Allegion LCN Benchmark AU9100 Series

Similar documents
Electro-Mechanical Swing Operator. Table of Contents

Dor-O-Matic. Series Slide Control. Installation Instructions

Dor-O-Matic. Series Slide Control. Installation Instructions

Dor-O-Matic. Astro-Fold Universal Control Box Instruction Manual Universal Control Box DOR - O - MATIC

9140 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

LCN AUTOMATIC OPERATORS

9550 SERIES FEATURES OPERATOR MOUNTS SIMULTANEOUS PAIR, SURFACE MOUNT *PULL SIDE PUSH SIDE DOUBLE EGRESS

*PULL SIDE mount shown

SENIOR SWING UNIQUE FEATURES

9530 Series Senior Swing. Features. Special Templates. Fasteners Mounting. Certifications

9540 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

Senior Swing Control Box. Table of Contents

9550 Series Senior Swing. Features. Special Templates. Certifications. Fasteners Mounting

LCN 9540 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

LCN 9140 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

9560 Series Senior Swing. Features. Special Templates. Cover Fasteners Mounting. Certifications

KEANE MONROE a member of the record group

Dor-O-Matic. Senior-Swing Universal Control Box. Instruction Manual Universal Control Box DOR-O-MATIC

LCN 9130 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PULL) OFFSET PIVOT/BUTT HINGE

Dor-O-Matic. Astro Swing Universal Control Box. Instruction Manual Universal Control Box

Connected To Control Box Series. Closer. Set Screw. Arm Screw. Right Hand Shown. 1/8" I.D. Air Inlet Tubing Connected To Control Box

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

4040XPT Series Door controls

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

*24828* 1 Installation. Left Hand Shown, Right Hand Opposite. Customer Service

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

LCN 2810 SERIES OPERATOR MOUNTS SINGLE DOOR, OVERHEAD CONCEALED CENTER PIVOT ARM OFFSET PIVOT/BUTT HINGE

LCN 9740 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

9550 SERIES FEATURES OPERATOR MOUNTS SIMULTANEOUS PAIR, SURFACE MOUNT *PULL SIDE PUSH SIDE DOUBLE EGRESS

HOW TO TELL HAND OF DOOR:

5600 Series Power Operator Installation and Instruction Manual

*CENTER PIVOT arm shown

Hunter Automatics HA-8. Installation Manual

2860 SERIES FEATURES OPERATOR MOUNTS INDEPENDENT PAIR, OVERHEAD CONCEALED *CENTER PIVOT OFFSET PIVOT/BUTT HINGE

*24213* 4040-SE Sentronic. 1 Voltage. 6 Adjusting Hold-Open Door Position. 7 Regulation. 2 Tracking. 8 Door Closer Cover.

4031 Series Door controls

Power drill Center punch Wire stripper

INSTALLATION GUIDE For Surface Mounted Applications (Purchased after 08/01/2018)

SW10 (Full Power) & SW19 (Low Energy)

AL(689) DKBRZ(695) DKBRZ(695) LTZPC(691) AL(689) DKBRZ(695) AL(689) DKBRZ(695)

Setup and Programming Manual

TS93 EMF T/PT/TDE. Surface applied door closer

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

2850 Series Senior Swing. Features. Special Templates. Certifications. Fasteners Mounting

*70954* 240V Senior Swing Control Box Installation Instructions CAUTION WARNINGS. Table of Contents

Electrohydraulic Powered Systems

Automatic Sliding Door Retrofit Drive Assembly. Installation Manual DoorControlsUSA.com

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

*28101* 4600 Electronic Low Energy Operator Installation Instructions 4630 PULL SIDE MOUNT 4640 PUSH SIDE MOUNT. Table of Contents.

R231 A.V.R. Installation and maintenance R 231. This manual is to be given to. the end user. Armature 6- Field. Slow-blow fuse 250V 8 A

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

Installation Instructions Series 78-B/FHA Hold Open

Series 9540 J9540. Installation Instructions Multi-Sized 1 to 6 Non-Hold Open. Regular Arm Applications. Parallel Arm Applications

1461 Series Door controls

*24191* 4040SEL Sentronic. 35 ft-lbs 48 N-m 62 N. Installation CAUTION. Customer Service. Installation Instructions

EB Conveyor Maintenance Guide

5700 Series Power Operator Stop (Push) Side Mount Installation and Instruction

SAFETY REASONABLE EFFORT. ANY BINDING, SAGGING, LOOSE HINGES, OR DAMAGED HINGES MUST BE REPAIRED BEFORE CONTINUING WITH THIS INSTALLATION!

