INSTRUCTION MANUAL FOR SAMSON GAMMA UNITS, TYPES: GAMMA 10, -20, -30, -40, -50, -60, -70, -90, -100

Similar documents
INSTRUCTION MANUAL FOR SAMSON LIQUID RING PUMPS, TYPES: KS500, KS510, KS625, KS725, KS910, KS1025

Installation and operating manual

Swing Piston Compressors and Vacuum Pumps

THE STRONGEST MUD VACUUM CLEANER IN THE WORLD OFFSHORE VACLEAN

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Instruction Manual. Unique Single Seat Valve - Manually Operated ESE00523-EN Original manual TD TD

RHD OFFSET SERIES 160/190/225 Flail Mowers

Instruction Manual. Unique Single Seat Valve - Manually Operated ESE00523-EN Original manual TD TD

Instruction Manual. Magnetic Mixer MM UltraPure ESE01696-EN Original manual TD

operating instruction

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Pneumatic grease pump 50:1 and grease supply system

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Mounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner

Pressure relief valve

PALLET TRUCK PAINTED OPERATING INSTRUCTIONS MAINTENANCE MANUAL PARTS CATALOGUE DECLARATIONS OF CONFORMITY

Operating manual Separator

80 Litre Suction Oil Drainer With Inspection Chamber

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Angle seat valve with diaphragm actuator VZXA-...-M

X.. Series Helical and Bevel-Helical Gear Units

Turbocharger / TPS-H Original assembly instructions English

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

Angle seat valve with piston actuator VZXA-...-K

Micro Diaphragm Gas Sampling Pumps

User manual Pipe notcher Type: AL 1-2E

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Certificate of Incorporation (Typical)

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Instruction Manual. LKAP Air-Operated Valve ESE01993-EN Original manual

Instruction Manual. Unique 7000 Series Aseptic - Manually Operated ESE02421-ENUS Original manual

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Operating Instructions Garlock Butterfly Valves DN : mm / 2-24

Installation and Service Instructions (Translation of the Original Instructions) SV120. C _EN 11/2009 Rev.0

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

HIGH LIFTER MANUAL, LAKERET

Support T10552 T10595 T40386

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

Declaration of Conformity as per Directive 97/23/EC

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Instruction Manual. Unique Single Seat Valve - Long Stroke ESE00222-EN

Micro Diaphragm Gas Sampling Pumps

Mounting and Operating Instructions EB EN. Type 3271 Pneumatic Actuator. Actuator area: 1000 cm². Translation of original instructions

A408 GB. Pneumatic oil and diesel pumps 1:1

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1

Turbocharger / A100-L Original assembly instructions English

Instruction Manual. Unique RV-P, pneumatic regulating valve ESE02801-EN Original manual

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Unique 7000 Series Valve - Standard and Reverse Acting

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Alfa Laval Toftejorg Rotary Spray Heads MultiMidget & MultiMagnum

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Mounting and Operating Instructions EB 8052 EN. Type 3251 Valve

NUFORS-DC VALVE SERVICE

Mounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm²

Operation & Technical Manual. Model: Ground Test Motor

Instruction Manual. Unique Single Seat Valve - Tank Outlet ESE00364-EN Original manual TD _2

Turbocharger / TPL-B Original assembly instructions English

Oil-free piston compressors KK and piston vacuum pumps KV

Important instructions

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

EU DECLARATION CONFORMANCE

A brief guide for identification of non-compliant construction machinery. Is this. Compactor / Roller compliant with European legislation?

Service - Safety Manual

INSTRUCTION MANUAL: Industrial Series Piston Air Compressor. Model Number: V Part Number: L001128KNA

These installation and maintenance instructions must be read in full and completely understood before the installation!

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

OPERATING AND MAINTENANCE INSTRUCTIONS HYDRAULIC ELECTRICAL PUMPS HAM (Manual control) HAE (Electrical control)

Instruction Manual. SBV Sanitary Ball Valve ESE01782-EN Original manual TD

AK / AV 4 & 5 SERIES Metallic Vertical Centrifugal Pumps Installation and Maintenance Instructions

VPI45..Q with pressure test points. Combi valves, PN 25

Translation of the Original operating instructions Lifting device Z 70 /...

