Installation & Calibration Manual

Similar documents
Installation & Calibration

Installation & Calibration

INSTALLATION GUIDE Six Gauge Universal Digital Dash Panel Part Number: DP10002

I. SIM card preparation 3 II. Installation into a vehicle 3. III. Most common issues and their solutions 9 III. Attachments 10

Wired Real Time GPS Installation Instructions

INSTALLATION GUIDE Table of Contents

Nero 6600H/6601H. Installation Guide. Commercial Vehicle Productivity and Security. Antenna Configuration

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation

INSTALLATION GUIDE Chevrolet Digital Dash Panel Part Number: DP6002 YEAR SERIES:

INSTALLATION GUIDE Chevrolet Digital Dash Panel Part Number: DP6004 Year Series:

INSTALLATION GUIDE Chevrolet Digital Dash Panel Part Number: DP6002 Year Series:

INSTALLATION GUIDE Chevrolet Digital Dash Panel Part Number: DP6003 Year Series:

INSTALLATION GUIDE Chevrolet Impala/Caprice Digital Dash Panel Part Number: DP1208 Year Series: 1968

PHOENIX TACHOMETER WITH OLED DISPLAY

An ISO 9001:2008 Registered Company

Thank you for purchasing this instrument from Intellitronix. We value our customers!

INSTALLATION GUIDE Chevrolet Monte Carlo Dash Panel Part Number: DP9002 Year Series:

Interior Digital Load Scale 202-DDG-02. Installation and Operation Manual Please read carefully before installation

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

U L T I M A T E R A D A R / L A S E R D E F E N S E S Y S T E M

Part Number DP6003 Chevy Truck Digital Dash YEARS 67-72

DriveRight VSS Installation Guide

Toggle Button Kit. Installation Instructions

Onboard. Onboard RTU270 Installation Manual

Interior Digital Load Scale 202-DDG-01. Installation and Operation Manual Please read carefully before installation

OPERATOR S MANUAL 7(5 & ( 8&. $5.00 P/N REV.B

Toggle Button Kit. Installation Instructions MK5 / MK6 Golf, MK5 Jetta

Slope Detector IV Installation Instructions

Informational Distribution List:

The Power Systems Industry Experts. Installation Instructions. PT100 Stationary Generator Monitoring System

Service Manual Model S800 Smart Stand

TERMINATOR User Manual

Service Manual Model S400 and S500 Smart Stand

RD712 & RD712XL Remote Displays. Model 615 / 615XL Indicator User s Manual

C-IDLE750 Idle-Lock Anti-Theft 2018 RAM Contact InterMotive for additional vehicle applications.

Overview of operation modes

Crane Systems GREER COMPANY. LALT 1151L System for Lattice Cranes. Installation and Calibration Manual. 1 of 39

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

Idle Timer Controller - A-ITC520-A Ford E Series Ford F250 - F Ford F250 - F550 (*B-ITC520-A) F650/F750

INSTALLATION GUIDE Ford Mustang Digital Dash Panel Part Number: DP7009 Year Series:

Service Manual Model L1000 Smart Lift

AVH-2330NEX AVH-2300NEX AVH-1330NEX AVH-1300NEX

TL UNIVERSAL WIRING GUIDELINE TRCM - J jan18jh

AP500 FAULT FINDING NEW INSTALLATION

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

WARRANTY POLICY... 1 CONTACT INFORMATION... 2 OWNER STATISTICS... 3 TECHNICAL BULLETINS...

REC-11+ REMOTE RECEIVER UNIT

PN R CHEVY CAMARO w/reverse Two panel Sequential LED Taillight kit installation guide. Kit Contents:

CONTROLLER DIAGNOSTIC GUIDE

GTWY605 Fast Idle, Shift Interlock, I/O Chevy 610 Van - 6.0L and 6.6L Engines Contact InterMotive for additional vehicle applications.

