General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

Similar documents
General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

General technical data: CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL. product brand name

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

General technical data. Ambient conditions

CONTACTOR, AC KW/400 V, DC 24 V, 3-POLE, SIZE S0, SCREW CONNECTION. General details: Main circuit: Product brand name. Size of the contactor

3RT2028-1BB40. at rectangular impulse at DC 10g / 5 ms, 7,5g / 10 ms at sine pulse at DC 15g / 5 ms, 10g / 10 ms

3RV2011-1AA10 CIRCUIT-BREAKER SCREW CONNECTION 1.6A

3RT14 Contactors with 3 Main Contacts

B Mini Contactor V Hz

Mini contactors B6, BC6 with 3 pole

Protection Equipment

Application Mini Contactors for Motors and Resistive Loads

Thermal Overload Relays - WEG RW Series, 2 Pole

MS General Information Extended Product Type: MS

AF40... AF96 3-pole contactors Technical data

Technical specifications

BC Mini Contactor VDC

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Industrial Contactors CTX 3 3P 185A - 800A

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

SIRIUS 3RU2 Thermal Overload Relays

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

SENTRON Switching and Protection Devices Switch Disconnectors

Protection Equipment. 5/2 Introduction

AE 9... AE 40 Contactors NE... Contactor Relays

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Protective Devices: Circuit-Breakers 1 )

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Meta Solution. Contactors and Overload relays

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

ASL09..S 3-pole Contactors - Spring Terminals

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

3VU13, 3VU16 Circuit-Breakers

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Description. Positive safety relays

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

DEVICE STATE/BYPASSED FAILURE OVERLOAD

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Application Mini Contactors for Motors and Resistive Loads

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

3SE3 1 SIGUARD Position Switches

Technical Information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

TAE pole Contactors

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase

Thermal overload relay TF140DU and TF140DU-V1000

Technical data for manual motor starters Type MS325

Micro Contactor MA Series

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

General_technical_data Series

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

W Datasheet: DIN Rail Contactors, series AMPARO

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

DIN EN UL 508 / CSA 3RF A A 0 2

Solid State Relays, 3-phase

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

Thermal overload relay TF65 and TF96

Special Purpose Fuses

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

BETA Switching Switches and Light Indicators

Electronic overload relay EF65, EF96 and EF146

Electronic overload relays EF205 and EF370

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

Bulletin 193-T1 Bimetallic Overload Relays

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

3TM Vacuum Contactors

Short form catalogue. Motor protection & control

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

D509E. Manual Motor - Starters

Miniature Circuit Breaker

Manual Motor Starters. Meta-MEC

SIGUARD Safety Systems Safety Integrated

DC/DC converters - MINI-PS DC/ 5-15DC/

4 - Miniature controls

General_technical_data Series

Transcription:

Data sheet CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL product brand name Product designation SIRIUS 3RT2 contactor General technical data: Size of contactor S00 Product expansion function module for communication No Auxiliary switch Yes Insulation voltage Rated value 690 V Surge voltage resistance Rated value 6 kv maximum permissible voltage for safe isolation 400 V between coil and main contacts acc. to EN 60947-1 Protection class IP on the front IP20 of the terminal IP20 Degree of pollution 3 Shock resistance at rectangular impulse at AC 7,3g / 5 ms, 4,7g / 10 ms Page 1/10 14.11.2015 Copyright Siemens AG

with sine pulse at AC 11,4g / 5 ms, 7,3g / 10 ms Mechanical service life (switching cycles) of the contactor typical 30 000 000 of the contactor with added electronicscompatible auxiliary switch block typical 5 000 000 of the contactor with added auxiliary switch 10 000 000 block typical Ambient conditions: Installation altitude at height above sea level 2 000 m maximum Ambient temperature during operation -25... +60 C during storage -55... +80 C Main circuit: Number of NO contacts for main contacts 3 Number of NC contacts for main contacts 0 Operating voltage at AC-3 Rated value maximum 690 V Operating current at AC-1 at 400 V at ambient temperature 40 C Rated value 22 A at AC-1 up to 690 V at ambient temperature 40 C Rated value 22 A at ambient temperature 60 C Rated value 20 A at AC-2 at 400 V Rated value 12 A at AC-3 at 400 V Rated value 12 A at 500 V Rated value 9.2 A at 690 V Rated value 6.7 A Connectable conductor cross-section in main circuit at AC-1 at 60 C minimum permissible 2.5 mm² at 40 C minimum permissible 4 mm² Operating current at 1 current path at DC-1 at 24 V Rated value 20 A at 110 V Rated value 2.1 A at 220 V Rated value 0.8 A at 440 V Rated value 0.6 A at 600 V Rated value 0.6 A with 2 current paths in series at DC-1 Page 2/10 14.11.2015 Copyright Siemens AG

