M8, M Miniature, 22 mm normally closed and normally open models Sub-base mounted and manifold mounted 32 Poppet Valves Electrically Actuated M5 Manual override as standard Encapsulated coils with very rapid fitting Technical Data Medium: Compressed air, filtered, lubricated and non-lubricated Operation: Poppet valve, directly actuated with spring return Mounting: Through-holes with thread in sub-base Port Size: M5 Operating Pressure: 0-10 bar M8, DM8 0-7 bar M, DM Flow (to CETOP RP50P): Conductance dm 3 sbar 0,26 M8, DM8 Conductance dm 3 sbar 0,27 M, DM Critical pressure ratio 0,23 M8, DM8 Critical pressure ratio 0,117 M, DM Cv 0,067 Cv 0,0-7 Operating Temperature: 5 C* to +50 C supply air +5 C to +50 C ambient *Consult our Technical Service for use below +2 C Materials Plastic encapsulated coil, moulded plastic manual override base, stainless steel armature tube and spring, aluminium sub-base, nitrile rubber seals. 3 Ordering Information To order, quote model number followed by voltage code shown in the tables overleaf, e.g. M8167 for a normally closed low power model suitable for a 220V 50Hz electrical supply. Replacement coil and terminal box assemblies can also be supplied, quote required model number with Q prefix before the M and 28 suffix after the voltage code as shown in the table overleaf. For manifold models order the required number as indicated by the T suffix in the model number, e.g. off QM81028 for DM10T. 2 1 10 5..021.01
M8, M General Information Model Operation Manifold Models - Weight Coil and Spares kit Number of valves (kg) Terminal Box Assembly M8 Normally closed 0,13 QM8*28 QM800 DM8T2 Normally closed 2 0,31 QM8*28 QM8T200 DM8T3 Normally closed 3 0,5 QM8*28 QM8T0 DM8T Normally closed 0,60 QM8*28 QM8T00 M Normally open 0,13 QM8*28 QM800 *Insert voltage code, e.g. QM817328 for the low power 2V d.c. model. Electrical Details for M8 and M Valves Voltage Codes Availability V d.c. 160 M8, DM8 2 V d.c. (low power) 173 M8, DM8 2 V d.c. 7 M8, DM8 2 V 5060Hz 16 M8, DM8, M 8 V 5060Hz 165 M8, DM8, M 1100 V 55060Hz 166 M8, DM8, M 22020 V 5060Hz 167 M8, DM8, M Note: DC version of M available on request. Voltage Tolerances: d.c.: +10-% a.c.: +10-% Power: d.c.: 2 W (low power - 0,5 W on 2 V) InrushHold: a.c.: 2,5 VA (5 VA on 22020 V) 100% E.D. Inlet Orifice: 1,0 mm Operating Pressure: 0-10 bar Terminal Box: 3 pin plug with cable grip (DIN 3650 Form B) May be rotated 0 Cable Entry: Pg Solenoid Coil: May be rotated at 0 intervals Manual Override: Standard, turn 0 anti-clockwise to operate, turn clockwise to release Protection Class: IP65 (DIN 0050) Typical Response Times: ms on ms off Replacement Coil Assemblies The QM8*28 replacement coil assemblies are suitable for the following solenoid pilot operated models: M1761 M1762 M176 M1772 M177 M2013 M20 M2025 UM222 UM22162 UM22253 UM22263 UM2235 UM2236 UM2256 UM2266 UB22-MD UB2162-MD 1 1 - models 1 2 - models X 1 - models X 2 - models X - models EM5100 EM50 EM5000 5..021.02
M8, M Electrically Actuated Sub-base Mounted Valve M3 x 0,5 2 17 22 17 7 2.5 3 1 Model Number: M8 Type: 32 Normally closed 3 M8 1 M 2 3 1 Model Number: M Type: 32 Normally open 2 1 M8 3 M 10 5..021.03
M8, M Electrically Actuated Manifold Mounted Valve 3 M8 1 M 2 2 7 1 2 62 1 M8 3 M M x 0.7 8 6 3.2-5 20 Model Number: DM8T2 Type: 32 Normally closed Number of valves on manifold: 2 5..021.0
M8, M Electrically Actuated Manifold Mounted Valve 3 M8 1 M 2 2 7 1 2 2 1 M8 3 M M x 0.7 8 6 3.2-78 20 Model Number: DM8T3 Type: 32 Normally closed Number of valves on manifold: 3 10 5..021.05
M8, M Electrically Actuated Manifold Mounted Valve 3 M8 1 M 2 2 7 1 2 2 2 110 1 M8 3 M M x 0.7 8 6 3.2-102 20 Model Number: DM8T Type: 32 Normally closed Number of valves on manifold: 5..021.06
M8, M Options and Accessories Terminal Box with Lamp Indicator Voltage range Terminal box Maximum current consumption of indicator circuit -2 V d.c. MP211* 35 ma 0-1 V d.c. MP2 ma 80-1 V a.c.** MP2 ma 0-2 V a.c.** MP213 ma *Reduced light intensity at V. **Suitable for use at any frequency. Lamp arrangement MP211 1 blocking diode, 1 filament lamp Lamp arrangement MP2 and MP213 1 glow lamp, 1 resistor Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN MARTONAIR. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. 10 5..021.07