IVTM Installation Manual

EC200 ELECTRONIC CONTROL SYSTEM

42 Series Step. Owner's Manual #842A. Equipped with a Permanent Magnet Motor. Table of Contents

Service Manual. Model L500 and L600 Smart Lift. WARNING: Cancer and Reproductive Harm - Form #1-144 Rev.

Manual - Inside Front Cover (Blank)

DP K9 Door Popper Installation Manual. Patented

User Manual SatStation Extreme Dock - Blue for IRIDIUM 9575

Throttle Sensitivity Booster

WARRANTY POLICY... 1 CONTACT INFORMATION... 2 OWNER STATISTICS... 3 TECHNICAL BULLETINS...

Installation and Operation Manual

Top quality Plug & weigh

TL UNIVERSAL WIRING PROCEDURE

V300S SERIES OWNER S MANUAL

Guardian GRD502-A Adapter Matrix

Interior Digital Load Scale 202-DDG-01. Installation and Operation Manual Please read carefully before installation

Security and Keyless Entry Installation Guide ca 1051

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

ATTENTION. Custom Dynamics UTV Turn Signal Kit Installation Instructions

CLS-420 Wired Version Cargo Lift Scale

An ISO 9001:2008 Registered Company

INSTALLATION GUIDE Multi-Gauge Set with sending units Part Number: M 9999

with lcd display 12-42v

Installation Instructions for VTU

Ford 6.7L Installation of the Guardian Safety System

INSTALLATION INSTRUCTIONS

Volkswagen Information System. Introduction

MXL Pista / MXL Strada PLUG & PLAY KIT FOR SUZUKI GSX R

AVH-601EX AVH-600EX AVH-501EX AVH-500EX

Assembly instructions WAES

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

VoloMOD Full Feature Installation (Turn signals

CLS-420 Wired Version Cargo Lift Scale

Remote Keyless Entry Installation Guide ca 2051

COMMANDO REMOTE CONTROL ENGINE STARTER. Limited Warranty Statement MADE IN THE U.S.A. IMPORTANT KEEP YOUR INVOICE WITH THIS WARRANTY STATEMENT!

SPEED SHIFT/TWO-STEP MODULE INSTALLATION MANUAL

INSTALLATION GUIDE AV7900 Dual Multimedia Headrest Replacement System

Guardian Personal Mobility Lift Interlock GRD701-AR ( Dodge Sprinter) Installation Instructions

INSTALLATION INSTRUCTIONS

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Optional Extras 1. Part #AT7107A Privacy Handset 2. Part # HMN4058A Potato Mic.

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

High Idle Kit Dodge Cummins (24 valve) Dodge Cummins (with APPS on motor) PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION

SKY-WEIGH HELICOPTER CARGO HOOK LOAD MONITORING SYSTEM. User Guide Quality Industrial Weighing and Force Measurement Equipment

INSTALLATION GUIDE Car Show Dual DVD Headrest Replacement System

SP Switch Programmable Switch Panel Power System. Parts Included

ROADRELAY 5 Installation Guide

Signet Pressure Transmitter

General Applicability: KIA Sorento. Issues Current Kit does not allow for CAN DATA remote access

Service Procedure Note Note Note

CA-210 Installation Instructions

Transcription:

Installation & Calibration Manual SkidWeigh ED2-Print Series On-board Lift Truck Check Weighing Scale With Accumulative Load Total ED2-Print V1600

