 C GA040 C GAX3 C GAX34 C GAX0 C GAX4 5C GAX4 5C GAX0 C GAX34 C GAX3 C GAX4 5C GAX4 5C GA063 C GA080 C GA00 C GA5 C GA06 A-GA040 A, with GAX50 00 and GAX60 00 Sequence and maximum combination for mechanical coupling system and mechanical interlock for line changeover Left side Switch disconnector Right side GAX3 A GAX33 A GAX0 A GAX4 040A GAX4 040A GAX0 A GAX33 A GAX3 A ❶ GAX4 040A/D GAX4 040A/D ❶ GA063 A-GA5 A,, GA5 D with GAX50 0 and GAX60 0 Fourth pole is always mounted directly on the switch side. Refer to page -4. Auxiliary contacts GAX0 A are always mounted directly on the fourth pole side, if any, or on the switch side For GA06...GA040, neutral and earth on the fourth pole side, if any, or on the switch side. It is indifferent whether the first is the neutral terminal or earth terminal. For GA063...GA5, neutral and earth on the fourth pole side but NOT when auxiliary contacts GAX0 A are fitted. It is indifferent whether the first is the neutral terminal or earth terminal. GAX50 00 - GAX60 00 GA06 A GA05 A GA03 A GA040 A GAX3 A GAX34 A GAX0 A GAX4 5A GAX4 5A GAX0 A GAX34 A GAX3 A ❶ GAX4...A/D GAX4...A/D ❶ GAX50 0 - GAX60 0 GA063 A GA080 A GA00 A GA5 A GA5 D ❶ Contact our Customer Service (Tel. +39 035 484; email: service@lovatoelectric.com) for combinations with GAX 0EA and GAX 0EA contact types. pages D-5 REV. 0_

-8 electric 6A to 5A switch disconnectors Handles 9 / 0 Handles Order code Characteristics Qty Wt per n [kg] DOOR COUPLING HANDLES, PADLOCKABLE, IP65. Red/yellow, rotating. GAX6 For GA...A, GA...C and GA...D 0.073 Screw fixing. Recessed selector. 5mm ❶ GAX6 GAX6 For GA...A, GA...C and GA...D 0.07 Screw fixing. Protruding selector. 5mm ❶ GAX63 For GA...A, GA...C and GA...D 0.068 Ring fixing. Protruding selector. 5mm ❶❷ GAX63 For GA...A and GA...D. 0.057 Low-profile ring fixing. Protruding selector. 5mm ❶ GAX64 For GA...A, and GA...D 0.064 GAX6 Ring fixing. Protruding selector with release, defeatable per UL508A; 5mm ❶ GAX66 For GA063 A-GA5 A, 0.40, GA5 D and GAX60 0. Screw fixing. Pistol grip with release, defeatable UL508A; 7mm ❸ Black, rotating. GAX6 B For GA...A, GA...C and GA...D 0.073 GAX63... B Screw fixing. Recessed selector. 5mm ❶ GAX6 B For GA...A, GA...C and GA...D 0.07 Screw fixing. Protruding selector. 5mm ❶ GAX63 B For GA...A, GA...C and GA...D 0.068 Ring fixing. Protruding selector. 5mm ❶❷ GAX66 GAX63 B For GA A, GA06 C-GA040 C. 0.074 and GA D. Ring fixing. Protruding selector, padlockable at ON (per UNI 9490 and UNI EN 845 - firefighting systems); 5mm ❶❷ GAX63 B For GA...A and GA...D. 0.057 Low-profile ring fixing. Protruding selector. 5mm ❶ GAX64 B For GA...A and GA...D 0.064 Ring fixing. Protruding selector with release, defeatable per GAX67 B UL508A. 5mm ❶ GAX66 B For GA063 A-GA5 A and 0.40 -GA5 D and GAX60 0. Screw fixing. Pistol grip with release, defeatable per UL508. 7mm ❶ GAX67 B For GAX50... mechanical 0.078 interlock mechanism (I-O-II). 