Instruction and Maintenance Manual

DIAPHRAGM LIQUID PUMP NF 1.30

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Printed: Doc-Nr: PUB / / 000 / 00

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Vacuum Pumps PM80T MORO USA, INC. Use and maintenance manual. ST. LOUIS, MO OFFICE PO Box 632 UNION, MO (866) Fax: (636)

Spare parts list Return line filter RFM with 2-hole attachment

AGRO. Manual Bucket elevator T53/T54/T55 Version

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Mod: KLD6-12/35XLAS-N

Spare Parts List Return line filter RF

Mounting and Operating Instructions

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS RIGHT ANGLE FILTER Original Manual EN (0) 2019/02

Hydraulic Impact Wrench Type

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS

Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar

Compensation unit AGE-XY 50-80

Transcription:

TRUCKS FOOD OFFSHORE FISH SAMSON LIQUID RING VACUUM PUMPS INSTRUCTION MANUAL FOR SAMSON GAMMA UNITS, TYPES: GAMMA 10, -20, -30, -40, -50, -60, -70, -90, -100 DOC3700C INDUSTRY GAMMA UNITS

2

CONTENTS 1 Introduction...4 1.1 Declaration of conformity... 4 1.2 Explanation of warning symbols... 5 1.3 Marking and identification... 5 1.4 Purpose of use... 5 2 Technical data...6 2.1 Available models... 6 2.2 Dimensions [mm]... 6 2.3 Storage conditions... 9 2.4 Handling and transport... 9 2.5 Removal and disposal... 10 3 Installation and start-up...11 3.1 Installation requirements... 11 3.1.1 Anchoring... 11 3.1.2 Electrical installation... 11 3.1.3 Service liquid supply... 11 3.2 Prior to start-up... 12 3.2.1 Activating the grease cartridges... 12 3.2.2 Direction of rotation... 12 3.2.3 Vacuum limiter... 12 3.2.4 Serial connection... 12 3.3 Start-Up... 12 4 Service, maintenance and inspection intervals...13 4.1 Maintenance... 13 4.1.1 Transmission... 13 4.1.2 Lubrication of pump bearings... 13 4.1.3 Lubrication of motor bearings... 13 4.1.4 4-way valve (if equipped)... 13 4.1.5 Liquid separator (if equipped)... 13 5 Spare parts...14 5.1 How to order... 14 GAMMA units 3

1 INTRODUCTION 1.1 Declaration of conformity Declaration of Conformity Annex IIA Samson Pumps A/S Petersmindevej 21 DK-8800 Viborg Hereby declares that products: Gamma 10, -20, -30, -40, -50, -60, -70, -90, -100 Conforms to directive: Machinery Directive 2006/42/EC Low Voltage Directive 2014/35/EU I hereby declare, that the products are in conformity with the following harmonized standards: DS/EN ISO 12100:2011 DS/EN 1012-2 + A1:2009 Safety of machinery - General principles for design - Risk assessment and risk reduction Compressors and Pumps - Safety requirements - Part 2: Vacuum pumps The standards above only apply to the extent that it is relevant for the purpose of the products. The product must not be used before the complete system, which it must be incorporated in, has been conformity assessed and found to comply with all relevant health and safety requirements of 2006/42/EC and other relevant directives. The product must be included in the overall risk assessment. Viborg, 09.03.2017 Kelvin Storm Jensen R&D Manager Samson Pumps A/S DOC4012B Email info@samson-pumps.com Samson Pumps A/S Petersmindevej 21 Web www.samson-pumps.com Phone +45 87 50 95 70 DK-8800 Viborg 4

1.2 Explanation of warning symbols Important technical and safety instructions is showed by symbols. If instructions are not performed correctly, it may lead to personnel injury or incorrect function of the Gamma unit. To be used with all safety instructions that must be followed. A failure to follow the instructions may result in injury and/or incorrect machine operation. This symbol refers to hazardous situations involving electricity. A failure to observe the safety warnings may result in injury or death. The work may only be carried out by trained professionals who are familiar with the equipment. 1.3 Marking and identification The unit is equipped with an identification plate that is shown below. It contains important information, which can be useful in case of troubleshooting, service, weight etc. CE CONFORMITY MARK ORDER CONFIRMATION NUMBER / A NUMBER / WEIGHT MANUFACTURING DATE / SERIAL NUMBER TYPE OF UNIT Configuration example: G 50 C2 G Y 1 N N N S Z Type: GAMMA Model: 50 Transmission: Liquid separator: Vacuum limiter: Temp. control: 4-way valve: Actuator: Pipe connection: Unit type: Not in use: C2 G Y S N N N S Z Location of ID plate 1.4 Purpose of use DOC106912_5 GAMMA series are built with V-belt transmission. It provides a simple and economical possibility of adjusting the pump speed/ number of rotations, so that the air flow and power consumption will be optimized. The basic module consists of pump, electric motor and transmission, ready DOC106912_5 for operation. Additionally, the unit can be configured with the following additional modules: Liquid separator Cooling module based on partial recirculation of service liquid Cooling module based on a heat exchanger Cooling unit with air cooler 4-way valve for vacuum- and pressure operation (See liquid separator manual) (See liquid separator manual) (See liquid separator manual) (See liquid separator manual) (See 4-way valve manual) For further information regarding the additional modules, please study our website www.samson-pumps.com or contact our sales department. GAMMA units 5