4040XP Series Door controls

*29268* 4600CS Electronic Low Energy Operator 4630CS PULL SIDE MOUNT 4640CS PUSH SIDE MOUNT. Table of Contents. Customer Service

Series 4100 Surface Applied Swing Door Operator with C4190 Control

Troubleshooting Guide

JACKSON CORPORATION Series

INSTALLATION INSTRUCTIONS

Series 2003T. Belt Drive Telescoping Slide Door INSTALLATION INSTRUCTIONS. To be used with H210 C2150 Ver.10 Control Setup Instructions

NON-SIZED SIZED HANDED

*CENTER PIVOT arm shown

1130 Series Door controls

ADA EZ Rev. H, 8/23/11

Automatic Sliding Door Owner s Manual

Full-featured operator with slim profile for moderate to high traffic applications LOW ENERGY OPERATOR CATALOG

DC3210 Series. Multi-Sized 1 thru 6 DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) Recommended Closer Size

XR Conveyor Maintenance Guide

LCN 4010T SERIES HINGE (PULL) SIDE

ASSA ABLOY MPI (Infinite Hold Open Range) Support Unit Models. Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device

Shipped set to size 3. Standard closer offers 3 installation options. - Regular (Pull side) - Top Jamb (Push side) - Parallel Arm (Push side)

*HINGE (pull) side mount shown

6100 Series Swing Door Operator Installation Instructions

VOLT POT 1K R220. OPEN FOR 60 Hz STAB A.V.R. R220. Installation and maintenance

1120 Series Door controls

Standard closer offers 3 installation options. - Regular (Pull side) - Top Jamb (Push side) - Parallel Arm (Push side)

CONCEALED CLOSER SERIES

7100SZ Series SafeZone Installation and Instruction Manual

Linear Actuator Swing Gate Operator Installation Manual Model # LA405-24

CABINET REEL OPERATING INSTRUCTIONS

Hinge (Pull) Side Door Application DC6230 Series Multi-Sized 1 thru 6 DC6430 Series Half-Size 1 thru 6. Door Mounted DC6230 & DC6430

LCN 4310ME SERIES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled. closer/holder designed to provide

ASSA ABLOY Universal Door Closers

COOKSON OWNER'S MANUAL

GLM SERIES CONTROL Users Manual Rev:

IB INTERNATIONAL Pty Ltd OCMIS INSTRUCTION MANUAL AQUA SYSTEM 3

RTS88. Overhead Concealed Door Closer

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE

ASSA ABLOY Universal Door Closers with Heavy Duty Spring Stop Parallel Arms

LCN 4310ME SERIES FEATURES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled

NON-SIZED SIZED HANDED

Transcription:

Allegion LCN Benchmark AU9100 Series Low Energy Operators Installation Manual LCN Low Energy Operators should be installed in accordance with the current Allegion LCN installation instructions. Commissioning and Servicing of installed units must be carried out by an Allegion Approved, Authorised Technician 16-20 Third Ave, Sunshine, Vic, 3020 Tel: 1800 098 094 Email: auinfo@allegion.com Page 1 of 20 December 2014 Ver 4

1 GENERAL... 2 2 REPLACEMENT PARTS AND SYSTEM COMPONENTS... 3 3 PRE-INSTALLATION SITE AND PRODUCT CHECK... 4 4 OPERATOR INSTALLATION... 5 5 WIRING... 7 6 ARM AND COVER INSTALLATION... 8 7 OPERATIONAL CHECK... 10 8 OPERATOR ADJUSTMENT... 11 9 RELEASE FOR SERVICE... 13 10 LCN AU9100 (Briton 2500) V4 SOFTWARE... 14 1 GENERAL The LCN Benchmark 9100 Series is an automatic electromechanical swing door operator for use on hinged, centre pivoted, and offset pivoted doors. The controller is a microprocessor based system, tracking the door position at any time during the cycle. When activated the Benchmark 9100 drives the door to the full open position creating the potential energy in the spring. When closing the electrical power is reduced and the door closes by controlling the potential energy release in the spring force. The activating circuit opens the door from any position on the closing swing. During power failure the Benchmark 9100 acts as a manual door closer (size 3). Door opening and closing cycles, including opening speed, back check speed, hold open time delay, closing speed, and latch position are all adjustable. Warning WARNING Always disconnect main power to the operator prior to servicing or cleaning Swing door operator Pull arm and track assembly LCE65006 Swing door operator Push arm assembly LCE65007 Page 2 of 20 December 2014 Ver 4