5mm ❶ ACCESSORIES FOR DOOR COUPLING CONTROL. For GAX66 and GAX66 B handles. GAX60 B Adapter 7mm for 0.00 GA063 A-GA5 A, and GA5 D ❶ For GA...A and GA...D switch disconnectors, separately order GAX7... shaft extensions. ❷ Snap-on fixing of GA06-GA040C switch disconnectors with the handle. ❸ Separately order GAX7 A shaft extension and GAX60 B handle having a 7mm square section, except for use with GAX60 0. Transformation of direct operating version into door coupling type GA5 D GA...A GA...D GAX7... ( GAX60 B Door-mount version 5mm) (GAX63...) (GAX63 B) GA...C (GAX64) GAX6... GAX6... GAX6... + / GA5 D + GA5 D with GAX60 0 for 6 and 8 poles GAX750A GAX700A GAX7300A ( 7mm) GAX63... GAX63 B GAX6... GAX63... GAX63 B GAX63... GAX64... GAX66 GAX66 B Certifications obtained: GOST; culus (to UL508/CSA C. n 4 for products used with GA06... Ga040...; to UL98/CSA C. n 4 for products used with GA063... GA5...) except GAX63 B. Certifications pending: culus for GAX63..., GAX66... and GAX60B. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-3, UL508, UL98, CSA C.. pages D-4 REV. 0_

electric 9 / 0 6A to 5A switch disconnectors Accessories -9 Accessories GAX7... GAX7... A GAX8... Order code Characteristics Qty Wt per n [kg] Shaft extension for door-coupling handles GAX6-GAX64, GAX6 B-GAX64 B, GAX67 B and mechanical interlock type GAX50 00, GAX50 0 and coupling system GAX60 00. GAX7 055 55mm long; 5mm 0,0 GAX7 070 70mm long; 5mm 0.04 GAX7 090 90mm long; 5mm 0.08 GAX7 50 50mm long; 5mm 0.03 GAX7 00 00mm long; 5mm 0.040 GAX7 300 300mm long; 5mm 0.068 GAX7 400 400mm long; 5mm 0.07 GAX7 500 500mm long; 5mm 0.090 Shaft extension for door-coupling handles GAX66, GAX66 B and mechanical coupling system GAX60 0. GAX7 50A 50mm long; 7mm 0.090 GAX7 00A 00mm long; 7mm 0. GAX7 300A 300mm long; 7mm 0.60 Set of three-pole terminal covers. GAX83 For GA06 A-GA040 A, 0.08 GA06 C-GA040 C, GAX84 For GA063 A-GA5 A, 0.030 GA063 C-GA5 C,, GA5 D Set of one-pole terminal covers for fourth pole. GAX8 For GAX4 040A, GAX4 040C 0.009 GAX4 040D, GAX4 040A, GAX4 040C GAX8 For GAX4 063A-GAX4 5A, 0.0 GAX4 063C-GAX4 5C, GAX4 080D, GAX4 5D, GAX4 5A, GAX4 5C Fuse holder for switch disconnectors. GAX39 For GA06 A-GA03 A ❶ Suitable for 0.3x38 fuse size GAX39 UL For GA06 A-GA03 A ❶ Suitable for Class CC fuses ❶ Contact our Customer Service (Tel. +39 035 484; email: service@lovatoelectric.com). Operational characteristics of fuse holder Rated insulation voltage Ui: 000V Rated impulse withstand voltage Uimp: 8kV The fuse holder connects directly to the switch disconnectors Access to fuses only when the switch disconnectors are in OFF position. Terminal covers For switch disconnectors GA...A GA...D GAX83 GAX84 For fourth pole GAX4...A GAX4...A GAX4...D GAX8 GAX8 GAX83 GAX84 GA...C GAX8 GAX8 GAX4...C GAX4...C Certifications obtained: GOST; culus (to UL508/CSA C. n 4 for products used with GA06... GA040...; to UL98/CSA C. n 4 for products used with GA063... GA5...). Certifications pending: culus for GAX7...A and GAX39 UL types. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-3, UL508, UL98, CSA C.. GAX39 pages D-5 Wiring diagrams page W- REV. 0_

-0 electric 6A to 5A switch disconnectors In housing - Empty enclosures 9 / 0 Three-pole switch disconnectors in housing GAZ06...-GAZ040... GAZ063...-GAZ5... Order code Conventional free air thermal Qty Wt current Ith per ACA ( 690V) [A] n [kg] THREE POLE. With rotating red/yellow handle. GAZ06 6 0.450 GAZ05 5 0.450 GAZ03 3 0.450 GAZ040 40 0.450 GAZ063 63.0 GAZ080 80.0 GAZ00 00.0 GAZ5 5.0 With rotating black handle. GAZ06 B 6 0.450 GAZ05 B 5 0.450 GAZ03 B 3 0.450 GAZ040 B 40 0.450 GAZ063 B 63.0 GAZ080 B 80.0 GAZ00 B 00.0 GAZ5 B 5.0 FOUR POLE. With rotating red/yellow handle. GAZ06 T4 6 0.550 GAZ03 T4 3 0.550 GAZ063 T4 63.500 GAZ5 T4 5.500 With rotating black handle. GAZ06 T4B 6 0.550 GAZ03 T4B 3 0.550 GAZ063 T4B 63.500 