2 TECHNICAL DATA 2.1 Available models GAMMA unit models Applicable with pump types Weight based on motor [kw]: GAMMA 10 KE180 or KE200 5,5 GAMMA 20 KE225 or KE300 7,5 GAMMA 30 KL350 or KL400 11 GAMMA 40 KL430 or KL500 15 GAMMA 50 KS500 or KS510 18 GAMMA 60 KS625 or KS725 22 GAMMA 70 KS910 or KS1025 30 GAMMA 90 KM2200 75 GAMMA 100 KM2700 75 2.2 Dimensions [mm] GAMMA unit series A B C D DE E F G K KA Q S Suction T Discharge Weight [kg] GAMMA 10 585 1005 435 320-980 710-200 - 269 DN40 DN50 220 GAMMA 20 670 1005 435 320-980 710-200 - 314 DN40 DN50 240 GAMMA 30 660 1090 435 355-1015 820-240 - 305 DN50 DN50 330 GAMMA 40 680 1090 435 355-1015 820-240 - 366 DN50 DN50 360 GAMMA 50 660 1550 335 1130 530 1375 915-320 - 385 DN100 DN100 570 GAMMA 60 610 1600 315 1130 533 1375 965-320 - 455 DN100 DN100 610 GAMMA 70 740 1855 400 1130 530 1795 1065-320 - 595 DN100 DN100 750 GAMMA 90 990 2190 495 1470 678 2030 1185 1745 280 380 605 DN200 DN125 1360 GAMMA 100 990 2325 495 1470 678 2030 1320 1745 280 380 740 DN200 DN125 1450 GAMMA 90 Container fit 895 2190 495 1470 678 2030 1185 1745 280 380 605 DN200 DN125 1450 GAMMA 100 Container fit 895 2325 495 1470 678 2030 1320 1745 280 380 740 DN200 DN125 1450 6

E D Ç A Ç DE K Q F C B Å S T DOC1611200B DE E E È GAMMA 10-40 D Q A F B K C T S DOC1611223B DOC1611223B GAMMA 50-70 Ç DOC1611200B GAMMA 90-100 Æ Å G D K KA C A Q F B AND / OR T S DOC1613105B GAMMA units 7 DOC1613105B

DE D G E DE G D E GAMMA 90-100 Container Fit Right C K KA A Q F B T S DOC1613108B DOC1613108B GAMMA 90-100 Container Fit Left C K KA Q F A B T S DOC1613109B DOC1613109B 8

2.3 Storage conditions If the temperature is below freezing point of the service liquid it may damage the pump. Under these conditions the pump must be drained completely or filled with anti freeze liquid. At storage for more than 30 days, see manual for: Electrical motor Liquid ring pump Liquid separator 4-way valve 2.4 Handling and transport The unit may not be used if it is damaged or the identification plate is missing! By fork-lift truck handling the unit can be transported in the original container or onto an approved EUR pallet. Handling with crane must only be made by hooking the unit s lifting eye loops. The weight of the respective GAMMA unit can be found on the nameplate. See Chapter 1.3 GAMMA 10-40 GAMMA 50-70 GAMMA 90-100 DOC1627223A DOC1627222A DOC1627221A The loop eye of the electrical motor may not be used for gripping by lifting the entire unit. DOC1627223A DOC1627222A DOC946000049_1A GAMMA units 9 DOC946000049_1A

The pump can be transported in the following ways: DOC11093A 2.5 Removal and disposal The most parts of the Samson GAMMA units can be recycled. Samson Pumps therefore offers the user of Samson GAMMA units the opportunity to return worn units for renovation or scrapping. For those who do not wish to make use of the offer of the factory, the GAMMA units after separation have to be separated into components. Worn GAMMA units can be separated into following components: Service liquid Gaskets Hoses Plastic Parts These parts are to be disposed according to national rules. The residue, consisting of metal components can be sent for re-melting. 10

3 INSTALLATION AND START-UP 3.1 Installation requirements 3.1.1 Anchoring The unit must be mounted onto a stable foundation, which has to be right and torsion stable, so that the pump/unit is not exposed to torsion. The pump/unit must be anchored with foundation bolts in all four legs. k 0,5mm 3.1.2 Electrical installation DOC1627331_1 Make sure power supply is disconnected before installing cables on motor! Electrical connections are made only by authorized personnel! Reference is made to the manual of the actual electrical motor. 3.1.3 Service liquid supply For units without liquid separator - see actual liquid ring pump manual. For units with liquid separator mounted - see liquid separator manual. GAMMA units 11