2 REPLACEMENT PARTS AND SYSTEM COMPONENTS 9130 Series - (ANCLR or ANDKB only) 9130-3077T...Standard Arm 9130-3077PLCM...Standard Arm w/track 9130-3038...Track 9130-72MC*...Metal Cover 9130-72FC*...Full Metal Cover 9130-MS...Screw Pack 9130-73...Track End Cap 9130-163...Cover Insert 9130-163-1...Cover End Cap Insert 9130-334...Cover End Cap 9130-360...24v SO Kit 9130-3018...Mounting Bracket 9130-3155...Label Kit 9130-3034...Track Roller 9130-3351-1...Switch Bracket 29" 9130-3351-2...Switch Bracket 41" 9130-3351-3...Switch Bracket 51" 9130-3454...Motor Gearbox Assembly 9130-3454S...Motor Gearbox Assembly w/switch 9130-3462SC...Standard Control Box 9130-3498-2A...A/C Power Cable - 29" 9130-3498-2B...A/C Power Cable - 42" 9130-3498-2C...A/C Power Cable - 52" 9140 Series - (ANCLR or ANDKB only) 9140-3077...Regular Arm 9140-3077L...Long Arm 9140-72MC*...Metal Cover 9140-72FC*...Full Metal Cover 9140-MS...Screw Pack 9140-77...Main Arm 9140-79...Rod 9140-79LR...Long Rod 9140-163...Cover Insert 9140-163-1...Cover End Cap Insert 9140-334...Cover End Cap 9140-360...24v SO Kit 9140-3018...Mounting Bracket 9140-3155...Label Kit 9140-3351-1...Switch Bracket 29" 9140-3351-2...Switch Bracket 41" 9140-3351-3...Switch Bracket 51" 9140-3454...Motor Gearbox Assembly 9140-3454S...Motor Gearbox Assembly...w/Switch 9140-3462SC...Standard Control Box 9140-3498-2A...A/C Power Cable - 29" 9140-3498-2B...A/C Power Cable - 42" 9140-3498-2C...A/C Power Cable - 52" Page 3 of 20 December 2014 Ver 4

3 PRE-INSTALLATION SITE AND PRODUCT CHECK 3.1 Check that the product model is correct for the required application 3.2 Check that all parts listed for the installation are received 3.3 Check architectural drawings and final approved shop drawings for position of frame and structural openings 3.4 Check header and frame dimensions and required clearances Clearances for pull system Clearances for push system 3.5 Ensure door weight is less than 90Kgs. For heavier doors consult supplier 3.6 Check that a 240 Volt, single phase, 60 Hz, fused supply (5 amp fuse maximum) is available at the side of the jamb within approximately 1 Meter of the header. Approved type conduit is recommended for 240V systems 3.7 If an electric lock is to be connected to the system, the maximum current draw is 2 Amps. The switching relay contact is a maximum resistive current of 2 Amps. 3.8 The supply must be a dedicated circuit from the main circuit breaker panel and must not be connected into building lighting circuit with fluorescent lights Page 4 of 20 December 2014 Ver 4

4 OPERATOR INSTALLATION 4.1 Remove control box from mounting bracket, then remove Motor/Gearbox from bracket 4.2 Prepare header frame Pull system See Page 5 NOTE Push system See Page 6 NOTE For push units with a reveal greater than 150 mm refer to installation sheet included in the extended arm Packaging. 4.3 Install operator-mounting bracket on the header/frame. 4.4 Install motor/gearbox on operator mounting bracket, then install control box on bracket Go to wiring page 7 Pull System Framed Header and Door Preparation Page 5 of 20 December 2014 Ver 4