General Installation Guide This SkidWeigh ED2-Print system version V1600, installation & calibration guide describes how to install, calibrate, test and use your lift truck onboard check weighing scale. Following the instructions in this guide will enable you to get your system operating quickly and with ease. In the event that you require additional assistance, please contact technical support below. Integrated Visual Data Technology Inc. 3439 Whilabout Terrace Oakville, Ontario L6L 0A7 Phone: 905-469-0985 Email: support@sidweight.com Web: www.skidweigh.com Safety Always disconnect the vehicle battery before installing SkidWeigh systems. Make sure that the digital indicator, pressure transducer and any other associated cables are securely mounted and do not impede any of the vehicle s controls. Use care when routing the component cables and where they will be protected. Use commonly accepted install practices for after market industrial vehicle electronic devices. The installation of SkidWeigh systems should only be performed by an acknowledged lift truck technician or other with competent knowledge of electrical and hydraulic systems. Here are two acceptable methods of making a wire connections: 1.Soldering your connections (recommended) 2.Crimp connectors (with the use of the proper crimping tool) Regardless of the method you choose, ensure that the connection is mechanically sound and properly insulated. Use high quality electrical tape and shrink tubing where necessary. This product is connected directly to the vehicle s ignition switch, 12 to 55 VDC. There is no On-Off switch on the digital indicator. Electro-Magnetic Compatibility CE conformity to EC directive 89/336 (EMC) by application of harmonized standards: Interference stability EN 61000-6-2 and EN 61326-1 interference emit EN 61000-6-3, EN 61326-1 for the pressure transducer.

SkidWeigh ED2-Print Version 1600 Our policy is one of continuous improvement and the information in this document is subject to change without notice. Check that software version displayed on the LED display is reflective of this manual. Overview of Components The standard SkidWeigh ED2-Print check weighing system kit consist of two main components: * Digital indicator with external overload audio warning, wiring harness and anti-vibration mounting bracket. * Hydraulic pressure transducer with 3 wire connection cable. * Installation & calibration manual as well as quick reference operator usage instructions. Operational Principal The SkidWeigh ED2-Print operational principal is based on mounting a pressure transducer into the vehicles hydraulic lifting circuit between the lift control valve and lifting cylinder(s). Upon usage proprietary software will automatically activate the weighing cycle algorithm when a skid load is lifted just above the ground. The increase in pressure is converted through an electronic signal at the sample rate of 16000 readings per session which is then converted into a load weight reading. Pressure Transducer T-Piece Installing the Pressure Transducer The pressure transducer must be installed in the hydraulic lift line between the lift control valve and lift cylinder(s). In some cases you can install the pressure transducer in the flow divider, drilling and tapping for 1/4-18 NPT male in spare plug or in the body of the flow divider. Also, you can drill and tap on any larger elbow that might be available in the hydraulic lift circuit found in vehicles with larger hoses to accommodate larger vehicle lifting capacities. Flow Divider Flow Divider

Pressure Transducer Installation Precautions Before installation of the pressure transducer the hydraulic lift circuit must be pressure free. There are two ways to do that: 1. Place the forks on the ground at their lowest position and make sure the hydraulic system pressure is completely free by tilting the mast forward. The chain(s) should be slack. 2. Lift the forks and position them on the top of a supporting fixture. Start lowering the lift cylinder into its lowest position. Ensure that the chain(s) is slack. 3 Wire Pressure Transducer Cable Make sure that that pressure transducer when installed will not touch or obstruct any assembly or moving parts during operation. The pressure transducer has a 1/4-18 NPT male thread. Use thread seal to ensure tight fit. 1/4-18 NPT male thread Selecting the Mounting Location for the Digital Indicator Use the anti vibration mounting bracket and fasten the digital indicator on the vehicle dashboard, side rail, or over head guard, preferably on the right hand side. There are many examples of mounting locations that will depend on the vehicle model. Each SkidWeigh ED2 kit comes complete with flat universal mounting brackets designed for mounting on the overhead guard. Choose the correct location and make sure that: 1. The Indicator is visible and within reach of the operator. 2. The location does not impede the operator safety entering the vehicle or obstruct operational sight lines Mounting Bracket

