Assisted lift operated 2/2-way solenoid valves Type EV251B

Similar documents
Solenoid valves, 2/2-way servo-operated type EV220B 6-22

Assisted lift operated 2/2-way solenoid valves Type EV250B

MAKING MODERN LIVING POSSIBLE. Solenoid valves, 2/2-way assisted lift operated type EV251B Technical brochure

2/2-way assisted lift operated solenoid valve type EV250B

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

Solenoid valve Types EV220B 15 - EV220B 50

Solenoid valves 2/2-way servo operated type EV220B 15 50

Servo-operated 2/2-way solenoid valves Type EV220A

Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions

Solenoid valve Types EV220B 15 - EV220B 50

Type EV224B. Servo-operated 2/2-way solenoid valves for high pressure air. Data sheet

Servo-operated 2/2-way solenoid valves for high pressure

Solenoid valves for drinking water Types EV220BW and EV228BW

Servo piston operated 2/2-way solenoid valves for steam Type EV245B

Servo-operated 2/2-way solenoid valves for steam Type EV225B

Solenoid valves for water supply and steam inlet Types EV220T, EV220W, EV220B, EV225B, and AV210

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210B. February 2002 DKACV.PD.200.A B1504

Solenoid valves 2/2-way direct-operated Type EV210B

Solenoid valves 3/2-way direct-operated Type EV310A

Solenoid valves 2/2-way servo-operated Type EV220B 15-50

Solenoid valve VDHT Standard BSP (British Standard Pipe)

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210A DKACV.PD.100.A B1023. August 2001

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

Servooperated. 2/2-way solenoid valves EV220A. The Home of Control & Automation in Ireland

One. The performance of your wind turbine relies on the quality of its small components. ia.danfoss.com. Brochure Mobile Hydraulic

Nessie 2/2 way Solenoid valves for High Pressures and High Temperatures, type VDHT

3/2-Way Zone-Drain-Valves VDHT 2E, VDHT 15E and VDHT 15EC

Solenoid valves, type EVRA 3 40 and EVRAT REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Easy. Core Industrial Products for Distributors and Wholesalers. selection of future proof products. iasupport.danfoss.com

Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge"

High Capacity Valve Body, Type RA-G

Solenoid valves VZWM-L, NPT

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Pressure relief controller AVA (PN 25)

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

2/2-way Solenoid Valve with servo diaphragm

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

Solenoid valves VZWP, servo-controlled

ON/OFF zone valves AMZ 112, AMZ 113

PILOT OPERATED, 2/2 WAY, NORMALLY CLOSED, G 3/4 - G1. Pressure. Pressure Maximum For DC Voltage. Flow Coeffient. Maximum. For AC Voltage. L/m.

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

82170/ /2-way diaphgram valves

Flow-compensated temperature controller AVTQ DN 15

Valve bodies type RA-N with integrated presetting

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

Pressure reduction controllers (PN 25) AVDS - for steam AVD - for water

2/2-way and 3/2-way Normally Closed (NC) and Normally Open (NO)

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

Manual presetting valves LENO MSV-BD

Solenoid valves VZWM-L

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

Reliable season change

Solenoid valve for R410A and R744 Types EVR 2 - EVR 6 and EVRH 10 - EVRH 40

Coils for solenoid valves

Solenoid valve VDHT standard BSP (British Standard Pipe)

The precise step to take

Solenoid coil Types BB, BE, BF, BG, and BN

SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1

Solenoid coils. Data sheet

3/2-way Solenoid Valve, direct-acting, NC or NO

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Solenoid coils. Data sheet

Externally operated valves Type AV210

Solenoid valve type 150 direct action

MINIATURE SOLENOID VALVES diaphragm mechanism, fl uid isolation threaded connections M5-1/8

Manual presetting valve MSV-C

2/2 Pressure operated valves

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

3/2-way Solenoid Valve for pneumatics

Series PD directly operated solenoid valves

2/2 way Directional Control Valves, type VDH For inline mounting and Cetop 3 flange mounting (ISO 4401)

Technical Data Sheet

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)

Two- and three way valves VFG.. / VFGS 2 / VFU.. for self-acting thermostats and electrical actuators

High Pressure Valves

SonoSensor 30 Ultrasonic flow sensor

Flow controller (PN 25) AVQ - return and flow mounting

Solenoid valves VZWM-L

Series PD directly operated solenoid valves

Starting Torque Limiter Type TCI (Soft Start)

Solenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Series P directly operated solenoid valves

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Cartridge Valves Technical Information Directional Valves DCV 03

Solenoid valves Type EVU for fluorinated refrigerants

ZEUS type BRONZE PNEUMATIC ACTUATED VALVE

CI-TI Contactors and Motor Starters Type CI 6-50

Solenoid valves Type EVU

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT.