M, M1 Miniature, 22 mm normally closed and normally open models Sub-base mounted and manifold mounted 32 Poppet Valves Electrically Actuated Manual override as standard Encapsulated coils with very rapid fitting Technical Data Medium: Compressed air, filtered, lubricated and non-lubricated Operation: Poppet valve, directly actuated with spring return Mounting: Through-holes with thread in sub-base Port Size: Operating Pressure: 0-10 bar M, DM 0-7 bar M1, DM1 Flow (to CETOP RP50P): Conductance dm 3 sbar 0,25 M, DM Conductance dm 3 sbar 0,27 M1, DM1 Critical pressure ratio 0,3 M, DM Critical pressure ratio 0,117 M1, DM1 Cv 0,067 Cv 0,0-7 Operating Temperature: -5 C* to +50 C supply air +5 C to +50 C ambient *Consult our Technical Service for use below +2 C Materials Plastic encapsulated coil, moulded plastic manual override base, stainless steel armature tube and spring, aluminium sub-base, nitrile rubber seals. 3 Ordering Information To order, quote model number followed by voltage code shown in the tables overleaf, e.g. M167 for a normally closed low power model suitable for a 220V 50Hz electrical supply. Replacement coil and terminal box assemblies can also be supplied, quote required model number with Q prefix before the M and 28 suffix after the voltage code as shown in the table overleaf. For manifold models order the required number as indicated by the T suffix in the model number, e.g. off QM81028 for DM110T. 2 1 10 5..031.01
M, M1 General Information Model Operation Manifold Models - Weight Coil and Spares kit Number of valves (Kg) Terminal Box Assembly M Normally closed 0,1 QM8*28 QM800 DMT2 Normally closed 2 0,31 QM8*28 QM8T200 DMT3 Normally closed 3 0,5 QM8*28 QM8T0 DMT Normally closed 0,60 QM8*28 QM8T00 M1 Normally open 0,1 QM8*28 QM800 *Insert voltage code, e.g. QM817328 for the low power 2V d.c. model. Electrical Details for M and M1 Valves Voltage Codes Availability V d.c. 160 M, DM 2 V d.c. (low power) 173 M, DM 2 V d.c. 7 M, DM, M1, 2 V 5060Hz 16 M, DM, M1 8 V 5060Hz 165 M, DM, M1 1100 V 5060Hz 166 M, DM, M1 22020 V 5060Hz 167 M, DM, M1 Note: DC version of M1 available on request. Voltage Tolerances: d.c.: +10 % a.c.: +10 % Power: d.c.: 2 W (low power - 0,5 W on 2 V) InrushHold: a.c.: 2,5 VA (5 VA on 22020 V) 100%% E.D. Inlet Orifice: 1,0 mm Operating Pressure: 0-10 bar Terminal Box: Cable Entry: Solenoid Coil: Manual Override: 3 pin plug with cable grip (DIN 3650 Form B) May be rotated 0 Pg May be rotated at 0 intervals Standard, turn 0 anti-clockwise to operate, turn clockwise to release Protection Class: IP65 (DIN 0050) Typical Response Times: ms on ms off Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN MARTONAIR. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. 5..031.02
M, M1 Electrically Actuated Sub-base Mounted Valve M3 x 0,5 2 17 22 17 3 M8 1 M 7 2.5 3 1 Model Number: M Type: 32 Normally closed 2 3 1 Model Number: M1 Type: 32 Normally open 2 10 5..031.03
M, M1 Electrically Actuated Manifold Mounted Valve 3 M8 1 M 2 7 1 2 62 M x 0.7 8 6 3.2-5 20 Model Number: DMT2 Type: 32 Normally closed Number of valves on manifold: 2 5..031.0
M, M1 Electrically Actuated Manifold Mounted Valve 3 M8 1 M 2 7 1 2 2 M x 0.7 8 6 3.2-78 20 Model Number: DMT3 Type: 32 Normally closed Number of valves on manifold: 3 10 5..031.05
M, M1 Electrically Actuated Manifold Mounted Valve 3 M8 1 M 2 7 1 2 2 2 110 M x 0.7 8 6 3.2-102 20 Model Number: DMT Type: 32 Normally closed Number of valves on manifold: Options and Accessories Terminal Box with Lamp Indicator Voltage range Terminal box Maximum current consumption of indicator circuit -2V d.c. MP211* 35 ma 0-1V d.c. MP2 ma 80-1V a.c.** MP2 ma 0-2V a.c.** MP213 ma *Reduced light intensity at V. **Suitable for use at any frequency. Lamp arrangement MP211, 1 blocking diode, 1 filament lamp. Lamp arrangement MP2 and MP213, 1 glow lamp, 1 resistor. 5..031.06