Electrical Connections - Orange Wire (+) Ignition switch on position (12 to 55 VDC) - Brown Wire (-) Battery negative - Red Wire, connect to RED wire of the pressure transducer cable - Black Wire, connect to BLACK wire of the pressure transducer cable - White Wire, connect to WHITE wire of the pressure transducer cable Printer cable with RS232 port and power supply Pressure transducer cable Pressure transducer 3 wires cable must be connected to the digital indicator cable Electrical power short circuit protection - All of the SkidWeigh systems are internally short circuit protected with resettable fuse. There is no need to install external inline fuse in orange wire connected to the ignition switch. - Automotive 60 V load dump protection - Reversal power supply protection Pressure Transducer (3 wires) - Red Wire, connect to the RED wire of the pressure transducer cable - Black Wire, connect to BLACK wire of the pressure transducer cable - White Wire, connect to WHITE wire of the pressure transducer cable System Power Supply (2 wires) - Orange Wire (+) Ignition switch - Brown Wire (-) Battery negative Blue, Green and Blue Wires (Application for Optional Devices)

Quick Test System Check Note: The following Quick Test allows the installer to ensure that the both the electrical connections and the installation of the pressure transducer have been performed correctly. Also note the SkidWeigh system is not to be calibrated at this stage. After you have connected electrical power and the pressure transducer cable you can check system operation following these steps. 1. Lower the forks to the ground. 2. Turn on the ignition switch. -The digital LED display will be activated showing the software version and serial number. -The number 8 will be shown on the LED display above the Mode symbol. 3. Lift the forks above the ground with a load to activate the weighing cycle. -Mode 8 will disappear and within a few seconds a load weight will show on the LED display. If the system responds as per the above test the electrical connections and pressure transducer are installed correctly. The load weight will not be accurate as the system has not been calibrated at this point. Hydraulic Accumulators The following applies to lift trucks equipped with hydraulic accumulators. Note: Before installation please ensure that the system was ordered specifically for trucks equipped with hydraulic accumulators. If not please contact technical support for confirmation and or a system with the correct software configuration. Hydraulic Pressure Transducer Mounting Location

Calibration Procedure The SkidWeigh ED2-Print calibration cycle is a simple and automatic process that is completed by lifting both empty and loaded forks, and or attachment, and programming the weights into the system. The entire process takes approximately 3 minutes and will require the following to be completed in advance. 1.The paper clip supplied with the system or like. 2. A pre-weighed load in order to set an accurate programming standard into the system. Use an existing floor scale to verify the actual weight or a trusted accurate shipping label. For best results try to secure a load test weight that is 30-50% of the maximum lifting capacity. Note: The system can show the load weight in either pounds or kilograms, but not simultaneously. Therefore, calibrate in the preferred measurement unit. Two Button Calibration Mode Indicator Mode Toggle Switch Digit Toggle Switch Zeroing the Empty Forks/Attachment 1. Lower the empty forks to the ground. There should be no hydraulic pressure in the hydraulic lift circuit. 2. Turn the ignition switch to the on position to apply power to the system. The LED indicator will display the software version and serial number briefly before defaulting to 8 above the Mode Indicator.

" " " 3. To begin the calibration process press the M button, using a paper clip and hold for few seconds. Eventually the 8 will change to 0 above the mode indicator. System is ready for automatic zeroing. 4. With the indicator showing 0 lift he empty forks approximately 2-4 off the ground. With the vehicle stationary do not manipulate the tilt, side shift, or fourth lever function during the lifting process. Activate as you would normally during operation of the vehicle. 5. Within a few seconds of lifting the forks, the LED display will go blank and the digit 1 will show above the Mode Indicator. On the far right side of the display a default 0 will be shown if the system is being calibrated for the first time. If a recalibration is being performed then the digit programmed from the prior session will show instead. Automatic Zeroing is Complete. Calibrating the System with a Load Weight 6. With the LED display showing 0 at the far right it is time to enter the known weight secured prior to the calibration process. Using the paper clip enter that weight beginning with Mode 1 through 5, for weights in excess of 9999 lb./kg. If the weight is 9999 or below enter 0 for Mode 5. See the example below. (In our example we will use the known load weight of 4000) First least significant digit 0 Second least significant digit 0 Third least significant digit 0 Forth least significant digit 4 Fifth least enter 0 " "