OPERATOR INSTALLATION (Cont) Push System Framed Header and Door Preparation REVEAL Butt Hung/Offset Pivot DIM A 25. 559 686 51 533 660 76 508 635 102 483 610 127 457 584 152 457 584 Centre Pivot DIM A Page 6 of 20 December 2014 Ver 4

C 5 WIRING CAUTION Make sure all wires are properly dressed and secured to prevent interference Route all wiring away from moving parts, sharp edges, and heat sources Use copper conductors only Do not modify the factory wiring or connect into existing electrical circuits or devices AUTION 5.1 Refer to the appropriate wiring diagram for the standard control box (Page 22) or the diagram supplied for custom applications. And connect the following cables Ground cable (Ground the operator properly with the earth from main supply Hall effect Cable (do not wrap the hall effect cable around the motor cable) Motor power cable (do not wrap the motor cable around the hall effect cable) Control box power cable 5.2 Connect Activate, Safety, Key switch, and lock accessories as needed. Refer to the accessory instruction/s for any accessories used. Do not connect any remote activating device to the door unless it is located within line of sight of the door 5.3 When wiring is complete go to Arm and cover installation on page 8 Page 7 of 20 December 2014 Ver 4

6 ARM AND COVER INSTALLATION WA WARNING Keep hands, clothing, wires, tools, ETC away from the operator motor when the operator is turned on RNING 6.1 Make sure the operator power switch is turned OFF 6.2 Install a jumper across the control box MAIN ACT T28 and COMMON T27 6.3 Turn the operator power switch on. The operator motor will activate and drive to the full open position. 6.4 Attach the arm to the operator spindle loosely with the 8-mm socket head screw (for push systems ensure adjusting boss is inserted correctly). 6.5 Attach the arm to the door 6.5.1 For push systems attach the push arm shoe to the door Page 8 of 20 December 2014 Ver 4

ARM AND COVER INSTALLATION (Cont) 6.5.2 For pull systems, slide the pull arm roller into the track, insert a track cap on each end of the track, and attach the track to the door. Pull Arm 6.6 Adjust the arm 6.6.1 For pull systems, remove the locking screw from the arm 6.6.2 For the push system remove the locking screw from the arm Pull Arm Push Arm 6.7 Keep the door in the full open position and adjust the arm length as necessary to align the door at 90 degrees from closed. When the arm is adjusted to the correct length, tighten up the 8mm socket head screw that secures the arm to the operator spindle and ensure this is secure, then tighten the arm locking screw 6.8 Turn off the power operator switch. The door closes 6.9 Remove the jumper from the control box T27, T28 6.10 Test the operator (See operational check on page 11) and continue with step 6. 10 6.11 Adjust the operator as required( see Operator Adjustment on page 12) and continue with step 6.12 Snap optional end cap insert (from screw bag) into the end cap opposite the on/off switch. 6.13 Install the cover assembly on the operator 6.14 Release the operator for service ( see Release for Service on page 14) Page 9 of 20 December 2014 Ver 4

7 OPERATIONAL CHECK 7.1 Set the Key switch to Auto (1 Way) and turn on the operator power switch 7.2 Activate the operator using the activation device, the operator will perform one sizing cycle Sizing cycle: Occurs after a legitimate activation signal is received, after power has been turned on. During the size cycle, the door opens and closes one time. 7.2.1 If the door does not open at all during sizing cycle 7.2.2 Check door for binding 7.2.3 If an electromechanical lock is being used, check that the lock disengages before the operator opens the door. 7.2.4 Check fuses, Circuit breakers, and connections. 7.2.5 Adjust the operator and check door operation (See Operator Adjustment on page xx) Opening speed 75% Back check speed 75% Hold open time delay Minimum Latch position Maximum Closing speed 50% SW1, 2, 3, 4 OFF If the door does not open fully during size cycle check the door for binds Increase the back check speed slightly and check door operation continue increasing back check speed until door opens fully 7.3 If the door slams open decrease the back check speed slightly and check door operation. Continue decreasing back check speed until the door opens without slamming 7.4 After the sizing cycle is complete and the door is closed, apply a maintained activation signal and check that the door remains open while the signal is applied. 7.5 If a door safety device is being used: 7.6 Door open safety 7.7 Door close safety When the door is in the closed position activate the safety device, then try to activate the door the door should remain closed. Activate the door, as the door is opening activate the safety device the door should stop, and then slowly drive to the full open position. Activate the door then maintain activation of the safety device, the door should open and remain open. As the door is closing, activate the safety device, the door should re-open to the open position, time out and then close. 7.8 When the door is operating properly, continue with step 6.10 on page 9 Page 10 of 20 December 2014 Ver 4