at 24 V Rated value 20 A at 110 V Rated value 12 A at 220 V Rated value 1.6 A at 440 V Rated value 0.8 A at 600 V Rated value 0.7 A with 3 current paths in series at DC-1 at 24 V Rated value 20 A at 110 V Rated value 20 A at 220 V Rated value 20 A at 440 V Rated value 1.3 A at 600 V Rated value 1 A Operating current at 1 current path at DC-3 at DC-5 at 24 V Rated value 20 A at 110 V Rated value 0.1 A with 2 current paths in series at DC-3 at DC-5 at 110 V Rated value 0.35 A at 24 V Rated value 20 A with 3 current paths in series at DC-3 at DC-5 at 110 V Rated value 20 A at 220 V Rated value 1.5 A at 24 V Rated value 20 A at 440 V Rated value 0.2 A at 600 V Rated value 0.2 A Operating power at AC-1 at 230 V Rated value 7.5 kw at 230 V at 60 C Rated value 7.5 kw at 400 V Rated value 13 kw at 400 V at 60 C Rated value 13 kw at 690 V Rated value 22 kw at 690 V at 60 C Rated value 22 kw at AC-2 at 400 V Rated value 5.5 kw at AC-3 at 230 V Rated value 3 kw at 400 V Rated value 5.5 kw at 690 V Rated value 5.5 kw Thermal short-time current limited to 10 s 90 A Active power loss at AC-3 at 400 V for rated value of 1.2 W the operating current per conductor No-load switching frequency Page 3/10 14.11.2015 Copyright Siemens AG

at AC 10 000 1/h Operating frequency at AC-1 maximum 1 000 1/h at AC-2 maximum 750 1/h at AC-3 maximum 750 1/h at AC-4 maximum 250 1/h Control circuit/ Control: Type of voltage of the control supply voltage AC Control supply voltage at AC at 50 Hz Rated value 110 V at 60 Hz Rated value 120 V Operating range factor control supply voltage rated value of the magnet coil at AC at 50 Hz 0.8... 1.1 at 60 Hz 0.85... 1.1 Apparent pick-up power of the magnet coil at AC at 50 Hz 37 V A at 60 Hz 33 V A Inductive power factor with closing power of the coil at 50 Hz 0.8 at 60 Hz 0.75 Apparent holding power of the magnet coil at AC at 50 Hz 5.7 V A at 60 Hz 4.4 V A Inductive power factor with the holding power of the coil at 50 Hz 0.25 at 60 Hz 0.25 Closing delay at AC 8... 33 ms Opening delay at AC 4... 15 ms Arcing time 10... 15 ms Residual current of the electronics for control with signal <0> at AC at 230 V maximum permissible 4 ma at DC at 24 V maximum permissible 10 ma Auxiliary circuit: Number of NC contacts for auxiliary contacts instantaneous contact 1 Number of NO contacts Page 4/10 14.11.2015 Copyright Siemens AG