3.2 Prior to start-up Do not start the unit without service liquid, as this will damage the mechanical shaft seals. Do not start the unit if it is completely filled with service liquid. Do not start the unit before the grease cartridges have been activated, as this can damage the pump. Stop the unit immediately if the rotational direction does not correspond to the directional arrow. A failure to follow the above guidelines may result in damage to the unit. 3.2.1 Activating the grease cartridges Turn the knob on both grease cartridges clockwise to position 12. 3.2.2 Direction of rotation Check the direction of rotation by briefly starting the pump. The direction of rotation of the rotor must correspond to the direction arrow! If the direction of rotation is incorrect - the cause is an improper electrical connection. Please call authorized personnel for corrective action. DOC106946_1 3.2.3 Vacuum limiter If the unit is equipped with a vacuum limiter, make sure it is adjusted in accordance with the vacuum limiter manual. 3.2.4 Serial connection If the unit is included in an installation with multiple units in serial connection or connected to a vacuum tank. It is important that the outlet side of the unit is equipped with a Non-Return Valve. Without the Non-Return Valve, the other units might draw intake of false air through the actual unit when this is not in operation. 3.3 Start-Up Start the unit. Perform a visual inspection of unit for leakages, noise and vibrations. If any of those symptons are present, STOP the unit immediately! Start troubleshooting. 12

4 SERVICE, MAINTENANCE AND INSPECTION INTERVALS 4.1 Maintenance Do not perform any maintenance work on unit, while in use! 4.1.1 Transmission Check the pulley tension for every 5.000 hours of operation. The belt tension is controlled with the attached Belt Tester. Please read the manual carefully for the Belt Tester before the test is carried out. Diameter of the smallest pulley, mm Setting of the Belt Tester, when installing new belts Setting of the Belt Tester adjusted after an hour of operation Less than 160 650 N 500 N Between 160 and 224 700 N 550 N Between 224 and 355 900 N 700 N More than 355 Contact SAMSON PUMPS Contact SAMSON PUMPS 4.1.2 Lubrication of pump bearings Check the automatic lubrication cartridges every 3 months. If level of grease reaches zero, the cartridge must be replaced. When replaced, activator must be turned on position 12. Detailed instructions about pump, see manual for the actual liquid ring pump. 4.1.3 Lubrication of motor bearings See manual for the actual motor. 4.1.4 4-way valve (if equipped) Each grease nipple must be greased every 3 months, with 6-8 g of LGWA2 grease. GAMMA unit out of use for 30 days or more, must be greased before start. Detailed instructions about 4-way valve, see 4-way valve manual. 4.1.5 Liquid separator (if equipped) It is recommended that the liquid separator is emptied manually once a day by opening the drain valve. GAMMA unit out of use for 30 days or more, it is recommended to close the external water supply and to empty the liquid separator. Detailed instructions about liquid separator, see liquid separator manual. GAMMA units 13

5 SPARE PARTS 5.1 How to order When ordering spare parts, please indicate the desired position, as well as the type and number, which are indicated on the nameplate of the unit. See below. Electrical motor 1 6 Transmission V-belts 7 V-belt pulley motor Service liquid valve 2 8 Bush motor Vacuum limiter 3 Automatic lubricator 4 9 V-belt pulley pump Bracket for automatic lubricator 5 10 Bush pump 14

Notes: GAMMA units 15

SAMSON PUMPS Samson Pumps is the only company in the world to specialise exclusively in liquid ring vacuum pumps. Samson pumps are made in Denmark and used around the globe. We offer worldwide delivery, and we export to more than 80 countries around the world. For over 40 years, our name has been synonymous with the strongest pumps for vacuum trucks and tankers. We constantly adapt our products to meet the changing needs of our customers. Today, it is not enough to simply produce a pump. Products must be refined so the customer can concentrate on what they do best. We therefore offer a wide range of standardised components that allow our customers to build vacuum systems without the need for specialist in-house expertise. Strength and durability are our hallmarks! We have often heard from customers that our pumps are working in many years, and in most cases without the need for maintenance or repair. This emboldens us to say that we have the strongest program of pumps on the market. E-Mail info@samson-pumps.com Samson Pumps A/S Petersmindevej 21 Web www.samson-pumps.com Phone +45 87 50 95 70 DK-8800 Viborg