8 OPERATOR ADJUSTMENT See table below and diagrams on page 18 for operator feature adjustment. After adjustment, cycle the door several times and check for proper operation, then continue with step 6.11 on page 9. N NOTE Adjust operator for the slowest operation practical in accordance with the latest AS_5007 standards for powered doors for pedestrian access and egress. Opening speed 5 sec s or more Closing speed 3 sec s or more OTE Features Control Description Anti-Clockwise Clockwise Opening P1 Controls opening speed of door Slower Faster Speed Back Check Speed Hold Open Time Delay Auto Reverse setting Latch Position P2 P3 P4 P5 Controls speed of door near full open position to prevent door slamming open Controls length of time door remains in the full open position 1 to 30Sec Sets pressure required on door opening before door stops Determines distance at which the door begins to decelerate to full closed position to prevent door slamming Closing Speed Safety P7 Controls the angle during the Opening open cycle that safety operates Angle Safety P8 Controls the angle during the Closing close cycle that safety operates Angle Delayed SW1 Activation Push And Go SW2 When switched on, pushing the door open by 5 degrees causes the operator to open for the remainder of the open cycle Power boost On or OFF Power boost continuous or 5 Sec s Slower Less time 1 Sec Less Pressure required Less Latch Faster `More Time 30 Sec s More Pressure Required More Latch P6 Controls closing speed of door Slower Faster SW3 SW4 Enables or disables Power Boost which gives a force in the closed direction when the door is closed. Used for high wind situations Enables power boost to operate continuously or for 5 Sec s only after door closes. Closer to closed position Closer to open position Further from closed position Further from open position Page 11 of 20 December 2014 Ver 4

OPERATOR ADJUSTMENT (Cont) Page 12 of 20 December 2014 Ver 4

9 RELEASE FOR SERVICE 9.1 Remove all tools, installation equipment, and debris from the vicinity of the door. 9.2 Install all safety, traffic control, and instruction labels on the door as required by the latest AS_5007 Standard. Failure to do this leaves the installer LIABLE for any accident that might occur. This must be done. 9.3 Verbally instruct the owner or person in charge of the proper operation of the door. 9.4 Instruct the owner or person in charge to routinely inspect the door for the following Occasional damage Developing problems Minor preventative maintenance 9.5 Instruct the owner or people in charge who and where to call for service and maintenance when required. IMPORT ANT IMPORTANT Make sure to install all safety, traffic control and instruction decals on the door as required Page 13 of 20 December 2014 Ver 4

10 LCN AU9100 (Briton 2500) V4 SOFTWARE 10.1. OPERATION... 15 10.1.1. Sizing... 15 10.1.2. Auto Reverse on open... 15 10.1.3. Standard operation... 15 10.2. FUNCTION SELECTION... 16 10.2.1. Standard (0)... 16 10.2.2. Lock in OFF Only (1)... 16 10.2.3. Lock in 1 Way Only (2)... 16 10.2.4. PNG in OFF (3)... 16 10.2.5. Door closes and Unlocks in Fire Alarm (4)... 16 10.3. FUNCTION CHART... 17 10.4. CONTROL BOX SETUP... 18 10.5. LCN AU9100 (Briton 2500) ii WIRING... 19 Page 14 of 20 December 2014 Ver 4