for auxiliary contacts instantaneous contact 0 Operating current at AC-12 maximum 10 A Operating current at AC-15 at 230 V Rated value 10 A at 400 V Rated value 3 A at 500 V Rated value 2 A at 690 V Rated value 1 A Operating current at DC-12 at 24 V Rated value 10 A at 48 V Rated value 6 A at 60 V Rated value 6 A at 110 V Rated value 3 A at 125 V Rated value 2 A at 220 V Rated value 1 A at 600 V Rated value 0.15 A Operating current at DC-13 at 24 V Rated value 10 A at 48 V Rated value 2 A at 60 V Rated value 2 A at 110 V Rated value 1 A at 125 V Rated value 0.9 A at 220 V Rated value 0.3 A at 600 V Rated value 0.1 A Contact reliability of the auxiliary contacts 1 faulty switching per 100 million (17 V, 1 ma) UL/CSA ratings: Full-load current (FLA) for three-phase AC motor at 480 V Rated value 11 A at 600 V Rated value 11 A yielded mechanical performance [hp] for single-phase AC motor at 110/120 V Rated value 0.5 hp at 230 V Rated value 2 hp for three-phase AC motor at 200/208 V Rated value 3 hp at 220/230 V Rated value 3 hp at 460/480 V Rated value 7.5 hp at 575/600 V Rated value 10 hp Contact rating of the auxiliary contacts acc. to UL A600 / Q600 Short-circuit protection Design of the fuse link Page 5/10 14.11.2015 Copyright Siemens AG

for short-circuit protection of the main circuit with type of assignment 1 required gl/gg NH 3NA, DIAZED 5SB, NEOZED 5SE: 50 A with type of assignment 2 required gl/gg LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 25 A for short-circuit protection of the auxiliary switch fuse gl/gg: 10 A required Installation/ mounting/ dimensions: mounting position +/-180 rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5 on vertical mounting surface Mounting type screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 Side-by-side mounting Yes Height 58 mm Width 45 mm Depth 73 mm Required spacing with side-by-side mounting forwards 0 mm Backwards 0 mm upwards 0 mm downwards 0 mm at the side 0 mm for grounded parts forwards 0 mm Backwards 0 mm upwards 0 mm at the side 6 mm downwards 0 mm for live parts forwards 0 mm Backwards 0 mm upwards 0 mm downwards 0 mm at the side 6 mm Connections/ Terminals: Type of electrical connection for main current circuit screw-type terminals for auxiliary and control current circuit screw-type terminals Type of connectable conductor cross-section for main contacts single or multi-stranded 2x (0,5... 1,5 mm²), 2x (0,75... 2,5 mm²), 2x 4 mm² Page 6/10 14.11.2015 Copyright Siemens AG

finely stranded with core end processing 2x (0.5... 1.5 mm²), 2x (0.75... 2.5 mm²) for AWG conductors for main contacts 2x (20... 16), 2x (18... 14), 2x 12 Type of connectable conductor cross-section for auxiliary contacts single or multi-stranded 2x (0,5... 1,5 mm²), 2x (0,75... 2,5 mm²), 2x 4 mm² finely stranded with core end processing 2x (0.5... 1.5 mm²), 2x (0.75... 2.5 mm²) for AWG conductors for auxiliary contacts 2x (20... 16), 2x (18... 14), 2x 12 Safety related data: B10 value with high demand rate acc. to SN 31920 1 000 000 Proportion of dangerous failures with low demand rate acc. to SN 31920 40 % with high demand rate acc. to SN 31920 73 % Product function Mirror contact acc. to IEC 60947-4-1 Yes T1 value for proof test interval or service life acc. to 20 y IEC 61508 Certificates/ approvals: Page 7/10 14.11.2015 Copyright Siemens AG

General Product Approval Functional Safety/Safety of Machinery Baumusterbescheini gung Declaration of Conformity Test Certificates spezielle Prüfbescheinigunge n Typprüfbescheinigu ng/werkszeugnis Shipping Approval Shipping Approval other Umweltbestätigung Bestätigungen other Further information Information- and Downloadcenter (Catalogs, Brochures, ) http://www.siemens.com/industrial-controls/catalogs Industry Mall (Online ordering system) http://www.siemens.com/industrymall Cax online generator http://support.automation.siemens.com/ww/caxorder/default.aspx?lang=en&mlfb=3rt20171ak62 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3rt20171ak62 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros,...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3rt20171ak62&lang=en Page 8/10 14.11.2015 Copyright Siemens AG

45 73 35 5 57.5 50 29.8 5 3.8 1.2 5 Page 9/10 14.11.2015 Copyright Siemens AG

-Q A1 1 /L1 3 /L2 5 /L3 21 A2 2 /T1 4 /T2 6 /T3 22 last modified: 29.09.2015 Page 10/10 14.11.2015 Copyright Siemens AG