Condensed Catalog 2006 North America

2/2 or 3/2 way direct acting rocker solenoid valve

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

how to use solenoid valves INDUSTRIAL CONTROLS DKACV.PS.600.A3.02 / 520B1389

Type Modular Water Valve System servo-assisted; variable and extendable. 2/2 way; DN mm; 1 up to 7 bar Advantages / Benefits

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

MAKING MODERN LIVING POSSIBLE. Coils for solenoid valves. Technical brochure

Transcription:

Data sheet Assisted lift operated 2/2-way solenoid valves Type EV251B EV251B with assisted lift is especially suitable for applications such as closed systems with low and fluctuating pressure conditions or open systems with differential pressure down to 0 bar. EV251B valves are supplied complete, inclu ding coil and plug. Features and versions: For water, oil, compressed air and similar neutral media Flow range: 1.5 3.5 m 3 /h Differential pressure: 0 10 bar Media temperature from -10 90 C Ambient temperature: Up to 80 C Coil enclosure: IP65 Thread connections: From G ⅜ G 1 DN 10-22 Viscosity: Up to 50 cst Brass version, NC IC.PD.200.G7.02 1

Brass valve body, NC and BB clip on coil Connection ISO228/1 G 3 8 Seal material Orifice size kv - value [m³/h] 10 1.5 G 1 2 12 2.5 G 3 4 18 3.5 G 1 22 3.5 Differential pressure min. to max. [bar] 0 10 Coil voltage / power consumption BB coil Media temperature min. to max. [ C] -10 90 1) In water applications, exercise the valves at least once every 24 hours, meaning change the state of the valve. The valve exercise will minimize the risk of the valve sticking due to calcium carbonate, zinc or iron oxide build-up. Code number 032U538002 032U538016 032U538031 032U538102 032U538116 032U538131 032U538202 032U538216 032U538231 032U538302 032U538316 032U538331 Technical data, NC Main type EV251B 10B EV251B 12B EV251B 18B EV251B 22B Time to open [ms] 1) 50 60 200 200 Time to close [ms] 1) 300 300 500 500 1) The times are indicative and apply to water. The exact times will depend on the pressure conditions. Installation Vertical system is recommended Max. test pressure 50 Bar 16 Bar Ambient temperature Viscosity Materials 24 V DC. coil: Max 50 C 24 V / 230 V AC. coil: Max 80 C Max. 50 cst Valve body Brass W.no. 2.0402 Armature Stainless steel W.no. 1.4105/AISI 430FR Armature tube Stainless steel W.no. 1.4306/AISI 304L Armature stop Stainless steel W.no. 1.4105/AISI 430FR Springs Stainless steel W.no. 1.4310/AISI 301 O-rings Valve plate Diaphragm (only EV251B 10 - other versions are without O-ring IC.PD.200.G7.02 2

Dimensions and weight, brass NC Type Weight gross valve body with BB coil [kg] L L1 EV251B 10 0.58 51.5 84 48 46 13 81 EV251B 12 0.64 58.0 84 54 46 13 81 EV251B 18 0.94 90.0 84 62 46 18 87 EV251B 22 0.94 90.0 84 62 46 18 91 B B1 H1 H Dimensions Mounting angle Danfoss 32U1776.10 Below coils can be used with EV250B: Coil Type Power consumption Enclosure Features BB, clip on 10 W AC. 18 W DC. IP00 with spade connector IP20 with protective cap IP65 with cable plug IC.PD.200.G7.02 3

Universal electronic multi-timer, type ETM Application External adjustable timing from 1 to 45 minutes with 1 to 15 seconds drain open. With manual override (test button). Electrical connection DIN 43650 A / EN 175 301-803-A Voltage To use with coil: Ambient temperature [ C] Code number 24 240 V AC. BB -10 50 042N0185 y Outside adjustments. y Light weight and small size. y External adjustable timing from 1 minute to 45 minutes with 1 to 15 seconds drain open. y One solid state timer fits all coil voltages from 24 240 V AC. y Light diodes for indication. y All in one unit. y Manual override (test button). Technical data Type ET 20 M Voltage 24 240 V AC / 50-60 Hz. Power rating Max. 20 Watt Enclosure IP 00, IP 65 with cable plug Electrical connection DIN connector ( DIN 43650-A) Ambient operating temperature range -10 C 50 C Function Start with pulse Interval timer 1 45 min. On timer 1 15 sec. Weight 0.084 kg Dimensions, ETM timer IC.PD.200.G7.02 4

Function NC Coil voltage disconnected (closed): When the supply voltage to the coil (1) is disconnected, the valve plate (4) is pressed down against the pilot orifice (5) by the closing spring (3). The pressure across the diaphragm (6) is built up via the equalizing orifice (8). The diaphragm closes the main orifice (7) when the pressure above the diaphragm exceeds the inlet pressure below due to the larger diameter of the upper side and the compression of the closing spring (3). The valve will be closed for as long as the voltage to the coil is disconnected. 1. Coil 2. Armature 3. Closing spring 4. Valve plate 5. Pilot orifice 6. Diaphragm 7. Main orifice 8. Equalizing orifice 9. Assist 9.1 Assist spring 9.2 Assist connector Coil voltage connected (open): When the voltage is applied to the coil, the armature (2) and the valve plate (4) are lifted clear of the pilot orifice (5). If there is a differential pressure across the valve, the pressure across the diaphragm (6) drops because the pilot orifice is larger than the equalizing orifice. This causes the diaphragm to be lifted clear of the main orifice (7). If there is no differential pressure across the valve, the armature (2) draws the diaphragm (6) clear of the main orifice (7) using the assist spring (9.1) and assist connector (9.2). The valve will be open for as long as there is voltage to the coil. Capacity diagram 10-22: Example, water: Capacity for EV251B 10 at differential pressure of 4 bar. Approx. 3 m 3 /h EV251B 10 EV251B 12 EV251B 18-22 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. IC.PD.200.G7.02 5