10.1 OPERATION Notes 10.1.1 Sizing From start up (size) the door will activate from morning entry (24Hrs,T9, T10) regardless of key switch position, 1 Way input (T27,T28) with key switch in one way. 2 Way input (22, T23) with key switch in two way, or key switch Hold Open. The first movement will be in the open direction - The speed of the sizing cycle is automatic and cannot be set from a potentiometer the door drives opened to the full open position where the system sets the counter to full open. The door closes at close speed then latch up to closed position where the system sets the counter for closed position. From these two parameters opened and closed position the system calculates all the other parameters it requires for normal operation i.e. latch position back check position etc. If the encoder is connected for opposite direction or faulty or disconnected the door will operate erratically continuously opening ½ way closing latching and re-opening. This will continue to occur until power is switched off 10.1.2 Auto Reverse on open The auto reverse open is set from the backcheck position pot. This sets the level of current required to trip the door as it is opening. Normal operation Key switch, activation, morning entry/fire alarm, locking, and safety. 10.1.3 Standard operation Upon a legitimate activation signal the door accelerates up to open speed, monitoring the current load on the drive output. (If the current reaches a level above the set datum the door will stop and close). The door travels at the set speed (Potentiometer setting) until it reaches the set backcheck position, where the speed (Potentiometer setting) is decreased to back check speed. When the door stops at hold open position the system sets the hold open speed and holds the door open until activation and or timer is cleared. The door will then close at close speed, (Potentiometer setting) up to latch position (Potentiometer setting). Where the speed is decreased by driving the motor in the open direction (fixed setting), the power is set such that the spring will overcome this power and continue to allow the door to close up to the closed position. During the open cycle the safe opening (T1, T2) is active and the Safety side Adj Pot sets the angle at which the sensor is redundant, this can be set from Closed up to back check position. During the closing cycle the safe closing (T5, T6) is active and the Activate side Adj pot sets the angle the sensor is redundant, this can be set from Opened up to a few degrees of closed position. Page 15 of 20 December 2014 Ver 4

General 24Hr operates the door regardless of key switch position the door will drive open and remain in the open position as long as the contact is made (Program 4 is the exception) Key switch position OFF no activation or safety operates. Electric lock operates when door closed dependant upon function selection Electric lock operation is set from the function selector the time delay is fixed Key switch Position 1 Way the activation from internal Activate (T27, T28) safety operates. Electric lock operates when door closed dependant upon function selection Key switch Position 2 way the activation from internal Activate (T27, T28) and external Activation (T22, T23) safety operates. Electric lock does not operate when door closed Key Switch H.O The door operates to the open position and remains in the open position safety is by passed (If safety activated the door will open slowly) 10.2 FUNCTION SELECTION 10.2.1 Standard (0) Operates as a standard door with electric lock operating in OFF and 1 WAY Eyetech Activation T5, T6 (Closing Cycle) Eyetech Safety T1, T2 (Opening Cycle) F/A T9, T10 1 Way T27, T28 2 Way T22, T23 Door open T14 Key switch off T12 T8 Not Used 10.2.2 Lock in OFF Only (1) Operates as a standard door with electric lock operating in OFF only. This selection will give a fast activation in Auto or 1 Way from closed as there is no delay for lock operation. 10.2.3 Lock in 1 Way Only (2) Operates as a standard door with electric lock operating in 1 Way only 10.2.4 PNG in OFF (3) Operates as a standard with Push & Go operating in key switch OFF 10.2.5 Door closes and Unlocks in Fire Alarm (4) Operates as a standard Fire Alarm Normally closed if open circuit door closes and will remain Unlocked Page 16 of 20 December 2014 Ver 4

10.3 FUNCTION CHART Program BCD Operation Standard 0 Eyetech Act T1,T2 Eyetech Saf T5,T6 F/A T9,T10 1 Way T27,T28 Door open T14 Key switch off T12 2 Way T22,T23 T8 Not Used Locking in OFF only 1 As Std Door locks in OFF Only Locking Auto only 2 As Std Door Locks in AUTO Only Standard PNG in OFF 3 As Std PNG operates in key switch OFF Fire Alarm to close door Normally closed (Breakout) 4 As Std F/A T9,T10 Normally closed Door closes and remains unlocked 5 6 7 8 9 A B C D E F Page 17 of 20 December 2014 Ver 4

10.4 CONTROL BOX SETUP Page 18 of 20 December 2014 Ver 4

10.5 LCN AU9100 (Briton 2500) ii WIRING Page 19 of 20 December 2014 Ver 4

10.6 LCN AU9100 (Briton 2500) ii Terminal Block Page 20 of 20 December 2014 Ver 4