7. With the system at Mode 5, after entering all digits, drive into the secured palleted load. Once the loads is secure on the lift truck make sure that all pressure is out of the hydraulic system by lowering the forks till the lift chains show slack. 8. Using the paper clip press the M button to advance to Mode 6. 9. Lift the known weight 2-4 off the ground similar to the zeroing process. With the vehicle stationary do not manipulate the tilt, side shift, or fourth lever function during the lifting process. Activate lift control lever and lift load as you would normally during operation of the vehicle. After few seconds the LED display will show calibrated load weight. System is now calibrated. Entering Overload Warning (ED2-Print-SM SkidWeigh Series) If the SkidWeigh ED2-Print-SM Series system utilizes the SM (Overload) function) than the system will automatically default to MODE 7 when the loaded forks are lowered to the ground. Using the M and Up Arrow buttons enter the overload weight value for your application similar to the process when calibrating the system with a load weight except the MODE 7 digit remains throughout this operation. Once the last digit has been entered MODE 7 will disappear. The overload weight value is now successfully stored into the system memory. Example: Below is an example of a desired overload weight of 4850. As per the calibration process for value 9999 or less enter 0 for the 5th digit. Mode Digit 5 Digit 4 Digit 3 Digit 2 Digit 1 7 0 4 8 5 0 System is calibrated for both weight and overload warning

Operator Usage Guide ED2 SkidWeigh Series Accumulative Load Weight Total and Print Load Add Button Onboard Printer ED2 SkidWeigh Series Turn on ignition switch With LED display will show software version for the moment and mode will indicate number 8 which is the starting point to initiate load weight cycle (Loaded forks must be lowered to ground, no pressure in lift hydraulic circuit for the system to show Mode 8) Insert the forks into the pallet or product to be weighed Lower the loaded forks to the ground. With LED display showing number 8 in Mode, lift load just above the ground Do not manipulate the tilt, side shifter or move vehicle during the weighing cycle Lift the load approx. 2 off the ground using the hydraulic lift lever same as during normal usage. Do not use lift lever by lifting load slowly. Within few seconds load weight will be indicated on LED display. Note: During the normal vehicle usage the LED display might show 0 or some other load weight which is due to the hydraulic spikes. To initiate a load weighing cycle you must lower loaded forks to the ground and LED must show number 8 in Mode window. PAGE!1 OF!2

Accumulative Load Weight Function With LED display showing load weight, press Black button to start accumulating loads With last load weight lifted and shown on LED display by pressing RED button all individual loads and total load weight will be shown. If the onboard Bluetooth printer is used than all individual load weights and total will be printed Overload Indication The ED2SkidWeigh series with optional overload warning will automatically show on LED display the overload load value and display will flash. The audio / visual warning will be activated to warn the operator of such condition. To stop the overload visual / audio overload warning operator must lower the load to the ground. Two Independent Weighing Channels Two Weighing Channels Switch Channel 1 (showing Mode 8 on LED display) Channel 2 (showing Mode 82 on LED display) Use external mounted switch to utilize the two independent weighing channels function. Example: Standard forks and long forks weighing application Note: Weighing channel one is shown as a Mode 8 and second is shown as Mode 82. Electric Pallet Truck Weighing Function (ED2-EP Skidweigh Series) Turn on power switch (ED2-EP only). Insert forks into the load and lower it to the ground. Power On / Off Switch The LED display must show Mode 8. Activate and hold vehicle lift control until lifting cylinder is automatically stopped Weighing cycle will start, the LED display will go blank for the moment and load weight will be shown. As soon the load weight is shown the lift motor motion control is disabled Lift cylinder motion control will go back to normal operational mode Note: During normal operation where weighing function is not required turn the indicator power switch ON /OFF to off position. (The ED2E-EP system will be turned off) INTEGRATED VISUAL DATA TECHNOLOGY INC. 3439 Whilabout Terrace, Oakville, Ontario, L6L 0A7 Canada Phone: 905-469-0985 Fax: 905-825-9494 skidweigh.com PAGE! 2 OF! 2 VER. FLS3-2