Portable Lamps Series HS6145, HSL145

Similar documents
Sheet Steel Emergency Light Fitting Series 6018

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

Type Scope of delivery Order unit Order No.

Compact Sheet-steel Emergency Light Fitting Series 6118/1

7 Lighting Technology

7 Lighting Technology

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Safety Switches Series 8537

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Compact Sheet-Steel Light Fittings Series 6114

Load disconnect switch Series 8146/5-V11

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Sheet-Steel Light Fittings Series 6014 / 6414

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Tank Inspection Lights Series 6122

7 Lighting Technology

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Light Fitting for Fluorescent Lamps Series 6009

Compact Sheet-Steel Light Fittings Series 6114/1

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

10 Load and Motor Switchgear

Terminal Boxes Series 8125

Floodlight LED Series 6525

Battery Boxes Series 8316

Load and Motor Switches, Load-Break Switches Series 8544

Terminal Boxes Series 8125

Ex UPS standard Series 8265

Plug and Socket Devices SolConeX 16 A Series 8570

Control switch/load disconnect switch Series 8008

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

11 Control Panels, Distribution Panels and Components

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Control Buttons / Switches for Panel Mounting Series 8003

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Floodlight LED Series 6525

Load and Motor Switches, Load-Break Switches Series 8544

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Floodlight LED Series 6125

Linear Luminaire with LED Series EXLUX 6402/2

Tubular Light Fitting with LED Series 6036

Operating Instructions

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Floodlight Series 6121

Load and Motor Switches, Load-Break Switches Series 8549

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

LED Linear Luminaire Series EXLUX 6402

Metal Position Switch Series 8074

Linear luminaire with LED Series EXLUX 6002

Control Buttons Series 8082

7 Lighting Technology

Position Switches Series 8060/2

Wolflite XT Rechargeable LED Handlamp

Linear Luminaire with LED Series EXLUX 6002

Position Switches Series 8070/2

ATEX II 2G Ex ib IIC T4 Gb. ATEX II 2D Ex ib IIIC T150 C Db ATEXBEAM

7 Lighting Technology

Floodlight Series 6521/4

Position Switches Series 8074/2

Operating Instructions

Operating Instructions

CEAG Products Main Catalogue Part 1 Chapter 1. Portable Ex-lighting

Hermetical Standard Chemical Pump of PTFE / PFA with permanent magnet synchronous motor ISO 2858 / DIN EN 22858

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

PRODUCT INFORMATION. Monitoring device ARM-2000

The modular structure makes it possible to build at least 5 configurations for each visual lens unit

Leading the way in hazardous areas Features EATON

EX-RECESSED CEILING LIGHT FITTINGS

HERION SERIES Indirect solenoid actuated soft seal

EX-REPAIR AND MAINTENANCE RECEPTACLES

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Control Device System NEC Series ConSig 8040

Operation Manual. TX40 and CX40

Solenoid Operator 0516 / 1216

Series 1 Examination Lamp. Series 2 Examination- and Reading Lamp. Series 3 Reading Lamp. Series 4 Reading Lamp. Series 5 Examination Lamp

Industrial Flashlights

Direct-acting 3/2 way plunger valve

3SE3 2 SIGUARD Position Switches

EX Series User Manual

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

Valve regulated Batteries for Stationary Applications. HAGEN dc plus. An EXIDE Company

International approvals.

Emergency lighting units PC COMBO

Operating Instructions

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

Unused flameproof threads for cable glands have to be closed with certified plugs.

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

Emergency lighting units PC COMBO

Transcription:

www.stahl.de > Portable Lamps Series HS6145 > Comply with requirements of Fire Department standard DIN 14462 > Battery state display > Open circuit monitor > Light intensity 15.000 cd after 4 hours use > NiCd battery, gas-tight > Charging unit available for stationary installation installation into vehicles > Portable Lamps Series HSL145 > Industrial design without explosion protection 10071E00 The electronics of portable lamps Series 6145 and Series L145 are resistant to electromagnetic fields, enabling the lamps to be used with radio equipment. ATEX Zone 0 1 2 20 21 22 Portable Lamp: For use in x x Charging Unit: For use in In non-hazardous area only! WebCode 6145A Lighting /1

Selection Table Version Description Order number Weight Explosion protected portable lamp kg with integrated monitoring electronics 6145/1 1.900 Charging unit* Industrial type portable lamps 02911E00 230 V, without emergency light 6145/91 2.080 230 V, with emergency light 6145/92 2.090 12 / 24 V, without emergency light ; for installation into vehicles 6145/93 1.800 with integrated monitoring electronics 1.900 without electronics 1.600 Charging unit* 02910E00 230 V, without emergency light for and L145/91 2.000 230 V, with emergency light for L145/92 1.800 12 / 24 V, without emergency light ; L145/93 1.000 for installation into vehicles 230 V, with emergency light only for L145/96 2.000 * Attention: Not for use in hazardous areas. Battery charging outside of hazardous area. Explosion Protection Marking Europe (ATEX) E II 2 G EEx e ib IIC T4 Not explosion protected Not explosion protected Certificates Europe (ATEX) PTB 03 ATEX 2150 Other certificates Kazakhstan (JSC) Certificate for motor vehicles e1*72/245*95/54*3406*00 e1*72/245*95/54*3406*00 e1*72/245*95/54*3406*00 /2 Lighting