GAZ5 T4B 5.500 Components Enclosure Switch Handle disconnector GAZ GA06 A GAX6 GAZ GA05 A GAX6 GAZ GA03 A GAX6 GAZ GA040 A GAX6 GAZ3 GA063 A GAX6 GAZ3 GA080 A GAX6 GAZ3 GA00 A GAX6 GAZ3 GA5 A GAX6 GAZ B GA06 A GAX6 B GAZ B GA05 A GAX6 B GAZ B GA03 A GAX6 B GAZ B GA040 A GAX6 B GAZ3 B GA063 A GAX6 B GAZ3 B GA080 A GAX6 B GAZ3 B GA00 A GAX6 B GAZ3 B GA5 A GAX6 B GAZ GA06 A GAX4040A GAX6 GAZ GA03 A GAX4040A GAX6 GAZ3 GA063 A GAX4063A GAX6 GAZ3 GA5 A GAX45A GAX6 GAZ GA06 A GAX4040A GAX6 B GAZ GA03 A GAX4040A GAX6 B GAZ3 GA063 A GAX4063A GAX6 B GAZ3 GA5 A GAX45A GAX6 B Empty enclosures GAZ... Order code Description Qty Wt per n [kg] For switch disconnectors. With rotating red/yellow handle. Complete with shaft extension. GAZ For GA06 A-GA040 A and 0.30 GAZ3 For GA063 A-GA5 A,.900 and GA5 D With rotating black handle. Complete with shaft extension. GAZ B For GA06 A-GA040 A and 0.30 GAZ3 B For GA063 A-GA5 A,.900 and GA5 D General characteristics Polycarbonate housing material Three-pole versions can become four pole by adding the fourth pole GAX4...A One auxiliary contact block can be fitted on the right and left sides of the disconnector, unless the fourth pole already is fitted on GAZ...T4 types Padlockable handle Sealable cover IP65 degree of protection Entries GAZ06-GAZ040: PG6/M5 and PG3.5/M0 knockouts GAZ063-GAZ5: smooth surface to be drilled by the user GAZ: PG6/M5 and PG3.5/M0 knockouts GAZ3: smooth surface to be drilled by user. The empty enclosures are supplied with the following accessories: Enclosure GAZ B GAZ3 B GAZ GAZ 3 GAX6 B handle GAX6 handle Shaft extension Neutral terminal Earth terminal Certifications obtained: GOST; culus (see below). Compliant with standards: IEC7EN 60947-, IEC/EN 60947-3. GAZ3... Special GAZ... versions In addition to the standard-supplied types, culus certified versions are available (culus pending GAZ3... and GAZ63... - GAZ5... types). Add suffix UL at the end of the order code; e.g. GAZ03 B UL. page D-5 Wiring diagrams page W- Technical characteristics page TC-3 REV. 0_

6A to 5A switch disconnectors In housing - Empty enclosures - Maximum combinations Enclosures Sealing eyelet GAX0 A GAX4 040A GAX4 040A GAX4 040D or GAX 0EA GAX83 GAX8 GAZ06-GAZ040 GAZ06 B-GAZ040 B GAZ GAZ B One auxiliary contact block can be fitted on the right and left sides of the disconnector unless the fourth pole is fitted. The earth and neutral terminals are standard supplied on the enclosure base. GAX 0EA or Sealing eyelet GAX34A GAX0 A GAX3A GAX4 5A GAX4 63A- GAX4 5A GAX4 080D GAX4 5D GAX83 GAX84 GAZ063-GAZ05 GAZ063 B-GAZ05 B GAZ3 GAZ3 B Two auxiliary contact blocks can be fitted both on the right and left sides of the disconnector. Earth and neutral terminals, if any, are to be purchased separately for the enclosure except for GAZ...UL types which have them standard supplied. Lovato_Switch_Disconnectors_6-5A_en_09.pdf Helsinki tel. +358 9 540 4940 automation@klinkmann.fi St. Petersburg tel. +7 8 37 375 klinkmann@klinkmann.spb.ru Moscow tel. +7 495 64 66 moscow@klinkmann.spb.ru Yekaterinburg tel. +7 343 376 5393 yekaterinburg@klinkmann.spb.ru Samara tel. +7 846 73 95 85 samara@klinkmann.spb.ru Кiev tel. +38 044 495 33 40 klinkmann@klinkmann.kiev.ua Riga tel. +37 6738 67 klinkmann@klinkmann.lv Vilnius tel. +370 5 5 646 post@klinkmann.lt Tallinn tel. +37 668 4500 klinkmann.est@klinkmann.ee Мinsk tel. +375 7 00 0876 minsk@klinkmann.com