Electrical data Battery Type Rated voltage Self - discharge Electronics Charge state display NiCd-battery gas-tight 4.8 V Ambient temperature at 20 C at 40 C Deep discharge protection When battery voltage is low, automatic switchover to economy lamp residual lighted time 10... 20 min Open circuit monitor If main lamp is faulty, switchover to economy lamp Light technical data Lamps Main lamp 4.8 V / 4 W (BA15d) 4.8 V / 4 W (BA15d) 4.8 V / 4 W (BA15d) Economy lamp 4.8 V / 1.5 W (BA9s) 4.8 V / 8 W (BA15d) 4.8 V / 8 W (BA15d) Rare-gas Light intensity approx. 15.000 cd to 4 h approx. 15.000 cd to 4 h approx. 15.000 cd to 4 h Range approx. 100 m bei 1 Lux approx. 100 m bei 1 Lux approx. 100 m bei 1 Lux Light aperture approx. 100 x 100 mm approx. 100 x 100 mm approx. 100 x 100 mm Luminance time per charge Main lamp Continuous light approx. 6... 8 h approx. 3 h approx. 3 h Flashing light approx. 23 h approx. 9 h Economy lamp Continuous light approx. 22 h approx. 22 h approx. 22 h Flashing light approx. 80 h approx. 80 h Functions Continuous or flashing light available with main or only continuous light available economy lamp Mechanical data Degree of protection IP54 Enclosure material Moulded material; non-abrasive, cold shock resistant; antistatic Head tilting forward: 20 back: 90 Accessories Diffusing lens; coloured lenses; warning light; all fitted into slots on lamp head Charging unit Version 6145/92 L145/92 6145/91 L145/91 L145/96 6145/93 L145/93 Application for stationary installation, with emergency light Discharge 50% after 6 weeks 50% after 2 weeks The battery charge level is indicated by 2 LEDs Battery charge LEDs level LED 1: LED 2: > 75 % ON ON > 25 % OFF ON < 25 % OFF OFF for stationary installation, without emergency light Attention: Not for use in hazardous areas. Battery charging outside of hazardous area. for stationary installation, without emergency light (halve charging current) Housing Moulded material, black, acid and caustic resistant, self extinguishing Main cable Length: 2 m; Europlug Length: 2 m; Europlug for installation into vehicles without emergency light Attention: Not for use in hazardous areas. Battery charging outside of hazardous area. Moulded material, black, acid and caustic resistant, self extinguishing Length: 2 m Lighting /3

Charging unit Version 6145/92 L145/92 6145/91 L145/91 L145/96 6145/93 L145/93 Function Charging starts when lamp is fitted into charger Charging starts when lamp is fitted into charger LED charge indicator no indicator LED charge indicator no indicator LED charge indicator Emergency light acc. to VDE 0108; if power supply is switched off, lamp fitted in charging unit becomes effective automatically without without without Rated voltage 230 V AC 50 Hz / 60 Hz 230 V AC 50 Hz / 60 Hz II (all - insulated) Protection class II (all - insulated) Charging time 230 V AC: 14 h 230 V AC: 14 h Charging current Constant-current Constantcurrent 230 V AC: 700 ma 230 V AC: 350 ma Protection category IOI 0.51 Ah / day (Charge 1 / 2 h at 700 ma, 16 h interval) Installation free installation or wall mounting possible Interference suppression acc. to VDE 0875 12 / 24 V, DC (selectable) III (Extra-low voltage) 12 V DC: 14 h; 24 V DC: 25 h Constant-current 12 V DC: 700 ma; 24 V DC: 400 ma Accessories and Spare Parts Designation Illustration Description Order number Weight kg Auxiliary lens granulated; fits into slots on lamp head clear 107226 0.500 red 107227 0.030 05619E00 green 107230 0.030 blue 107228 0.030 orange 107229 0.030 Warning light hood fits into slots on lamp head; colour: orange deflect light by 120209 0.093 90, for all-round illumination, for use as a warning light where there are obstacles Incandescent lamps Battery 1) Main cable 05618E00 05623E00 05624E00 05613E00 Power saving lamp: 4.8 V / 1.5 W BA9s 120221 0.035 Main lamp: 4.8 V / 4 W BA15d 120229 0.030 Main lamp: 4.8 V / 8 W BA15d 120235 0.026 Main lamp: 4.8 V / 8 W BA15d (Rare-gas) 120237 0.026 1) with screw and spring terminals NiCd, gas-tight 120148 0.880 NiCd, gas-tight 120142 0.945 NiCd, gas-tight with charging unit for 6145/2 120153 0.800 for 6145/2 105504 0.080 05880E00 /4 Lighting

Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 04805E00 04806E00 04811E00 Portable lamp 6145, L145 Charging unit for portable lamp 6145, L145; not useable in hazardous area Wall mounting of charging unit We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Lighting /5